Home
Emerson FTA1000 Brochures and Data Sheets
Contents
1. Electric Fire Pump Controllers Ss Firetrol EMERSON Network Power Side by side disconnect circuit breaker provides single handle sequencing en f I 3 Combined automatic and manual fire pump controllers for starting electric motor driven fire pumps Firetrol combined automatic and manual fire pump controllers are intended for starting elec tric motor driven fire pumps and are available in the following configurations FTA1000 Full Voltage Starting FTA1250 Part Winding Reduced Current Starting Closed Circuit Transition FTA1300 Wye Delta Reduced Voltage Start ing Open Circuit Transition FTA1350 Wye Delta Reduced Voltage Start ing Closed Circuit Transition FTA1500 Primary Resistance Reduced Volt age Starting Closed Circuit Transi tion FTA1800 Autotranstormer Reduced Voltage Starting Closed Circuit Transition FTA1930 Digital Solid State Reduced Voltage Starting Closed Circuit Transition These Controllers are available assembled with power transfer switches for use with an emergency generator set or second power source ete hd cere CaS ore iat SYSTEM STATUS i m POWER AVAILABLE DB ALARM SYSTEMPRESSURE Low ELECTRIC Pump Runna TRUE RMS METERING DELUGE OPEN REMOTE START INTERLOCK OM ID FAL TO START PHASE FAILURE PHASE REVERSAL a AUTOMATIC SHUTDOWN DISABLED Ne OVERVOLTAGE J i UNDERV
2. OLTAGE IE MOTOR OVERLOAD SYSTEM STATUS POWER AVAILABLE ALARM TRANSFER SWITCH NORMAL TRANSFER SWITCH EMERGENCY SYSTEM PRESSURE LOW ELECTRIC ATS PUMP RUNNING TRUE RMS METERING FAIL TO START MOTOR OVERLOAD EMERGENCY ISO SWITCH OFF O PHASE PAILURE O PHASE REVERSAL Operator Interface The fire pump controllers feature an opera tor Mn meat with user keypad The interface monitors and displays motor operating condi tions including all alarms events and pressure conditions All alarms events and pressure conditions are displayed with a time and date stamp The display is a 128x64 Backlit LCD ca pable of customized graphics and cryllic type character display The display and interface are NEMA rated for Type 2 3R 4 4X and 12 pro tection and is fully accessible without opening the controller door The user interface utilizes multiple levels of password e for sys tem security A minimum of 3 password levels are provided Approvals Firetrol fire pump controllers are listed by Un derwriters Laboratories Inc in accordance with UL218 Standard for Fire Pump Controllers CSA Standard for Industrial Control Equipment and approved by Factory Mutual They are built to meet or exceed the requirements of the ap proving authorities as well as NEMA and the latest editions of NFPA 20 Installation of Centrifugal Fire Pumps and NFPA 70 National Electric
3. al Code c UL us APPROVED Digital Status Alarm Messages The digital display indicates text messages for the stats and alarm conditions ot e Motor On e Sequential Start Time e Minimum Run Time Local Start Off Delay Time e Remote Start e Fail to Start e System Battery Low e Under Voltage e Over Voltage e Locked Rotor Trip Over Frequency e Emergency Start Motor Over 320 e Drive Not Installed Motor Overload e Disk Error e Printer Error e Disk Near Full e Pressure Error The Sequential Start Timer and Minimum Run Timer Off Delay Times are displayed as numeric values reflecting the value of the remaining time LED Visual Indicators LED indicators visible with the door closed indicate Motor Overload e Emerg Iso Switch Off Automatic Shutdown Disabled Overvoltage e Undervoltage e Power Available Alarm e Pump Running System Pressure Low e Remote Start e Transfer Switch Normal e Deluge Open Transfer Switch Emergency e Phase Failure e Phase Reversal e Interlock On e Fail To Start Standard features include Voltage surge protector Main Disconnect Switch sized for connected motor horsepower and voltage Fire pump Circuit Breaker Single handle Isolating Disconnect Switch Circuit Breaker mechanism Motor contactor Emergency Manual Run Mechanism to mechanically close motor contactor contacts in an emergency condi tion Built in Start and Stop push buttons to bypass auto matic start c
