Home

Dimplex XL6N User's Manual

image

Contents

1. X Dimplex XLS6N AUTOMATIC XLON MANUAL Mini ULTRA SLIM STORAGE HEATER MODELS XLS6N 6kWh E XL6N 6kWh IPX2 INSTALLATION ano OPERATING INSTRUCTIONS IMPORTANT PLEASE READ THIS LEAFLET CAREFULLY AND RETAIN FOR FURTHER USE NOTE ALSO THE INFORMATION GIVEN ON THE HEATER The installation must be carried out by a competent electrician and should be in accordance with I E E Regulations A Double Pole Switch with a contact separation of at least 3mm on each pole must be provided in the installation The heater is not suitable for connection to a 30A ring circuit Do not position the heater under windows where curtains can contact the heater casing WARNING THE SURFACES ON THIS HEATER CAN BE HOT This heater meets EN60 335 safety requirements However any heater type becomes hot in normal operation Care must be taken to ensure that prolonged skin contact with the heater does not occur WHERE YOUNG CHILDREN INFIRM PERSONS OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE ADEQUATELY GUARDED Contact your installer or the manufacturer for further advice This appliance is very heavy and must be securely fixed to a wall DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE IMPORTANT Due to the newness of materials the heater will produce a slight smell for the first few days of operation ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN CAGED BIRDS OR PERSONS WITH RESPIRATOR
2. board is present secure the heater through the wall bracket slots closest to the wall ii If 100mm 4in skirting is present secure the heater through the outer slots iii If skirting taller than 150mm 6in is present this must be reduced to 150mm 6in over the entire width of the heater plus 25mm 1in at each end Do not fully tighten these screws until the bricks are loaded into the heater as some settling of the heater may occur NOTE NEVER REMOVE THESE SCREWS WITHOUT FIRST UNLOADING THE HEATER ee iy o bi peed Outer slot SS See a zaman RS SS No Skirting Board Yj 400mm 4 Skirting 450mm 6 Skirting 3 Board ee eee ee Uy ee ae Uy Ly yy Wy Le eee ee ee A es LEE EEE ETEK 8 Remove the front panel by removing the two self tapping screws along its bottom edge With hands positioned on each side of the panel lift upwards to unhook the top edge whilst pressing down on the top panel with your thumbs The panel can now be lifted clear and set to one side Discard the packing which had been sandwiched between the inner front and outer front 9 Remove the inner front by removing the screws along its sides As the front insulation is attached care must be taken when lifting this panel from the heater and placing It to one side Remove the internal packing by sliding it up and off the elements taking care not to damage the insulation QO Remove the elementto allow access f
3. 0 335 2 61 EN 61000 3 2 EN 61000 3 3 EN 55014 and EN55104 for Safety amp Electromagnetic Compatibility These standards cover the requirements of the EMC Directives 89 336 amp 73 23 83708 Issue 3 February 2002 0870 7270 101 0870 7270 103 Customer Help Line Product Sales Hedge End Head Office 0870 0777 117 Southampton Hampshire e mail customer services glendimplex com S030 2DF
4. Room Sensor is located at the rear of the right hand side of the heater Remove sensor from plate carefully slide the sensor plate down from its transit position to its operational position Refit sensor to plate 3 Transit Position Operational Position Place the heater on its feet and in the desired position against the wall Ensure the heater is based on a firm level surface at least 75mm from any end wall and at least 250mm below any shelf or similar projection Cut away any gripper rod or carpet which would prevent the heater sitting firmly on the floor 5 Mark the position of the two outside corners of the wall bracket with the heater pushed tight against the wall Remove the wall bracket from the heater by removing the screw at each end Place the heater to one side and reposition the bracket against the wall using the corner marks for alignment Four fixing positions must be chosen for this heater Mark the positions for the fixing holes one at each end Remove the bracket from the wall drill the holes in the positions marked and insert suitable fixings previously described Secure the wall bracket to the wall If mains connection is to be made from the left side at this point the mains lead must be secured to the back of the heater using ties provided in the fixing kit 7 THE FOLLOWING MUST BE APPLIED WHEN FIXING THE HEATER TO THE WALL BRACKET i If no skirting
5. Y COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD IF DURING ANY REASSEMBLY OF THE HEATER A PART OF THE THERMAL INSULATION SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY IT SHOULD BE REPLACED BY AN IDENTICAL PART PREPARATION The heater will arrive separately from its storage bricks 4 bricks will be required 2 Packs Catalogue No XT8300 XLS6N 2 MODEL LIMIT STAT FACTORY SET ONLY Oe CUT aN ROOM STAT m Storage Element CIRCUIT DIAGRAM WARNING This appliance must be earthed Only heat resisting cable min rating T85 should be used The wires in the mains cable will be coloured as follows GREEN amp YELLOW EARTH BLUE NEUTRAL BROWN LIVE SUGGESTED FIXINGS SOLID BRICK BLOCK No 10 Rawlplug fibre inserts 5 5mm drill bit Drill hole 6mm deeper than rawlplug length PLASTERBOARD If possible locate studding and use No 10 woodscrews directly into the wood otherwise M5 rawlplug intersets are suitable NOTE FOR OTHER WALL TYPES e g Timber frame and hollow concrete SEEK SPECIALIST ADVICE FIXING ASSEMBLY 1 ENSURE THAT FIXING KIT AND FEET HAVE BEEN LOCATED BEFORE DISPOSING OF PACKAGING 2 Fit the feet with the open end of the foot to the front of the heater Secure each foot using two taptite screws provided in the fixing kit INSTALLATION INSTRUCTIONS 3 XLS6N MODEL ONLY The
