Home
Electrolux EI30EF35JS Installation Instructions
Contents
1. INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE BEFORE STARTING Tools You Will Need For leveling legs and Anti Tip Bracket e Adjustable wrench or channel lock pliers e 5 16 Nutdriver or Flat Head Screwdriver e Electric Drill amp 1 8 Diameter Drill Bit Masonry Drill Bit if installing in concrete Forelectrical supply connection e 1 4 amp 3 8 Socket driver or Nutdriver Additional Materials You Will Need e Power Supply Cord or e Copper Electrical Wiring amp Metal Conduit for hard wiring NORMAL INSTALLATION STEPS 1 ANTI TIP BRACKET INSTALLATION INSTRUCTIONS IMPORTANT SAFETY WARNING To reduce the risk of tipping of the range the range must be secured to the floor by properly installed Anti Tip Bracket and screws packed with the range Failure to install the anti tip bracket will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it Serious injury might result from spilled hot liquids or from the range itself If range is ever moved to a different location the Anti Tip Bracket must also be moved and installed with the range Instructions are provided for installation in wood or cement fastened to either the floor or wall When installed to the wall make sure that screws completely penetrate dry wall and are secured in wood or metal When fastening to the floor or wall be sure that screws do not penetrate electrical wiring or plumbing
2. 1a Locate the Bracket using the Template Bracket may be located on either the left or right side of the range Use the information below to locate the bracket if template is not available Mark the floor or wall where left or right side of the range will be located If rear of range is against the wall or no further than 1 1 4 from wall when installed you may use the wall or floor mount method If molding is installed and does not allow the bracket to fit flush against the wall remove molding or mount bracket to the floor For wall mount locate the bracket by placing the back edge of the template against the rear wall and the side edge of template on the mark made referencing the side of the range See Fig 4 Place bracket on top of template and mark location of the screw holes in wall If rear of range is further than 1 1 4 from the wall when installed attach bracket to the floor For floor mount locate the bracket by placing back edge of the template where the rear of the range will be located Mark the location of the screw holes shown in template 1b Drill Pilot Holes amp Fasten Bracket Drill a 1 8 pilot hole where screws are to be located If bracket is to be mounted to the wall drill pilot hole at an approximate 20 downward angle See Fig 5 Fig 4 If bracket is to be mounted to masonry or ceramic floors drill a 3 16 pilot hole 1 3 4 deep The screws provided may be used in wood or concrete mat
3. INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Clearances and Dimensions 1 Provide adequate clearances between the range and adjacent combustible surfaces 2 Location Check location where the range will be installed Check for proper electrical supply and the stability of the floor 3 Dimensions that are shown must be used Given dimensions provide minimum clearance Contact surface must be solid and level RANGE RANGE ELECTRICAL OVERALL CONNECTIONS DIMENSIONS All dimensions for electrical outlet location are maximum 29 1 4 with door handle 25 3 4 t 30 Ti Dashed cubed area shows where the electrical outlet must be installed for flush to he wall installation Centerline of range 49 door open 29 1187 maximum Ne Fig 1 gt 47 Edge 2 5 8 for models cabos with warmer drawers 3 1 2 for models equipped with storage drawers Fig 2 FRONT TYPICAL CABINET INSTALLATION SIDE VIEW VIEW 4 30 gt 30 A i Minimum to 41 ne Minimum to 113 gt wall on either ca 1 18 cabinets on Maximum depth side of range oo L__ oo either side for cabinets above 36 height
4. by the center lowest screw See Fig 13 The ground strap must not be removed unless National State or Local Codes do not permit use of a ground strap NOTE If the ground strap is removed for any reason a separate ground wire must be connected to the separate ground screw attached to the range chassis and to an adequate ground source 4c 3 amp 4 WIRE PERMANENT WIRE CONNECTIONS 3 Wire Permanent Connection follow Steps 1 2 amp 5 below 4 Wire Permanent Connection follow Steps 1 thru 5 below Before wiring the range review the suggested power source location drawings in Fig 3 If connecting to a 4 Wire electrical system new branch circuit or mobile home requires 4 Wire connection 1 3 amp 4 Wire Permanent Connections Follow the manufacturer s installation instructions supplied with the strain relief and install 2 38 4 Wire Permanent Connections Strip insulation away from the ends of the permanent wiring for Line 1 Line 2 Neutral also strip ground wire on 4 Wire Connections Tighten all 3 wire leads to the terminal block Follow wire locations shown in Fig 14 IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed NOTE For 3 Wire Permanent Connections skip Steps 3 amp 4 and continue with Step 5 3 4 Wire Permanent Connection ONLY Disc
