Home
Dimplex BF33ST/DX User's Manual
Contents
1. OR SECTION D FOR MAIN POWER CONNECTION Ll ml WALL SWITCH GROUND G gt m o z 2 gt lt n TM WALL MOUNTED THERMOSTAT WIRING FOR 120 240 VOLT NOTE Before installing the unit complete the following 1 Install main power connection with appropriate voltage as per Section C or Section D 2 Install a 2 conductor wire with ground 3 wires total from the thermostat wall box to the junction box on the unit NOTE Wiring of the thermostat must be completed prior to installing the unit NOTE The following installation instructions are for a single pole thermostat 120 240VOLT INSTALLATIONS Loosen the screw securing the junction box and remove the cover Remove the knockouts if necessary or use the provided cable clamp Pull out the three wires marked 1 2 and G red red and green Remove the wire connector and separate the wires marked 1 amp 2 Connect the red 1 wire from the unit to the white neutral wire from the wall thermostat box by using a wire connector not supplied Connect the other end of the white neutral wire from the thermostat wall box to the red wire from the wall thermostat Connect the red 2 wire from the unit to the black wire from the thermostat wall box by using a wire connector not supplied Connect the other end of the black wire from the thermostat wall box to the black wire from the wall thermostat Connect
2. BF33DX 33 Deluxe ss 22 dci Option Option Included 2 0 BF39ST 39 120 120 208 245 1440 2100 Standard 240 2700 120 120 208 245 1440 2100 BF39DX 39 Deluxe 1240 2700 45 120 120 208 245 1440 2100 Standard 240 2700 BF33ST Option Option N A 2 0 Option Option Included 2 0 BF45ST Option Option N A 2 0 120 120 208 245 1440 2100 BF45DX 45 Deluxe 240 2700 Option Option Included 2 0 NOTE Power ratings shown include the light bulbs and motors 275 watts WARNING The installation of the fireplace unit must comply with the applicable Local and or National Electrical Codes and utility requirements This installation should be entrusted to duly qualified personnel where required by law Ses BY STEP INSTALLATION Note Please read all instructions before installing Rough in framing opening following the recommended dimensions located in Section A Framing Allow 8 of service cable for connecting power supply wire to junction box on fireplace when installing before finishing wall Allow up to 4 feet of service cable for connecting power supply wire to junction box on fireplace when installing after finishing wall Remove the outer jacket and strip the individual conductors 1 2 from the end Loosen the screw securing the junction box cover and remove the cover Remove knockouts if necessary or use the provided cable clamp Place unit in position in t
3. ONS 1 Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit see figure 2 on page 3 2 Ensure that the switch is in the 120 volt position 115 is printed on switch Loosen the screw securing the junction box cover and remove the cover Remove the knockouts if necessary or use the provided cable clamp Pull out the four wires marked L1 L2 and black red white and green Connect the black L1 wire from the unit to the black L1 wire from the main power wall switch using a wire connector not supplied Connect the other end of the black L1 wire to the L1 terminal of the main power wall switch Connect the red L2 wire from the unit and the white Neutral wire from the unit to the white Neutral wire of the main power wall switch by using a wire connector not supplied 9 Connect the other end of the white Neutral wire to the white Neutral wire from the power supply panel by using a wire connector not supplied 10 Connect the green Ground wire from the unit to the green Ground wire of the main power wall switch by using a wire connector not supplied 11 Connect the black L1 wire from the power supply to the L1 terminal of the main power wall switch 12 Secure the 2 remaining green Ground wires with a ground screw in the main switch wall box 13 Ensure that all connections are tight 14 Insert all the wiring of the main power wall switc
4. TOP BYPASS HARNESS BROWN FROM TOP ORANGE FROM TOP LOWER HARNESS BROWN ORANGE RED CUT OUTLONG WIRE RED CUT OUT SHORT WIRE CUT OUT WY lt tc lt a 2 UPPER SECTION WIRING SCHEMATIC 1 888 DIMPLEX SC Dimplex 1 888 346 7539 C US 1367 Industrial Road Cambridge Ontario Canada N1R 7G8 Approved for use in the United States and Canada
