Home
        Dell OpenManage Server Administrator Version 5.1 Read me
         Contents
1.  Depending on your network and proxy configurations and whether you  are using Mozilla browser  you may need to  enter the exact IP address of the RAC controller you are trying to  access in the  No Proxy for  field of your browser    Perform the following steps    1  Open your Mozilla browser    2  Click  Edit     3  Click  Preferences         4  Click  Advanced  in the left sidebar    5  Click  Proxies  in the left sidebar    6  Enter the RAC IP address in the  No Proxy for   field   7  Click  OK  and then close the browser      Tf the out of band RAC user interface was spawned off from the  Server Administrator home page with a Mozilla browser  strings with  extended ASCII characters may not display correctly in certain  languages  This issue occurs because the browser is set to the UTF 8    character set by Server Administrator  To correct this issue  change  the browser character coding to ISO 8859 1  For Japanese and    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     Chinese  UTF 8 is the correct encoding for RAC pages       To view the RAC Web based interface when using Mozilla 1 6  you  must configure your cookie settings to  Enable all cookies      To enable all cookies  go to the menu options and click    Edit   gt  Preferences   gt  Privacy  amp  Security   gt  Cookies   and then  select  Enable all cookies   If you do not perform these steps  you   will not be able to log in to the Web interface and you will receive  a m
2.  Run In Terminal   button for applications that do not open a window of their own  the   start sh  script opens its own window   If you choose  Run In  Terminal   you must restart the racvnc service after installing  Dell OpenManage systems management applications by typing the  following command      service racvnc restart       When using Console Redirection on a managed system running Red Hat  Enterprise Linux  the focus  cursor moved back over an object   follows the cursor  Occasionally  the text windows in Console  Redirection lose focus  Before attempting to type in a text window  in a Console Redirection window  click the mouse in the text  window s spacebar or top menu bar to ensure that your target text  window has the focus on the correct window or application that you  are attempting to use     FREER    Information in this document is subject to change without notice    C  2006 Dell Inc  All rights reserved     Reproduction in any manner whatsoever without the written permission  of Dell Inc  is strictly forbidden     Trademarks used in this text   Dell    PowerEdge    PowerVault   and   Dell OpenManage  are trademarks of Dell Inc    Intel  is a registered  trademark of Intel Corporation   Microsoft    Windows Server   and   Windows NT  are registered trademarks of Microsoft Corporation    Red Hat  is a registered trademark of Red Hat  Inc    SUSE  is a  registered trademark of Novell Inc    EMC  and  Navisphere  are  registered trademarks of EMC Corporation   VER
3.  be available  The  browser displays the error   Virtual Media Plug in is not installed  or running     This issue is caused by new Java applet security  features of Mozilla 1 7 3 and newer  Perform the following steps to  manually install the plug in for that specific browser    1  Log in to DRAC 4 and navigate to the  Properties  page    2  Change the Web address in the browser window from   https    lt DRAC4 IP address gt  cgi main  to   https    lt DRAC4 IP address gt  rac4vm xpi   and press Enter     Mozilla prompts you with an  Opening rac4vm xpi  dialog   allowing you to save the file to your local file system     3  Click  OK  and save the file to a temporary location  should  be your home directory  by default      file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     4  After saving the file  close the browser     5  Restart the browser  and specify the Web address of the   rac4vm xpi  file  for example  file    root rac4vm xpi      6  Mozilla presents you with the  Software Installation  dialog   Click the  Install  button to continue     7  After installation completes  close and restart the browser     8  Now  log in to DRAC 4  and navigate to the Virtual Media link   The plug in is installed and ready to use     9  At this point  delete the    rac4vm xpi  file       The cfgDNSServerl and cfgDNSServer2 properties of group  cfgLanNetworking may be set to identical values while swapping  addresses  Some performance may be lost 
4.  be supported     Example    1  Click  Main System Chassis  under  System Component Tree    2  Click  Fans  under  Main System Chassis     3  Click  Alert Actions  on the tab menu bar    4  Click the  Back  button on the browser     This action takes you to the  Fan Probes  page  leaving the tab  menu bar unchanged  This action places the  Fan Probes  page  under  Alert Actions  on the tab menu bar instead of under   Fan Probes        Selecting the boot sequence under the BIOS  Setup  tab does not  re enable boot devices that have been previously disabled in  the System Setup Program       The links on the Server Administrator home page might lock up after  repeated random clicking  To resolve this situation  refresh the  browser by pressing  lt F5 gt  or by clicking the browser  Refresh   button       All unsecured HTTP requests to Server Administrator receive an  invalid response  Server Administrator runs only one instance of  the Web server  which is secure  Make all connections through  https    lt ip address gt     lt port number gt   Any  http    lt ip address gt     lt port number gt   request for connection with the server receives an  invalid response       Jf the browser used with Server Administrator indicates that it  cannot display a page or perform an action  ensure that the browser  is in online mode  To go online  perform the following       If you are using Internet Explorer  click  File  on the  menu bar and deselect the  Work Offline  option  When  Work  O
5.  level  timer  heavy resource stress on the system makes it more likely   that a short keep alive interval  less than 120 seconds  will not   be measured accurately  and the configured action may be triggered   In particular  the issue will be more prevalent in a system which   has only one CPU  Hyper Threading is not supported or is disabled   and the system is subjected to persistent stressful conditions such   as resource depletion and CPU running at 100  usage with  significantly more threads than normal usage     The Auto Recovery feature is not enabled by default  If the Auto    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     Recovery feature has been enabled  increase the System Reset Timer  value to at least 120 seconds   78425       Tf you install Server Administrator on a system that includes a  underscore in its hostname  you must use the target system s ip  address in the browser s URL to launch Server Administrator as  hostnames with underscores are not supported and can lead to  unexpected behavior  For example  assuming Server Administrator is  listening on port 1311   https   192 168 2 3 1311     ISSUES FOR SERVER ADMINISTRATOR RUNNING ON ALL MICROSOFT WINDOWS  OPERATING SYSTEMS      Execute all Server Administrator CLI commands from a 32 bit Windows  command prompt  Acceptable ways to access the 32 bit command prompt  are by clicking  Start  gt  Programs  gt  Accessories  gt  Command Prompt   or by clicking  Start  
