1. screws from the existing wall Figure 2 TO 120VAC ae alte p ae euch Pulli switch out rom wall SOURCE HOT speed control is rated for 3 0 amps 3 Disconnect wire from existing fan provided onto the speed control rotate counter clockwise to the at 120 volts To avoid erratic speeds wall switch Figure 1 Using the two 6 32 screws full OFF position supplied with the faceplate screw the faceplate and speed control to the wall outlet box Figure 3 and possible damage to your ceiling fan use this control only with the fans pull chain switches set to their high speed settings 9 Restore power at the main fuse box or circuit breaker panel CAUTION For fans equipped with built in variable speed devices These devices must be set at their WALL OUTLET BOX Installation 1 Before disconnecting power ensure that the fan is set at the a _ BOK MOA Aa TEN ror aes highest speed Figure 1 cane fol abl n peed i u nly be made wi NOTE Electric connections 4 Set the SW93 Quietset Dual Fan A Quietset in the OFF position should be in accordance with the Control in the off position full Changing or switching these National Electrical Codes and all counter clockwise and pull off settings while the fan control is in Local Codes Before starting the knob operation could damage the disconnect power to the circuit at Sulecereean control the fuse box or circuit breaker oe CONTROL panel ees FACEPLATE Figure 3
2. OPERATION NOTE Fan control knob turns fan on at maximum speed to assist motor start up Fan speed decreases with clockwise rotation Set the fans on their HIGH speed pull chain settings Then use your speed control to select any of the 3 speeds plus OFF IMPORTANT Always have the fan switch set to HIGH speed before using the wall control To avoid accidental pull chain use shorten chain by cutting it 1 below switch body The SW93 Quietset Dual Fan Control turns any set of two Emerson CF Series Ceiling Fans into three speed fans NOTE Fully counter clockwise is OFF The three fan speeds are selected by rotating the knob one position at a time clockwise LIMITED WARRANTY What The Warranty Covers All products covered by this Owner s Manual are warranted against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is All components are covered by this warranty for one year from the date you purchased your fan control ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Company Do To Correct Problems Emerson Company will replace a defective Emerson Fan Control at no charge to you We will ship the repaired product or replacement to you at no charge but you are responsible for all costs or removal rei
3. nstallation and shipping of the product to Emerson How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE FAN CONTROL TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Company 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request e To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Fan Control should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Company e Use of parts or accessories not authorized by Emerson Company e Mishandling improper installation modifications or damage to your wall control while in your possession or e Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and a
4. ny implied warranty of merchantability or fitness for a particular purpose are voided when e The original purchaser or user ceases to own the product or e The ceiling fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Company REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state EMERSON ga Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Printed in U S A 5 97 Part No F40BP72090000 Form No BP7209 CAUTION Read all instructions carefully before installation Sa
5. ve this Owner s Manual for future reference Model No SW93 WHITE IVORY QUIETSET DUAL FAN CONTROL SINGLE POLE 3 SPEED FAN MOTOR CONTROL MAXIMUM 3 0 AMP 120VAC 60HZ I EMIZERSON FAN CONTROLS SW93 Quietset Dual Fan Control Owner s Manual Form No BP7209 Printed in U S A 5 Connect the BLACK wire from 6 Connect the BLACK wire from Safety Instructions the Quietset to the fan motor lead the Quietset to the 120VAC hot WARNING To avoid fire shock and serious personal injury with a wire connector provided wire with a wire connector follow all instructions carefully Figure 2 provided 1 Read your Owner s Manual carefully Retain Owner s Manual for NOTE Use wire connectors future reference supplied to secure electrical 2 To avoid possible electrical shock be sure electricity is turned off connections at the main fuse or circuit breaker box before wiring TO NEUTRAL TO FAN MOTOR LOAD 3 Make certain no bare wires are exposed outside the wire connectors 4 Do not mount speed control near heat producing equipment 5 All wiring must conform to National and Local Electrical Codes If you do not have enough electrical knowledge have a licensed electrician install the control WARNING Use of this control with some ceiling fans could result in fire shock and serious personal injury Use this speed control only with Emerson CF series ceiling fans General 2 Remove the faceplate and