Faber room-sealed built-in gas-fireplace FEELING User's Manual

image

Contents

1. UK IRL 5 INSTALLATION OF THE FLUE 5 1 Connections with use of concentric duct material Build the system starting from the appliance on Make a hole of 153 mm for the wall or roof mounted terminal Make sure you place the pipes in the right direction the narrow end towards the appliance Make sure the pipes are fixed sufficiently a wall clamp every 2m so the weight of the pipes is not resting onto the appliance The outside of the pipe can become hot 140 degrees Stay 50 mm away from wall surface or sealing Make sure to provide sufficiently heat resistant isolation when going through the wall or roof Because of expansion or cooling down the concentric pipes can turn loose It is recommended to fix the spring clip with a self tapping screw at inaccessible places To get the exact measure flue length you can use cut down concentric pipe wall mounted terminal or roof mounted terminal To obtain a smoke sealed connection the inner pipe must be 20 mm longer then the outside pipe The horizontal pipes need to rise away from the appliance at a rate of 3 degrees per metre 27 UK IRL 5 2 Connection onto an existing chimney You can connect the appliance onto an existing chimney The existing chimney then functions as air supply where a flexible stainless steel liner to BS715 of 100 mm performs the flue function Any existing chimney used as an air supply must only service this appliance
2. Requirements 300 mm of free space above the appliance The chimney only supply s air to this appliance The existing chimney needs to be clean and very well swept The existing chimney needs to be airtight The existing chimney needs to have an opening of min 150 x 150 mm Parts needed for this kind of installation Chimney connection set part number A9225000 Fig 20 part D Short roof terminal part number A9266100 Fig 19 part B Chimney closure plate part number A 9240000 Fig 19 part A Two stainless steel tubes one 100 mm length 500 mm and one 150 mm length 500 mm part number A 9273900 Fig 19 part E and F 1 Place the aluminium closure plate A onto the chimney Permanently attach and make airtight 2 Pull the liner C through the chimney 3 Connect the liner onto the roof terminal and fix this with the clamp provided with the chimney connection set 4 Place the roof terminal onto the closure plate 28 5 10 11 UK IRL 5 2 Connection onto an existing chimney continuing Fixing the chimney sealing plate D and place the 150 mm grommet into the hole of the sealing plate Fix the sealing plate air tight into the builders opening use the isolation rope from the chimney connection set to make the plate air tight Slide the pipe E 150mm length 500mm into the sealing plate Slide this pipe so far that you will have enough space later on for assembling the line
3. 29 changing batteries There is no risk of electric shock as the low voltage supply is similar to that used in torches Always turn off the appliance before changing batteries Remote control 1 Remove the cover on the back of the remote control 2 Carefully remove the battery clip along the side Pay attention not to pull the wires 3 If necessary remove the old batteries and place the new ones 2 x LRo3 Alkaline long life 1 5 V 4 Click the battery clip into the remote control and close the cover 5 It might be possible that you have to set the transmission code after changing the batteries see 10 4 3 Note Batteries are chemical waste and should be disposed in accordance with local regulations 53 UK IRL 11 CLEANING AND SERVICE INSTRUCTIONS Important Turn off the fire and allow it to cool down before commencing cleaning It is recommended that the fire is inspected serviced by a competent person at least once a year To maintain the finish on the trim wipe with soft damp cloth only Do not use abrasive cleaners polish or solvents as these can damage the surface finish UK IRL 12 DISPOSAL OF THE PACKAGING AND THE APPLIANCE The appliance packaging is recyclable The packaging could include the following materials cardboard CFC free foam soft wood plastic paper These materials should be disposed responsibly and in conformity with government regulations Batt
4. fig 14 2 Remove the back panel by loosening the 4 screws B see fig 14 22 UK IRL 4 5 Fitting the firebox Points of attention for placement If possible first locate the appliance before assembling the flue If this is not possible then always use an extendible pipe before connection onto the appliance 1 Position the firebox in the fireplace opening You can adjust the height with the 4 adjustable feet 2 Make the gas connection according to the instructions also see gas connection chapter 4 1 3 Assemble the flue system onto the firebox see chapter 5 4 Check if applicable that the safety hatch seals the combustion chamber properly safety hatch fig 16 5 If necessary place the DC convection system also consult the instruction belonging to the DC construction set 6 Isolate the firebox with a ceramic blanket 25 mm Preferred choice for insulation is unbound insulation wool at 1000 C gives no smell 7 Place the log set see placing log set chapter 4 4 24 UK IRL 4 5 Fitting the firebox continuing ceramic O blanket ceramicO blanket J ceramic blanket S O ceramicO blanket ceramicO blanket fig 17 Spread the bags of embers imitation ashes provide with the appliance over the burner tray Attention No embers on the grid end between the logs and the burner tray Before placing the glass check the glass sealing
