Home

Emerson CF704SAW02 Owner's Manual

image

Contents

1. 6 HEAD SCREWS 3 A WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades BLADE FLANGE FAN BLADE Figure 7 NOTE Take care not to scratch the fan housing when installing the blade assemblies 1 4 20 x 1 2 SCREW A Figure 8 4 You have now completed the assembly of your new ceiling fan Using Your Ceiling Fan A WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device 1 Restore electrical power to the electrical box by turning the electricity on at the main fuse box or circuit breaker panel 2 Check the operation of the fan by gently pulling on the pull chain switch _ 3 All fans are shipped from the factory with the re versing switch positioned to circulate air downward If airflow is desired in opposite direction turn your fan off and wait for the blades to stop turning then slide the reversing switch to opposite position and turn fan on again The fan blades will turn in the opposite direction and reverse the airflow Your fan model is equipped with a 4 position 3 speed pull chain switch The operating sequence is as follows T REVERSING SPEED CONTROL SWITCH SWITCH THREE SPEED 1st Pull High 2nd Pull Medium 3rd Pull
2. Low 4th Pull OFF Maintenance IMPORTANT CARE INSTRUCTIONS For Your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish A WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock Accessories 1 Ceiling Fan Light Kits see store or catalog 2 Emerson SW 95 Speed Control see store or catalog WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage WARNING FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN Trouble Shooting TROUBLE 1 Fan will not start 2 Fan sounds noisy 3 Fan wobbles or s
3. Model No No Description CF705SWW02 CF705SPB02 CF705SAB02 CF705SW02 CF705SAW02 CF704SWWO2 CF704SPB02 CF704SAB02 CF704SW02 CF704SAW02 Switch Housing Assembly 761533 2 761533 1 761533 761533 4 761533 7 760384 760384 1 760384 2 760384 3 760384 4 Flange Assembly set of 5 761554 761554 1 761554 2 761554 3 761554 6 761535 761535 1 761535 2 761535 3 761535 4 Blade Assembly set of 5 761548 761548 1 761548 1 761548 2 761548 7 761542 761542 1 761542 1 761542 2 761542 3 Loose Parts Bag 761555 2 761555 761555 1 761555 761555 761555 2 761555 761555 1 761555 761555 Containing Blade Hardware Hanging Hardware Wood Pendant Coupling 5 Harness Wiring 761543 761543 761543 761543 761543 761529 761529 761529 761529 761529 Owners Manual BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 BP7080 6 4 HARDWARE BAG NOT SHOWN Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION e PART NUMBER e PART DESCRIPTION e NAME OF ITEM e MODEL NUMBER For repair parts phone 1 800 654 3545 EMERSON Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Printed in Taiwan Part No F40BP70800006 11 00 Form No BP7080 6
4. use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when e The original purchaser or user ceases to own the product or e The fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Company REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Repair Parts List Key Model No Model No Model No Model No Model No Model No Model No Model No Model No
5. you are responsible for all costs or removal reinstallation and shipping of the product to Emerson Company How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Company 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request e To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Company e Use of parts or accessories not authorized by Emerson Company e Mishandling improper installation modifications or damage to your ceiling fan while in your possession or e Unreasonable
6. READ AND SAVE THESE INSTRUCTIONS Model No CF705SABO2 CF 04SABO2 CF705SPBO2 CF 04SPBO2 ee CF705SWWO2 CF704SWWO2 The date code of tis fn CF7Q5SWO2 CF704SWO2 may be found on the box ao CFZO5SAWO2 CF704SAWO2 You should record this data above and keep it in a safe see ue ives Net Weight 14 0 Lbs Net Weight 11 0 Lbs by Northwind TRADITIONAL SNUGGER Ceiling Fan Owner s Manual Part No F40BP70800006 Form No BP7080 6 A WARNING WARNING To avoid fire shock and serious personal injury follow these instructions Safety Instructions Read your owner s manual carefully and keep it for future reference Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing Do not put anything into the fan blades while they are turning Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring must sat
