Home
Drive Medical Design AGF-3E User's Manual
Contents
1. Pushing plug all the way in 9 Adjust Pulse Frequency Turn the Pulse Frequency control to the setting recommended by your medical professional Frequency Hz 50 90 10 10 Adjust Pulse Width Turn the Pulse Width control to the setting recommended by your medical professional Pulse Width us 180 230 11 Adjust Output Turn Amplitude control knob for Channel 1 or 2 clockwise The indicator will light up while the unit is in operation Slowly turn the channel control in a clockwise direction until you reach the setting recommended by your medical professional Repeat for the other channel if both channels are to be used 12 CONCLUDING TREATMENT 12 Turning Unit Off Turn both channel controls to Off Then unplug 13 the electrode lead wires grasping them by the plug not the cord If treatment will be resumed shortly the electrodes may be left on the skin When the electrodes are removed clean the skin and the electrodes thoroughly with mild soap and water If there is skin irritation from tape or gel consult your prescriber Portability Your TENS is portable and may be clipped to a belt shirt pocket bra or other clothing Z CARE AND MAINTENANCE 14 15 Front Cover A removable panel covers the controls for pulse frequency pulse width mode switch and battery compartment Your medical professional may wish to set these control
2. damage The sensation of pain is important because without it vital parts of our bodies might be injured without our knowledge However long lasting persistent pain often called chronic pain once diagnosed serves no apparent purpose TENS is developed to help relieve certain types of chronic and acute pain How Does TENS work TENS or Transcutaneous Electric Nerve Stimulation refers to the transmission of small electrical pulses through the skin to the underlying peripheral nerves The theory of TENS suggests two different modes of operation Conventional high frequency TENS is based on the theory that continuous mild electrical activity may block the pain signal traveling to the brain If the pain signal does not get through to the brain the pain is not felt The second way TENS is thought to work is by stimulating the body s own natural pain control mechanism Low frequency or short bursts of electrical activity may cause the body to release its own pain relieving substances called endorphins Ask your physician or therapist for more details No matter what pain theory is used TENS has been proven useful in pain management for many pain patients INDICATORS AND CONTROLS Power indicator Light Channel 1 Output Indicator Light Channel 1 Output Receptacle Channel 1 On Off and Amplitude Control Frequency Hz Pulse Width Channel 2 On Off and Amplitude Control Channel 2 Output Indicato
3. les lectrodes Les lectrodes doivent tre attach es avec du ruban adh sif Assurez vous que tous les c t s adh rent bien et que l lectrode soit bien fix e sur la peau 5 Fil de plomb de l lectrode Prise de courant mettre les fiches dans les prises Fixer les connecteurs les brancher aux lectrodes 38 INSTRUCTION POUR L UTILISATION 6 Ins rer les fiches dans le socket de l lectrode Ins rer la fiche du connecteur comme indiqu En ins rant ou en retirant les broches du connecteur tenez le connecteur et non le fil pour ne pas l endommager Pour des lectrodes plac es certains endroits il est pr f rable d attacher la fiche du connecteur avant de placer lectrode sur la peau R gler les commandes Assurez vous que la commande d amplitude des circuits 1 et 2 soit en position OFF 8 Connecter le c ble l unit TENS Ins rer la fiche du fil de plomb dans la prise de courante du circuit utiliser 1 et ou 2 Enfoncer tout fait la fiche 9 R gler la fr quence tourner le bouton de contr le de fr quence d impulsions dans la position recommand e par votre m decin Frequency Hz 50 90 40 10 11 R gler la dur e de la pulsation tourner le bouton de commande de dur e de d impulsion dans la position recommand e par votre m decin Pul
