1. escape ladders or other reliable means of escape from an upper floor in case stairs are blocked BEFORE YOU INSTALL THIS SMOKE ALARM IMPORTANT Read Recommended Locations for Smoke Alarms and Locations to Avoid For Smoke Alarms before beginning This unit monitors the air and when smoke reaches its sensing chamber it alarms It can give you more time to escape before fire spreads This unit can ONLY give an early warning of developing fires if it is installed maintained and located where smoke can reach it and where all residents can hear it as described in this manual This unit will not sense gas heat or flame It cannot prevent or extinguish fires Understand The Different Type of Smoke Alarms Battery powered or electrical Different Smoke Alarms provide different types of protection See About Smoke Alarms for details Know Where To Install Your Smoke Alarms Fire Safety Professionals recommend at least one Smoke Alarm on every level of your home in every bedroom and in every bedroom hallway or separate sleeping area See Recommended Locations For Smoke Alarms and Locations To Avoid For Smoke Alarms for details Know What Smoke Alarms Can and Can t Do A Smoke Alarm can help alert you to fire giving you precious time to escape It can only sound an alarm once smoke reaches the sensor See Limitations of Smoke Alarms for details Check Your Local Building Codes This Smoke Alarm is d
2. fit into a notch on the bracket UNDERSTANDING THE LIGHT AND HORN PATTERNS When your smoke alarm is in this mode This is what you should hear This is what you should see Normal Operating Condition Nothing Horn is silent Red Light flashes every minute Test Horn sounds loudly Horn pattern repeats twice Red Light flashes rapidly 3 beeps pause 3 beeps pause Alarm Horn sounds loudly Repeating horn pattern 3 beeps pause 3 beeps pause Repeats for as long as unit is in alarm Nothing Horn is silent for up to 15 minutes Red Light flashes rapidly Horn chirps once a minute Red Light flashes every minute Low Battery Warning Silenced Nothing Horn is silent for up to eight hours A series of two rapid flashes once a minute A series of three rapid chirps once every minute Red Light flashes every minute WEEKLY TESTING It is important to test this unit every week to make sure it is working properly Using the test button is the recommended way to test this Smoke Alarm During testing you will hear a loud repeating horn pattern 3 beeps pause 3 beeps pause You can test this Smoke Alarm two ways Manually Press the Test Silence button on the alarm cover until alarm sounds for 3 5 seconds Using Your Remote Control Standing no fur ther than 20 feet away from the Smoke Alarm aim your IR remote at the Smoke Alarm and Red Light flashes rapidly Alarm Silenced Low Battery Warning AWARN
3. flathead screwdriver under the head of the locking pin and gently pry it out of the battery compartment lock If you plan to re lock the battery com partment save the locking pin To re lock the battery compartment close the battery door and reinsert locking pin in lock If the unit does not alarm during testing DO NOT lock the battery compartment Install a new battery and test again If the Smoke Alarm still does not alarm replace it immediately Reattach the Smoke Alarm to the mounting bracket IMPORTANT When replacing the battery always test the Smoke Alarm before re 3 Using needle nose pliers or a utility knife detach one locking pin from the mounting bracket Push the locking pin through the hole near the battery door latch on the back of the Smoke Alarm TO LOCK THE MOUNTING BRACKET ii Using needle nose pliers detach one locking pin from the mounting bracket Insert the locking pin through the hole on the back of the Smoke Alarm as shown in the diagram locking the battery compartment TO UN LOCK THE MOUNTING BRACKET 1 Insert a flathead screwdriver into the rectangular cut out on the mounting bracket nearest to the locking pin Pry the Smoke Alarm away from the bracket by pushing up on the screwdriver and turning the Smoke Alarm counterclockwise When you attach the Smoke left at the same time Alarm to the mounting brack et the locking pin s head will
4. is a registered trademark of the First Alert Trust Printed in Mexico M08 0071 002 D 07 04
5. on the Smoke Alarm Match to and to Push the battery in until it snaps in securely and cannot be shaken loose If the battery is not snapped in completely the unit cannot 3 Vertical 6 mounting slot 2 of 2 Swing open battery L f drawer Turn this way to remove from bracket Turn this way to attach 5 to bracket receive battery power NOTE After you install the battery the power indicator light will flash and the horn will chirp If the unit alarms the light will blink rapidly and the horn will repeatedly sound 3 beeps pause 3 beeps TOOLS YOU WILL NEED This unit is designed to be mounted onthe ceiling or On Mae wall if necessary Attach the Smoke Alarm to the bracket Line up the guides on the e Pencil alarm s base with the guides on the mounting bracket When guides e Drill with 3 16 5 mm drill bit are lined up turn the base clockwise right until it snaps into place e Standard flathead screwdriver NOTE Once the Smoke Alarm is snapped onto the bracket you can rotate the cover to adjust the alignment e Hammer e Pliers or utility knife to activate optional Tes ene Smoke Alarmi See SWeekIy Testing tamper resistant locking features OPTIONAL LOCKING FEATURES The locking features are designed to discourage unauthorized removal of the battery or Alarm It is not necessary to activate the locks in single family households where unauthorized battery or Ala
