1. Follow these steps 1 Connect the built in video cable into the 15 pin connector on the back of your computer and tighten the two screws 2 Connect the power cord into your LCD monitor s power input socket 3 Plug the other end of the power cord into the power output socket on your PC 31MY02 Envision Before You Operate the Monitor EN 5100e Adjusting the Viewing Angle For optimal viewing adjust the monitor s angle to Do not touch the LCD screen when you your own preference change the angle It may cause damage or e Hold the stand firmly when you change the breakage monitor s angle e Be careful to avoid pinching your hand in the You can adjust the monitor s angle from swivel base 5 to 45 EN 5100e 8 31MY02 Envision Operating Instructions EN 5100e Front Panel Buttons H 60KHz R OO B O OSD Window Power Button eralki Auto Power Indicator Brightness Menu Contrast Auto Press this button to automatically set o Power Indicator A green light indicates ao the H Position V Position Clock and Focus that the monitor is on An orange light settings indicates that the monitor is in Off mode D Brightness Press this button to adjust the gt Power Press this button to turn the x picture s brightness If the OSD window is monitor on or off The power indicator will open this button allows you to move within ligh
2. amp Bright The panel used on this product has a total of 2 359 296 sub pixels So even the maximum allowed of 6 bad sub pixels would only amount to a very small 0 00025 of the total sub pixels Missing one of the primary colors RED GREEN or BLUE e Inspect the video cable and make sure that none of the pins are bent e Make sure the video cable is properly connected to the computer EN 5100e 12 31MY02 Envision Technical Support FAQ EN 5100e Problem Possible Solution Screen image is not centered or sized properly Adjust the CLOCK and FOCUS settings or press the AUTO button to automatically re configure the monitor s settings Picture has color defects white does not look white e Adjust the settings for Red Green and or Blue colors or select a different color temperature 65 6500 K or 78 7800 K Poor brightness or contrast e The life time of the back light is limited After 20 000 hours the luminance of the light has been reduced to half of its original value Please send the monitor to an authorized service agent for service Horizontal or vertical disturbances on the screen e Adjust the CLOCK and FOCUS settings or press the AUTO button to automatically re configure the monitor s settings e Use Win 95 98 shut down mode CLOCK pixel frequency controls the number of pixels scanned by one horizontal sweep If the frequency is not cor
3. the party responsible for compliance could void the user s authority to operate the equipment 2 Shielded interface cables and AC power cord if any must be used in order to comply with the emission limits 3 The manufacturer is not responsible for any radio or TV interference caused by unauthorized modification to this equipment It is the responsibility of the user to correct such interference As an ENERGY STAR Partner Envision Peripherals Inc has determined that this product meets the ENERGY STAR guidelines for energy efficiency Warning To prevent fire or shock hazard do not expose the monitor to rain or moisture Dangerously high voltage is present inside the monitor Do not open the cabinet Refer servicing to qualified personnel only 31MY02 Envision Precautions Do not use the monitor near water e g neara bathtub washbow l kitchen sink laundry tub swimming pool or in a wet basement Do not place the monitor on an unstable cart stand or table If the monitor falls it can injure a person and cause serious damage to the appliance Use only a cart or stand recommended by the manufacturer or sold with the monitor If you mount the monitor on a wall or shelf use a mounting kit approved by the manufacturer and follow the kit instructions Slots and openings in the back and bottom of the cabinet are provided for ventilation To ensure reliable operation of the monitor and to protect it from o
