1. omm standard height door extension height of upper panel 15 s 398mm standard height door extension height of upper panel 0 recommended Width of ALL the Panels Adjacent Cabinetry Upper Panel Toe Kick Panel g Front View of DishDrawer x v aan A oe open IP li Top of door must not overlap cabinetry 3 99 A2 2 5mm 32 316 5mm CLEARANCE _ MINIMUM CLEARANCE Countertop Y Countertop 5 64 2mm Tabs 32 u 3A 819 5 879 5mm Height of DishDrawer 2815 6 735mm Height of Toe Kick Panel 19 45 12mm MINIMUM CLEARANCE HEIGHT OF LOWER PANEL Measure door drawer height or equivalent and write it in the first box below then complete the equation For example c 30 762mm 155 398mm 54g 8mm 146 356mm height of upper panel height of lower panel r J l MIN 2814 717 5mm height of lower panel 1217 g4 311 5mm MIN ee Side View of DishDrawer air gap height of upper panel gap between panels Note The Door Extension B allows for the top of the Upper Panel to be above the DishDrawer where required Important The air vent between the Upper and Lower Panels must not be covered An air gap of 9 15 8mm MUST be provided BEFORE YOU START DishDrawer INTEGRATED PANEL THICKNESS Upper and Lower Panel minimum thickness is 94 16mm
2. PLEASE NOTE Your model of DishDrawer may differ from the model shown in the diagrams Diagrams have been simplified to enable clearer instruction FOLLOW THESE INSTRUCTIONS BEFORE REFERRING TO PRODUCT INSTALLATION INSTRUCTION SHEET P N 526607 BEFORE YOU START op of door must not 7 overlap cabinetry O l t3 o 32 2 5mm 32 2 5mm 3 4 5mm 5mm MINIMUM Width of the Panel MINIMUM MINIMUM MIN J CLEARANCE CLEARANCE rs 3 16 5mm Countertop Countertop MINIMUM CLEARANCE Adjacent Cabinetry Panel lai 3 n Front View of DishDrawer noe Side View of DishDrawer _ iy A Adjacent A Canine Cabinetry AN WARNING The Door of the DishDrawer Installer must leave can be made to match your 3 9mm gap for Be sure the Product Kitchen cabinetry This diagram correct ventilation is not plugged in with the addition of your own measurements will help you calculate the required panel sizes WIDTH OF THE PANEL HEIGHT OF THE PANEL Measure A the width between adjacent door drawer fronts and write it Measure door drawer height or equivalent and write it in the first in the first box below then complete the equation box below then complete the equation For example A 241 616mm 2 x 349 2 5mm 24146 611mm For example 8 16 407mm 3 9mm 15 398mm door clearance panel width air gap panel height to x J J e LO door
3. Panel A WARNING thicknesses above 1146 18mm can be accommodated but product depth BE SURE THE PRODUCT IS NOT PLUGGED IN will increase accordingly INTEGRATED PANEL MATERIAL Important Drawer Front material must be suitable for damp conditions The installation of the Panels requires an electrical 122 F 50 C 80 RH and adequately sealed to withstand moisture connection and must be performed by a suitably Additional protection can be provided by using a Moisture Resistant qualified person Board Taping edges alone may not provide adequate sealing For painted panels radius all rear edges to improve sealing TOE KICK PREPARATION WIDTH OF TOE KICK PANEL TOE KICK OPTIONS Refer to Width of All Panels on page 1 A The Black Prefinished Toe Kick Panel is supplied Refer to Installation Instructions for preparation B The Black Prefinished Toe Kick Panel can also have a front panel of HEIGHT OF TOE KICK PANEL your choice attached to it using screws or an adhesive HEIGHT OF TOE KICK PANEL C A Toe Kick panel of any material with thickness from 34 34 Refer to the diagram on page 1 Measure the height from the top of the 9 19mm can be screwed to a plastic Toe Kick Mounting Bracket adjacent cabinet door fronts to the floor and write it in the first box below supplied then complete the equation For example TOE KICK PANEL INSTALLATION DEPTH When using a rectangular Toe Kick the maximum depth excluding th