5. X Dimplex INSTALLATION GUIDE FOR THE ELECTRIC FIREPLACE MODEL NUMBERS BF33ST DX BF39ST DX BF45ST DX CONTENTS PAGE 1 PAGE 1 PAGE 1 PAGE 2 PAGE 2 PAGE 2 PAGE 3 PAGE 3 PAGE 4 PAGE 5 PAGE 6 7 8 9 10 11 12 13 14 15 16 18 Listings and Code Approvals Model Specifications Step by Step Installation Section A Framing Section B Recommended Power Supply Wire Specifications Recommended Wire and Fusing Requirements Voltage Selector Switch Location Mounting Flanges Section C Factory Setting Wiring 240 Volt Without Main Power Wall Switch Factory Setting Wiring 120 volt Without Main Power Wall Switch Section D Main Power Wall Switch Wiring for 240 Volt Main Power Wall Switch Wiring for 120 Volt Section E Heater Wall Switch Wiring for 120 240 Volt Wall Mounted Thermostat Wiring for 120 240 Volt Flame Override Switch Wiring for 120 240 Volt Section F Wiring Diagrams LISTINGS AND CODE APPROVALS The BF series fireplaces have been tested in accordance with the UL 2021 and CSA 22 2 No 46 standards for fixed and location dedicated electric room heaters MODEL SPECIFICATIONS Model Number AMPS No Heat 120 Volt Option Option N A 2 0 Remote Wall Refractory Description Voltage Volts Rated Power Watts Control Th rmostat Brick Look 33 120 120 208 245 1440 2100 Standard 240 2700
6. d to the edge of the unit Four mounting flanges on the sides of the unit are provided to facilitate installation Insulation and vapor barrier should be placed a minimum of 2 inches from the unit SECTION B RECOMMENDED POWER SUPPLY WIRE SPECIFICATIONS For 120 volt installations use two conductor non metallic sheath cable with ground wire 3 wires total for the incoming power supply on fireplace inserts Use the appropriate wire to meet local and national electrical codes for rated power consumption For 208 240 volt installations use three conductor non metallic sheath cable with ground wire 4 wires total for the incoming power supply on fireplace inserts Use the appropriate wire to meet local and national electrical codes for rated power consumption Two conductor non metallic sheath cable with ground wire 3 wires total is recommended for installation of a wall mounted thermostat and or wall switch for use on fireplace inserts Use appropriate wire to meet local and national electrical codes for rated power consumption All wire gauges should match the recommended wire sizes shown below RECOMMENDED WIRE AND FUSING REQUIREMENTS VOLTS WIRE GAUGE FUSE RATING 120 VOLT 12 GAUGE 15 AMP 208 VOLT 12 GAUGE 15 AMP 240 VOLT 12 GAUGE 15 AMP VOLTAGE SELECTOR SWITCH LOCATION IMPORTANT Ensure that the incoming power supply voltage matches the setting of the voltage selector switch NOTE The voltage selec
7. een Ground wire from the main power wall switch by using a wire connector not supplied 12 Connect the red or black L1 wire from the power supply to the L1 terminal of the main power wall switch 13 Connect the black L2 wire from the power supply to the L2 terminal of the main power wall switch 14 Connect the white Neutral wire from the power supply to the remaining white Neutral wire from the unit by using a wire connector 15 Secure the 2 remaining green Ground wires with a ground screw in the main switch wall box 16 Ensure that all connections are tight 17 Insert all the wiring of the main power wall switch into the main switch wall box 18 Insert all the wiring back into the unit and secure with a cable clamp 240 VOLT MAIN WALL SWITCH WIRING DIAGRAM 240 POWER WALL SUPPLY BLACK L1 SWITCH C BREAKER PANEL x m z S z 5 2 lt oc LL MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NOTE This option should not be used with the remote control kit NOTE Before installing the unit have the following wires installed 1 2 conductor wire with ground 3 wires total from the power supply panel to the main switch wall box 2 2 conductor wire with ground 3 wires total from the main switch wall box to the junction box on the unit NOTE Use a single pole single throw on off wall switch that is rated for a minimum of 15 amps 120 VOLT INSTALLATI
8. g the unit to the power supply 120 VOLT INSTALLATION NO HEAT INSTALLATION 1 Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit see figure 2 on page 3 2 Flip the switch from 240 volt to 120 volt configuration 230 and 115 is printed on switch Loosen the screw securing the junction box cover and remove the cover Remove the knockouts if necessary or use the provided cable clamp Pull out the four wires marked L1 L2 N and G Connect the black L1 wire from the unit to the black L1 from the power supply Install a wire nut on the red L2 wire nut not included Connect the white N wire from the unit to the white neutral wire from the power supply Connect the green ground wire from the unit to the ground from the power supply 0 When the unit has been configured for the appropriate power supply voltage ensure that all connections are tight 11 Insert all the wiring back into the unit and secure with a cable clamp 3 4 5 6 7 8 9 4 WHITE WIRE WHITE WIRE RED WIRE 12 120 V POWER SUPPLY BREAKER PANEL FIREPLACE JUNCTION BOX SECTION D MAIN POWER WALL SWITCH WIRING OPTIONS MAIN POWER WALL SWITCH WIRING FOR 240 VOLT NOTE This option should not be used with the remote control kit NOTE Before installing the unit you must have the following wires installed 1 3 conductor wire with ground 4 wires total from the power