5. position This allows gas to enter control knob B The is the OFF position preventing gas entering the main burner if the pilot is lit The knob should be turned slowly anticlockwise This allows gas to enter the burner and be ignited by the pilot flame Once ignition has taken place the fire may be set to any level between min and max by adjusting the control knob B 1 Push in and turn the control knob A from anticlockwise to the setting small flame You will hear a ignition click Check that the pilot is lit if not repeat 2 Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable 3 Release the knob The pilot should remain alight 4 Turn the control knob A to the position 5 Turn knob B slowly anticlockwise the fire should then ignite 6 Adjust flames to the required level 49 UK IRL 10 3 To extinguish For the main burner turn the control knob B clockwise to position To disable knob B turn knob Ato the position To extinguish the pilot turn control knob A to position although it is in order lo leave the pilot permanently lit 10 3 1 When the pilot extinguishes Warning When the pilot extinguishes for whatever reason you should wait at least 5 minutes before trying to turn it on again Possible causes of pilot extinguish are Operating error Interference of the safety device Failure in the pilot flame system Contact a qualifie
6. to achieve the desired heating and flame effect You will hear a beep every time the receiver recognises a good signal If not so see 10 4 3 setting the right transmission code When the fire is not be used for a prolonged period turn off the pilot see 10 4 2 Push low till the burner goes out and you can hear the motor clicking To enable the remote control turn knob A to the position To extinguish the pilot turn control knob A to position although it is in order to leave the pilot permanently lit 51 UK IRL 10 4 3 Setting the right transmission code 52 he receiver has to learn the code from the transmitter which is already done at the factory However the code disappears if the receiver is disconnected from the mains for a longer period 1 Set the on off switch on the receiver to on 2 Push the mod button on the receiver and hold it for 3 seconds 3 The green control lamp will light up and stay on Repeat this step if it doesn t 4 Push a button on the remote control The control lamp on the receiver should now go out 5 Again push a button on the remote control The lamp starts flashing and will switch off eventually 6 The receiver now recognizes the remote control The remote control now functions 7 Check if you can hear a sound and the motor runs when you push a button on the remote control UK IRL 10 4 4 Changing the batteries AAA a T fig
7. types of appliances Widescreen interior Types Silence and Feeling Roundscreen interior Type Misty MV100 interior Type Whisper MV110 interior Types Spectra Nova and Cadra Nova Special features Realistic flame and glow effect because of the Log burner technology Room sealed appliance inlet and outlet are led to the outside using a natural draught concentric pipe system 100 mm 150 mm no power fan required No additional ventilation required Air supply and flue gases go to outside atmosphere through wall or roof A maximum horizontal extension of 6 meters is possible Remote Control option on all appliances Meets the essential requirements of the European Gas Appliance Directive GAD and carries the CE mark UK IRL 2 SAFETY AND GENERAL INFORMATION Before installation ensure that the local distribution conditions identification of the type of gas and pressure and the adjustment of the appliance are compatible This gas appliance is factory set and shall not be adjusted by the installer This appliance does not contain any component manufactured from asbestos or any asbestos related products The pilot and flame sensing device fitted to this fire is also a safety device If for any reason any part of the pilot assembly is to be replaced the entire assembly including the pilot burner thermocouple electrode and injector must be exchanged complete for a pilot assembly from the original ma
8. 21835 20900167 Log set 20773200 20774500 20772500 20786130 20773700 20773700 Spark wire 06017300 06017300 06017300 06017300 06017300 06017300 Receiver 20604000 20604000 20604000 20604000 20604000 20604000 Remote control 20603900 20603900 20603900 20603900 20603900 20603900 Adapter 20900142 20900142 20900142 20900142 20900142 20900142 Gas control 37003089 37003089 37003089 37003089 37003089 37003089 Motor remote control 37003086 37003086 37003086 37003086 37003086 37003086 Pilot burner assemb NG 20900145 20900145 20900145 20900145 20900145 20900145 Pilot burner assemb propane 20900154 20900154 20900154 20900154 20900154 20900154 Thermocouple 37002033 37002033 37002033 37002033 37002033 37002033 Spark electrode 06006600 06006600 06006600 06006600 06006600 06006600 Embers 20900019 20900019 20900019 20900019 20900019 20900019 Heat resisting paint spray for comb chamb 09000008 09000008 09000008 09000008 09000008 09000008 Set of glass clips 20900008 20900008 20900008 x X x Touch Latch assembly 40 28103900 28103900 28103900 x x X 8 3 TECHNICAL DATA Widescreen Silence en Feeling C11 C31 UK IRL Country UK