4. ircuits Minimum Run Timer Off Delay Timer Daylight Savings Time Option Weekly Test Timer Elapsed Time Meter Door mounted display interface panel featuring a 128 x 64 pixel backlit LCD Graphical Display Membrane Type User Control Push buttons and easy to read LED Indica tors for e POWER AVAILABLE e ALARM e TRANSFER SWITCH NORMAL If unit ordered with Automatic Power Transfer Slat e TRANSFER SWITCH EMERGENCY If unit ordered with Automatic Power Transfer Switch e SYSTEM PRESSURE LOW e PUMP RUNNING e DELUGE OPEN e REMOTE START e INTERLOCK ON FAIL TO START e MOTOR OVERLOAD EMERGENCY ISO SWITCH OFF If unit ordered with Automatic Power Transfer Switch e PHASE FAILURE e PHASE REVERSAL e AUTOMATIC SHUTDOWN DISABLED e OVERVOLTAGE e UNDERVOLTAGE Digital Pressure Display USB Host Controller and Port Solid State Pressure Transducer Data Log Event Log 3000 Events True RMS Metering with simultaneous 3 Phase Display of Amps Volts Frequency Pressure and Alarm Messages Disk Error message Disk Near Full message Pressure Error message Motor Over 320 message Local Start message Remote Start message Emergency Start message Fail To Start message Undervoltage message Overvoltage message NEMA Type 2 enclosure Suitable for use as Service Equipment Each standard controller comes with user configurable options for e Interlock Alarm Low Pressure Audible e Low Suction anp Run Use
5. r Defined Input Weekly Test Data Logging The user interface monitors the system and logs the following data e Motor Calls Starts Pump Total Run Time e Pump Last Run Time e Total Controller Pwr On Time e Last Pump Start Min Max System Pressure e Last Phase Fail Reversal Last Locked Rotor Trip USB Host Controller The controller is equipped with a built in USB Host Controller A USB port capable of accept ing a USB Flash Memory Disk is provided The controller saves all operational and alarm events to the flash memory on a daily basis Each saved event is time and date stamped The total amount of historical data saved depends on the size of the flash disk utilized The operator can save settings and values to the flash disk on demand via the user interface e Last Locked Rotor Current Min Max Frequency e Max Starting Currents Max Run Currents e Min Max Voltage per Phase while idle not running e Min Voltage per Phase during Start e Min Max Voltage per Phase during Run USB Host Port Event Recording and Fach Diek Memory The controller records all opera tional and alarm events to system memory All events are time and date stamped and include an index number The system memory has the capability of storing 3000 events and allows the user access to the event log via the user in terface The user can scroll through the stored messages in groups of 1 or 10 ASCO Power Technologies Firetrol Brand P
6. roducts 111 Corning Road Suite 120 Cary NC 27518 Tel 1 919 460 5200 Fax 1 919 460 5250 Emerson Network Power Global Headquarters 1050 Dearborn Drive Columbus OH 43085 Tel 1 614 888 0246 EmersonNetworkPower com Firetrol com While every precaution has been taken to ensure accuracy and completeness herein ASCO assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions Information and specifications are subject to change without notice Emerson Consider It Solved Emerson Network Power the Emerson Network Power Logo ASCO Firetrol and the Firetrol Logo are trademarks or registered trademarks of Emerson Electric Co All other names and logos referred to are trade names trademarks or registered trademarks of their respective owners 2013 Emerson Electric Co CB1000 50 B EMERSON CONSIDER IT SOLVED
Download Pdf Manuals
Related Search
Related Contents
Téléchargez les textes des invités. Sony NP-F950/B User's Manual Le divertissement dans toutes les pièces. - ROTRONIC お願い はじめに 各部の名称 STA945-3 Copyright © All rights reserved.
Failed to retrieve file