4. Bracket after REMOVE LOWER MOUNTING BRACKET TAB Panel has been secured Using six of the 16mm screws supplied secure the Mounting Bracket to each Panel at the six points shown in the diagram NOTE If the the six outermost slots are not able to be used to securely fix the Mounting Brackets to the Panel choose any six well spaced slots about the Panel PANEL PREPARATION INSTRUCTIONS DishDrawer STEP 5 SECURING THE TOE KICK PANEL NOTE If using the supplied Black Prefinished Toe Kick Tahal 5 proceed to Step 6 Grounding the Mounting Brackets and oles 5 Connecting the Badge Wires Place Toe Kick Panel face down on a soft surface and mark a vertical Toe Kick center line Panel Centralize the plastic Mounting Bracket on top of the Toe Kick Panel Align the top of the Bracket with the top of the Panel Using 5 of the 3 16mm screws provided fix the Mounting Bracket to the Toe Kick Panel Toe Kick Mounting Bracket STEP 6 GROUNDING THE MOUNTING BRACKETS AND CONNECTING THE BADGE WIRES Z WARNING Be sure the Product is not plugged in ii WH nL 1 Plug the green Badge grounding wire onto a Mounting Bracket tab le a ee tT Plug the grounding wire from the Product onto the other Mounting i 3 AT Bold Bracket tab gt 2 Connect the Badge plug to the top of the Badge Isolator Box Important The Badge Isolator Board is an electrostatic sensitive devi
5. clearance panel width gap between panel height 3 39 2 5mm MIN 23 Whe 595mm MIN panels 15 g 398mm MIN Note When the top of the DishDrawer has to be lower than the adjacent cabinetry the Panel can be increased in height Z WARNING The air vent between the Panel and the adjacent cabinetry must not be covered An air gap of 3 9mm MUST be provided BEFORE YOU START DishDrawer Use this diagram if installing the DishDrawer near floor level Countertop Countertop Te Cabinetry Cabinetry Drawer Front gt Drawer Top of Front T Toe Kick 8 Front view of DishDrawer Side view of DishDrawer IMPORTANT INTEGRATED PANEL THICKNESS WARNING Panel minimum thickness is 16mm Panel thicknesses above 18mm can ENSURE THE PRODUCT IS NOT PLUGGED IN be accommodated but product depth will increase accordingly INTEGRATED PANEL MATERIAL Drawer Front material must be suitable for damp conditions Important Additional protection can be provided by using a Moisture Resistant connection and must be performed by a suitably Board Taping edges alone may not provide adequate sealing For painted panels radius all rear edges to improve sealing qualified person PARTS SUPPLIED INTEGRATED PARTS KIT part no 526675 INTEGRATED PANEL PREPARATION BOOKLET i rl Integrated Rectangular Badge 1 Satin Chrome supplied Panel Panel p n 526975 Mounting Brac
6. EPARATION INSTRUCTIONS DishDrawer STEP 3 FITTING THE HANDLE AND BADGE FITTING THE HANDLE Fit the customer supplied handle N WARNING When mounting the handle be sure fastenings do not protrude beyond the back surface of the Panel FITTING THE BADGE Fit a Badge to each Panel by feeding the wires through to the back and pressing the Badge into the cut out If needed adhere the Badge to the Panel with an adhesive Feed the Badge wires through the slot in the Mounting Bracket As the Mounting Bracket is placed on the rear of the Panel the excess wire must be pulled through STEP 4 SECURING THE MOUNTING BRACKETS UPPER MOUNTING BRACKET Each Mounting Bracket is directly screwed to the back of each Integrated Panel On a soft surface centralize and align the Upper Mounting Bracket on the Upper Panel and the Lower Mounting