1. cartridges are new have been properly flushed and both needle and follower register inadequate pressure or the LPA is sounding you may be experiencing inadequate water pressure or some restriction may exist in the inlet water line In either case the incoming water pressure must be improved to receive optimum filter life COMPLETE CARTRIDGE CHANGE INSTRUCTIONS CAN BE FOUND ON THE FILTER CARTRIDGE LABEL not for residential use for food service applications only cArtriDge cHAnge proceDure e Series prefilter cartridge change 1 Shut off power to equipment Shut off inlet water ahead of system 2 Push red relief valve Unscrew bowl Remove prefilter cartridge 3 Clean bowl with filtered water only NO SPECIAL CLEANERS 4 Feel head o ring If dry lubricate with high quality silicone lubricant 5 Install new prefilter cartridge in bowl Hand tighten bowl onto head 6 Turn on water Turn on power to equipment everpure carbon filter cartridge change 1 Shut off power to equipment Shut off inlet water ahead of system 2 Open flushing valve to relieve pressure 3 Hold head firmly and push upward Turn cartridge to left until it stops 4 Pull cartridge downward and out of head 5 Hold head firmly Align cartridge lug with label Insert new cartridge firmly into head 6 Turn cartridge right 90 until rotation stops 7 Repeat steps 3 6 for remaining cartridges
2. flushing 8 With flushing valve fully open open inlet water at full force for five minutes Close flushing valve 9 Turn on power to equipment preSSure gAugeS Low Inlet Pressure Adequate Inlet Pressure Low Outlet Pressure Adequate Outlet Pressure Sr X feeder cartridge change 1 Shut off power to equipment Shut off inlet water ahead of system 2 Press red pressure relief button on head 3 Unscrew bowl 4 Remove old cartridge 5 Feel bowl o ring if dry lubricate with silicone lubricant 6 Install new SS 10 cartridge into head 7 Hand tighten bowl into head 8 Turn on water 9 Press red pressure relief button until water comes out of valve port 10 Turn on power to equipment for installations in Massachusetts the commonwealth of Massachusetts plumbing code 248 cMr shall be adhered to consult your licensed plumber for installation of the system this system and its installation must comply with state and local regulations cArtriDge cHAnge DeterMinAtion Replace the prefilter cartridge whenever it becomes excessively dirty observed visually or by flow restriction Follow the change instructions provided with the cartridge Replace carbon filter cartridges when capacity is reached or when flow becomes inadequate but at least annually All carbon filter cartridges on multiple cartridge systems should be changed at the same time Change the SS 10 cartridge when pro
3. Selecting A Mounting locAtion 1 Give consideration to the weight of the unit when operating filled with water Operating weights of High Flow CSR Systems are Twin System 45 lbs 20 2 kg Triple System 47 lbs 21 2 kg Quad System 49 lbs 22 2 kg Quad Plus System 49 lbs 21 2 kg separate surge storage tank 60 lbs 27 2 kg 2 The location should allow for See figures 1 8 Minimum clearance of 21 2 under the cartridge s so it can be lowered for removal and replacement Adequate space for in and out water line connections Be near a drain for flushing and near a 110V outlet if the optional Everguard Low Pressure Alarm is used Additional mounting and floor space for the separate SR X Feeder and surge storage tank Quad Plus operAting SpecificAtionS combined Model name replacement cartridge flow rate capacity High Flow CSR Twin MC MC 3 3 gpm 12 5 lpm 18 000 gal 68 000 L High Flow CSR Twin MC2 MC2 3 3 gpm 12 5 lpm 18 000 gal 68 000 L High Flow CSR Twin XC XC 3 3 gpm 12 5 lpm 18 000 gal 68 000 L High Flow CSR Twin XC2 XC2 3 3 gpm 12 5 lpm 18 000 gal 68 000 L High Flow CSR Twin 4CB5 4CB5 3 3 gpm 12 5 lpm 12 000 gal 45 400 L High Flow CSR Twin 7CB5 7CB5 5 0 gpm 18 9 lpm 20 000 gal 75 700 L High Flow CSR Triple MC MC 5 0 gpm 18 9 lpm 27 000 gal 102 000 L High Flow CSR Triple MC2 MC2 5 0 gpm 18 9
4. agents such as chlorine ozone chloramines and other related components alteration installation or operation contrary to our printed instructions or by the use of accessories or components which do not meet Everpure s specifications Refer to the specifications section in the Installation and Operating manual for approved application parameters Our product performance specifications are furnished with each water treatment unit TO THE EXTENT PERMITTED BY LAW EVERPURE DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE TO THE EXTENT REQUIRED BY LAW ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR THE ENTIRE WATER TREATMENT UNIT As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing this product The quality of water supplies may vary seasonally or over a period of time and your water usage rate may vary as well Water characteristics can also differ considerably if this product is moved to a new location For these reasons we assume no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligations for us Further we assume no liability and extend no warranties express or implied for the use of this product with a non potable water source or a water source which does not meet the c
