Home

Emerson 10 kVA Brochure

image

Contents

1. Business Critical Continuity Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co 2008 Emerson Electric Co
2. 6 kVA An optional hardwire version that includes a maintenance bypass switch is also available When the ease of plug and play power connections is desired optional versions of the power distribution box convert the Liebert GXT2 6 kVA to a cord type input with receptacles for output distribution as well as maintenance bypass capability User replaceable hot swappable internal batteries front with panel removed Easily converts to tower configuration with supplied hardware Other Product Features Of The New Liebert GXT2 6 kVA Include Flexibility u Rack tower configuration A single part number installs in either configuration u Automatic frequency detection The Liebert GXT2 6 kVA detects and matches line input frequencies of either 60 or 50 Hz 2 Additional runtime with 2U battery cabinets UPS cabinet includes rear panel plug and play connections for optional additional battery cabinets 2 IntelliSlot communications port Utilizes Liebert IntelliSlot Web Card to provide SNMP and web based monitoring and control your UPS u includes Windows based configuration program Allows various operating parameters to be adjusted and tests to be scheduled a Built in serial communications for use with Liebert MultiLink Automated Shutdown Software Allows you to monitor communication between the UPS and a server and ensures a graceful unattended shutdown a Built in closure signals P
3. 60 Hz L L G 220 230 or 240 L L G Note Contact your Liebert representative or www liebert com for more details TY Description Paralleling POD maximum 3 GXT2 10000RT208 connection for 20kVA capacity plus 10kVA redundancy requires 1 paralleling cable p n 2 20 6 for connection to each GXT2 10000RT208 GXT2 4500RT230 GXT2 10000R230 4500 3150 10000 7000 10000 7000 10000 7000 Ratina 20 000VA 16 000W at 120 208 or 120 240 Unit Dimensions 16 94 w x 9 85 d x 16 61 h 430mm w x 250mm d x 422mm h Shipping Dimensions 23 05 wx16 74 d x 19 38 h 585mm w x 425mm d x 492mm h 41 891 19kq 48 941 22 2kq Unit Weight Shipping Weight Description Paralleling cable approximately 6 feet lona ION GXT2 10000RT208 GXT2 288RTBKIT GXT2 PP20KRT208 GXT2 20KPC 6 PD 201 20kVA 10kVA Required Paralleling Components Ensuring The High Availability Of Mission Critical Data And Applications Emerson Network Power the global leader in enabling business critical continuity Liebert Corporation ensures network resiliency and adaptability through a family of technologies cA nie als including Liebert power and cooling technologies that protect and support 800 877 9222 Phone U S 8 business critical systems Liebert solutions employ an adaptive architecture that Canada Only aaa 614 888 0246 Phone Outside U
4. 78 1 35 5 two required Type Valve regulated non spillable flame retardant lead acid Quantity x V x Rating 12x 12V x 9 0 AH one required 12 x 12V x 9 0 AH two required Battery Mfq Part 4 Yuasa REW 45 12 FR Recharge Time 6 Hours to 90 capacity after full discharge into 100 load OPTIONAL EXTENDED BATTERY CABINET Model Number GXT2 144VBATT GXT2 288RTVBATT requires two GXT2 288RTBKIT DIMENSIONS W x D x H in mm 3 5 X 24 2 x 16 9 87 x618 x 430 7 0x 26 0 x 16 9 178 x 660 x 430 WEIGHT Ibs kg Unit 93 6 42 5 197 8 89 9 Total weight with batteries BATTERY PARAMETERS Type Valve regulated non spillable flame retardant lead acid Oty x V x Rating 12x 12V x 9 0 AH per kit 12x 12V x 9 0 AH per kit two required Battery Mfg Part Yuasa REW 45 12 FR ENVIRONMENTAL Operating Tem 32 F to 104 F 0 C to 40 C Storage Tem 5 F to 122 F 15 C to 50 C Relative Humidit 0 to 95 non condensin Operating Elevation Up to 10 000 ft 3000m at 104 F 40 C without deratin Storage Elevation 50 000 ft 15 000m maximum AGENCY Safet UL 1778 cUL Listed Suitable for computer room applications RFI EMI FCC Part 15 Subpart B Class A Transportation ISTA Procedure 1A Note Part Numbers GXT2 6000RT208 and GXT2 10000RT208 do not include internal battery kits When calculating total unit weight add weight of internal batteries GXT2 6000RT208 Model Number Amp Ratina Input Power Connection Output Power Conn