5. el soporte antivuelco debe tambi n ser movido e instalado en la estufa Las instrucciones son adecuadas para la instalaci n en pisos de madera o cemento sujeto ya sea en el piso o en la pared Cuando se instala en la pared aseg rese de que los tornillos penetren completamente en la misma y que est n asegurados en madera o metal Cuando se asegura al piso o en la pared aseg rese de que los tornillos no penetren ning n cableado el ctrico o plomer a 1a Ubicaci n del soporte utilizando la plantilla El soporte puede ser ubicado ya sea en el lado izquierdo o derecho de la estufa Use la informaci n indicada a continuaci n para colocar el soporte si no se dispone de la plantilla Fig 4 Marque el piso o la pared donde se colocar el costado izquierdo o derecho de la estufa Si la parte trasera de la estufa ser colocada contra la pared o a no m s de 1 1 4 de la pared cuando ya est instalada usted puede usar el m todo de instalaci n en el piso o en la pared Si tiene moldura instalada y sta no permite que el soporte quede a ras contra la pared retire la moldura o instale el soporte en el piso Para el montaje en la pared ubique la plantilla colocando el borde trasero de la plantilla contra la pared trasera y el borde lateral de la plantilla en la marca hecha indicando el costado de la estufa Ver Fig 4 Coloque el soporte sobre la plantilla y marque la ubicaci n de los agujeros de los tornillos en la pared Si la
6. inferior o la gaveta de almacenamiento Para los modelos con una gaveta calentadora o compartimiento asador sujete la estufa desde el borde superior trasero y trate de inclinarla hacia adelante cuidadosamente INSTALACI N DEL SOPORTE MONTAJE EN EL PISO SOLAMENTE INSTALACI N DEL SOPORTE MONTAJE EN LA PARED O EN EL PISO M x gt le 1 1 4 Tornillo A gt le M s de nivelador e i Tornillo 1 1 4 3 S Montajeen nivelador E Y E la pared 2 a 2 3 E ti sel 2 3 FY Placa Pared mural Montaje en 7 L Soporte Montajeen L Soporte el piso antivuelco el piso antivuelco Fig 5 ys 1716 gt Ns a Costado A EX de la AS estufa i ea Fig 7 eS 2 REQUERIMIENTOS ELECTRICOS DE CONEXION Este artefacto debe ser instalado y puesto a tierra en forma correcta por un t cnico calificado de acuerdo con el C digo Nacional de Electricidad ANSI NFPA No 70 ltima edici n y los requerimientos del c digo local de electricidad Este artefacto debe ser conectado mediante cableado permanente o el Juego de Cable de Alimentaci n El ctrica Cuando instale el cableado permanente no deje el exceso de cable en el compartimiento de la estufa El exceso de cable en el compartimiento de la estufa puede impedir que la tapa de acceso sea reinstalada en forma debida y podr a crear un riesgo el ctrico potencial si los alambres son
7. of range above range top A 49 gt 36 o a N Fig 3 4 30 o clearance below cooking top and at rear of range 30 MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE BOTTOM OF AN UNPROTECTED WOOD OR METAL CABINET OR 24 MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT LESS THAN 1 4 FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO 28 MSG SHEET STEEL 0 015 STAINLESS STEEL 0 024 ALUMINUM OR 0 020 COPPER 0 CLEARANCE IS THE MINIMUM FOR THE REAR OF THE RANGE FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO PREVENT PROPERTY DAMAGE POTENTIAL FIRE HAZARD AND INCORRECT COUNTERTOP AND CABINET CUTS TO ELIMINATE THE RISK OF BURNS ORFIREBY REACHING OVER HEATED SURFACE UNITS CABINET STORAGE SPACELOCATED ABOVE THE SURFACE UNITS SHOULD BEAVOIDED IF CABINET STORAGE IS TOBE PROVIDED THE RISK CAN BE REDUCED BYINSTALLINGA RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5 BEYOND THE BOTTOM OF THE CABINETS IMPORTANT SAFETY INSTRUCTIONS AWGN if the information in this manual is not followed exactly a fire or electrical shock may result causing property damage personal injury or death e Achild or adult can tip the range and be killed e Verify the anti tip device has been installed to floor or wall Ensure the anti tip device is re engaged when the range is moved to floor or wall e Do not operate the range without the anti tip device in place and engaged e Failure to