6.  options is disabled  If the    reboot  option is enabled  the system will automatically reboot   and you will not be forced to shut down by removing the power cord    126837       While browsing through IT Assistant  if the SNMP protocol is  disabled and the CIM protocol is enabled  the redundancy status is  shown as lost even though the system has full redundancy  To  confirm the correct state of the system  use the Server  Administrator user interface       If you have a RAID 1 virtual disk on a CERC SATA 1 5 6ch  controller  performing a Format or Split Mirror operation  may fail  Dell is working to resolve this problem       When issuing the Server Administrator command line  omreport  system version  outc  lt filename gt    be sure to specify an absolute  path name for the output file  for example   c  out txt   otherwise   the output file will be empty       Issuing the  omreport system esmlog alertlog cmdlog  fmt tbl   command on the CLI can result in XML parsing errors if the size  of the log is very large  Use the GUI or the  omreport system  esmlog alertlog emdlog  CLI command to view the contents of  the log  124997       For complex  omconfig  CLI commands that contain multiple commands  in one command line  the CLI may report a success status for the  command even if part of the command failed  To avoid this issue   run only one command per command line  The current settings can be  confirmed by performing the corresponding  omreport     command       Some compl
7.  or unsupported type   browser may not be reported to the user  In such cases  the user  may see unexpected or incomplete results     NOTE  The operating system media browser install may not be the  version supported by Server Administrator  See the appropriate Red  Hat Enterprise Linux operating system documentation to upgrade the  base browser install version to the supported version       DRAC 5 firmware version 1 0 or greater is required for systems  installed with DRAC 5       On systems installed with a DRAC 4 1 and DRAC 4 P firmware version  1 0 or greater is required       RAC firmware version 3 20 or greater is required for DRAC MI   DRAC III XT  ERA  and ERA O     ERE EEE  RELEASE HIGHLIGHTS  FEREEEEEHEEEHEEEHEEEE E H E EE HEEE HHEH      Added support for SUSE Linux Enterprise Server  version 10   on    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     Intel Extended Memory 64 Technology  Intel EM64T  systems     NOTE  DRAC 5 support on SUSE Linux Enterprise Server  version 10  is  limited to the Manage Node and to the CLI only  DRAC 5 does not support  the Out of Band GUI on the Management station       Added support for Microsoft Windows Small Business Server 2003 R2  on Intel EM64T systems       Added support for Microsoft Multilingual Interface  MUD  on the  Microsoft Windows Storage Server 2003 R2 operating system       Added support for the following Dell PowerEdge systems  840  860   and 1900       Added support for t
8.  org starting with kernel 2 6 14     Red Hat Enterprise Linux     Server Administrator provides precompiled dcdbas and dell_rbu  modules for Red Hat Enterprise Linux version 3 and 4  These  drivers are expected to ship with future Red Hat Enterprise Linux  version 3 and 4 Updates     SUSE Linux Enterprise Server     These drivers ship with SUSE Linux Enterprise Server version 9  Service Pack 3  SP3  and version 10  It is expected that future  SUSE Linux Enterprise Server version 9 and 10 Service Packs will  continue to ship these drivers     If the drivers are available with the operating system  Server  Administrator will use those versions of the drivers  If the   drivers are not available with the operating system  Server  Administrator will use its precompiled modules on Red Hat  Enterprise Linux version 3 and 4  If precompiled drivers are not  available with the operating system or Server Administrator    Server Administrator uses its Dynamic Kernel Support  DKS  feature  to build the drivers when needed  See the  Dell OpenManage  Installation and Security User s Guide  for more information about  DKS       When using the Storage Management Service  the DSM SA Data Manager  must first be stopped before Adaptec controllers are updated       Detailed information on the Storage Management Service is available  in the Storage Management Service online help  After installing and  launching Server Administrator  you can access the Storage Management  Service online help by sel
9.  prompt   issuing an  omreport  or  omconfig  command from the same  prompt causes an error  You must open a new command prompt and issue  commands from the new window       If the command log page in the Server Administrator GUI displays an  error message indicating that the XML is malformed  you must clear  the command log from the CLI using the  omconfig system cmdlog  action clear    command     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM       After a  Reset to Defaults  operation of the BMC Management  controller  the first user configuration operation will fail if it  is a single user configuration item  such as enabling or disabling  a user or changing user name   Always change a combination of two  user configuration items  such as enabling or disabling a user and  changing user name  concurrently during your first configuration  operation  136599       On PowerEdge 750 systems  if you disable the Power button in  Server Administrator  the system does not power cycle or power down  in the event of system instability and or blue screens  In such  cases  you need to physically remove the power cord from the system  to power down the unit  As the startup and recovery options in the  operating system override those of Server Administrator  you need  to configure them in the operating system to restart the system  after a crash     NOTE  The above situation is applicable only when the  reboot   option in the startup and recovery
10.  tab and ensure that   Auto Recovery  is selected  The default value of the  Action On  Hung Operating System Detection  setting is  None    None  indicates  that detection will not be performed       RAC firmware 2 0 and higher does not support passwords with special  characters  non alphanumeric  only for RAC user IDs logging in using  the Web based interface  with Local RAC Authentication   If you  created RAC user IDs using previous versions of the firmware or if  you created user IDs using Server Administrator that is running  version 2 0 firmware on the managed system  you cannot log in to  the RAC     Use one of the following four methods to correct this issue     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM       Change your passwords before updating the firmware    OR     Use the following CLI command to change the password    omconfig rac users username xx userpassword yy   where  xx  is the original userid and  yy  is the new password    OR     Change the password through Server Administrator using the  User   tab  Ensure that the check box to change the password is checked   Enter a new password  and then enter it again to validate the  change    OR      Use the racadm utility to change the password      racadm config  g cfgUserAdmin  o cfgUserAdminPassword   i  lt usr_index gt   lt new_pwd gt      where  lt usr_index gt  is the index of the user database entry to be  modified and  lt new_pwd gt  is the new password      
