Home
Datalogic Scanning DS4600A-2XX5 User's Manual
Contents
1. 10 mil High for 0 30 mm 12 mils codes and 10 mits smaller 0 Standard for 0 50 mm 20 mils codes and greater 2 50 Code Reading Conditions Standard 4 100 Parameter selectable in WinHost 6 150 8 200 10 250 in mm DATALOGIC DS4600A QUICK GUIDE DS4600A 32XX Short Range 0 2 4 6 8 10 12 14 16 18 20 in 0 40 80 120 160 200 240 280 320 360 400 440 480 520 mm 10 240 8 200 0 20 mm 8 mils 160 6 0 25 mm CONDITIONS 120 ie Code Interleaved 2 5 and Code 39 4 PCS 0 90 80 Pitch angle 0 2 Skew angle 15 49 70 30 mm Tilt angle 0 12 mils SW Resolution High 0 0 2 40 Parameter selectable in WinHost 80 4 120 6 160 g 200 240 10 mm in 10 DATALOGIC DS4600A QUICK GUIDE User Interface RS232 PC side connections 1 13 6 9 14 25 9 pin male connector 25 pin male connector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagram shows a simple test cable including power external push button trigger and PC R
2. 80 120 160 200 240 280 320 360 400 440 480 520 mm 240 8 200 0 50 mm 20 mils 160 CONDITIONS 6 0 60 mm Test Codes used Interleaved 2 5 and 120 24 mils Code 39 4 PCS 0 90 80 Pitch angle 0 2 40 Skew angle 10 gt 0 80 mm Tilt angle 0 31 mils SW Resolution Low 9 2 40 Parameter selectable in WinHost 80 4 120 6 460 g 200 240 10 mm in DATALOGIC DS4600A QUICK GUIDE CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angle 18 Tilt angle 0 Code Resolution High for 0 30 mm 12 mils codes and smaller Standard for 0 50 mm 20 mils codes and greater Code Reading Condition Standard Parameter selectable in WinHost DS4600A 2X1X Raster R1 0 2 4 6 8 10 12 14 16 18 20 22 in 0 50 100 150 200 250 300 350 400 450 500 550 mm 10 250 0 30 mm 12 mils 8 200 0 50 mm 20 mils 6 150 4 100 2 50 0 25 mm 10 mils 0 0 2 50 4 100 6 150 8 200 10 250 in mm CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew angle 18 Tilt angle 0 Code Resolution High for 0 30 mm 12 mils codes and smaller Standard for 0 50 mm 20 mils codes and greater Code Reading Condition Standard Parameter selec
3. Range 0 2 4 6 8 10 12 14 16 18 20 22 in 0 50 100 150 200 250 300 350 400 450 500 550 mm 10 250 0 30 mm CONDITIONS 8 200 12 mils Code Interleaved 2 5 or Code 39 0 50 mm PCS 0 90 20 mils Pitch angle 0 6 150 Skew angle 15 Tilt angle 0 4 100 Code Resolution 2 50 0 25 mm High for 0 30 mm 12 mils codes and 10 mils smaller 0 0 Standard for 0 50 mm 20 mils codes and greater 2 50 Code Reading Condition Standard 4 100 Parameter selectable in WinHost 6 150 8 200 10 250 in mm DATALOGIC DS4600A QUICK GUIDE DS4600A 22XX Short Range 0 1 2 3 4 5 6 7 8 9 10 1 in 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 mm 5 120 4 100 80 3 CONDITIONS 60 Code Interleaved 2 5 or Code 39 2 PCS 0 90 40 Pitch angle 0 1 0 20 mm 0 30 mm Skew angle 10 20 8 mils 12 mils Tilt angle 0 o O SW Resolution High 4 20 Parameter selectable in WinHost 40 2 60 3 80 4 7100 120 mm in DS4600A 22XX Short Range 0 2 4 6 8 10 12 14 16 18 20 in P 0 40
4. in bezug auf elektromagnetische Vertr glichkeit und Produktsicherheit entsprechen Basado en la aproximaci n de las leyes de los Pa ses Miembros respecto a la compatibilidad electromagn tica y las Medidas de seguridad relativas al producto Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti This declaration is based upon compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf da das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con las siguientes normas EN 55022 CLass A ITE AUGUST 1994 LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE AMENDMENT A1 CLASS A ITE OCTOBER 2000 CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT ITE EN 61000 6 2 OCTOBER 2001 ELECTROMAGNETIC COMPATIBILITY EMC PART 6 2 GENERIC STANDARDS IMMUNITY FOR INDUSTRIAL ENVIRONMENTS Le foco Bevo lo Ruggero Cacioppo Quality Assurance Laboratory Manager Lippo di Calderara 08 09 2005 821000693 Rev D
