Home
Citizen Systems CHU503 User's Manual
Contents
1. 16 17 18 f you suffer from heart disease high blood pressure or other circulatory disease consult your physician before using the monitor nflating to a higher pressure may result in bruising where the cuff is applied f the cuff pressure feels abnormal or you experience any other irregularity while using the cuff reduce the pressure immediately by pressing the START STOP switch detach the cuff or unplug the air hose connector from the monitor and then consult the sales outlet where you purchased the monitor f you think the measurement is abnormal or if measurement makes you feel unwell discontinue use and consult your physician Blood pressure measurement may not be possible for anyone with a weak pulse or arrhythmia Repeated blood pressure measurement and prolonged overinflation may cause problems such as congestion or swelling in some people Frequently repeated blood pressure measurements will not give accurate results Allow an interval of about 1 minute between measurements f you suffer from a severe problem with blood circulation in your arms consult your physician before using the monitor Failure to do so could be hazardous to your health Measurement may not be possible for anyone with insufficient blood flow to the area where measurements will be taken or who suffers from a frequent irregular heartbeat Consult your physician for advice on whether to use the monitor DO NOT wrap the cuff around an inj
2. 2000 times Accessories Set includes a cuff 4 AA batteries R6P for the monitor Instruction manual Optional Accessories Large cuff 32 0 42 0 cm AC adapter Applied part for this device is Cuff A range in barometric pressure 105 kPa to 70 kPa A range in altitude 300 m to 3000 m Overall system accuracy of this device is met with the requirement of item 7 9 of EN1060 3 EN1060 3 Non invasive sphygmomanometers Part 3 European Standard Eng 20 e CITIZEN is a registered trade mark of Citizen Holdings Co Japan e Design and Specification are subject to change without notice CITIZEN SYSTEMS JAPAN CO LTD 6 1 12 Tanashi cho Nishi Tokyo shi Tokyo 188 8511 Japan E mail sales oe systems citizen co jp http www citizen systems co jp
3. localization Upper Arm Cuff Soft cuff Cuff circumference range 22 0 32 0 cm Pressure 0 to 280 mmHg Measurement range Pulse 40 to 180 pulse min Accuracy Pressure 3 mmHg Pulse 5 of reading Pressure 3 digits Pulse 3 digits Measurement icon Battery icon LCD displays wi Irregular heartbeat IHB indicator Icons Body movement indicator cw Memory icon GG Average indicator g Hypertensinon classification indicator Switch 4 START STOP MEMORY Inflation Automatic inflation by internal pump Deflation Automatic speed deflation system Rated voltage 6V DC SW ZI direct current Exhaust Electromagnetic quick exhaust valve Power supply 4AA batteries R6P LR6 __ Alkaline Approx 500 times 170 mmHg once day Battery duration Manganese Approx 150 times 22 C Use Cuff Automatic power off function Approx 3 min after activated Main unit dimensions 145 W x 76 H x 96 D mm Cuff size Approx 144 x 492 mm i Unit Approx 290g w o batteries Weight Cuff a 7308 Operating conditions Temperature 10C 40C Humidity 30 to 85 RH Storage conditions Temperature 20 C 60 C Humidity 10 to 95 RH Electric shock protection Internal power unit Degree of Protection Type BF applied part Mode of operation Continuous operation Memory 90 readings Average of last 3 readings Service Life 5 years Cuff s Life Approx
4. or pests are not there DO NOT drop the blood pressure monitor or the cuff and subject it to other shocks or vibration Remove the batteries if the monitor will be left unused for a long period DO NOT attempt to disassemble the monitor or the cuff DO NOT bend the cuff or the air hose excessively f the monitor is very dirty wipe it clean with a cloth moistened with a neutral detergent Then wipe it with a dry cloth 7 NEVER clean the blood pressure monitor with alcohol thinners or benzene as his could damage the monitor 8 To clean the cuff wipe it with a moist cloth Avoid hard rubbing as this will cause air leakages Take care also not to get water into the air hose Z Warni g No modification of this device is allowed Symbols Explanation CE ss The CE marking is meant to provide information to market inspectors in the EU member countries Type BF applied part Keep dry Warning Refer to instruction manual before use Appliance compliance WEEE directive Accumulators and battery packs for separate collection Manufacturer mo D oor ao E AAGE 9 3 The device has been tested and homologated in accordance with EN60601 1 2 for EMC This does not A Warning guarantee in any way that the device will not be affected by electromagnetic interference Avoid using the device in high electromagnetic environment Eng5 Nature and frequency of maintenance This product is designed for