5. designed for use with the new generation of high power switches this compact UPS packs 10 kVA 8 kW of power into a 6U rack tower package with flexible output voltage and optional output distribution The UPS includes built in user replaceable batteries for up to five minutes of runtime at full load Rear view showing built in maintenance bypass switch Controls and indicators Liebert GXT2 10kVA 208V Rack configuration Front view bezels removed Liebert GXT2 10kVA 208V showing battery and power module Tower Configuration The new cabinet allows the on line 10 kVA UPS to be installed in a rack for increased flexibility and functionality The UPS has a dual inverter design capable of providing simultaneous output voltages of 240 120 208 120 230 115 220 110 or 200 100 The new 6U cabinet is the smallest for 208 120 selectable voltage in the 10 kVA size The unit features integrated internal manual and automatic maintenance bypass swappable power module battery modules auto detection of extended battery cabinets and optional plug and play distribution plates Other Product Features Of The Liebert GXT2 10 kVA Include u Rack tower configuration A single part number installs in either configuration u Automatic frequency detection The Liebert GXT2 10 kVA detects and matches line input frequencies of either 60 or 50 Hz 2 Additional runtime with 4U battery cabinets UPS cabinet includes rear pa
6. requires that input conductors of the UPS including neutral be disconnected from the input source when the UPS is in battery mode The Liebert GXT2 6 kVA features a patented circuit that maintains the UPS output neutral to ground bond in all modes of operation thereby eliminating any voltage induced on the UPS output neutral connection PD HDWR Input hardwire Output hardwire PD 002 Includes bypass Input L14 30 Output 2 5 15 20 2 L6 20 PD 005 Includes bypass Input L14 30 Output 4 L5 20 2 L5 30 6 kVA Power Output Distribution Options A standard removable power distribution box provides flexibility when installing the UPS Optional power distribution boxes are available with a built in maintenance bypass switch that allows hot swapping of the entire UPS PD HDWR MBS Includes bypass Input hardwire Output hardwire PD 003 Includes bypass Input L14 30 Output 4 5 15 20 2 16 30 PD 006 Includes bypass Input L14 30 Output 4 L5 20 2 L6 30 PD 001 Includes bypass Input L14 30 Output 4 5 15 20 1 L6 30 1 L14 30 PD 004 Includes bypass Input L14 30 Output 4 C19 PD 007 Includes bypass Input L14 30 Output 4 L6 20R 6 kVA 230V Liebert Brings You 10 kVA Of Power In Just 6U Of Space This Liebert GXT2 10 kVA unit is a flexible solution for protecting rack mount equipment including VolP and PoE Especially
7. 101 Output 8 5 20R T type 2 L6 30R PD 102 Output 4 5 20R T type 4 L6 30R PD 103 Output 4 5 20R T type 4 L6 30R PD 104 Output 4 5 20R T type 2 L6 30R 2 L6 20R PD 105 Output 4 5 20R T type 2 L6 30R 2 L5 20R PD 106 Output 4 L5 20R 4 L6 20R Liebert GXT2 10 kVA 230V Optional additional battery charger for 230V tower model where long runtime and fast recharge are required Liebert GXT2 10 kVA A tower configuration is also 230 240V Tower available in a 230V version and a 220V version with voltage transformer A New View On Configuring Your UPS Each Liebert GXT2 6 kVA and 10 kVA system is shipped with Windows compatible software that allows the user to program a variety of operating parameters This capability allows you to customize the system s performance to your specific requirements providing a new level of power protection control and adaptability The software allows configuration of the following u Output voltage selectable u Enable or disable auto restart u Select frequency converter mode u 60Hz input 50Hz output with no derating bypass is disabled u 50 Hz input 60 Hz output with no derating bypass is disabled 2 Change the low battery warning from the standard two minutes 2 Select how often you want the automatic battery test to occur 2 Disable automatic battery test if necessary 2 Program t
