1. Model No 320 48293 CAUTION Read understand and follow all Safety Rules and Operating Instructions in this Manual before using this product Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www craftsman com e WARRANTY e SAFETY e DESCRIPTION e OPERATION e APPLICATIONS e MAINTENANCE e TROUBLESHOOTING OPERATION cont POWER BUTTON AND LCD DISPLAY Press the Power button to turn the LCD display screen on When the screen first comes on the temperature is displayed in Fahrenheit for about 2 seconds to indicate if level is being used in optimum operating temperature range The current angle of the level is then displayed and a picture of that angle is shown either above or below the line for true level see Fig 2 An arrow on the display indicates if the level has to be moved up or down True level is reached when the two lines are together and the angle shows 0 see Fig 3 Turn off by pressing and holding the button in for about 2 seconds If not used for 5 minutes the level automatically turns off The LCD display is large and easy to read When the level is turned upside down the LCD screen senses and changes to read correctly in the inverted position TO USE THE LEVEL FOR HORIZONTAL AND PLUMB MEASUREMENTS Horizontal and Plumb measurements can use both the bubble vial and the LCD readout features HORIZONTAL Use the level on horizontal surfaces to true them up
2. Laser On Demand Button Located on the right endcap of the level powers the laser on off Laser Light Aperture The laser beam is emitted from this opening which is on the left endcap of the level Integrated 24 Ruler Located on the lower front surface of the level 24 inches in increments of 1 16 inch with first inch marked in 1 32 inch increments Encased Bubble Vials The level or plumb of a surface can also be accurately measured by positioning the bubble inside the vial in between the marks on the vial s surface The highly sensitive vial ensure the digital level has an accuracy of 0 029 Working Base The bottom of the level is the working base The working base should always be placed firmly on the working surface Magnetic Bottom Four magnets in the working base allow for secure contact to metal handy when working with steel studs or metal ductwork 1 4 inch Tripod Threaded Hole Allows level to be mounted to Craftsman tripod 9 48278 sold separately Battery Compartment Holds two AAA batteries to power Laser Trac system and LCD display Endcaps Ends cushioned to help protect level from damage Large Soft grip Handles For ease in carrying holding level in place OPERATION cont ALIGNMENT TO USE LEVEL WITH TRIPOD Figs 10 11 and 12 This level can be used with a tripod 9 48278 sold separately to project a beam for level up to 300 ft away This feature is perfect for home improve
3. beeper sounds at level 0 45 and plumb 90 To turn sound off simply push button again Current Reading Hold Button Push to hold the information on the current reading The level will hold nine different consecutive angle readings in its memory Memory Recall Button Push button to recall the last 9 measurements that are stored in the memory They will read in order of the latest measurement entered as first Zero Button Absolute relative angle conversion button for comparison of two work surface angles When the level is turned on it is in absolute angle mode Take a measurement of the first work surface The LCD screen indicates the angle between the surface and true level Press the zero button for the relative angle mode and the level will set the current angle to zero Move the digital level to the second work surface and the level will give the relative angle between the first and second surfaces To return to absolute angle again turn power button off and back on Conversion Button By pushing this button you can convert angles to different units Push to change the display units from degrees to pitch in ft to percent slope Pitch readings are in 1 8 inch feet increments Plus and minus signs indicate that the pitch is slightly more or less than true level Laser Trac System Shoots a bright 635 665 nanometer laser beam with a useful visibility of up to 300 ft indoors or outdoors
4. The level s bubble vials will show when you have the surface level The bubbles will be exactly in between the marks on the vial Once the Power button is turned on lay the level on the surface you want to level The LCD display will show the surface you are measuring as a line either above or below the true level line and the degree to which the surface is off with an arrow showing whether the surface should be raised or lowered in order to be leveled The LCD display also gives the degree to which the surface is off To level move the surface with the level on it until the two lines on the readout match and the readout says 0 for the angle Fig 3 If the beeper is activated the beeper will sound when the level is at level PLUMB Fig 5 To find the plumb of a work surface lay the digital level against the vertical surface with the plumb bubble vial at the top The surface will be at true plumb when the bubble is positioned exactly between the marks on the vial 10 OPERATION cont PLUMB cont Fig 5 The LCD display shows the surface with the level on it as a line and true plumb as another line either to the left or right of the line for plumb and the degree to with the surface is off with an arrow showing whether to move the surface to the left or right If the beeper button is on the level will beep when true plumb or 90 is reached PITCH Fig 6 The digit