6. units can not work if the AC power is cut off for any reason open fuse or circuit breaker failure along a power line or at a power station electrical fire that burns the electrical wires etc If you are concerned about the limitations of battery or AC power install both types of units Smoke Alarms cannot detect fires if the smoke does not reach them Smoke from fires in chimneys or walls on roofs or on the other side of closed doors may not reach the sensing chamber and set off the alarm That is why one unit should be installed inside each bedroom or sleeping area especially if bedroom or sleeping area doors are closed at night and in the hallway between them Smoke Alarms may not detect fire on another floor or area of the home For example a stand alone unit on the second floor may not detect smoke from a basement fire until the fire spreads This may not give you enough time to escape safely That is why recommended minimum protection is at least one unit in every sleeping area and every bedroom on every level of your home Even with a unit on every floor stand alone units may not provide as much protection as interconnected units especially if the fire starts in a remote area Some safety experts recommend installing interconnected AC powered units with battery back up see About Smoke Alarms or profes sional fire detection systems so if one unit senses smoke all units alarm Interconnected units may provide earlier
7. ING e NEVER use an open flame of any kind to test this unit You might accidentally damage or set fire to the unit or to your home The built in test switch accurately tests the unit s operation as required by Underwriters Laboratories Inc UL If you choose to use an aerosol smoke product to test the Smoke Alarm be certain to use one that has been Listed to Underwriters Laboratories Inc Safety Standards and use it only as directed Use of non UL Listed prod ucts or improper use of UL Listed products may affect the Smoke Alarm s sensitivity If the Alarm ever fails to test properly replace it immediately Products under warranty may be returned to the manufacturer for replacement See Limited Warranty at the end of this manual Ufo cad DO NOT stand close to the alarm when the horn is sounding Exposure at close range may be harmful to your hearing When testing step away when horn starts sounding press the CHANNEL or VOLUME button for at y If the alarm does not respond to your remote control there may be an obstruction between least 3 5 seconds Ma F you and the alarm you may be standing too far away or your remote control may not be 2 A compatible REGULAR MAINTENANCE This unit has been designed to be as maintenance free as possible but there are a few simple things you must do to keep it working properly AWARNING Use only the replacement batteries listed below The unit may not operate proper
8. Inc BRK the maker of First Alert brand products warrants that for a period of ten years from the date of purchase this product will be free from defects in material and workmanship BRK at its option will repair or replace this product or any component of the product found to be defective during the war ranty period Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value This is your exclusive warranty This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable Keep the original sales receipt Proof of purchase is required to obtain warranty performance BRK dealers service centers or retail stores selling BRK products do not have the right to alter modify or any way change the terms and conditions of this warranty This warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instructions disassembly repair or alteration by anyone other than BRK or an authorized service center Further the war ranty does not cover Acts of God such as fire flood hurricanes and tornadoes or any batteries that are included with this unit BRK shall not be liable for any incidental or consequential damages caused by the b
