Home

Dell Force10 E300 Upgrade Guide

image

Contents

1. command TeraScale to ExaScale Upgrade Procedure Step Command Syntax Command Mode Purpose forcel0 show chassis Manufacturing Info Chassis Type E600i Chassis Mode ExaScale Chassis Epoch 10 4 micro seconds Chassis MAC 00 01 e8 41 cb 36 Serial Number TY000001140 Part Number 7520023900 Vendor Id 04 Date Code 01012008 Country Code 01 Product Rev OS TeraScale to ExaScale Upgrade Procedure ExaScale to TeraScale Downgrade Step Command Syntax Command Mode Purpose 1 chassis chassis mode terascale EXEC Privilege Change the chassis mode to TeraScale Forcel0 chassis chassis mode terascale Chassis mode changed to TeraScale mode Please reload chassis now System configuration has been modified Save yes no y Proceed with reload confirm yes no y 2 Turn the On Standby switch to Power off the chassis Standby AC Turn the Remote Power Source to Off DC 3 Replace the ExaScale RPMs SFMs and linecards with TeraScale RPMs linecards and SFMs Refer to the RPM SFM and Linecard documentation for installation and replacement details 4 Turn the On Standby switch to ON Power on the chassis AC Turn the Remote Power Switch to ON DC The chassis automatically powers up with a TeraScale image if the RPM has been programmed to boot from particular FTP location or Flash that points to a TeraScale image If no image is configured g
2. TeraScale to ExaScale Upgrade Procedure The E Series TeraScale is easily upgraded to Force10 Networks E Series ExaScale These upgrade requirements outline the necessary components and procedures required to upgrade the E1200i with FTOS version 8 1 1 0 Direct any questions regarding the upgrade to Force10 Networks Customer Support E mail support force1Onetworks com Web www forcel Onetworks com support Telephone US and Canada 866 965 5800 International 408 965 5800 Supported Hardware Minimum Software Hardware Catalog Number Version Required E1200i Chassis ote 1 ee cokes AC Power Supply 2800W CC E1200I 2800W AC 8 1 1 1 DC Power Entry Module CH E1200I DC 8 1 1 1 Route Processor Module ExaScale LC EH RPM 8 1 1 1 Switch Fabric Module ete 2 CC E SFM3 8 1 1 1 10 port 10GE line card 10M CAM LC EH 10GE 10S 8 1 1 1 10 port 10GE line card 40M CAM LC EJ 10GE 10S 8 1 1 1 Fan Tray CC E 1200I Fan 8 1 1 1 Note 1 Do not mix AC and DC power supplies Note 2 E Series ExaScale systems and FTOS Release 8 1 1 0 requires SFM version 752 00265 03 Rev 01 or higher Use the show sfm command to determine if your SFMs need to be upgraded Do not mix SFMs All the SFMs in the chassis must run the required minimum software version FORCE Upgrading Hardware Warning A e Electrostatic discharge ESD damage can occur when components are mishandled Always wear an ESD preventive groun
3. Vendor Id 04 Date Code 11252003 Country Code 01 Product Rev 02 Ae ae TeraScale to ExaScale Upgrade Procedure
4. 00 00 48 SRPM1 P CP TSM 5 SFM FOUND Found SFM 3 00 00 48 SRPM1 P CP TSM 5 SFM FOUND Found SFM 2 00 00 47 SRPM1 P CP TSM 5 SFM FOUND Found SFM 1 00 00 47 SRPM1 P CP TSM 5 SFM FOUND Found SFM 0 The show sfm command includes information for any SFM that needs to be upgraded Figure 3 FPGA Upgrades FTOS version 8 1 1 1 introduces an automatic FPGA Upgrade process It allows easy upgrades to newer SFM version by implementing an auto detection of mismatched SFM version The upgrade to the mismatched SFMs is done automatically Manual upgrade are still supported for one or all SFMs TeraScale to ExaScale Upgrade Procedure 2 Automatic upgrade during boot reboot reload or restart The FPGA auto upgrade takes place when any SFMs in the chassis run an FPGA version lower than the version running during the boot reboot reload and restart operations During the auto upgrade process the system displays messages relaying the status of the upgrade process Figure 1 To verify the result of the SFM version upgrade use the show sfm command Figure 1 FPGA Automatic Upgrade Messages TORT TNR Tene nT eT TT nT errr SFM SFM SFM SFM SFM SFM SFM SFM S Star Plea SFM 0 5 0 5 1 5 1 5 2 5 2 5 3 5 3 5 4 5 4 5 Warning Warning Warning ting auto upgrade of SFMs to newer version 0x0 0 3 se wait until upgradation of all 5 SFMS is complete will restart its
