Home

Desa FVF18P User's Manual

image

Contents

1. If you cannot reach your gas supplier call the fire department IMPORTANT Operating heater where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new carpet or textiles etc create fumes These fumes may mix with combustion air and create odors These odors will disappear over time OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heater produces a clicking ticking noise just after burner is lit or shut off l Metal expanding while heating or con tracting while cooling 1 This is common with most heaters If noise is excessive contact qualified ser vice person Heater produces unwanted odors Heater burning vapors from paint hair spray glues cleaners chemicals new carpet etc see IMPORTANT statement above Gas leak See Warning statement at top of page Open window and ventilate room Stop using odor causing products while heater is running Locate and correct all leaks see Check ing Gas Connections page 13 Heater shuts off in use ODS operates Not enough fresh air is available Low line pressure ODS pilot is partially clogged Open window and or door for ventilation 2 Contact local natural gas company Clean ODS pilot see Cleaning and Maintenance page 20 Gas odor even when control knob is in OFF position Gas leak See Warning statement at top of page Control va
2. ry J pe fri UNVENTED VENT FREE PROPANE LP GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL ALSO DESIGN CERTIFIED AS A VENTED DECORATIVE APPLIANCE Heat Majic Models FVF18P FVF24P and FVF30P Patent Pending 18 24 and 30 Variable Manually Controlled Models WARNING ff the information in this manual is not followed exactly a fire or explosion may result causing property damage per sonal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire department Installation and service must be per formed by a qualified installer ser vice agency or the gas supplier WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installa tion and operational procedures For as sistance or additional information con sult a qualified installer service agency or the gas supplier WARNING This appliance is for installa tion only in a solid fuel burning masonry or UL127 factory built fireplace or in an approved vent
3. If you do not fol low these instructions exactly a fire or explosion may result caus ing property damage personal injury or loss of life This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un der water Ignitor Button al LIGHTING INSTRUCTIONS A WARNING e If fireplace has glass doors never operate this heater with glass doors closed If you op erate heater with doors closed heat buildup inside fireplace
4. Combustible Material 8 12 15 18 20 Min Top of Fireplace Opening HDABK HDABR TAA Mantel Figure 7 Minimum Mantel Clearances When Using Hood EO Q azi AT Hearth Combustible o oe Combustible 5 Material 2 Min ig Min Non Combustible Material Figure 8 Minimum Fireplace Clearances If Installed at Floor Level Figure 9 Minimum Fireplace Clearances Above Combustible Flooring Continued FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER INSTALLATION Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note When used as a vented heater appli ance must be installed only in a solid fuel burning fireplace with a working flue and constructed of non combustible material If your heater is a manually controlled model you may use this heater as a vented product There are three reasons for operating your heater in the vented mode 1 The fireplace does not meet the clear ance to combustibles requirements for vent free operation 2 State or local codes do not permit vent free operation 3 You prefer vented operation Ifreasons number or 2 above apply to you you must permanently open chimney flue damper You must install the damper clamp accessory to order see Accessories page 21 This will insure vented operation see Figure 10 The damper clamp will keep damper open Installation instructions are
5. Inlet Po Holes Shape of Holes May Vary by Model Figure 23 Injector Holder On Outlet Burner Tube Ports Slots Burner Tube Pilot Assembly Pilot Air Inlet Hole Figure 24 Pilot Inlet Air Hole 20 LOGS e If you remove logs for cleaning refer to Installing Logs page 14 to properly re place logs e Replace log s if broken or chipped dime sized or larger MAIN BURNER Periodically inspect all burner flame holes with the heater running All slotted burner flame holes should be open with yellow flame present All round burner flame holes should be open with a small blue flame present Some burner flame holes may be come blocked by debris or rust with no flame present If so turn off heater and let cool Either remove blockage or replace burner Blocked burner flame holes will create soot SERVICE HINTS When Gas Pressure Is Too Low e pilot will not stay lit e burners will have delayed ignition e heater will not produce specified heat e propane LP gas supply may be low When Gas Quality Is Bad e pilot will not stay lit e burners will produce flames and soot e heater will backfire when lit You may feel your gas pressure is too low or gas quality is bad If so contact your local propane LP gas supplier TECHNICAL SERVICE You may have further questions about in stallation operation or troubleshooting If so contact Fireplace Manufacturers Incorporated s Technical Servi