8. AC Power For Business Critical Continuity Liebert GXT2 6 kVA amp 10 kVA UPS Rack Tower Configurable UPS For Network Protection Au wien I NEJ ee p uc EMERSON Compact UPS Systems For High Power Network Rack Applications i LJ TIL ED m 7 ruunt Z ZB ama peer Md RAP RAT RETE 4442 114469687 0200006 o Liebert Solutions To meet these needs for higher capacities in smaller spaces we have developed the Liebert GXT2 6 kVA and 10 kVA UPS systems These true on line double conversion UPS systems feature integrated maintenance bypass as well as optional extended battery runtime Add support Emerson Network Power Service and it all equals greater power assurance and reliability Designed for use in either rack or tower configurations both units offer the smallest available solutions for these power capacities the 6 kVA model at 120 208V output in 4U size or the 10 kVA unit 120 208V output in a 6U package To help meet the need for choosing a single supplier for global applications 220V 230V and 240V 50 60 Hz models are offered with CE and C tick markings On Line UPS Dynamic ypass Power Factor Correction Rectifier Charger Surge Suppression Dual Voltages For Multipl
9. S responds to changes in criticality density and capacity Enterprises benefit 614 841 6022 FAX from greater IT system availability operational flexibility and reduced capital vire inerenti rende equipment and operating costs UE 35028 Piove Di Sacco PD Italy 39 049 9719 111 Phone 39 049 5841 257 FAX Emerson Network Power Asia Pacific 7 F Dah Sing Financial Centre 108 Gloucester Rd Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX liebert com 24 x 7 Tech Support 800 222 5877 Phone 614 841 6755 outside U S While every precaution has been taken to ensure accuracy and completeness in this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2008 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice All names referred to are trademarks or registered trademarks of their respective owners Liebert is a registered trademark of the Liebert Corporation 51 23172 07 08 X Printed in USA Emerson Network Power EmersonNetworkPower com The global leader in enabling Business Critical Continuity 77 AC Power Embedded Computing 77 Outside Plant Racks 8 Integrated Cabinets 77 Connectivity Embedded Power Power Switching amp Controls P Services DC Power E Monitoring Precision Cooling 77 Surge Protection
10. e Applications Simultaneous output voltages of 240 120 208 120 230 115 220 110 or 200 100 VAC provide the flexibility to adapt to multiple load requirements without the need to add additional transformers that take up extra space and add weight Input power factor correction to 0 98 reduces current harmonics and their heating effects Inverter Liebert Delivers 6 kVA Of True On Line Power In A Compact 4U Package Liebert GXT2 6 kVA is the first true on line UPS that combines 6 kVA of power capacity internal batteries and dual output voltage in a single 4U size cabinet This makes it an ideal fit in applications where the power requirements are demanding but rack space is limited Designed for use in either rack or tower configurations the new unit is well suited for installations such as network closets or small computer rooms Modular Wiring And Bypass Capability For installation flexibility the Liebert GXT2 6 kVA allows you to choose from several different wiring configurations made possible by the use of removable power distribution boxes that simply plug into the rear of the UPS The standard box provides terminal blocks for hardwired input and output connections Controls and indicators EN ma HN LINN ka DeL 1 I Ex 1 f I 1 1 L I Liebert GXT2