9. IRL UK IRL Category Wiss Usage Model type C11 of C31 C11 of C31 Heat input Hi kW 75 7 2 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30 37 Gas rate 15 C 1013 mbar m3 h 740 231 kg h 540 g Reference burner pressure mbar 17 22 Injector size mm 3X 1 45 3X 1 00 1X 1 30 Reduced input restrictor mm 1 8 1 1 Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30 Flue system MV size 100 150 100 150 Preinstalled flue restrictor mm 30 30 Gas control GV36 with GV36 without pressure reg pressure reg Remote control Adapter Vv 4 5 Batteries remote control 2x LRo3 1 5 V Alkaline Gas connection mm 8mm nut 18 mm nut and olive and olive Dimensions see table 1 41 UK IRL 8 3 TECHNICAL DATA MV100 Whisper and Spectra Nova Country UK IRL UK IRL Category Wise Wigs Model type C11 of C31 C11 of C31 Heat input Hi kw 75 75 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30 37 Gas rate 15 C 1013 mba m3 h 790 231 kg h 540 g Reference burner pressure mbar 17 22 Injector size mm 2X 1 40 3X 1 00 1X 1 30 Reduced input restrictor mm 1 8 1 1 Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30 Flue system MV size 100 150 100 150 Preinstalled flue restrictor mm 30 30 Gas control GV36 with GV36 without pressure reg pressure reg Remote control Voltage adapter V 4 5 Batteries 2x LRo3 1 5 V Alkaline Gas connection mm 8 mm nut 8 mm nut and olive and olive Weight i
10. al and vertical length When meeting an X and when the values are outside the table the combination is not allowed Normally the 30 mm flue restrictor is preinstalled Horizontal extension X combination not allowed o remove flue restrictor 5 Number is size in mm of the flue restrictor Effective height table 4 interior Cadra Nova o 0 1 2 3 4 5 6 7 8 9 10 11 12 Xxxx KK OOOO KK Misty with roundscreen Determine according to the table 5 the right total horizontal and vertical length When meeting an X and when the values are outside the table the combination is not allowed Normally the 30 mm flue restrictor is preinstalled Horizontal extension e n N o 0000 Xx MIE O O Oo XxX Xx KI X combination not allowed o remove flue restrictor Number is size in mm of the flue restrictor Aw o o Effective height table 5 interior Roundscreen lt M KK KK KOO OO OO X Xx KIO o 0 5 1 1 5 2 3 4 5 6 7 8 9 10 11 12 12 UK IRL 3 2 Flue requirements continuing 3 2 1 Terminal position Verify if the required terminal position meets the local installation regulations regarding disturbance good functioning and ventilation Also see safety requirements Note The terminal must be located so that the outlet is not obstructed If the flue terminal is located within 2 meters of a footway path or where people could come into contact with it then a suitable te
11. al burner check 1 Turn knob B to max clockwise 2 Turn the knob A more anticlockwise to the position large flame Now it is possible to light the main burner 3 Turn knob B anticlockwise to max The main burner should light Check for gas soundness at all joints with leak detection floud Check the ignition of the main burner on low and high setting Turn knob B clockwise till The main burner is off 6 Turn the knob A to The pilot should go out WS 32 UK IRL 6 3 Functional balanced flue check 1 Set the appliance on max input 2 Verify the flame picture this means no flames against the window the flame have to come besides the logs if not check the log layout 3 Check if the flames are yellow after 10 minutes of operation If you still have a blue flame or the appliance goes out check If the flue pipes are fitted correctly no leakage If the wall mounted terminal is placed with the correct side up If the correct flue restrictor is installed G EEN O OG 6 4 Check reference pressure The appliance is preset to give the correct heat input No further adjustment is necessary Fit a pressure gauge at the test point D to check the burner pressure The pressure should be checked with the appliance alight and at max input The setting pressure should be as s
12. d installer when the appliance goes off regularly 10 4 Remote control version 50 The remote control is only meant to regulate the flames from off till max it functions only when the pilot burner is ignited and knob A in big flame position It is therefore not possible to ignite the pilot flame with the remote control or to extinguish the pilot flame The radio frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria Denmark Finland and Greece Features Manual control will always remain possible The remote control is a radio frequency type and had been approved internationally The remote control generates a unique safety code every time you activate the transmitter its similar to those used in a car The remote control is easy to install retrospectively 10 4 1 To light faber fig 28 remote control 10 4 2 To extinguish i rA UK IRL Push in and turn the control knob A from anticlockwise to the setting small flame You will hear a ignition click Check that the pilot is lit if not repeat Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable Release the knob The pilot should remain alight Turn the control knob A to the position Set the on off switch on the receiver to on low flame C high flame Use high and low
13. e appliances Widescreen and Whisper 1 Open the ashtray door by pushing on the right side for the Silence Feeling and on the left side for the Whisper Remove the frame by loosening the screws A behind the door see fig 5 Lift and pull forward when you take it away 17 UK IRL 4 2 Preparing the appliances Widescreen and Whisper continuing oo OO A A fig 6 Remove the back panel by loosening the screws B see fig 6 fig 7 3 Remove the glass by removing the glass clamps C see fig 7 for instance with a screwdriver Careful when removing the glass Wear gloves Before placing the glass back be sure that there are no fingerprints on the glass it is not possible to remove those prints after you burn the appliance or a while they will be burnt in UK IRL 4 2 Preparing the appliances Widescreen and Whisper continuing C C C OO CFF fig 8 4 Take the box with the log set out of the combustion chamber 5 Place the right flue restrictor in the combustion chamber To determine the right flue restrictor see chapter 3 UK IRL ____ UK IRL 4 3 Preparing the appliance Misty 4 3 Preparing the appliance Misty continuing 4 Take the box with the log set out of the combustion chamber 5 Place the right flue re