6. Keep control knob pressed in for five 5 seconds see Figure 19 Note You may be running this heater for the first time after hook ing up to gas supply If so the con trol knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system e If control knob does not pop out when released contact a qualified service person or gas supplier for repairs With control knob pressed in press and release ignitor button This will light pilot The pilot is attached to the burner If needed keep pressing ig nitor button until pilot lights Note If pilot does not light contact a qualified service person or gas sup plier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Light ing Procedure on page 16 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 Slightly depress and turn control knob counterclockwise N to the HIGH position The burner should light Set control knob to any heat level between HIGH and LO Thermocouple Pilot Burner Figure 20 Pilot Note Appearance of pilot assembly may vary by model Continued FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER OPERATING HEATER Continued i VARIABLE CONTROL OPERATION The variable control valve can be set to any heat setting and flame
7. all items for any shipping dam age If damaged promptly inform dealer where you bought heater PRODUCT FEATURES OPERATION This heater is clean burning It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by realistic dancing yellow flames This heater is designed for vent free operation with flue damper closed It has been tested and ap proved to ANS Z21 11 2 standard for unvented heaters State and local codes in some areas prohibit the use of vent free heaters This heater may also be operated as a vented decorative ANS Z21 60 product by opening the flue damper SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYSTEM This heater has a piezo ignitor This system requires no matches batteries or other sources to light heater FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER AIR FOR COMBUSTION AND VENTILATION AX WARNING This heater shall not be installed ina confined space or unusually tight construction unless provisions are provided foradequate combustion and ven tilation air Read the following in structions to insure proper fresh air for this and other fuel burning appliances in your home Today s homes are built more energy e
8. and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly A CAUTION Avoid damage to regulator Hold gas regulator with wrench when connecting itto gas piping and or fittings A G A Design Certified Manual Shutoff Valve With 1 8 NPT Tap Approved Flexible Gas Hose if allowed by local codes Gas Regulator Minimum inlet pressure for purpose of input adjustment 105192 INSTALLATION Continued CHECKING GAS CONNECTIONS Ay WARNING Test all gas pip ing and connections for leaks after installing or servicing Cor rect all leaks at once WARNING Never use an open 1 OWNER S MANUAL Test Pressures Equal Toor Less Than 1 2 PSIG Close manual shutoff valve see Fig ure 15 Pressure Testing Heater Gas Connections 1 Open manual shutoff valve see Fig ure 15 Open propane LP supply tank valve Make sure control knob of heater is in the OFF position Check all joints from manual shutoff valve to control valve see Figure 16 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once A CAUTION Make sure exter nal regulator has been installed between propane LP supply and heater See guidelines
9. codes Figure 11 Attaching Flexible Gas Hose to Heater Gas Regulator Masonry Screw Bracket with Screw Holes Figure 12 Attaching Base Assembly to Fireplace Floor Continued FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER INSTALLATION Continued CONNECTING TO GAS SUPPLY AX WARNING A qualified ser vice person must connect heater to gas supply Follow all local codes A CAUTION Never connect heater directly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator be tween the heater and propane LP supply Installation Items Needed Before installing heater make sure you have the items listed below e external regulator supplied by installer e piping check local codes e sealant resistant to propane LP gas e manual shutoff valve e test gauge connection e sediment trap e tee joint e pipe wrench AnA G A design certified manual shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection The installer must supply an external regu lator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 inches of water If you do not reduce incom ing gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 13 Pointing the vent down prot
10. flame is not touching the thermo couple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 22 e turn heater off see To Turn Off Gas to Appliance column 1 e see Troubleshooting pages 17 through 19 Pilot Burner Thermocouple Figure 21 Correct Pilot Flame Pattern Pilot Burner Figure 22 Incorrect Pilot Flame Pattern BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance These holes may become blocked with dust or lint Periodically inspect these holes for any blockage and clean if needed Blocked air holes will create soot MAIN BURNER Periodically inspect all burner flame holes with the heater running All slotted burner flame holes should be open with yellow flame present All round burner flame holes should be open with a small blue flame present Some burner flame holes may be come blocked by debris or rust with no flame present If so turn off heater and let cool Either remove blockage or replace burner Blocked burner flame holes will create soot 105192 TROUBLESHOOTING Note For additional help visit DESA International s Technical Service web site at www desatech com Note All troubleshooting items are listed in order of operation OBSERVED PROBLEM OWNER S MANUAL AX WARNING Turn off and un plu
11. gas e purchase date Usually we will ask you to return the defec tive part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Fireplace Manufacturers Incorporated s Parts Department at 1 800 888 2050 for referral information When calling Fireplace Manufacturers Incorpo rated have ready e model number of your heater e the replacement part number Heat Majic 18 Variable 24 30 Variable Manually Manually Controlled Controlled Btu Variable 16 000 27 000 16 000 31 500 Type Gas Propane LP Only Propane LP Only Ignition Piezo Piezo Pressure Manifold 8 0 W C 8 0 W C Inlet Gas Pressure in of water Maximum 14 14 Minimum 11 11 Shipping Weight 36 lbs 38 Ibs For input adjustment 105192 21 FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER ILLUSTRATED PARTS BREAKDOWN HEAT MAJIC FVF18P FVF24P FVF30P ODS Pilot co 22 105192 OWNER S MANUAL PA RTS LI ST This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 21 of this manual FVF18P FVF24P FVF30P 105192 KEY ONoOaRWBD FVF18P 105
