Home
Fluke Impact Driver PN 650454 User's Manual
Contents
1. For safety use exact replacement Specifications Accuracy is specified for a period of one year after calibration at 18 C to 28 C 64 F to 82 F with relative humidity to 90 AC conversions are ac coupled average responding and calibrated to the RMS value of a sine wave input Accuracy specifications are given as of reading number of least significant digits Maximum Voltage Between 600 V any Terminal and Earth Ground Display Digital 3 200 counts updates 2 5 sec Analog 31 segments updates 25 sec Response Time of Digital Vac lt 2s Display Vdc lt i1s Q lt 1 s to 320 KQ lt 2s to 3 2 MQ lt 10 s to 32 MQ Operating Temperature 0 C to 50 C Storage Temperature 40 C to 60 C Temperature Coefficient 0 1 x specified accuracy C _ lt 18 C or gt 28 C Electromagnetic Compatibility in RF field of 3 V m on all functions except MQ Relative Humidity except 32 MQ Range 32 MO Range only Altitude Battery Type Battery Life Continuity Beeper Shock Vibration Size H x W x L Weight Safety EMC Regulations Certifications Listings G Sicherheit TUV PRODUCT SERVICE Total accuracy Specified accuracy plus 2 0 of range for all functions except 320 0 mV range total accuracy specified accuracy 1 0 of range 320 002 range total accuracy specified accuracy 8 of range 0 to 90 0 C to 35 C 0 to 70 35 C to 50 C 0 to 80
2. 0 C to 35 C 0 to 70 35 C to 50 C Operating 2000 meters Storage 12 000 meters 9 V NEDA 1604 or 6F22 or 006P or NEDA 1604A or 6LR61 2000 hrs typical with alkaline 1600 hrs typical with carbon zinc 4096 Hz per MIL T PRF 28800F Class III Sinusoidal Non Operating 2 8 cm x 7 5 cm x 16 6 cm 1 12 in x 2 95 in x 6 55 in 340 g 12 0 oz 600 V CAT II per ANSI ISA S82 01 1994 EN 61010 1 1993 CSA C222 No 1010 1 92 UL 3111 1 EN 61326 1 1997 CEE Function Range Accuracy ly 3 200 V 32 00 V 320 0V 0 3 1 600 V 0 4 1 mV 320 0 mV 0 3 1 V 45 to 500 Hz 3 2V 3 200 V 32 00 V 2 2 range Other ranges 45 320 0 V 600 V 2 2 to 1 kHz 0 320 0 O 0 5 2 3200 Q 32 00 kQ 0 5 1 320 0 kQ 3 200 MQ 0 5 1 32 00 MQ 2 1 gt nn 2 0V 1 typical Function Range Accuracy Typical Burden Voltage A 45Hzto 32 00 mA 320 0mA 2 5 2 6 mV mA 1 kHz 10 00 A 2 5 2 50 mV A 73 only 32 00 mA 320 0 mA 1 5 2 6 mV mA 73 only 10 00 A 1 5 2 50 mV A 10 A continuous 20 A for 30 seconds maximum Overload protection for all functions and ranges 600 V Function Input Impedance Nominal V mV V gt 10 MQ 50 pF Common Mode Normal Mode Rejection Ratio 1 Rejection kQ Unbalanced V mV 2120 dB at dc 50 Hz gt 60 dB at 50 Hz or 60 Hz or 60 Hz V gt 60 dB dc to 60 Hz Open Circuit Test Full Scale Voltage Vol ot
3. FLUKE 70 73 Series Ill Multimeter Instruction Sheet A Read First Safety Information To e ensure that the meter is used safely follow these instructions Never use the meter if the meter or test leads look damaged Be sure the test leads and rotary switch are in the correct position for the desired measurement Never measure resistance in a circuit when power is applied Never touch the probes to a voltage source when the test leads are plugged into the 10 A or 300 mA input jack To avoid damage or injury never use the meter on circuits that exceed 4800 volt amps Never apply more than the rated voltage between any input jack and earth ground Be careful when working with voltages above 60 V dc or 30 V ac rms Such voltages pose a shock hazard Keep your fingers behind the finger guards on the test probes when making measurements A Warning To avoid false readings which could lead to possible electric shock or personal injury replace the battery as soon as the battery indicator E appears Symbols A Read First Safety Information Manual Range or Automatic Touch Holde mode 5 Double Insulation CAT Il Overvoltage Installation Category per IEC 1010 1 Typical CAT Il locations include main wall outlets local appliances and portable equipment PN 650454 August 1997 Rev 2 2 98 91 997 1998 Fluke Corporation All rights reserved Printed in U S A All product names are trademarks of their respective c
4. age To3 2MQ 32M2 0 3 1 V dc 440 mV dc 1 4 V dc 2 8 V dc typical 420mVdc 1 3 V dc typical typical gt t ul 3 1 V dc 2 0 V dc Typical Short Circuit Current n 400 uA ull 500 pA gt Ve Typical Test Current 0 0V 0 5 mA 0 6V 0 4 mA 1 2V 0 3 mA 2 0 V 0 1 mA
