Home
FMI CGEF23B User's Manual
Contents
1. Mantel Installation Figure 3 Heater Locations INSTALLATION A WARNING RISK OF FIRE The power cord must not be pinched or against a sharp edge Secure cord to avoid tripping or snagging to reduce the risk offire electric shock or personal injury Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic areas and where it will not be tripped over A WARNING RISK OF FIRE To prevent a possible fire do not block air intake or exhaust in any manner Do not use on soft surfaces where openings may become blocked AA WARNING RISK OF FIRE Do not blow or place insulation against the firebox Awarnine If the information in these instructions is not fol lowed exactly a fire or explosion may result causing property dam age personal injury or death 120926 26C Do not store or use gasoline or other flammable vapors in the vi cinity of this or any other heater INSTALLING FIREPLACE Select a suitable location that is not suscep tible to moisture and is a safe distance from d rapes furniture and high traffic areas Note Follow all national and local electrical codes This insert can be installed into either a n existing fireplace or as new construction renovation Installing in Mantel 1 2 Assemble mantel according to mantel i
2. 30 Blower 2 120926 06 Rear Glass Screen 3 120926 05 Log Set 4 120926 07 Flame Effect Mirror 5 120926 32 Magnetic Catch 6 120926 09 Main Control Board and Standoffs 7 120927 10 Transformer 8 120927 11 Heater 9 120926 12 Settings Control Board 10 120926 13 LED Drum Assembly 11 120927 14 Motor Drum 12 120926 15 LED Ember Strip 13 120926 20 Remote Control 14 120927 21 Remote Control Sensor 15 120927 22 Power Cord 16 120927 24 ON OFF Switch 17 120926 03 Front Glass 18 120926 02 Control Panel Door Black 19 120926 25 Top Black 20 120926 04 Front Trim i PARTS AVAILABLE NOT SHOWN n ES BS oo Ee Ee Ee Ee Ee EE Ee Ee 120926 17 Wire Flame Effect 1 i 120926 18 Wire Ember Bed 1 120927 23 Thermocouple d 120926 26C www fmiproducts com 15 WARRANTY KEEP THIS WARRANTY Model located on product or identification tag Serial No located on product or identification tag Date Purchased Keep receipt for warranty verification FMI PRODUCTS LLC LIMITED WARRANTIES New Products Standard Warranty FMI PRODUCTS LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two 2 years from the date of first purchase from an authorized dealer provided the product has been installed maintained and operated in accordance with FMI PRODUCTS LLC s warnings and instructions For products purchased for commercial industrial or rental
3. 4 Extreme caution is necessary when any heater is used by or near children or inva lids and whenever heater is left operating and unattended 5 Always unplug heater when not in use 6 Do not operate any heater with a damaged cord or plug or if heater malfunctions or has been dropped or damaged in any way Return heater to authorized service facility for examination electrical or mechanical adjustment or repair 7 Do not use outdoors 8 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate heater where it may fall into a bathtub or other water container 9 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped over 10 To disconnect heater turn controls to the OFF before removing plug from outlet 11 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 12 To prevent possible fire do not block air intakes in any manner Do not use on soft surfaces like a bed where openings may become blocked 13 Always use properly grounded fused and polarized outlets 120926 26C SAFETY Continued 14 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids or vapors are used or stored 15 Use this heater only a
4. IF FMI PRODUCTS LLC 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4538 120926 26 www fmiproducts com Rev C P 09 09
5. center of unit just above log set IMPORTANT This remote control must remain within 20 feet 6 m of fireplace to be effective 5 When power switch is turned off fire place settings go back to default see Figure 7 page 8 HEATER Figure 6 Remote Control For Electric Fireplace www fmiproducts com T OPERATION Continued FLAME Off Low Medium CHigh gt EMBER Off Low Medium High HEATER Offon Figure 7 Fireplace Settings Default Settings are Circled CLEANING AND MAINTENANCE Control Panel Door AX WARNING Always discon nect power and allow the heater to cool before performing any cleaning maintenance or reloca tion of this heater Turn controls to OFF and remove plug from outlet or turn off circuit breaker to heater Screws To service electric fireplace it may be neces sary to remove it from the mantel or enclosure WN K Trim in which itis installed Let unit cool completely WN before cleaning or servicing SN Magnets on Back of Trim CLEANING FIREBOX U 1 Open control panel door by pressing on Figure 8 Removing Trim right side A spring magnet will push door forward Pull door down to open 2 Remove 2 screws holding front trim in Bracket place Pull gently to remove trim see Figure 8 There are magnets on the lower portion of trim see Figure 8 3 With gloves and safety glasses in place remove 4 screws from glass retainer brackets 2 p