12. height desired by simply turning the control knob until that setting is attained Even the lowest setting provides realistic dancing yellow flames Selecting higher settings produces greater heat output This results in in creased heating comfort A WARNING Do not operate heater between PILOT and HIGH positions A CAUTION Donottry to adjust heating levels by using the manual shutoff valve lee TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1 Press in and turn control knob clock wise to the HIGH position 2 Turn the control knob clockwise to the PILOT position 3 Press in control knob and turn clock wise N to the OFF Position Shutting Off Burners Only pilot stays lit 1 Turn the control knob clockwise 7 to the HIGH position 2 Pressin and turn control knob clock wise to the PILOT position i MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Light ing Instructions page 15 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Now follow step 8 page 15 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often PILOT FLAME PATTERN Figure 21 shows a correct pilot flame pat tern Figure 22 shows an incorrect pilot flame pattern Note Appearance of pilot assembly may vary by model The incor rect pilot
13. of fireplace opening a hood is not required see Figure 6 Determining Minimum Mantel Clearance When Using a Hood If minimum clearances in Figure 6 are not met you must have a hood When using a hood there are still certain minimum mantel clearances required Follow minimum clear ances shown in Figure 7 when using hood NOTICE If your installation does not meet the minimum clearances shown you must do one of the following operate the logs only with the flue damper open e raise the mantel to an accept able height remove the mantel FLOOR CLEARANCES A If installing appliance on the floor level you must maintain the minimum dis tance of 14 to combustibles see Fig ure 8 If combustible materials are less than 14 to the fireplace you must install appliance at least 5 above the com bustible flooring see Figure 9 105192 OWNER S MANUAL Mantel Shelf Underside of Mantel Shelf A All minimum distances are coer in inches Minimum Non gt A Cae Log Set ater 12 18 20 22 24 24 30 Models 8 8 14 163 4 20 18 Model Yy Top of Fireplace Uu Lu si J Opening Minimum Non Distances to Combustible Underside of Material Height Mantel Figure 6 Minimum Mantel Clearances Without Using Hood Mantel Shelf T Underside of Mantel Shelf A All minimum T distances are Minimum Non gt in inches
14. will cause glass to burst Also if fireplace opening has vents at the bottom you must open the vents before operating heater e You must operate this heater with afireplace screenin place Make sure fireplace screen is closed before running heater NOTICE During initial operation of new heater burning logs will give off a paper burning smell Open damper or window to vent smell This will only lasta few hours Note Home owners generally prefer to operate their heater with the chimney damper closed This will put all the heat into the room However there may be times you will desire the full flames of the High heat setting but will find the heat output excessive You can open the chim ney damper if you have one fully or partially to release some of the heat AX WARNING Damper handle will be hot if heater has been running 1 STOP Read the safety information column 1 2 Make sure manual shutoff valve is fully open 3 Press in and turn control knob clock wise AX to the OFF position 105192 Figure 19 Control Knob and Ignitor Button Location Te Ignitor Electrode Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation in column 1 If you don t smell gas go to the next step Slightly depress and turn control knob counterclockwise y N to the PILOT position
15. 186 01 098276 01 099553 01 102775 02CK 102844 01 102966 01 098867 10 102780 03 102798 01 099056 21 102843 01 102963 01 102568 08 098508 01 098354 01 102445 01 098249 01 099387 08 098271 07 099059 02 M11084 38 100563 01 101055 02 100565 01 100639 01 101449 04 101137 02 02016 FVF24P 105186 02 098276 01 099553 01 102775 01CK 102844 01 102966 01 098867 10 102780 03 102798 01 099056 19 102843 01 102773 01 102568 08 098508 01 098354 01 102445 01 098249 01 099387 08 098271 07 099059 02 M11084 38 100563 01 101055 02 100565 01 100639 01 101449 04 101137 02 02016 PART NUMBER FOR FVF30P 105186 03 098276 01 099553 01 102775 01CK 102844 01 102966 01 098867 10 102780 03 102798 01 099056 19 102843 01 102773 01 102568 08 098508 01 098354 01 102445 01 098249 01 099387 08 09827 1 07 099059 02 M11084 38 100863 01 101055 02 100565 01 100639 01 101449 04 101137 02 02016 23 DESCRIPTION One Piece Log Set Hex Head Plug 1 8 NPT Pilot Shield Painted Base Assembly Lower Bracket Upper Bracket Gas Regulator Outlet Burner Tube Inlet Tube Burner Orifice Injector Burner Clip Burner Control Valve Valve Retainer Nut Control Knob Piezo lIgnitor Nut M5 Pilot Tube Ignitor Cable ODS Pilot Screw Hex Head 8 18 x 38 PARTS AVAILABLE NOT SHOWN Warning Plate Lighting Instructions Plate Warning Plate Fastener Caution Decal Control