14. eries are considered chemical waste The batteries should be disposed of responsibly and in conformity with government regulations Remove the batteries before disposing of the remote control Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities
15. essure reg Remote control Voltage adapter V 45 Batteries 2x LRo3 1 5 V Alkaline Gas connection mm 8 mm nut 8 mm nut Dimensions see table 1 and olive and olive 44 USER GUIDE UK IRL 45 UK IRL 9 SAFETY INSTRUCTIONS FOR THE USER 9 1 General safety instructions If a gas leak is found or suspected turn off the gas supply at the meter and contact your installer or gas emergency service These instructions should be read carefully and retained for future reference Do not use the fire with a broken or damaged glass The fire has a safety device which turns off the gas supply if there is a build up from flue gasses in the combustion room or a temporary gas cut off Wait at least 5 minutes before turning the appliance on again Contact a qualified installer when the appliance goes off regularly The appliance has been designed for heating purposes This means that all surfaces including the glass can become very warm over 100 degrees An exception to this is the lower side of the door and the control buttons Due to the newness of materials they may give off a slight smell for a period after initial lighting This is normal odours will disperse after a few hours use Do not place curtains clothing laundry furniture or other flammable materials nearby the appliance The required minimum distance is 100 cm Switch off the receiver of the remote control if you don t use the fire for a long t
16. faber Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 SILENCE FEELING WHISPER SPECTRA NOVA CADRA NOVA MISTY room sealed built in gas fireplace installation guide and user manual Log Burner Technology GLIN DAMPLEX LE 20 25 010 07 faber CONTENTS 1 INTRODUCTION 2 SAFETY INSTRUCTIONS 3 INSTALLATION REQUIREMENTS 3 1 Builders opening and surround 3 2 Requirements outlet and exhaust 4 INSTALLATION INSTRUCTIONS 4 1 Gas connection 4 2 Preparation of the appliance 4 3 Fitting the firebox 4 4 Placing of the wood set 5 INSTALLATION OF THE FLUE 5 1 Connection of the flue 5 2 Placing through existing chimney 5 3 Remote control 6 COMMISIONING 6 1 Check pilot ignition 6 2 Functional burner check 6 3 Functional balanced flue check 6 2 Check reference pressure 7 HANDING OVER 8 SERVICING 8 1 Routine annual servicing USER GUIDE 9 SAFETY INSTRUCTIONS FOR THE USER 10 CONTROLING THE APPLIANCE 11 CLEANING AND SERVICE INSTRUCTIONS 12 DISPOSAL OF THE PACKAGING AND THE APPLIANCE INDEX 1 LIST OF SPARE PARTS INDEX 2 TECHNICAL DATA UK IRL 17 17 17 24 26 27 27 28 30 32 32 32 33 33 34 35 35 45 46 48 54 55 40 41 UK IRL 1 INTRODUCTION Note these instructions should be read carefully and retained for future reference Please leave these instructions with the user This guide is concerning the following
17. flue system and terminal on damage and soundness visual inspection 35 UK IRL 8 1 1 Cleaning the glass Depending on the intensity of use you can get a deposit on the glass This can be removed with a special ceramic glass cleaner ceramic cook top cleaner as follows 1 Remove the front and the back 2 Clean the glass Handle the glass with clean hands wear gloves if possible 3 To fit the glass proceed in reverse order Make sure that the log set has been installed correctly before fixing the glass Attention Before placing the glass check the glass sealing rope is in good condition and makes an effective seal Be sure that there are no fingerprints on the glass It is not possible to remove those prints after you burn the appliance for a while they are burnt in Place the glass in front of the appliance and fix the glass frame or use the glass clamps 8 1 2 Cleaning the combustion chamber and burner You can clean the combustion chamber with a vacuum cleaner If the burner is visibly damaged this can affect the distribution of the flame if so then replace the burner 8 1 3 Propane conversion For conversion from propane to natural gas order for a propane burner unit Please give the serial number from the data plate when you order 36 UK IRL 8 1 4 Burner tray assembly 1 Remove the front glass log set grid and burner tray cover 2 Break the gas supply at the control valve 3 Unscrew the burner a
18. g batteries see chapter 10 4 4 5 Set the on off switch on the receiver to on Setting the right transmission code The receiver has to learn the code from the transmitter which is already done at the factory However the code disappears if the receiver is disconnected from the mains for a longer period 1 Push the mod button on the receiver and hold it for 3 seconds 2 The green control lamp will light up and stay on Repeat this step if it doesn t 3 Push a button on the remote control The control lamp on the receiver should now go out 4 Again push a button on the remote control The lamp starts flashing and will switch off eventually 5 The receiver now recognizes the remote control The remote control now functions 6 Check if you can hear a sound and the motor runs when you push a button on the remote control 31 UK IRL 6 COMMISSIONING functional checks 6 1 Check pilot ignition 1 Push in and turn the control knob A from anticlockwise to the setting small flame You will hear a tick meaning there is ignition Hold the knob in and wait for a few seconds while the air is purged 2 Bring the knob back in the start position and turn the knob several times to the position Check that the pilot has lit 3 Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable 4 Release the knob The pilot should remain alight fig 23 6 2 Function