8. 12 5 KW 16 6 22 5 KW 12 6 18 5 KW 1 3 8 in 1 3 8 in 1 1 8 in 1 3 8 in 40 50 Amp 50 Amp Fig 10 Separate Strain Relief before installation Install Strain Relief here Fig 11 4A POWER CORD CONNECTIONS 4 Wire Connection Instructions Refer to Fig 12 Before wiring the range review the suggested power source location drawing in Fig 3 If connecting to a 4 Wire electrical system new branch circuit or mobile home requires 4 Wire connection 1 Follow the manufacturer s installation instructions supplied with the strain relief and install Also see Figs 9 10 amp 11 2 Insert the end connectors for Line 1 Line 2 and Neutral and tighten securely to the terminal block IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed 3 You must disconnect the ground strap Remove the factory installed ground screw amp plate to release the copper ground strap from the frame of the appliance Cut and discard the copper ground strap amp plate KEEP the ground screw 4 Connect the ground wire Green lead with the eyelet to the frame of the appliance with the ground screw using the same hole in the frame where the ground screw was originally installed See Fig 12 5 Make sure all screws are tightened securely and replace the r
9. AL O DE MADERANO PROTEGIDO O 24 MINIMO CUANDO LA PARTE INFERIOR DE UN ARMARIO DE METAL O DE MADERA ESTA PROTEGIDA CON CARTON RETARDANTEA LAS LLAMAS DE NO MENOS DE 1 4 CUBIERTO CON CHAPA DEACERO NO INFERIOR AL No 28 MSG ACERO INOXIDABLE DE 0 015 ALUMINO DE 0 024 O COBRE DE 0 020 EL ESPACIO LIBRE DE 0 ES EL MINIMO PARA LA PARTE TRASERA DE LA ESTUFA SIGA TODAS LAS DIMENSIONES INDICADAS ANTERIORMENTE PARA EVITAR DA OS MATERIALES RIESGOS DE INCENDIO Y CORTES INCORRECTOS DELOS ARMARIOS Y DELAS MESADAS PARA ELIMINAR EL RIESGO DE QUEMADURAS O INCENDIOS AL PASAR SOBRE LOS ELEMENTOS CALIENTES SE DEBE EVITAR COLOCAR ARMARIOS DE ALMACENAMIENTO SOBRE LA ESTUFA SI SEINSTALAN ARMARIOS SOBRE LA ESTUFA SE PUEDEN REDUCIR TALES RIESGOS INSTALANDO UNA CAMPANA EXTRACTORA QUE SE PROYECTE HORIZONTALMENTE UN MINIMO DE 5 MAS AFUERA DE LA PARTE INFERIOR DE LOS ARMARIOS INSTRUCCIONES IMPORTANTES DE SEGURIDAD Riesgo de volcamiento YOM si no se sigue estrictamente la informaci n de o este manual se puede producir un incendio o un choque el ctrico que Un ni o o adulto puede volcar la estufa y acabar cause da os materiales lesiones corporales o fatales muerto Verifique que se haya instalado el dispositivo Notas Importantes para el Instalador antivuelco en el piso o en la pared Lea todas las instrucciones indicadas en estas instrucciones de instalaci n antes de instalar la estufa aver e Saque todo el material de empaque del compartimiento d
10. E 5 Conexiones permanentes trifilares y tetrafilares Aseg rese de PLACA DE e CONEXION y GN que todas las tuercas est n firmemente apretadas y vuelva a colocar la A TIERRA D cubierta de acceso trasera Ver Fig 9 i 5 TIERRA TIERRA D APROPIADA NOTA Las conexiones de compresi n no terminadas del cableado de campo Sy EBNExIGN deben ser ajustadas a aproximadamente 22 pulg lbs Y PERMANENTE TETRAFILAR CABLE 5 DESLICECON CUIDADO LA ESTUFA HASTA SU LUGAR M ONEXION TERMINAL DE CONEXION DEFINITIVO TIERRA A TIERRA Fig 15 Asegurese de proveer todos los espacios libres adecuados y las dimensiones mostradas en las Figs 1 2 y 3 en la Pagina 1 antes de mover la estufa a su lugar definitivo Ubicacion de la placa de serie La placa de serie esta ubicada Deslice cuidadosamente la estufa hacia la abertura del gabinete a la vez que inserta el tornillo nivelador trasero en el SOPORTE ANTIVUELCO VERFICANDO QUE QUEDE BIEN ENGANCHADO Ver Fig 7 Aseg rese de en el costado derecho del marco delantero inferior del electrodom stico que el cord n de alimentaci n quede plegado en el resto del rea abierta del piso detr s de la gaveta de almacenamiento o gaveta calentadora de la estufa Aseg rese de verificar la nivelaci n de la estufa a Ubicaci n de la placa de serie
11. ILARY TETRAFILAR 3 Conexi n trifilar permanente siga los pasos 1 2 y 5 incluidos a continuaci n Conexi n Trifilar Conexiones instaladas en la f brica NO AFLOJAR Conecte el Conecte alambre L nea 1 neutro aqu blanco o central Tablero de pz q bornes CINTA DE gt CONEXION C Conecte 2 L nea 2 g aqu m TORNILLO a Y PLACA NOTAS Instale el buje sujetacable El alambre central o blanco debe estar siempre instalado en el borne central del tablero de bornes Fig 13 PARA conexiones permanentes trifilares y tetrafilares 4 Conexi n tetrafilar permanente siga los pasos 1 al 5 que se encuentran m s abajo Antes del cableado de la estufa examine los dibujos de la ubicaci n sugerida para la fuente de alimentaci n en la Fig 3 Si est conectando a un sistema el ctrico tetrafilar un circuito de derivaci n nuevo o casa rodante requieren conexi n tetrafilar 1 Conexiones permanentes trifilares y tetrafilares Siga las lt 4 APRIETE LOS 3 CABLES TERMINALES Tablero de bornes instrucciones de instalaci n del fabricante suministradas con el sujetacable e instale 2 Conexiones permanentes trifilares y tetrafilares Desforre el aislamiento de los extremos del cableado permanente para la L nea 1 L nea 2 Neutro adem s desforre el alambre de conexi n a tierra en las conexiones tetrafilares Apriete los 3 conductores hacia el tablero de bornes Siga la