9. green Remove the wire connector and separate the wires marked 3 and 4 Connect the blue 3 wire from the unit to the black L1 wire from the flame override wall switch by using a wire connector not supplied Connect the other end of the black L1 wire from the flame override wall switch to the L1 terminal of the flame override wall switch Connect the blue 4 wire from the unit to the white Neutral wire from the flame override wall switch using a wire connector not supplied Connect the other end of the white Neutral wire from the flame override wall switch to the L2 terminal of the flame override wall switch Connect the green Ground wire from the unit to the green Ground wire from the flame override wall switch using a wire connector not supplied 10 Secure the one remaining green Ground wire with a ground screw in the flame override switch wall box 11 Ensure that all connections are tight 12 Insert all the wiring of the heater wall switch into the heater switch wall box 13 Insert all the wiring back into the unit and secure with a cable clamp FLAME OVERRIDE WALL SWITCH WIRING DIAGRAM FOR 120 240 VOLT SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION NOT AVAILABLE WITH NO HEAT INSTALLATION 3 WALL SWITCH LEE GROUND G x t z e E 2 2 LU fra Lu zz c E Oo lt Lu aw oc 8 5 a FLICKER MOTOR BLACK L1 RED FROM
10. h into the main switch wall box 15 Insert all the wiring back into the unit and secure with a cable clamp 120 VOLT MAIN WALL SWITCH WIRING DIAGRAM M POWER BREAKER WALL WHITE 120 V FIREPLACE JUNCTION BOX GROUND G A GROUND G MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NO HEAT INSTALLATION NOTE This option should not be used with the remote control kit NOTE Before installing the unit have the following wires installed 2 conductor wire with ground 3 wires total from the power supply panel to the main switch wall box 4 A2 conductor wire with ground 3 wires total from the main switch wall box to the junction box on the unit NOTE Use a single pole single throw on off wall switch that is rated for a minimum of 15 amps 120 VOLT INSTALLATIONS 16 Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit see figure 2 on page 3 17 Ensure that the switch is in the 120 volt position 115 is printed on switch 18 Loosen the screw securing the junction box cover and remove the cover 19 Remove the knockouts if necessary or use the provided cable clamp 20 Pull out the four wires marked L1 L2 N and G black red white and green 21 Connect the black L1 wire from the unit to the black L1 wire from the main power wall switch using a wire connector not supplied 22 Connect the othe
11. he framed opening level with shims if necessary and attach unit to frame using mounting flanges provided see figure 3 on page 3 Unit is factory wired for 208 240 volt power supply see figure 1 on page 3 If 120 volt operation is required slide the switch and reconfigure the wiring see figure 2 on page 3 Wires L1 L2 N amp G are attached to the rear of the junction box cable clamp for easy access Note If wiring unit to operate with NO heat a dedicated circuit may not be required Wire a dedicated properly fused circuit with a 15amp rating for the appropriate voltage 120 208 240 see Section C for factory setting wiring Make wall switch and or wall mounted thermostat connections as outlined in Section D Wiring Place all connectors inside the unit and secure the junction box cover to unit Ensure that the cable clamp grips only the jacket of service cable thermostat and if applicable wall switch lines WARNING Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner see diagram in Section A SECTION A FRAMING Dimensions MODEL BF33ST DX BF39ST DX BF45ST DX Top Surface Air Intake Slots Rough in framing dimensions Firebox dimensions Rough in corner framing This fireplace is a zero clearance design No combustibles can be placed on the top surface of the fireplace Combustibles may be installe
