Fluke PN 3612805 User's Manual
Contents
1. ghl004 eps 373 Users Manual ghl005 eps 12 Clamp Meter The Meter 373 Users Manual Clamp Meter The Meter Electrical Specifications AC Current Range 600 0 A Resolution 0 1A PAC CUNACY ria 2 96 5 digits 48 62 Hz Crest Factor 50 60 Hz 2 5 600A AC Voltage iege iaia 600 0 V Resol vivia arica 0 1V ACCUFACY iii 1 0 5 digits 48 62 Hz DC Voltage Range pem c 600 0 V Resolution 0 1V fool anA 1 5 digits Resistance Range ee en aan 600 0 9 6000 Q Resolution uei eene pes 0 1 0 1 Q 15 373 Users Manual ACCURACY siconecoceavieecancensereestunroeteanepncentecies 1 5 digits Continuity Beeper 300 Capacitance Range P denn 10 0 100 0 uF 1000 uF Resolution conica scents 0 1 uF 1 uF CCUFACY i 1 9 2 digits Mechanical Specifications Size Lx W XH nennen 232 mm x 85 mm x 45 mm Weight ir reete rice t 370g Environmental Specifications Operating Temperature 10 C to 50 C Storage TeMP i 40 C to 60 C Operating Humidity eee Non condensing 10 C 90 RH at 10 C to 30 C 75 RH at 30 C to 40 C 45 RH at 40 C to 50 C Without Condensation 16 Clamp Meter The Meter Operating Altitude
2. 373 A Clamp Meter PN 3612805 July 2010 2010 Fluke Corporation All rights reserved Printed in Taiwan Specifications are subject to change without notice All product names are trademarks of their respective companies LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke s behalf To obtain service during the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages this limitation of liability may not apply to you Fluke Corporation Fluke Europe B V P O Box 9090 P O Box 1186 Everett WA 98206 9090 5602 BD Eindhoven U S A The Netherlands 11 99 Table of Conte
3. 3000 meters Storage Altitude ereen 12 000 meters EMI EMC uses Meets all applicable requirements in EN61326 1 2006 Temperature Coefficients Add 0 1 x specified accuracy for each degree C above 28 C or below 18 C Safety Compliance s ANSI ISA S82 02 01 2004 CAN CSA C22 2 No 61010 1 04 IEC EN 61010 1 2001 600V CAT III 300V CAT IV Pollution Degree 2 EN IEC 61010 2 32 2002 EN IEC 61010 031 2002 A1 2008 CE Agency Approvals Ge Batteries cin yas ein 2 AA NEDA 15A IEC LR6 17 373 Users Manual 18
4. apply more than the rated voltage as marked on the Meter between the terminals or between any terminal and earth ground When using the probes keep fingers behind the finger guards on the probes 373 Users Manual Connect the common test lead before connecting the live test lead When disconnecting test leads disconnect the live test lead first Do not work alone so assistance can be rendered in an emergency Use extreme caution when working around bare conductors or bus bars Contact with the conductor could result in electric shock Adhere to local and national safety codes Individual protective equipment must be used to prevent shock and arc blast injury where hazardous live conductors are exposed Disconnect circuit power and discharge all high voltage capacitors before you measure resistance continuity or capacitance Do not measure current in circuits carrying more than 600 V or 600 A with the Meter Jaw Never operate the Meter with the back cover removed or the case open ACaution To avoid possible damage to the Meter or to equipment under test Use the proper jacks function and range for the measurement application Clean the case and accessories with a damp cloth and mild detergents only Do not use abrasives or solvents Make sure all water is removed before use Clamp Meter Safety Information Table 1 Symbols AC Alternating Current Earth ground Do not dispose of this product as unsorted munici
5. l shock or personal injury follow these guidelines Use the Meter only as specified in this manual or the protection provided by the Meter can be compromised Examine the case before you use the Meter Look for cracks or missing plastic Carefully look at the insulation around the connectors Never measure ac current while the test leads are inserted into the input jacks Make sure the battery door is closed and latched before operating the Meter Clamp Meter Safety Information Remove the test leads from the Meter before the battery door is opened Examine the test leads for damaged insulation or exposed metal Check test lead continuity Replace damaged test leads before using the Meter Do not use the Meter if it operates incorrectly Protection can be compromised When in doubt have the Meter serviced Do not use the Meter around explosive gas vapor or in damp or wet environments When measuring keep fingers behind the Tactile Barrier See The Meter 1 Use only type AA batteries properly installed in the Meter case to power the Meter To avoid false readings that can lead to electrical shock and injury replace the batteries as soon as the low battery indicator G _J appears When servicing the Meter use only specified replacement parts Have the Meter serviced only by qualified service personnel Be careful around voltages gt 30 V ac rms 42 V ac peak or 60 V dc Such voltages pose a shock hazard Do not
6. nts Title Page Introduction atri a ea Nea 1 How to Contact Fluke sen io 1 Safety Information 5 1o oo lane allea i ii 2 The Meter axo Electrical Specifications 15 Mechanical Specifications 16 Environmental Specifications sse nnne 16 373 Users Manual Introduction AAWarning Read Safety Information before you use the Meter The Fluke 373 Clamp Meter the Meter measures true rms ac and dc voltage ac current resistance and capacitance How to Contact Fluke To contact Fluke call one of the following telephone numbers e Technical Support USA 1 800 44 FLUKE 1 800 443 5853 e Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 e Canada 1 800 36 FLUKE 1 800 363 5853 e Europe 31 402 675 200 e Japan 81 3 3434 0181 Singapore 65 738 5655 e _ Anywhere in the world 1 425 446 5500 373 Users Manual Or visit Fluke s website at www fluke com To register your product visit http register fluke com To see print or download the latest manual supplement visit http us fluke com usen support manuals Safety Information A Warning identifies conditions and actions that pose hazard s to the user A Caution identifies conditions and procedures that could cause Meter damage equipment under test damage or permanent loss of data Symbols used on the Meter and in this manual are explained in Table 1 AAWarning To prevent possible electrica
7. pal waste Go to Fluke s website for recycling information DC Direct Current A Hazardous voltage C Conforms to European Union directives Risk of Danger Important Conforms to relevant North American E See Manual ee Standards em Batey Double insulated insulated Examined and licensed by T V Conforms to relevant Australian Product Services m standards 373 Users Manual IEC Measurement Category III IEC Measurement Category IV CAT III equipment has protection CAT IV equipment has protection against transients in equipment in against transients from the primary fixed equipment installations such CAT IV supply level such as an electricity as distribution panels feeders and Meter or an overhead or short branch circuits and lighting underground utility service Systems in large buildings CAT III Application around and removal from HAZARDOUS LIVE conductors is permitted Note The Measurement Category CAT and voltage rating of any combination of test probe test probe accessory current clamp accessory and the Meter is the LOWEST rating of any individual component Clamp Meter The Meter The Meter Clamp Meter CLAMP METER E R ghl008 eps 373 Users Manual Auto Off ghl001 eps Clamp Meter The Meter Backlight ghl002 eps 373 Users Manual ghl003 eps Clamp Meter The Meter
Download Pdf Manuals
Related Search
Related Contents
APRC55BK – Portable radio/CD player 10 = entretien final - Centre hospitalier universitaire (CHU) de RomiApex™ A-15 Lire tout l`article au format PDF Aides familiaux et aides soignants Samsung 32" LCD SyncMaster 320MX-3 LH32HBPLBC/EN Bruksanvisning Panasonic KX-TS4300 user manual Manuel d`utilisation Tecumseh AJA7455ZXA Drawing Data Copyright © All rights reserved.