11. 2000 SBS SP1       Microsoft Windows Server TM  2003 R2  32 bit and 64 bit  extensions   Standard  and Enterprise and x64 editions   Microsoft  Windows Server 2003 SP1  Web Edition   Microsoft Windows Storage  Server 2003 R2  includes Express  Standard  Workgroup  and  Enterprise editions   and Microsoft Windows Server 2003 SBS      Red Hat R  Enterprise Linux  AS  WS and ES    version 3 and 4   for Intel R  x86 and Intel Extended Memory 64 Technology  EM64T       SUSE R  Linux Enterprise Server  version 9 SP3 and 10  for Intel  EM64T  In XEN mode  support for service console only       VMware ESX service console  see www dell com vmware for details     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     NOTE  Please refer to the  ISSUES FOR THE DRAC 5  section of this  document for the supported managed server operating systems by  DRAC 5       Microsoft Internet Explorer 6 0  SP2  on Microsoft Windows Server 2003       Mozilla 1 7 11 on Red Hat Enterprise Linux  AS  ES  WS  version 3  and SUSE Linux Enterprise Server version 9 SP3 and 10       Firefox 1 5 on Red Hat Enterprise Linux  AS  ES  WS  version 4 and  SUSE Linux Enterprise Server version 9 SP3 and 10     NOTE  Please refer to the  ISSUES FOR THE DRAC 5  section of this  document for the browser supported by DRAC 5     NOTE  The Server Administrator browser attempts to use the  available browser in all cases  However  under certain  circumstances  using an unsupported  version
12. FREER  DELL OPENMANAGE TM  SERVER ADMINISTRATOR VERSION 5 1 README  FEET    NOTE  This readme provides information for Dell OpenManage Server  Administrator version 5 1     This file contains updated information for your  Dell OpenManage  Server Administrator User s Guide  and any other technical  documentation included with Server Administrator     NOTE  See the Dell OpenManage Install 5 1 readme   readme_ins txt     which is located under the  readme  folder on the   Dell TM  PowerEdge TM  Installation and Server Management  CD  for the latest installation information and issues specifically  related to Server Administrator     NOTE  See the Dell OpenManage Storage Management readme  located in  the  srvadmin docs readme  directory on the  Dell PowerEdge  Installation and Server Management  CD  for supplemental  information regarding the Storage Management Service     NOTE  Server Administrator versioning skipped major versions 3 and 4  so that the Server Administrator and OpenManage versions  would match going forward   The Server Administrator documentation includes the  User s Guide     Messages Reference Guide    CIM Reference Guide    Command Line  Interface  CLI  User s Guide    SNMP Reference Guide   and   Compatibility Guide   You can access the documentation from the  documentation CD or from the Dell support website at   support dell com    This file contains the following sections     Criticality    Minimum Requirements    Release Highlights    Installation    Us
13. ITAS  is a registered  trademark and  Backup Exec  is a trademark of VERITAS Software  Corporation     Server Administrator uses the OverLIB JavaScript library  This  library can be obtained from  http   www bosrup com web overlib       Other trademarks and trade names may be used in this document to  refer to either the entities claiming the marks and names or their  products  Dell Inc  disclaims any proprietary interest in trademarks  and trade names other than its own     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     July 2006    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     
14. M     As explained in the Microsoft KB article  use the Registry  Editor   regedit exe   to browse to the following key     HKEY_ LOCAL MACHINE Software Microsoft Windows CurrentVersion   Internet Settings     If it is not present  create a registry item called   DialupUseLanSettings  and set a value of  1   Make sure the value  type is  DWORD      Note  HotFix Q818060 may still fail to install on Internet Explorer  6 0 SP1  If the error  This update requires Internet Explorer 6 0  SP1 to be installed  occurs  follow these instructions     1  Unzip  Q818060 Eng IE6 zip      2  From a Windows command shell  enter  Q818060 exe  C  to  extract the HotFix files to a directory     3  In the command shell  switch to the directory and then enter   jeupdate exe Q818060      4  Launch Internet Explorer  open the  Help  menu  and select   About Internet Explorer   Verify that  Q818060  appears in  the  Update Versions  field     FREER  KNOWN ISSUES  FREER    This section provides information on open issues with this release of  Server Administrator     ISSUES FOR SERVER ADMINISTRATOR RUNNING ON ALL SUPPORTED OPERATING  SYSTEMS      Due to resource availability  inventory collection may terminate  unexpectedly and restart  If this occurs  the folder   C  Temp invcol  may be left as an artifact  The presence of this  folder does not affect functionality of the inventory collection   The folder may be deleted if desired   138549       After installing Server Administrator from the command
15. UI  is renamed with a name containing  multiple blank and consecutive spaces  the name is truncated to a  single space after  Apply  is clicked       When the  Open in a New Window  option is selected in the Storage  Management Service Advanced Create VDisk Wizard  the current page  is opened in a new window  rather than launching the selected  option     STORAGE MANAGEMENT SERVICE ISSUES FOR RED HAT ENTERPRISE LINUX  OPERATING SYSTEMS      Tf a physical disk in a RAID 1 concatenated virtual disk fails   the virtual disk is in a Degraded state  The Check Consistency  operation should not be performed on a virtual disk while it  is in a degraded state  However  the task drop down menu  for a degraded RAID 1 concatenated virtual disk may display the   Check Consistency  option  Do not perform a consistency  check until after appropriate actions are performed to restore the  virtual disk  Dell is working to resolve this problem       With Chinese or Japanese language browser settings  using the  Storage Management Service Advanced Create VDisk Wizard may  occasionally result in text overflowing the bottom of the  side by side blue text boxes     NOTE  The Remote Access Service is supported on PowerEdge 650  700   750  800  830  840  850  860  1600SC  1650  1750  1800  1850   2600  2650  2800  2850  4600  6600  6650  6800  and 6850 systems  only     The following subsections list the currently known issues regarding    implementation and operation of your RAC and the Remote Acces