4. ner des irritations cutan es Si la th rapie du TENS devient inefficace ou d plaisante la stimulation doit tre inter rompue jusqu ce que son utilisation soit r valu e par un m decin ou un th rapeute A n utiliser que pour les probl mes de douleur sp cifique comme prescrit par le m decin L efficacit d pend du patient Contre indications R action allergique au sparadrap ou au gel Irritation de la peau ou br lure sous l lectrode Si Pirritation cutan e persiste interrompre l utilisation et consulter le m decin INTRODUCTION Qu est ce que la douleur La douleur nous pr vient des blessures corporelles La sensation de douleur est importante parce que sans elle des parties vitales de notre corps pourraient tre affect es sans que nous ne le sachions Toutefois des douleurs de longue dur e ou persistantes sont souvent appel es chroniques et une fois le diagnostique pos elles n ont plus de raison d tre Comment fonctionne le TENS TENS ou Simulateur Nerveux Transcutan Electrique se r f re la transmission de petites impulsions lectriques travers la peau sur les nerfs p riph riques sous jacents Le TENS propose deux modes ou fonctionnement diff rents Conventionnel haute fr quence TENS bas sur la th orie qu une l g re activit lectrique continue peut bloquer l envoi du signal de la douleur au cerveau la douleur n est pas ressentie Le second mode de fonctionnement du TENS est d
5. AGF 3E DUAL CHANNEL STIMULATOR KIT A MAJOR STEP IN PAIN MANAGEMENT ESTUCHE DE ESTIMULADOR DE DOBLE CANAL UN GRAN PASO EN EL TRATAMIENTO DEL DOLOR STIMULATEUR DOUBLE CIRCUIT UNE ETAPE IMPORTANTE DANS LE CONTROLE DE LA DOULEUR WW W DRIVEMEDICAL COM CONTENTS Page Contes ds as 1 Prescribing Ino Malaria 2 EE nee S A EE 3 Indicators and Control oia 4 Pr paration fOr Us Broad 5 6 Instructions for US ana ie 7 9 Concluding Trata 10 Care and Maintenance otra 11 12 Troubles ai dvi eat 13 Technical Specifications near detente nes 14 PRESCRIBING INFORMATION Caution Federal law USA restricts this device to sale by or on the order of a physician Keep out of the reach of children Indications Transcutaneous Electronic Nerve Stimulation TENS Devices are used for the symptomatic relief and management of chronic long term intractable pain and as an adjunctive treatment in the management of post surgical and post traumatic acute pain problems Contraindictions TENS devices can affect the operation of demand type cardiac pacemakers In patients with known myocardial disease or arrhythmias TENS should be used only with consultation and evaluation by a physi cian Do not use TENS on the eyelids Do not place electrodes directly over the carotid sinus nerves or arteries and laryngeal or pharyngeal muscles Do not apply TENS for undiag
6. a new Replace battery with a new they set to values prescribed by one one your medical professional Are electrodes in proper position Check lead wires Be sure all To obtain service contact connectors are firmly seated your supplier Be sure you are using the proper amount of gel Too much or too little can cause problems Replace cord set with another to check for broken wires 15 16 TECHNICAL SPECIFICATIONS Channels Wave Form Pulse Amplitude Pulse Frequency Pulse Width Maximum Charge Power Source Battery Life Size Weight Dual isolated between channels Modified square wave with zero net direct current DC component 0 to 80mA each channel adjustable 500 ohm load 2 to 150 Hz adjustable 60 to 250 microseconds adjustable 20 micro coulombs per pulse 9 volt alkaline battery or similar rechargeable cell 70 hours average usage alkaline 24 x 64 x 95 mm 130 grams including battery All values have a 10 tolerance DEAR USERS To fulfill an important FDA requirement that will help to safeguard patients from electric hazards associated with the lead wires and cables used on many medical devices we have modified our device s output receptacle and lead wires and cables as in below sketch of new version The operation procedures mentioned in this instruction manual are the same Thank you for your attention to this notice New Version Channel 1 Output Indicator Ligh