5. talk DO NOT measure blood pressure when the cuff has been on your arm for a few minutes or more During this time your arm will have built up a higher blood pressure and you will not get valid reading f the Body movement indicator or Irregular heartbeat IHB indicator is displayed relax and measure your blood pressure again If the Irregular heartbeat IHB indicator appears frequently you are advised to consult a doctor about your health condition q See page 14 Eng 2 10 The National High Blood Pressure Education Program Coordinating 11 Committee has developed a blood pressure standard according to which areas of low and high risk blood pressure are identified This standard however is a general guideline as individual s blood pressure varies among different people and different age groups etc Ref The Seventh Report of the Joint National Committee on Prevention Detection Evaluation and Treatment of High Blood Pressure Complete Report UNC 7 2004 These blood pressure Suspected Stage 2 classifications are based Hypertension on historical data and Systolic gt 160 may not be directly Diastolic 100 applicable to any particular Suspected Stage 1 patient It is important L Hypertension that you consult with I Systolic 140 159 ini E Diastolic 90 99 your physician regularly E Please consult with your Suspected _ physician prior to making 5 Prehypertension any healthcare decision
6. use over an extended period of time however it is generally recommended that it be inspected every two years to ensure proper function and performance Protect the nature environment Please help to protect natural environment by respecting national and or local recycling regulations when disposing of the battery and the product at the end of their useful live WEEE MARK If you want to dispose this product do not mix with general household waste There is a separate collection systems for used electronics products in accordance with legislation under the WEEE Directive Directive 2002 96 EC and is effective only within European Union Information for Users on Collection and Disposal of used Batteries The symbol in this information sheet means that used batteries should not be mixed with general household waste For proper treatment recovery and recycling of used batteries please take them to applicable collection points For more information about collection and recycling of batteries please contact your local municipality your waste disposal service or the point of sale where you purchased the items Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to discard used batteries please contact your local authorities or dealer and ask for the correct method of disposal Note for the battery symbol The symbol might be used in combination with a chemi
7. CITIZEN INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR rer CHU503 English 1301 English _ Contents 2 GENERAL REMARKS 4 PRECAUTIONS FOR USE AND MAINTENANCE 7 IDENTIFICATION OF PARTS 8 LOADING THE BATTERIES 9 REMOVING THE BATTERIES 9 USING AC ADAPTER OPTION 10 TIME ADJUSTMENT 11 MEASURING YOUR BLOOD PRESSURE 15 TIPS FOR OBTAINING ACCURATE MEASUREMENTS 16 CALLING UP THE DATA STORED IN MEMORY 17 KEY TO DISPLAY ICONS 18 ABOUT BLOOD PRESSURE 18 BLOOD PRESSURE Q amp A 19 BEFORE REQUESTING REPAIRS OR TESTING 20 SPECIFICATIONS Ensure that you have all the following components Blood pressure monitor unit Cuff model SCN 008 for monitor 4 AA size batteries Eng 1 OPTION e Large cuff model SCL 005 e AC adapter model AC 230CZ Instruction manual GENERAL REMARKS General remarks on blood pressure and blood pressure measurement Ts 2 To deflate the cuff quickly press the START STOP switch Before applying your blood pressure cuff be sure you have selected the appropriate size cuff Cuff model SCN 003 fits arm circumference 22 32 cm OPTION Large cuff model SCL 005 fits arm circumference 32 42 cm When attaching the cuff adjust the position of the cuff so that the blue marker is located in the center of your arm and the hem of the cuff is 1 2 cm for Cuff 2 3 cm for Large cuff above your