16. Windows 2000  perform the following steps       Under  Miscellaneous   select the  Allow Meta Refresh  radio  button       Under  Active Scripting   select the  Enable  radio button   7  For Windows 2003  perform the following steps       Under  Miscellaneous   select the  Allow Meta Refresh  radio  button       Under  Active Scripting   select the  Enable  radio button       Under  Active scripting   select the  Allow scripting of  Internet Explorer web browser controls  radio button       Click  OK  and restart your browser     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM       To allow Single Sign on for Server Administrator  without prompts  for user credentials  perform the following steps     1  Navigate to  Tools  in Internet Explorer    2  Under  Tools   click  Internet Options    3  Under  Internet Options   click the  Security  tab   4  Select  Trusted sites     5  Click the  Custom Level  button     6  Under  User Authentication   select the  Automatic Logon with  current username and password  radio button  Press    OK    to exit  the    Custom Level    window     7  Now select the    Advanced    tab  and under  HTTP 1 1 settings    make sure  Use HTTP 1 1  is checked     8  Click  OK  and restart your browser       If you run a security scanner tool  such as Nessus  against the  Server Administrator Web server  certain security warnings against  port 1311 running the Server Administrator Web server might be  displayed  T
17. cess controller uses FTP protocol to perform some of  the Dell OpenManage commands  If a firewall is installed in the  system  it may cause these commands to fail     The following Server Administrator CLI commands use FTP protocol to  communicate with the RAC      omconfig rac uploadcert    omconfig rac generatecert     The following racadm commands use FTP protocol to communicate with  the RAC      racadm sslcertupload    racadm sslcsrgen    racadm fwupdate       If the RAC configuration is reset to factory defaults using the   racadm racresetcfg  command  the RAC configuration tab in Server  Administrator does not reflect the reset configuration settings  until the system reboots  Also  the RAC configuration page in  Server Administrator cannot be used to make any configuration  changes until the system reboots       The RAC does not support local RAC user IDs with special  characters  When adding a local RAC user  use only alphanumeric  characters for the user name       While the RAC is being reset  the Instrumentation Service cannot  read sensor data for certain systems  As a result  the voltage   temperature  and other probes may not be visible on the Server  Administrator home page until the RAC has completed resetting       The RAC may not send traps when your system is locked up  To enable  traps to be sent when the system is locked up  you must configure  the watchdog timer using the Server Administrator GUI  In the Server  Administrator GUI  click the  Properties 
18. d install Dell PowerEdge Diagnostics from  the Dell Support website at support dell com  Dell PowerEdge  Diagnostics is a stand alone application that can be run without  installing Server Administrator     EEE THEE  INSTALLATION    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     E E E E E H E H HEEE EHHH    For complete installation instructions  see the  Dell OpenManage  Installation and Security User s Guide      E E  USER NOTES  E E E E E E H E EE HEEE HHHH    This section provides information to help enhance your experience with  Server Administrator in particular implementations and environments       Server Administrator uses port 1311 as the default port  Port 1311  is a registered port number of Dell Inc  If another application is  configured to run on port 1311 before Server Administrator is  installed  the DSM SA Connection Service will not start after installation   Before you install Server Administrator  ensure that port 1311 is  not being used      You need to enable client side scripting in Internet Explorer before  starting Server Administrator  To do so  perform the following  steps    1  Navigate to  Tools  in Internet Explorer    2  Under Tools  click  Internet Options     3  Under  Internet Options   click the  Security  tab    4  Select the security zone that the system running Server  Administrator falls under   NOTE  This option should be set to  Trusted sites     5  Click the  Custom Level  button    6  For 
19. d this issue  update the net snmp RPM to version 5 1 3 1 0 13  or later via YaST Online Update       On systems running SUSE Linux Enterprise Server 9 SP3  Server  Administrator Web interface may freeze when clicking on components    in the tree view  left pane of the interface      To correct this issue  restart the connection service by running    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM      srvadmin services sh restart    or   omconfig system webserver action restart     from the command line  You must refresh the web interface and log  back into Server Administrator to continue     The following are open issues regarding the Storage Management  Service       When issuing certain  omconfig storage  CLI commands with  Power  User  privileges  the message  Error  User has insufficient  privileges to run command  omconfig  may be displayed  You must be  logged in as an Administrator to perform these actions       On a Windows Server 2003 system  it is strongly recommended that you  update to Service Pack 1 or later  Service Pack 1 is required to  fully support SAS technology       On a Windows 2000 system  it is strongly recommended that you update  to Service Pack 4 or later  Service Pack 4 is required to  fully support SAS technology       On a Red Hat Enterprise Linux 3 x system  Update 3 or later is  required for Storage Management and Update 7 or later is required to  fully support SAS technology  Dell strongly recommends t
20. e errors from being written to  the Event log       Uninstall the  Update Root certificates  component as detailed  in the first knowledge base article mentioned above     Note  This procedure may affect other programs as discussed in  the article       Install the Server Administrator certificate as a trusted  certificate     Note  This procedure may still prompt you to accept the  certificate when you log on to Server Administrator  but  will prevent the crypt32 errors from being logged to the  Event log     ISSUES FOR SERVER ADMINISTRATOR RUNNING ON RED HAT ENTERPRISE LINUX  OPERATING SYSTEMS      When starting Server Administrator from the Red Hat Enterprise Linux  console  kernel log messages may appear  To suppress these messages   perform the following steps     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     1  Edit the   etc sysconfig syslog  file and modify KLOGD_OPTIONS to  KLOGD_OPTIONS   c 4      2  Restart  syslog  by executing   etc init d syslog restart        When using the Mozilla browser on Red Hat Enterprise Linux operating  systems  the font and type size on the Server Administrator global  navigation bar appear different from the default font and type size  that Server Administrator uses       On systems running Red Hat Enterprise Linux 4 Gold  Intel x86 and Intel  Extended 64 bit architectures  with DRAC 4 installed  the CD device  will be listed under a Tertiary Channel instead of the Primary Channel   This i