5. not necessary to open the device There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed The laser beam can be switched off through a software command see also the WinHost Help On Line _ a AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE CAUTION CLASS 3B LASER LIGHT WHEN OPEN AVOID EXPOSURE TO BEAM DATALOGIC S p A Via Candini 2 40012 LIPPO DI CALDERARA BO ITALY Model No Serial No Volt Amp Manufactured This product conforms to the applicable requirements of 21CFR1040 at the date of manufacture LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAXIMUM OUTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630 680 nm TO EN 60825 1 2001 Warning and device class labels The laser diode used in this device is classified as a class 3B laser product according to EN 60825 1 regulations and as a Class Illb laser product according to CDRH regulations As it is not possible to apply a classification label on the laser diode used in this device the following label is reproduced below LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT MAX OUTPUT RADIATION 30 mW EMITTED WAVE LENGTH 630 680 nm TO EN 60825 1 2001 Laser diode class label Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode 30 mW at 630 to
6. 128 Code 93 Codabar Pharmacode Up to four header and four terminator characters 30 Vdc 25 mA Voltage max Current Consumption Operating Modes On Line Automatic Serial On Line Test max Outputs Configuration Modes OUT1 OUT2 optocoupled OE or OC Through menus using WinHost utility Host Mode commands from one of the serial ports 40 Vdc 40 mA continuous Vcg max Code Selection Collector Current Up to six different codes during one reading phase max Vcg Saturation 130 mA pulsed 1V at 10 mA max Power Dissipation 90 mW at 40 C max Ambient temp Operating OPTICAL FEATURES Temperature Parameter Storage Non volatile internal EEPROM ENVIRONMENTAL FEATURES 0 to 40 C 32 to 104 F 2XX5 30 22 F to 40 C Light Source Semiconductor laser diode Storage Wavelength 630 to 680 nm Temperature Safety Class Class 2 EN 60825 1 CDRH Humidity max 20 to 70 C 4 to 158 F 90 non condensing USER INTERFACE Vibration Resistance LED Indicators IEC 68 2 6 test FC Ready Good Read External Trigger Data TX 14 mm 2 to 10 Hz 1 5 mm 13 to 55 Hz 2 g 70 to 200 Hz 2 hours on each axis PHYSICAL FEATURES Shock Resistance IEC 68 2 27 test EA Dimensions 101x84x42 mm 4x3 3x1 7 in 30g 11 ms 3 shocks on each axis Weight 615g 22 oz Protection Class IP65 DATALOGIC D
7. 680 nm DATALOGIC DS4600A QUICK GUIDE Model Description DS4600A X XXX YY Decoding Mode Reading Range 2 Standard w Display 0 Medium Range 0 Linear 3 Advanced Code Reconstruction 1 Long Range 1 Raster R1 2 Short Range 2 Raster R2 The following table displays each version s reading performance Version 200 mm 8 in 980 mm 39 in on 1 00 mm 40 mils codes 160 mm 6 in 540 mm 21 in on 0 50 mm 20 mils codes 50 mm 1 97 in 400 mm 15 75 in on 0 80 mm 31 mils codes 200 mm 8 in 970 mm 38 in on 1 00 mm 40 mils codes 160 mm 6 in 540 mm 21 in on 0 50 mm 20 mils codes 120 mm 4 7 in 310 mm 12 2 in on 0 30 mm 12 mils codes Reading Distance Technical Features Optic Version Max Code Resolution Special Features 0 Standard 5 Integrated Heater mm mils 0 50 20 0 25 10 0 20 8 0 50 20 0 25 10 0 20 8 Speed scans s 800 800 809 809 ELECTRICAL FEATURES SOFTWARE FEATURES Model XXX0 10 30 Vdc Model 2XX5 24 Vdc Model XXX0 6W Model 2XX5 12W RS232 RS485 Full Duplex RS485 Half Duplex Power Supply Readable Codes Power Consumption max Main Serial Interface RS232 1200 to 115200 Auxiliary Interface Baudrates Inputs External Trigger IN1 IN2 Headers and optocoupled NPN or PNP Terminators EAN UPC including Add on 2 and Add on 5 Code 39 2 5 Interleaved Code 128 EAN