7. avija de salida se enchufa dentro de la toma de corriente Conectores de clavija se conectan a los electrodos 24 INSTRUCCIONES PARA USO 6 Introduzca la clavija dentro del enchufe del electrodo Introduzca el conector de la clavija dentro del electrodo como se muestra Cuando introduzca o retire el conector de clavija sujete el conector y no el cable para proteger el cord n Para colocar el electrodo en ciertos lugares tal vez sea preferible introducir el conector de clavija antes de colocar con cinta el electrodo sobre la piel Ajustando los controles Aseg rese que los controles de amplitud para los canales 1 y 2 est n en la posici n de apagado OFF Conectando contactos a TENS Introduzca el extremo del enchufe del conjunto del cable principal dentro del enchufe de salida del canal a usarse 1 y o 2 presionando la clavija hasta que est toda adentro Ajustar la frecuencia de pulso Gire el control de frecuencia de pulso para colocarlo en los par metros que le recomend su profesional de salud Frequency Hz 50 90 26 10 Ajustar el ancho de pulso Gire el control de ancho de pulso para colocarlo en los par metros que le recomend su profesional de salud Pulse Width us 180 110 230 250 11 Ajustar salida Gire la perilla de control de amplitud al canal 1 0 2 gir ndola
8. de marche est allum mais l appareil ne fonctionne pas correctement V rifier toutes les commandes Sont elles dans les positions prescrites par votre m decin es lectrodes sont elles dans la bonne position V rifier les fils de plomb Assurez vous que les que les connecteurs sont correctement fix s Assurez vous d avoir utilis la bonne quantit de gel Trop ou trop peu de gel peuvent entra ner un disfonctionnement Remplacer le c ble d alimentation par un autre pour v rifier qu il n y a pas de fil bris ON et indicateur de batterie sont faibles Remplacer la batterie par une nouvelle Aucun indicateur n est allum Remplacer la batterie par une nouvelle Pour la r paration contacter votre fournisseur 45 46 CARACTERISTIQUES TECHNIQUES Circuits Forme de vague Amplitude des impulsions Fr quence des impulsions Charge maximale Source d alimentation Dur e de la batterie Dimensions Poids Double isol entre les circuits Modifier la vague carr e par l l ment de courant continu DC 0 80 mA pour chaque circuit r glable charge 500 ohm 2 150HZ r glable 20 micro coulombs par impulsion Batterie alkaline 9 volts ou similaire rechargeable 70 heures environ alkaline 24 x 64 x 95 mm 130 grammes avec la batterie Toutes les valeurs ont une tol rance de 10 CHERS UTILISATEURS Pour r pondre aux normes stric
9. e stimuler le corps pour qu il agisse de mani re naturelle sur le contr le de la douleur Basse fr quence de petites imputions lectrique peuvent conduire le corps lib rer sa propre substance antidouleur appel e l endorphine Demandez son m decin ou th rapeute des d tails compl mentaires Peu importante la th orie utilis e Le TENS s est av r utile dans le con tr le de la douleur chez beaucoup de patients 35 INDICATEURS ET COMMANDES Indicateur lumineux de puissance Circuit 1 Indicateur lumineux de puissance Circuit 1 Prise de courant Circuit 1 marche arr t et Commande d amplitude Pulse Width zs Frequency Hz Commande de la dur e d impulsion Channel Y Mea US we Circuit 2 marche arr t et Commande d amplitude Circuit 2 Indicateur lumineux de puissance Circuit 2 Prise de courant Commande de fr quence d impulsion 36 PR PARATION LUTILISATION 1 Contr le de la batterie S assurer de l utilisation d une nouvelle batterie 2 Pr parer la peau Avant d appliquer les lectrodes s assurer du placement correct des lectrodes comme indiqu par votre m decin ou th rapeute Chaque emplacement doit tre bien nettoy rinc et compl tement sec 3 Pr paration des lectrodes Appliquer du gel sur le dessous de l lectrode en une mince couche de l paisseur d une couverture de livre Eviter d employer trop de gel 37 4 Placer