11. ebert employed Customer Engineers in the U S A and a network of over 900 factory authorized service personnel Emerson Network Power offers critical power system support capabilities geographical coverage and ability to respond that are second to none We offer 24 x 7 emergency dispatch service through our Customer Response Center This facility provides immediate access to factory trained technicians located within your own area who are quickly dispatched to your location when service is required 13 Specifications LIEBERT GXT2 6 KVA LIEBERT GXT2 10 KVA Model Number GXT2 6000RT208 GXT2 10000RT208 Model Rating 4200W 5200VA at 127 220 120 or 240 degrees 8000W 8660VA at 127 220 120 or 240 degrees 4200W 5200VA at 120 208 120 or 240 degrees 8000W 8660VA at 120 208 120 or 240 degrees 4200W 6000VA at 120 240 180 degrees 8000W 10000VA at 120 240 180 degrees 4200W 6000VA at 115 230 180 degrees 8000W 10000VA at 115 230 180 degrees 3780W 5400VA at 110 220 180 degrees 7200W 9000VA at 110 220 180 degrees 3360W 4800VA at 100 200 180 degrees 6400W 8000VA at 100 200 180 degrees DIMENSIONS Unit W x D xH in mm 6 9 x 24 2 x 16 9 176 x 615 x 430 10 5 x 26 0 x 16 9 267 x 660 x 430 WEIGHT Ibs kg Unit 67 30 3 109 49 3 INPUT AC PARAMETERS Nominal Operating Frequenc 50 or 60 Hz Factory Default 60 Factory Default VAC 120 208 VAC at 120 degrees L1 L2 Factory Default Input Phase Angle 120 degrees Allowable Input Phase Ang
12. ection PD HDWR 30 No Bypass Hardwire Terminals Hardwire Terminals PD HDWR MBS 30 With Bypass Hardwire Terminals Hardwire Terminals PD 001 L14 30P 1 L6 30R 1 L14 30R 4 5 15 20R T slot PD 002 2 L6 20R 2 5 15 20R T slot PD 003 L14 30P 2 L6 30R 4 5 15 20R T slot PD 004 4 EN60320 C19 2 L5 30R PD 006 4 L5 20R 2 L6 30R PD 007 4 L6 20R GXT2 10000RT208 Model Number Output Power Connection PD 101 8 5 15 20R T slot 2 L6 30R PD 102 4 5 15 20R T slot 4 L6 20R PD 103 50 4 5 15 20R T slot 4 L6 30R GXT2 PP20KRT208 Model Number Output Power Connection PD 201 4 5 15 20R T slot 4 L6 20R PD 202 4 5 15 20R T slot 4 L6 30R BATTER UPS Model Runtime w Internal Extended Battery Batteries Full Load Cabinet P N Voltage One Cabinet Two Cabinets GXT2 6000RT208 25 min GXT2 6000RT230 38 min GXT2 4500RT230 54 min GXT2 10000RT208 25 min GXT2 240RVBATT 240 VDC GXT2 240TBATTCE 240 VDC 5 min GXT2 240TBATTUL 240 VDC 22 min GXT2 10000R230 GXT2 10000T230 GXT2 10000T220 15 min 43 min 42 min Model Input Voltage Frequenc Output Voltage Frequency Output Rating VA W GXT2 6000RT230 176 276 50 or 60 Hz L L G 220 230 or 240 L L G 6000 4200 176 276 50 or 60 Hz L L G 220 230 or 240 L L G 176 276 50 or 60 Hz L L G 220 230 or 240 L L G GXT2 10000T230 176 276 50 or 60 Hz L L G 220 230 or 240 L L G GXT2 10000T220 176 276 50 or
13. f the Liebert Power Assurance Package While today s smaller rack based UPS systems offer relatively trouble free operation the growing criticality of the systems they support has increased the cost of downtime As a result the need to maintain these smaller UPS systems is increasingly important The Liebert Power Assurance Package is the best solution in the industry for your network power requirements With unprecedented coverage for your small UPS systems there is no better way to protect your business critical network This all inclusive package offers you complete peace of mind for five years including u UPS A compact high quality on line Liebert GXT2 6 kVA or 10 kVA UPS u Start Up Onsite system start up by a certified Service Division of Emerson Network Power Customer Engineer scheduled anytime 24 x 7 This includes removal and disposal of your existing UPS u Preventive Maintenance One preventive maintenance visit completed in year 3 by a certified Emerson Network Power Customer Service Engineer includes 100 Parts Coverage even internal batteries u Full Parts Coverage Your on line Liebert UPS benefits from 100 parts coverage for five years including all internal batteries u On Site Service Should you experience a problem we will dispatch a certified Emerson Network Power Customer Service Engineer to repair or replace your equipment with 4 hour response guaranteed With more than 300 Li
