Home
Dell PowerEdge M1000E Setup Guide
Contents
1. NOM Importer Dell Inc de M xico S A de C V Paseo de la Reforma 2620 11 Piso Col Lomas Altas 11950 M xico D F Model number BMX01 Supply voltage 100 V CA to 240 V CA or 48 60 V DC Frequency 50 Hz 60 Hz or N A Current consumption 16 A x6 or 75 A x6 Model number FHB Supply voltage 12V DC Current consumption 75A Model number HHB Supply voltage 12V DC Current consumption 37A Model number QHB Supply voltage 12V DC Current consumption 35 A Technical Specifications K NOTE For additional specifications see your system Owner s Manual Power Blades Coin cell battery Power Enclosure AC DC power supply per power supply module Wattage Connector Heat dissipation Maximum inrush current System Voltage Requirements K NOTE This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V DC DC power supply per power supply module Wattage Connector Heat dissipation Maximum inrush current System Voltage Requirements NOTE Heat dissipation is calculated using the power supply wattage rating Physical Blades PowerEdge M915 Height Width Depth Weight maximum PowerEdge M910 Height Width Depth Weight maximum 3 V CR2032 Lithium coin cell 2360 W and 2700 W IEC C20 1205 BTU hr maximum Under typical line conditions and over the entire system ambient operating range the inrush curr
2. components To ensure protection for the electronic components inside follow the Electrostatic Discharge ESD guidelines Figure 2 Installing a Sleeve NOTE Before you install or remove a sleeve from the enclosure ensure that the top slot of the sleeve Blade a is empty You can install a blade in the top slot Blade a after you install the sleeve in the enclosure Remove the orange cover from the sleeve handle Slide the sleeve into the enclosure and lift the sleeve handle to the top position to secure the sleeve in the enclosure NOTE To ensure optimal thermal performance do not replace the cover on the sleeve handle after the sleeve is installed in the enclosure Reinstall the cover only if the sleeve is not installed in the enclosure Installing A Quarter Height Blade In A Sleeve A CAUTION Install a blade blank in all empty blade slots to maintain proper thermal conditions Slide the blade into the sleeve and rotate the blade handle upward to secure the blade in the sleeve Figure 3 Installing a Quarter Height Blade Installing A Full Or Half Height Blade A CAUTION Install a blade blank in all empty blade slots to maintain proper thermal conditions Figure 4 Installing a Half Height Blade NOTE The above figure shows installation of a half height blade The procedure for installing a full height blade is identical to installing a half height blade Beginning at the top slide the blades into the enclosur
3. 2 6 ms Six consecutively executed shock pulses in the positive and negative x y and z axes one pulse on each side of the system of 71 G for up to 2 ms 15 2 m to 3048 m 50 ft to 10 000 ft 11 Environmental Storage Airborne contaminant level Class NOTE For altitudes above 2950 ft the maximum operating temperature is derated 1 F per 550 ft 15 2 m to 10 668 m 50 ft to 35 000 ft G1 as defined by ISA S71 04 1985
4. 6 inch 5 cm 2 inch 44 3 cm 17 4 inch 3 kg 6 61 Ib 9 75 cm 3 8 inch 5 cm 2 inch 45 8 cm 18 inch Physical Blades Weight maximum 2 3 kg 5 07 Ib Physical Enclosure Height Width Depth Weight maximum Weight empty Environmental 44 0 cm 17 3 inch 44 7 cm 17 6 inch 75 5 cm 29 7 inch 200 5 kg 442 Ib 44 6 kg 98 1 Ib NOTE For additional information about environmental measurements for specific system configurations see dell com environmental_datasheets Temperature Operating Storage Relative humidity Operating Storage Maximum vibration Operating Storage Maximum shock Operating Storage Altitude Operating Continuous operation 10 C to 35 C at 10 to 80 relative humidity RH with 26 C max dew point De rate maximum allowable dry bulb temperature at 1 C per 300 m 1 F per 550 ft above 900 m 2952 75 ft NOTE For information on supported expanded operating temperature range and configurations see support dell com manuals 40 C to 65 C 40 F to 149 F with a maximum temperature gradation of 20 C per hour 10 to 80 relative humidity RH with 26 C max dew point 5 to 95 noncondensing at a maximum wet bulb temperature of 38 C 100 4 F 0 26 Gms at 5 Hz to 350 Hz for 15 min 1 54 G ms at 10 Hz to 250 Hz for 15 min One shock pulse in the positive z axis one pulse on each side of the system of 31 G for up to