21. ecting the Storage or lower level tree  object and clicking the Help button on the global navigation bar     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM       This service is supported on PowerEdge 650  700  750  800  830  840   850  860  1600SC  1650  1750  1800  1850  2600  2650  2800  2850  4600   6600  6650  6800  and 6850 systems only  It enables remote access to a  server that has lost its network connection or that has become  unresponsive  In this release of Server Administrator  the Remote  Access Service uses the following Remote Access Controllers  RACs    Dell Remote Access Card  DRAC  4 I  DRAC 4 P  DRAC III  DRAC III XT   Embedded Remote Access  ERA   or Embedded Remote Access  Option  ERA O        RACs also have their own CLI that is accessed through the  racadm   command  You can add racadm commands to a batch or script file to  automate various user tasks  To limit the stress load on the managed  system and RAC  you should add  sleep  or  delay  commands of one or  two seconds between the individual racadm commands       Unlike DRAC 3  configuration of DRAC 4 settings is not supported in  Server Administrator  Additionally  Server Administrator performs  minimal reporting of DRAC 4 properties  For DRAC 5  a limited  amount of NIC and User settings are configurable through Server  Administrator to allow the user to connect via Out Of Band to the  DRAC 5 card  For full configuration and reporting of all DRAC  attribut
22. er Notes    Known Issues  Sri ici EARL AADIMIAIA ARIA LEAAIGITIMIAIALRAALRARLAALIMITIALRAALEARLAALIRITIALRAALEARIAATIMITIALRAALRAAIAITIRITIALRAALEARIAATIAIAIAIRAALEARLAAD    CRITICALITY  FREE EHEEEHEEEEEE E H E EE HEEE HEHEHEHEH    file    Tl  htdocs SOFTWARF svradmin 5 1 en readme readme_sa txt 10 23 2012 1 31 47 PM     3   Optional    Dell recommends that you review specifics about the update to  determine if it applies to your system  The update contains changes  that impacts only certain configurations  or provides new features that  may or may not apply to your environment     FEET  MINIMUM REQUIREMENTS  FEET    This section provides information about the minimum requirements for  installing and using Server Administrator     Server Administrator 5 1 is supported on the  Installation and Server  Management    CD version 5 1     The following Dell PowerEdge systems are supported for    Dell PowerEdge Installation and Server Management  CD version 5 1   600SC  650  700  750  800  830  840  850  860  1600SC  1650  1655MC   1750  1800  1850  1855MC  1900  1950  1955  2600  2650  2800  2850   2900  2950  4600  6600  6650  6800  and 6850     The following Dell PowerVault system is supported for   Dell PowerEdge Installation and Server Management  CD version 5 1   NX 1950      Microsoft R  Windows R  2000 Server family  32 bit extension    includes Windows 2000 Server SP4  Windows 2000  Advanced Server SP3 and greater  and Windows 2000 Small Business  Server  SBS   and Windows 
23. es  it is recommended to use the  racadm  command       After installing Internet Explorer 5 0 or later  you may notice that  the automatic configuration and proxy setting information for each  connection is separate from the same information used for the LAN  connection  If you have both a dial up and a LAN connection at the  same time  Internet Explorer may block your access to the Internet     This blocking occurs because each connection in Internet Explorer  5 0 uses its own automatic configuration and proxy settings  When  you try to establish a PPP connection  Internet Explorer attempts  to use the dial up connection settings to access the Internet     You can find additional information about this issue in article   Q818060   Connections No Longer Use Local Area Network Automatic  Configuration and proxy settings  in the Microsoft Knowledge Base  KB   at  support microsoft com      To correct this problem  you must apply Microsoft IE HotFix Q818060  or KB839571 to Internet Explorer 6 0 SP1 on Windows 2000 server or  Windows 2003 server  HotFix Q818060 and KB839571 are available on  the  Server Manage Node  CD in the   srvadmin Windows HotFix   directory  See the following Microsoft support articles for further  instructions on applying this HotFix      Windows 2000 Server   http   support microsoft com  kbid 8 18060    Windows 2003 Server   http   support microsoft com kb 83957 1     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 P
24. essage that your username and password are incorrect       A dial up network connection to the remote access controller is  established by the RAC managed system software installer  The RAC  software will not work properly if this dial up connection is  deleted or if a proxy is set up in the Internet settings  An  InstallPPP utility is provided with the RAC software to restore the  RAC PPP connection  This utility can also correct Internet  connection problems with proxy server settings  when using the  Windows 2003 operating system  You can run the utility from the  Windows command prompt with the argument  CreateR ACConnection  as  shown below     c   gt installPPP CreateRACConnection      Applications that use InstallShield 3 x to install software may take  longer to install if RAC Services are running  To reduce the  software installation time  stop RAC Services before performing the  installation  You must restart RAC Services after the installation  is complete       Due to functional details that are specific to Windows Dynamic DNS  servers  the RAC internal PPP IP address is broadcast to the Dynamic  DNS service on servers running Windows  The Dynamic DNS service  stores that particular IP address in its DNS look up table and  associates it with the name of the system that hosts the RAC  This  action causes problems with Active Directory under Windows  The  default value for a RAC s internal PPP IP address is  192 168 234 235  but the address can be changed by the use
25. ex  omconfig  CLI commands that contain multiple set operations    have been modified to avoid the above problem  If  while executing a  CLI command you receive the message  Error  Illegal combination of    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     parameters   please modify your command into several simpler commands   Each command should change only one setting       When running Server Administrator on a system with a Traditional  Chinese operating system  the Server Administrator pages are  displayed in Simplified Chinese  To view Server Administrator in  English  go to your browser language preference page and change  the language to English       When a log file is saved from Server Administrator  it is saved in zip  format  For best results  it is recommended to open this zip file using  WinZip  Using the Windows Server 2003 or Windows XP embedded   Compressed  zipped  Folder  utility is not recommended       After configuring BIOS settings on certain systems  a second  reboot may be required for updated BIOS settings to be properly  displayed by Server Administrator       If you import an invalid root certificate into Server Administrator  using  Preferences  gt  General Settings  gt  Web Server  gt  X 509  Certificate  and try to log in to Server Administrator after  restarting the Web server  you get a blank page     To correct this issue  you must restore your original  keystore db   file before importing a valid roo