16. Burner does not light after ODS pilot is lit 1 Inlet gas pressure is too low 2 Burner orifice clogged 3 Burner orifice diameter is too small 1 Contact local natural gas company 2 Clean burner see Cleaning and Mainte nance page 20 or replace burner orifice 3 Replace burner orifice Delayed ignition burner 1 Manifold pressure is too low 2 Burner orifice clogged 1 Contact local propane LP gas company 2 Clean burner see Cleaning and Mainte nance page 20 or replace burner orifice Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective 1 Clean burner see Cleaning and Mainte nance page 20 or replace burner orifice 2 Replace damaged burner 3 Replace gas regulator Slight smoke or odor during initial operation 1 Not enough air 2 Gas regulator defective 3 Residues from manufacturing processes and logs curing 1 Check burner for dirt and debris If found clean burner see Cleaning and Maintenance page 20 2 Replace gas regulator 3 Problem will stop after a few hours of operation Heater produces a whistling noise when burner is lit 1 Turning control knob to HI position when burner is cold 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from
17. Have heater serviced Some people are more affected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Propane LP Gas Propane LP gas is odor less An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and understand all Warnings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any changeto this heater or its controls can be dangerous 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases 2 Donot place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors 10 11 To prevent performance problems the use of a propane LP tank of less than 100 lbs capacity is not recommended If you smell gas shut off gas supply e do not try to light any appliance do not touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions if you cannot reach your gas supplier call the fire department This heater shall not be installed in a bedroom or bathroom unless inst
18. Position Decal Hardware Kit Lava Rock 4 po Ss SB ae oe on om on on on on on in on on i e e WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No Date Purchased Always specify model and serial numbers when communicating with the factory We reserve the right to amend these specifications at any time without notice The only warranty applicable is our standard written warranty We make no other warranty expressed or implied LIMITED WARRANTY VENT FREE PROPANE GAS LOG HEATERS Fireplace Manufacturers Incorporated warrants this product to be free from defects in materials and components for four 4 years from the date of first purchase provided that the product has been properly installed operated and maintained in accordance with all applicable instructions To make a claim under this warranty the Bill of Sale or cancelled check must be presented This warranty is extended only to the original retail purchaser This warranty covers the cost of part s required to restore this heater to proper operating condition and an allowance for labor when provided by a Fireplace Manufacturers Incorporated Authorized Service Center Warranty part s MUST be obtained through authorized dealers of this product and or Fireplace Manufacturers Incorporated who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be i
19. This heater shall not be installed in a con fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are communicating only if there are doorless passageways or ventila tion grills between them 105192 OWNER S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height cu ft volume of space Example Space size 20 ft length x 16 ft width x 8 ft ceiling height 2560 cu ft volume of space If additional ventilation to adjoining room is supplied with grills or openings add the volume of these rooms to the total volume of the space 2 Divide the space volume by 50 cubic feet to determine the maximum Btu Hr the space can support volume of space 50 cu ft maximum Btu Hr the space can support Example 2560 cu ft volume of space 50 cu ft 51 2 or 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free heater Btu Hr Gas water heater Btu Hr Exampl
20. alled as a vented appliance see Installing Damper Clamp Accessory page 10 Never install the heater e in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the heater in high traffic areas in windy or drafty areas Before installing in a solid fuel burn ing fireplace the chimney flue and fire box must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage If damaged operate heater with flue damper closed If fireplace has glass doors never op erate this heater with glass doors closed If you operate heater with doors closed heat buildup inside fireplace will cause glass to burst Also if fireplace open ing has vents at the bottom you must open the vents before operating heater You must operate this heater with a fire place screen in place Make sure fireplace screen is closed before running heater This log heater is designed to be smoke less If logs ever appear to smoke turn off heater and call a qualified service person Note During initial operation slight smoking could occur due to log curing and heater burning manufactur ing residues To prevent the creation of soot follow the instructions in Cleaning and Main tenance page 20 12 Do not allow fans to blow directly into the fireplace Avoid any drafts
21. ately call a qualified service technician to in spect the room heater and to replace any part of the control system and any gas control which has been under water 22 Do not operate heater if any log is bro ken Do not operate heater if a log is chipped dime sized or larger 23 Turn heater off and let cool before ser vicing Only a qualified service person should service and repair heater 24 Operating heater above elevations of 4 500 feet could cause pilot outage 105192 PRODUCT IDENTIFICATION One Piece Log Set Piezo Ignitor Base Assembly we Control Knob Figure 1 Heat Majic Log Set LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANS Z223 1 alsoknownas NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 105192 OWNER S MANUAL Burner UNPACKING A CAUTION Do not remove the metal Data Plates from the grate assembly The Data Plates contain important product information 1 Remove logs and heater base assem bly from carton Note Do not pick up heater base assembly by the burner This could damage heater Always handle base assembly by grate 2 Remove all protective packaging ap plied to logs and heater for shipment 3 Check