9. OOM 4 ie HOMES Exe BEDROOM HALL BEDROOM KEY SMOKE ALARMS FOR MINIMUM PROTECTION A ADDITIONAL SMOKE ALARMS FOR BETTER KITCHEN COVERAGE LIVING ROOM E KITCHEN A p rmen BASEMENT ZX SMOKE ALARMS WITH SILENCE FEATURE RECOMMENDED FOR KITCHENS FINISHED BASEMENT MULTI STORY i MULTI STORY RESIDENCE INTERCONNECTED KITCHEN DINING ROOM AC OR AC DC BEDROOM KITCHEN DINING ROOM SMOKE ALARMS O LIVING ROOM LIVING ROOM 1 STORY RESIDENCE 1 STORY RESIDENCE INSTALLING SMOKE ALARMS IN MOBILE HOMES amp RVS For minimum security install one Smoke Alarm as close to each sleeping area as possible For more security put one unit in each room Many older mobile homes especially those built before 1978 have little or no insulation If your mobile home is not well insulated or if you are unsure of the amount of insu lation it is important to install units on inside walls only Smoke Alarms should be installed where temperatures normally remain between 40 F 4 C and 100 F 38 C WARNING Test units used in RVs after the vehicle has been in storage before every trip and once a week while in use Failure to test units used in RVs as described may remove your protection IMPORTANT This equipment should be installed in accordance with NFPA National Fire Protection Association 72 and 101 National Fire Protection Association One Batterymarch Park Quincy MA 02269 9101 Additional local bu
10. USER S MANUAL SMOKE AND FIRE ALARM WITH REMOTE CONTROL FEATURES IMPORTANT PLEASE READ CAREFULLY AND SAVE This user s manual contains important information about your Smoke Alarm s operation If you are installing this Smoke Alarm for use by others you must leave this manual or a copy of it with the end user M08 0071 002 D 07 04 Printed in Mexico Model SA302 TABLE OF CONTENTS Features and Benefits 00 0c cece eee eee eee 1 Fire Safety TIPS sicisvissiisiceeseta ge setdcee anaa E ate aE vena id 1 Before You Install This Smoke Alarm 000 eee eee eee eens 1 How To Install This Smoke Alarm 0000 eee ee eee eee eee 2 Optional Locking Features 000cc eee e eee n eee 2 3 Understanding the Light and Horn Patterns 00 cee eaeee 3 Weekly Testing aia jicissaijayieg eis sacha sass a alae sa yard sara na etapa fa fanaa AE EN 3 Regular Maintenance 000 cece eee eee eee 4 If This Smoke Alarm Sounds 00000 e eee eee eee eee 4 What To Do In Case Of Fire 0 00 cece eee 4 Using The Silence Features 000c cee ene nee e eens 4 If You Suspect A Problem 0c eee eee eee eee eee 4 Recommended Locations For Smoke Alarms 000eeeeeee 5 Locations To Avoid For Smoke Alarms 00 eee eee eee eeee 5 About Smoke Alarms 0 0 00 5 Special Compliance Considerations 000 eee eee eee 6 Limitations Of Smoke Alarms 000 cece eee eee eee 6 Limited Warrant
11. all rooms and areas of the household as follows A Smoke Alarm installed in each separate sleeping area in the vicinity but outside bedrooms and Heat or Smoke Alarms in the living rooms dining rooms bedrooms kitchens hallways finished attics furnace rooms closets utility and storage rooms basements and attached garages LOCATIONS TO AVOID FOR SMOKE ALARMS For best performance it is recommended you AVOID installing Smoke Alarms in these areas Do not install this Smoke Alarm in a location where it could be easily triggered when using your remote to operate your TV VCR or other remote controlled appliances e Where combustion particles are produced Combustion particles form when something burns Areas to avoid include poorly ventilated kitchens garages and furnace rooms Keep units at least 20 feet 6 meters from the sources of combustion particles stove furnace water heater space heater if possible In areas where a 20 foot 6 meter distance is not possible in modular mobile or smaller homes for example it is recommended the Smoke Alarm be placed as far from these fuel burning sources as possible The placement recommendations are intended to keep these Alarms at a reasonable distance from a fuel burning source and thus reduce unwanted alarms Unwanted alarms can occur if a Smoke Alarm is placed directly next to a fuel burning source Ventilate these areas as much as possible e In air streams near ki
12. allowed by building codes the top edge of Smoke Alarms should be placed between 4 and 12 inches 102 and 305 mm from the wall ceiling line below typical dead air spaces On a peaked gabled or cathedral ceiling install the first Smoke Alarm within 3 feet 0 9 meters of the peak of the ceiling measured horizontally Additional Smoke Alarms may be required depending on the length angle etc of the ceiling s slope Refer to NFPA 72 for details on requirements for sloped or peaked ceilings ABOUT SMOKE ALARMS Battery DC operated Smoke Alarms Provide protection even when electricity fails provided the batteries are fresh and correctly installed Units are easy to install and do not require professional installation AC powered Smoke Alarms Can be interconnected so if one unit senses smoke all units alarm They do not operate if electricity fails AC with battery DC back up will operate if electricity fails provided the batteries are fresh and correctly installed AC and AC DC units must be installed by a qualified electrician Smoke Alarms for Solar or Wind Energy users and battery backup power systems AC powered Smoke Alarms should only be operated with true or pure sine wave inverters Operating this Smoke Alarm with most battery pow ered UPS uninterruptible power supply products or square wave or quasi sine wave inverters will damage the Alarm If you are not sure about your inverter or UPS type please consu
