Home

EdgeStar AP510 User's Manual

image

Contents

1. EdgeStar AP510 Portable Air Conditioner Owner s Manual This owner s manual provides instructions on safe installation use and maintenance Please read it carefully and save it for reference SSEdgeStar For information on EdgeStar and to view our full line of products please visit our website http www edgestar com EdgeStar Products Box 81336 Austin Texas 78708 1336 Toll Free 1 866 319 5473 S http www edgestar com Table of contents EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY HAVE OTHER RIGHTS THAT VARY Table of contents FROM STATE TO STATE Thank you Energy saving tips Notes Specifications Safety precautions Parts Installation Control panel Settings Remote control Manual drainage Maintenance Filter Long term storage Troubleshooting Limited warranty O OO 100 100 ION UT G U NI IN IN Fe pom ek pe ek N o This warranty does not cover service trips to deliver pick up repair or install the product or to instruct in proper usage of the product Damages or operating problems resulting from abuse operation outside environmental specifications uses contrary to instructions provided in the owner s manual accidents vermin fire flood improper installation unauthorized service acts of God unauthorized installation or modification or commercial use are excluded from w
2. either gaseous or droplet form will be expelled out the exhaust port of the unit Please take this into account when deciding how to exhaust it Det SS ES Ea i 46 inch PA Assemble the included window kit The window kit is design to adjust to the size of your window opening Once you have sized the kit appropriately to your window place it into your window shut the sash on it and you may affix it into place with screws CAUTION if you feel this type of installation may create an unsafe situation please install the portable air conditioner in another fashion or not at all 3 Place the end of the exhaust hose that is not connected to the portable air conditioner into a hole in the window kit Make sure the other hole in the window kit is either covered up or connected to the intake hose for your portable air conditioner i Fi asttie ES aH panar i es ED Ere 4 If you wish to install the intake hose make sure the plastic intake cover 1s mounted over the lower air intake on the rear of the portable air conditioner Then affix the intake hose to the port on the intake cover and attach the other end of the hose to the other hole in the window kit Running the unit with b
3. temperature is Use the unit within the outside the operational range of 64 operational range of Sak 64 95 F The air conditioner does not Use the unit in a smaller Room is too large seem to cool effectively room There is direct Close curtains or pull down sunlight into the blinds minimize the direct room sunlight into the room Windows or doors Close the windows or are open doors 11 4 Parts eee Cleaning the exterior e Use a soft damp cloth to wipe the body clean e Never use harsh chemicals gasoline etc to clean the portable air conditioner they may cause permanent damage to the surface Filter Notes To keep dust from clogging the unit never use the portable air conditioner without the filter The filter on the back of the unit collects dust contained in the air It must be cleaned periodically to keep the portable air conditioner operating at maximum efficiency We suggest that you clean the filter once every two weeks or more often if it operates in a dusty environment To clean the filter you can use a vacuum cleaner to remove some of the dust Filter cover pleted l 0 0 To replace the filter pull the plastic filter cover up and out Pull the filter out of the 2 Exhaust port 0 0 3 Drain filter cover and insert the new filter Replace the filter cove
4. arranty coverage This warranty does not cover labor incurred 91 days or more after the date of original purchase This warranty does not cover use of EdgeStar products in commercial settings DESCRIPTION OF WARRANTY SERVICE All defective product components covered by this warranty will be repaired or replaced at EdgeStar s option free of charge on a mail in basis to EdgeStar s authorized repair facility during the first 90 days from the date of original purchase All defective product components covered by this warranty will be repaired or replaced at EdgeStar s option on a mail in basis to EdgeStar s authorized repair facility during the time period beginning on the 91 day from the date of original purchase and ending one year from the date of original purchase During this time period parts will be supplied free of charge but labor charges will apply All replacement parts and units will be new remanufacturered or refurbished All products and components replaced by EdgeStar under warranty service become the property of EdgeStar OBTAINING WARRANTY SERVICE Contact EdgeStar for troubleshooting assistance and warranty service authorization at 1 866 319 5473 Please have your order receipt available to confirm the date of purchase Once an EdgeStar authorized representative has confirmed that your product is eligible for warranty service the product must be returned to an EdgeStar authorized repair facility The purchaser
5. emical substances come into contact with the portable air conditioner Do not use the portable air conditioner in the presence of flammable substances or vapors such as alcohol insecticides gas etc Do not use the plug to start or stop the unit There are additional heat sources in the room g Servers computer equipment etc Remove the additional heat sources The filter is dusty or otherwise blocked Clean the filter The air intake or exhaust ports are partially obstructed Remove the obstruction The unit is The air conditioner is too positioned on a hard Move the unit onto a level loud uneven floor and is carpeted surface vibrating Turn the unit on with the power button to deactivate the Timer on feature The LED display seems to show that the air conditioner is on but it is not working The Timer on feature is activated The unit may make these noises for any Ifthe unit is still cooling number of reasons there is nothing to worry without being about defective The unit is making some strange noises like gurgling swishing hissing ping noises etc Limited warranty This EdgeStar product is warranted to be free from defective workmanship and materials for the first year following the date of original purchase Replacement parts will be supplied free of charge for the first year following the date of original purchase Labor will be performed free of charge for the
