Emerson NetXtend PDC Series with NTI Technology Brochures and Data Sheets
Contents
1. 6999 Fax 440 246 4876 Web EmersonNetworkPower com EnergySystems Emerson Network Power The global leader in enabling Business Critical Continuity EmersonNetworkPower com HB Ac Power E Embedded Computing E Outside Plant E Racks amp Integrated Cabinets E connectivity E Embedded Power E Power Switching amp Controls Ml Services E Dc Power Monitoring E Precision Cooling Surge Protection 2009 Emerson Network Power Energy Systems North America Inc All rights reserved Code OSP 128400 May 2009
2. and power integrated racks and enclosures power switching and controls monitoring and connectivity All solutions are supported globally by local Emerson Network Power service technicians For more information on Emerson Network Power s full suite of solutions specifically supporting the communications network infrastructure including NetSpan NetReach and NetXtend outside plant enclosures and equipment NetSure DC power systems and turnkey services visit EmersonNetworkPower com EnergySystems Learn more about Emerson Network Power products and services at EmersonNetworkPower com This publication is issued to provide outline information only which unless agreed by Emerson Network Power Energy Systems North America Inc in writing may not be used applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned Emerson Network Power Energy Systems North America Inc reserves the right to alter without notice the specification design or conditions of supply of any product or service Emerson Emerson Network Power Business Critical Continuity NetSpan NetReach NetXtend and NetSure are trademarks of Emerson Electric Co and or one of its subsidiaries Emerson Network Power Energy Systems World Headquarters 4350 Weaver Parkway Warrenville IL 60555 USA Toll Free 800 800 1280 USA and Canada Telephone 440 246
3. E Outside Plant for Business Critical Continuity NetXtend PDC Series with NTI Technology Integrated Enclosure Solution EMERSON Network Power Key Features V3 SHIELD NTI Technology adds thermal protection at the board level eliminating thermal runaway and allows actual peak pulse current to be handled by the suppression module Integrated design minimizes footprint maximizes system performance and reduces installation time 30 or 42 position load center options provide wiring configuration flexibility Fully redundant two stage surge suppression provides unmatched power protection Easy access design simplifies module upgrades or replacement Main disconnect switch for utility and optional generator sources allows easy serviceability Optional Automatic Transfer Switch or Slide Bar Transfer Switch provides generator source capabilities SAD technology provides fast clamping and high energy handling Remote status indication allows long distance monitoring Field replaceable modules are stacked side by side for easier installation and indication Independent visual LED status indication on each module for convenient protection status As a stand alone solution or as part of a comprehensive power protection plan the PDC series provides the ultimate in power delivery and power protection The NetXtend PDC Series of integrated enclosures offer
4. ermal Overcurrent amp overvoltage thermal A EMERSON Network Power Transfer Switch Specifications Poles 2 Voltage nominal 220 240 VAC single phase 3 wire Frequency nominal 60 Hz Current 200 Amps Generator Rating maximum 48KW Withstand Close On Current 10 000 Amps RMS Symmetrical amps 240 VAC max for any circuit breaker manufacturer or type per National Electrical Code NEC NFPA 70 Power Terminal Wire Sizes 200 Amp unit One 8 to 3 0 AWG Cu copper wire must be used for full 200 Amp rating Safety Compliance UL 1008 transfer switch equipment Controller The NetXtend PDC Series incorporates several parameters that can be set according to system design preferences This allows for a wide range of flexibility in setting thresholds and timing options with the standard base product The standard controller utilizes simple push button operation for testing and exer ciser time set Voltage and Frequency Sensing Differential Voltage Sensing All phases of utility source Voltage Nominal 220 240 VAC Normal Source Voltage Drop Out 204 VAC Normal Source Pick Up 216 VAC Emergency Source Voltage Drop Out 180 VAC Emergency Source Voltage Pick Up 216 VAC Emergency Source Frequency Drop Out 51 VAC Emergency Source Frequency Pick Up 57 VAC EMERSON Network Power Emerson Network Power provides a complete range o
5. f communications network infrastructure solutions and services built on an industry leading reputation for quality reliability and value Generator Exercise Control Standard Automatic Generator Exerciser Repeat Time Every 7 days Duration Generator Control Contacts Gold plated engine start stop contacts 20 minutes with or without load transfer Rated 5 Amps 28 VDC 120 VAC Transformer Voltage Adjust HI Nominal phase to phase voltage LOW Shifts all voltage settings down 4 2 from nominal Time Delay Parameters and Control Override Momentary Normal Source Outage 3 seconds Transfer to Generator Time Delay 0 5 minutes adjustable Override Momentary Generator Initial Loading Events 4 seconds Re transfer to Normal Source Time Delay 1 second to 30 minutes adjustable Unloaded Generator Cool Down Run Time Delay 5 minutes Optional Programmable Engine Exerciser In addition to the standard programma ble weekly exercise function an optional programmable controller provides the ability to individually control the start time and duration of test for each day of the week An internal NiCad battery retains program memory for up to 150 hours if failure of both utility and genera tor power occurs Remote Control Features e Remote test switch Simulates normal source failure similar to a transfer switch test push button e Remote transfer to generator Openi
