Home
Elkay EDFP217C User's Manual
Contents
1. 70682C 1 4 27090C BRACKET HANGER PANEL FOR PARTS VOUR LOCAL DISTRIBUTOR OR CALL 1 800 323 0620 ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK IL 60523 630 574 8484 97705C Rev J 8 07 PAGE 8
2. ED NOTE REFERENCE SEPARATE INSTALLATION INSTRUCTIONS FOR DETAILS ON MP20 SURFACE MOUNTING PLATE EDFP217C B EDFP217RAC EDFPVR217C EDFPVR217RAC EDFP217RAC W MOUNTING PLATE MP20RA SURFACE MOUNTING PLATE BACK PANEL NON 38 1 2 476mm 3 13 16 t 6 5 8 3 13 16 97mm 168mm 97mm 1 5 8 41mm 27 686mm ADA REQUIREMENT FINISHED FLOOR FIG 6 LEGEND NOTE RECOMMENDED WATER SUPPLY LOCATION 3 8 UNPLATED REFERENCE SEPARATE INSTALLATION COPPER TUBE CONNECT STUBBED 1 1 2 38mm FROM INSTRUCTIONS FOR DETAILS ON MP20RA WALL SHUT OFF BY OTHERS SURFACE MOUNTING PLATE B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN STUBBED 1 1 2 35mm FROM THE WALL C RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN STUBBED 6 3 4 168mm FROM THE WALL D 1 1 4 TRAP FURNISHED EDFP217C B EDFP217RAC EDFPVR217C EDFPVR217RAC INSTALLATION INSTRUCTIONS Wall should already be framed for the fountain using the positioning dimensions shown in Figures 3 4 5 or 6 Shown dimensions pertain to installation location framing must support up to 300 Ibs weight These dimensions are required for compliance with ANSI Standard A117 0 Install rough in plumbing as shown in Figures 3 4 5 or 6 Waste line should extend a mini
3. EDFP217C B EDFP217RAC EDFPVR217C EDFPVR217RAC Installation Care Use Manual Soft Sides Fountains with FLEXI GUARD EDFP217C EDFP217RAC Installer To assure you install this model easily and correctly PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING ELECTRICALAND OTHER APPLICABLE CODES After installation leave these instructions inside the fountain for future reference IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT INSTALLER PLEASE NOTE THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS ACOMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM 14 O D TUBE 3 8 O D UNPLATED OPERATION OF QUICK CONNECT FITTINGS COPPER TUBE CONNECT WATER INCET COLD WATER SUPPLY INLET TO COOLER SIMPLY PUSH IN TUBE IS SECURED PUSH IN COLLET TUBE TO ATTACH IN POSITION TO RELEASE TUBE dq 1 Eus PUSHING TUBE IN BEFORE SERVICE STOP PULLING IT O
4. OR LEGEND FIG 4 A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUBBED 1 1 2 38mm FROM WALL SHUT OFF BY OTHERS B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN STUBBED 1 1 2 35mm FROM THE WALL C RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN STUBBED 6 3 4 168mm FROM THE WALL NOTE REINFORCE THE WALL IN THE SHADED AREAS PAGE 3 D 1 1 4 TRAP FURNISHED E 3 8 10mm DIA HOLES FOR SECURING FOUNTAIN TO WALL F 3 8 10mm DIA SLOTS FOR MOUNTING HANGER TO WALL WALL HANGER FURNISHED LOOSE 3 13 16 97mm EDFP217C B EDFP217RAC EDFPVR217C EDFPVR217RAC EDFP217C W MOUNTING PLATE MP20 SURFACE MOUNTING PLATE 18 3 4 BACK PANEL 35 3 4 908mm 29 3 4 756mm 97mm 3 13 16 18 3 4 476mm 15 8 41mm fa 1 IK REQUIREMENT FINISHED FLOOR LEGEND FIG 5 RECOMMENDED WATER SUPPLY LOCATION 3 8 UNPLATED COPPER TUBE CONNECT STUBBED 1 1 2 38mm FROM WALL SHUT OFF BY OTHERS B RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN STUBBED 1 1 2 35mm FROM THE WALL C RECOMMENDED LOCATION FOR WASTE OUTLET 1 1 4 O D DRAIN STUBBED 6 3 4 168mm FROM THE WALL D 1 1 4 TRAP FURNISH
5. UT HELPS NOTE WATER FLOW DIRECTION NOT FURNISHED RELEASE TUBE EDFP217C B EDFP217RAC EDFPVR217C EDFPVR217RAC EDFP217C BACK PANEL 2 5 8 66mm 35 3 4 908 130mm 18 3 4 476mm 3 13 16 97mm 3 13 16 97mm 15 8 41mm 27 686mm ADA REQUIREMENT FINISHED FLOOR FIG 3 LEGEND A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED D 1 1 4 TRAP FURNISHED E 3 8 10mm DIA HOLES FOR SECURING COPPER TUBE CONNECT STUBBED 1 1 2 38mm FROM FOUNTAIN TO WALL WALL SHUT OFF BY OTHERS B RECOMMENDED LOCATION FOR WASTE OUTLET F 3 8 10mm DIA SLOTS FOR MOUNTING 1 1 4 O D DRAIN STUBBED 1 1 2 35mm FROM THE WALL HANGER TO WALL C RECOMMENDED LOCATION FOR WASTE OUTLET G WALL HANGER FURNISHED LOOSE 1 1 4 O D DRAIN STUBBED 6 3 4 168mm FROM THE WALL NOTE REINFORCE THE WALL IN THE SHADED AREAS 97705C Rev J 8 07 PAGE2 EDFP217C B EDFP217RAC EDFPVR217C EDFPVR217RAC EDFP217RAC B BACK PANEL 31 1 4 794mm 3 13 16 97mm 3 13 16 97mm 15 8 27 686mm ADA REQUIREMENT FINISHED FLO