6. erature In FAN mode the portable air conditioner will blow air but it will not cool the air In DRY mode the portable air conditioner will act as a dehumidifier NOTE in AUTO COOL or DRY modes the portable air conditioner will dehumidify the air The water dehumidified from the air is exhausted out the exhaust port in vapor or droplet form SPEEDS This portable air conditioner has three fan speeds To tell which speed the fan is on look at the control panel The blinking colored bars on the control panel indicate the speed of the fan the faster they blink the faster the fan speed SLEEP While in COOL mode press the SLEEP button on the remote control After an hour has elapsed the set temperature on the portable air conditioner will increase by 2 F After the next hour the set temperature will increase by another 2 F TIMER This feature can turn on or off the portable air conditioner after a set number of hours has elapsed To use the TIMER to turn the unit on turn on the portable air conditioner and set the mode and temperature that you would like Then turn the unit off Now point the remote control at the control panel and press the TIMER button The portable air conditioner will beep if it received the message from the remote Use the up and down buttons on the timer section of the remote to set the amount of time after which you would like the portable air conditioner to turn on Verify that the number in the
7. first 90 days following the date of original purchase WHAT IS COVERED This warranty applies to the original purchaser only and only covers defects in workmanship experienced during operation of the product under normal service maintenance and usage conditions This warranty applies to the purchase and use of this product in residential settings within the United States of America WHAT IS NOT COVERED The following limitations apply to the coverage of this warranty Optional accessories attachments and appearance items are excluded from warranty coverage as is shipping damage and any damage caused by improper voltage or any other misuse including abnormal service handling or usage This warranty does not cover normal wear and tear on parts or replacement of parts designed to be replaced e g filters etc 12 e Ona warm sunny day operate the unit on fan mode for a few hours to 19 Do not yank on the electric cord or place it near a source of heat If the electric completely dry it out cord is damaged it must be replaced by an authorized service agent e Wind the power cord about the storage hooks on the back of the portable air 20 Always use the control panel to start or stop the portable air conditioner conditioner 21 Always allow for air flow around the portable air conditioner of at least 20 22 Always turn off the portable air conditioner when not in use 23 Always turn the portable air conditioner off and unplu
8. g it after use before cleaning before carrying out maintenance and before moving it 24 It the electrical socket is different from the plug have a professionally qualified electrician replace the socket with a suitable one Do not use adapter plugs multiple sockets or extension cords 25 The filter must be used at all times When removing the filter for cleaning turn off the unit and unplug it Problem Possible Causes Solutions 26 Make sure all children are properly supervised around this portable air conditioner The plug is not properly installed Plug the unit in properly into a power outlet Troubleshooting If the portable air conditioner is not working properly it is usually due to a minor problem that the user can handle Before calling customer service refer to the following chart for troubleshooting The air conditioner will not function at all There is insufficient amperage in the power circuit to start the unit Check your fuses refer to the rating label on the back of the unit for Amp draw The unit should be at least 20 away from walls and other obstacles Move the unit The unit is too close to a wall or some other obstacle The unit will overheat if the air intake or exhaust ports are obstructed Remove the The air conditioner starts and obstruction The unit is covered then cuts out ewer function was activated Press the power button to turn the unit back on The room
9. he room Specifications AP510 Power consumption for cooling mode 1200W Noise level lt 56 dbA Net weight 75 pounds 44 h x 21 3 5 w x 18 Dimensions 1 2 d Safety precautions l 2 3 13 14 15 16 17 18 Transport the portable air conditioner in an upright position only If the unit is tipped over make sure it stands upright for at least 3 hours prior to turning it on Always place the unit on a level surface In order to cool the hot air from the exhaust port in the rear of the portable air conditioner must be exhausted outside the room Make sure the portable air conditioner is connected to a grounded power outlet This portable air conditioner is designed to operate in an ambient temperature of 64 95 F This portable air conditioner has been designed for residential use Always turn the portable air conditioner off before unplugging it Do not damage the power cord Do not use this portable air conditioner for functions other than those described in this owner s manual Do not tilt the portable air conditioner Do not cover or obstruct the intake or outlet grills Do not use the portable air conditioner in a wet room such as a bathroom or laundry room to avoid the possibility of shock Do not bend or crush the exhaust hose while in use Do not sit on or place articles on the portable air conditioner Do not touch the portable air conditioner with wet or damp hands Do not let ch
