Citizen refch-60-2b User's Manual
Contents
1. CITIZEN INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CH 602B IDENTIFICATION 0F PARTS Systolic blood pressure display section Diastolic blood pressure Pulse display section Start switch Power switch SPECIFICATIONS Measuring method Indication Measuring range Accuracy Inflation Deflation Exhaust Memory function Power source Battery life Rated voltage Working temp amp humidity Storage temp amp humidity Left wrist circumference Outside dimensions Weight Electric shock protection Accessories Oscillometric system Digital display Pressure 0 280mmHg Pulse 40 200 beat min Pressure 3mmHg Pulse 5 Automatic inflation by internal pump Automatic constant speed deflation system Quick exhaust by electromagnetic valve One data 2 pcs AAA LRO3 alkaline batteries Approx 250 times LRO3 once a day 180mmHg room temp 22 C 3V DC 10 C 40 C 30 to 8596 RH 20 C 60 C 10 to 9596 RH 13 5cm 19 5cm 74mm W x 31mm D x 72mm H Approx 140g including batteries Type B equipment 2 pcs AAA LRO3 alkaline batteries Instruction manual Storage case Specifications and designs may be changed without notice in the event of improvements being made CLEANING METHOD OF CUFF After cleaning the cuff with a neutral detergent lightly rinse it with machine will cause air leakage Also be careful not to get water int
2. ICmmHg PULSE min PULSE min Place your elbow on a table so that the palm is turned upwards and the cuff center is as high as your heart Relax your entire vb body SYSTOLICmmHg DIASTOLICmmHg 3c id 3 To Start the Measurement LL PULSEIin J When inflation is completed the automatically exhaust mecha nism will gradually deflate the pressure in the wrist cuff and the mark 98 will appear indicating that measurement is in progress When a pulse is detected the pressure value moves to the lower side of the display At this time the mark flashes and buzzer beeps If the inflation is insufficient at a pressure of 180mmHg the reinflation is automatically made to a pressure of 210 240 and Press iN SUM Swich TRUE 280mmHg until inflation is suitable for measurement This unit The unit is inflated when the START switch is pressed cannot be inflated over a pressure of 280mmHg Eng 8 Y SYSTOLICmmHg 25 DIASTOLICmmHg Ei PULSE min When diastolic pressure value is detected the measurement is complete Systolic pressure value is displayed on the upper side and diastolic pressure on the lower side of the display Then air in the wrist cuff will deflate immediately and the mark Y appears during deflation SYSTOLICmmHg 25 SYSTOLICmmHg PUL DIASTOLICmmHg ic PULSE min DIASTOLICmmHg LL b5 PULSE min Blood pressure values and pulse rate appear alternativ
3. e of the most important tasks for ensuring proper measurement of blood pressure Wind the cuff around the wrist and tighten it so that one finger may be inserted between the cuff and arm Do NOT measure blood pressure after bathing or drinking When you feel like relieving yourself you should do so before measuring blood pressure Measure blood pressure where the room temperature is about 20 C Do NOT measure blood pressure when it is too cold below 10 C or too hot above 40 C in the room Do NOT measure blood pressure immediately after drinking cof fee or tea or smoking Measure blood pressure with a relaxed and quiet posture Keep the center of the cuff at the level of your heart and do NOT move your arm or talk during measurement Do NOT keep on measuring so many times as your arm will have built up congestion of blood and you will not get a valid reading Eng 3 PRECAUTION FOR USE AND MAINTENANCE Precautions for use f you suffer from heart disease high blood pressure or other cir culatory disease please consult your doctor first f you feel abnormal pressure of the cuff during use or any other irregularity reduce the pressure by immediately switching off the power or removing the batteries and consult the sales outlet where purchased f you think the measured value is abnormal or if measuring makes you feel unwell discontinue use and consult your doctor Measurement of blood pressu
4. ely on the display every approximately two seconds Display of the mea surement result will continue until power is turned off Subsequent Measurements When more than one reading is desired wait at least two min utes between reading in order for the blood at wrist flow to re turn to normal Then press the START switch again Eng 9 Turn Power Off Press the Power Switch to turn OFF Automatic Power Off Function If this unit is left on after measurement an Automatic Power OFF Function turns the power OFF after approximately 3 min utes To continue measurement press the power switch to turn the unit ON DESCRIPTION OF DISPLAY MARKS DISPLAY MARK CONDITION CAUSE CORRECTIVE ACTION A Measurement is begun but the pressure was insufficient Repeat measurement again Appears when the blood pressure could not be measured accu Er r rately Some noises were detected by the movement of arm during measurement Repeat measurement again First exhaust air from the cuff reapply the cuff prop erly and remeasure p n Repeat measurement again Err BT Appears when the pulse could not be measured Appears when the batteries become weak Replace the batteries Device has a trouble Ask purchased shop Eng 10 CITIZEN is a registered trademark of Citizen Watch Co Japan CITIZEN GROUP Consumer Electronics Division CBM Bldg 5F 5 68 10 Nakano Na