Bracket on the Lower Panel Important For some materials pilot holes may need to be drilled first before screwing the Mounting Bracket onto the Panel Be sure the drill does not damage the face of the Panel ENSURE BRACKETS ARE ALIGNED Important T The mounting bracket must not be modified in any way It is designed to hold the door front in the correct position to allow venting Important The top door front must not extend beyond the bottom of the mounting bracket Drying problems and moisture damage may otherwise occur Important Break off the tab at the top of the Lower Mounting
7. Fisher amp Paykel part number 526608 J 06 2004 page 1 of 6 DOUBLE DishDrawer INTEGRATED PANEL PREPARATION FOR INTEGRATED DOUBLE MODELS DD603 NOTE FOR SINGLE DishDrawer MODELS REFER TO BACK OF THIS BOOK PLEASE NOTE Your model of DishDrawer may differ from the model shown in the diagrams Diagrams have been simplified to enable clearer instruction FOLLOW THESE INSTRUCTIONS BEFORE REFERRING TO PRODUCT INSTALLATION INSTRUCTION SHEET P N 526607 BEFORE YOU START 3 49 2 5mm MINIMUM CLEARANCE 346 5mm MINIMUM CLEARANCE The Door and Toe Kick Panels of the DishDrawer can be made to match your kitchen cabinetry This diagram with the addition of your own measurements will help you calculate the required panel sizes CABINETRY ALIGNMENT l The following calculations Height of Lower assume Panel The top of the Upper Panel is to be aligned with the top of the adjacent cabinetry The Bottom of adjacent final panel cabinetry alignment eae is achieved by adjusting the DishDrawer s feet WIDTH OF ALL PANELS Measure A the width between adjacent door drawer fronts and write it in the first box below then complete the equation For example A 2414 616mm 2x 342 2 5mm 246 611mm door clearance width of all panels 1o 2d amp __ j _ door clearance width of all panels 3 32 2 5mm MIN 23 7 46 595mm MIN HEIGHT OF UPPER PANEL For example
8. ND CAREFULLY STEP 1 BADGE AND HANDLE POSITION o 228 5mm 9 228 5mm BADGE AND HANDLE POSITIONS On both Panels select the Badge position to suit the cabinetry design within the available badge zones The Badge may be centered on the edge of the badge zone The handle position will also need to be taken into account Available Badge Zones Allow for Handle STEP 2 BADGE CUT OUT amp BRACKET REMOVAL BADGE CUT OUT 13 46 Veal 30mm 0 5mm 1 1g 25 4mm 0 25mm Cut the badge slot in each Panel by drilling two 1 25 4mm diameter holes and cutting out the remaining material between the holes A hole center to hole center template is provided on the Mounting Backet N WARNING Be sure the Product is not plugged in Bade Important ee Accuracy is essential when cutting the Badge slot to be sure of a neat fit to hold the Badge REMOVING THE BRACKET 1 To remove the Mounting Brackets withdraw the pins from the Drawer sides using a pair of needle nose pliers 2 Gently slide the Mounting Bracket off in a downwards and outwards motion Disconnect the Mounting Bracket and Badge grounding wires also unplug the Badge harness from the Badge Isolator box Remove the Badge from the Mounting Bracket NOTE The four 3 3 3mm holes on the perimeter of the F rectangular recess in the Mounting Bracket can also be used T Badge Zone to define the badge zone PANEL PR