8. 85 RTX485 RX232 RX485 RTS232 TX485 RTX485 CTS232 RX485 SGND Main SGND Main SGND Main DATALOGIC DS4600A QUICK GUIDE Mechanical Installation COO 5 DATALOGIC DS4600 DS4600A _ o2 l 147 Mounting hole depth M4 X5 The quote refers to the scan line Overall dimensions for 2XXX Models Input Output Connections Open Collector DS4600A 25 pin USER INTERFACE Vext 40 Vdc max Output open collector connections Vcg max 40 Vdc max 40 mA continuous NPN DS4600A 25 pin Vext 30 Vdc max USER INTERFACE Input NPN command using external power PNP DS4600A 25 pin Vext 30 Vdc max USER INTERFACE Input PNP command using external power au aod 0 90 The quote refers to the scan line Overall dimensions for 3XXX Models Mounting Bracket Dimensions NPN DS4600A 25 pin USER INTERFACE Signal Input NPN command using DS4600A power PNP DS4600A 25 pin USER INTERFACE Signal Ground Input PNP command using DS4600A power DATALOGIC DS4600A QUICK GUIDE Connectivity Point to point layout DS4600A Main Serial Interface Auxiliary Serial Interface Local Echo RS232 External Trigger for On Line Mode Pass through layout Multiplexer layout Main Serial Interface RS232 Auxilia
9. DATALOGIC DS4600A QUICK GUIDE General View DS4600A 3XXX Models Figure A n Cable with 25 pin Connector D External Trigger LED Laser Beam Output Window Good Read LED 9 Accessory Mounting Holes 9 Ready LED Warning Label Warning and Classification Labels Mounting Holes G1 Keypad 6 Data TX LED 2 Display For further details on product installation see the complete Installation Manual available on the WinHost CD included with this product Power Supply This product is intended to be installed by Qualified Personnel only Models DS4600A XXX0 This device is intended to be supplied by a UL Listed Direct Plug in Power Unit marked Class 2 rated 10 30 V minimum 0 60 A This device may also be supplied by a UL Listed Power Unit marked Class 2 or LPS power source which supplies power directly to the scanner via the 25 pin connector Model DS4600A 2XX5 This device is intended to be supplied by a UL Listed Direct Plug in Power Unit marked Class 2 rated 24 V minimum 0 50 A This device may also be supplied by a UL Listed Power Unit marked Class 2 or LPS power source which supplies power directly to the scanner via the 25 pin connector WEEE Compliance b Laser Safety The scanner is classified as a Class 2 laser product according to EN 60825 1 regulations and as a Class II laser product according to CDRH regulations For installation use and maintenance it is
10. S232 COM port connections 25 pin D sub male 9 pin D sub female Power Supply VS 10 30 Vdc Power GND Test Cable for DS4600A 11 DATALOGIC S p A Via Candini 2 40012 Lippo di Calderara 05 Bologna Italy dichiara che declares that the d clare que le bescheinigt daf das Ger t declare que el DS4600A XXXX Laser Scanner e tutti i suoi modelli and all its models et tous ses mod les und seine modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate are in conformity with the requirements of the European Council Directives listed below sont conformes aux sp cifications des Directives de l Union Europ enne ci dessous der nachstehend angef hrten Direktiven des Europaischen Rats cumple con los requisitos de las Directivas del Consejo Europeo segun la lista siguiente 89 336 EEC EMC Directivee 92 31 EEC 93 68 EEC emendamenti successivi and further amendments et ses successifs amendements und sp teren Ab nderungen y succesivas enmiendas Basate sulle legislazioni degli Stati membri in relazione alla compatibilit elettromagnetica ed alla sicurezza dei prodotti On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety Bas e sur la l gislation des Etats membres relative la compatibilit lectromagn tique et la s curit des produits ber die Ann herung der Gesetze der Mitgliedsstaaten