5. and Co Hoffman Estates IL 60179 SAVE THESE INSTRUCTIONS READ ALL INSTRUCTIONS 19 24 inch LEVEL SAFETY INSTRUCTIONS WARNING BE SURE to read and understand all instructions in this manual before using this level Failure to follow all instructions may result in hazardous radiation exposure electric shock fire and or serious personal injury SAFETY PRECAUTIONS FOR LASERS WARNING Use of controls adjustments or performance of procedures other than those specified in this manual may result in hazardous radiation exposure A WARNING The use of optical instruments such as but not limited to telescopes or transits to view the laser beam will increase eye hazard This level has a built in laser light The laser is a Class Illa and emits output power of a maximum 2 5 mW and 635 665 nm wavelengths These lasers do not normally present an optical hazard However DO NOT stare at the beam as this can cause flash blindness A CAUTION The following label is on your tool It indicates where the level emits the laser light BE AWARE of the laser light location when using ALWAYS MAKE SURE that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the laser Laser radiation is Class Illa Laser Product emitted through Complies with 21 CFR parts 1040 10 and 1040 11 AVOID EXPOSURE this aperture Z WARNING LASER LIGHT LASER RADIATION Avoid Direct Eye Exposu
6. understanding The symbol warnings DO NOT by themselves eliminate any danger The instructions and warnings they give are no substitutes for proper accident prevention measures A WARNING BE SURE to read and understand all safety instructions in this manual including all safety alert symbols such as DANGER WARNING and CAUTION BEFORE using this digital level Failure to follow all instructions listed below may result in electric shock fire and or serious personal injury SYMBOL MEANING SAFETY ALERT SYMBOL Indicates DANGER WARNING OR CAUTION May be used in conjunction with other symbols or pictographs Failure to obey this safety warning WILL result in death or A DANGER serious injury to yourself or to others Always follow the safety precautions to reduce the risk of fire electric shock and personal injury Failure to obey this safety warning CAN result in death or Z WARNING serious injury to yourself or to others Always follow the safety precautions to reduce the risk of fire electric shock and personal injury A CAUTION Failure to obey this safety warning MAY result in personal injury to yourself or others or property damage Always follow the safety precautions to reduce the risk of fire electric shock and personal injury DAMAGE PREVENTION AND INFORMATION MESSAGES These inform user of important information and or instructions that could lead to equipment or other property damage if not follo
7. Get it fixed at your home or ours Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME Anytime day or night 1 800 469 4663 U S A and Canada WYAW Sears com VWWW Sears ca Our Home For repair of carry in products like vacuums lawn equipment and electronics call or go on line for the nearest Sears Parts and Repair Center 1 800 488 1222 Anytime day or night U S A only WWwW Sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparaci n Au Canada pour service en francais a domicilio y para ordenar piezas 1 800 LE FOYER C 1 888 SU HOGAR 1 800 533 6937 1 888 784 6427 www sears ca Sears Brands LLC Registered Trademark Trademark Service Mark of Sears Brands LLC Marca Registrada Marca de Fabrica Marca de Servicio de Sears Brands LLC MC Marque de commerce P Marque d pos e de Sears Brands LLC Operator s Manual CRAFTSMAN 24 in Digital Multi function LEVEL with Laser Trac
8. al laser level can be used to measure the pitch of a roof It measures the pitch in inches of rise per foot of run Push the conversion button to change angle to pitch The pitch will be read as inches per foot in 1 8 in increments with a or a sign to indicate if the pitch is above or below the desired measurement ANGLE Fig 7 The digital laser level measures any angle in degrees with up to 0 1 accuracy This can be used to find the necessary angle for many surfaces and when the conversion button is pushed to display angle will tell you the angle and which way it is off of true level If the beeper button is turned on the level will beep at 0 angle 11 24 inch LEVEL OPERATION cont DESCRIPTION cont LCD SCREEN ICONS o Up Down Indicator The zero line 0 indicates the level position Y The arrow indicates the current angle s position either up or down away from the level 0 NN Battery Power Icon Indicates the amount of battery power in the unit Replace batteries when the black power bar disappears Sound Beeper Icon This icon appears on the screen when the beeper function is activated Memory Icon This icon shows when the memory function is being used Level can recall the last nine saved measurements SLOPE Fig 8 The digital laser level measures the slope of a surface in percent This is useful when laying pipe for proper drainage When the conversion button is in the s