4. 0 x 400 70 Hz 800 x 600 72 2 Hz 640 x 350 70 Hz 800 x 600 75 Hz 720 x 400 70 Hz 832 x 624 74 5 Hz 640 x 480 72 8 Hz 1024 x 768 60 Hz 640 x 480 75 Hz 1024 x 768 70 Hz 640 x 480 66 67 Hz 1024 x 768 75 Hz 800 x 600 56 3 Hz 1024 x 768 74 92 Hz EN 5100e 14 31MY02 Envision Appendix EN 5100e Specifications Plug amp Play VESA DDC1 LCD Driving TFT Color LCD ABIM Panel system Size 15 0 38 1 cm Input Connector D Sub 15 pin Input Video Signal Analog e B 0 7 Vpp Pixel pitch 0 01 0 3 mm H e y 75 OHM Positive 0 01 0 3 mm V Maximum Screen Size Horizontal Viewable 100 H 80 V 12 0 304 1 mm angle Vertical 9 0 228 1 mm Input Response 40 milliseconds time P 100 264 VA Video Red Green Blue datzate Ge SG Analog Interface Separate SARR Environmental Operating Temp Syne Considerations 32 to 122 F H Frequency 30 kHz 60 kHz 0 to 50 C V Frequency 50 75 Hz Storage Temp 13 to 140 F Display Colors 16 7 million colors Dot Clock 100 MHz Maximum Resolution 1024 x 768 pixels EN 5100e 25 to 60 C Operating Humidity 10 to 90 Weight 9 9 Ibs 4 5 Kg 15 31MY02 Envision Appendix EN 5100e Specifications continued Optimal Viewing Mode 1024 x 768 x 75 Hz Front Panel Buttons Auto Brightness 15 7 in Contrast 398mm P
5. 100e Remove Package Contents The box that your monitor was shipped in should have included the following items 1 EN 5100e LCD Monitor 2 Power Cord 3 Windows 95 98 2000 ME INF Driver Disk 31MY02 Envision Before You Operate the Monitor EN 5100e Connecting the Wires Using the Power Cord Supplied Connect the built in video cable into the 15 pin connector on the back of your computer and tighten the two screws Connect the power cord into your LCD monitor s power input socket Plug the other end of the power cord into a grounded AC outlet or UL approved power strip EN 5100e Caution Make sure the power cord is the correct type that is required in your area This LCD monitor has a universal power supply that allows operation in either 100 120V AC or 220 240V AC voltage areas no user adjustment is required If the AC outlet is not grounded with three holes install the proper grounding adapter not supplied 31MY02 Envision Before You Operate the Monitor EN 5100e Connecting the Wires Using An Optional Power Cord Not Supplied The power cord supplied with your monitor can only be connected to a grounded electrical wall socket or power strip If you wish to connect your monitor to a power supply using the power input socket on the back of your computer you must purchase a power cord with CEE 22 terminated connectors see illustration above EN 5100e
6. Envision EN 5100e EN 5100e 15 inch TFT LCD Monitor User s Manual by Envision Peripherals Inc www ENVISIONmonitor com Before operating your monitor please read this manual thoroughly Env s on EN 5100e 1 31MY02 Envision FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help EN 5100e For Your Safety EN 5100e Notice 1 The changes or modifications not expressly approved by
7. Please refer all servicing to qualified service personnel To ensure satisfactory operation use the monitor only with UL listed computers which have appropriately configured receptacles marked between 100 240 V AC Min 3 5A The wall socket should be installed near the equipment and should be easily accessible 31MY02 Envision Special Notes on LCD Monitors The following symptoms are normal with an LCD monitor and do not indicate a problem e Due to the nature of the fluorescent light the screen may flicker during initial use Turn off the Power Switch and then turn it on again to make sure the flicker disappears e You may find slightly uneven brightness on the screen depending on the desktop pattern you use e The LCD screen has effective pixels of 99 99 or more It may include blemishes of 0 01 or less such as a missing pixel or a pixel lit all of the time e Due to the nature of the LCD screen an after image of the previous screen may remain after switching from an image that has been displayed for hours This after image could require several hours to disappear e The life of the fluorescent light used in the LCD monitor is approximately 20 000 hours Contact your dealer or EPI service center for replacement when the screen is dark flickering or not lighting up Never attempt to replace it by yourself EN 5100e For Your Safety EN 5100e General Notes e Do not install the monitor near heat sou