13. esigned to be used in a typical single family home It alone may not meet requirements for boarding houses apartment build ings hotels or motels See Special Compliance Considerations for details AWARNING e This unit will not alert hearing impaired residents It is recom mended that you install special units which use devices like flashing strobe lights to alert the hearing impaired Do not connect this unit to any other alarm or auxiliary device It is a single station unit that cannot be linked to other devices Connecting anything else to this unit may prevent it from work ing properly Unit will not operate without battery power The Smoke Alarm cannot work until you install the battery in the correct position Match to and to This Smoke Alarm has a battery drawer which resists closing unless a battery is installed This warns you the unit will not operate without a battery ACAUTION e Do not install this unit over an electrical junction box Air cur rents around junction boxes can prevent smoke from reaching the sensing chambers and prevent the unit from alarming Only AC powered units are intended for installation over junction boxes Do not stand too close to the unit when the alarm is sounding It is loud to wake you in an emergency Exposure to the horn at close range may harm your hearing Do not paint over the unit Paint may clog the openings to the sensing chambers and
14. ies hallways or porches Using this Smoke Alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances regulations LIMITED WARRANTY LIMITATIONS OF SMOKE ALARMS Smoke Alarms have played a key role in reducing deaths resulting from home fires worldwide However like any warning device Smoke Alarms can only work if they are properly located installed and maintained and if smoke reaches them They are not foolproof Smoke alarms may not waken all individuals Practice the escape plan at least twice a year making sure that everyone is involved from kids to grand parents Allow children to master fire escape planning and practice before holding a fire drill at night when they are sleeping If children or others do not readily waken to the sound of the Smoke Alarm or if there are infants or family members with mobility limitations make sure that someone is assigned to assist them in fire drill and in the event of an emergency It is recommended that you hold a fire drill while family members are sleeping in order to deter mine their response to the sound of the Smoke Alarm while sleeping and to determine whether they may need assistance in the event of an emergency Smoke Alarms cannot work without power Battery operated units cannot work if the batteries are missing disconnected or dead if the wrong type of batteries are used or if the batteries are not installed correctly AC
15. ilding and regulatory codes may apply in your area Always check compliance require ments before beginning any installation AGENCY PLACEMENT RECOMMENDATIONS NFPA 72 National Fire Code Smoke Alarms shall be installed in each separate sleeping room outside each sleeping area in the immediate vicinity of the bedrooms and on each addition al story of the family living unit including basements and excluding crawl spaces and unfinished attics In new construction Alarms shall be so arranged that operation of any one Alarm shall cause the operation of all Alarms within the dwelling Smoke Detection Are More Smoke Alarms Desirable The required num ber of Smoke Alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required Smoke Alarms For this reason it is recommended that the householder con sider the use of additional Smoke Alarms for those areas for increased protec tion The additional areas include the basement bedrooms dining room fur nace room utility room and hallways not protected by the required Smoke Alarms The installation of Smoke Alarms in kitchens attics finished or unfin ished or garages is not normally recommended as these locations occasion ally experience conditions that can result in improper operation California State Fire Marshal CSFM Early warning detection is best achieved by the installation of fire detection equipment in