19. hown at the technical data page 41 After checking the pressure turn off the appliance Remove the pressure gauge and close the sealing screw Re light the appliance Turn to max input and test around the test point D for gas soundness using a Suitable leak detection fluid 32 UK IRL 7 HANDING OVER final check and customer briefing 7 44 Instruct the customer on the full operation of the appliance 7 2 1 Advise the customer how to clean the appliance including the glass 7 2 2 Instruct the customer on the operation of the remote control including replacement of batteries and how to set the right transmissions code 7 2 3 Hand over these instructions including the user guide to the consumer 7 2 4 Recommend that the appliance should be serviced by a competent person at least once a year 34 UK IRL 8 SERVICING To ensure safe efficient operation of the appliance it is necessary to carry out routine servicing at regular intervals It is recommended that the fire is inspected serviced by a competent person at least once a year Important Turn off the gas supply before commencing any servicing Always test for gas soundness after refitting the appliance 8 1 Routine annual servicing 1 Clean if necessary the pilot system the burner the combustion chamber the glass 2 Check the log lay and replace the embers if applicable 3 Do the functional test as described at page 34 4 Check the
20. ime Do not let children use the remote control without supervision UK IRL IMPORTANT A suitable Fireguard conforming to BS6539 and BS6778 should be used with this appliance to protect children the elderly or infirm Care should also be taken with pets In your own interest and that of safety all gas appliances must be installed by competent persons Installation must be in accordance with National Regulations CORGI registered installers are required to work to recognised standards Note Since the appliance is a source of heat circulation of air occurs Therefore it is of importance that you do not use the appliance shortly after a renovation of the home Because of the natural circulation of air moist and volatile components from paint building materials carpet etc will be attracted These components can settle themselves down onto cold surfaces in the form of soot As on all heat producing appliances soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured This should be born in mind when installing the appliance 47 UK IRL 10 1 Lighting the fire 10 CONTROLLING THE APPLIANCE Knob A If the main burner or pilot light are extinguished for any reason do not attempt to relight the pilot within 5 minutes Contact a qualified installer when the appliance goes off regularly The control valve is behind the ashtray door Silence Feeling Whisper Open the ash
21. in pipe or soil pipe 300 mm H From an internal or external corner 600 mm Above ground roof or balcony level 300 mm J From a surface facing the terminal 600 mm K From a terminal facing the terminal 600 mm L From an opening in the carport e g 1200 mm Piue termina pasinons window into the dwelling M Vertically from a terminal on the same wall 1500 mm fig 3 N Horizontally from a terminal on the same wall 300 mm P From a vertical structure on the roof 600 mm Q Above intersection with roof 500 mm i a 155 UK IRL Example of how terminal position is measured Terminal C T table 4 I i r dimension B I i I a aa E I I PRERE er a i I Da ra A a I u T T T E rf I I p T A T ras A bA table 4 dimension C Ee E O T i L I T T I I T T T a rn E E T Cioe r E l i T i ig a EE table 4 PS EEE dimension A j i 4 i I I I fig 4 3 2 2 Using an existing chimney as air inlet 16 You can connect the appliance onto an existing chimney The existing chimney then functions as air supply where a flexible stainless steel liner to BS715 of 100 mm performs the flue function Re
22. ls carpet etc will be attracted These components can settle themselves down onto cold surfaces in the form of soot As on all heat producing appliances soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured This should be born in mind when installing the appliance 3 1 Builders opening and surround The appliance can be installed in the following situations In a non combustible fireplace or builders opening This could be either an existing builders opening or a new made prefab builders opening For the measurements see figure 1 and index Although the appliance is tested for installation without a hearth the appliance must not stand on combustible materials or carpets If the appliance is placed on a combustible floor then a fibrelux or similar heatproof board of 12 mm thickness should be placed under it Any under floor vents or openings within the builders opening should be sealed off Do not place the lintel surround or marble stone directly onto the appliance If possible apply a lintel made of cement or something similar Isolate the appliance with a ceramic blanket 25 mm See also chapter 4 Installation instructions Preferred choice for insulation is unbound insulation wool at 1000 C gives no smell UK IRL UK IRL 3 1 Builders opening and surround continuing If the builders opening is constructed out of non combustible composition board Fib