6. in remote control 2 Not aiming control correctly 2 Aim control at sensor located directly behind glass screen in center of unit just above logs 3 Defective remote control 3 Replace remote control and and or sensor or sensor Fireplace willnotcomeonwhen 1 Fireplace is not plugged in 1 Check plug switch is flipped to ON to an electrical outlet 2 Control failure 2 Call a qualified service tech nician to replace control 3 Breaker tripped 3 Reset breaker Heater does not provide heat 1 Thermal switch has been 1 Turn unit off and unplug unit when turned on tripped for 5 minutes Plug back in and turn unit on If plug cannot be reached follow directions for tripped circuit breaker 2 Circuit breaker has been 2 Turn off circuit breaker that tripped supplies electricity to unit Wait 5 minutes then flip cir cuit breaker back on 3 Wiring is loose 3 Disconnect from power source and inspect wiring for loose connections and repair or replace if necessary 4 Heater is defective 4 Replace heater 5 Thermostat cycled off 5 Change to higher setting 120926 26C www fmiproducts com PARTS MODELS CGEF23B AND VEF21B 14 www fmiproducts com 120926 26C PARTS MODELS CGEF23B AND VEF21B This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Replacement Parts on page 12 of this manual NO PART NO DESCRIPTION QTY 1 120925
7. they can t supply original replacement part s call FMI PRODUCTS LLC at 1 866 328 4537 When calling have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory ACCESSORIES Purchase these accessories from your local dealer If they can not supply these accesso ries call FMI PRODUCTS LLC at 1 866 328 4537 for information You can also write to the address listed on back this manual 21 WALL MANTELS WITH BASE AND TRIM W21TU 21 Wall Mantel Unfinished Traditional W21TO 21 Wall Mantel Oak Stain Traditional 21 CORNER MANTELS WITH BASE AND TRIM C21TU 21 Corner Mantel Unfinished Traditional C21TO 21 Corner Mantel Oak Stain Traditional WIRING DIAGRAM 2 6 a lt 5 19 21 23 FIREPLACE CONTROL DIAGRAM E iS 3 Sry 8 a g u z PCB BOARD AND FUNCTION CONTROL ASSEMBLY 3 amp P N FF203 0014 9000 Rev A MO Peeps y i 0 g u WHITE nfe SENS 120v 650w 2 120v14W 24V5W 120V 4W 24V1W ON OFF POWER x oO 0 a BRW BLU BRW scl LDA MTR LDS RCS THM F Sado S OG u E i o T T a WHITE C BLACK BLOWER V33 BLACK BROWN HEATER a T ae ra Syn MOTOR ib i BROWN oo THERMOCOUPLE HEATER REMOTE amp
8. usage this warranty is limited to 90 days from the date of first purchase Factory Reconditioned Products Limited Warranty FMI PRODUCTS LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed maintained and operated in accordance with FMI PRODUCTS LLC s warnings and instructions Terms Common to All Warranties The following terms apply to all of the above warranties Always specify model number and serial number when contacting the manufacturer To make a claim under this warranty the bill of sale or other proof of purchase must be presented This warranty is extended only to the original retail purchaser when purchased from an authorized dealer and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product This warranty covers the cost of part s required to restore this product to proper operating condition and an allow ance for labor when provided by a FMI PRODUCTS LLC Authorized Service Center or a provider approved by FMI PRODUCTS LLC Warranty parts must be obtained through authorized dealers of this product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat
9. aining glass pieces with a shop vac DO NOT VACUUM WHILE PIECES ARE HOT Replace glass only with replacement part specifically for this heater Never substitute material Only fully tempered soda lime safety glass may be used on this heater 3 To access glass to clean or replace follow steps 1 and 7 under Replacing Flame Generation LED Set aside bottom panel 4 Remove screws securing log base to unit Carefully remove log base from unit 5 Using gloves gently remove glass panel by sliding it toward you There is a rubber bumper on each corner of glass 6 Clean glass as instructed in step 1 or replace glass 7 Using gloves reinstall glass by gently sliding smooth side toward fireplace front into brackets on either side that hold glass in place 8 Replace log base 9 Follow steps 11 and 14 under Replacing Flame Generation LED TECHNICAL SERVICE You may have further questions about instal lation operation or troubleshooting If so contact FMI PRODUCTS LLC at 1 866 328 4537 When calling please have your model and serial numbers of your heater ready This information is located on the inside of the control panel door Figure 2 page 4 You can also visit our web site at www fmiproducts com www fmiproducts com 11 REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealers of this product If