26. ffline  is selected  a check displays to the left of the option  on the  File  menu       If Internet Explorer prompts you to  Work Offline    Connect   or   Try Again   always select  Connect  or  Try Again   Do not select   Work Offline          When setting dates in the  Asset Information  section of the Server  Administrator home page  the current time is appended to the date     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     When setting dates with the CLI  the appended time is noon       If Network Adapter Teaming is installed and enabled on your system   Server Administrator does not display the IP address or other  connection related data for the individual network adapters  The  connection status and IP address belong to the virtual adapter  created by the teaming software       On some systems  temperature probe values and settings are only  supported for whole degrees  not tenths of a degree  On these  systems  setting a fractional value for the minimum warning  temperature threshold results in the set value being rounded down  to the next whole number value  This behavior may cause the minimum  warning threshold to have the same value as the minimum failure  threshold       Mozilla based browsers  including Firefox  share states  including cookies and  browser session information  across multiple instances of running browsers  under the same login session  If a user  or root user  has logged in to  multiple Mozilla Fire
27. form the following  actions in Server Administrator on Windows 2003 for x64 systems  with Internet Explorer 6 Service Pack 1     1  Go to System   gt  Logs    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     2  Select  Command    Alert   or  Hardware    3  Click  Save As   4  Click  Open  in  File Download  message box     Additionally  the  Export  function in the Server Administrator   GUI may not work  The root cause of both problems is the same    To resolve the issue  uncheck  Do not save encrypted pages to   disk  under Tools  gt  Internet Options  gt  Advanced tab  For more  information  see the following article on the Microsoft website    http   support microsoft com default aspx   scid kb en us 8 12935     http   support microsoft com default aspx scid kb en us  141582    and  http   support microsoft com default aspx  scid kb en us  144876        When running Server Administrator  crypt32 dll errors may be written  to the OS Application Event log  This issue occurs due to the   Update Root Certificates  component  which is installed by default  as part of Windows Server 2003 installation  For more information  on this component and reasons for errors  see the  following articles on the Microsoft website      http   www microsoft com technet prodtechnol windowsserver2003   technologies security ws03mngd 04_s3cer mspx      http   support microsoft com default aspx scid kb en us 3 17541     There are two options to avoid thes
28. fox browser instances  then the session management shows  only one session  the last session logged in  of that user  If a user initially  logs in to OMSA with certain privileges  and then starts another instance of  the browser and logs into that instance with higher privileges  the initial  OMSA session with the lower privileges will be elevated to the higher  privileges of the second OMSA session automatically and vice versa       If a user closes the browser using browser close button or logs off from the OS   the Server Administrator session does not get terminated  This session will be  listed in the Session Management page until the session time out occurs or  DSM SA connection service is restarted or the OS is rebooted  The maximum  number of Server Administrator sessions at a time is configured by  connections   entry in   lt OpenManagelnstallPath gt  iws config iws ini  file       If a user changes the operating system timezone to a new timezone  Server  Administrator session management will not display the time in the new timezone  specified  Server Administrator needs to be restarted so that the correct  timezone time is displayed in the session management page       Server Administrator Auto Recovery feature may execute configured  action when system is under heavy stress     The Auto Recovery feature can be set to execute an action  e g   reboot system  to recover a hung system  Since the Auto Recovery  timer is now an application level timer instead of a kernel
29. gt  Run  and then typing  cmd exe   Attempts to  run the CLI commands from the DOS command  command com  may produce  unpredictable results       The DSM SA Connection Service might hang on system startup if both  Oracle and VERITAS R  Backup Exec TM  are installed on the  system  To manually start the DSM SA Connection Service on a system running  Windows  click  Start  gt  Programs  gt  Administrative Tools  gt  Service    and  then right click  Secure Port Server  and select  Start      ISSUES FOR SERVER ADMINISTRATOR RUNNING ON MICROSOFT WINDOWS 2003  OPERATING SYSTEMS      Warning messages   A provider  omprov  has been registered in the  WMI namespace  Root CIMV2 Dell  to use the LocalSystem account   This account is privileged and the provider may cause a security  violation if it does not correctly impersonate user requests    may be displayed after installing Server Administrator  These  messages can be ignored as the Managed Object Format file used to  register the provider   omprov   states that the provider only reads  the inventory data  it does not perform any functions on the server  that require user impersonation   139526       When running Server Administrator on Windows 2003 Small Business  Server Edition  the  Export  function will display the export file  in the browser window  instead of prompting the user to  open  or   save  the export file       An error message   The compressed  zipped  folder is invalid or  corrupted   will be displayed when you per
30. hat you use  the Red Hat Network  RHN  service to update your system software with  the latest update package before deploying your system  Go to  www redhat com to access the RHN service and download updates       Invalid  Format and Check Consistency  options are displayed  for a regenerating virtual disk  When a physical disk in a virtual  disk is rebuilding  the virtual disk changes to a  Regenerating   state  The Format and Check Consistency operations should not  be performed on a virtual disk that is in a Regenerating state   However  the task drop down menu for a Regenerating  RAID 1 concatenated virtual disk may display the  Format and  Check Consistency  options  Dell is working to resolve this  problem       If a physical disk in a RAID 1 concatenated virtual disk fails   the virtual disk is in a  Degraded  state  Rebooting the system  may cause the virtual disk to change to a  Failed  state yet the  virtual disk is still fully operational and can be restored to   OK  status once a functional physical disk is added back to the  RAID 1 set  Dell is working to resolve this problem     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM       Using the Storage Management Service  Advanced Create VDisk Wizard   might occasionally result in a vertical scrollbar of less than  normal width  If this occurs  resizing the Server Administrator  window causes the vertical scrollbar to be redrawn correctly       Tf a virtual disk  using the G