10. gracias por su atenci n a este aviso Nueva versi n Canal 1 Luz de indicador de salida Toma de corriente A Canal 1 _ Canal 1 Encendido Apagado y Control de amplitud SITES 785 wo 4 oh 7 x o o Canal 2 Encendido Apagado E y Control de amplitud Canal 2 Luz de indicador de salida Canal 2 Toma de corriente SOMMAIRE Page SOM a is 33 Information pour la Prescription econo icon 34 Introductions tested stone eue ne mnt Mets tatin ds 35 Indicateurs etCoMMandes iaa cie 36 37 38 Instruction pour l utilisation incida debas 39 41 Fir LAN CU ALL iman 42 A LL LE O 43 44 D pannage done a tee 4 D Sp cifications TECHNIQUES iia sand es 46 33 34 INFORMATION POUR LA PRESCRIPTION Pr cautions La loi f d rale USA impose que la vente soit faite par un m decin ou sur prescription m dicale Tenir hors de port e des enfants Indications Le Simulateur Nerveux Transcutan Electrique TENS est utilis pour le soulagement de douleur symp tomatique et le contr le des douleurs chroniques ou comme traitement additionnel dans le contr le des douleurs post op ratoire ou post traumatique aigu s Contrindications Le TENS peut alt rer le bon fonctionnement de certains stimulateurs cardiaques Pour les patients atteints d une maladie connue du my
11. hacia la derecha La luz del indicador se encender mientras la unidad est en operaci n Gire lentamente hacia la derecha el control de canal hasta que logre los par metros recomendados por su m dico Repita los mismos pasos para el otro canal si es que usa ambos canales CONCLUYENDO TRATAMIENTO 12 Apagando la unidad Apague ambos controles de canal Luego 13 desconecte los cables conectores del electrodo sujet ndolos del enchufe no del cable Si va a resumir el tratamiento dentro de poco tiempo entonces puede dejar los electrodos sobre la piel Cuando retire los electrodos limpie muy bien la piel y los electrodos con una soluci n suave de jab n y agua Si tiene irritaci n cut nea debido a la cinta o al gel consulte con su m dico Portabilidad Su TENS es port til y puede gancharlo a su cinto bolsa de la camisa brasier o cualquier otra prenda 27 28 CUIDADO Y MANTENIMIENTO 14 15 Cubierta frontal Una cubierta frontal cubre los controles de pulso frecuencia ancho de pulso interruptor de modo y el compartimiento de bater a Tal vez su m dico desee fijar estos controles por usted y pedirle que deje la cubierta en su lugar Bater a Cuando las luces del indicador est n tenues esto quiere decir que debe reemplazar las bater as con otras nuevas tan pronto como pueda Sin embargo el estimulador puede seguir operando por varias horas Para reemplazar la bater a retire la cubie
12. lecci n del paciente Reacci n Adversa Posible reacci n al rgica a la cinta o el gel Posible irritaci n o quemadura cut nea bajo la posici n del electrodo Si la irritaci n cut nea contin a discontin e su uso y consulte con un m dico 19 20 INTRODUCCI N Qu es dolor El dolor advierte a nuestro cuerpo de lesiones Este sistema de advertencia tiene el prop sito de evitar da os adicionales La sensaci n de dolor es importante porque sin l partes vitales de nuestro cuerpo se podr an lesionar sin nuestro conocimiento Sin embargo un dolor largo y persistente por lo general llamado dolor cr nico una vez diagnosticado no sirve de ning n prop sito aparente TENS ha sido desarrollado para ayudar a aliviar ciertos tipos de dolor cr nico y agudo C mo funciona TENS TENS o dispositivos de electro estimulaci n nerviosa transcut nea se refiere a la trans misi n de peque os pulsos el ctricos a trav s de la piel hacia los nervios perif ricos subyacentes La teor a de TENS sugiere dos modos diferentes de operaci n TENS convencional alta frecuencia se basa en la teor a de que una actividad el ctrica leve y continua puede bloquear la se al de dolor que viaja al cerebro Si la se al de dolor no llega al cerebro entonces el dolor no se siente La segunda manera en que se piensa que TENS trabaja es al estimular el mecanismo natural del dolor del propio cuerpo Sesiones cortas o de baja frecuencia de ac