5. nd protects the meter and comes with a Flex Stand To protect the front of the meter put the meter face down in the holster hri5f eps Maintenance A Warning To avoid electric shock remove the test leads before opening the case and close the case before using the meter To prevent fire and possible arc flash use fuses with ratings shown on the back of the meter Caution To avoid damaging meter components lift up the end of the battery as shown To avoid contamination or static damage do not touch the circuit board without proper static protection Internal Fuse Test RO 300 mA 10A 5 8 OQ E OK 0 5 2 OK 06 00 oL 68 oL 68 hr10f eps Battery and Fuse Replacement Note Before opening the case make sure the test leads are removed and the rotary switch is turned to OFF hriif eps Cleaning To clean the meter use a damp cloth and mild detergent do not use abrasives or solvents on the meter Service and Parts For service information in the U S A and Canada call 1 800 44 FLUKE 1 800 443 5853 in Europe 31 40 267 8200 from other countries 1 425 356 5500 Item Description Fluke Quan PN BT1 Battery 9 V NEDA 1604 IEC 6F22 or 696534 1 NEDA 1604A IEC 6LR61 614487 F1 Fuse F630 mA 250 V Min Interrupt 740670 1 Rating 1500 A IEC 127 1 F2 Fuse F11 A 1000 VAC DC Min 943118 1 Interrupt Rating 17 kA
6. ompanies Input Jacks Amps Volts Ohms Diode Test nere E BL Milliamps Common Terminal hr2f eps See Specifications for overload protection Pushbutton Use the pushbutton to either select a fixed range or put the meter in the Automatic Touch Holde mode Autorange The meter defaults to autorange when first turned on Manual Range Manual ranging is available in V ac V dc ohms A ac and A dc Ber nd Ei Varin n urn mr nnn LS Lat if LATA Lut ul Gr omeia E hr14f eps To return to autorange press D for 1 second or turn the rotary switch Automatic Touch Hold Mode A Warning To avoid electric shock do not use the Touch Holde to determine if a circuit with high voltage is dead The Touch Holdo mode will not capture unstable or noisy readings The Touch Holde mode automatically captures and displays stable readings Press C for 2 seconds while turning the meter on v DC c3 v pc O ZAIDA V V V 5 eoa YD AT single beep t hr3f eps When the meter captures a new input it beeps and a new reading is displayed To manually force a new measurement to be held press C 2 Note Stray voltages can produce a new reading To exit the Touch Holde mode turn the meter off Bar Graph The bar graph shows readings relative to the full scale value of a di
7. splayed measurement range and indicates polarity hr16f eps Standby If the meter is on but is inactive for an hour 20 minutes in diode test the screen goes blank and displays selected bar graph segments To resume operation turn the rotary switch or press O AC and DC Voltage Y Y mV Volts AC Volts DC Millivolts DC Dr tat ea iH 12g i c hr4f eps Resistance 0 Turn off the power and discharge all capacitors An external voltage across a component will give invalid resistance readings hr6f eps Diode Test Good Diode Good Diode Forward Bias Reverse Bias Bad Diode Bad Diode Shorted hr7f eps Continuity Test 1 hr5f eps If continuity exists resistance lt 210 Q the beeper sounds continuously The meter beeps twice if it is in the Touch Holde mode Current A A A Warning To avoid injury do not attempt a current measurement if the open circuit voltage is above the rated voltage of the meter To avoid blowing an input fuse use the 10 A jack until you are sure that the current is less than 300 mA Turn off power to the circuit Break the circuit For circuits of more than 10 amps use a current clamp Put the meter in series with the circuit as shown and turn power on hr8f eps Holster The snap on holster absorbs shocks a
Download Pdf Manuals
Related Search
Related Contents
デジタル機器の再スキャン手順 ※既に地上デジタル 12ch(リモコンの romÂnĂ/Moldovenească ҚАЗАҚША РУССКИЙ DEUTSCH ENGLISH Honeywell HHT290WHD Use and Care Manual Mitsubishi Electronics MSZ-FD09/12NA User's Manual Closet Maid S16GDW10 User's Manual Samsung 720B Kasutusjuhend Cisco PIX 515E Active/Active Failover 6-port Fast Ethernet Bundle パーソナルコンピュータ Let`sNote(紙マニュアル) TE-905 service manual.cdr Télécharger la fiche technique Copyright © All rights reserved.