22. ce Depart ment at 1 888 427 8322 You can also visit DESA International s Technical Service web site at www desatech com 105192 ACCESSORIES Purchase these heater accessories from your local dealer If they can not supply these accessories call Fireplace Manufacturers Incorporated s Parts Department at 1 800 888 2050 for referral information You can also write to the address listed on the back page of this manual FIREPLACE HOOD BLACK HDABK Part 01244 BRASS HDABR Part 01245 For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to 49 wide DAMPER CLAMP 02017 Not Shown Permanently opens chimney flue damper for vented operation LAVA ROCK 02016 Not Shown For all models Order when additional rock is desired 3 lb bag SPECIFICATIONS Heat Majic OWNER S MANUAL REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this prod uct If they can t supply original replace ment part s call Fireplace Manufactur ers Incorporated s Technical Service De partment at 1 888 427 8322 When call ing Fireplace Manufacturers Incorporated have ready e your name and address e model and serial numbers of your heater e how heater was malfunctioning e type of gas used propane LP or natural
23. chimney flue and firebox must be cleaned of soot creosote ashes and loose paint by a quali fied chimney cleaner Creosote will ignite if highly heated A dirty chimney flue may create and dis tribute soot within the house In spect chimney flue for damage If damaged operate heater with flue damper closed A WARNING Seal any fresh air vents or ash clean out doors lo cated on floor or wall of fireplace If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper 105192 OWNER S MANUAL AX WARNING Never install the heater inabedroom or bathroom un less installed as a vented ap pliance see page 10 e in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the heater e in high traffic areas in windy or drafty areas A CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add mois ture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moistur
24. e Gas furnace SS Buhr Gas water heater 40 000 Btu Hr Vented gas heater ____ Btw Hrr Vent free heater 31 500 Btw Hr Gas fireplace logs Btu Hr Total 71 500 Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu Hr maximum the space can support Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 71 500 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space because the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoin ing room or add ventilation grills between rooms See Ventilation Air From Inside Building page 6 B Vent room directly to the outdoors See Ventilation Air From Outdoors page 6 C Install a lower Btu Hr heater if lower Btu Hr size makes room unconfined If the actual Btu Hr used is less than the maximum Btu Hr the space can support the space is an unconfined space You will need no additional fresh air ventilation A WARNING If the area in which the heater may be operated is smaller than that defi
25. e See Air for Com bustion and Ventilation pages 4 through 6 CHECK GAS TYPE Use only propane LP gas If your gas supply is not propane LP do not install heater Call dealer where you bought heater for proper type heater INSTALLATION AND CLEARANCES Vent Free Operation Only AX WARNING Maintain the mini mum clearances If you can pro vide greater clearances from floor ceiling and adjoining wall MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size Side Wall Ceiling 18 24 16 42 and 30 LOG SIZING REQUIREMENTS Log Minimum Firebox Size Height Depth Front Rear Width Width 18 17 14 24 20 24 17 14 28 21 30 17 14 34 24 Measured at 14 depth Carefully follow the instructions below This will ensure safe installation into a masonry factory built UL127 listed manufactured fireplace or listed vent free firebox Minimum Wall and Ceiling Clearances see Figure 4 A Clearances from the side of the fire place opening to any combustible wall should not be less than 16 inches B Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches Left and Right Sides po Figure 4 Minimum Clearance to Walland Ceiling Continued FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER INSTALLATION Continued NOTICE Manua
26. e attics and crawl spaces IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Ventilation Grills Into Adjoining Room Option 1 Or Remove Door into Adjoining Room Option O 3 Ventilation Grills Into Adjoining Room Option 2 sa eR Figure 2 Ventilation Air from Inside Building EEEN Ventilated Attic Outlet Air J Inlet Air H To Attic E To wl ce Cra Inlet Air Ventilated Crawl Space Figure 3 Ventilation Air from Outdoors 105192 INSTALLATION NOTICE This heater is intended for use as supplemental heat Use this heater along with your pri mary heating system Do not in stall this heater as your primary heat source If you have a central heating system you may run system s circulating blower while using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heat source NOTICE State or local codes may only allow operation of this appli ance in a vented configuration Check your state or local codes Ay WARNING A qualified ser vice person must install heater Follow all local codes A WARNING Before installing in a solid fuel burning fireplace the
