Home

CHIEF PST16 User's Manual

image

Contents

1. de seguran a Chiave di sicurezza Veiligheidssleutel Cl de s curit PST16 Installation Instructions TOOLS REQUIRED FOR INSTALLATION g lt 3 8 A 1 PST16 2 W Flag extender O ey C 2 10 24 x 1 2 D 2 10 24 F 4 5 16 E 4 5 16 x 2 1 2 Installation Instructions PST16 ASSEMBLY AND INSTALLATION NOTE The PST16 may be mounted to a wood 2 x 4 stud wall 16 on center The PST16 has a lateral shift of 1 after attachment to stud wall IMPORTANT If the installation of this product requires OSHPD seismic approval refer to the OSHPD pre approval documents and drawings before beginning installation OSHPD documents and drawings are available at www chiefmfg com and located on the PST16 product information page Mount Assembly Optional 1 Insert flag extender B slot into top of right latching flag 2 Attach using 10 24 x 1 2 Phillips undercut machine screw C and one 10 24 nylon locknut D See Figure 1 3 Repeat with left latching flag See Figure 1 Using a stud finder locate and mark the two studs to which the PST16 will be installed Use a nail as a temporary mount and hang the PST16 on the wall using the triangular hole in the center of the PST16 See Figure 2 Level the PST16 and mark the four mounting holes See Figure 2 Remove the PST16 from
2. pis Segno a matita Potloodmerkteken Marquage au crayon Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis pointe cruciforme Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Open Ended Wrench Llave de boca Gabelschl ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche Remove Quitar Entfernen Remover Rimuovere Verwijderen Retirez By Hand A mano Von Hand Com a mao A mano Met de hand la main Optional Opcional Optional Opcional Opzionale Optie En option d y d Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabe a sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale Security Wrench Llave de seguridad Sicherheitsschl ssel Chave
3. the wall Flag extender slot Figure 1 Mount Installation WARNING IMPROPER INSTALLATION CAN LEAD TO DISPLAY FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component 1 Identify a suitable wall location for the PST16 taking into consideration the display size Figure 2 WARNING ELECTRICAL SHOCK HAZARD CUTTING OR DRILLING INTO ELECTRICAL CORDS OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surface is free of electrical wires and cables before drilling or installing fasteners WARNING EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surface is free of gas water waste or any other plumbing before cutting drilling or installing fasteners Using a 7 32 drill bit drill four 2 1 2 deep pilot holes ensuring they are centered on the studs See Figure 3 Fasten PST16 to wall using four 5 16 x 2 1 2 lag bolts E and four 5 16 flat washers F See Figure 3 PST16 Installation Instructions k 4 7 32 x 2 1 2 Latching flag F
4. INSTALLATION INSTRUCTIONS Large Flat Panel Static Mount S CHIEF PST16 Our Mounts Your PST16 Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved A IMPORTANT WARNINGS AND CAUTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions DIMENSIONS WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty Itis t
5. Move two latching flags on PST16 to the CLOSED position See Figure 6 Installation Instructions PST16 Latching flag Figure 6 7 OPTIONAL Lock the latching flags with a padlock or bolt if required See Figure 7 Place lock or bolt here to lock latching flag Figure 7 8 Route wires and cables to display PST16 Installation Instructions CHIEF Our Mounts Your Vision Chief Manufacturing a products division of Milestone AV Technologies 8805 002006 Rev02 2010 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 08 10 USA International Europe Asia Pacific p TI U gt 0 8401 Eagle Creek Parkway Savage MN 55378 800 582 6480 952 894 6280 877 894 6918 952 894 6918 Fellenoord 130 5611 ZB EINDHOVEN The Netherlands 31 0 40 2668620 31 0 40 2668615 Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477 s d D
6. he installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located on the PST16 does not exceed 200 Ibs 90 7 kg Use with products heavier than the maximum weight indicated may result in collapse of the mount and its accessories causing possible injury MEASUREMENTS MILLIMETERS INCHES Installation Instructions PST16 LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Pencil Mark Marcar con l piz Stiftmarkierung Marcar com l
7. igure 4 3 Align mounting buttons on display with teardrop mounting holes in mount See Figure 5 4 Move display forward until recessed area of mounting buttons is positioned over lower area of teardrop mounting holes See Figure 5 Ex 4 5 Lower display until recessed area of mounting buttons is seated in lower area of teardrop mounting holes See Figure 5 Figure 3 Display Installation WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT DO NOT install display in a manner other than that specified by the manufacturer Certain displays may require the use of an interface bracket for proper installation of the display If an interface bracket is not installed or there are any questions regarding which interface bracket should be used immediately contact a Chief Customer Service representative WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT Make sure mounting buttons Displ on display are properly seated in mounting holes in faceplate isp ay 1 Install Listed interface bracket not included following the installation instructions provided with the interface bracket 2 Move two latching flags on PST16 to the OPEN position e See Figure 4 Figure 5 6