13. nosed pain syndromes until etiology is established Any electrode placement that causes current to flow transcerebrally through the head is not allowed Warnings This device should be used only under the continued supervision of a physician TENS is ineffective for pain of central origin TENS is of no curative value it is a symptomatic treatment which suppresses pain sensation which would otherwise serve as a protective mechanism on the outcome of the clinical process Safety of TENS devices for use during pregnancy or delivery has not been established For external use only Electronic equipment such as EKG monitors and EKG alarms may not operate properly when TENS is in use Precautions Avoid adjusting controls while operating machinery or vehicles Turn the stimulator off before ap plying or removing electrodes Long term stimulation at the same electrode site may cause skin irritation If TENS therapy becomes ineffective or unpleasant stimulation should be discontinued until its use is reevaluated by the physician or therapist Use only for the specific pain problem prescribed by a physician Effectiveness is dependent upon patient selection Adverse Reactions Possible allergic reaction to tape or gel Possible skin irritation or electrode burn under elec trode If skin irritation persists discontinue use and consult a physician INTRODUCTION What is Pain Pain warns our body of injury This warning system is intended to prevent additional
14. nueva Est n los electrones en la posici n adecuada Cheque los cables principales Aseg rese Para obtener servicio que todos los conectores est n conectados p ngase en contacto con su firmemente proveedor Aseg rese de usar la cantidad adecuada de gel Poner muy poca o mucha puede ocasionar problemas Reemplace el conjunto de cord n con otro para checar que no tenga cables rotos 30 ESPECIFICACIONES T CNICAS Canales Dobles aislados entre canales Forma de onda Onda cuadrada modificada con componente de corriente directa neta de cero Amplitud de pulso 0 a 80 mA cada canal ajustable carga de 50 ohm Frecuencia de pulso 2 a 150 Hz ajustable Carga m xima 20 micro coulombios por pulso Fuente de energ a Bater a alcalina de 9V o recargable de las mismas caracter sticas Vida de la bater a Uso promedio de 70 horas alcalina Tama o 24 x 64 x 95 mm Peso 130 gramos incluyendo bater a Todos los valores tienen un 10 tolerancia 31 ESTIMADOS USUARIOS Para cumplir un requisito importante del FDA que ayudar a salvaguardar a pacientes de peligros el ctricos relacionados con los cables principales y los cables usados en dispositivos m dicos hemos modificado el enchufe de salida de nuestros dispositivos y los cables principales y cables de acuerdo al esquema que se incluye debajo de nuestra nueva versi n Los procedimientos de operaci n en este manual de instrucciones son los mismos Muchas
15. ocarde ou atteints d arythmie le TENS ne peut tre utilis qu apr s consultation et valuation par un m decin Ne pas utiliser le TENS sur les paupi res Ne pas placer les lectrodes directement sur les sinus nerveux de la carotide ou les art res et les muscles du larynx et du pharynx Ne pas utiliser le TENS pour des syndromes de douleur non diagnostiqu et attendre que l tiologie soit tablie Aucune lectrode ne doit tre plac e l ou elles pour raient perturber le flux transc r bral par la t te Recommandations L appareil ne peut tre utilis que sous le contr le permanent d un m decin Le TENS est inefficace dans le cas de douleurs d origine centrale Le TENS n a pas un effet curatif c est un traitement symptomatique de la douleur qui limine la sensation de douleur qui servirait autrement de m canisme de protection aux r sultats du processus clinique La s curit d utilisation du TENS sur des femmes enceintes ou lors de l accouchement n a pas encore t tablie A usage externe seulement L emploi du TENS peut alt rer le bon fonctionnement des quipements lectroniques comme le moniteur ECG et l alarme de peut ne pas fonctionner correctement Pr cautions Eviter de r gler les commande lors de l utilisation de machines ou de v hicules Eteindre le stimulateur avant de placer ou de retirer les lectrodes L utilisation d une lectrode pendant une longue p riode au m me endroit peut entra