10. ard Remove screws holding heater blower to top panel see Figure 11 Remove brackets from heater blower see Figure 12 Save brackets and screws To remove heater from blower remove 4 screws 2 per side If replacing blower remove screws from brackets on blower Install brackets to new blower Replace blower or heater Replace screws removed in step 7 see Figure 13 page 10 Hold heater blower with brackets in place against top panel and replace screws removed in step 5 Reconnect wires to main circuit board see Wiring Diagram page 12 Replace top panel and screws 13 Replace trim Screws Securing Heater Blower Top Panel Screws Figure 11 Removing Top Panel and Heater Blower vs Bi Brackets P 8 Figure 12 Removing Brackets from Heater Blower www fmiproducts com 9 CLEANING AND MAINTENANCE Continued Heater Figure 13 Removing Heater from Blower REPLACING TRANSFORMER 1 Follow steps 1 through 3 under Replacing Heater Blower page 9 2 Disconnect transformer wires from control board 3 Remove screws from outside of firebox surround to remove transformer see Figure 14 4 Remove and discard transformer 5 Place new transformer against inside of firebox surround and replace screws removed in step 3 6 Reconnect transformer wires to control board see Wiring Diagram page 12 7 Replace top panel and screws 8 Replace trim Transformer Screws F
11. d the edge of the unit see Any new wiring must be done in compliance with local and national codes and other ap plicable regulations in order to reduce the risk of fire electric shock or other injuries Therefore it strongly recommended that you hire a professional to complete any Note The height that a combustible mantel is fitted above the heater is dependent on thea minimum of 1 such work above the front 4 Plan you power supply route See step 4 of Framing Figure 4 Framing Heater for New Construction Renovation 6 www fmiproducts com 120926 26C INSTALLATION Continued Installing as Insert Once the site has been prepared the fireplace insert can be installed 1 Make sure power switch is in the OFF position 2 Plug fireplace into a 15 amp 120 volt grounded outlet 3 Push fireplace insert so that the trim is against the finished mantle or wall surface FINISHING WARNING Control panel door on this heater cannot in any way be covered as it may create a fire hazard Combustible Finishing Material Materials made of or surfaced with wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or unplastered this includes drywall Noncombustible Finishing Material Ma terials which will not ignite and burn Such materials are those consisting entirely of steel iron brick tile concrete slat
12. dFmi FMI PRODUCTS LLC ELECTRIC FIREPLACE INSERT MODELS CGEF23B AND VEF21B SAFETY INFORMATION AND INSTALLATION MANUAL Patent No 7 219 456 B1 Read these instructions completely before beginning installation Failure to follow them could cause a heater malfunction resulting in serious injury and or property damage WARNING All electric heaters have hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are or are stored This fireplace meets the construction and safety stan dards of H U D for application in manufactured homes when installed according to these instructions INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference For more information visit www fmiproducts com TABLE OF CONTENTS DAICLY vececesedectveissnssuiswnventievevercesce dees rerss eae 2 Cleaning and Maintenance ccceeeeeeeeees 8 Listing Approvals 3 Technical Service wt Product Dimensions a3 Replacement Parts 12 Product Identification 4 Accessories 12 Unpacking and Testing 4 Wiring Diagram a12 Locating Fireplace 4 Troubleshooting 13 Installation wD PAWS sicccsse eccentric E 14 Finishing gil WAIT AUN Yess coon erence ce cestene goreseveaeeseasnctecs Back Page Operaatio issacacticstecesadeniwcvesesntedecceteceesazz recs ss
13. e glass or plasters or combinations thereof or have a fire rating of zero FINISHING CHECKLIST e Power supply service must be completed prior to finishing to avoid reconstruction e Grills and air openings cannot be covered in any circumstances Note The heater is a zero clearance fireplace and may be finished with combustible or non combustible finishing materials When using paint or lacquer to finish the mantel they must be heat resistant to prevent discoloration OPERATION The controls see Figure 5 are located behind hinged control panel door If using heater con trol panel door will be hot during and immedi ately after operation Open door by pressing on right side A spring magnet will push door forward Pull door down to open 1 Plug in electric fireplace 2 Turn on lighted power switch see Figure 5 3 Adjust Flame and Ember to desired set tings using the control pad on fireplace or remote control see Figure 6 Figure 7 page 8 shows fireplace settings available Default settings are circled Press control pad or remote control buttons once and release to adjust settings The heater works with a thermostat when turned on It will shut off when room reaches approximately 86 F 30 C Ember Control Heater Flame Ember Lighted Power Switch Figure 5 Controls For Electric Fireplace Flame Control Heater Control o 120926 26C 4 When using remote control aim remote at sensor located in