7. and may need to be replaced Consult a qualified electrician if in doubt 1 Securely attach the mounting plate to the outlet box Figure 2 using two screws supplied with outlet box Pull the black white and ground wires out of the outlet box through the hole in the mounting plate and lay them to the side as shown in Figure 3 NOTE For better fan performance make sure the mounting plate is level Additional washers not included may be needed to insert between the electrical box and mounting plate Figure 2 MOUNTING PLATE LEVELING WASHER IF REQUIRED NGUNTINeScaENS SUPPLIED WITH PLAIN WASHER OUTLET BOX SUPPLIED Figure 2 2 Slide the three rubber washers over the three threaded studs on the bottom surface of the mounting plate 3 Carefully lift the fan motor assembly and engage the slot in the motor bracket with the hook on the mounting plate so that it is securely suspended Figure 3 Then connect wiring to your fan according to section HOW TO WIRE YOUR CEILING FAN MOUNTING PLATE RUBBER WASHER THREADED STUDS SUPPLY WIRE LEADS MOTOR MOTOR BRACKET Figure 3 4 Once wiring is completed lift the motor bracket so that the four threaded studs on the mounting plate protrude through the four slots in the motor bracket See Figure 4 Securely tighten the four 3 16 locknuts supplied onto the threaded studs then try to shake the motor bracket to ensur
8. e that the assembly is tight Proceed to section HOW TO PUT YOUR CEILING FAN TOGETHER OUTLET BOX MOUNTING y i NU oA PLATE A A SUPPLIED l MOTOR BRACKET FAN MOTOR SWITCH HOUSING Figure 4 How To Wire Your Ceiling Fan If you feel that you do not have enough electrical NOTE If you are using an Emerson Light Fixture wiring knowledge or experience have your fan with your fan see the Light Fixture Owner s installed by a licensed electrician Manual for wiring 2 Connect the fan motor white wire to the supply A WARNING white neutral wire using a listed wire connector To avoid possible electrical shock be sure electricity Figure 5 is turned off at the main fuse box before wiring C 3 Connect the fan motor black wire and blue wire to NOTE If you are not sure if the outlet box is the supply black hot wire using a listed wire grounded contact a licensed electrician for advice connector Figure 5 Your fan is now wired to be as it must be grounded for safe operation turned on and off from the fan switch After i connections have been made turn leads upward 1 Connect the green grounding wires from the motor and carefully push leads into the outlet box with bracket and the mounting plate to the grounding the white and green leads on one side of the outlet conductor of supply this may be a bare wire or wire box and the black and blue leads on the other side with green colored insulation of the outlet bo
9. hakes PROBABLE CAUSE Reversing switch in neutral position Fuse or circuit breaker blown Loose power line connections to the fan or loose switch wire connections in switch housing Blades not attached to fan Loose screws in motor housing Screws securing fan blade flanges to motor are loose Wire connectors inside switch housing rattling Screws holding flanges to blades are loose Screws securing fan blade flanges to motor are loose Fan blade flanges not seated properly SUGGESTED REMEDY Make sure reversing switch position is all the way to one side Check main and branch circuit fuses or circuit breakers Check line wire connections to fan and switch wire connections in the switch housing Attach blades to fan before operating Check to make sure all screws in motor housing are snug not over tight Check to make sure the screws which attach the fan blade flanges to the motor are tight Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing Tighten securely Check to be sure screws which attach the fan blade flanges to the motor are tight Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on Ho
10. isfy National and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 5 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage WARNING To Reduce the risk of pers
11. onal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly Installed Wire Length Wire Size A W G One Phillips head screwdriver Up to 50 ft 14 One 1 4 blade screwdriver 50 100 ft 12 One stepladder One wire stripper Three wire connectors supplied 4 WARNING Materials Before assembling your ceiling fan refer to section on proper method of wiring your fan page 5 If you Wiring electrical box and box connectors must be of feel you do not have enough wiring knowledge or type required by local code The minimum wire would experience have your fan installed by a licensed be a 3 conductor 2 wire with ground of size shown at electrician right Unpacking Instructions For your convenience check off boxes are provide next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bag in Aa WARNING a small container to keep them from being lost If Do not install or use fan if any part is damaged or any parts are missing contact your local retailer missing Call Toll Free or catalog
