Home

Cooper Lighting Metalux VT3-254T5 User's Manual

image

Contents

1. 2 End Watertite Hubs all Watertite Hubs have 1 2 Conduit Entry SSL Stainless Steel Latches SHIPPING INFORMATION Catalog No Wt VT3 132 DR WL 16 Ibs VT3 232 DR WL 16 Ibs VT3 154T5 16 Ibs VT3 254T5 16 Ibs ADF071376 Specifications and Dimensions subject to change without notice Metalux Customer First Center 1121 Highway 74 South Peachtree City GA 30269 e TEL 770 486 4800 FAX 770 486 4801 10 06 2008 11 40 01 AM
2. providing maximum protection and rigidity Ballasts are CBM ETL Class P certified suitable to 70 F Cold temperature ballasts are available for less than 0 F starting with EHT T5HO only EB PLUS and ER PLUS Ballasts Rotor lock lampholders Electrical components and fixtures are UL CUL listed for Wet Locations IP65 approved with optional IP67 rating 4 only with 8 latches Catalog Project Comments Prepared by C Shielding New contemporary styled lens clear acrylic w impact resistant additives and linear prisms DR Clear low brightness pattern acrylic with 15 high impact additive DR 100 Clear low brightness pattern acrylic with 100 high impact additive Example VT3 232DR 100 4 13 16 123mm 6 15 16 177mm LAMP CONFIGURATIONS 4 13 16 123mm R 4 13 16 S 123mm R 6 5 8 168mm 36mm X 5 3 8 137mm PT ee Y 4 3 16 49 13 16 1265mm 107mm INSTALLATION DATA MOUNTING OPTIONAL CHAIN HANGING SET BRACKETS VT2 CHAIN SET U Furnished Includes 6 ft of chain 4 large Two per S Hooks and 4 small S Hooks 4 Unit Order One 1 Kit for each 4 Fixture Four per Two 2 Kits Recommended For 8 Unit 8 Fixture COOPER Lighting www cooperlighting com 4 13 16 123mm X 1 13 32 36mm Y 2 1 2 64mm A X 1 13 32 KTO 6 15 16 177mm X 1 13 32 Y 6 15 16 36mm Y 2 1 2 177mm
3. 39 29 23 18 38 28 22 18 27 22 18 26 21 17 25 20 17 16 9 36 26 20 16 35 25 19 15 24 19 15 23 18 15 22 18 15 13 10 33 23 18 14 32 23 17 14 22 17 13 21 17 13 20 16 13 12 Zonal Lumen Summary Luminance Data Average Average Average Zone Lumens lamp Fixture elo ye Barn sr ie ae ee a o 0 40 2112 24 0 34 4 a a a sla ae ses 65 6126 8631 10102 a _ on a 75 4240 9114 10293 0 180 6137 69 7 100 0 85 2265 7674 8760 WL Wet Label Packaging T8 Electronic Instant Start U Unit Pack apn A Total Harmonic Distortion lt 10 Options No of Ballast 1or2 EB8 PLUS TS8 Electronic Instant Start High Ballast Factor gt 1 13 Total Harmonic Distortion lt 20 No of Ballast 1or2 ER8_ T8 Electronic Program Rapid Start Total Harmonic Distortion lt 10 o of Ballast 1or2 EBT_ T5 Linear Electronic Program Rapid Start Total Harmonic Distortion lt 10 No of Ballast 1or2 EHT_ T5 Linear Electronic Start High Ambient Total Harmonic Distortion lt 10 No of Ballast 1or2 ACCESSORIES Accessories order separately VT2 Chain Set U Chain Hanging Set Includes 6 ft of chain 4 large S Hooks and 4 small S Hooks Order One 1 Kit for each 4 Fixture Two 2 Kits Recommended For 8 Fixtures VT2 SS MBK Stainless Steel Mounting Bracket 8L 8 Latches IP67 Rating M4 Miro 4 Interior Reflector RIF1 Radio Interference Suppressor TH 2 Top Watertite Hubs only no End Hubs TEH 2 Top amp