27. ecking Gas Joints Continued FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER INSTALLATION Continued INSTALLING LOGS WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury A CAUTION After installation and periodically thereafter check to ensure that no flame comes in contact with any log With the heater set to High check to see if flames contact any log If so re position logs according to the log installation instructions inthis manual Flames contacting logs will create soot Itis very important to install the logs exactly as instructed Do not modify logs Only use logs supplied with heater 1 Place one piece log set on grate to fit as illustrated in Figure 17 Make sure bottom of front log is in front of U shaped cutout in center of chassis see Figure 17 IMPORTANT Make sure log does not cover any burner ports 2 Place lava rock on fireplace floor around base of heater One Piece Se ahi Chassis U shaped Cutout in Chassis Figure 17 Installing Heat Majic One Piece Log Set Burner One Piece ports Log Set Figure 18 Installing Heat Majic One Piece Log Set Top View 105192 OPERATING HEATER OWNER S MANUAL FOR YOUR SAFETY READ BEFORE LIGHTING A WARNING
28. ects it from freezing rain or sleet External Regulator Propane LP Supply Tank ayes iy VR a ee ae Vent Pointing Down Figure 13 External Regulator With Vent Pointing Down A WARNING Never connect heater to private non utility gas wells This gas is commonly known as wellhead gas A CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur From External Regulator 11 W C to 14 W C Pressure a Tee Joint Pipe Nipple Cap Sediment Trap Figure 14 Gas Connection Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 14 Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use pipejoint seal ant that is resistant to liquid pe troleum LP gas Install sediment trap in supply line as shown in Figure 14 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap where trapped matter is not likely to freeze A sediment trap traps moisture
29. ere a walls and ceilings exposed to the outside atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 kg per pa sec m or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames be tween sole plates and floors be tween wall ceiling joints be tween wall panels at penetra tions for plumbing electrical and gas lines and at other openings If your home meets all of the three criteria above you must provide ad ditional fresh air See Ventilation Air From Outdoors page 6 If your home does not meet all of the three criteria above proceed to De termining Fresh Air Flow For Heater Location page 5 Confined and Unconfined Space The National Fuel Gas Code ANS 2223 1 1992 Section 5 3 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are in stalled through openings not furnished with doors are considered a part of the unconfined space
30. fficient than ever New materials increased insulation and new construction methods helpreduce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper com bustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from the house to operate You must provide ad equate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code NFPA 54 ANS Z223 1 Sec tion 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Confined Space The information on pages 4 through 6 will help you classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and win dows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction wh
31. g heater and let cool before servicing Only a qualified ser vice person should service and repair heater POSSIBLE CAUSE A CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot unit REMEDY When ignitor button is pressed there is no spark at ODS pilot 1 2 Dnue Ignitor electrode not connected to igni tor cable Ignitor cable pinched or wet Piezo ignitor nut is loose Broken ignitor cable Bad piezo ignitor Ignitor electrode positioned wrong Ignitor electrode broken 1 Reconnect ignitor cable Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel Replace ignitor cable Replace piezo ignitor Replace ignitor Replace ignitor When ignitor button is pressed there is spark at ODS pilot but no ignition p W NN Gas supply turned off or manual shutoff valve closed Control knob not in PILOT position Control knob not pressed in while in PILOT position Air in gas lines when installed Depleted gas supply ODS pilot is clogged Gas regulator setting is not correct Turn on gas supply or open manual shutoff valve Turn control knob to PILOT position Press in control knob while in PILOT position Continue holding down control knob Repeat igniting ope
32. included with clamp accessory Damper See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue opening will be maintained at all times Chimney Minimum Permanent Height ft Flue Opening sq ins 6 to 15 39 sq inches 15 to 30 29 sq inches A WARNING If installing in a sunken fireplace special care is needed You must raise the fire place floor to allow access to heater control panel This will in sure adequate air flow and guard against sooting Raise fireplace floor with noncombustible mate rial Make sure material is secure Area of Various Standard Round Flues Diameter ins Area Sq ins 5 20 sq inches 6 29 sq inches is 39 sq inches 8 51 sq inches INSTALLING HEATER BASE ASSEMBLY A WARNING You must secure this heater to fireplace floor If not heater will move when you adjust controls Moving heater may cause a gas leak Masonry Fireplace Figure 10 Attaching Damper Clamp Manufactured Fireplace A CAUTION Do not pick up heater base assembly by the burner This could damage heater Only handle base assem bly by grates A CAUTION Do not remove the metal data plates attached to the heater base assembly The data plates contain important warranty information IMPORTANT Make sure the heater burner is level If heater is not level hea