5. ater feed in Massachusetts a backflow preventer is required for this installation Connect one branch of the service water tee to the fountain beverage equipment Connect the other branch of the tee to the inlet of the SR X Feeder Connect the outlet of the SR X Feeder to the ice machine make up water not condenser water line and coffee brewing equipment The surge tank isolation and flushing valve is located at the end of the system header Using fittings and hose provided connect one branch of the valve to the surge storage tank Connect a hose from the other flushing branch and run to drain Note Some municipal plumbing codes and good sanitary practices require an air gap at the drain termination point 4 The surge storage tank is pre pressurized to 20 psi Check pressure and adjust as necessary 5 Install a manual shut off valve leading to the system for servicing and connect minimum 1 2 I D 3 4 for quad water line to the system inlet 6 The optional Everguard Low Pressure Alarm LPA consists of a pressure switch audible visual alarm box and a power adapter It is designed to detect a fixed low pressure approx 20 psi condition as an indication of loss of system outlet pressure either due to an intentional shut down or excess fouling of the water filters thus indicating the need for filter cartridge change out If the system is equipped with the LPA follow these steps Determine location of a
6. convenient 110 VAC outlet to plug in the LPA power adapter Remove the protective rubber cap from the pressure switch installed in the system header assembly Insert the wires from the LPA unit through the cap and connect them to the terminals on the pressure switch Either wire can be connected to either terminal Replace the cap Plug the LPA power adapter into an outlet The audible alarm should activate Push the reset switch to silence Unplug the LPA unit 7 Shut off the system inlet valve located on the inlet of the prefilter head 8 Check to be sure the o ring on the prefilter housing is sufficiently lubricated Use a good grade of silicone lubricant if needed Position the EC210 prefilter cartridge on guide seat in the bottom of the bowl Then thread the bowl into the head by hand Use a sump wrench to snug the bowl onto the head 9 Install only genuine Everpure carbon filter cartridge s into the filter head s following directions on the cartridge label or as shown in the Cartridge Change illustrations Install the SS 10 Scale Inhibitor cartridge into the SR X housing 10 Turn on inlet water to the filter system and check for leaks 11 Open the flushing valve and flush the cartridge s by running water through at full force for five minutes This will set the filtering media and purge any air and fines insuring maximum filter life See illustrations 12 After flushing close the flushing va
7. ct a minimum 1 2 I D line from this outlet to fountain beverage equipment The cross fitting has a flushing valve installed on the bottom Connect tubing to the flushing valve and run to drain Note Some municipal plumbing codes and good sanitary practices require an air gap at the drain termination point Figure 1 Twin EV3112 78 Rev E AP08 Installation and Operation Guide High Flow CSR Filter Systems Figure 2 Triple Figure 4 Quad Plus Figure 3 Quad Manufactured by Everpure Connect the outlet of the SR X Feeder to the ice machine make up water not condenser water line and coffee brewing equipment Proceed to step 4 3b For High Flow CSR Quad Plus System connect outlet to equipment served per the instructions be low Always use a NSF approved pipe dope or Teflon tape at all connections Use a backup wrench on all fittings while connecting to avoid stress on the system components Locate and mount the separate SR X Feeder between the High Flow CSR system and the ice machine Make up water not condenser water line and coffee brewing equipment A tee fitting is located in the system header before the surge tank isolation and flushing valve Using minimum 1 2 I D line connect the outlet of this tee to the fountain beverage and remote SR X Feeder line important install a tee in this service water line to separate the fountain water feed from the ice machine coffee brewer w
8. duct level in the cartridge drops below 1 2 from the bottom of the bowl The system pressure gauge or optional Everguard Low Pressure Alarm LPA provides a quick simple means of determining when the filter cartridge s should be checked Installed on the system outlet manifold the gauge or LPA can be used to monitor both dynamic flowing and static line pressure The cartridge s should be changed when the pressure gauge is in the red area while equipment is in operation and yet the needle shows adequate line pressure between cycles Observe the needle during the next equipment on cycle If the needle registers adequate pressure it can be assumed that the temporary low pressure condition was caused by a brief power failure or other incoming pressure disruption If the low pressure condition is not due to an external condition check change the prefilter first If the low pressure condition is still not corrected change the carbon filter cartridges for sales replacement components and service contact your everpure dealer or everpure llc 1040 Muirfield Drive Hanover Park Illinois 60133 800 323 7873 in europe Toekomstlaan 30 B 2200 Herentals Belguim in Japan Hashimoto MN Bldg 7F 3 25 1 Hashimoto Sagamihara Shi Kanagawa 229 1103 Japan Printed in U S A EV3112 78 Rev E AP08 technical Service 800 942 1153 www everpure com liMiteD WArrAnty coMMerciAl WAter treAtMent equipMent You have just purcha