9. ce Be sure you are adequately grounded when connecting or disconnecting the Badge by wearing a grounding strap or by grounding yourself to the DishDrawer PANEL PREPARATION INSTRUCTIONS DishDrawer STEP 7 FITTING THE PANELS TO THE PRODUCT Fit the assembled Panels by sliding in an inwards and upwards motion The rubber seal between the Drawer and Panels must be kept in place Secure the Panels by inserting the pins on either side of the Drawer Be sure that the rib on the pin Is vertical NOTE Do not fit the Toe Kick Panel or supplied Black the cavity Important moisture damage may occur INTEGRATED PANEL PREPARATION IS COMPLETE The Product is now ready to install Refer to Product Installation Instruction Sheet P N 526607 CUSTOMER CARE Fisher amp Paykel If you have any questions concerning the installation of appliances this DishDrawer please contact your Fisher amp Paykel Authorized Service Agent USA Fisher amp Paykel Appliances 27 Hubble Irvine CA 92618 Toll Free 1 888 9 FNP USA 7 888 9 367 872 www usa fisherpayKel com Prefinished Toe Kick to the DishDrawer until the Product is in The gap between doors must be 6 8mm or drying problems and Fisher amp Paykel part number 526608 J 06 2004 page 1 of 6 SINGLE DishDrawer INTEGRATED PANEL PREPARATION FOR INTEGRATED SINGLE MODELS DS603 NOTE FOR DOUBLE DishDrawer MODELS REFER TO BACK OF THIS BOOK
10. e 341 1870mm 2815 46 735mm 1 9 12mm 47142 123mm Toe Kick Panel is 2 67mm To move the Toe Kick deeper the Toe Kick Panel must have the profile l Mi T e Mew shown in the diagram below cut out of it The maximum Toe Kick depth 735mm 12mm with the cut out excluding the Toe Kick Panel is 5 127mm Height of adjacent Door extension DishDrawer MIN height of Toe cabinetry dimension clearance Kick Panel MIN 234 27 3 70 5mm 55mm 17 432mm ee ee R 12 7mm Toe Kick Panel PARTS SUPPLIED INTEGRATED PARTS KIT part no 526674 INTEGRATED PREPARATION BOOKLET Panel Panel Toe Kick Integrated Rectangular Badge 2 Preparation Mounting Mounting Satin Chrome supplied Booklet 1 Screws 12 Screws 5 p n 526975 Mounting Bracket 2 Upper and Lower Other Badges Available p n 526440 amp 526441 Rectangular Bright Chrome Kit p n 527276 Brass Kit p n 527277 a TOOLS NEEDED Eliptical Da Black Kit p n 526683 N Safety Glasses Tape Measure Pencil Needle Nose Pliers Drill amp Phillips Satin Chrome Kit p n 526684 Door Front Seal 2 Sy Bit or Phillips Screwdriver 1 25 4mm Boring Bit or 1 25 4mm Bright Chrome Kit p n 527156 p n 526466 Hole Saw Small Hand or Jig Saw Brass Kit p n 526685 Toe Kick Mounting Bracket 1 p n 526682 PANEL PREPARATION INSTRUCTIONS DishDrawer READ THESE INSTRUCTIONS COMPLETELY A
11. ential when cutting the Badge slot to ensure a neat fit Not shown to scale to hold the Badge REMOVING THE BRACKET 1 To remove the Mounting Bracket withdraw the pins from the Drawer sides using a pair of needle nose pliers 2 Gently slide the Mounting Bracket off in a downwards and outwards motion Disconnect the Mounting Bracket and Badge grounding wires also unplug the Badge harness from the Badge Isolator box Remove the Badge from the Mounting Bracket 1 NOTE The four 3 3 3mm holes on the perimeter of the rectangular recess in the Mounting Bracket can also be used to define the badge zone Badge Zone PANEL PREPARATION INSTRUCTIONS DishDrawer STEP 3 FITTING THE HANDLE AND BADGE FITTING THE HANDLE Fit the customer supplied handle Z WARNING When mounting the handle be sure fastenings do not protrude beyond the back surface of the Panel FITTING THE BADGE Fit the Badge to the Panel by feeding the wires through to the back and pressing the Badge into the cut out If needed adhere the Badge to the Panel with an adhesive Feed the Badge wires through the slot in the Mounting Bracket As the Mounting Bracket is placed on the rear of the Panel the excess wire must be pulled through STEP 4 SECURING THE MOUNTING BRACKETS MOUNTING BRACKET The Mounting Bracket is directly screwed to the back of the Integrated Panel On a soft surface centralize and align the Mounting Bracket on the Pane