16. r Light Channel 2 oe Output Receptacle Pulse Frequency Control PREPARATION FOR USE 1 Check Battery Insure that you are using a fresh battery 2 Prepare Skin Before applying the electrodes be sure to confirm correct electrode placement as recommended by your physician or therapist Each location should be washed rinsed and thoroughly dried 3 Prepare Electrodes Apply gel in a thin even layer about the thickness of a match book cover to the bottom of the electrode Avoid using too much gel 4 Attach Electrodes The electrode should be attached with adhesive O tape Be sure that all sides are well taped and that the electrode is held firmly against the skin 5 Electrode Lead Wires Output plug plugs into output receptacle Pin Connectors plug into electrodes INSTRUCTIONS FOR USE 6 Insert pin into Electrode Socket Insert pin connector into electrode as shown When inserting or removing pin connector hold connector not cord to protect cord For some electrode connections it may be preferable to insert the pin connector prior to taping the electrode to the skin Adjusting the Controls Ensure that amplitude controls for both Channels 1 and 2 are turned to the OFF position 8 Connect Leads to TENS Unit Insert receptacle end of lead wire set into the channel output receptacle to be used 1 and or 2
17. rectamente sobre los nervios del seno carot do o arterias ni sobre los m sculos de la laringe o faringe No aplique TENS para s ndromes de dolor no diagnosti cado hasta que se establezca la etiolog a No se permite cualquier colocaci n del electrodo que ocasione flujo de corriente transcerebralmente por medio de la cabeza Advertencias Este dispositivo no debe utilizarse sin la continua supervisi n por parte de un m dico TENS no es efectivo para dolor de origen central TENS no tiene valor curativo Es un tratamiento sintom tico que suprime la sensaci n de dolor que de otra manera servir a como un mecanismo protector sobre el resultado del proceso cl nico La seguridad de los dispositivos TENS para el uso durante el embarazo o el nacimiento no ha sido comprobado nicamente para uso externo Equipo electr nico como monitores de ECG y alarmas ECG pueden no funcionar adecuadamente cuando el TENS est en operaci n Precauciones Evite ajustar los controles mientras est operando maquinaria o veh culos Apague el estimulador antes de aplicar o retirar los electrodos Una estimulaci n prolongada en el mismo sitio del electrodo puede ocasionar irritaci n de la piel Si la terapia con TENS se vuelve inefectiva o no placentera debe descontinuar la estimulaci n hasta que su uso sea evaluado de nuevo por un m dico o terapeuta Utilice la unidad s lo para el problema de dolor espec fico recetado por el m dico La efectividad depende de la se
18. rta frontal vea arriba y saque la bater a Reemplace la bater a con una bater a nueva de 9 volts alcalina o bater as recargables similares teniendo cuidado de colocarlas correctamente Ver diagrama dentro del compartimiento de la bater a Esta unidad TENS est dise ada para usarse solamente con bater as y no puede operar con un cargador el ctrico 16 Cuidado de electrodos Para evitar irritaci n cut nea y asegurar buen contacto con su piel limpie frecuentemente los electrodos de silic n con una soluci n de jab n y agua Permita que se seque completamente antes de usarlos 17 Cuidado de los cables de los electrodos Limpie los cables de los electrodos con un trapo h medo C bralos levemente con talco para que no se enreden y alargar su uso Jason 29 SOLUCI N DE PROBLEMAS Si su unidad TENS parece no estar operando correctamente vea la gr fica de abajo para determinar que puede estar fallando Si ninguna de las medidas corrige el problema entonces la unidad necesitar servicio Las luces del indicador encienden pero Las luces On encendido Ninguno de los indicadores la unidad no funciona adecuadamente y Battery Light luz de la enciende bater a est n tenues Checar todos los par metros de control Est n fijados en los valores que le recet Reemplace la bater a con una Reemplace la bater a con una su doctor nueva