31. he following Dell PowerVault system  NX1950     Added support for Microsoft Virtual Server on the service console     Added support for VMware ESX Server 3 0 on the service console     NOTE  Dell OpenManage installation with VMware ESX Server software  requires special steps  See the VMware Systems Compatibility Guide  located in the Resource Center at www dell com vmware to determine   the versions of ESX Server software compatible with this release of   Dell OpenManage  Each ESX Server release from Dell has an associated  Dell VMware ESX Server Deployment Guide  also posted at this Web  location  Instructions for installing supported versions of Dell  OpenManage available at the time of that ESX Server release are   found in that ESX Server release s Deployment Guide       Added support for Health rollup for the Storage Management Service       Auto refresh of progress for the following Storage Management operations   rebuild  clear  initialize  BGI Init  reconfigure  check consistency   format  initialize  and slow init       For Storage Management Service     array disk    is renamed to    physical disk        Server Administrator Session Management support  GUI Only        Server Administrator home page FRU tab has been renamed as  System Components  FRU        Diagnostics is no longer available through Server Administrator   To run diagnostics on your system  install Dell PowerEdge  Diagnostics from your Dell PowerEdge Service and Diagnostic  Utilities CD or download an
32. he following warnings have been investigated by Dell  engineering and are determined to be  false positives     invalid security warnings  that you can safely ignore        The Web server on 1311 allows scripts to read sensitive  configuration and   or XML files   Dell has determined that this  warning is a false positive       The Web server on 1311 allows to delete     which implies that  the Web server will allow a remote user to delete the files in  root on the server   Dell has determined that this warning is a  false positive       The Web server on 1311 might be susceptible to a  WWW Infinite  Request    attack   Dell has determined that this warning is a false  positive       It is possible to make the remote thttpd server execute arbitrary  code by sending a request like  GET If Modified Since AAA      AAAA  Solution  If you are using thttpd  upgrade to version 2 0  If you  are not  then contact your vendor and ask for a patch  or change  your Web server  CVE on this one is CAN 2000 0359   Dell has  determined that this warning is a false positive       Enabling Integrated Windows Authentication in Internet Explorer  is not required to activate the Single Sign On feature       Server Administrator security settings are not applicable for Active  Directory users  Active Directory users with read only login can  access Server Administrator  even after access is blocked in the  preferences page of Server Administrator     file    T  htdocs SOFTWARE svradmin 5  1 en read
33. me readme_sa txt  10 23 2012 1 31 47 PM       Dell SNMP MIB Files for PowerEdge Systems    Dell SNMP MIB files for PowerEdge systems allow customers to obtain  and verify information provided by supported software agents  The  current MIB files supported by PowerEdge software agents are located  at   support mib  on the  Systems Management Consoles  CD     NOTE  A MIB II compliant  SNMP supported network management station  is required to compile and browse MIB files       On certain systems  user defined thresholds set under Server  Administrator become the default thresholds after uninstalling  Server Administrator     After you change the threshold value of a probe on certain systems  running Server Administrator and then uninstall Server Administrator   the changed threshold value becomes the default threshold value       When modifying the warning threshold settings  the values are stored  in the firmware as discrete integer values and scaled for display   If the modified value is not a discrete integer  it may change when  saved       Fan redundancy can have the following states     Fully Redundant  The sensors display this status  if all the fans  in the system are present and are in a non failure state     OR    Redundancy Lost  The sensors display this status  whenever any  system fan fails or is removed from the chassis     Additionally  on PowerEdge 6800  the sensors will report a fan  redundancy status of  Redundancy Lost  in the following scenarios       A power 
34. n named RACPORT to communicate between the  operating system and the RAC  When any modem is added to the system   the operating system automatically creates a virtual fax  device icon in the printers folder  The fax icon is not used by the  RAC and can be deleted or ignored       The mouse movement on a local Windows system may appear jerky  and erratic during DRAC III console redirection  This behavior  is evident especially when using menus or opening windows       Resizing the Windows desktop to a resolution of 640 x 480 causes  some information to not be visible in the browser window when using  the RAC Web based interface  This issue occurs in Internet Explorer   To view a screen in its entirety when using a resolution  of 640 x 480  you must enlarge the browser window       While installing applications such as SQL Server 2000  if the RAC  device  PCI Function 0  PCI Function 2 and RAC Virtual  UART Port  is disabled and the RAC service is running  you may  experience problems such as an application hang  To successfully  install these applications you can either re enable the driver else    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     you can stop the service  129915       While installing the Dell OpenManage systems management applications  through the Nautilus File Manager  you must use the  Run  button and  not the  Run In Terminal  button after choosing the  start sh   script from the File Manager s file list  Use the 
35. r  This  issue is a known problem  and there is an article and a hot fix  available from Microsoft  The Knowledge Base article number is  Q292822  Downloading the hot fix and implementing the steps in the  article solve the problem       If you have used the  Systems Management Consoles  CD version 3 1   or earlier  to install RAC management station software on any system  running a Windows operating system  you must remove any previous  versions of the RAC management station software before installing a  later version of the RAC management station software     To remove the RAC management station software on Windows  perform    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     the following steps   1  Insert the  Systems Management  CD into the CD drive   2  When the installation application starts  click  Exit    3  Open a command shell window   a  Click the  Start  button  and then click  Run      b  In the  Run  dialog box  type the following command and then  press  lt Enter gt      cmd    4  Start the Install Shield uninstallation program to remove  software     a  In the command shell window  type the following line   replacing x  with the actual drive letter of your CD drive   such as d       x  rac20 mtpkg setup exe  b  Select  Remove   and then click  Next    c  Click  OK    d  Click  Finish    5  Close the command shell window       On systems running Windows  the RAC installation process requires a  virtual modem connectio