12. apretados Conecte solamente como se indica en la secci n CONEXIONES DEL CABLEADO PERMANENTE en el Paso 4c Cuando use tubo flexible o cable de estufa use un sujetacable o conector flexible Ver Fig 11 2a Modelos con el cord n el ctrico conectado en la f brica NOTA Algunos modelos vienen equipados con cord n el ctrico de tres 3 conductores instalado en la f brica La instalaci n en casas rodantes en instalaciones de circuitos de derivaci n 1996NEC o en reas donde los c digos locales no permitan la puesta a tierra a trav s del conductor neutro se debe Usar un juego de cord n el ctrico de cuatro 4 conductores para 125 250 voltios m nimo y marcado para uso con estufas INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 30 Consulte la Tabla del Tama o de la Abertura de Conexi n de la Estufa Figs 9 y 10 para la informaci n sobre los amperes del juego de cord n Los bornes en los extremos de los almabres deben ser de anillo cerrado u horquillas abiertas con extremos dirigidos hacia arriba 2b MODELOS QUE REQUIEREN EL JUEGO DE CABLE DE ALIMENTACION ELECTRICA PUEDE OCURRIR RIESGO DE INCENDIO O CHOQUE ELECTRICO SI SE USA UN JUEGO DE CABLE DE ESTUFA DE CALIBRE INCORRECTO SI NO SE SIGUEN LAS INSTRUCCIONES DE INSTALACION O SI NO SE USA EL SOPORTE DEL SUJETACABLES Este artefacto puede ser conectado mediante un cable de alimentaci n el ctrica Se debe usar solamente un juego de cable de alimen
13. ca de montaje del cable Fig 9 Tabla del Tama o de la Abertura de Conexi n de la Estufa Informaci sobre la potencia nominal en amperios del Juego de Cable de Alimentaci n Ver la placa de serie en la estufa para los datos sobre la potencia nominal en kilovatios Ver la placa de serie en la estufa para la potencia Nominal del nominal en kilovatios Juego de 120 240 Voltios 120 208 Voltios cable Di metro pulg de la Abertura de Conexi n de la Estufa Juego de Cableado cable Permanente Potencia 8 8 16 5 KW 7 9 1 16 6 22 5 KW 12 Fig 10 2 40 50 Amp 1 3 8 1 1 8 1 50 Amp 1 3 8 1 3 8 Sujetacable Separe el Placa de sujetacable antes montaje gt gt de la instalaci n Fig 11 4A CONEXIONES DEL CORDON DE ALIMENTACION Instrucciones para Conexi n Tetrafilar Consulte la Fig 12 Antes del cableado de la estufa revise los dibujos de las ubicaciones sugeridas para la fuente de alimentaci n en la Fig 3 Si se va a conectar a un sistema el ctrico tetrafilar los circuitos de derivaci n nuevos o las casas rodantes requieren conexi n tetrafilar 1 Siga las instrucciones de instalaci n del fabricante suministradas con el sujetacable e instale Adem s vea las Figs 9 10 y 11 2 Inserte los conectores de extremo para la L nea 1 L nea 2 y Neutro y apriete firmemente en el tablero de bornes NOTA IMPORTANTE NO AFLOJE las conexiones de tuerca instalada
14. e Ground screw amp ground plate NOTES Install strain relief bushing Center or white wire must always be attached to the center terminal on block Fig 13 FOR 3 amp 4 Wire Permanent Connections Terminal block Tighten all 3 i wire leads Ground plate Ground screw Ground strap Fig 14 Note Non terminated field wire compression connections must be set at approximately 22in lbs Always use 10 ga wire or larger of 20 GROUND PLATE gt 20 PROPER Y GROUND FOR oy 4 WIRE PERMANENT a a GROUND CONNECTION E WIRE LEAD SCREW Fig 15 Serial Plate Locations 7 Serial plate location Serial plate is located on the lower right front frame of the appliance Alternate location may be under cooktop INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 30 LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO IMPORTANTE CONSERVE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD LEA Y CONSERVE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA Espacios Libres y Dimensiones 1 Provea espacios libres adecuados entre la estufa y las superficies combustibles adyacentes 2 Ubicaci n Revise el lugar donde ser instalada la estufa Verifique el suministro de energ a el ctrica y la estabilidad del piso 3 Es esencial que se usen las dimensiones que se muestran Las dimensione