5. Dell PowerEdge M1000e M915 M910 M820 M710HD M710 M620 M610x M610 M520 and M420 Getting Started Guide EA f gulat sade del BMX01 ol HHB Au naana gulatory Type DWHH H Ser s HHB Series FHB Series and QHB Fios Notes Cautions and Warnings K NOTE A NOTE indicates important information that helps you make better use of your computer CAUTION A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem A WARNING A WARNING indicates a potential for property damage personal injury or death 2012 Dell Inc Trademarks used in this text Dell the Dell logo Dell Precision OptiPlex Latitude PowerEdge PowerVault PowerConnect OpenManage EqualLogic Compellent KACE FlexAddress Force10 and Vostro are trademarks of Dell Inc Intel Pentium Xeon Core and Celeron are registered trademarks of Intel Corporation in the U S and other countries AMD is a registered trademark and AMD Opteron AMD Phenom and AMD Sempron are trademarks of Advanced Micro Devices Inc Microsoft Windows Windows Server Internet Explorer MS DOS Windows Vista and Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat Inc in the United States and or oth
6. e from left to right When the blade is securely installed the blade handle returns to the closed position Connecting The CMC And iKVM Modules Figure 5 Connecting the Modules Connect the serial cable and network cable s from the management system to the CMC module If a second optional CMC module is installed connect it as well Connect the keyboard mouse and monitor to the optional iKVM module Connecting The System To Power Figure 6 Connecting Power to the System Connect the system s power cables to the system power supplies CAUTION To prevent the power cables from being disconnected accidentally use the plastic clip on each power supply to secure the power cable to the power supply and use the strap to secure the power cable to the strain relief bar A CAUTION For AC power supply do not plug the power cables directly into a power outlet you must use a PDU For optimal system functionality a minimum of three power supplies are required Plug the other end of the power cables of the AC power supplies into a power distribution unit PDU For DC power supplies plug the other end of the power cables to a branch protected DC power source K NOTE The power supply units must have the same maximum output power K NOTE AC and DC power supplies cannot be mixed in an enclosure Turning On The Enclosure Figure 7 Enclosure Power Button Press the power button on the enclosure The power indicat
7. ent may reach 55 A per power supply for 10 ms or less 43 A 200 V AC to 240 V AC 50 Hz 60 Hz 2360 W power supply 16 A 100 V AC to 240 V AC 50 Hz 60 Hz 2700 W power supply 2700 W Molex 394260002 at PSU end mating connector Molex 39422 0012 1205 BTU hr maximum Under typical input voltage conditions and over the entire system ambient operating range the inrush current may reach 120 A per power supply for 10 ms or less 75 A 48 V DC to 60 V DC 38 5 cm 15 2 inch 5 cm 2 inch 48 6 cm 19 2 inch 12 7 kg 28 Ib 38 5 cm 15 2 inch 5 cm 2 inch 48 6 cm 19 2 inch 13 1 kg 29 Ib Physical Blades PowerEdge M820 Height Width Depth Weight maximum PowerEdge M710 and M610x Height Width Depth Weight maximum PowerEdge M710HD and M620 Height Width Depth Weight maximum PowerEdge M610 Height Width Depth Weight maximum PowerEdge M520 Height Width Depth Weight maximum PowerEdge M420 Sleeve Height Width Depth Weight Blade Height Width Depth 38 5 cm 15 2 inch 5 cm 2 inch 48 6 cm 19 2 inch 14 5 kg 31 9 Ib 38 5 cm 15 2 inch 5 cm 2 inch 48 6 cm 19 2 inch 11 1 kg 24 5 Ib 18 9 cm 7 4 inch 5 cm 2 inch 48 6 cm 19 2 inch 7 4 kg 16 3 Ib 18 9 cm 7 4 inch 5 cm 2 inch 48 6 cm 19 2 inch 5 2 kg to 6 4 kg 11 5 Ib to 14 0 Ib 18 9 cm 7 4 inch 5 cm 2 inch 48 6 cm 19 2 inch 6 4 kg 14 1 Ib 39 5 cm 15