36. s Service  in Server Administrator     Download the DRAC 5 readme from support dell com for the latest  information about all known issues     Download the DRAC 5 readme from support dell com for the latest  information about all supported web browsers and managed server    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     operating systems      DRAC 5 support on SUSE Linux Enterprise Server  version 10  is limited  to the Manage Node and to the CLI only  DRAC 5 does not support the Out  of Band GUI on the Management station      DRAC 5 GUI supports Mozilla Firefox 1 0 7 only  32 bit       DRAC 5 GUI supports only 32 bit browser editions     Download the DRAC 4 readme from support dell com for the latest  information about all known issues       Perform the following steps if you do not see the  Remote Access  Controller  properties tab in the Server Administrator user  interface  after installing it on a system with DRAC 4    1  Make sure that the  Remote Access  service is running     2  Refresh the Server Administrator user interface     If the  Remote Access Controller  properties tab still  does not appear       Close the Server Administrator user interface      Restart the  DSM SA Data Manager  service      Restart the  Secure Port Server  service      Open the Server Administrator user interface and log in      When connecting to a remote DRAC 4 using a Mozilla Web browser from  a Linux client  the Virtual Media feature may not
37. ssue has been resolved in Red Hat Enterprise Linux 4 Update 2       In the initial release of Red Hat Enterprise Linux 4  the SNMP  daemon will time out when walking the network configuration section  of the MIB II tree on systems running the Intel EM64T operating system   This results in missing data while trying to manage this server using  Dell IT Assistant  This issue can be fixed by updating  net snmp libs 5 1 2 11 EL4 6 found in Red Hat Enterprise Linux 4  Update 3       For systems running a supported Red Hat Enterprise Linux operating  system  kernel driver messages such as  AAC_ChardevOpen  are  sometimes displayed in the console at the login prompt  These  messages are displayed in the console when the driver initialization  is delayed by the installation of Server Administrator services and  can be safely ignored     ISSUES FOR SERVER ADMINISTRATOR RUNNING ON SUSE LINUX ENTERPRISE  SERVER OPERATING SYSTEMS      On systems running SUSE Linux Enterprise Server 9 SP3  an incorrect  IP address for the system may be displayed in SNMP applications   There is a bug in net snmp 5 1 3 1 0 6 RPM and earlier versions  where the SNMP daemon provides an incorrect SNMP response to a  request for a network interface address  For example  if a network  interface has an IP address of 192 168 1 1  the SNMP daemon will  provide an IP address of 192 168 1 1 0 0 0 0  This may have adverse  affects when trying to manage the system and may affect Dell IT  Assistant operations     To avoi
38. supply is removed and a power supply fan blank is not  inserted     A power supply fan blank is present but failed  134157       If a system with memory redundancy enabled enters a  redundancy  lost  state  it may not be apparent which memory module is the  cause  If you cannot determine which DIMM to replace  see the   switch to spare memory detected  log entry in the ESM system  log to find which memory module failed       If you run Server Administrator while the system is in OS Install  Mode  memory may be reported incorrectly by Server Administrator   To avoid this issue  you must disable OS Install Mode before  running Server Administrator     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM       If you have to uninstall and reinstall the operating system SNMP  service  then reinstall Server Administrator as well  so that the  Server Administrator SNMP agents are registered with the operating  system SNMP agent       Server Administrator Device Drivers for Linux    Server Administrator includes two device drivers for Linux  Dell   Systems Management Base Driver  dcdbas  and Dell BIOS Update Driver   dell_rbu   Server Administrator uses these drivers to perform its   systems management functions  Depending on the system  Server  Administrator loads one or both of these drivers if required    These drivers have been released as open source under the GNU   General Public License v2 0  They are available in Linux kernels   from kernel
39. t certificate  To restore the   keystore db  file  you must use both the basic operating system  commands and the Server Administrator CLI  Perform the following  steps from your operating system command line     1  Type   omconfig system webserver action stop    2  Locate the  keystore db bak  file  The default path is   C  program files dell SysMgt iws config        3  Copy  keystore db bak  to  keystore db    4  Type   omconfig system webserver action start      A temperature that drops below a minimum failure threshold does not  cause a system reset even if this alert action is set       A reporting error  for the amount of memory enabled  may exist for  the Level 2  L2  cache memory when you view  Processor interface   for PowerEdge 6600 and 6650 systems  It may be incorrectly displayed  as 256 K     If you purchased more than 256 K of L2 cache with your system  all  of the L2 cache you have installed is fully enabled  The reporting  error will be corrected in a future BIOS release for PowerEdge 6600  and 6650 systems     file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM       Clicking the browser  Back  and  Refresh  buttons may not display  the correct page with respect to the Server Administrator component  tree  tabs  tab menus  or help as Server Administrator has been  designed with limited functionality to reduce overhead  Full feature  capabilities of the web browser such as  Back    Refresh   and   Open in New Window  may not
40. temporarily during the  swapping  The cfgLanNetworking group is configured using the   racadm config  command  132894     Download the readme for your RAC type from support dell com for  the latest information about all known issues       Remote Access Dial Up Settings  If you change a DRAC III modem   Dial Mode  setting to  Tone  or  Pulse  using Server Administrator   IT Assistant displays the opposite setting       Server Administrator user interface and commands related to  local  authentication enable  are not applicable for RAC firmware 3 20   The Active Directory authentication feature replaces  local  operating system authentication  feature in this version of  firmware  Due to this change  the following commands will return  errors      racadm localauthenable    omconfig rac authentication       Due to the fluctuations in the watchdog timer  the  Last Crash  Screen  may not be captured when the Automatic System Recovery is  set to a value less than 30 seconds  To ensure correct functioning  of the Last Crash Screen feature  set the System Reset Timer to at  least 30 seconds       The cfgDNSServerl and cfgDNSServer2 properties of group    cfgLanNetworking may be set to identical values while swapping  addresses  Some performance may be lost temporarily during the    file    T  htdocs SOFTWARE svradmin 5  1 en readme readme_sa txt  10 23 2012 1 31 47 PM     swapping  The cfgLanNetworking group is configured using the   racadm config  command  132894       The remote ac
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Información técnica  User Manual  Trendnet TU2-700  Aquasplash - Multipure.com  Laser distance meter    CE 200EP IM_FR.qxd - Electrocomponents  Zest™ Nasal Mask Masque Nasal Zest™ Máscara Nasal Zest™ 1 3      Copyright © All rights reserved. 
   Failed to retrieve file