12. g the Badge by wearing an grounding strap or by grounding yourself to the DishDrawer re a WY l f Connect the Badge plug to the top of the Badge Isolator Box PANEL PREPARATION INSTRUCTIONS DishDrawer STEP 7 FITTING THE PANELS TO THE PRODUCT Fit the assembled Panel by sliding in an inwards and upwards motion The rubber seal between the Drawer and Panel must be kept in place Secure the Panel by inserting the pins on either side of the Drawer Be sure that the rib on the pin Is vertical Important The airflow gap between the bottom of the door panel and adjacent cabinetry must be 3 3 9mm or drying problems and moisture damage may occur INTEGRATED PANEL PREPARATION IS COMPLETE The Product is now ready to install Refer to Product Installation Instruction Sheet P N 526607 CUSTOMER CARE Fisher amp Paykel If you have any questions concerning the installation of appliances this DishDrawer please contact your Fisher amp Paykel Customer Care Authorized Service Agent USA Fisher amp Paykel Appliances 27 Hubble Irvine CA 92618 Toll Free 7 888 9 FNP USA 7 888 9 367 872 www usa fisherpaykel com
13. ket 1 Preparation Mounting p n 526440 Booklet 1 Screws 6 Other Colours Available Rectangular Bright Chrome Kit p n 527276 TOOLS NEEDED Brass Kit p n 527277 OOLS Black Ki Safety Glasses Tape Measure Pencil Needle Nose Pliers Drill amp Phillips Black Kit p n 526683 Bit or Phillips Screwdriver 1 25 4mm Boring Bit or 1 25 4mm Satin Chrome Kit p n 526684 Hole Saw Smal Hand or lias Bright Chrome Kit p n 527156 pee ole Saw Small Hand or Jig Saw Brass Kit p n 526685 PANEL PREPARATION INSTRUCTIONS DishDrawer READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY STEP 1 BADGE AND HANDLE POSITION BADGE AND HANDLE POSITIONS 99 99 ieee omni Zee omy On both Panel select the Badge position to suit the cabinetry design within the available badge zone lf required the Badge may be centered on the edge of the badge zone The handle position will also need to be taken into account Allow for Handle Available Badge Zone 85 46 211mm 5 127mm STEP 2 BADGE CUT OUT amp BRACKET REMOVAL BADGE CUT OUT 13 46 Veg Savin 0 5mm D1 Vey Cut the badge slot in the Panel by drilling two 1 25 4mm diameter holes 25 4mm 0 25mm and cutting out the remaining material between the holes A hole center to hole center template is provided on the Mounting Backet Z WARNING Be sure the Product is not plugged in lt Badge ae ie Important Accuracy is ess
14. l Important For some materials pilot holes may need to be drilled first before screwing the Mounting Bracket onto the Panel Be sure the drill does not damage the face of the Panel gt Important JE ENSURE BRACKET The mounting bracket must not be modified in any way Itis designed z 5 IS ALIGNED OVER a zi PANEL EDGE to hold the door front in the correct position to allow venting Important The door front must not extend beyond the bottom of the mounting bracket Drying problems and moisture damage may otherwise occur Using six of the 16mm screws supplied secure the Mounting Bracket to each Panel at the six points shown in the diagram NOTE If the the six outermost slots are not able to be used to securely fix the Mounting Brackets to the Panel choose any six well spaced slots about the Panel PANEL PREPARATION INSTRUCTIONS DishDrawer STEP 5 GROUNDING THE MOUNTING BRACKETS Z WARNING Be sure the Product is not plugged in Plug the green Badge grounding wire onto a Mounting Bracket tab Plug the grounding wire from the Product onto the other Mounting Bracket tab Z N WARNING The mounting bracket MUST be grounded STEP 6 CONNECTING THE BADGE WIRES Z WARNING Be sure the Product is not plugged in Important The Badge Isolator Board is an electrostatic sensitive device Be sure you are adequately grounded when connecting or disconnectin