14. er bracket 4 Carefully remove front glass and brackets see Figure 9 5 Using a brush vacuum attachment gently clean compartment Screws a 6 After cleaning compartment replace front Front Glass Bracket glass screw bracket and trim Figure 9 Removing Brackets and Front Glass 8 www fmiproducts com 120926 26C CLEANING AND MAINTENANCE Continued REPLACING LOG 1 Follow steps 1 through 4 of_Cleaning Firebox page 8 2 Remove screws from each side of log that secures log to base and remove log see Figure 9 page 8 3 Install new log using screws removed in step 2 4 Replace front glass bracket and screws 5 Replace trim Ember LED Strip with Standoffs Log Figure 10 Removing Log and Ember LED REPLACING EMBER STRIP 1 Follow steps 1 and 2 under Replacing Log 2 Locate ember LED strip see Figure 10 Disconnect wire right side 3 Remove ember LED strip by squeezing top of standoffs and discard 4 Connect new ember LED strip using exist ing standoffs 5 Reconnect wire to LED strip 6 Follow steps 3 and 4 under Replacing Log REPLACING HEATER BLOWER 1 Follow steps 1 and 2 of Cleaning Firebox page 8 2 Remove screws from around top panel of firebox see Figure 11 3 There are several wires attached to the top panel Carefully lift top panel 120926 26C 4 5 10 11 12 Disconnect heater blower wires from main circuit bo
15. erial labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded from this warranty are products or parts that fail or become damaged due to misuse accidents improper installation lack of proper maintenance tampering or alteration s This is FMI PRODUCTS LLC s exclusive warranty and to the full extent allowed by law this express warranty excludes any and all other warranties express or implied written or verbal and limits the duration of any and all implied warranties including warranties of merchantability and fitness for a particular purpose to two 2 years on new products and 30 days on factory reconditioned products from the date of first purchase FMI PRODUCTS LLC makes no other warranties regarding this product FMI PRODUCTS LLC s liability is limited to the purchase price of the product and FMI PRODUCTS LLC shall not be liable for any other damages whatsoever under any circumstances including indirect incidental or consequential damages Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For information about this warranty contact
16. ers e Gloves cord can run along front of fireplace If Hammer e Level cord is not long enough to reach outlet a grounded extension cord minimum AWG No 14 and rated to a minimum of 1875 watts may be used If you plan to cut or drill Tape measure a hole in existing fireplace for wiring itis Wall finishing materials best to hire a professional to do this stepin Caulking material order to prevent personal injury To reduce A g the risk of fire do not run power cord under CAUTION Provide adequate rugs carpets etc Arrange power supply clearances around the air open cord away from high traffic areas where it ings and adequate accessibility may pose a tripping hazard clearances for servicing and WARNING The solidfuel gas Proper operations fireplace has been converted for use with an electric insert and cannot be used for original fuels unless all original parts have been replaced and the fireplace has been reapproved by the au thority having jurisdiction e Phillips screwdriver e Surround e Framing materials e Electric drill bits New Construction or Renovation 1 Select a location at least 3 feet 0 9 m Header away from combustible materials such Height as curtains or drapes furniture bedding paper etc 2 Mark desired location on floor and store unit in a safe dry and dust free location 3 Frame in an opening leaving at least 1 4 6 mm aroun
17. ews from sides and back of bottom panel of firebox 4 Gently lay unit on its back 5 There are several wires attached to bot tom panel Carefully remove panel 6 Disconnect wires from motor and LED drum assembly 7 Remove screws from bottom panel to remove assembly 8 If motor on assembly fails loosen clamps see Figure 17 Remove screws from motor Hold universal joint while removing motor and discard 9 Install new motor Slide motor shaft into universal joint and tighten clamps 10 Hold LED drum assembly in place on bottom panel and replace screws 11 Reattach wires to motor and LED drum Note LED drum wires are polarity sensi tive and must be connected correctly White wire plugs onto left terminal and red wire plugs onto right terminal Motor wires can be connected to either terminal LED Drum Assembly Figure 17 Flame Generation LED Drum Assembly 120926 26C 12 Replace fireplace bottom panel Set fire place upright and replace screws 13 Replace log glass and bracket 14 Reinstall fireplace and replace trim CLEANING OR REPLACING BACK SCREEN GLASS 1 The glass is cleaned in the factory during assembly During shipment installation handling etc glass surface may collect dust particles These can be removed by buffing lightly with a clean damp cloth water only Glass should be completely dried with a lint free cloth or paper towel 2 Inthe event of glass breakage vacuum all rem