8. EM Measurement in a reclining posture Relax yourself to avoid placing pressure on the cuff Lie down facing the celling Lightly open your hand with palm up and straighten your arm Relax your body arm and fingers Do not move your body or talk during measurement DONO You may use your right arm to measure your blood pressure Blood pressure value is likely to differ by as much as 10 mmHg when measured on the right arm instead of the left or vice versa Measure your blood pressure on the same arm each day Eng 15 90 measurement results can be stored in Memory The average value is calculated automatically to help you manage your daily health 1 Press the m Memory switch once Example of display when the m Memory switch is pressed indicating the average value appears at the bottom of the display Then the average value based on the last three measurements is displayed MYO and the average value do not appear if there are two or fewer measurements stored in memory SYS mate DIA nie mette SYS ce DIA rette If you press the Memory switch again past measurement data are displayed Each time you press the switch the measurement data are displayed in order from the most recent to the oldest You can fast forward the data numbers in display by pressing and holding the Memory switch Example of display when the m Memory switch is pressed SYS one DIA ante ste Th
9. Time Set switch to confirm the setting A Warning The CHU503 and AC 2300Z should be used indoors in dry The year is set and the month indicator blinks location You can fast forward the numbers in display by 1 Insert the AC adapter plug into the socket on the blood pressure pressing and holding Adjust switch monitor 7 mains power 3 Press the Adjust switch to adjust the month outlet Press Adjust switch to increase the number by one 1 Make sure there is no Press e Date Time Set switch to confirm the setting 5 Ag 12 09 obstruction within the The month is set and the day indicator blinks Se immediate vicinity of the AC adapter so that 4 Press the Adjust switch to adjust the day AC adapter AC adapter it can be immediately Press Adjust switch to increase the number by one 1 socket unplugged from the Press e Date Time Set switch to confirm the setting ee ues mains power outlet ka zo i b iD 10 00 2 The day is set and the hour indicator blinks La Plug the AC adapter into a mains power outlet i E A e f you plan to use the AC adapter for an extended period of time remove the 5 Press te Adjust switch to adjust the hour batteries If the batteries are left in the compartment electrolyte may leak from the ress Adjust switch to increase the number by one al batteries and cause a fault in the blood pressure monitor Press e Date Time Set switch to confi
10. asurement as well as the CB The remaining capacity of the batteries is inadequate measurement results Be sure to set the clock after inserting the batteries Set the e Adjust the clock after changing the batteries date first and then the time e The data stored in the memory is not deleted by changing the batteries When you install the batteries for the first time the monitor will display the e Do not use rechargeable batteries clock setting screen You do not need to perform step 1 Proceed to step 2 e Do not use alkaline LR6 and manganese R6P batteries together If you set the clock and change its setting start from step 1 e Batteries included are for demonstration purposes only Battery life may be shorter than specified 1 Press and hold the e Date Time Set switch for N i gt e When disposing of used batteries comply with governmental regulations or approximately two seconds rn 19 environmental public institution s rules that apply in your country area The year indicator blinks T pat 13 T USING AC ADAPTER OPTION 2 Press the Adjust switch to adjust the year A Using the optional dedicated AC adapter model AC 230CZ for the CITIZEN blood Press Adjust switch to increase the number by one pressure monitor CHU503 allows you to measure your blood pressure without The year can be adjusted in the range of 2013 2042 having to worry about the amount of remaining charge in the batteries Press Date
