Home

Emerson FTA3100 Brochures and Data Sheets

image

Contents

1. POWER AVAILABLE t ALARM TRANSFER SWITCH NORMAL TRANSFER SWITCH EMERGENCY SYSTEM PRESSURE LOW ELECTRIC ATS TRUE RMS METERING FAIL TO START MOTOR OVERLOAD EMERGENCY ISO SWITCH OFF O PHASE FAILURE PHASE REVERSAL Operator Interface The fire pump controllers feature an opera tor haces with user keypad The interface monitors and displays motor operating condi tions including all alarms events and pressure conditions All alarms events and pressure conditions are displayed with a time and date stamp The display is a 128x64 Backlit LCD ca pable of customized graphics and Cyrillic type character display The display and interface are NEMA rated for Type 2 3R 4 4X and 12 pro tection and is fully accessible without opening the controller door The user interface utilizes multiple levels of password oe for sys tem security A minimum of 3 password levels are provided Approvals Firetrol fire pump controllers are listed by Un derwriters Laboratories Inc in accordance with UL218 Standard for Fire Pump Controllers CSA Standard for Industrial Control Equipment They are built to meet or exceed the require ments of the approving authorities as well as NEMA the latest editions of NFPA 20 Installa tion of Centrifugal Fire Pumps NFPA 70 National Electrical Code and are approved by Factory Mutual APPROVED Digital Status Alarm Messages The digital display indicates text messages fo
2. Variable Speed Electric Fire Pump Controllers SF Firetrol EMERSON Network Power Side by side disconnect circuit breaker provides single handle sequencing ELET Controls the speed of a centrifugal pump to limit the system pressure in a fire sprinkler system Firetrol variable speed electric fire pump controllers provide a variable frequency drive VFD in a PID process control loop to control the speed of a centrifugal pump for the purpose of limiting the system pressure in a fire sprinkler system The Mark IIxc monitors the VFD and if a problem is detected switches the controller to bypass mode The controllers are available in the following configurations FTA3100 VFD with Across The Line Bypass FTA3110 VFD with Autotransformer Bypass FTA3130 VFD with Digital Soft Start Bypass The controllers include pilot lights for indica tion of Drive Ready and Bypass Active and also a selector switch for manual bypass operation These Controllers are available assembled with power transfer switches for use with an emergency generator set or second utility power source aaa SYSTEM PRESSURE LOW ELECTRIC Pum runnin TRUE RMS METERING ne uceoeen REMOTE START INTERLOCK ON rmrosraar MOTOR OVERLOAD ee PHASE FAILURE PHASE REVERSAL i OES automanc SHUTDOWN DISABLED OVERVOLTAGE J 1 L UNDERVOLTAGE SYSTEM STATUS i
3. e panel featuring a 128 x 64 pixel backlit LCD Graphical Display Membrane Type User Control Push buttons and easy to read LED Indica tors for e POWER AVAILABLE e ALARM e TRANSFER SWITCH NORMAL If unit ordered with Automatic Power Transfer awe e TRANSFER SWITCH EMERGENCY If unit ordered with Automatic Power Transfer Switch e SYSTEM PRESSURE LOW e PUMP RUNNING e DELUGE OPEN e REMOTE START e INTERLOCK ON e FAIL TO START e MOTOR OVERLOAD EMERGENCY ISO SWITCH OFF If unit ordered with Automatic Power Transfer Switch e PHASE FAILURE e PHASE REVERSAL e AUTOMATIC SHUTDOWN DISABLED e OVERVOLTAGE e UNDERVOLTAGE Digital Pressure Display USB Host Controller and Port Solid State Pressure Transducer Data Log Event Log 3000 Events True RMS Metering with simultaneous 3 Phase Display of Amps Volts Frequency Pressure and Alarm Messages Disk Error message Disk Near Full message Pressure Error message Motor Over 320 message Local Start message Remote Start message Emergency Start message Fail To Start message Undervoltage message Overvoltage message NEMA Type 12 IEC IP54 enclosure Suitable for use as Service Equipment Each standard controller comes with user configurable options for e Interlock Alarm Low Pressure Audible e Low Suction ee Run e User Defined Input Weekly Test Data Logging The user interface monitors the system and logs the following data e Motor Calls S
4. r the stats and alarm conditions ot e Motor On e Sequential Start Time e Minimum Run Time Local Start Off Delay Time e Remote Start e Fail to Start e System Battery Low e Under Voltage e Over Voltage e Locked Rotor Trip Over Frequency e Emergency Start Motor Over 320 e Drive Not Installed Motor Overload e Disk Error e Disk Near Full e Pressure Error The Sequential Start Timer and Minimum Run Timer Off Delay Times are displayed as numeric values reflecting the value of the remaining time LED Visual Indicators LED indicators visible with the door closed indicate Power Available Alarm Pump Running System Pressure Low Remote Start e Transfer Switch Normal Deluge Open Transfer Switch Emergency Phase Failure e Phase Reversal Interlock On e Fail To Start Motor Overload Emerg Iso Switch Off Automatic Shutdown Disabled Overvoltage e Undervoltage Standard features include Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Single handle Isolating Disconnect Switch Circuit Breaker mechanism Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condi tion Built in Start and Stop push buttons to bypass auto matic start circuits Minimum Run Timer Off Delay Timer Daylight Savings Time Option Weekly Test Timer Elapsed Time Meter Door mounted display interfac
5. rters 1050 Dearborn Drive Columbus OH 43085 Tel 1 614 888 0246 EmersonNetworkPower com Firetrol com While every precaution has been taken to ensure accuracy and completeness herein ASCO assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions Information and specifications are subject to change without notice Emerson Consider It Solved Emerson Network Power the Emerson Network Power Logo ASCO Firetrol and the Firetrol Logo are trademarks or registered trademarks of Emerson Electric Co All other names and logos referred to are trade names trademarks or registered trademarks of their respective owners 2013 Emerson Electric Co CB3100 50 D EMERSON CONSIDER IT SOLVED
6. tarts Pump Total Run Time e Pump Last Run Time e Total Controller Pwr On Time e Last Pump Start Min Max System Pressure e Last Phase Fail Reversal Last Locked Rotor Trip e Last Locked Rotor Current Min Max Frequency e Max Starting Currents Max Run Currents USB Host Controller The controller is equipped with a built in USB Host Controller A USB port capable of accept ing a USB Flash Memory Disk is provided The controller saves all operational and alarm events to the flash memory on a daily basis Each saved event is time and date stamped The total amount of historical data saved depends on the size of the flash disk utilized The operator can save settings and values to the flash disk on e Min Max Voltage per Phase while idle not demand via the user interface running e Min Voltage per Phase during Start e Min Max Voltage per Phase during Run USB Host Port Event Recording and Flash Disk Memory The controller records all opera tional and alarm events to system memory All events are time and date stamped and include an index number The system memory has the capability of storing 3000 events and allows the user access to the event log via the user in terface The user can scroll through the stored messages in groups of 1 or 10 ASCO Power Technologies Firetrol Brand Products 111 Corning Road Suite 120 Cary NC 27518 Tel 1 919 460 5200 Fax 1 919 460 5250 Emerson Network Power Global Headqua