15. ear access cover See Fig 9 4 Wire Connection 3 Factory installed connections DO NOT LOOSEN Connect neutral white or center here Connect line 1 here Connect line 2 Cut ground here strap Discard ground strap amp ground plate Connect green insulated copper ground wire with ground screw here NOTES Install strain relief bushing Center or white wire must always be attached to the center terminal on block Fig 12 INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE or 4B POWER CORD CONNECTIONS 3 Wire Connection Instructions For existing installations ONLY Refer to Fig 13 1 Follow the manufacturer s installation instructions supplied with the strain relief and install Also see Figs 9 10 amp 11 2 Insert the end connectors for Line 1 Line 2 and Neutral and tighten securely to the terminal block See Fig 13 IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the terminal block Electrical failure or loss of electrical connection may occur if these 3 nuts are loosened or removed 3 Make sure all connections are tightened securely and replace the rear access cover See Fig 9 Grounding Instructions 3 Wire Connections only A ground strap is installed on this range which connects the center terminal of the terminal block Neutral to the range chassis The ground strap is connected to the range
16. el Aseg rese de que el dispositivo antivuelco se haya reacoplado cuando horno antes de conectar el suministro de gas y de electricidad a mueva la estufa sobre el piso o a la pared la estufa No utilice la estufa sin el dispositivo antivuelco instalado y acoplado Observe todos los c digos y reglamentos vigentes e Aseg rese de dejar estas instrucciones con el usuario Si no se siguen estas instrucciones se puede provocar la muerte o uemaduras graves en ni os y adultos eee q 9 y Aviso importante al consumidor Mantenga estas instrucciones con su Gu a de Uso y Cuidado para referencia futura Al igual que con cualquier electrodom stico que genere calor Soporte i i F A eee existen ciertas precauciones de seguridad que usted debe antivuelco seguir Tales precauciones se encuentran en la Guia de Uso y Cuidado l ala atentamente Aseg rese de que la estufa est bien instalada y sea puesta a Tornillo nivelador de la estufa Para verificar si el soporte antivuelco est instalado correctamente tierra en forma debida por un instalador calificado o un t cnico de sostenga el borde trasero de la parte trasera de la estufa usando ambos servicio on brazos e Aseg rese de que el revestimiento de la pared alrededor de la estufa pueda resistir el calor generado por la estufa Intente inclinar la estufa hacia adelante con cuidado Si est instalada Para eliminar la necesidad de tener que pasar sobre los correctamente la es
17. erial Use a 5 16 nut driver or flat head screwdriver to secure the bracket in place See Fig 6 1c Level and Position Range Level range by adjusting the 4 leveling legs with a wrench Note A minimum clearance of 1 8 is required between the bottom of the range and the leveling leg to allow room for the bracket Use a spirit level to check your adjustments Slide range back into position See Fig 7 Visually check that rear leveling leg is inserted into and fully secured by the Anti Tip Bracket by removing lower panel or storage drawer For models with a Warmer Drawer or broiler compartment grasp the top rear edge of the range and carefully attempt to tilt it forward FASTEN BRACKET FLOOR MOUNTING ONLY gt le More Than FASTEN BRACKET watt or FLOOR MOUNTING p gt 1 1 4 Max Leveling Leg lt Leveling Leg 1 1 4 H Wall Mount 5 5 3 Y ASS ORR ty Wall Plate Wall L 4 a mi rt Floor Mount Lanti Tip Bracket Floor Mount Lanti Tip Bracket Fig 5 Fig 6 Ze 11 16 Range Side Fig 7 2 ELECTRICAL CONNECTION REQUIREMENTS This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI NFPA No 70 latest edition and Local Electrical Code requirements This appliance may be connected by means of permanent wiring or power supply cord k
18. follow these instructions can result in death or serious burns to children and adults y Tip Over Hazard Range n leveling Si Anti Tip bracket To check if the anti if B anti tip bracket is installed properly use both arms and grasp the rear edge of range back Carefully attempt to tilt range forward When properly installed the range should not tilt forward Refer to the anti tip bracket installation instructions supplied with your range for proper installation im portant Notes to the Installer Read all instructions contained in these installation instructions before installing range Remove all packing material from the oven compartments before connecting the gas amp electrical supply to the range Observe all governing codes and ordinances Be sure to leave these instructions with the consumer Important Notes to the Consumer Keep these instructions with your owner s guide for future reference As when using any appliance generating heat there are certain safety precautions you should follow These are listed in the Use amp Care Guide read it carefully Be sure your range is installed and grounded properly by a qualified installer or service technician Make sure the wall coverings around the range can withstand the heat generated by the range To eliminate the need to reach over the surface elements cabinet storage space above the elements should be avoided p n 316454912 rev C Espa ol P ginas 5 8