23. ncl packing material kg 75 75 Dimensions see table 1 8 3 TECHNICAL DATA MV150 Cadra Nova UK IRL Country UK IRL UK IRL Category Ug Usage Model type C11 of C31 Cu of C31 Heat input Hi kW 75 75 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30 37 Gas rate 15 C 1013 mbar m3 h 800 231 kg h 540 g Reference burner pressure mbar 13 25 Injector size mm 3X 1 50 3X 0 90 Reduced input restrictor mm 1 8 1 1 Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30 Flue system MV size 100 150 100 150 Preinstalled flue restrictor mm 30 30 Gas control GV36 with GV36 without pressure reg pressure reg Remote control Voltage adapter V 4 5 Batteries 2x LRo3 1 5 V Alkaline Gas connection mm 8 mm nut 8 mm nut and olive and olive Weight incl packing material kg 75 75 Dimensions see table 1 42 43 UK IRL ____ 8 3 TECHNICAL DATA Roundscreen Misty Country UK IRL UK IRL Category Worse Worse Model type C11 of C31 Ca of C31 Heat input Hi kW 8 5 8 5 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30 37 Gas rate 15 C 1013 mbar m3 h 900 231 kg h 540 g Reference burner pressure mbar 16 25 Injector size mm 3X 1 50 3X 0 95 Reduced input restrictor mm 1 8 1 1 Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30 Flue system MV size 100 150 100 150 Preinstalled flue restrictor mm 30 30 Gas control GV36 with GV36 without pressure reg pr
24. nufacturer only Ventilation This appliance is room sealed and doesn t require purpose provided ventilation 2 1 General safety It is the law in the UK that all gas appliances are installed by a competent person in accordance with the Gas Safety Installation and Use Regulations as amended the relevant British Standards for Installation work Building Regulations Codes of Practice and the manufacturers instructions The installation should also be carried out in accordance with the following where relevant BS5871 Part1 BS5440 Parts 1 amp 2 BS1251 Building Regulations Document J as applicable UK IRL Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Department In the Republic of Ireland installation should be carried out in accordance with 1S813 ICP3 1S327 Building Regulations Codes of Practice the manufacturers instructions and any other rules in force Failure to comply with the above could leave the installer liable to prosecution and invalidate the appliance warranty Safety instructions for the user see chapter 9 UK IRL 3 INSTALLATION REQUIREMENTS Note Since the appliance is a source of heat circulation of air occurs Therefore it is of importance that you do not use the appliance shortly after a renovation of the home Because of the natural circulation of air moist and volatile components from paint building materia
25. ove the flue restrictor When calculating on basis of the MV150 table nr 4 Combination not allowed When calculating on basis of the Roundscreen table nr 5 Combination not allowed 10 T 0 Table Silence and Feeling with interior Widescreen UK IRL Determine according to the table 2 the right total horizontal and vertical length When meeting an X and when the values are outside the table the combination is not allowed Normally the 30 mm flue restrictor is preinstalled Horizontal extension o 1 X combination 15 not allowed 2 o remove flue restrictor 3 4 Number is size in mm 5 of the flue restrictor v gt 6 D 7 E 8 9 10 11 table 2 12 interior Widescreen Table Whisper and Spectra Nova with interior MV100 Determine according to the table 3 the right total horizontal and vertical length When meeting an X and when the values are outside the table the combination is not allowed Normally the 30 mm flue restrictor is preinstalled Horizontal extension Effective height 0 1 2 3 4 5 6 7 8 9 10 11 12 at propane not allowed X combination not allowed o remove flue restrictor Number is size in mm of the flue restrictor table 3 interior MV100 11 UK IRL Table Cadra Nova with interior MV150 Determine according to the table 4 the right total horizont
26. quirements Any existing chimney used as an air supply must only service this appliance A chimney that has previously been used for solid fuel must be swept before use The existing chimney needs to be airtight The existing chimney needs to have an opening of min 150 xX 150 mm The chimney needs to be intact and well looked after Use the adjustable roof mounted terminal especially made for this and the chimney connection set The minimum distance between two terminals should be at least 450 mm 4 1 Gas connection UK IRL 4 INSTRUCTIONS FOR INSTALLATION Installation pipes should be in accordance with BS 6891 Pipe work from the meter to the appliance must be of adequate size The complete installation including the meter must be tested for soundness and purged as described in the above code A means of isolation must be provide in the supply to facilitate servicing The connection should be made in 8 mm copper or similar semi flexible tube max 1 meter Ensure that the gas pipe does not interfere with the removal or replacement of the burner tray of the controls The gas connection is nut and olive suitable for 8 mm pipe A amp B eben suround Sore pe trough suas c ai VV YE A B ZZZZZZZZZZZZZ martie fig 5 gas supply routes when fire is fitted in a deep surround 4 2 Preparing th