4. 64mm F WY r 6 15 16 177mm Relative Light Output Factors To accurately predict how luminaires will perform in cold temperatures Cooper Lighting individually tested each configuration in the different ambient environments The relative light output factor should be applied as an additional light loss factor component VT3 Series ee Specifications and Dimensions subject to change without notice 15 F 26 C O F 18 C 20 F 6 C 33 F 0 C 50 F 10 C 91 93 Consult your representative for additional options and finishes VTs 132 232 332 15415 25415 4 INDUSTRIAL 1 2 OR 3 LAMP Vaportite Industrial ENERGY DATA Input Watts EB Ballast amp STD Lamps 132 30 232 61 154T5 54 254T5 106 Luminaire Efficacy Rating LER FI 73 Catalog Number VT3 232DR Yearly Cost of 1000 lumens 3000 hrs at 08 KWH 3 29 Reference the lamp ballast data in the Technical Section for specific lamp ballast requirements Not Suitable for Wet Locations if EL4 Option is added Consult Pre Sales Technical Support LAMPS CONTAIN MERCURY DISPOSE ACCORDING TO LOCAL STATE OR FEDERAL LAWS Be LINEAR DISCONNECT PRI I ey A gt A Safe and convenient means of SRTIF disconnecting power ADF071376 10 06 2008 11 40 01 AM PHOTOMETRICS VT3 232DR UNV Candela EB81 WL U 1 Electronic Ballasts Ang
5. DESCRIPTION COOPER LIGHTING METALUX The VT3 Series is a contemporary looking energy efficient industrial Vaportite fixture that features rugged and durable construction The VT3 incorporates a full metal clear tray inside a reinforced fiberglass housing with a high impact diffuser This Vaportite series is suitable for interior and exterior applications and can be surface or chain mounted The VT3 Series has been designed for maximum operation in commercial institutional and industrial environments where weathering high temperature humidity and dust or corrosive fumes are present SPECIFICATION FEATURES A Construction Fiberglass housing is reinforced polyester and self extinguishing ASTM D635 74 plastic of a permanent pearl gray color Top of housing has five embossments 2 unit nine embossments 4 unit and thirteen embossments 8 unit providing mounting flexibi lity on uneven surfaces A watertite hub for 1 2 conduit entry is provided at each end of housing standard for continuous feed Polyurethane gasketing is formed in the housing providing a continuous seamless seal for the diffuser Six sturdy cam latches clamp diffuser tightly for a positive seal between housing gasketing and diffuser MOUNTING DATA 41 1 2 1054mm Optional Back Hub Locations 38 3 4 984mm 1 4 x 28 Stud 2 Places B Electrical Unit has full metal gear tray secured by internal fasteners and tethers
6. epresentative for availability and ordering information ae COOPER Lighting www cooperlighting com Ballast Type EB8 VT3 VT3 254T5DR UNV Candela T EHT1 WL U 1 Electronic Ballasts Angle Alongil 45 Across L 0 1546 1546 1546 2 54WT5 lamps 5 1540 1525 1533 S al 4400 lumens 10 1519 1548 1525 N Spacing criterion 15 1483 1514 1546 Il 1 2 x mounting 20 1436 1509 1566 l height 1 1 5 25 1375 1487 1530 se ie ales am 30 1300 1446 1509 f mounting height 35 1215 1396 1502 j aoua a Efficiency 69 7 40 1118 1315 1425 j 45 1012 1267 1384 uw Test Report 50 896 1174 1308 S LTL107771ES 55 770 1081 1179 60 634 954 1107 LER FL59 65 496 827 1101 Yearly Cost of 1000 70 352 771 1044 lumens 3000 hrs at 08 KWH 4 05 a T 90 13 285 431 Coefficients of Utilization Effective floor cavity reflectance 20 rc 80 70 50 30 10 0 rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 O RCR 0 82 82 82 82 80 80 80 80 76 76 76 72 72 72 69 69 69 67 1 74 70 66 63 72 68 65 62 65 62 59 61 59 57 58 57 55 53 2 66 60 55 50 64 58 54 49 55 51 48 53 49 46 50 47 45 43 3 60 52 46 41 58 51 45 41 49 44 40 46 42 39 44 41 38 36 4 55 46 40 35 53 45 39 34 43 38 33 41 36 33 39 35 32 30 5 50 40 34 29 48 40 33 29 38 32 28 36 31 27 34 30 27 25 6 46 36 29 25 44 35 29 24 34 28 24 32 27 24 31 26 233 22 7 42 32 26 21 41 32 25 21 30 25 21 29 24 20 28 23 20 18 8