6. ng the contact causes the generator to start and transfer to the generator e Inhibit transfer to generator Opening the contact prevents the transfer switch from transferring to the generator source while connected to the normal source e Remote time delay bypass switch NOTE Requires customer supplied remote normally closed contact and control signaling for each remote feature desired See manu facturer reference drawings and manual for additional details N EMERSON Network Power Communications Option Remote monitoring and control can also be provided through additional network ing software and interface hardware options including web access capability NOTE These enhancements are not included with the standard product Emerson NYSE EMR based in St Louis Missouri USA is a global leader in bringing technology and engineering together to create innovative solutions for customers through its network power process management industrial automation climate technologies and appliance and tools businesses For more information visit Emerson com Emerson Network Power a business of Emerson NYSE EMR is the global leader in enabling Business Critical Continuity from grid to chip for telecommunication networks data centers health care and industrial facilities Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems embedded computing
7. ock out tag out compliance e Main utility breaker rated up to 65kAIC e TVSS modules e Load center e Programmable engine exerciser e ATS position contacts e Voltage monitoring relays 240VAC Isolated ground bar and common ground bus bar Specifications 300 ATS Model AC Cabinet Dimensions H x W x D 68 00 x 25 50 x 6 00 Weight approx 110 Ibs 50 kg Cabinet Enclosure Type NEMA 1 rated Amperage 200 Amp utility standby Voltage 120 240 VAC single phase Safety Compliance UL 67 panel boards EMERSON Network Power 300 ATS Model Elements 1 Utility Main Breaker 7 Programmable rated up to 65kAIC Engine Exerciser 2 Automatic Transfer Switch ATS 8 ATS Position Contacts 3 TVSS Modules 9 240VAC Voltage An teadicenter Monitoring Relays 5 ATS Control 10 Isolated Ground Bar with indication lights 11 Ground Bar i ATS Digital Controller OO Ff O Suppression Module Specifications 300 ATS Model Primary Secondary Nominal Clamp Voltage 232 Vpk 272 Vpk Response Time lt 5ns lt 20ns Peak Pulse Energy up to 800 Joules gt 1920 Joules Peak Pulse Current 8x20us up to 20 kA 200 kA Primary and Secondary Visual Indication LEDs LEDs Remote Indication Hardwired form C dry contacts Hardwired form C dry contacts Safety Compliance UL 1449 recognized UL 1449 recognized Protection Overcurrent amp overvoltage th
8. rcurrent devices Single disconnect 65 kAIC Walking beam discontinued Load Center Disconnect nncs Il Grounding Options Isolated ground Standard ground OlOlSua0lwiniwl xl n 1 Voltage Monitoring Normal Generator Specifications PDC Model AC Cabinet Dimensions 20 00 wide x 65 00 high x 5 75 deep Weight Approx 75 Ibs 50 kg Cabinet Enclosure Type NEMA 1 rated Amperage 200 Amp utility standby Safety Compliance UL 67 Panelboards UL 65k AIC standard slide bar PDC NOTE All PDC cabinets are available with up to 65k AIC ratings Suppression Module Specifications PDC Model Primary Secondary Nominal Clamp Voltage 232 Vpk 272 Vpk Response Time lt 5ns lt 20ns Peak Pulse Energy up to 800 Joules gt 1920 Joules Peak Pulse Current 8x20js up to 20 kA 200 kA Primary and Secondary Visual Indication LEDs Remote Indication Hardwired form C dry contacts Safety Compliance UL 1449 recognized Protection Overcurrent amp overvoltage thermal N EMERSON 3 Network Power 300 ATS Model Standard Features e Automatic Transfer Switch ATS e Double throw electromechanical switching device for inherent isolation of the utility and generator sources e ATS digital controller provides continuous monitoring of both power sources and a start stop signal to the generator e ATS control with indication lights e Key lockable load center door for l
9. s both power distribu tion and TVSS in one seamless unit An Automatic Transfer Switch ATS for gen erator applications is also available The PDC Series provides the lowest possible clamp voltage to peak current performance characteristics available in the market today Integrated V3 SHIELD NTI technology provides peak pulse current handling that surpasses tra ditional fused TVSS devices This series also utlizizes Silicon Avalanche Diode SAD technology providing state of the art protection at the branch service entrance The 30 or 42 position load center enables the PDC series to accommodate a broad range of wiring options The main disconnect allows con venient serviceability and maintenance Generator switching is accommodated with either an Automatic Transfer Switch or Walking Beam Transfer Switch A amp EMERSON Network Power Protection against destructive weather thermal electrical environmental and mechanical forces is vital to assuring the reliability and revenue producing capability of your wireless and wireline networks Ordering Matrix NetXtend PDC Series Service Voltage B 120 240V single phase Primary Suppression SAD 20 kA B MOV200kA TVSS Configuration Kelvin in line Supplemental Suppression MOV 200 kA 0 None Amperage 200 Amp 42 overcurrent devices 300 ATS Series Automatic Transfer Switch Slide bar interlock standard 30 ove