33. l control heaters may be used as a vented product If so you must always run heater with chimney flue damper open If running heater with damper open noncombustible material above fireplace opening is not needed Go to Installing Damper Clamp Accessory for Vented Op eration page 10 Minimum Noncombustible Material Clearances If Not Using Mantel Note If using a mantel proceed to Jf Using Mantel If not using a mantel follow the information below You must have noncombustible material s above the fireplace opening Noncombus tible materials such as slate marble tile etc must be at least 1 2 inch thick With sheet metal you must have noncombustible material behind it Noncombustible mate rial must extend at least 8 up for all mod els If noncombustible material is less than 12 you must install the fireplace hood accessory 24 and 30 models only See Figure 5 for minimum clearances IMPORTANT If you cannot meet these minimum clearances you must operate heater with chimney flue damper open Go to Installing Damper Clamp Accessory for Vented Operation page 10 If Using Mantel You must have noncombustible material s above the fireplace opening Noncombus tible materials such as slate marble tile etc must be at least 1 2 inch thick With sheet metal you must have noncombustible material behind it Noncombustible mate rial must extend at least 8 inches up for all models If noncomb
34. less firebox It is design certified for these installations in accor dance with ANS Z21 11 2 Exception Do not install this appliance in a factory built fireplace that includes instructions stat ing it has not been tested or should not be used with unvented gas logs WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilationsection on page 4 of this manual This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by state or local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer Save this manual for future reference FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER SAFETY INFORMATION A WARNINGS IMPORTANT Read this owner s manual carefully and completely before trying to assemble oper ate or service this heater Im proper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning AX DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning re semble the flu with headaches dizziness or nausea If you have these signs the heater may not be working properly Get fresh air at once
35. line Have gas line checked by local natural gas company 3 Observe minimum installation clear ances see pages 7 through 9 4 Clean burners see Cleaning and Mainte nance page 20 or replace burner orifice White powder residue forming within burner box or on adjacent walls or furniture 1 When heated vapors from furniture pol ish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaners or similar products Moisture condensation noticed on windows 1 Not enough combustion ventilation air 1 Refer to Air for Combustion and Venti lation requirements pages 4 through 6 Dark residue on logs or inside or fireplace 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked www desatech com 18 1 Properly locate logs see Installing Logs page 14 2 Eliminate source of drafts around heater 3 Clean out air holes at burner inlet Peri odically repeat as needed 4 Remove blockage or replace burner 105192 TROUBLESHOOTING Continued OWNER S MANUAL building A WARNING If you smell gas e Shut off gas supply Do nottry to light any appliance e Do not touch any electrical switch do not use any phone in your e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions
36. lve defective Locate and correct all leaks see Check ing Gas Connections page 13 Replace control valve Gas odor during combustion 105192 Foreign matter between control valve and burner Gas leak See Warning statement at top of page www desatech com 19 Take apart gas tubing and remove for eign matter Locate and correct all leaks see Check ing Gas Connections page 13 FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER CLEANING AND MAINTENANCE WARNING Turn off heater and let cool before cleaning A CAUTION You must keep control areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a quali fied service person Heater may need more frequent cleaning due to excessive lint from carpeting pet hair bedding material etc CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt and lint Clean these air inlet holes prior to each heating season Blocked air holes will create soot We rec ommend that you clean the unit every 2 500 hours of operation or every three months We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these part
37. ned as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code ANS 2223 1 1992 Section 5 3 or applicable local codes Continued 105192 5 FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options and 2 Figure 2 You can also remove door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts AX WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces includ
38. nstalled by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR 4 YEARS ON ALL COMPONENTS AND FROM THE DATE OF FIRST PURCHASE AND FIREPLACE MANUFACTURERS INCORPORATED S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND FIREPLACE MANUFACTURERS INCORPORATED SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you This warranty gives you specific legal rights and you may also have
39. other rights that vary from state to state For information about this warranty write Y Fireplace Q Manufacturers Ll Incorporated Me Syl Eacan 2701 South Harbor Boulevard Santa Ana CA 92704 www desatech com I l l 105192 01 105192 01 Rev B NOT A UPC 04 99