6. g until it reaches a positive stop approximately 3 4 EDFP217C B EDFP217RAC EDFPVR217C EDFPVR217RAC NOTE WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL TIGHTEN NUT ITEM 9 OR 20 ONLY TO HOLD PARTS SNUG IN POSITION DO NOT OVER TIGHTEN Installing back panel When installing back panel item 16 without mounting plate accessory MP20 or MP20RA attach 4 channel braces item 23 as shown in FIG 9 Remove the protective backing from the tape installed on the brace Line up the corresponding holes in the brace and back panel and press firmly in place EDFP217C B EDFP217RAC EDFPVR217C EDFPVR217RAC PARTS LIST PARTNO DESCRIPTION LK464 DRAIN 15005C RETAINING NUT 45662C PUSHBUTTON 45663C PUSH BUTTON SLEEVE 50986C REGULATOR HOLDER 54874 ORIFICE ASSY SEE FIG 7 OR 8 560116 HOUSING ASSY 55997C PEDESTAL 75580C BUBBLER LOCKNUT 61313C REGULATOR 75672C CAP SCREW 112627543890 SCREW 10 24 X 50 PHTC 55996C STRAINER 287822 FOUNTAIN ARM SHORT 28783C FOUNTAIN ARM LONG 27959C FOUNTAIN ARM LONG GLASSFILLER 55000661 BOTTOM COVER PLATE SHORT 55000665 BOTTOM COVER PLATE LONG 28250C BACK PANEL RH ADA 28252C BACK PANEL LH ADA 40045C HEX NUT 27057 REGULATOR MOUNTING BRACKET 100322740560 GASKET VR MODEL ONLY 15009 BUBBLER NIPPLE VR MODEL ONLY 45392C JBUBBLER VR MODEL ONLY 56092C POLY TUBING CUT TO LENGTH 282340 BRACE CHANNEL
7. mum of 2 b1mm through the back panel Run the supply water inlet line through the back panel Install a service stop not provided Turn on supply water and flush thoroughly Install back panel EDFP217C Place the upper edge of the panel above hanger bracket EDFP217C W MOUNTING PLATE Place the upper edge of the panel above mounting plate on the wall Slide the panel down until it engages the mounting plate Be sure back panel is firmly engaged before releasing it Remove bottom access panel from fountain basin and save the screws EDFP217C Install the fountain to the back panel and wall using 4 5 16 x 2 long lag bolts and washers not provided through holes in back panel Tighten securely EDFP217C W WALL PLATE Install the fountain to the back panel using 4 5 16 x 3 4 long screws and washers provided through holes in back panel Tighten securely Remove elbow from end of p trap and attach it to drain tube Reattach elbow to p trap and cut waste tube to required length using plumbing hardware and trap as a guide Make water supply connections from service stop to the 3 8 O D unplated copper tube coming out of the strainer Turn on water supply and check for leaks Newly installed water supply line should be insulated after leak check is completed DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O RINGS MAY RESULT These products are designed to operate on 20 105 PSIG supply line pressure If inlet pre
8. ssure is above 105 PSIG a pressure regulator must be installed in the supply line Any damage caused by reason of connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty Check stream height from bubbler Stream height is factory set at 35 PSI If supply pressure varies greatly from this adjust the screw on regulator item 10 by using a small screwdriver through the small hole in the push button item 3 See Fig 11 Clockwise adjustment will raise stream height and counter clockwise will lower stream height For best adjustment stream should hit basin approximately 6 1 2 165mm from bubbler Replace bottom access panel to fountain using the screws provided Tighten securely TROUBLE SHOOTING AND MAINTENANCE Orifice Assy Mineral deposits on orifice can cause water flow to spurt or not regulate Mineral deposits may be removed from orifice with a small round file not over 1 8 diameter or a small diameter wire CAUTION Do not file or cut orifice materials Stream Regulator If orifice is free of material deposits regulate flow according to instruction 7 stated above Actuation of Quick Connect Water Fittings Cooler is provided with lead free connectors which utilize an o ring water seal To remove tubing from the fitting relieve water pressure push in on the gray collar while pulling on the tubing See Figure 2 To insert tubing push tube straight into the fittin
Download Pdf Manuals
Related Search
Related Contents
Twall 64 User Manual MS dossier web 082015 201410 - 小戸サンライズセーリングクラブ 3M X21 Sistema de administración FRIL - manual usuario Manuel de l`utilisateur Série DP8 - Newall Electronics Inc. SERVICE MANUAL Manual de instruções Vortex 4 - Limpa fundos automáticos para Copyright © All rights reserved.
Failed to retrieve file