8. er countries Novell and SUSE are registered trademarks of Novell Inc in the United States and other countries Oracle is a registered trademark of Oracle Corporation and or its affiliates Citrix Xen XenServer and XenMotion are either registered trademarks or trademarks of Citrix Systems Inc in the United States and or other countries VMware Virtual SMP vMotion vCenter and vSphere are registered trademarks or trademarks of VMware Inc in the United States or other countries IBM is a registered trademark of International Business Machines Corporation 2012 06 Rev A00 Installation And Configuration A WARNING Before performing the following procedure review the safety instructions that came with the blade server or enclosure Unpacking The System Unpack your blade server or enclosure and identify each item Installing The Rails And Enclosure Figure 1 Installing the Enclosure in the Rack Assemble the rails and install the enclosure in the rack following the safety instructions and the rack installation instructions provided with the enclosure Installing A Sleeve In The Enclosure K NOTE This procedure applies only to PowerEdge M420 A sleeve includes up to four quarter height blades to function as a system Depending on your order the sleeve may ship with the blades preinstalled A CAUTION Exercise utmost care when installing or removing the sleeve to prevent damage to the internal
9. or should light Turning On The Blades Figure 8 Turning on a Blade Press the power button on each blade or power on the blades using the systems management software Complete The Operating System Setup If you purchased a preinstalled operating system see the documentation associated with the operating system To install an operating system for the first time see the installation and configuration documentation for your operating system Be sure the operating system is installed before installing hardware or software not purchased with the system K NOTE See dell com ossupport for the latest information on supported operating systems Dell Software License Agreement Before using your system read the Dell Software License Agreement that came with your system You must consider any media of Dell installed software as BACKUP copies of the software installed on your system s hard drive If you do not accept the terms of the agreement call the customer assistance telephone number For customers in the United States call 800 WWWW DELL 800 999 3355 For customers outside the United States visit support dell com and select your country or region from the bottom of the page Other Information You May Need WARNING See the safety and regulatory information that shipped with your system Warranty information may be included within this document or as a separate document e The Owner s Manual provides information about system feature
10. s and describes how to troubleshoot the system and install or replace system components This document is available online at support dell com manuals e For the Owner s Manuals and Installation Guides for Dell EqualLogic hardware go to support equallogic com e The rack documentation included with your rack solution describes how to install your system into a rack if required e Any media that ships with your system that provides documentation and tools for configuring and managing your system including those pertaining to the operating system system management software system updates and system components that you purchased with your system K NOTE Always check for updates on support dell com manuals and read the updates first because they often supersede information in other documents K NOTE When upgrading your system it is recommended that you download and install the latest BIOS drivers and systems management firmware on your system from support dell com Obtaining Technical Assistance If you do not understand a procedure in this guide or if the system does not perform as expected see your Owner s Manual Dell offers comprehensive hardware training and certification See dell com training for more information This service may not be offered in all locations NOM Information The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards
Download Pdf Manuals
Related Search
Related Contents
GP50 Gradient Pump Operator`s Manual 取扱説明書・追補V2.11 「ファームウェアV2.11の新機能追加」 "user manual" ダウンロード User Manual - Chris Athanas CycloAgent v2 Manual del usuario transmissões eaton / clark - Otto Sistemas Hidráulicos 12" WOOD / METAL BAND SAW Saisons culturelles 2011-2012 (pdf 5,5Mo) Copyright © All rights reserved.
Failed to retrieve file