12. nel on the top right hand corner of the unit see figure 2 on page 3 2 Flip the switch from 240 volt to 120 volt configuration 230 and 115 is printed on switch 3 Loosen the screw securing the junction box cover and remove the cover 4 Remove the knockouts if necessary or use the provided cable clamp 5 Pull out the four wires marked L1 L2 N and G 6 7 Connect the black L1 wire from the unit to the black L1 from the power supply Connect the red L2 and white N wire from the unit to the white neutral wire from the power supply 8 Connect the green ground wire from the unit to the ground from the power supply 9 When the unit has been configured for the appropriate power supply voltage ensure that all connections are tight 10 Insert all the wiring back into the unit and secure with a cable clamp WHITE WIRE N WHITE WIRE N RED WIRE 2 120 V POWER SUPPLY BREAKER GREEN WIRE G GROUND WIRE G PANEL FIREPLACE JUNCTION BOX SECTION C FACTORY SETTING WIRING WITHOUT MAIN POWER WALL SWITCH NO HEAT INSTALLATION IMPORTANT The unit is factory configured for 208 240 volt operation NOTE Use 2 conductor wire with ground 3 wires total from the power supply breaker panel to the junction box on the unit NOTE All wiring must be completed prior to installing the unit NOTE Ensure that the voltage selector switch is in the proper position for the required supply voltage prior to connectin
13. page 3 2 Ensure that the switch is in the 240 volt position 230 is printed on switch Loosen the screw securing the junction box cover and remove the cover Remove the knockouts if necessary or use the provided cable clamp Pull out the four wires marked 11 12 and G Connect the red L2 wire from the unit to the red L2 from the power supply Connect the white N wire from the unit to the to the white neutral from the power supply 9 Connect the green ground wire from the unit to the ground from the power supply 10 Ensure that all connections are tight 11 Insert all the wiring back into the unit and secure with a cable clamp 3 4 5 6 Connectthe black L1 wire from the unit to the black L1 from the power supply 7 8 WHITE WIRE WHITE WIRE N POWER SUPPLY GREEN WIRE GROUND WIRE BREAKER PANEL FIREPLACE JUNCTION BOX SECTION C FACTORY SETTING WIRING WITHOUT MAIN POWER WALL SWITCH IMPORTANT The unit is factory configured for 208 240 volt operation NOTE Use 2 conductor wire with ground 3 wires total from the power supply breaker panel to the junction box on the unit NOTE All wiring must be completed prior to installing the unit NOTE Ensure that the voltage selector switch is in the proper position for the required supply voltage prior to connecting the unit to the power supply 120 VOLT INSTALLATION 1 Locate the voltage selector switch inside the exhaust pa
14. r end of the black L1 wire to the L1 terminal of the main power wall switch 23 Install a wire nut on the red L2 wire nut not included 24 Connect the white Neutral wire from the unit to the white Neutral wire of the main power wall switch by using a wire connector not supplied 25 Connect the other end of the white Neutral wire to the white Neutral wire from the power supply panel by using a wire connector not supplied 26 Connect the green Ground wire from the unit to the green Ground wire of the main power wall switch by using a wire connector not supplied 27 Connect the black L1 wire from the power supply to the L1 terminal of the main power wall switch 28 Secure the 2 remaining green Ground wires with a ground screw in the main switch wall box 29 Ensure that all connections are tight 30 Insert all the wiring of the main power wall switch into the main switch wall box 31 Insert all the wiring back into the unit and secure with a cable clamp 120 VOLT MAIN WALL SWITCH WIRING DIAGRAM NO HEAT INSTALLATION WHITE N 120 V POWER SUPPLY BREAKER PANEL SECTION E HEATER WALL SWITCH AND WALL THERMOSTAT WIRING OPTIONS HEATER WALL SWITCH WIRING FOR 120 240 VOLT NOTE Before installing the unit complete the following 1 Install main power connection with appropriate voltage as per Section C or Section D 2 Install a 2 conductor wire with ground 3 wires total from the heater swi
15. supply panel to the main switch wall box 2 3 conductor wire with ground 4 wires total from the main switch wall box to the junction box on the unit NOTE Use a double pole single throw on off wall switch that is rated for a minimum of 15 amps 240 VOLT INSTALLATIONS 1 Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit see figure 1 on page 3 2 Ensure that the switch is in the 240 volt position 230 is printed on switch 3 Loosen the screw securing the junction box cover and remove the cover 4 Remove the knockouts if necessary or use the provided cable clamp 5 Pull out the four wires marked L1 L2 N and G black red white and green 6 Connect the black L1 wire from the unit to the black L1 wire from the main power wall switch by using a wire connector not supplied Connect other end of black L1 wire from the main power wall switch to the L1 terminal of the main power wall switch 8 Connect the red L2 wire from the unit to the red L2 wire from the main power wall switch by using a wire connector not supplied 9 Connect the other end of the red L2 wire from the main power wall switch to the L2 terminal of the main power wall switch 10 Connect the white Neutral wire from the unit to the white Neutral wire from the main power wall switch by using a wire connector not supplied 11 Connect the green Ground wire from the unit to the gr