19. it When installing permanent wiring do not leave excess wire in range compartment Excess wire in the range compartment may not allow the rear access cover to be replaced properly and could create a potential electrical hazard if wires become pinched Connect only as instructed under Permanent Wire Connections in Step 4c When using flexible conduit or range cable use flex connector or range cable strain relief Fig 11 2a Models with factory connected power supply cord NOTE Some models may have a factory installed three 3 conductor power supply cord Mobile home installations new branch circuit installations 1996NEC or areas where local codes do not permit grounding through neutral require a four 4 conductor power supply cord kit rated at 125 250 volts minimum and marked for use with ranges See range connection opening size chart Figs 9 amp 10 for cord kit ampere rating information Terminals on end of wires must be either closed loop or open end spade lugs with upturned ends INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE 2b MODELS REQUIRING POWER SUPPLY CORD KIT RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF AN INCORRECT SIZE RANGE CORD KIT IS USED THE INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED OR STRAIN RELIEF BRACKET IS DISCARDED This appliance may be connected by means of a power supply cord Only a power supply cord kit rated at 125 250 volts minimum and marked for use with ranges shall be u
20. onnect the ground strap Remove the factory installed ground screw amp plate to release the factory installed copper ground strap from frame of the appliance Cut and discard the copper strap from the terminal block KEEP the ground screw ground plate and go to Step 4 4 4 Wire Permanent Connection ONLY Connect the ground wire lead Green to the frame of the appliance using the ground screw amp plate as shown in Fig 15 Be sure to install using the same hole in the frame where the ground screw was originally installed 5 38 4 Wire Permanent Connections Make sure all connections are tightened securely and replace the rear access cover See Fig 9 NOTE Non terminated field wire compression connections must be set at 22 in Ibs or greater Always use 10 gauge wire or larger 5 CAREFULLY SLIDE RANGE INTO FINAL LOCATION Be sure to provide all the adequate clearances and dimensions shown in Figs 1 2 amp 3 before moving appliance into final location Carefully slide range into final position while inserting rear leveling leg into and FULLY ENGAGING THE ANTI TIP BRACKET See Fig 7 Make sure the power cord folds into the remaining open floor area behind the range Warmer or storage drawer Be sure to check the level of the range 4 3 Wire Connection 3 Factory installed connections DO NOT LOOSEN Connect neutral white or center here Connect line 1 here Terminal p block gt Connect line 2 her
21. para conexi n trifilar para instalaciones existentes SOLAMENTE Consulte la Fig 13 1 Siga las instrucciones de instalaci n del fabricante suministradas con el sujetacable e instale Adem s vea las Figs 9 10 y 11 2 Inserte los conectores de extremo para la L nea 1 L nea 2 y Neutro y apriete firmemente en el tablero de bornes NOTA IMPORTANTE NO AFLOJE las conexiones de tuerca instaladas en la f brica que aseguran el cableado de la estufa en el tablero de bornes Se puede producir una falla el ctrica o p rdida de la conexi n el ctrica si estas 3 tuercas son aflojadas o retiradas 3 Aseg rese de que todas las conexiones est n firmemente apretadas y vuelva a colocar la cubierta de acceso trasera Ver Fig 9 Instrucciones para la Puesta a Tierra para conexiones trifilares solamente Esta estufa tiene instalada una cinta de conexi n a tierra que conecta el borne central del tablero de bornes neutro al chasis de la estufa La cinta de conexi n a tierra est conectada a la estufa mediante el tornillo central m s inferior Ver Fig 13 La cinta de conexi n de tierra no debe retirarse a menos que el c digo nacional estatal o local no permitan el uso de una cinta de conexi n a tierra NOTA Si por cualquier motivo se retira la cinta de conexi n a tierra se debe conectar un alambre de tierra separado al tornillo de tierra instalado en el chasis de la estufa y a una tierra adecuada 4c CONEXIONES DEL CABLEADO PERMANENTE TRIF