9. d nine different readings in its memory To read out the measurements press the Memory Recall button The last nine measurements can be read out beginning with the most recently saved To make a new measurement press the hold button to return to measuring mode USING CONVERSION BUTTON TO CHANGE DISPLAY UNITS The conversion button changes the measurement units from degrees to pitch in ft to slope percent Pitch readings are in 1 8 in per foot increments Plus and minus signs indicate when the pitch is slightly more or less than true level shown on the display The conversion button can be used even when the display is in the HOLD mode This feature is a convenient way to convert angles from one unit to another For example a 5 in ft roof pitch measurement can be converted to 22 6 for setting up cuts on a chop saw ABSOLUTE ANGLE AND RELATIVE ANGLE MEASUREMENTS ABSOLUTE ANGLE MEASUREMENT 1 Lay the digital laser level on a working surface with the base flat against the surface 2 When level power is turned on the display indicates the absolute angle between level and working surface The zero line indicates the level position and the arrow indicates the direction of the working surface either above or below level 3 To activate the beeper push the beeper button The beeper will sound when the level is at 0 level 45 and 90 plumb To deactivate beeper push button a second time 4 To save the m
10. e the Laser Trac Level for any purpose other than those outlined in this manual This could result in serious injury For further information regarding lasers refer to ANSI Z136 1 the STANDARD FOR THE SAFE USE OF LASERS available from the Laser Institute of America 407 380 1553 ALWAYS USE two AAA size batteries Use of any other batteries may create a risk of fire INSERT the batteries correctly Match the polarities positive to positive and negative to negative as marked inside battery compartment DO NOT short battery terminals DO NOT MIX old and new batteries If batteries are weak replace both of them with two new batteries These new batteries should match each other in brand and type Remove dead batteries immediately and dispose of them according to your local ordinance NEVER dispose of batteries in fire Keep batteries out of reach of children They are not playthings Remove batteries and store separately if level will not be used for several days Do not attempt to repair or disassemble the laser level If unqualified persons attempt to repair this laser product serious injury may result Any repair required on this laser product should be performed by authorized service center personnel 24 inch LEVEL 18 SAFETY SYMBOLS The purpose of safety symbols is to attract your attention to possible dangers The safety symbols and the explanations with them deserve your careful attention and
11. easured angle in memory press the hold button This level can remember the last nine measurements To display the data in memory press the memory recall button to recall recorded angles The level will read out the data starting with the most recent measurements and going backwards to the earliest in its memory 5 To take a new measurement press the hold button to return to measurement mode RELATIVE ANGLE MEASUREMENT 1 Lay the digital laser level on the First working surface 2 Turn on the level The LCD screen indicates the absolute angle between true level and the working surface 3 Press the ZERO button to enter relative angle measurement mode The current angle will be considered to be 0 0 and the display will read 0 0 4 Place the digital level on the Second working surface and the relative angle between the First working surface and the Second working surface will be displayed The zero line indicates the First working surface position and the arrow indicates the direction of the Second working surface either above or below the First working surface level 5 At this point you can change the display units for the measured angle from degrees to pitch inch foot or slope by pressing the conversion button 15 24 inch LEVEL DESCRIPTION cont KNOW YOUR LEVEL cont 3 10 11 12 13 14 15 16 17 18 Sound On Off Button Used to activate the beeper When button is pushed