5. FM is complete SFM will reset itself after upgradation of 1 SFM is complete KKK RK KR KKK RK KR KKK RK KK KKK RK KK KKK RK KK KKK RK KKK KK RK KKK KK KK KKK KK KKK KK KK KKK KK SFM 0 9 upgrade started SFM 0 9 is upgraded to revision 0x0 0 3 KKK KKK KKK KKK KKK KKK KK KKK KK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKKKEKEK Warning Warning Warning Auto upgrade on 1 SFM to version 0x0 0 3 is complete Resetting SFM Please wait KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKEK SFM 0 9 reset started 00 08 29 SRPM1 P CP STSM 6 SFM USR_RESET SFM 0 reset by user reset SFM 0 successful KKEKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKEK Warning Warning Warning Resetting on 1 SFM to revision 0x0 0 3 is complete RERUN IIIT IID ITI III III III III III A TeraScale to ExaScale Upgrade Procedure 4 TeraScale to ExaScale Upgrade Be sure you have the correct ExaScale hardware ready for installation prior to beginning this upgrade Refer to Supported Hardware for the list of hardware required for E Series ExaScale with FTOS 8 1 1 1 Step Command Syntax Command Mode Purpose 1 Turn the On Standby switch to Power off the chassis Standby AC Turn the Remote Power Source to Off DC 2 Replace the TeraScale RPMs SFMs and linecards with ExaScale RPMs SFMs and linecards Refer to the RPM SFM and Linecard doc
6. d strap when handling RPMs SFMs or line cards After you remove the original packaging place RPMs SFMs and line cards on an antistatic surface e Do not supply power to your system until the PEM or Power Supply Air Filter Fan Tray are installed and verified and RPMs SFMs and line cards have been installed e To avoid chassis over temperature condition install blanks for RPMs SFMs and line card slots not in use Always replace cards or blanks immediately ExaScale SFM Requirements E Series ExaScale systems and FTOS Release 8 1 1 1 require SFM version 752 00265 03 Rev 01 or higher Earlier SFMs do not support line rate following the ExaScale 8 1 1 1 FPGA upgrade Do not mix SFMs All the SFMs in the chassis must run the required minimum software version The automatic upgrade process takes place regardless of the SFMs you have installed If you have one or more SFMs that are earlier than 752 00265 03 Rev 01 a SYSLOG message Message 1 appears during the upgrade Message 1 SYSLOG messages during FPGA Automatic Upgrade 00 00 52 SRPM1 P CP TSM 5 SFM OLDER VERSION Older version of SFM 8 detected 00 00 52 SRPM1 P CP TSM 5 SFM FOUND Found SFM 8 00 00 51 RPM1 P CP TSM 5 SFM OLDER VERSION Older version of SFM 7 detected 00 00 51 SRPM1 P CP TSM 5 SFM FOUND Found SFM 7 00 00 51 SRPM1 P CP TSM 5 SFM FOUND Found SFM 6 00 00 50 SRPM1 P CP TSM 5 SFM FOUND Found SFM 5 00 00 49 SRPM1 P CP TSM 5 SFM FOUND Found SFM 4
7. elf after upgradation of all 5 SFM is complete KR KK RR KR KKK RK KR KKK RK KR KKK RK KR KK RK KK KKK RK KK KKK KK KK KKK KK KKK KK KKK KKK KK KKK KK upgrade started is upgraded to revision 0x0 0 3 upgrade started is upgraded to revision 0x0 0 3 upgrade started is upgraded to revision 0x0 0 3 upgrade started is upgraded to revision 0x0 0 3 upgrade started is upgraded to revision 0x0 0 3 KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKEK Warning Warning Warning Auto upgrade on all 5 SFM to version 0x0 0 3 is complete Rebooting chassis LII KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKEK N Verify the result of the SFM version upgrade using the show sfm command