22. parte trasera de la estufa est a m s de 1 1 4 de la pared cuando ya est instalada instale el soporte en el piso Para el montaje en el piso ubique el soporte colocando el borde trasero de la plantilla donde quedar ubicada la parte trasera de la estufa Marque la ubicaci n de los agujeros de los tornillos mostrados en la plantilla 1b Taladre agujeros pilotos e instale el soporte Taladre un agujero piloto de 1 8 donde se vayan a instalar los tornillos Si el soporte va a ser instalado en la pared taladre un agujero piloto en un ngulo descente de aproximadamente 20 Ver Fig 5 Si el soporte va a ser instalado en pisos de mamposter a o de cer mica taladre un agujero piloto de 3 16 y 1 3 4 de profundidad Los tornillos provistos pueden ser usados en materiales de madera o concreto Use una llave de tuerca de 5 16 o un destornillador de punta plana para asegurar el soporte en su lugar Ver Fig 6 1c Nivele y ubique la estufa Nivele la estufa ajustando los cuatro 4 tornillos niveladores con una llave NOTA Se debe dejar un espacio libre m nimo de 1 8 entre la parte inferior de la estufa y los tornillos niveladores a fin de dejar espacio para instalar el soporte Use un nivel de burbuja de aire para verificar los ajustes Deslice la estufa de nuevo a su lugar Ver Fig 7 Verifique visualmente si el tornillo nivelador trasero est insertado y firmemente asegurado por el soporte antivuelco retirando el panel
23. s en la f brica que aseguran el cableado de la estufa en el tablero de bornes Se puede producir una falla el ctrica o p rdida de la conexi n el ctrica si estas 3 tuercas son aflojadas o retiradas 3 Usted debe desconectar la cinta de conexi n a tierra Retire el tornillo y placa de tierra instalada en la f brica para soltar la cinta de conexi n a tierra de cobre del marco del electrodom stico CONSERVE el tornillo de tierra 4 Conecte el alambre de puesta a tierra Verde con el ojal en el marco del electrodom stico con el tornillo de tierra usando el mismo agujero del marco donde estaba originalmente instalado el tornillo de tierra Ver Fig 12 5 Aseg rese de que todas las tuercas est n firmemente apretadas y vuelva a colocar la cubierta de acceso trasera Ver Fig 9 Conexi n Tetrafilar Conexiones instaladas en la f brica NO AFLOJAR Conecte aqu el alambre neutro blanco o central Conecte L nea 1 aqui Conecte L nea 2 Corte la cinta aqui de conexi n a tierra Descarte la cinta y la placa de conexi n a tierra Conecte aqu el alambre de cobre verde aislado de puesta a tierra con el tornillo de tierra NOTAS Instale el buje sujetacable El alambre central o blanco debe estar siempre instalado en el borne central del tablero de bornes Fig 12 INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 30 04B CONEXIONES DEL CORDON DE ALIMENTACION Instrucciones
24. s indicadas proveen los espacios libres m nimos La superficie de contacto debe ser firme y nivelada DIMENSIONES GENERALES CONECCIONES ELECTRICAS VISTA VISTA DE LA ESTUFA DE LA ESTUFA DE FRENTE LATERAL La profundidad considerando la jaladera de Todas las dimensiones oj po la puerta es de 28 13 13 plg para la ubicaci n del A tomacorriente el ctrico lt 4 30 gt FAAN son m ximas A i io mini gt e il Esapcio m nimo A 41 3 gt El rea del cubo de l nea ae wat a los amiari s Profundidad m xima de puntos muestra donde a la pared en cada OS 0 18 l de los armarios arriba 48 112 L nea se debe instalar el lado de la estufa sobre en a er lado de la cubierta Maxi central tomacorriente el ctrico una altura de 36 pg wy ES de la estufa aximo de la estufa i gt para instalaci n a ras A at 4 25 gt de la pared E y 3e TD Puerta ee Borde de abierta sp 29 718 TZ gt 47 la pared 44 5 8 i por 2 5 8 para modelos equipados con A gavetas de calentamiento y A 3 1 2 para modelos equipados con _ Fig 1 gavetas de almacenamiento Fig 2 Fig 3 Espacio libre de 0 debajo de la cubierta y en la parte trasera de la estufa ESPACIO LIBRE MINIMO DE 30 ENTRE LA CUBIERTA DE COCINAR DE LA ESTUFA Y LA PARTE INFERIOR DE UN ARMARIO DE MET
25. s ubicaciones de los alambres que se muestran en la Fig 14 NOTA IMPORTANTE NO AFLOJE las conexiones de tuerca instaladas en la f brica que aseguran el cableado de la estufa en el tablero de bornes Se puede producir una falla el ctrica o p rdida de la conexi n el ctrica si estas 3 tuercas son aflojadas o retiradas NOTA Para las conexiones permanentes trifilares omita los Pasos 3 y 4 y contin e con el Paso 5 3 Conexi n permanente tetrafilar SOLAMENTE Desconecte la cinta de conexi n a tierra Retire el tornillo y placa de tierra instalada en la f brica para soltar la cinta de conexi n a tierra de cobre del marco del electrodom stico CONSERVE el tornillo de tierra la placa de tierra y siga con el Paso 4 4 Conexi n permanente tetrafilar SOLAMENTE Conecte el alambre c terminal de puesta a tierra Verde al marco del electrodom stico usando el tornillo y la placa de conexi n a tierra como se muestra en la Fig 15 Aseg rese de instalarlo usando el mismo agujero del marco donde estaba originalmente instalado el tornillo de tierra onexi n Neutro lt Q PLACA DE CONEXION A TIERRA TORNILLO DE CONEXION A TIERRA CINTA DE CONEXION DE TIERRA Fig 14 NOTA Los campos de la compresi n de las conexiones de los cables no terminadas deben ser usadas utilizando un cable de 10 ga o m s grande y ajustarlos a aproximadamente 22 libras por pulgadas ermanente tetrafilar SOLAMENT