9. lpm 27 000 gal 102 000 L High Flow CSR Triple XC XC 5 0 gpm 18 9 lpm 36 000 gal 136 000 L High Flow CSR Triple XC2 XC2 5 0 gpm 18 9 lpm 36 000 gal 136 000 L High Flow CSR Triple 4CB5 4CB5 5 0 gpm 18 9 lpm 18 000 gal 68 000 L High Flow CSR Triple 7CB5 7CB5 7 5 gpm 28 5 lpm 30 000 gal 113 550 L High Flow CSR Quad MC MC 6 6 gpm 25 2 lpm 36 000 gal 136 000 L High Flow CSR Quad MC2 MC2 6 6 gpm 25 2 lpm 36 000 gal 136 000 L High Flow CSR Quad Plus XC XC 6 6 gpm 25 2 lpm 48 000 gal 181 600 L High Flow CSR Quad Plus XC2 XC2 6 6 gpm 25 2 lpm 48 000 gal 181 600 L For individual cartridge specifications refer to cartridge literature temperature 35 100 F 2 38 C pressure 10 125 psi 0 7 8 6 bar non shock For cold water use only inStAllAtion 1 Use the predrilled mounting holes in the manifold bracket as guides Mark and drill anchor holes Mount securely See Figures 5 8 2 Shut off power to equipment If system is a High Flow CSR Quad Plus separate SR X Feeder and surge storage tank proceed to step 3b 3a Connect outlet ports of High Flow system to equipment served per the instructions below Always use NSF approved pipe dope or Teflon tape at all connections Use a backup wrench on all fittings while connecting to avoid stress on the system components The cross fitting before the SR X Feeder has a threaded outlet on top Conne
10. lve turn on power to equipment and plug the LPA if so equipped into the electrical outlet The system is ready for operation Figure 5 High Flow CSR Twin 25 80 ICE MACHINE COFFEE OUTLET 3 4 FNPT INLET 3 4 FNPT FOUNTAIN OUTLET 3 4 FNPT 25 59 Figure 6 High Flow CSR Triple 25 59 30 INLET 3 4 FNPT ICE MACHINE COFFEE OUTLET 3 4 FNPT FOUNTAIN OUTLET 3 4 FNPT Figure 8 High Flow CSR Quad Plus 29 69 OUTLET 3 4 FNPT INLET 3 4 FNPT ICE MACHINE COFFEE OUTLET 3 4 FNPT INLET 3 4 FNPT INSERT TEE FITTING ONE OUTLET TO FOUNTAIN ONE OUTLET TO SRX 31 38 Figure 7 High Flow CSR Quad 34 INLET 3 4 FNPT ICE MACHINE COFFEE OUTLET 3 4 FNPT FOUNTAIN OUTLET 3 4 FNPT 25 69 Check for compliance with state and local laws and regulations The Commonwealth of Massachusetts Plumbing Code 248CMR shall be adhered to Consult your local licensed plumber for installation of this system Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts fluSHing for maximum life all carbon filter cartridges must be flushed for five minutes at full flow before use All neW cArtriDgeS MuSt Be fluSHeD After eAcH cArtriDge cHAnge Before Being put into SerVice If the
11. onditions for use described in the owner s guide or performance data sheet for this product OUR OBLIGATIONS UNDER THIS WARRANTY ARE LIMITED TO THE REPAIR OR REPLACEMENT AT EVERPURE S DISCRETION OF THE FAILED PARTS OF THE WATER TREATMENT UNIT AND WE ASSUME NO LIABILITY WHATSOEVER FOR DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL SPECIAL GENERAL OR OTHER DAMAGES Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty lasts so the above limitation may not apply to you Similarly some states do not allow the exclusion of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Consult your telephone directory for your local independently operated Everpure dealer or write Everpure for warranty and service information replAceMent pArtS Contact your local Everpure dealer for filter cartridges or system replace ment parts Description part number Inlet outlet pressure gauge EV3114 09 Inlet flushing valve EV3114 07 O ring for prefilter or SR X EV3112 40 Prefilter bowl EV3112 38 SR X bowl EV3112 39 LPA pressure switch EV3016 41 Wrench EV3112 41 System Tested and Certified by NSF International against NSF ANSI Standards 42 and 53 for the reduction of Standard No 42 Aesthetic Effects Chemical Reduction Taste and Od
12. or Chlorine Mechanical Filtration Particulate Class I 99 2 reduction of particles one half micron and larger in size Standard No 53 Health Effects Mechanical Filtration Turbidity MC MC2 only Cyst MC MC2 XC XC2 only Asbestos MC MC2 only
13. sed one of the finest water treatment units made As an expression of our confidence in Everpure products this product is warranted against defects in material and workmanship to the original end user when installed in accordance with Everpure specifications The warranty period commences from the date of purchase and is administered as follows for a period of one yeAr replaceable elements i e filter amp water treatment cartridges for a period of fiVe yeArS the entire system excluding replaceable elements this is for material amp workmanship not filter or water treatment cartridge life The unit must be used in operating conditions that conform to Everpure s recommended design guidelines This warranty will not apply if the unit has been modified repaired or altered by someone not authorized by Everpure if a part described above is found defective within the specified period you should notify everpure technical service at the phone number listed below Any part found defective within the terms of this warranty will be repaired or replaced at everpure s discretion by your local dealer or everpure technical service you pay only freight from our factory and local dealer charges Any repaired or replaced warranty item will be incorporated under the original warranty terms of the existing system We are not responsible for damage caused by accident fire flood freezing Act of God misuse misapplication neglect oxidizing