14. he UPS for the number of external battery cabinets connected allowing the UPS to report the correct run time Communications For Power Monitoring And Control The Liebert GXT2 6 kVA and 10 kVA systems offer a variety of communications options to provide the monitoring and control capabilities demanded by today s network computing systems Operation can be monitored using u Liebert MultiLink Automated System Shutdown Software u Liebert Nform Monitoring System u Liebert Universal Monitor And Remote Power Monitor Panels u hird Party Monitoring Systems Liebert IntelliSlot Web Card For enhanced UPS communications and control the Liebert IntelliSlot Web Card will deliver SNMP and web management communications capability to a Liebert GXT2 unit This feature will provide flexibility in how you monitor and control your UPS over the network The card is also easily configurable to work in a standard SNMP implementation and with Liebert MultiLink shutdown software Liebert IntelliSlot Web Card Liebert Power Assurance Package Emerson Network Power Service is your source for start up maintenance warranty and maintenance requirements of your Liebert GXT2 6 kVA and 10 kVA UPS systems Service and support specialists are located everywhere you need them to be Liebert Power Assurance Package Offers A Worry Free UPS Solution For Your Network The Liebert GXT2 6 kVA and 10 kVA UPS systems can be purchased as part o
15. le 120 180 240 degrees Auto sensing on application of AC Restrictions for L N voltages other than 120 VAC Factory Default L1 N L2 N VAC 120 VAC nominal Input Frequency w o Battery Operation 40 70 Hz OUTPUT AC PARAMETERS Factory Default VAC 120 208 VAC 120 degrees L1 L2 Factory Default Output Phase Angle 120 degrees Allowable Output Phase Angle 120 180 240 degrees Auto sensing on initial application of input AC Factory Default L1 N L2 N VAC 120 VAC nominal User Configurable L1 N L2 N VAC 100 110 115 120 127 VAC 3 Frequency 50 Hz or 60 Hz Nominal Waveform Sinewave Overload Rating 200 for 8 cycles 130 for 10 seconds 200 for 8 cycles then shutdown 130 for 60 seconds with transfer to bypass with transfer to bypass ENVIRONMENTAL Operating Tem 32 F to 104 F 0 C to 40 C Storage Tem 5 F to 122 F 15 C to 50 C Relative Humidity 0 to 95 non condensing Operating Elevation Up to 10 000 ft 3000m at 104 F 40 C without deratin Storage Elevation 50 000 ft 15 000 m maximum Audible Noise lt 55 dBA at 1 meter from the rear lt 50 dBA at 1 meter from the front or sides AGENCY Safet UL 1778 cUL Listed Suitable for computer room applications RFI EMI FCC Part 15 Subpart B Class A Surge Immunit IEEE ANSI C62 41 Category amp Transportation ISTA Procedure 1A INTERNAL BATTERY Model Number GXT2 144BATKIT one required GXT2 288RTBKIT two required WEIGHT lbs kc 79 35 8 one required
16. nel plug n play connections for optional additional battery cabinets Use up to three cabinets for extended battery runtime applications Contact Liebert Technical Support for longer backup time solutions Intellislot communications port Utilizes Liebert IntelliSlot Web Card to provide SNMP and web based monitoring and control your UPS u Includes Windows based configuration program Allows various operating parameters to be adjusted and tests to be scheduled This capability enables you to customize the UPS performance to your specific requirements Built in serial communications for use with Liebert MultiLink Automated Shutdown Software Allows you to monitor communication between the UPS and a server and ensures a graceful unattended shutdown 2 Built in closure signals Provides notification to monitoring systems of operating conditions including on battery low battery battery mode shutdown and any mode shutdown uEmergency Power Off EPO Terminal connections for a normally open or normally closed emergency power off switch 2 Wider Input Voltage Window Minimizes Battery Use The Liebert GXT2 10 kVA features a wide input voltage window that allows the UPS to support the critical load without having to transfer to battery extending system availability for when battery back up is truly needed 2 nternal automatic and manual bypass Assures continuity of power to critical loads during
