1. reference manual for information on setting the IP address for the switch 8 Fixed Rack Mount Kit Installation Procedure 53 1001792 01 1 Bracket front right 7 Screw 10 32 x 5 8 in panhead Phillips 4 Bracket rear right 8 Retainer nut 10 32 FIGURE 5 Attach the rear bracket to the cabinet rail Fixed Rack Mount kit Installation Procedure 53 1001792 01 10 Fixed Rack Mount Kit Installation Procedure 53 1001792 01
2. are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell Inc disclaims any proprietary interest in trademarks and trade names other than its own Regulatory Model Codes Brocade DCX 4S Brocade DCX 2 Fixed Rack Mount kit Installation Procedure 53 1001792 01 In this guide e roU arca Ilarda tire reale 3 installation requirements iii RTRT IRE TE RIA 3 e Tool requirements and parts list c cee eee 4 Saato POCEN E siriani ii er 5 Introduction This document provides instructions to install a 1U 1 5U or 2U switch or SAN Router in a 19 in 48 3 cm EIA cabinet using the Fixed Rack Mount Kit The supported switches are listed in Table 1 The switch can be installed so that the port side is either flush with the front rails or recessed from the front rails A recessed position allows a more gradual bend in the fiber optic cables connected to the switch TABLE 1 Supported switches Switch Height Switch Model 1U PowerConnect B 200E PowerConnect B 300 PowerConnect B 4100 PowerConnect B 5000 PowerConnect B 5100 PowerConnect B 7500 series PowerConnect B 7600 PowerConnect B 7800 PowerConnect B 8000 PowerConnect B VA 40FC 2U PowerConnect B 4900 PowerConnect B 5300 PowerConnect B AP7420 Brocade Encryptio
3. 53 1001792 01 mn January 31 2010 Fixed Rack Mount Kit Installation Procedure Supporting PowerConnect B 200E 300 4100 4900 5000 5100 5300 7500 series 7600 7800 8000 AP7420 Encryption Switch and VA 40FC 53 1001792 01 AMMAN IK AKA VV ALITO TI N Notes Cautions and Warnings NOTE A NOTE indicates important information that helps you make better use of your computer A CAUTION See the safety and regulatory information that shipped with your system For additional regulatory information see the Regulatory Compliance Homepage on www dell com at the following location www dell com regulatory_compliance CAUTION A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed DANGER A DANGER indicates a potential for property damage personal injury or death Information in this document is subject to change without notice 2009 Dell Inc All rights reserved Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc is strictly forbidden Trademarks used in this text Dell the DELL logo Inspiron Dell Precision Dimension OptiPlex Latitude PowerEdge PowerVault PowerApp Dell OpenManage and the YOURS IS HERE logo are trademarks of Dell Inc Intel Pentium and Celeron are registered trademarks of Intel Corporation in the U S and other countries Microsoft Windows Windows Server MS DOS and Windows Vista
4. binet depth and tighten the Item 6 screws to a torque of 9 in lbs 10 cm kgs Repeat step 1 through step 3 to attach the left rear bracket Item 3 to the left front bracket Item 2 Fixed Rack Mount kit Installation Procedure 53 1001792 01 a 1 Bracket front right 6 Screw 6 32 x 1 4 in flathead Phillips 4 Bracket rear right FIGURE 4 Position the rear and front brackets Attaching rear brackets to cabinet rails Complete the following steps to attach the rear brackets to the cabinet rails 1 Attach the right rear bracket Item 4 to the right rear cabinet rail using two 10 32 x 5 8 in screws Item 7 and two retainer nuts Item 8 Figure 5 2 Repeat step 1 to attach the left rear bracket Item 3 to the left rear cabinet rail 3 Tighten the 10 32 x 5 8 in screws Item 7 to a torque of 25 in lbs 29 cm kgs ATTENTION Connect the power cords to a grounded outlet only Ensure that any power cord is routed so that it is not exposed to stress Leave a minimum service loop of 6 in in the power cord s at the connection to switch This allows enough freedom of movement to plug and unplug the power cord s 4 Provide power to the switch by connecting the power cord s to the power connectors on the switch and a power outlet Some switches require you to flip a power switch to be powered on NOTE Do not connect the switch to the network until the IP address is correctly set Refer to the appropriate hardware