8. al Support FAQ EN 5100e Problem Possible Solution Power LED is not ON e Make sure the power button is ON e Make sure the power cord is properly connected to a grounded power outlet and to the monitor No Plug amp Play e Confirm that your computer is Plug amp Play compatible e Confirm that your video card is Plug amp Play compatible e Inspect the video cable and make sure that none of the pins are bent e Make sure the Envision monitor drivers are installed ENVISION monitor drivers are available at www ENVISIONmonitor com Picture is fuzzy e Adjust the Contrast and Brightness settings Picture bounces or a wave pattern is present in the picture e Move electrical devices away from the monitor They may be causing electrical interference Power LED is ON green or orange light is ON but there is no video or picture e Press a key on the keyboard or wiggle the mouse to re activate the monitor e Make sure the video cable is properly connected to the computer e Inspect the video cable and make sure none of the pins are bent e Make sure your computer is operating correctly by pressing the CAPS LOCK key and observing whether the CAPS LOCK light turns ON or OFF Dead Pixel Criteria In order to provide the highest performing products EPI has set the following limits as to the maximum allowable number of bad pixels 4 Bright Sub pixels or 4 Dark Sub pixels or combination of 6 Dark
9. e the monitor alone for 10 2 Press the lt or gt buttons until the desired seconds If you want to adjust any other function is highlighted function repeat steps 2 4 3 Press MENU to open the function s window Note When the OSD window is open the input 4 Press the lt or gt buttons to change the settings of the function EN 5100e signal timing settings appear at the top H stands for horizontal frequency and V stands for vertical frequency 10 31MY02 Envision Plug amp Play DDC1 2B Feature This monitor is equipped with VESA DDC1 2B capabilities according to the VESA DDC STANDARD It allows the monitor to inform the host system of its identity and depending on the level of DDC used communicate additional information about its display capabilities The communication channel is defined in two levels DDC1 and DDC2B The DDC1 is a unidirectional data channel from the display to the host that continuously transmits EDID information The DDC2B is a bidirectional data channel based on the I C protocol The host can request EDID information over the DDC2B EN 5100e Operating Instructions 11 EN 5100e How to Install INF amp ICM File 1 Insert the Windows 95 98 2000 ME XP INF Driver Disk into your floppy drive 2 Follow the Add New Hardware Wizard instructions on the screen 3 If the wizard asks for the location of the driver file select drive A and press Next 31MY02 Envision Technic
10. ower Switch bk MENU Exit 15 6 in External Functions Contrast 397 mm Controls Brightness Focus COD Clock 7 5 in H Position 190mm e V Position Auto Center 6500 K 7800 K RGB Color temp Reset Exit EPA ENERGY Yes are STAR is Kg Power Consumption 25 Watts Maximum Regulatory UL CSA FCC Compliance TUV GS CE EN 5100e 16 31MY02 Envision Appendix EN 5100e Factory Preset Timing Table standard fics epena bebe VGA 720 x 400 31 47 kHz 70 Hz 640 x 480 31 47 kHz 60 Hz 640 x 480 35 00 kHz 66 6 Hz 640 x 480 37 50 kHz 75 Hz SVGA 800 x 600 37 879 kHz 60 Hz 800 x 600 46 875 kHz 75 Hz 832 x 624 49 725 kHz 75 Hz XGA 1024 x 768 48 363 kHz 60 Hz 1024 x 768 56 476 kHz 70 Hz 1024 x 768 60 02 kHz 75 Hz 1024 x 768 60 241 kHz 74 9 Hz EN 5100e 17 31MY02 Envision Appendix EN 5100e Connector Pin Assignment Pin Number Description Pin Number Description 1 Red 9 5V 2 Green 10 Detect Cable 3 Blue 11 NG 4 Ground 12 DDC Serial Data 5 Ground 13 H Sync 6 R Ground 14 V Sync 7 G Ground 15 DDC Serial Clock 8 B Ground 15 Pin Color Display Signal Cable EN 5100e 18 Pee
11. rces such as radiators or air ducts Do not place monitor in direct sunlight or in areas with excessive dust mechanical vibration or shock e Save the original shipping carton and packing materials in case you need to ship your monitor Be sure to repackage your monitor as it was originally packed at the factory e Periodically clean your monitor with a soft cloth Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution Never use strong solvents such as thinners benzene or abrasive cleaners since these will damage the cabinet Always unplug the monitor before cleaning it Using the Right Power Cord The supplied power cord is a NEMA 5 15 style plug It is UL listed and CSA labeled for 125 volts AC If the monitor will be connected to your computer s power outlet use a minimum No 18 AWG type SJT or SVT three conductors cord with one end terminating with a male grounded plug rated 10A 250V CEE 22 The other end must terminate with a molded on type connector body rated 10A 250V having standard CEE 22 female configuration 31MY02 Envision Installing amp Removing the Base E Install Jenny General Features 38 1cm 15 TFT Color LCD Monitor Crisp Clear Display for Windows 1024 X 768 75Hz Maximum amp Recommended Resolution EPA ENERGY STAR Ergonomic Design Space Saving Compact Case Design EN 5100e Before You Operate the Monitor EN 5
