Home

Emerson F468 User's Manual

image

Contents

1. 4 Installation is complete Turn electricity FAN SWITCH a on at the main fuse or circuit breaker CHAIN J WHITE WIRE box Blue Wine RK 9 WIRE ogg NOTE It is advisable to periodically BLACK WIRE WHITE WIRE check the tightness of the shade 4 CENTER 7 HEX NUT retainers Fan operation may cause SCREW gt them to loosen 2 SCREWS 8 LOCKWASHER 6 LIGHT FITTER SWITCH HOUSING FAN SWITCH Figure 4 9 Proceed to Installation of Glass Shades section Installation of Glass Shades 60 WATT MAX CHAIN PULL INTERMEDIATE 1 Remove shade retainer from socket ell BASE BULB 3 Seat shade in shade holder and screw shade retainer onto socket Repeat for SHADE HOLDER other two shades 2 Install a 60 watt maximum intermediate SRDE base light bulb into each socket SOCKET To avoid fire hazard do not exceed wattage indicated on the fixture GLASS SHADE Figure 5 SS stave RETAINER 3 Install chain pull onto the light switch chain For repair parts phone 1 800 654 3545 EMERSON Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No BP7254 2 Form No F40BP72540002 Printed in China 09 06 READ AND SAVE THESE INSTRUCTIONS THIS OWNER S MANUAL COVERS EMERSON LIGHT KITS USE THESE FIXTURES ONLY WITH EMERSON CF AND F SERIES CEILING FANS NOTE ANY LIGHT KIT O
2. EVER IT INSTALLS IN A SIMILAR MANNER gt A 0 5 To avoid possible fire or electrical shock make certain no bare wire strands are exposed outside wire connectors Figure 3 9 Carefully tuck all wires and splices into the switch cup 1 Figure 2 10 Connect the motor connector 4 to the switch cup connector 5 11 Position the cup light fitter 1 7 on the cover plate 2 and install the three screws 3 that were previously removed in step 2 and tighten securely 12 Proceed to Installation of Glass Shades section Installation on Emerson Fans Having Two Piece Die Cast Switch Housings 1 Remove all parts and parts packages from carton 2 Remove the cover 5 from the switch housing 1 by removing the two outer screws 2 See Figure 4 3 Remove the center screw 4 from the cover 5 Insert the black and white wires from the light kit fitter 6 through the hole and thread the switch housing cover tightly onto the light kit fitter 4 Insert the black and white wires through the lockwasher 8 and hex nut 7 supplied Firmly tighten the hex nut to secure the light kit fitter to the switch housing cover 5 5 Carefully locate the white and blue wires labeled either L or LIGHT in the switch housing and remove the wire connectors 3 from the wires 6 Connect the white wire from the ceiling fan to the white wire of the light fitter 6 Connect the blue wire from
3. LABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Form No F40BP72540002 Part No BP7254 2 U L Model No LK37 LK800 LK801 LK803 F468 Safety Instructions To avoid fire shock and serious personal injury follow all instructions carefully 1 2 Read your Owner s Manual carefully before installing the light fixture Retain Owner s Manual for future reference Be careful of the fan and blades when cleaning painting or working near the fan Before installing or servicing the light fixture or ceiling fan switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Do not exceed the wattage indicat
4. R FITTER AND GLASS COMBINATION COVERED BY THIS MANUAL WEIGHS 5 8 LBS OR LESS amp Ceiling Fan Light Fixture EMERSON Owner s Manual LIMITED WARRANTY What The Warranty Covers All products covered by this Owner s Manual are warranted against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is All components are covered by this warranty for one year from the date you purchased your light fixture ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Electric Co Do To Correct Problems Emerson Electric Co will replace a defective Emerson Light Fixture at no charge to you WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE LIGHT FIXTURE TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Electric Co 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the produc
5. ed on fixture ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring Make certain no bare wires are exposed outside the wire connectors All wiring must conform to national and local electrical codes Follow the recommended instructions for the proper method of wiring your new light fixture If you feel you do not have enough electrical wiring knowledge or experience have your light fixture installed by a licensed electrician Any electrical work not described in this manual should be performed by a licensed electrician WARNING To reduce the risk of possible fire and electrical shock install only on Emerson CF and F Series Ceiling Fans This light kit is not to be used with CF652 CF653 CF670 CF680 CF742 and CF2000 Series Ceiling Fans installed in damp or wet locations Assembly and Installation Do not install or use the light fixture if any part is missing or damaged Call toll free 1 800 654 3545 To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring Installation on Emerson Fans Having Modular Switch Cup with Center Screw 1 Remove all parts and parts packages from the carton 2 Remove the switch cup 1 from the cover plate 2 by removing the three screws 3 around the side of the switch cup Figu
6. re 1 3 Disconnect the motor connector 4 from the switch cup connector 5 Figure 1 4 Remove the center screw 6 from the switch cup Figure 1 5 Carefully locate the white and blue wires labeled either L or LIGHT in the switch cup and remove the wire connectors from the wires 6 Insert the black and white wires from the light fitter 7 through the center hole in the switch cup Figure 2 and thread the switch cup onto the light fitter Hold wires taut while installing switch cup to prevent the wires from twisting 2 COVER PLATE 5 SWITCH CUP CONNECTOR FAN SWITCH 1 SWITCH CHAIN CUP 6 CENTER SCREW ai amp Figure 1 7 Insert the black and white wires through the lockwasher 8 and hex nut 9 supplied Firmly tighten the hex nut to secure the light fitter to the switch cup 8 Connect the white wire from the switch cup to the white wire of the light fitter Figure 2 Connect the blue wire from the switch cup to the black wire of the light fitter Use listed wire connectors previously removed in step 5 to make connections Figures 2 and 3 4 MOTOR lt 2 COVER PLATE wore 5 SWITCH CUP CONNECTOR 6 WIRE CONNECTORS BLUE WIRE BLACK WRE 7 WHITE WIRES FAN SWITCH CHAIN 8 LOCKWASHER 7 LIGHT FITTER NOTE YOUR FITTER MAY NOT LOOK THE SAME AS THE ONE IN THIS ILLUSTRATION Figure 2 HOW
7. t with your request e To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Light Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Electric Co e Use of parts or accessories not authorized by Emerson Electric Co e Mishandling improper installation modifications or damage to your light fixture while in your possession or e Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when The original purchaser or user ceases to own the product or e The ceiling fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAI
8. the ceiling fan to the black wire of the light fitter Use listed wire connectors previously removed in step 3 to make connections Figures 3 and 4 7 Carefully tuck all wires and splices into the switch housing 1 8 Attach the cover light fitter 5 6 to the switch assembly housing 1 using the two screws 2 that were removed in Step 2 Figure 4 A WARNING To avoid possible fire or electric shock be careful not to pinch wires between switch housing and light fitter