12. lope mode it will display the surface being measured in percent with exact level at 0 0 If the beeper button is turned on the level will beep at 0 0 TECHNICAL SPECIFICATIONS Class Illa Max output power lt 2 5 mW Power Supply Angle Measuring Range Optimum Operating Temperature OPERATION BATTERY INSTALLATION Fig 4 This multi function digital laser level uses two AAA batteries sold separately to power both the LCD module display and the Laser Trac features LASER TRAC ALIGNMENT Fig 9 This digital level contains a laser diode located inside the left endcap of the level It provides a bright 635 665 nanometer beam with a useful visibility that extends up to 300 ft indoors or outdoors 1 To activate the Laser Trac press in the Laser On Demand Button located on the right endcap of the level Fig 9 2 The center of the laser beam is 1 3 8 inch above the bottom working surface of the level Remember to account for this when doing layouts and taking measurements 3 Level the work surface and the laser will project the level up to 300 feet away to enable you to level large areas This range is only applicable at night or dark environment LASER ON OFF NOTE Always turn off the level before installing or replacing the batteries AVOID EXPOSURE Laser radiation In emitted through this aperture 4 The laser projects a round dot on the targeted su
13. ment projects such as aligning pictures chair rails and other wall fixtures plumbing runs and many other uses 1 Adjust the tripod to true level using the bubble vial on the base of the tripod 1 4 in Threaded 2 Adjust the height of the laser line you want to project 3 Screw the level to the tripod using the 1 4 in threaded hole located in the center of the working surface of the level see Fig 10 4 Make any final adjustments to tripod and level to find the true level point This will be at 0 on the LCD display screen and if activated the beeper will beep 24 inch LEVEL
14. ndable service Use the digital LCD readout for all your angle measurements and layout jobs such as roof pitches saw cut angles and drainage slopes Use the Laser Trac laser beam to extend a visual leveling line over distances much greater than a traditional bubble vial beam level Use the level manually hand held or mounted on a Craftsman tripod 9 48278 sold separately Use the digital level inside or outside to measure pitch in inches of rise per foot of run Measure in degrees with up to 0 1 accuracy Measure any slope in percent measure level and plumb with either the LCD digital display or with the vertical and horizontal bubble vials NOTE Install 2 AAA 1 5 volt batteries sold separately to power both the LCD module display and the Laser Trac laser beam features of this digital level See Battery Installation on page 0 1 Power Button Press the button to turn the LCD display screen on When the LCD screen first comes on the temperature is displayed in Fahrenheit for about 2 seconds The current angle of the level is then displayed and a picture of that angle is shown either above or below the line for true level see Fig 2 An arrow on the display indicates which direction to move the level True level is reached when the two lines are together and the angle shows 0 see Fig 3 Turn off the level by pressing the button and holding it in for about 3 seconds The level will shut itself off when not
15. r diode is damaged i Service Center Reinstall batteries with correct polarity The LCD screen will not turn on Batteries are installed incorrectly Battery voltage is low Replace with new batteries Take tool to Sears Service Center The LCD screen is damaged 16 SAFETY INSTRUCTIONS cont SAFETY PRECAUTIONS FOR LASERS cont D 6 10 11 12 13 14 15 16 17 18 19 20 21 DO NOT operate the Laser Trac level around children or allow children to operate the tool Serious eye injury could result ALWAYS turn the Laser Trac level off when not in use Leaving the tool on increases the risk of someone inadvertently staring into the laser beam DO NOT operate the Laser Trac Level in combustible areas such as in the presence of flammable liquids gasses or dust DO NOT use on surfaces such as sheet steel that have a shiny reflective surface The shiny surface could reflect the beam back at the operator Be aware that laser light reflected off a mirror or any other reflective surfaces can also be dangerous DO NOT attempt to modify the performance of this laser device in any way This may result in a dangerous exposure to laser radiation ALWAYS use only the accessories that are recommended by Sears for use with the Laser Trac Level with this product Use of accessories that have been designed for use with other laser tools could result in serious injury DO NOT us