10. ing out of the portable air conditioner A powerful unobstructed airflow is crucial for optimum cooling Keep blinds and curtains closed during the sunniest part of the day Clean the filter often and replace it as needed 5 Close your fireplace damper floor grills and wall grills to prevent cool air from escaping 6 Avoid opening doors frequently 7 Note that each additional person in room adds between 100 150 BTU of heat so the more people in a room the more cooling capacity is required 8 Set the portable air conditioner to maximum cooling and high speed airflow when you first start it up and then adjust the unit to a comfortable setting i Notes The portable air conditioner must be plugged into an appropriate power outlet Refer to the rating label on the back of the unit for more information The portable air conditioner is a compressor driven cooling system The air conditioner has an anti overheating safety feature that can delay the compressor from starting for three minutes after the air conditioner turns on or when a mode change is made If the compressor does not immediately start it is likely because of this feature To protect the compressor from overheating or freezing it will only operate when the ambient temperature is between 64 and 95 F Always unwind the power cord completely before use In all modes but FAN mode the exhaust hose should be used for maximum efficiency and to expel all condensed water out of t
11. is solely responsible for prepaying all shipping related costs to and from the repair facility EdgeStar is not responsible for damage resulting from shipper mishandling or improper packaging Do not return defective product to the place of purchase THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW IT IS LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD ABOVE NEITHER THE MANUFACTURER NOR ITS DISTRIBUTORS SHALL BE LIABLE FOR ANY INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY NATURE INCLUDING WITHOUT LIMITATION LOST REVENUES OR PROFITS OR ANY OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE SOME STATES DO NOT ALLOW THE 13 Thank you Thank you for purchasing an EdgeStar portable air conditioner Rest assured that all EdgeStar products are designed and manufactured to the highest standards We would like you to be able to fully utilize all features of this portable air conditioner so please take the time to read this owner s manual in full prior to using the unit Energy saving tips 1 Use the portable air conditioner for the recommended room size Rooms that are too small can cause the unit to short cycle and work inefficiently Rooms that are too large will never cool completely 2 Be careful not to obstruct the air flow com
12. oth hoses installed will increase both the speed and efficiency of cooling However please note that in areas with exterior temperatures in excess of 90 F it is best to use the unit in single hose mode NOTE These installation steps only cover window installation This portable air conditioner can be installed through a wall or run as a spot cooler Please note that in any installation the exhaust hose should be kept as short as possible with no kinks or extreme turns Also keep in mind the fact that the portable air conditioner will be expelling water vapor and or droplets out the exhaust port Take any appropriate precautions Control Panel ON OFF 1 ON OFF Turns the unit on or off 2 MODE Toggles modes 3 SPEED Adjusts the fan speed 4 UP Adjusts the temperature up 5 DOWN Adjusts the temperature down 6 OSC turns the oscillating louvers on or off the oscillating louvers direct air to the right and left Settings MODES when the unit is switched on it automatically starts in the AUTO mode which is factory pre set to maintain a room temperature of 73 F The other modes are COOL FAN and DRY In COOL mode the desired temperature can be adjusted up or down and the portable air conditioner will cool until the room temperature reaches the selected temperature Please note that in large rooms or high heat situations the portable air conditioner may never bring the temperature down to the desired temp
13. r prior to restarting the 4 Power cord portable air conditioner Exhaust hose Long term storage At the end of the season or whenever you do not plan to use the portable air conditioner for an extended period of time we suggest you take the following steps e Unplug the unit e Manually drain the internal water reservoir e Clean the filter 9 10 display of the portable air conditioner matches the number on the remote Now the number in the portable air conditioner display will begin counting down as the hours pass and as the number reaches 0 the portable air conditioner will turn on To use the TIMER to turn the unit off turn on the portable air conditioner and set the mode and temperature that you would like Now point the remote control at the control panel and press the TIMER button The portable air conditioner will beep if it received the message from the remote Use the up and down buttons on the timer section of the remote to set the amount of time after which you would like the portable air conditioner to turn off Verify that the number in the display of the portable air conditioner matches the number on the remote Now after that number of hours passes the portable air conditioner will turn on Remote Control JP S25PFSS ug 140 NO This portable air conditioner is equipped with a remote control The remote control has a few features TEMP adjust the set tempera
14. ture up and down with the buttons in this section TIMER turn on or off the timer with this section if CONT is selected no timer features are active on the remote FAN the button in this section controls the fan speed MODE the button in this section controls the mode of the portable air conditioner SLEEP OSC this section contains buttons to turn on or off the SLEEP mode and oscillation function Manual drainage This portable air conditioner is designed to exhaust all condensate out its exhaust port However you may want to manually drain the condensate To do this simply roll the portable air conditioner to an area with a drain or put a pan underneath the drain Pull out the rubber drain stopper and all water in the unit s drain pan will drain out Maintenance Notes Always unplug the portable air conditioner before performing cleaning or maintenance Never hose this air conditioner down or attempt to clean it with a dripping wet sponge or cloth 5 Exhaust hose two identical hoses are included with your portable air conditioner you may use them interchangeably or use one as an exhaust hose and one as an intake hose for increased efficiency Front view 6 Air Outlet 7 Louvers automatic left to right movement if selected 8 Control panel 9 Louvers manual up and down adjustment Installation NOTE This portable air conditioner is designed to exhaust all condensate water collected from your air This water in