11. cal symbol In this case it complies with the requirement set by the Directive for the chemical involved Reference European standard The blood pressure measuring device corresponds to regulation EN60601 1 EN1060 1 EN1060 3 EN1060 4 Pb Calibration The blood pressure measuring device is generally recommended to have the monitor inspected every two years to ensure correct functioning and accuracy Please contact a distributor Name CITIZEN SYSTEMS JAPAN CO LTD Address 6 1 12 Tanashi cho Nishi Tokyo shi Tokyo 188 8511 Japan European Representative Name WvW elektronische Ger te Vertrieb GmbH C Address Fintelmannstra e 20 Eingang Martin Heydert Stra e 0086 D 14109 Berlin Germany e For technical data please contact our European Representative Eng6 IDENTIFICATION OF PARTS Component names lt Main unit gt lt Cuff gt Air hose Display Blue marker Metal hoop Air hose connector MEMORY switch Adjust switch Air hose socket Date Time set switch Battery compartment See page 8 for the Battery compartment lt Display gt Battery icon Systolic blood E e i H Diastolic blood pressure display aul p p pressure display e a Body movement Average N indicator indicator 4 oi A A kedo aM 3 ulse display 18 08 8 88 og pi Time display Date display Memory icon Irregular heartbeat IHB indicator Hypertension classification indicator See page 14
12. e data number is displayed before the measurement results Eng 16 e The value stored in memory is numbered in the order of measurements For example when 90 sets of data are stored in memory the data number 1 ABOUT BLOOD PRESSURE represents the latest data _ Da Data number 1 2 3 89 90 What 5 blood pressure t t circulates blood throughout your ER a er The latest data The earliest data body Blood is pumped from the heart at a constant pressure into gt gt ee U pressure is Le e arterial blood pressure an HOW TO DELETE THE DATA represents in general terms entricie The artery wall expands your blood pressure Blood 5 x Contraction 1 while pressing the m Memory switch press and hold the START press ur it STOP switch for more than 3 seconds he systolic pressure that occurs when the heart pumps blood and the diastolic All data stored in Memory will be deleted pressure that occurs when blood returns to the heart Press and hold Your blood pressure changes all the time for 3 seconds Your blood pressure differs according to your age gender and a range of other 4 actors It is likely to be affected by your biorhythm during the day and by your Deleted posture physical activities mental activities level of stress and even by the air emperature The blood pressure of a healthy person generally varies within a day Example of blood pressure variations within a day S
13. e measured blood pressure value is displayed according to The Seventh Report of the Joint National Committee JNC7 blood pressure classification 1 See page 3 Systolic CITIZEN mmHg DIA mtg Red Suspected Hypertension Stage 1 Stage 2 140 Yellow Suspected Prehypertension 130 ved U 120 a ur msi Pulse min Blue Normal JNC7 The Seventh Report of the Joint National Committee on Prevention Detection Evaluation and Treatment of High Blood Pressure Eng 14 80 90 mmHg Diastolic AUTOMATIC POWER OFF FEATURE CALLING UP THE DATA STORED IN MEMORY e After taking the blood pressure measurement pressing the START STOP switch will turn the monitor off However if you do not press the switch the monitor s Auto OFF function will automatically turn the monitor off after 3 minutes TIPS FOR OBTAINING ACCURATE MEASUREMENTS Your blood pressure varies according to your posture the time of day and a range of other factors Ideally you should measure your blood pressure in the same posture at the same time every day E Taking measurements while sitting Place your arm on a table or similar surface with your forearm extended t is important to have the cuff level with your heart Open your hand slightly on the table so that your palm is facing up and your ingers are relaxed Do not move your body or talk while aking the measurement
14. elbow Self measurement is not therapy In no event should you change the dosage of your medication prescribed by your physician As preparation for measuring your blood pressure you should urinate and then remain relatively still for 10 to 15 minutes prior to measurement DO NOT place too much emphasis on the results of one measurement Keep a continuing record of your blood pressure variations A complete picture can only be obtained from a large number of readings To obtain correct blood pressure measurements 1 Take five or six deep breaths and then relax before measuring your blood pressure If you are tense when taking the measurement you will not get a valid reading Your blood pressure will be elevated if you are anxious or irritated suffering from lack of sleep or constipation or have just taken some exercise or eaten a meal Wrap the cuff around your arm and tighten it so that one finger can be inserted between the cuff and arm See page 12 DO NOT measure your blood pressure after bathing or drinking easure your blood pressure where the room temperature is around 20 C DO NOT measure your blood pressure when it is too cold below 10 C or 00 hot above 40 C in the room DO NOT try to measure your blood pressure immediately after drinking coffee or ea or after smoking Measure your blood pressure when you are relaxed and still Keep the center of he cuff at the level of your heart and DO NOT move your arm or