16. tch wall box to the junction box on the unit NOTE Use a heater wall switch on off that is rated for a minimum of 15 amps 120 240 VOLT INSTALLATIONS Loosen the screw securing the junction box cover and remove the cover Remove the knockouts if necessary or use the provided cable clamp Pull out the three wires marked 1 2 and G red red and green Remove the wire connector and separate the wires marked 1 and 2 Connect the red 1 wire from the unit to the black L1 wire from the heater wall switch by using a wire connector not supplied Connect the other end of black L1 wire from the heater wall switch to the L1 terminal of the heater wall switch Connect the red 2 wire from the unit to the white Neutral wire from the heater wall switch using a wire connector not supplied Connect the other end of the white Neutral wire from the heater wall switch to the L2 terminal of the heater wall switch Connect the green Ground wire from the unit to the green Ground wire from the heater wall switch using a wire connector not supplied 10 Secure the one remaining green Ground wire with a ground screw in the heater switch wall box 11 Ensure that all connections are tight 12 Insert all the wiring of the heater wall switch into the heater switch wall box 13 Insert all the wiring back into the unit and secure with a cable clamp HEATER WALL SWITCH WIRING DIAGRAM FOR 120 240 VOLT SEE SECTION C
17. the green ground wire from the unit to the green ground wire from the thermostat wall box by using a wire connector not supplied 10 Connect the other end of the green ground wire to the thermostat wall box ground screw 11 Ensure that all connections are tight 12 Insert all the wiring of the wall mounted thermostat into the wall box 13 Insert all the wiring back into the unit and secure with a cable clamp WALL MOUNTED THERMOSTAT WIRING DIAGRAM FOR 120 240 VOLT SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION CONNECT GROUND TO WALL BOX WALL THERMOSTAT GROUND G gt lt a 2 o 5 lt m n LLI oc FLAME OVERRIDE SWITCH WIRING FOR 120 240 VOLT NOT AVAILABLE WITH NO HEAT INSTALLATION NOTE The fireplace can be wired to have a wall switch operate the heater independent of the flame NOTE Before installing the unit complete the following 1 Install main power connection with appropriate voltage as per Section C or Section D 2 Install a 2 conductor wire with ground 3 wires total from the flame override switch wall box to the junction box on the unit NOTE Use a wall switch on off that is rated for a minimum of 15 amps 120 240 VOLT INSTALLATIONS Loosen the screw securing the junction box cover and remove the cover Remove the knockouts if necessary or use the provided cable clamp Pull out the three wires marked 3 4 and G blue blue and
18. tor switch is located inside the exhaust panel on the top right hand corner CAUTION When changing the voltage selector switch from 240 volts to 120 volts ensure that the power supply is turned FIGURE 1 off NOTE Carefully insert a flat headed screwdriver inside the exhaust panel to change the switch from 240 volts 230 position to 120 volts 115 position When wiring the unit for 208 240 volts the voltage selector switch should be in the 230 volt position see figure 1 When wiring the unit for 120 volts the voltage selector switch should be in the 115 volt position see figure 2 FIGURE 2 MOUNTING FLANGES There are two mounting flanges located on each side of the fireplace insert Bend tabs and mount to framing using suitable hardware Mounting Flanges FIGURE 3 SECTION C FACTORY SETTING WIRING WITHOUT MAIN POWER WALL SWITCH IMPORTANT The unit is factory configured for 208 240 volt operation NOTE Use 3 conductor wire with ground 4 wires total from the power supply breaker panel to the junction box on the unit NOTE All wiring must be completed prior to installing the unit NOTE Ensure that the voltage selector switch is in the proper position for the required supply voltage prior to connecting the unit to the power supply 240 VOLT INSTALLATION 1 Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit see figure 1 on