5. hillips 3 Bracket rear left 7 Screw 10 32 x 5 8 in panhead Phillips 4 Bracket rear right 8 Retainer nut 10 32 FIGURE 1 Items in Fixed Rack Mount Kit Installation procedure ATTENTION The switch must be turned off and disconnected from the fabric during this procedure NOTE Although this document describes how to install a 1U 1 5U and 2U switch the illustrations show a 1U switchasa typical configuration Complete these tasks to install the switch in a cabinet e Attaching front brackets e Installing the switch in the cabinet e Attaching rear brackets to front brackets e Attaching rear brackets to cabinet rails Fixed Rack Mount kit Installation Procedure 53 1001792 01 Attaching front brackets Complete the following steps to attach the front brackets to the switch I 2 4 1 5 Position the right front bracket Item 1 with the flat side against the right side of the switch Figure 2 Insert two 8 32 x 5 16 in screws Item 5 into one of the pairs of vertically aligned holes in the bracket and then into the pair of holes on the side of the switch To install the switch in a recessed position in the cabinet use the bracket holes that are set back from the end of the bracket Insert each 8 32 x 5 16 in screw Item 5 through the holes in the bracket and into the corresponding hole in the switch Tighten all 8 32 x 5 16 in screws to a torque of 15 in lbs 17 cm kgs Repeat step 1 thr
6. n Switch Installation requirements Allow 15 to 30 minutes to complete this procedure Note the following requirements to ensure correct installation and operation e Provide space in a 19 in 48 3 cm EIA cabinet as required for the switch type with a minimum distance of 28 25 in 71 76 cm and a maximum distance of 29 88 in 75 90 cm between the front and back rails e Verify that the additional weight of the switch does not exceed the cabinet s weight limits Fixed Rack Mount kit Installation Procedure 3 53 1001792 01 e Ensure that an electrical branch circuit with the following characteristics is available Required voltage and frequency as indicated in the hardware reference manual 200 230 VAC is always preferred Protection by a circuit breaker in accordance with local electrical codes Supply circuit line fusing and wire size that conform to the electrical rating on the switch nameplate Grounded outlet compatible with the power cord and installed by a licensed electrician e Ensure that all equipment installed in the cabinet is grounded through a reliable branch circuit connection Do not rely on a secondary connection to a branch circuit such as a power strip e Ensure that the cabinet is mechanically secured to ensure stability e Ensure that the air temperature at the fan inlet is less than 104 Fahrenheit 40 Celsius during switch operation e Ensure that the airflow available at the air vents mee
7. ough step 5 to attach the left front bracket Item 2 to the left side of the switch Bracket front right Screw 8 32 x 5 16 in panhead Phillips FIGURE 2 Position the front bracket Installing the switch in the cabinet Complete the following steps to install the switch in the cabinet 1 Position the switch in the cabinet Figure 3 providing temporary support under the switch until the rail kit is secured to the cabinet Attach the right front bracket Item 1 to the right front rack rail using two 10 32 x 5 8 in screws Item 7 and two retainer nuts Item 8 Repeat step 2 to attach the left front bracket Item 2 to the left front rack rail Tighten all 10 32 x 5 8 in screws Item 7 to a torque of 25 in Ibs 29 cm kgs Fixed Rack Mount Kit Installation Procedure 53 1001792 01 Bracket front right 7 Screw 10 32 x 5 8 in panhead Phillips Bracket front left 8 Retainer nut 10 32 NOTE The figure above is shown with a recessed mounting configuration on the left and a flush mounting configuration on the right You can select either mounting option FIGURE 3 Position the switch in the cabinet Attaching rear brackets to front brackets Complete the following steps to attach the rear brackets to the front brackets 1 2 3 4 Position the right rear bracket Item 4 inside the right front bracket Item 1 Figure 4 Attach the brackets using four 6 32 x 1 4 in screws Item 6 Adjust the brackets to ca
8. ts the minimum requirements for the switch ATTENTION Install the switch with the fan side facing the air intake aisle The chassis air intake is on the fan side and exhaust is on the port side Tool requirements and parts list The following items are required to install a switch using the fixed rack mount kit e Clamps or other means of temporarily supporting the switch in the cabinet e Phillips 2 screwdriver with torque capability e 61 4 in slotted blade screwdriver with torque capability ATTENTION Use the screws specified for use with the switch Longer screws can damage the switch Ensure that the items listed in Table 2 and illustrated in Figure 1 are included in the kit TABLE 2 Parts list Item Description Quantity 1 Bracket front right 1 2 Bracket front left 1 3 Bracket rear right 1 4 Bracket rear left 1 5 Screw 8 32 x 5 16 in panhead Phillips torque to 15 in Ibs 17 cm kgs 12 6 Screw 6 32 x 1 4 in flathead Phillips torque to 9 in Ibs 10 cm kgs 8 7 Screw 10 32 x 5 8 in panhead Phillips torque to 25 in Ibs 29 cm kgs 8 8 Retainer nut 10 32 8 4 Fixed Rack Mount kit Installation Procedure 53 1001792 01 12x 8x O 8x 8x amp F DI 8 32 x 5 16 in 6 32 x 1 4 in 10 32 x 5 8 in 10 32 1 Bracket front right 5 Screw 8 32 x 5 16 in panhead Phillips 2 Bracket front left 6 Screw 6 32 x 1 4 in flathead P