5. g national and or local recycling regulations when disposing of the batteries and the products at the end of their useful lives Reference European standard This products complies with EC instructions 93 42 EEC Medical Device Directive and with the following standards EN 1060 1 1995 Noninvasive Sphygmomanometers Part 1 General Requirements and EN 1060 3 1997 Noninvasive Sphygmomanometers Part 3 Supplementary Requirements for Electromechanical Blood Pressure Measuring Systems Manufacturer Name Address Premier Precision Ltd Block E G H 6th floor Phase 2 Yip Fat Factory Building 73 75 Hoi Yuen Road Kwun Tong Kowloon Hong Kong European Representative Name WvW elektronische Ger te Vertrieb GmbH Address Robert Koch StraBe 20 D 80538 M nchen GERMANY C 0086 INSTALLING THE BATTERIES To use this unit you must install batteries and also if battery mark BT3 will appear on the display you must change two pieces of batteries After fastening the under hook close the battery cover e LRO3 batteries or equivalent is suitable for this blood pressure monitor Open battery cover as illustrated Replace the new two pieces of batteries matching the and polarities on each battery with the polarity marks on the case Eng 5 MEASUREMENTS 1 Turn Power On SYSTOLICmmHg 25 DIASTOLICmmHg 3 PULSE min SYSTOLIC nm After all display mar
6. kano ku Tokyo 164 0001 Japan Japan CBM Corporation Phone 03 5345 7430 Fax 03 5345 7431 E mail info con jcbm co jp
7. ks are disappeared the last measured sys tolic and diastolic blood pressure values are displayed Value of the pulse is not memorized nor displayed Memory function works on for approximately one second or during POWER switch is depressed Press the POWER switch to turn on VVA 5 SYSTOLICmmHg Hau SYSTOLICmmHg DIASTOLICmmHg BBB DIASTOLICmmHg PULSE min PULSE min All display marks appear for approximately one second and buzzer beeps If batteries become weak BT 1 mark is appeared and mea surement is discontinued After memorized blood pressure value is disappeared deflation mark w appear for approximately one second Eng 6 SYSTOLICmmHg ri Li DIASTOLICmmHg PULSE min After three short buzzer beeps the 0 appears on the display Then ready for measurement Attaching of Wrist Cuff Wrist cuff Turn left hand palm upwards and wrap the cuff around the wrist so that the display is placed on the side of palm Wrap the wrist cuff on bare skin Wrist circumference 13 5 19 5cm Eng 7 Wrist edge Place the wrist cuff at the 1cm from the wrist edge Wrap the cuff around your wrist securely Wrap the cuff around your wrist securely so that there is no space between the wrist and cuff with the edge of wrist cuff pulled Fold up the rest of unused wrist cuff v SYSTOLICmmHg SYSTOLICmmHg IBU 54 DIASTOLICmmHg DIASTOL
8. o water and let it dry in the air Hard rubbing or washing in a washing the air hose Eng 2 GENERAL REMARKS General Remarks on blood pressure measurement If the cuff is to be deflated quickly depress POWER switch The attached cuff is suited for a wrist circumstance of 13 5cm to 19 5cm When attaching the cuff the body of a blood pressure monitor should be placed on the inside of your wrist Self measurement is no therapy In no case may you change the dosage of medication prescribed by your physician In operation for blood pressure measurement you should urinate and should remain relatively still for 10 to 15 minutes prior to measurement Exercise eating and drinking smoking etc prior to measurement may affect the results The blood pressure varies constantly throughout the day Mea surement should be made regularly at the same time each day Do NOT be impressed by the results of one measurement Keep a record of blood pressure variations Many readings tell a story Emotional stress may tend to cause pressure to rise For proper measurement of blood pressure Take a deep breath five or six time and then relax before measur ing blood pressure If you are tense when taking the measure ment you will not get a valid reading Blood pressure will be elevated when you are in a worrisome or irritated state suffering from lack of sleep or constipation or after exercise or a meal Putting on the cuff is on
9. re may not be possible for someone with a weak pulse or arrhythmia Congestion swelling etc may occur in some people f blood pressure is measured repeatedly an accurate result will not be achieved An interval of about 10 minutes should be al lowed The memory is erased if the batteries are removed for replace ment etc and a record should be kept of any necessary data Precautions for maintenance Do NOT store the blood pressure monitor where it will be exposed to direct sunlight high temperature over 60 C low temperature below 20 C high relative humidity over 95 or in a dusty place Do NOT expose the blood pressure monitor to under force or vi bration or drop it Remove the battery batteries when not in use for a long period Do NOT disassemble the apparatus Do NOT bend the cuff or air hose unnecessarily NEVER wipe the blood pressure monitor with thinner or benzene as they may damage it When the monitor is very dirty wipe it clean with a cloth moist ened with Sterilizing alcohol or a neutral detergent and then wipe it with a dry cloth Do NOT use thinner or benzene Eng4 Nature and frequency of maintenance This products is designed for use over an extended period of time however it is generally recommended that it be inspected every two years to ensure proper function and performance Protect the nature environment Please help protect natural environment by respectin