TeraScale to ExaScale Upgrade Procedure Automatic upgrade for one or more new SFMs The FPGA auto upgrade takes place when any newly inserted SFM runs an FPGA version lower than the version running on the SFMs in the chassis During this auto upgrade process the system displays messages relaying the status of the upgrade process Figure 2 To verify the result of the individual SFM version upgrade use the show sfm slot command Figure 2 New SFM Automatic Upgrade Messages n A kkkkkkkk kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkx k K Warning Warning Warning Starting auto upgrade of SFMs to newer version 0x0 0 3 Please wait until upgradation of 1 S
8. o to Steps 5 and 6 5 Ctrl Shift 6 when prompted Stop the chassis in boot user mode and during boot mode configure it to boot from FTP or Flash and reload 6 boot change BOOT_USER Tell the system where to access the primary secondary default TeraScale FTOS image used to boot the system After entering the keywords and Enter primary to configure the boot desired option press Enter The parameters used in the first attempt software prompts you to enter the to boot the system following Enter secondary for when the primary operating system boot selection is not available Enter default to configure boot parameters used if the secondary operating system boot parameter selection is not available The default location should always be the internal flash device flash and a verified image should be stored there boot device ftp tftp flash slotO e image file name e IP address of the server with the image username and password for FTP 7 reload BOOT_USER Restart the chassis to boot with the specified TeraScale image TeraScale to ExaScale Upgrade Procedure Step Command Syntax Command Mode Purpose 8 show chassis EXEC Privilege We can confirm using the show chassis command orce10 show chassis b Manufacturing Info Chassis Type E1200 Chassis Mode TeraScale Chassis Epoch 10 4 micro seconds Chassis MAC 00 01 e8 05 db 05 Serial Number 7520010900 Part Number 0
9. umentation for installation and replacement details 3 Turn the On Standby switch to ON Power on the chassis AC Turn the Remote Power Switch to ON DC 4 The chassis automatically powers up with a ExaScale image ifthe RPM has been programmed to boot from particular FTP location or Flash that points to a TeraScale image If no image is configured go to Steps 5 and 6 5 Ctrl Shift 6 Stop the chassis in boot user mode and configure it to boot from FTP or Flash and reload 6 boot change BOOT_USER Tell the system where to access the primary secondary default ExaScale FTOS image used to boot the system After entering the keywords and Enter primary to configure the boot desired option press Enter The parameters used in the first attempt software prompts you to enter the to boot the system following e Enter secondary for when the boot device ftp tftp flash slot0 primary operating system boot image file aime i selection is not available e IP address of the server with the Prier detauit 19 canngure Boor imade parameters used if the secondary g operating system boot parameter username and password only for Ss l selection is not available The default FTP i location should always be the internal flash device flash and a verified image should be stored there 7 reload BOOT_USER Restart the chassis to boot with the specified ExaScale image 8 show chassis EXEC Privilege We can confirm using the show chassis

Download Pdf Manuals

image

Related Search

Related Contents

Virtu USA UM-3089-G-ES Installation Guide  Tripp Lite SmartOnline 220-240V 3kVA 2.1kW On-Line Double-Conversion UPS, SNMP, Webcard, Tower, C20 inlet, DB9 Serial  Moteur M62  2Prima o botão + ou    UP Mini 3D Printer User Manual v 2013.1.31  “NÓVASOFT VENTAS”  Rust-Oleum Automotive 260771 Use and Care Manual  