17. rovides notification to monitoring systems of operating conditions including on battery low battery battery mode shutdown and any mode shutdown Emergency Power Off EPO Terminal connections for a normally open or normally closed emergency power off switch Reliability u Wider Input Voltage Window Minimizes Battery Use The Liebert GXT2 6 kVA features a wide input voltage window that allows the UPS to support the critical load without having to transfer to battery extending system availability for when battery back up is truly needed Internal automatic and manual bypass Assures continuity of power to critical loads during system maintenance or in case of internal fault u Self diagnostics Automatically tests unit electronics and batteries Designed to simplify maintenance and troubleshooting u User replaceable hot swappable internal batteries Provide five minutes of runtime at full load Low Total Cost Of Ownership 2 Standard two year warranty 2 Uses less rack space leaving more room for network equipment u Batteries are shielded from heat generating electronic components enhancing battery life 2 Battery cutoff voltage automatically adjusts based on load extending battery life by preventing over discharge of batteries Patented Feature Enhances Reliability The Liebert GXT2 6 kVA includes a patented output neutral bonding feature designed to comply with UL 1778 which
18. system maintenance or in case of internal fault u Self diagnostics Automatically tests unit electronics and batteries Designed to simplify maintenance and troubleshooting u User replaceable internal batteries Provide five minutes of runtime at full load 2 Hot swappable operation Unit features three bays for one power module and two battery modules The chassis contains a bypass switch that allows all modules to be removed without powering down the connected load Liebert GXT2 10 kVA 208V Rear view external battery cabinet External battery 2 Standard two year warranty u Uses less rack space leaving more room for network equipment u Batteries are shielded from heat generating electronic components enhancing battery life Battery cutoff voltage automatically adjusts based on load extending battery life by preventing over discharge of batteries Liebert GXT2 10 kVA 208V with external battery Power module Parallel POD Increase The Flexibility Of Your Liebert GXT2 10 kVA UPS Add Capacity Or Redundancy As Your Needs Grow Many IT managers are finding a need to increase the capacity of their rack mounted UPS With the Parallel POD power output distribution system you can add capacity or redundancy at any time without losing your investment in your Liebert GXT2 10 kVA UPS The Parallel POD enables paralleling of two Liebert GXT2 10 kVA UPS modules to double capacity to 20 kVA A
19. third unit may be added to configure the system for N 1 redundancy raising system reliability Standard Features Offer PD 201 Output 4 5 20R Greater Overall Value T type 4 L6 20R Ports Adapts existing Liebert GXT2 10 kVA UPS to a redundant power Electronic equipment may configuration be installed at the 2 Power output options enable use kiem PD 20X with a wide variety of IT equipment POD installed at nstalis in a rack or a wall the back of the rack increasing Higher Availability T usable space Eliminates single point of failure Output 4 5 20R when configured for redundancy T type 4 L6 30R Input Output Allows two units to be paralleled Power For for capacity and a third added for Paralleled UPS Units redundancy Lowest Total Cost Of Ownership Upgrades your existing Liebert GXT2 10 kVA UPS investment retaining the value of your initial investment Saves floor space and integrates with existing rack environment Equipment shown from Provides the same warranty as back of rack the UPS The Parallel POD will require start up purchase for each GXT2 10000RT208 connected to the system 10 kVA UPS Power Output Distribution Options The standard 10 kVA model includes terminal blocks for hardwired connections of both input and output Optional panels are available to add output receptacles to the rear panel of the unit PD

Download Pdf Manuals

image

Related Search

Related Contents

  Philips O'Neill THE STRETCH headband headset SHO9567BK  USER MANUAL - InOut Communication Systems  TeleWell TW-EA200 & TW-EA500 ADSL modeemi/ reititin/palomuuri    Bally+E-Series+Manual fay  XtremeMac Verona Sleeve  

Copyright © All rights reserved.