16. ilence this Smoke Alarm from up to 20 feet away PEACE AND QUIET Silence The Low Battery Warning If the low battery warning starts chirp ing at 2 00 in the morning you can silence it for up to eight hours go back to sleep and change the battery when you wake up Just use the Remote Control Test Silence Feature or press and hold the Test Silence button for 3 5 seconds FEWER NUISANCE ALARMS Intelligent Sensing Technology The microprocessor in this Smoke Alarm evaluates smoke in a different way While it can t eliminate all non emer gency alarms it can potentially reduce their numbers FIRE SAFETY TIPS Follow safety rules and prevent hazardous situations 1 Use smoking materi als properly Never smoke in bed 2 Keep matches or lighters away from chil dren 3 Store flammable materials in proper containers 4 Keep electrical appliances in good condition and don t overload electrical circuits 5 Keep stoves barbecue grills fireplaces and chimneys grease and debris free 6 Never leave anything cooking on the stove unattended 7 Keep portable heaters and open flames like candles away from flammable materials 8 Don t let rubbish accumulate Keep alarms clean and test them weekly Replace alarms immediately if they are not working properly Smoke Alarms that do not work cannot alert you to a fire Keep at least one working fire extinguisher on every floor and an addi tional one in the kitchen Have fire
17. lace the battery as soon as possible this unit will not operate without battery power To deactivate this feature Press the Test Silence button or use your remote control again The unit will go into Test Mode and the low battery warning will resume LED flashes and unit sounds chirp once a minute If you cannot silence the low battery warning replace your battery immediately IF YOU SUSPECT A PROBLEM Smoke Alarms may not operate properly because of dead missing or weak batteries a build up of dirt dust or grease on the Smoke Alarm cover or installation in an improper location Clean the Smoke Alarm as described in Regular Maintenance and install a fresh battery then test the Smoke Alarm again If it fails to test properly when you use the test button or if the problem persists replace the Smoke Alarm immediately e If you hear a chirp once a minute replace the battery e If you experience frequent non emergency alarms like those caused by cooking smoke try relocating the Smoke Alarm e Ifthe alarm sounds when no smoke is visible try cleaning or relocating the Smoke Alarm The cover may be dirty e Ifthe alarm does not sound during testing try installing a new battery and make sure it is snapped in securely Do not try fixing the alarm yourself this will void your warranty If the Smoke Alarm is still not operating properly and it is still under warranty please see How to Obtain Warranty Se
18. lt with the manufacturer to verify Smoke Alarms for the hearing impaired Special purpose Smoke Alarms should be installed for the hearing impaired They include a visual alarm and an audible alarm horn and meet the requirements of the Americans With Disabilities Act Can be interconnected so if one unit senses smoke all units alarm SPECIAL COMPLIANCE CONSIDERATIONS AWARNING This Smoke Alarm alone is not a suitable substitute for complete fire detection systems in places housing many people like apartment buildings condo miniums hotels motels dormitories hospitals long term health care facilities nursing homes day care facilities or group homes of any kind even if they were once single family homes It is not a suitable substitute for complete fire detection systems in warehouses industrial facilities commercial buildings and special purpose non residential buildings which require special fire detec tion and alarm systems Depending on the building codes in your area this Smoke Alarm may be used to provide additional protection in these facilities The following information applies to all four building types below In new construction most building codes require the use of AC or AC DC powered Smoke Alarms only In existing construction AC AC DC or DC powered Smoke Alarms can be used as specified by local building codes Refer to NFPA 101 Life Safety Code or NFPA 72 National Fire Alarm Code local building codes
19. ly with other batteries Never use rechargeable batteries since they may not provide a constant charge e Test it at least once a week e Clean the Smoke Alarm at least once a month gently vacuum the outside of the Smoke Alarm using your household vacuum s soft brush attachment Test the Smoke Alarm Never use water cleaners or solvents since they may damage the unit e If the Smoke Alarm becomes contaminated by excessive dirt dust and or grime and cannot be cleaned to avoid unwanted alarms replace the unit immediately e Relocate the unit if it sounds frequent unwanted alarms See Locations to Avoid for Smoke Alarms for details e When the battery becomes weak the Smoke Alarm unit will chirp about once a minute the low battery warning This low battery warning should last for 30 days but you should replace the battery immediately to contin ue your protection Choosing a replacement battery Your Smoke Alarm requires one standard 9V battery The following batteries are acceptable as replacements Duracell MN1604 Ultra MX1604 Eveready Energizer 522 You may also use a Lithium battery like the Ultralife U9VL J for longer service life between battery changes These batteries are available at many local retail stores With Optional Lithium Battery This model was shipped with a Lithium battery with 10 year warranty When you replace the original battery you must replace it with a Lithium battery for continued l