15. for the Body movement indicator and Irregular heartbeat IHB indicator Eng 7 LOADING THE BATTERIES Batteries supplied with the unit should be loaded in compartment before you use the blood pressure monitor When you install the batteries for the first time after purchase the monitor will display the clock setting screen Follow step 2 and subsequent steps in TIME ADJUSTMENT See page 10 to set the clock 1 Open the cover of battery compartment Pressing the hook down pull the cover toward you to open Battery compartment Battery cover Hook If the Blood pressure monitor is left unused for an extended period of time the batteries should be removed from the compartment 2 Place batteries in the compartment Put the batteries paying attention to the positive and negative terminal symbols and 4 AA batteries 3 Close the battery cover Fitting the lugs of the cover at the mating recesses of the battery compartment body push the hook to close the cover Fit the lugs projections at the recesses Eng 8 REMOVING THE BATTERIES TIME ADJUSTMENT e When the icon is displayed or nothing appears in the display replace the old Setting the clock enables measurements to be accurately recorded batteries with four new ones All four batteries should be changed at once The monitor can record the date and time of me
16. hat the center of the cuff Press with the time signal on the radio etc to complete clock adjustment comes to the height of your heart When e is pressed to complete clock adjustment the set year and date time appear briefly and then the display switches off Carefully place the cuff on your arm taking care to use the correct tightness The tightness is correct if you can readily slide a finger between the cuff and your arm MEASURING YOUR BLOOD PRESSURE 1 ATTACHING THE CUFF Before applying your blood pressure cuff be sure you have selected the appropriate size cuff Cuff model SCN 003 fits arm circumference 22 32 cm OPTION Large cuff model SCL 005 fits arm circumference 82 42 cm 6 Relax your arm and lightly open your hand with the palm upward Plug the air hose connector into the main unit e Plug the air hose connector firmly into the air hose socket on the main unit 1 Unroll the cuff and thread the end through the as illustrated metal hoop so that the side with the hook and loop fastener is on the outside 2 Put the cuff around your arm so that the blue marker comes to the palm side 3 Adjust the position of the cuff so that the blue marker is located in the Air hose Air hose connector center of your arm and the socket hem of the cuff is 1 2 cm for 7 Cuff 2 3 cm for Large cuff above your elbow Blue marker Place the cuff at the height of
17. ic vio Blood pressure values ui E Phi 7 x DIR san Af E DI Appears when the cuff is Attach the cuff properly and po fera VI MI AN A measured at five minute intervals through the day attached too loose measure again AA ALE DET EEE T ee oH te See page 11 ATTACHING Time of day Bevan AT Honour AJ Stott FH Clin Sci 1969 36 329 44 Appears when the cuff is not THE CUFF attached correctly and the Normal state is restored to the artery wall Dilation A message saying all the data have been deleted from the memory is displayed Pwo 140 KEY TO DISPLAY ICONS DISPLAY MARK CONDITION CAUSE CORRECTIVE ACTION 8 Blood pressure value mm pulse cannot be detected BLOOD PRESSURE Q amp A Unable to measure due to Er r 3 excessive pressure on the Q Why is the blood pressure measured at home different from that measured by the sensor physician or at a hospital Appears when the batteries Replace the batteries A Your Heed pressure may vary ae to exercise the ambient temperature or your A mental state When you have a physician or nurse measure your blood pressure the 2 SED naverun gut ee LOADING THE pressure value is likely to be 10 to 20 mmHg higher than usual due to anxiety and a or stress Knowing what affects your blood pressure helps you to better monitor your Appears when the pulse Attach the cuff proper