26. sed See Fig 10 for cord kit ampere rating information Cord must have either three 3 or four 4 conductors See Fig 8 Terminals on end of wires must be either closed loop or open end spade lugs with upturned ends Cord must have strain relief properly installed See Steps 4a for 4 Wire or 4b for 3 Wire connections 3 ELECTRICAL CONNECTION TO RANGE The Rear Access Cover must be removed Fig 9 To remove loosen center screw one screw and remove cover The terminal block will then be accessible 3 amp 4 Wire electrical wall Receptacle types recommended mounting orientation on wall Required for new and remodeled installations 4 Wire Wall receptacle 14 50R Allowed for existing installations 3 Wire Wall receptacle 10 50R Fig 8 NOTE Range is shipped from factory with 1 3 8 dia hole as shown To use either 7 8 dia hole or 1 1 8 dia knockouts refer to Fig 9 1 1 8 Dia 7 8 Dia Knockout Hole See Chart See Chart Rear Access Mounting Cover amp amp 1 3 8 Dia Hole See Chart Pocket for Cable Mounting Plate Fig 9 Range Connection Opening Size Chart Supply Cord Kit ampere rating information See serial plate on range for kilowatt rating data Cord Kit Ampere Rating See Serial Plate on Range for KW Rating Diameter inches of Range connection Opening Permanent Wiring 120 240 Volts 120 208 Volts Cord Kit 8 8 16 5KW 7 9
27. taci n el ctrica para 125 250 voltios m nimo y marcado para uso con estufas Ver Fig 10 para la informaci n sobre la potencia nominal en amperios del juego de cable El cable debe tener ya sea tres 3 o cuatro 4 conductores Ver Fig 8 Los bornes en los extremos de los cables deben ser ya sea en bucle cerrado o terminales de horquilla con los extremos girados hacia arriba El cable debe tener un sujetacable debidamente instalado Ver Paso 4a para cables tetrafilares o 4b para cables trifilares 3 CONEXION ELECTRICA A LA ESTUFA Se debe retirar la cubierta de acceso trasera Fig 9 Para retirar afloje el tornillo central un tornillo y retire la cubierta de acceso As se puede tener acceso al tablero de bornes 3 y 4 Tipos de tomacorrientes murales el ctricos trifilares o tetrafilares y orientaci n recomendada del montaje en la pared Requerido para instalaciones nuevas y remodeladas Tomacorriente mural tetrafilar 14 50R Permitido para instalaciones existentes Tomacorriente mural tetrafilar 10 50R NOTA La estufa es embarcada de la f brica con un agujero de 1 3 8 de di metro como se muestra Para usar ya sea el agujero de 7 8 de di metro o los discos removibles de 1 1 8 de di metro Ver la Fig 9 y Disco removible Agujero de de 29mm de di m 22 mm de di m Ver Tabla Ver Tabla Cubierta Placa de Agujero de 35 mm de di m Ver Tabla Cavidad para la pla
28. tufa no deber a inclinarse hacia adelante Consulte elementos se recomienda no instalar armarios arriba los las instrucciones de instalaci n del soporte antivuelco elementos de la cubierta de la estufa proporcionadas con la estufa para instalarlo adecuadamente 5 English Pages 1 4 INSTRUCCIONES DE INSTALACION PARA LA ESTUFA ELECTRICA DE 30 ANTES DECOMENZAR Herramientas Necesarias Para los tornillos niveladores y soporte antivuelco e Llave ajustable o pinzas ajustables N e Llave de tuerca de 5 16 o destornillador gt de punta plana c e Taladro el ctrico y broca de 1 8 de diam broca para taladro de mamposter a si est instalando en concreto Para la conexi n al suministro el ctrico e Llave de cubo o llave para tuercas de Y y 3 8 Materiales adicionales que usted necesitar Cord n el ctrico o e Cableado el ctrico de cobre y conducto de metal para el cableado PASOS DE LA INSTALACION NORMAL 1 INSTRUCCIONES PARA LA INSTALACION DEL SOPORTE ANTIVUELCO ADVERTENCIA DE SEGURIDAD IMPORTANTE Para reducir el riesgo de que la estufa se vuelque es necesario asegurarla al piso instalando el soporte antivuelco y los tornillos suministrados con la estufa Si no se instala el soporte antivuelco la estufa se puede volcar si un ni o se sube a ella Se pueden ocasionar lesiones graves causadas por los l quidos calientes derramados o por la estufa misma Si la estufa es movida a otro lugar