20. n a hot door Keep doors and windows closed unless you must escape through them e Cover your nose and mouth with a cloth preferably damp Take short shallow breaths e Meet at your planned meeting place outside your home and do a head count to make sure everybody got out safely e Call the Fire Department as soon as possible from outside Give your address then your name e Never go back inside a burning building for any reason e Contact your Fire Department for ideas on making your home safer AWARNING Alarms have various limitations See Limitations of Smoke Alarms for details USING THE SILENCE FEATURES SILENCING AN ALARM AWARNING The silence feature does not disable the unit it temporarily silences the horn For your safety if smoke around the unit is dense enough to sug gest a potentially dangerous situation it will stay in alarm or may re alarm quickly If you do not know the source of the smoke do not assume it is an unwanted alarm Not responding to an alarm can result in property loss injury or death The silence feature can temporarily quiet an unwanted alarm for several min utes You can silence this Smoke Alarm two ways 1 Manually Press the Test Silence button on the alarm cover for at least 3 5 seconds 2 Using Your Remote Control Standing no further than 20 feet away from the Smoke Alarm aim your IR remote at the Smoke Alarm and press the CHANNEL or VOLUME button for at least 3 5 seco
21. nds NOTE During an alarm you can only silence the alarm ONCE using the remote Silence feature The Test Silence button on the Smoke Alarm will continue to silence the alarm as needed The remote Silence feature will be automatically restored when the Smoke Alarm resets If the alarm does not respond to your remote control there may be an obstruction between you and the alarm you may be standing too far away or your remote control may not be compatible While the Smoke Alarm is in silence mode the LED will continue to flash the alarm pattern three times pause three times pause for up to 15 minutes It will stop flashing when the Smoke Alarm returns to normal operation If smoke levels rise the Smoke Alarm will return to alarm condition SILENCING THE LOW BATTERY WARNING This silence feature can temporarily quiet the low battery warning chirp for up to 8 hours without having to remove the battery You can silence the low battery warning chirp two ways 1 Manually Press the Test Silence button on the alarm cover 2 Using Your Remote Control Standing no further than 20 feet away from the Smoke Alarm aim your IR remote at the Smoke Alarm and press the CHANNEL or VOLUME button for at least 3 5 seconds Once the low battery warning chirp silence feature is activated the unit con tinues to flash the red light twice once a minute for 8 hours After 8 hours the low battery chirp will resume Rep
22. ong life power between battery changes IMPORTANT Actual battery service life depends on the Smoke Alarm and the environment in which it is installed All the batteries specified above are acceptable replacement batteries for this unit Regardless of the manufacturer s suggest ed battery life you MUST replace the battery immediately once the unit starts chirping the low battery warning IF THIS SMOKE ALARM SOUNDS RESPONDING TO AN ALARM During an alarm you will hear a loud repeating horn pattern 3 beeps pause 3 beeps pause AWARNING e Ifthe unit alarms and you are not testing the unit it is warning you of a potentially dangerous situation that requires your immediate attention NEVER ignore any alarm Ignoring the alarm may result in injury or death e Never remove the batteries from a battery operated Smoke Alarm to stop an unwanted alarm caused by cooking smoke etc Removing batteries disables the alarm so it cannot sense smoke and removes your protection Instead open a window or fan the smoke away from the unit The alarm will reset automatically e Ifthe unit alarms get everyone out of the house immediately WHAT TO DO IN CASE OF FIRE e Don t panic stay calm Follow your family escape plan e Get out of the house as quickly as possible Don t stop to get dressed or collect anything e Feel doors with the back of your hand before opening them If a door is cool open it slowly Don t ope
23. or consult your Fire Department for detailed fire protec tion requirements in buildings not defined as households 1 Single Family Residence Single family home townhouse It is recommended Smoke Alarms be installed on every level of the home in every bedroom and in each bedroom hallway 2 Multi Family or Mixed Occupant Residence Apartment building condominium This Smoke Alarm is suitable for use in individual apartments or condos provided a primary fire detection system already exists to meet fire detection requirements in common areas like lob bies hallways or porches Using this Smoke Alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordi nances regulations 3 Institutions Hospitals day care facilities long term health care facilities This Smoke Alarm is suitable for use in individual patient sleeping resident rooms provid ed a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies hallways or porches Using this Smoke Alarm in common areas may not provide sufficient warning to all resi dents or meet local fire protection ordinances regulations 4 Hotels and Motels Also boarding houses and dormitories This Smoke Alarm is suitable for use inside individual sleeping resident rooms provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobb
24. prevent the unit from operating properly HOW TO INSTALL THIS SMOKE ALARM THE PARTS OF THIS SMOKE ALARM Test Silence button Swing open battery drawer a Red Light Yar KS Mounting bracket STA Horizontal mounting slot 1 of 2 FOLLOW THESE SIMPLE STEPS IMPORTANT Do not install this Smoke Alarm in a location where it could be easily triggered when using your remote to operate your TV VCR or other remote controlled appliances If you want to lock the battery drawer or lock the Smoke Alarm to the mounting bracket please read the Optional Locking Features section before you begin installation iP Hold base firmly and twist the mounting bracket clockwise to sepa rate it from the base Hold the mounting bracket against the ceiling or wall so the vertical mounting slot is aligned in the 12 o clock position and trace around the inside of the mounting slots vertical and horizontal mounting Put the unit where it won t get covered with dust when you drill the mounting holes Using a 3 16 6 mm drill bit drill a hole through the center of the oval outlines you traced Insert the plastic screw anchors in the plastic bag with screws into the holes Tap the screw anchors gently with a hammer if necessary until they are flush with the ceiling or wall Attach the mounting bracket to the ceiling or wall Install the battery included so the terminals on the battery match the terminals
25. reach of any express or implied warranty Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty Some states provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province How to Obtain Warranty Service Service If service is required do not return the product to your retailer In order to obtain warranty service contact the Consumer Affairs Division at 1 800 323 9005 7 30 AM 5 00 PM Central Standard Time Monday through Friday To assist us in serving you please have the model number and date of purchase available when calling 303 Nelson Avenue Neosho MO 64850 8806 Battery BRK Brands Inc make no warranty express or implied written or oral including that of merchantability or fitness for any particular purpose with respect to battery Model SA302 with Lithium Battery BRK Brands Inc warrants the enclosed battery to be free from defects in materials and workmanship under normal use and service for a period of ten years from the date of purchase Warranty does not cover length of actual service life First Alert
26. rm removal is not a concern These Smoke Alarms have two separate locking features one to lock the battery compartment and the other to lock the Smoke Alarm to the mounting bracket You can choose to use either feature independently or use them both Tools you will need Needle nose pliers or utility knife Standard Flathead screwdriver Both locking features use locking pins which are molded into the mounting bracket Depending on which locking features you use remove one or both pins from the mounting bracket using needle nose pliers or a utility knife L IMPORTANT To permanently remove either lock insert a flathead screwdriver between the locking pin and the lock and pry the pin out of the lock TO LOCK THE BATTERY COMPARTMENT Do not lock the battery compartment until you activate the battery and test the Smoke Alarm a Install the battery so the termi nals on the battery match the terminals on the Smoke Alarm Match to and to Push the battery in until it snaps in securely and cannot be shak en loose If the battery is not snapped in completely the unit cannot receive battery power Push and hold test button until the alarm sounds 3 beeps pause 3 beeps pause IMPORTANT 7 UN LOCK THE BATTERY COMPARTMENT Remove the Smoke Alarm from the mounting bracket If the unit is locked to the brack et see the section To Un Lock the Mounting Bracket Insert a