18. ly again health rate falls outside the Take deep breaths to rel nd i 7 105 B i oe below 39 ie a Q Why does the blood pressure obtained vary with measurement 6 10 1 30 beats min or above 181 15 TIPS FOR OBTAINING A Our blood dle o aaen oy automate nerve ui Blood esi anors i with every heart beat We are likely to think that our blood pressure is constant bu beats min ACCURATE MEASUREMENT B it varies if you take measurements in repetition Blood pressure is susceptible to the The unit does not function Contact the store where it time of day such as morning and afternoon season and atmospheric temperature properly was purchased or your local In addition blood pressure is easily affected by mental stress or emotional ups and service center See page downs It tends to increase when you feel tension or decrease when you are relaxed 19 BEFORE REQUESTING REPAIRS OR TESTING Eng 17 Eng 18 Q What is the benefit of measuring my blood pressure at home A Blood pressure measurements taken at home give reliable data as they can be taken when you are in a stable and relaxed condition Physicians place considerable importance on blood pressure measurements taken at home You should measure your blood pressure at the same time each day and record the variations in your blood pressure Always consult your physician for an interpretation of your blood pressure A readings and to determine the p
19. rm the setting 6 10 00 e Itis recommended that batteries are in the unit when using the AC adapter If The hour is set and the minutes indicator blinks ae aA there are no batteries in the unit when the AC adapter is disconnected from either A A A P the Adjust switch to adjust th the power outlet or the unit itself date and time settings will be lost 6 cesta IUSESWRST TO ANILSE IE e Plug the AC adapter into the socket where you can easily plug off soon and nn safely in times of trouble Press Adjust switch to increase the number by one lu SA e When disconnecting the AC adapter unplug the AC adapter from the main Press e Date Time Set switch to confirm the setting 6 10 1 30 power outlet and then unplug the AC adapter plug from the socket on the blood The minutes are set and 12 12 hour format blinks pressure monitor The dedicated AC adapter model AC 230CZ for the CHU503 is optional The AC adapter is available from retailers stocking CITIZEN digital blood pressure monitors Eng 9 Eng 10 7 Press the Adjust switch to adjust the time 4 Pull the end of the cuff outwards so that the cuff is format d your arm and The setting switches between 12 hour format 12H Nu snug aroun and 24 hour format 24H each time Adjust switch is lo 4 men Seura Se pressed i Press Date Time Set switch to confirm the setting 12H or 24H 5 Place your arm on a table or the like so t
20. roper treatment BEFORE REQUESTING REPAIRS OR TESTING Make sure to check the following before sending your blood pressure monitor away to be tested or repaired Problem Display stays blank when you press the START STOP switch No measurements can be taken Checks Check whether the batteries are dead Response Replace all the batteries with new ones Check whether the batteries are installed the right way round and oriented correctly Check whether the measurement icon is displayed Load the batteries in the correct direction Attach the cuff properly Check whether the cuff is attached correctly Did you stay calm during measurement Measure your blood pressure again making sure to remain still Note that blood pressure measurement may not be possible for someone with or cardiac arrhythmia irreg an extremely weak pulse ular pulse Your blood pressure readings are abnormally high or low compared with those taken in hospital Te See page 18 If you want to dispose this product do not mix with general household waste There is a separate collection systems for used electronics products in accordance with legislation Eng 19 SPECIFICATIONS Model number CHU503 Measurement system Oscillometric method Display Digital display type Measurement
21. the heart 0 See page 15 The cuff should be put on the bare arm 1 2 cm for Cuff or over a light weight underwear Xx 2 3 om for Large cuff A If you wear a heavy weight top please remove it Eng 11 Eng 12 Press the START STOP switch e All digits displayed is an initial display indicating that the monitor is functioning normal e The cuff is pressurized automatically If the unit judges that pressurization is insufficient it automatically repressurizes N 3 n n 4 U JU gt SU 6 10 4 30 6 10 4 38 6 10 9 30 i x is displayed when a pulse is detected When you want to stop measurement press the START STOP switch The cuff is deflated and measurement stops If the pressurization value exceeds 280 mmHg if pressurization feels abnormal or if you want to stop the measurement process press the START STOP switch again The cuff deflates and the power turns off 5 The measurement results are displayed CITIZEN e Once measurement is complete the SYS mhie DIA mir rrie cuff deflates and the measurement 4 d n g n results systolic diastolic blood LU U pressure values pulse are displayed Provided there is no error in the 6 10 9 30 60 measurement results they are raa Fe En Pukat stored automatically Hypertension classification indicator ES See page 14 O Finishing measurement e Press the START STOP switch to