6. implex OPERATING INSTRUCTIONS Millbrook House Grange Drive However if the cutout has operated before following the instructions below determine the cause of the cutout operating If the heater has not obviously or inadvertently been misused e g covered it will be necessary to have the appliance fully checked by a Dimplex Service Agent A list of Dimplex Service Agents is enclosed in the leaflet envelope and should be retained by the user Cutout Reset Button CLEANING To maintain the appearance of the heater wipe occasionally with a dry cloth when the heater is cool Do not use abrasive powders of furniture polish AFTER SALES SERVICE Your Dimplex Storage Heater is guaranteed for one year from date of purchase We undertake to exchange or repair within the period any part found to be defective due to a manufacturing fault applies in the UK only This guarantee in no way prejudices your rights under common law Should you require after sales service please get in touch with the supplier through whom you purchased the appliance or your nearest Service Agent Please do not return a faulty appliance or part of an appliance to us as this may result in transit damage and or delay in providing service Let us know your difficulty quoting the model number and serial number of the appliance We will then take the appropriate action This appliance complies with the European Standards EN 60 335 1 EN 6
7. ition the heater without first obtaining the services of a competent electrician Thermal overload protection This appliance is protected by a thermal safety cutout which will Thermostat amp operate to isolate the electricity Thermal Cutout supply if for example the heater surfaces or grille are obstructed to cause overheating The cutout should not operate if the instructions given in this leaflet and clearances regarding positioning are strictly followed SAFETY INSTRUCTIONS Ventilate rooms well during commissioning 2 Do not move the heater in any way once installed without the services of a competent electrician Do not cover the heater with clothing etc at any time or position furniture close to or against the heater Ensure a clearance of at least 150mm between heaters and curtains ALSO REFER TO COVER PAGE a g gt AUTOMATIC OPERATION Dimplex XL6N and XLS6N Storage Heaters store heat overnight using cheap off peak electricity and discharge this heat the following day The XL6N is preset at the factory to always take a full charge XLS6N models are fitted with an external sensor which measures room temperature and adjusts the input to the heater automatically thus ensuring the most effective use of electricity These operating instructions assume that the correct size of storage heaters have been selected to cater for the heating requirements of the room CE Glen Dimplex UK Ltd X D
8. or the back rows of bricks Loosen the two screws securing the element tails in the ceramic connector block and liftthe element up and out of the heater 11 Carefully fit the bottom rear brick with the narrow end of the recess over the slot in the base insulation Fit the top rear brick with the narrow end of the recess to the top 1 2 Refit the element which had been removed by feeding the tails down through the hole in the base insulation and into the connector block Ensure the element is fully pushed home then securely tighten the two screws in the block Fit the front bricks again with the recess towards the element 13 _ Replace the inner front complete with insulation by locating its bottom edge behind the front lip of the chassis and inserting retaining screws along both sides 1 Lo Feed the mains cable through the cable clamp and make connections as marked on heater Pull back any slack through the clamp and tighten clamping screw WARNING This appliance must be earthed 1 6 Replace outer front panel and grille by hooking the grille into its retaining slot on the top panel and lowering it into position Secure the front panel with the two self tapping screws Tilt a Gite Prine alt ek 17 Check that the screws securing the heater to the wall bracket have been fully tightened IT IS ESSENTIAL THAT ALL SCREWS ARE REPLACED TO ENSURE EARTH CONTINUITY Once installed do not attempt to repos

Download Pdf Manuals

image

Related Search

Related Contents

manual del propietario scooter rs sport 50  JBl OnBeat™ - jbl.waw.pl  SAS (R) 9.1 Companion for OpenVMS Alpha  Operating Manual - Spudnik Equipment Company    Caméras infrarouges pour la Recherche  2000 - Mathématiques académie de Tours  Severin KA 5993  CCP - Cooper Industries  Simuladores del Cuidado Ostómico  