7. g 0 30 399 158 20 4 in Deg cd sm cd sm cd sm 0 40 1512 26 5 34 3 ais els ue 0 60 2847 49 9 64 5 2 2093 aoe a 0 90 4169 73 1 94 5 aS sical om ams 0 180 4413 774 100 0 ip aom eon al 85 1349 5151 6092 ORDERING INFORMATION SAMPLE NUMBER VT3 232DR UNV EB81 WL U Tandem Blank 4 Length 8T 8 Length Series VT3 Vaportite Number of Lamps 1 2 or 3 Lamps Not included Wattage Length 32 32W T8 48 28T5 28WT5 48 54T5 54W T5HO 48 Voltage 120V 120 Volt 277V 277 Volt 347V 347 Volt UNV Universal Voltage 120 277 UNC Universal Voltage 347 480 a GL Single Element Fuse GM Double Element Fuse EL Emergency Installed Lens DR Internal Prismatic Lens 15 DR High Impact Additive Standard DR 50 50 High Impact Additive High Impact DR 100 100 High Impact Additive Extreme NOTES Products also available in non US voltages and frequencies for international markets 2 Not available when specifying emergencies voltage must be specific 93 Lamp 54WT5HO is recommended for ambient temperatures below 102 F 40 C with EHT2 ballasts and below O F 18 C with EHT1 ballast Emergency option in 3 lamp version must use remote mount test switch Top Hub required when stem mounting For complete product data reference the Fluorescent Specification binder Specifications amp dimensions subject to change without notice Consult your Cooper Lighting R
8. le Alongll 45 Across L 2 32WT8 lamps 0 1103 1103 1103 Sa 5 1097 1108 1107 A i 2850 lumens 10 1083 1107 1106 z Spacing criterion 15 1059 1091 1127 Il 1 3 x mounting 20 1025 1089 1113 ill height 1 15x 25 983 1058 1098 j 30 932 1035 1088 mounting height 35 370 991 1052 Efficiency 77 4 40 801 952 1024 A Test Re 45 725 892 971 se port 50 640 831 920 Bre LTL10864 IES 55 548 753 378 LER FL72 60 451 683 814 65 352 611 771 Yearly Cost of 1000 70 251 550 698 lumens 3000 hrs at 75 155 471 592 08 KWH 3 34 80 17 367 513 85 28 290 427 90 6 217 342 Coefficients of Utilization Effective floor cavity reflectance 20 re 80 70 50 30 10 0 rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 91 91 91 91 89 89 89 89 84 84 84 79 79 79 75 75 75 73 4 82 78 74 70 79 75 72 69 71 68 66 67 65 63 64 62 60 58 2 74 67 61 56 71 65 60 55 61 57 53 58 54 51 55 52 49 47 3 67 58 52 46 65 57 51 46 54 49 44 51 47 43 49 45 42 40 4 61 51 44 39 59 50 43 38 48 42 37 45 40 36 43 39 35 33 5 56 45 38 32 54 44 37 32 42 36 31 40 34 30 38 33 30 28 6 51 40 33 28 49 39 32 27 37 31 27 36 30 26 34 29 26 24 7 47 36 29 24 45 35 28 23 33 27 23 32 27 23 30 26 22 20 8 43 32 25 20 42 31 25 20 30 24 20 29 23 19 27 23 19 17 9 40 29 22 17 38 28 22 17 27 21 17 26 20 17 25 20 16 15 10 37 26 20 15 36 26 19 15 24 19 15 23 18 15 22 18 14 13 Zonal Lumen Summary Luminance Data Average Average Average Zone Lumens lamp Fixture Angle 0 Deg 45 Deg 90 De

Download Pdf Manuals

image

Related Search

Related Contents

GAIA – Graphical Astronomy and Image Analysis Tool  Parametric Finite Element Modeling Across Many  Rexel 12300 folder  The Complete Amiga 600 User Guide  Este equipo ha sido analizado y se encontró con que cumple con    2004 LEGACY SERVICE MANUAL QUICK REFERENCE INDEX  MSI Gaming GT70 0ND-1005FR (Dragon Edition)  NetOp School 5.5 Student  USER MANUAL  