22. turn the monitor off START STOP switch Eng 13 Manual pressurization e f your systolic blood pressure is expected to exceed 200 mmHg use Manual pressurization when taking a measurement e Keep START STOP switch held pressed until the pressure value you want to stop pressurization is reached approximately 40 mmHg higher than the Systolic blood pressure You can stop pressurization by the unit by releasing the switch at the aforementioned value is reached The upper pressure limit is 280 mmHg display if you move your hand or arm during measurement causing a substantial pressure change to be detected e Ifthe Body movement indicator is displayed measure your blood pressure again The Body movement indicator is displayed on the measurement results A If an irregular heartbeat is detected during measurement the Irregular la heartbeat IHB indicator is displayed after measurement is completed An irregular heart beat is defined as a heart beat that varies by 25 e from the middle of 5 heart beat intervals during the blood pressure measurement e Measurement may not be correct if your heartbeat fluctuates greatly during measurement If the Irregular heartbeat IHB indicator is displayed measure your blood pressure again If the Irregular heartbeat IHB indicator appears frequently ACaution you are advised to consult a doctor about your health condition Hypertension Classification Indicator Th
23. ured arm DO NOT wrap the cuff around an arm in which a drip intravenous infusion is inserted or which is being used for blood transfusion as part of medical reatment Doing so could result in an injury or a serious accident DO NOT use the monitor in the vicinity of flammable gases such as those used or anaesthesia Doing so could ignite the gases and cause an explosion DO NOT use the monitor in enriched oxygen environments such as a hospital s hyperbaric chamber or oxygen tent Doing so could ignite the oxygen and cause a fire DO NOT use mobile phones near the monitor as this could result in a malfunction f you use a Cardiac pacemaker consult your physician before using the monitor Be sure to use this unit only for measuring blood pressure DO NOT use it for any other purpose Be sure to use only our authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit DO NOT use this unit on infants Blood pressure measurement may not be possible for anyone with common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation Eng 4 Maintenance Precautions 1 DO NOT store the blood pressure monitor in locations exposed to direct sunlight high temperatures over 60 C low temperatures below 20 C high relative humidity over 95 or excessive amounts of dust Make sure to store the blood pressure monitor where children pets and
24. v Soole 170 199 based on the device s D reading Your physician will Normal tell you your normal blood Systolic lt 120 Diastolic lt 80 pressure range as well as the point at which you will be considered at risk 80 90 100 Diastolic mmHg gt This unit is equipped an indicator which visually indicates the blood pressure classification Normal Suspected Prehypertension Suspected Stage 2 Hypertension of the result after each measurement Intended Use e This device is noninvasive blood pressure monitor by oscillometric method This device can measure the systolic blood pressure SYS the diastolic blood pressure DIA and the pulse rate automatically e This device is intended to be used for checking personal health condition at ne under the direction of a physician and is not intended to be a diagnostic levice e This device is not intended for use with neonates or infant and not intended for automatic cycling measurement Measure your blood pressure at the same time each day Your blood pressure changes all the time This means that data gathered over a long period has far more significance than data from just one measurement For this reason you must measure your blood pressure on a daily basis Ideally you should measure your blood pressure at the same time each day wherever possible Eng 3 PRECAUTIONS FOR USE AND MAINTENANCE Precautions for use 1 11 12 13 14 15