27. rvice in the Limited Warranty RECOMMENDED LOCATIONS FOR SMOKE ALARMS Installing Smoke Alarms in Single Family Residences The National Fire Protection Association NFPA recommends one Smoke Alarm on every floor in every sleeping area and in every bedroom In new construction the Smoke Alarms must be AC powered and interconnected See Agency Placement Recommendations for details For additional coverage it is recommended that you install a Smoke Alarm in all rooms halls storage areas finished attics and basements where temperatures normally remain between 40 F 4 C and 100 F 38 C Make sure no door or other obstruction could keep smoke from reaching the Smoke Alarms More specifically install Smoke Alarms e Onevery level of your home including finished attics and basements e Inside every bedroom especially if people sleep with doors closed e In the hall near every sleeping area If your home has multiple sleeping areas install a unit in each e If ahall is over 40 feet 12 meters long install an alarm at each end e At the top of the first to second floor stairway and at bottom of basement stairway IMPORTANT Specific requirements for Smoke Alarm installation vary from state to state and from region to region Check with your local Fire Department for current requirements in your area It is recommended AC or AC DC units be interconnected for added protection NEW CONSTRUCTION a BEDROOM BEDR
28. tchens Air currents can draw cooking smoke into the sensing chamber of a Smoke Alarm near the kitchen e In very damp humid or steamy areas or directly near bathrooms with showers Keep units at least 10 feet 8 meters away from showers saunas dishwashers etc e Where the temperatures are regularly below 40 F 4 C or above 100 F 38 C including unheated buildings outdoor rooms porches or unfin ished attics or basements e In very dusty dirty or greasy areas Do not install a Smoke Alarm directly over the stove or range Keep laundry room Smoke Alarms free of dust or lint e Near fresh air vents ceiling fans or in very drafty areas Drafts can blow smoke away from the unit preventing it from reaching the sensing chamber e In insect infested areas Insects can clog openings to the sensing cham ber and cause unwanted alarms e Less than 12 inches 305mm away from fluorescent lights Electrical noise can interfere with the sensor e In dead air spaces Dead air spaces may prevent smoke from reach ing the Smoke Alarm Avoiding Dead Air Spaces Dead air spaces may prevent smoke from reaching the Smoke Alarm To avoid dead air spaces follow the installation recommendations below On ceilings install Smoke Alarms as close to the center of the ceiling as possible If this is not possible install the Smoke Alarm at least 4 inches 102 mm from the wall or corner For wall mounting if
29. warning than stand alone units since all units alarm when one detects smoke Smoke Alarms may not be heard Though the alarm horn in this unit meets or exceeds current standards it may not be heard if 1 the unit is located outside a closed or partially closed door 2 residents recently consumed alcohol or drugs 3 the alarm is drowned out by noise from stereo TV traffic air conditioner or other appliances 4 residents are hearing impaired or sound sleepers Special purpose units like those with visual and audible alarms should be installed for hearing impaired residents Smoke Alarms may not have time to alarm before the fire itself causes damage injury or death since smoke from some fires may not reach the unit immediately Examples of this include persons smoking in bed chil dren playing with matches or fires caused by violent explosions resulting from escaping gas Smoke Alarms are not foolproof Like any electronic device Smoke Alarms are made of components that can wear out or fail at any time You must test the unit weekly to ensure your continued protection Smoke Alarms cannot prevent or extinguish fires They are not a substitute for property or life insurance Smoke Alarms have a limited life The unit should be replaced immediately if it is not operating properly You should always replace a Smoke Alarm after 10 years from date of purchase Write the purchase date on the space provided on back of unit BRK Brands
30. y 0 0c eee 6 All Rights Reserved 2004 BRK Brands Inc BRK Brands Inc 3901 Liberty Street Road Aurora IL 60504 8122 Consumer Affairs 800 323 9005 e www firstalert com All First Alert Smoke Alarms conform to regulatory requirements including UL217 and are designed to detect particles of combustion Smoke particles of varying number and size are produced in all fires technology at detecting small particles which tend to be produced in greater amounts by flaming fires which consume combustible materials rapidly and spread quickly Sources of these fires may include paper burning in a wastebasket or a grease fire in the kitchen i lonization technology is generally more sensitive than photoelectric Photoelectric technology is generally more sensitive than ionization P technology at detecting large particles which tend to be produced in greater amounts by smoldering fires which may smolder for hours before bursting into flame Sources of these fires may include cigarettes burning in couches or bedding For maximum protection use both types of Smoke Alarms on each level and in every bedroom of your home FEATURES AND BENEFITS MAXIMUM PROTECTION Features lonization and Photoelectric Sensors You get the protection of both types of sensors in one easy to install Smoke Alarm ULTIMATE CONVENIENCE Remote Control Test Silence Feature Use the VOLUME or CHANNEL buttons on most remote controls to test or s