Home

Cooper Lighting QCT1785 User's Manual

image

Contents

1. Model QCT901 with QCT1875 Fixture Mounting Con t Window Ceiling Thickness Indicator Mark Mudding Frame ooooo0oo0o000000 000000000000 Q 58 amp 000000 0000000 000000000000 oco00000000000 eo00000000000 C00000000000 8 32 Flathead Screw Figure 2 Mudding Frame Fixture van Mudding Frame Bracket Flathead Screw Ceiling Mudding Compound Drywall Tape Fixture Gap Ball Detent Catch Trim Mechanism Figure 3 RSA Lighting 7945 Orion Ave Van Nuys California 91406 Trim Installation 1 Connect Safety Cable attached to Banana Bracket on Trim Mechanism See Fig 1 amp Fig 5 to Fixture by inserting Safety Cable through opening in Fixture and inserting Snap Hook See Fig 5 on end of Safety Cable into hole in Bracket attached to inside of Fixture Housing Cover See Fig 1 2 Install Trim Mechanism into Fixture by pressing firmly to seat Ball Detent Catches See Fig 3 Lamp Installation Lamp Bracket accommodates from one 1 to three 3 accessories 1 Remove Trim Mechanism from Ceiling 2 Slide out Lamp and or Accesories from under Bracket Arm to remove See Fig 4 3 Replace Lamp and or Accessories as necessary Lamp i Accessory 1 Accessory 2 Bracket Arm Accessory 3 Trim Mechanism Figure 4 Visit our web site at www rsalighting com 818 349 3030 800 356 3030 FAX 818 349 3031 INSTALLATION INSTRUCTIONS CON T vgo040r QUIET CEILING SQUARE TRIM BASED SERIE
2. LIGHTING INSTALLATION INSTRUCTIONS vooosor QUIET CEILING SQUARE TRIM BASED SERIES Model QCT901 with QCT1875 Avoid Fire or Electric Shock Installation Instructions for qualified electricians only Install per National Electrical Code and local regulations Read Installation Instructions completely before installation Failure to follow Installation Instructions may void warranties Fixture Mounting BUTTERFLY MOUNTING 1 Fixture comes equipped with Universal Butterfly Mounting Brackets and can take common 1 inch or 1 1 2 inch Black Iron or Galvanized Mounting Channels Supplied By Others See Fig 1 2 Position Fixture so the Mounting Channels lie on top of ceiling runners 3 Fasten Mounting Channels securely to ceiling runners 4 Secure Mounting Channels to Universal Butterfly Mounting Brackets with wire tire downs HANGER BAR MOUNTING 1 Maximum Hanger Bar rafter span 22 1 2 inches 2 Spread Hanger Bars to fit span of rafters 3 Hammer Flanges to seat Hanger Bar Tabs in rafters See Fig 1 4 Secure Hanger Bars using one 1 nail in Mounting Hole in each Flange 5 Mudding Frame is sent unmounted from factory Adjust Mudding Frame to applicable Ceiling thickness 1 2 5 8 3 4 1 by rotating in 90 increments until desired Ceiling Thickness Indicator Mark shows through Window in Mudding Frame See Fig 2 6 Secure Mudding Frame using four 4 8 32 x 1 2 inch Flathead Screws for 1 2 inch 5 8 inch a
3. S Model QCT901 with QCT1875 LIGHTING o i Hot Aiming 90 Rotational Lamp Adjustment Hot Aim Lamp with power ON for precise aiming 1 Remove Trim Mechanism from Fixture 45 Degree Angular adjustment can be achieved without removing Trim Mechanism 2 Loosen Lock Knob 3 Rotate Rotational Adjustment Ring until Lamp is in desired position 1 With power ON and Trim Mechanism in place Insert Phillips Head I Ngumi prsi l PRR using Angle Indicators for reference 4 Tighten Lock Knob 5 Replace Trim Mechanism into Fixture Screwdriver through Hole or Slot in Trim into Bearing Funnel See Fig 5 2 To re aim Lamp turn 6 32 Flathead Screw to desired position using visual Angle Indicators on Banana Bracket See Fig 5 Rotational Adjustment Safety Cable Ring Trim Mechanism Snap Hook Angle Indicators Rotational Adjustment Ring Lock Knob Banana Bracket Lock Knob Angle Indicators Figure 6 Bearing Funnel 6 32 Flathead Screw Philips Head Screwdriver Figure 5 Visit our web site at www rsalighting com RSA Lighting 7945 Orion Ave Van Nuys California 91406 818 349 3030 800 356 3030 FAX 818 349 3031
4. nd 3 4 inch Ceiling thickness or four 4 8 32 x 3 4 inch Flathead Screws for 1 inch Ceiling thickness RSA Lighting 7945 Orion Ave Van Nuys California 91406 Dus Fixture Mounting Con t 7 Adjust elevation of Fixture so Mudding Frame Edge will be flush with surface of finished Ceiling by loosening two 2 1 4 inch Hex Screws on both Universal Mounting Brackets See Fig 1 8 Tighten two 2 1 4 inch Hex Screws on both Universal Butterfly Mounting Brackets to secure Fixture See Fig 1 9 Install Ceiling drywall up to Mudding Frame on Fixture so that the two 2 Mudding Frame Brackets on Fixture contact inside of Ceiling See Fig 3 10 Retain Fixture to Ceiling with one 1 Flathead Screw through each of two 2 Mudding Frame Brackets See Fig 3 11 Apply Drywall Tape and Mudding Compound to Mudding Frame overlapping Mudding Frame Flathead Screws Fixture Gap and surrounding area Feather out Mudding Compound from Mudding Frame opening to surrounding ceiling area to produce a smooth flat finish See Fig 3 Safety Cable Fixture Housing Cover Bracket Mounting Channel Supplied By Others 1 4 Hex Screw Universal Butterfly Mounting Bracket ES Hanger Bars Mudding Frame Mounting Hole Trim Mechanism Figure 1 Visit our web site at www rsalighting com 818 349 3030 800 356 3030 FAX 818 349 3031 INSTALLATION it LIGHTING INSTRUCTIONS CON T voooaor QUIET CEILING SQUARE TRIM BASED SERIES

Download Pdf Manuals

image

Related Search

Related Contents

FORUM DES MÉTIERS ET DES FORMATIONS Samedi 08 février 2014  Origin Storage 1TB MLC SATA 2.5"  Samsung BD-E6300 Kasutusjuhend  Samsung Monitoimilaite Mustavalkolaser SCX-4833FD Käyttöopas    Guideline - WordPress.com  AUTOMATHIC DISH POWDER 食洗機パウダー  CHRONOPRINTER 540 User`s Manual  共通取扱説明書  お客さまのために  

Copyright © All rights reserved.
Failed to retrieve file