11. S4600A QUICK GUIDE Accessories Description Part Number Name C BOX 100 200 Connection Box 93ACC1510 93ACC 1520 C BOX 300 310 Connection Box Profibus 93A301000 93A301030 Connection Box DeviceNet 93A301010 93A301040 90 Reading Device 91D081000 Oscillating Mirror 93A251030 20 mA Current Loop Interface Board 93A151022 Electrical Connections DS4600A is equipped with a cable terminated by a 25 pin female D sub connector for connection to the power supply and input output signals GND and SGNDs Main and Aux are internally connected through filtering circuitry which AN Do not connect GND and SGNDs Main or Aux to different external ground references can be permanently damaged if subjected to voltage drops over 0 8 Vdc CAUTION The details of the connector pins are indicated in the following table 25 pin D sub female connector pinout Power supply input voltage a Power supply input voltage CHASSIS Chassis Ground VS External Trigger supply voltage EXT TRIG External Trigger EXT TRIG External Trigger IN1 Input 1 IN1 Input 1 IN2 Input 2 IN2 Input 2 SUITS Output 1 ERES OUT1 Output 1 OOOOOOOCOOOOO OUT2 Output 2 25 14 OUT2 Output 2 RXAUX Auxiliary RS232 TXAUX Auxiliary RS232 SGND Aux Signal Ground Auxiliary interface GND Power Supply Voltage Reserved Reserved 25 pin female connector RS485 RS485 Full Duplex Half Duplex TX232 TX4
12. ry Serial Interface RS232 External Trigger for On Line Mode Main Serial Interface RS485 Half Duplex Auxiliary Serial Interface Local Echo RS232 GExternal Trigger for On Line Mode RS232 Master slave layout DS4600A ive Slave Ec va S EN NG RS485 Master slave layout 7 DS4600A DS4600A Master 000 la DS4600A Master Main Serial Interface Slaves RS232 only Auxiliary Serial Interface RS232 GExternal Trigger for On Line Mode Auxiliary Serial Interface RS232 Main Serial Interface RS485 Half Duplex GExternal Trigger DATALOGIC DS4600A QUICK GUIDE Reading Diagrams DS4600A 210X Long Range 0 4 8 12 16 20 24 28 32 36 40 in 0 100 200 300 400 500 600 700 800 9001000 mm 16 400 CONDITIONS Code Interleaved 2 5 or Code 39 12 300 PCS 0 90 Pitch angle 0 8 200 Skew angle 15 Tilt angle 0 3 A00 0 50 mm 20 mils Code Resolution 0 0 60 mm 24 mils Standard for 0 50 mm 20 mils codes 0 80 mm 31 mils and greater 1 00 mm 40 mils Code Reading Condition 4 100 Standard 8 200 Parameter selectable in WinHost 42 300 16 400 in mm DS4600A 200X Medium
13. table in WinHost DS4600A 2X2X Raster R2 0 2 4 6 8 10 12 14 16 18 20 22 in 0 50 100 150 200 250 300 350 400 450 500 550 mm 10 250 0 30 mm 12 mils 8 200 0 50 mm 20 mils 6 150 4 100 2 50 0 25 mm 10 mils 0 0 2 50 4 100 6 150 8 200 10 250 in mm DATALOGIC DS4600A QUICK GUIDE DS4600A 31XX Long Range 0 4 8 12 16 20 24 28 32 36 40 in 0 100 200 300 400 500 600 700 800 9001000 mm 16 400 CONDITIONS Code Interleaved 2 5 and Code 39 12 300 Pitch angle 0 Skew angle 15 8 200 Tilt angle 0 4 100 Code Resolution E mm e mis Standard for 0 50 mm 20 mils codes 0 00 mm 25 mis and greater 0 80 mm 31 mils Code Reading Conditions Standard 4 100 1 00 mm 40 mils Parameter selectable in WinHost 8 200 12 300 16 400 in mm DS4600A 30XX Medium Range 0 2 4 6 8 10 12 14 16 18 20 22 in 0 50 100 150 200 250 300 350 400 450 500 550 mm 10 250 0 30 mm 12 mils CONDITIONS 9 2209 0 50 mm Code Interleaved 2 5 and Code 39 20 mils PCS 0 90 6 150 Pitch angle 0 Skew angle 15 4 100 Tilt angle 0 2 50 0 25 mm Code Resolution