18. igure 14 Removing Transformer REPLACING MAIN CONTROL BOARD 1 Follow steps 1 through 3 under Replacing Heater Blower page 9 2 Disconnect wires to main control board 3 Squeeze top of standoffs to remove main control board and discard 4 Gently push new control board onto standoffs to install 10 www fmiproducts com 5 Reconnect wires to main control board see Wiring Diagram page 12 6 Replace top panel and screws 7 Replace trim Main Control Board A ale Y Transformer Figure 15 Control Board REPLACING SETTINGS CONTROL BOARD 1 Follow steps 1 through 3 under Replacing Heater Blower page 9 2 Disconnect wires from main control board 3 Remove screws from bracket to remove settings control board 4 Place new settings control board into posi tion making sure each control is aligned with slot in panel Install using screws from step 3 DO NOT overtighten This will damage control board 5 Reconnect wires to main control board see Wiring Diagram page 12 6 Replace top panel and screws 7 Replace trim A Pi Screws Settings Control Board Figure 16 Replacing Settings Control Board 120926 26C CLEANING AND MAINTENANCE Continued REPLACING FLAME GENERATION LED 1 Follow steps 1 through 4 under Cleaning Firebox page 8 2 Remove screws from each side of log that secures log to base and remove log see Figure 10 page 8 3 Remove scr
19. niuetactees 7 SAFETY WARNING Improperinstalla tion adjustment alteration ser vice or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer A CAUTION Donotexpose the heater to the elements such as rain etc Do not place clothing or other flammable material on or near firebox Never place any objects on the fireplace Carefully supervise young chil dren when they are in the room with fireplace Fireplace becomes very hot when running Keep children and adults away from hot surfaces to avoid burns or clothing ignition Fireplace will remain hot for a time after shutdown Allow sur faces to cool before touching Do not install fireplace directly on carpet or similar surface which may restrict air circulation beneath unit When using electrical heaters basic precau tions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 2 www fmiproducts com 1 Read all instructions before using this heater 2 Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9 m from front of heater 3 This heater is hot when in use To avoid burns do not let bare skin touch hot surfac es The grill directly in front of heater outlet becomes hot during heater operation
20. nstructions Locate mantel near a wall or corner depending on mantel type close to a power source You may have to alter base boards to fit mantel flush against wall Insert fireplace into front of mantel Be careful not to scratch finish on base Fire place will fit flush against front of mantel Plug fireplace into power source Push mantel with fireplace into final location Existing Fireplace Installation Thoroughly clean out existing fireplace and hearth area Seal all drafts vents or ash clean outs with fiberglass insulation Seal flue Once sealed close damper to stop debris from falling onto unit If existing fire box is susceptible to mois ture cap top of chimney flue to prevent infiltration of water www fmiproducts com 5 INSTALLATION Continued Note It is strongly advised that you hire a Framing qualified professional to undertake this step Figure 4 shows a typical framing of this heater in order to prevent personal injury Once the using combustible materials All required flue is capped chimney is no longer suitable clearances to combustibles must be adhered for wood burning to Header height is measured from the base Note Do not install this unit into a fireplace of the heater that is prone to dampness the area ofinstal Tools and building supplies required for lation must be dry installation 4 Plan the power supply If an existing Saw e Square grounded outlet is near fireplace power Pli