40. ration until air is re moved Contact local propane LP gas company Clean ODS pilot see Cleaning and Maintenance page 20 or replace ODS pilot assembly Replace gas regulator ODS pilot lights but flame goes out when control knob is released 105192 Nn on Control knob not fully pressed in Control knob not pressed in long enough Safety interlock system has been triggered Manual shutoff valve not fully open Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot Thermocouple connection loose at con trol valve Thermocouple damaged Control valve damaged www desatech com 17 Press in control knob fully 2 After ODS pilot lights keep control on knob pressed in 30 seconds Wait one minute for safety interlock sys tem to reset Repeat ignition operation Fully open manual shutoff valve A Contact local propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 20 or replace ODS pilot assembly Hand tighten until snug then tighten 1 4 turn more Replace thermocouple Replace control valve Continued FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE LP GAS LOG HEATER TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY
41. s we recom mend using compressed air no greater than 30 PSI Your local computer store hard ware store or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you don t follow direc tions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 23 3 Blow air through the ports slots and holes in the burner 4 Check the injector holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hairs with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 Incase any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Injector Holder May Be Brass Burner or Aluminum Tube i Depending on Model Primary Air
42. ter will not work properly 105192 INSTALLATION Continued Installation Items Needed 10 11 12 hardware package provided with heater approved flexible gas hose not provided if allowed by local codes sealant resistant to propane LP gas not provided electric drill with 3 16 drill bit metal or masonry as applicable flathead screwdriver Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator Connect approved flex ible gas hose to gas regulator of heater see Figure 11 IMPORTANT Hold gas regulator with wrench when connecting flexible gas hose Locate two masonry screws in hard ware package Place heater base in fireplace Place logs in their proper position on heater base Center heater base and logs front to back and side to side in fireplace Carefully remove logs without moving heater base Mark screw locations through one hole on each side of the mounting bracket see Figure 12 If installing in a brick bottom fireplace mark screw locations in mortar joint of bricks Remove heater base from fireplace Drill holes at marked locations using 3 16 drill bit Attach base assembly to fireplace floor using two masonry screws in hardware package Connect to gas supply See Connect ing To Gas Supply page 12 Replace logs on heater base 105192 OWNER S MANUAL Heater Gas Regulator Flexible Gas Hose if allowed by local
43. that al ter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting 13 Before using furniture polish wax car pet cleaner or similar products turn heater off If heated the vapors from these products may create a white pow der residue within burner box or on adjacent walls or furniture 14 Do not use a blower insert heat ex changer insert or other accessory not approved for use with this heater 15 This heater needs fresh outside air ven tilation to run properly This heater has an oxygen depletion sensor ODS pi lot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 If heater keeps shutting off see Trouble shooting pages 17 through 19 16 Do not run heater e where flammable liquids or vapors are used or stored e under dusty conditions 17 Do not use this heater to cook food or burn paper or other objects 18 Never place any objects on the heater 19 Heater base assembly becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shutdown Allow surface to cool before touching 20 Carefully supervise young children when they are in the room with heater 21 Do not use heater if any part has been exposed to or under water Immedi
44. under Con necting to Gas Supply page 12 Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 1 Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3 Pressurize supply piping system by ei ther using compressed air or opening propane LP supply tank valve 4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all leaks at once 6 Reconnect heater and manual shutoff valve to gas supply Check reconnected fittings for leaks 105192 2 Pressurize supply piping system by ei ther using compressed air or opening propane LP supply tank valve 3 Check all joints from propane LP sup ply tank to manual shutoff valve see Figure 16 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks at once Manual Shutoff Open Valve 5 Correct all leaks at once 6 Light heater see Operating Heater pages 15 and 16 Check all other in ternal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 16 Closed Figure 15 Manual Shutoff Valve Manual Control Valve Shutoff Location Propane LP Valve Supply Tank Figure 16 Ch
45. ustible material is less than 12 you must install the fireplace hood accessory 24 and 30 models only Even if noncombustible material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 5 and Figures 6 and 7 page 9 for minimum clearances IMPORTANT If you cannot meet these minimum clearances you must operate heater with chimney flue damper open Go to Installing Damper Clamp Accessory for Vented Operation page 10 Noncombustible Material Distance A Requirements for Safe Installation 12 or more Between 8 and 12 Less than 8 Noncombustible material OK 24 or 30 Models Install fireplace hood accessory HDABK or HDABR see Accessories page 21 18 Model Noncombustible material OK Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot extend material you must operate heater with flue damper open Heat Resistant Material Figure 5 Heat Resistant Material Slate Marble Tile etc Above Fireplace 105192 INSTALLATION Continued MANTEL CLEARANCES In addition to meeting noncombustible mate rial clearances you must also meet required clearances between fireplace opening and mantel shelf If you do not meet the clear ances listed below you will need a hood Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top