27. r Install the appliance Connect the flexible stainless steel liner onto the appliance using the 100mm pipe F as adapter If the distance from the flue outlet to the sealing plate is bigger then 300 mm you have to use a concentric pipe first Slide the outside pipe onto the appliance or concentric extension so that you have a air tight connection 29 UK IRL 5 3 Remote control if applicable The remote control is only meant to regulate the flames it functions only when the pilot burner is ignited It is therefore not possible to ignited the appliance with the remote control or to shut off the pilot flame The radio frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria Denmark Finland and Greece Features Manual control will always remain possible The remote control is a radio frequency type and has been approved internationally The remote control generates a unique safety code every time you activate the transmitter its similar to those used in a car The remote control is easy to install retrospectively 5 3 1 Installation remote control 1 Connect the mains adapter to the receiver box The adapter is set to the correct voltage in the factory 4 5V 2 Slide the receiver box into the holder g fig 22 3 Connect the wires to the gas valve see fig 22 4 Check that there are batteries in the transmitter See Replacin
28. relux and you install the appliance without a mantel then Ventilate the space above the appliance min 1000 mm Always fit the DC convection set mG The plaster of the outside has to be resistant to a high temperature Use therefore the plaster materials especially made for fig 1 this to prevent discoloring min 100 C temperature resistant If the appliance is to be fitted against a wall with combustible Builders opening mm Feeling Silence Whisper Spectra Cadra Misty cladding the cladding must be removed from the area covered by the Nova Nova surround A Opening width 960 960 780 780 680 710 Te opening reish 2 as 703 ole 798 890 The minimum height from the top surface of the fire to the underside pening aik 393 395 430 430 430 370 of any shelf made from wood or other combustible materials is as Shelf dimensions follows combustible D Man Height Shel fam For a shelf up to 150 mm deep Minimum height 350 mm top frame 350 350 350 350 350 350 fi ig 1 E Depth shelf max 150 150 150 150 150 150 Dimensions mm If the shelf depth is greater than 150 mm add 50 mm to the upper F Box width 880 880 750 750 650 698 clearance height for every 25 mm increase in shelf depth G Box depth 366 366 397 375 375 338 oT oe 2 715 879 Side clearance Minimum distance from the side of the fire frame Eliis siete 22i 5 794 24 149 to comb
29. rminal guard must be fitted Terminals located close to shared walkways footpaths etc could be subject to legal constraints and this should be pointed out to the customer before installation If in any doubt about flue location advice should be sought from local building control or if appliance related from the manufacturer including wherever possible a dimensioned sketch Avoid locating the terminal in close proximity to plastic materials such as gutters or other combustibles If this is unavoidable then a suitable deflector should be made Some important requirements for a good functioning are The wall mounted terminal has to be at a distance of at least 0 5 meters off Corners of the building Below eaves Balcony s etc unless the duct is dragged to the front side of the overhanging part The roof mounted terminal has to be at a distance of at least 0 5 meters of the sides of the roof excluded the ridge 13 UK IRL ____ UK IRL Flue terminal positions Table 6 Dimension Terminal position Balanced flue room sealed kW input 7 5 kW expressed in net Natural draught A Direct below an opening airbrick 300 mm opening windows etc B Above an opening airbrick 300 mm opening window ect C Horizontally to an opening airbrick 300 mm opening window etc D Below gutters soil pipes or drain pipes 500 mm E Below eaves 500 mm F Below balconies or car port roof 600 mm G From a vertical dra
30. rope is in good condition and makes an effective seal Be sure that there are no fingerprints on the glass It is not possible to remove those prints after you burn the appliance for a while they are burnt in Widescreen and Whisper Place the glass in front of the appliance and fix it with the glass clamps Replace the frame Misty Cadra Nova and Spectra Nova Place the door and fix it Check on visual leakages around the door sealing 10 Misty and widescreen Fix the back and top or door frame the back frame first 25 UK IRL 4 6 Placing the log set Never place extra elements of any kind into the combustion chamber To guarantee good combustion the log set may only be installed in the way specified by Faber International Any other arrangement can lead to soot on logs or window Do not use the fire with broken or missing logs 4 6 1 Placing the log set Widescreen Whisper Spectra Nova Misty and Cadra Nova 26 fig 18 fig 19 On the bottom of the logs is a identification eL location on the left side resting on the rear log eR location on the right side resting on the rear log e 1 dimple first log left placed over the burner and resting on the burner tray e 2 dimples placed in the middle over he burner and resting on the burner tray e 3 dimples the right side log placed over the burner and resting on the burner tray Attention Beware that there are no embers between the logs and the burner tray
31. sion This is the total horizontal flue length where e each elbow which is in the horizontal area counts for 2 meters e each 45 degree bend which is in the horizontal area counts for 1 meter e elbows and bends at the transition of horizontal to vertically are not to be counted e the wall mounted terminal counts for 1 meter UK IRL Example calculation 1 Calculation horizontal extension fig 2a Flue lenght C E 1m 1m 2m Elbows D 2m 2m Total horizontal extension 4m Measure or calculate effective height Hvert Flue lenght A 1m Roof mounted terinal 1m Total effective height 2m When calculating on basis of the Widescreen table nr 2 It is allowed Remove the flue restrictor When calculating on basis of the MV100 table nr 3 Allowed but without flue restrictor Remove the flue restrictor When calculating on basis of the MV150 table nr 4 Allowed but without flue restrictor Remove the flue restrictor When calculating on basis of the Roundscreen table nr 5 Allowed but without flue restrictor Remove the flue restrictor Example calculation 2 Calculation horizontal extension fig 2b Flue lenght J L 05 05 m Elbows K M 2m 2m 4m Terminal 1m Total horizontal extension 6m Vertical Flue lenght H 1m When calculating on basis of the Widescreen table nr 2 Combination not allowed When calculating on basis of the MV100 table nr 3 Allowed but without flue restrictor Rem