19. s commandes en place et vous demandera de ne pas enlever le couvercle 15 Batterie Si l intensit lumineuse diminue cela signifie que la batterie doit tre remplac e aussi rapidement que possible Toutefois le stimulateur continuera fonctionner pendant quelques heures Pour remplacer la batterie enlever le couvercle voir ci dessus et enlever la batterie Remplacer par une batterie alkaline de 9 volts ou toute autre batterie similaire rechargeable en prenant soin de bien la replacer voir le sch ma l int rieur du compartiment de la batterie Ce TENS est pr vu pour fonctionner uniquement avec des batteries et ne peut pas tre connect un chargeur lectrique 44 16 17 Entretien des lectrodes Afin d viter toutes irritations et assurer un bon contact avec votre peau nettoyer fr quemment les lectrodes en caoutchouc de silicone avec de l eau et du savon Bien s cher avant de les r utiliser Entretien des lectrodes Nettoyer les fils des lectrodes en les essuyant avec un chiffon humide Les enduire l g rement avec du talc afin qu ils ne se m lent pas et qu ils durent plus longtemps Jason DEPANNAGE Si votre TENS semble ne pas fonctionner correctement veuillez vous r f rer au tableau ci dessous pour d terminer la raison Si le probl me persiste votre appareil doit tre envoy l entretien Lindicateur
20. s for you and request that you leave the cover in place Battery Dimming of the Indicator lights signifies that the battery should be replaced with a new one as soon as possible However the stimulator will continue to operate for several more hours To replace battery remove front cover see above and extract battery replace with a 9 volt alkaline or similar rechargeable battery taking care that the battery is inserted correctly See diagram inside battery compartment This TENS unit is designed to be used with batteries only and cannot be operated from a line powered battery charger 16 Care of Electrodes To avoid skin irritation and ensure good contact with your skin clean silicone rubber electrodes with soap and water frequently Allow to dry completely before using 17 Care of Electrode cords Clean the electrode cords by wiping 17 with a damp cloth Coating them lightly with talcum powder will reduce tangling and prolong life Jasa L 14 TROUBLESHOOTING If your TENS unit does not seem to be operating correctly refer to the chart below to determine what may be wrong Should none of these measures correct the problem the unit will need servicing The power indicator lights On and Battery light are None of the indicators light up but unit does not function dim up properly Check all control settings Are Replace battery with
21. se Width us 180 230 R gler la puissance tourner le bouton de commande d amplitude pour le circuit 1 ou 2 dans le sens des aiguilles d une montre Lindicateur restera allum pendant toute la dur e d utilisation de l appareil Tourner lentement le commande du circuit dans le sens des aiguilles d une montre jusqu ce que vous atteigniez la position recommand e par votre m decin R p ter cette op ration pour l autre circuit si les deux circuits doivent tre utilis s 41 42 ARR T DU TRAITEMENT 12 13 Eteindre l unit Tourner les deux commandes de circuits en position OFF Ensuite d brancher les fils des lectrodes D brancher les lectrodes des fils de plomb et non du cordon Si le traitement reprend rapidement les lectrodes peuvent tre laiss es sur la peau Lorsque les lectrodes sont retir es bien nettoyer la peau et les lectrodes avec du savon doux et de l eau S il y a une irritation de la peau due au sparadrap ou au gel consulter le m decin Portabilit Votre TENS est portable et peut tre attach votre ceinture mis dans une poche au soutien gorge ou tout autre v tement Z SOIN ET ENTRETIEN 14 Couverture Un panneau amovible couvre la commande de lo la fr quence d impulsion la dur e de l impulsion le commutateur de mode et l emplacement de la batterie Votre m decin souhaitera probablement mettre le