12. rect the screen shows vertical stripes and the picture s width is incorrect FOCUS adjusts the phase of the pixel clock signal With a wrong phase adjustment the picture has horizontal disturbances with very light screen images Note For FOCUS and CLOCK adjustment use dot pattern or Win 95 98 shut down mode pattern Error Message Possible Solution Cable not connected e Make sure the video cable is properly connected to the computer If the connector is loose tighten the connector s two screws e Inspect the video cable and make sure that none of the pins are bent EN 5100e 13 31MY02 Envision Technical Support FAQ EN 5100e Error Message Possible Solution Input not supported e Your computer has been set to an incompatible display mode Right click on the desktop and choose Properties Click the Settings tab then set your computer s display mode to one of the settings listed in the resolution chart below Unsupported mode try different video card setting e Your computer s resolution is out of VESA specifications Right click on the desktop and choose Properties Click the Settings tab then set your computer s display mode to one of the settings listed in the resolution chart below Resolution Chart Resolution Vertical Resolution Vertical in pixels Frequency in pixels Frequency 640 x 480 60 Hz 800 x 600 60 3 Hz 64
13. t up the window and select desired functions On screen Display OSD Press the ox 8 m lt gt Contrast Press this button to adjust the S MENU button to open the OSD window picture s contrast If the OSD window is Tea at and adjust settings on your monitor open this button allows you to move within See next page the window and select desired functions MENU Press this button to open the OSD window or exit from the OSD window MENU EN 5100e 9 31MY02 Envision Operating Instructions EN 5100e Adjusting the OSD Settings Focus Brightness Adjusts the picture s Adjusts focus pixel clock signal Contrast brightness Clock Adjusts the Adjusts clock pixel frequency picture s contrast H Position Adjusts the horizontal position of the picture Red Adjusts the intensity of red Green Adjusts the intensity of green V Position Adjusts the vertical position of the picture Blue Adjusts the Language intensity of blue Adjusts the language selection Exit Color Temp Saves changes and OSD disappears Adjusts the color temperature to 7800 K x 0 296 y 0 311 Reset Clears the current configuration and reapplies auto configuration Color Temp Adjusts the color temperature to 6500 K x 0 313 y 0 329 1 Press the MENU button to open the OSD 5 To save and exit highlight the EXIT icon and window press MENU or leav
14. verheating be sure these openings are not blocked or covered Do not place the monitor on a bed sofa rug or similar surface Do not place the monitor near or overa radiator or heat register Do not place the monitor in a bookcase or cabinet unless proper ventilation is provided The monitor should be operated only with the type of power source indicated on the label If you are not sure of the type of power supplied to your home consult your dealer or local power company EN 5100e For Your Safety EN 5100e The monitor is equipped with a three pronged grounded plug a plug with a third grounding pin As a safety feature this plug will only fit into a grounded power outlet If your outlet does not accommodate the three wire plug have an electrician install the correct outlet or use an adapter to ground the appliance safely Do not defeat the safety purpose of the grounded plug Unplug the unit during a lightning storm or when it will not be used for long periods of time This will protect the monitor from damage due to power surges Do not overload power strips and extension cords Overloading can result in fire or electric shock Never push any object into the slot on the monitor cabinet It could short circuit parts causing a fire or electric shock Never spill liquids on the monitor Do not attempt to service the monitor yourself opening or removing covers can expose you to dangerous voltage and other hazards