1. A710B AB OOS ge i a A Listed to UL 217 Standard 9V Battery Powered Description First Alert Model SA710 is a battery operated single station photoelectric smoke alarm specifically designed for residential and institutional applications including sleeping rooms of hospitals hotels motels dormitories and other multifamily dwellings as defined in standard NFPA 101 Model SA710 has been fully tested and complies with UL217 CSFM NFPA 72 and NFPA 101 and other agencies that model their codes after the above agencies It meets building codes where battery operated photoelectric with Silence smoke alarms are required and with model building codes published by the ICC First Alert Model SA710 is a state of the art smoke alarm designed to provide early warning of a fire It features a photoelectric smoke sensing chamber an 850B horn a supervised 9V battery power supply cat no SA710AB features an extended life alkaline battery a single button test silence switch a silence feature to silence unwanted nuisance alarms a red LED light that indicates DC power or alarm Optipath 360 technology provides 360 degrees of direct access to the smoke sensing chamber It also features tamper resistant locking pins that lock the alarm to the mounting bracket and or the battery drawer to prevent removal of battery Battery installation and removal can occur while the unit is mounted to the ceiling or wall via the slide out batter
2. SMOKE ALARM i Cube 53 9 ft3 Weight 707 Ibs TOP OF ALARM 1 Test Silence button BATTERY DRAWER LOCK 2 Slide open battery drawer o Remove Pin from Close Door Insert Pin in Holes 3 Red Alarm Light Mounting Bracket through alarm and Battery Drawer BOTTOM OF ALARM 1 Mounting bracket 2 Mounting Slots 3 Battery Drawer Install 9V battery here 4 Turn this way to remove from bracket 2009 BRK Brands Inc a J arden Corporation Company NYSE AH 3901 Liberty Street Road Aurora IL 60504 8122 All rights reserved First Alert is a registered trademark of the First Alert Trust brkelectronics com Aen registered trademark of BRK Brands Inc 5 Turn this way to attach to bracket
3. solid state SHIPPING SPECS piezo horn rated at 85dB at 10 ft 5 A visual red LED power on indicator to confirm unit is receiving power or Individual Carton Dimensions 5 125 L x 2 380 W x 5 125 H Sin alarm Weight 0 53lbs 6 A full function test button should check all alarm functions by simulating a smoke ee condition causing the unit to alarm Cube 0 036 ft3 7 Silence feature Temporarily silence unwanted nuisance alarms UPC SATLOB 0 29054 65660 5 9 Optipath 360 Technology provides 360 degrees of direct access to the SA7LOAB 0 29054 00285 3 smoke ee chambers a Master Carton Dimensions 10 630 L x 7 880 W x 10 880 H 10 Two Locking features tamper resistant locking pins that lock battery drawer and or alarm to mounting bracket Master Pack 12 11 The unit shall be capable of operating between 40F 4 C and Weight 7 31bs 100 F 38T and relative humidity between 10 and 90 12 The unit shall contain mounting hardware and shall be listed for wall alle penne or ceiling mounting UPC SA710B 100 29054 65660 2 13 The unit shall at a minimum meet the requirements of UL217 CSFM SA710AB 100 29054 00285 0 NFPA 72 NFPA 101 ICC Pallet Information INSTALLATION OF ALARM Cases per Layer 22 Installation of this smoke alarm must conform to NFPA 72 Always check your local Number of Layers 4 building codes Follow all instructions for placement as outlined in the user s manual Cases per Pallet 88 Units per Pallet 1 056 THE PARTS OF THIS
4. y drawer When battery power drops to a pre set warning level the horn will chirp approximately once per minute to indicate a fresh battery is needed Designed for wall or ceiling mounting Includes mounting anchors and screws E iL f a SA710B AB TECHNICAL SPECS DDO D Alarm Dimensions 5 0 dia x 2 1 H MOUNTING Weight 8 0 oz TOP VIEW SIDE VIEW BRACKET Operating Voltage 9V Battery Powered SA710AB Alkaline Battery BN d Temperature Range 40F 4C to 100F 38C Humidity Range 10 to 90 relative humidity RH Audio Alarm 85dB at 10 feet Test Silence Electronically simulates smoke condition causing the unit to alarm Manual Press and hold test silence button a A Alarm Reset Automatic when smoke clears 21 Smoke Sensor Photoelectric Indicator Lights Sounds ARCHITECTURAL AND ENGINEERING SPEC ake net The smoke alarm shall be a First Alert Model SA710B carbon zinc battery or SA710AB Aa eA E alkaline battery and shall provide at a minimum the following features and functions Listing UL to UL217 Standard 1 A Photoelectric smoke sensing chamber 2 The unit shall be capable of self restoring 3 Fully screened sensing chamber to resist entry of small insects thereby reducing the probability of unwanted alarms 4 Powered by a supervised 9V alkaline cat no SA710AB battery and a
Download Pdf Manuals
Related Search
Related Contents
Owners Manual Samsung MW89MST Manual de Usuario Akai AM-67 User's Manual Honeywell ST 3000 Satellite Radio User Manual Shure SRH550DJ User's Manual TSR Router Menu-Driven User Interface User Manual 2.97 NMS 410/450 Copyright © All rights reserved.
Failed to retrieve file