22. t Channel 1 Output Receptacle _ Channel 1 On Off and Amplitude Controk SER Channel 2 On Off and Amplitude Control Channel 2 Output Indicator Light Channel 2 Output Receptacle 17 18 NDICE P gina ita 18 Informaci n de prescripci n M iia dr 19 INFOdUCCI N 2 sida 20 Indicadores y controles cda 21 Preparaci n para SUUS ici dad 22 23 Instrucciones PAra UU SD viii oia 24 26 Concluyendo el tratamiento hes A 27 Guidado mant nimiento 2 4628220 aaa mentor 28 29 Soluci n de Problemas bo orne di 30 Especificaciones TECHICAS ii aio 31 INFORMACI N DE PRESCRIPCI N Precauci n La ley federal EEUU restringe la venta o uso de este dispositivo s lo por orden de un m dico Mant ngase alejado de los ni os Indicaciones Los dispositivos de electro estimulaci n nerviosa transcut nea TENS se utilizan para aliviar los s ntomas y tratamiento cr nico a largo plazo del dolor resistente al tratamiento y como un tratamiento adyuvante en el manejo despu s de cirug as y despu s de problemas de dolor agudo traum tico Contraindicaciones Los dispositivos TENS pueden afectar la operaci n de los marcapasos cardiacos a demanda En pacientes con enfermedad conocida del miocardio o arritmias TENS debe ser utilizado s lo con la consulta y evaluaci n de un m dico No utilice TENS sobre los parpados No coloque los electrodos di
23. tes de FDA qui permettent de prot ger les patients de chocs lectriques dangereux li s aux fils de plomb et aux c bles utilis s dans beaucoup d appareils m dicaux nous avons modifi les dispositifs de sortie les fils de plomb et les c bles voir ci dessous le sch ma de la nouvelle version Les proc dures d utilisation d crites dans ce manuel d utilisation sont les m mes Merci de vous conformer cette notice Nouvelle version Circuit 1 Indicateur lumineux de puissance m Circuit 1 Prise de courant Circuit 1 ON OFF et Commande d amplitude MIER Circuit 2 ON OFF et Commande d amplitude Circuit 2 Indicateur lumineux de puissance Circuit 2 Prise de courant 47 4 WWW DRIVEMEDICAL COM 99 Seaview Boulevard Port Washington NY 11050 Phone 516 998 4600 Fax 516 998 4601 www drivemedical com
24. tividad el ctrica pueden hacer que el cuerpo libere sus propias sustancias que alivian el dolor llamadas endorfinas Pida a su m dico o terapeuta que le proporcione m s detalles Sin importar cual teor a de dolor se usa ha sido comprobado que TENS es til en el tratamiento de dolor para muchos pacientes que lo padecen INDICADORES Y CONTROLES Luz de indicador de energ a Canal 1 Luz de indicador de salida Canal 1 Toma de corriente Canal 1 Encendido Apagado y Control de amplitud Pulse Width us Frequency Hz Control de Canal 2 Encendido Apagado ancho de pulso y Control de amplitud Canal 2 Luz de indicador de salida Canal 2 Toma de corriente Control de frecuencia de pulso 21 22 PREPARACI N PARA SU USO 1 Cheque la bater a Aseg rese de estar usando una bater a nueva 2 Prepare la piel Antes de aplicar los electrodos aseg rese de confirmar la ubicaci n correcta con su m dico o terapeuta Cada ubicaci n debe ser lavada enjuagada y secada completamente 3 Preparar electrodos Aplique una capa delgada aproximadamente del grosor de una caja de cerillos y uniforme de gel sobre la parte de abajo del electrodo Evite usar mucho gel 4 Anexar los electrodos El electrodo debe ser anexado con cinta D adhesiva Aseg rese que todos los lados est n bien pegados y que los electrodos est n colocados firmemente contra la piel 5 Cables principales del electrodo Cl
Download Pdf Manuals
Related Search
Related Contents
Samsung WA107FA1 Manual de Usuario Manuale tecnico centrale micra CUPANEL - Comfile Technology Planar FPL606-PWXS FR(1.70 MB, PDF) D Einbau- und Bedienungsanleitung RolloTron Schwenkwickler ES Kicker 2008 ZX 450.2 Owner's Manual Samsung MJC-1040I User Manual Hoover C1433010 vacuum cleaner Candy CA-810 Candy CA-710 Candy CA-706 USER`S MANUAL Copyright © All rights reserved.
Failed to retrieve file