16. re DO NOT stare into beam Only turn laser beam on when the level is on the work surface Class Illa laser 1 DO NOT remove or deface any product labels Removing product labels increases the risk of exposure to laser radiation 2 DO NOT stare directly at the laser beam or project the laser beam directly into the eyes of others Serious eye injury could result 3 DO NOT place the Laser Trac level in a position that may cause anyone to stare into the laser beam intentionally or unintentionally Serious eye injury could result 4 DO NOT use any magnifying optical tools such as but not limited to telescopes or transits to view the laser beam Serious eye injury could result 4 ACCESSORIES Tripod There is a Craftsman Tripod 9 48278 that can be use with your 24 inch level It has a 4 in threaded screw that fits the 1 4 in threaded screw hole on the level Visit your local Sears store or other Craftsman outlets or shop sears com craftsman 17 24 inch LEVEL DESCRIPTION KNOW YOUR LEVEL Fig 1 Encased LCD Display Screen Bubble Vial Laser On Demand Button Encased Bubble Vial Battery Soft Grip Handles Fig 1a CRAFTSMAN 9 10 11 12 13 14 15 hnbaba abbol THTTTTOROTRUTTOTRTOT TT ATRTTATTITRTITRTR IA TTTRTTTT OPERATION cont CURRENT READING HOLD BUTTON AND MEMORY RECALL To hold the information of the current reading press the Hold button The level can hol
17. rface The dot size and shape may change slightly with distance temperature or target surface material The point to use is the center of the dot pattern 1 Open the battery cover located in the right endcap of the level below the laser on off button see Fig 4 2 Insert two new AAA alkaline batteries with the polarity as indicated on the inside of the battery compartment 3 Close the cover securely in place 12 24 inch LEVEL OPERATION cont ALIGNMENT TO USE LEVEL WITH TRIPOD cont Figs 10 11 and 12 5 The laser projects a dot on the targeted surface see Fig 12 and the size and shape may vary according to temperature distance and target surface material ALWAYS use the center point of the dot for your measurement Rotate the level on the tripod to align chair rail pictures etc 360 around the space Fig 12 paren N 14 DESCRIPTION cont KNOW YOUR LEVEL cont NOTE Before attempting to use your level familiarize yourself with all of the operating features and safety requirements This Craftsman 24 inch Digital Level is a highly versatile leveling tool designed for fast easy operation Heavy duty lightweight aluminum construction with the LCD digital module constructed of unbreakable ABS polymer that s sealed against dirt and water and the toughest acrylic block bubble vials and solid state laser components all add up to on the job durability and long depe
18. used for 5 minutes 2 LCD Display Large easy to read display screen reads right side up even when level is upside down Fig 2 Fig 3 24 inch LEVEL MAINTENANCE This digital laser level has been designed to be a low maintenance tool However in order to maintain its performance follow these steps 1 HANDLE the tool with care Treat it as a precision optical device such as a camera or binoculars 2 AVOID exposing the tool to shock continuous vibration or extreme hot or cold temperatures 3 STORE the tool indoors and in a safe place 4 The Level is designed to be weather resistant and construction site tough If the level is splashed with mortar or other construction site residue simply wipe clean with a damp cloth DO NOT immerse the level in water 5 Aluminum surfaces can be cleaned with a non abrasive powder 6 Check the batteries regularly to avoid corrosion REMOVE the batteries from the tool if it is not going to be used for an extended period 7 DO NOT try to take the level apart TROUBLESHOOTING Replace with new Laser point batteries projection is weak Batteries are low in power Check to make sure the switch is in the On position Laser On Demand Switch is not On Laser point is not projected Reinstall batteries with correct polarity Batteries are installed incorrectly Replace with new batteries Battery power is low Take tool to Sears Lase
19. wed Each message is preceded by the word NOTE as in the example below NOTE Equipment and or property damage may result if these instructions are not followed 24 inch LEVEL TABLE OF CONTENTS OMI A E E E E E E EE A EEE Page 2 Safety Oy MOONS cine dacaancaderaateattaieacsecsesdnacwbadntahenacehentadcnsbedins Page 3 Safety WINSTONS siusis a e aeai Page 4 5 WI SSCHOUOM nicicsnticaedaasseeeandvedsesbondpdcncaweosciedwcis bheSedesiestumetanatiene Page 6 9 OPa ae een ee eee ene ee eee eee eee ee Page 9 15 PAD IO NCAONGS secre iec ccecscceanoe catesareecsenscderstadeugteesecaheneastasnerecae Page 10 12 Manton aNG esre r E E E EA E EEA Page 16 Troubleshooting ncactuetanertesnuctaasnatacescieneceneademuinend tocnenonadneseas Page 16 PCCOSSOMCS os wreciscictnncesitatinns vantmathiciins nnctnitsidndtnlesitned caateellcuameuans viiauencieinamse Page 17 Sears Repair Parts Phone NUMDEISS cccccseceeeeeceeeeseeetaness Back Cover ONE YEAR FULL WARRANTY ON CRAFTSMAN TOOL If this Craftsman tool fails to give complete satisfaction within one year from date of purchase RETURN IT TO ANY SEARS STORE OR OTHER CRAFTSMAN OUTLET IN THE UNITED STATES FOR FREE REPLACEMENT If this Craftsman tool is used for commercial or rental purposes this warranty applies for only 90 days from the date of purchase This warranty gives you specific legal rights and you may also have other rights which vary from state to state Sears Roebuck