12. outlet for replacement before 1 800 654 3545 ee 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper 4 WARNING foam pad with the lead wires up This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage FAN BLADES UPPER 1 Check to see that you have received the following FOAM PAD parts NOTE If you are uncertain of part description i refer to exploded view illustration a Fan housing b Mounting plate c Fan motor assembly P d Five fan blades y MOTOR e Five blade flanges ESLT f One loose parts bag containing 1 Fifteen 3 16 24 x 9 32 phillips washer head screws 2 One wood pendant 3 One coupling 4 Three wire connectors 5 Four 3 16 24 x 3 8 housing screws 6 Four 3 16 hex locknuts 7 Ten 1 4 20 x 1 2 phillips head screws Electrical Requirements Your new ceiling fan will require a grounded electrical 4 WARNING supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and Turning off wall switch is not sufficient To avoid capable of withstanding a load of at least 50 pounds possible electrical shock be sure electricity is turned off at the main fuse bo
13. w to Put Your Ceiling Fan Together Tighten the mounting plate screws to the outlet box and or secure outlet box Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation Mounting plate and or ceiling outlet box is not securely fastened Fan blades out of balance LIMITED WARRANTY What The Warranty Covers This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is As it applies to the motor this warranty will last for twenty years from the date you purchased your ceiling fan All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Company Do To Correct Problems Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor blade component or other accessory at no charge to you If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided Emerson Company will refund the actual purchase price of your fan We will ship the repaired product or replacement to you at no charge but
14. x To avoid risk of fire or shock check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for BLACK FAN WIRE SUPPLY GROUNDING A WARNING _ CONDUCTOR WIRE WHITE SUPPLY NEUTRAL the ground wire Do not operate fan until blades are in place Noise and fan damage could result E E WIR CONNECTORS BLUE FAN WIRE 4 Cut the 3 speed switch pull chain to a desired length optional Connect the wood pendant supplied to the 3 speed switch pull chain by sliding the wooden pendant small hole first onto the pull chain Attach the chain coupler to the end of the chain and allow the wooden pendant to fall GREEN GROUND WIRE WHITE FAN WIRE Figure 5 down over the coupling _ 5 Return to step 4 of section HOW TO HANG YOUR CEILING FAN How To Put Your Ceiling Fan Together 1 Align the four holes in the fan housing with the four 2 Mount the blade flanges to the fan blades using holes in the mounting plate and install four three 3 16 24 x 9 32 washer head screws per 3 16 24 x 3 8 screws supplied Figure 6 blade supplied Figure 7 Repeat for four remaining blades a cieener 3 Attach one blade assembly to the motor using two N 1 4 20 x 1 2 phillips head screws supplied Figure 8 Make sure the screws are tightened securely Repeat this procedure for the other four blade assemblies N 3 16 24 x 9 32 WASHER Figure
15. x before wiring All wiring must be in accordance with National and Local Codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock A WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING To avoid fire or shock follow all wiring instructions carefully If your fan is to replace an existing ceiling light fixture Any electrical work not described in these instructions should be done or approved by a turn electricity off at the main fuse box at this time and a licensed electrician remove the existing light fixture How to Hang Your Ceiling Fan WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 1 G CEILING AT LEAST 7 Z FLOOR a Figure 1 A WARNING The outlet box must be securely anchored and capable of withstanding a load of at least 50 Ibs WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support

Download Pdf Manuals