21. on LED 4 SENSOR Q x POWER CORD SETS HEATER BLOWER g ASSEMBLY Ma LED EMBER STRIP MF500 12 www fmiproducts com 120926 26C TROUBLESHOOTING A WARNING Turn off appliance and let cool before servicing Only a qualified service person should service and repair heater OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Fireplace turns off and will not turn on 1 Fireplace has overheated and safety devise has cause thermal switch to disconnect or home circuit breaker has opened f Reset switch by turning main power switch off and waiting 5 minutes then turning it back on or reset circuit breaker Flame is not moving 1 Loose wiring Inspect wiring for loose connections 2 Flame motor defective 2 Call a qualified service techni cian to replace flame motor Flame is not visible 1 Wiring is loose 1 Disconnect from power source and inspect wiring for loose connections and repair or replace if necessary Log set and or ember is not 1 Wiring is loose 1 Disconnect from power glowing source and inspect wiring for loose connections and repair or replace if necessary Flame sputters flashes 1 Flame motor is defective 1 Call a qualified service techni cian to replace flame motor 2 Flame generation contacts 2 Disconnect power Follow dirty obstructed steps to replace flame gen eration LED Clean contacts with dry cloth Remote control does not work 1 Low batteries 1 Replace AAA batteries
22. peratures this heater should be located out of traffic Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9 m from the front of the heater NOTICE Minimum and maximum clearances mustbe maintained at alltimes Illustrations throughout these instructions reflect typical installations and are for design purposes only Actual installa tions may vary slightly due to individual preferences A WARNING Never locate this heater where it may fall into a bath tub or other water container AL WARNING To prevent contact with sagging or loose insulation the heater must not beinstalled against vapor barrier or exposed insulation Localized overheating could occur and a fire could result www fmiproducts com 120926 26C LOCATING FIREPLACE Continued A CAUTION Do not expose the heater to the elements such as rain etc A CAUTION Wear gloves and safety glasses for protec tion during installation and maintenance This electric fireplace can be installed in a mantel framed into a wall or installed into an existing fireplace If installing into a mantel follow mantel s assembly instructions Figure 3 illustrates a variety of ways the heater may be located in a room The heater may be installed directly on the floor or raised on a hearth Corner Installation Framed Into Wall or Existing Fireplace
23. rounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the Cana dian Electric Code CSA C22 1 as appropriate PRODUCT DIMENSIONS 19 23 NI Y i 17 Figure 1 Heater Dimensions 120926 26C www fmiproducts com 3 PRODUCT IDENTIFICATION Control Panel Door Heat Vents Behind Door Front Glass 1T Back Glass Remote Log Set Figure 2 Product Handle lame Heater Control Control Ember Control ON OFF Power Button Heater Fiame Ember Thermocouple Identification UNPACKING AND TESTING Carefully remove unit from box Prior to permanently installing unit test to make sure unit operates properly To do this plug unit s power supply cord into a conveniently located 120 volt grounded outlet A CAUTION The unit s power supply cord must be connected to a properly grounded and pro tected 120 volt outlet Always use ground fault protection where required by the electrical code AX WARNING Do not operate the unit if it is damaged or has malfunctioned If yoususpectthe unit is damaged return the unit to an authorized service facility for examination electrical or me chanical adjustment or repair LOCATING FIREPLACE A WARNING Due to high tem
24. s described in this manual Any other use not recommended by the manufacturer may cause fire elec tric shock or injury to persons 16 Avoid the use of an extension cord be cause the extension cord may overheat and cause a risk of fire However if you have to use an extension cord the cord should be No 14 AWG minimum size and rated not less than 1875 WATTS 17 Always use ground fault protection where required by electrical codes 18 Always disconnect power before perform ing any cleaning maintenance or reloca tion of heater 19 To prevent a possible fire do not burn wood or other materials in this heater 20 To prevent electric shock or fire always use a certified electrician should new circuits or outlets be required 21 When transporting or storing heater keep in a dry place 22 Control panel door gets hot during opera tion Open door by pressing on right side Aspring magnet will disengage Pull door down to open LISTING APPROVALS This heater has been tested in accordance with the CSA Standards for fixed and location dedicated electric room heaters in the United States All components are UL or CSA safety certified If you need assistance during installation please contact your local dealer or the FMI PROD UCTS LLC at 1 866 328 4537 Description 23 Fireplace Insert Voltage 120 Watts 1500 Amps 15 Amp Grounded Circuit Note This heater must be electrically wired and g
Download Pdf Manuals
Related Search
Related Contents
第一種フロン類充塡回収業者登録申請要領 JARDUINO MANUAL DE USUARIO v1.2 beta 11# í *** Dir 33888 Busc 6 d #21# í # í #22# í #10# í #23# í # í #001# í 「スコール」【R型制御盤の場合】(PDF:418KB Copyright © All rights reserved.