32. ssembly and take them out of the combustion chamber fig 25 Pilot assembly Burner Fixation plate Injector Gas control Receiver mM OoN D gt 8 1 5 Pilot thermocouple assembly Remove the burner tray as described above Now you have access to all the pilot and thermocouple parts 37 UK IRL 8 1 6 Gas control block O Governor fig 26 Adjusting screw pilot flame Inlet pressure test point GUO WwW D gt Burner pressure test point 38 UK IRL 8 1 7 Combustion test A BS7967 combustion analysis check should be carried out using an analyser to BS7927 positioned in the flue outlet A Ratio of CO CO2 should be less than 0 01 within 30 minutes 100ppm CO per 1 CO2 A reading of CO in the room centre should give a rise of less than 9ppm over ambient peak reading 39 UK IRL 8 2 LIST OF SPARE PARTS Description Company part Company Company part part part Company part Company part Surround antracite A9271453 Ag9270053 A9267753 AA9272853 A9274149 Ag274249 Glass 04508200 04508300 04508300 04509000 4509500 04509300 Glass below x x x x 04509600 04509400 Burner NG 20521808 20521808 20521808 20521808 20521808 20900166 Burner propane 20521835 20521835 20521835 20521835 205
33. strictor in the combustion chamber To determine the right flue restrictor see chapter 3 fig 10 1 Remove the door frame Lift and pull forward see fig 10 2 Open the ashtray door by pulling down bottom handle C 00 fig 12 fig 11 3 To open the door remove the screws C see fig 11 The door opening is limited if you need more space then remove the door lift and pull forward Be sure that there are no fingerprints on the glass It is not possible to remove those prints after you burn the appliance for a while they are burnt in 20 UK IRL ____ UK IRL 4 4 Preparing the appliances Spectra Nova Cadra Nova 4 4 Preparing the appliances Spectra Nova Cadra Nova continuing 4 Take the box with the log set out of the combustion chamber A 5 Place the right flue restrictor in the combustion chamber To determine the right flue restrictor see chapter 3 A fig 13 1 To open the door remove the screws A see fig 13 Open and remove the door lift and pull forward Be sure that there are no fingerprints on the glass It is not possible to remove those prints after you burn the appliance for a while they are burnt in o0 fig 15
34. tray door by pushing on the right side for the Silence Feeling and on the left side for the Whisper Misty Open the ashtray door by pulling down bottom handle with gas Knob B damper Cadra Nova and Spectra Nova Open by pushing the lip located on the right side in the gap between the ashtray door and the frame door flaps open A B 10 2 To light fig 27 control unit With control button A you can light the pilot With the control button B you can adjust the height of the flames see fig 27 UK IRL The is the OFF position preventing any gas from passing through the control valve to either the pilot burner or to the main burner By pressing the knob in it is possible to turn it anticlockwise The first function is to turn on the gas to the pilot this occurs just before reaching the position if the fire has not been lit for some time it may be necessary to hold the knob in this position for some seconds to clear the air from the pipe and allow gas to reach the pilot burner Once gas is available at the pilot continued rotation anti clockwise will cause the piezo igniter to spark This is accompanied by a click at the valve and should result in the pilot burner igniting Once the pilot is lit the control knob should be held pressed in for 10 seconds In this time the pilot flame will have heated the flame supervision thermocouple sufficiently to operate a hold on magnet within the valve Now turn the control knob A to the
35. ustible material 150 mm Frame height 678 678 720 703 803 905 Frame thickness 47 20 16 30 30 144 L Position flue behind frame 255 255 257 235 235 196 M Position flue from the back side box 111 111 140 140 140 142 the points A until C applies a tolerance from 0o mm and 5 mm fable 1 6 7 UK IRL UK IRL 3 2 Flue requirements Flue restrictor The appliance is of the type C11 C31 The appliance will need to be If applicable in the table is also stated the size of a flue restrictor supplied with the approved flue pipes and terminal it is not possible to This restrictor needs to be fitted in the combustion chamber when supply your own placing the appliance see chapter 4 2 Normally the smallest flue restrictor is fitted The minimum effective height of the flue system must be 0 5 or 1 meter depending on the appliance Terminal locations through the wall as well as through the roof See figure 3 Flue routing a horizontal extension with elbows is allowed for a maximum of 6 meters depending on the type and situation vertical max 12 meters Determine on the base of the table 2 and 3 depending on the type and terminal position if the desired situation is possible To establish this you will need to calculate The effective height this is the real difference in height between the upper side of the appliance and the terminal The total horizontal exten