1. wO O nr D tecteur inverseur de s curit D tecteur inverseur de s curit 25 FONCTIONNEMENT IMPORTANTES CONSIGNES DE SECURITE AVERTISSEMENT cour r duire le risque de BLESSURES GRAVES ou DE MORT LIRE ET SUIVRE TOUS LES AVERTISSEMENTS ET INSTRUCTIONS TOUJOURS garder les t l commandes hors de la port e des enfants Ne JAMAIS laisser les enfants faire fonctionner les t l commandes ou les boutons poussoirs de la commande de porte ou jouer avec ceux ci Actionner la porte de garage UNIQUEMENT lorsqu on peut la voir clairement qu elle est bien r gl e et qu il n y a aucun obstacle la course de la porte TOUJOURS garder la porte de garage en vue jusqu sa fermeture compl te PERSONNE NE DOIT TRAVERSER LE PARCOURS DE LA PORTE EN MOUVEMENT PERSONNE NE DOIT PASSER SOUS UNE PORTE ARR T E EN COURS D OUVERTURE Si possible utiliser la poign e de d clenchement d urgence pour d gager le chariot UNIQUEMENT lorsque la porte de garage est FERMEE Des ressorts faibles ou bris s ou une porte d s quilibr e peuvent causer la chute rapide et ou impr vue d une porte ouverte Ne JAMAIS utiliser la poign e de d clenchement d urgence moins que l entr e de garage ne soit d gag e absence de personnes et d obstacles Utilisation de votre ouvre porte de garage Votre t l
2. Des fonctions d autodiagnostic ont t programm es dans votre ouvre porte de garage Le bouton learn ou le voyant LED de diagnostic mettra un certain nombre d clairs avant de faire une pause pour indiquer la d couverte d un probl me potentiel Consulter la fiche diagnostique ci dessous ou LED diagnostic Bouton Fiche Diagnostique ETC DES Oo Sympt me Un des t moins lumineux des d tecteurs de s curit ou les deux n met pas une lumi re constante Cassure du fil des d tecteurs de s curit e Inspecter les fils du d tecteur pour d tecter un court circuit agrafe dans le fil corriger coup ou d connect la polarit des branchements fils noir blanc invers s les fils cass s ou d branch s remplacer relier si n cessaire OU D connecter tous les fils de la plaque arri re du moteur 2ECLAIRS Retirer les d tecteurs de leurs supports et raccourcir les fils des d tecteurs une longueur de 1 2 pieds 30 60 cm partir de l arri re de chaque d tecteur Court circuit du fil des Rattacher la cellule de transmission au moteur l aide des fils raccourcis Si le t moin d tecteurs de s curit ou lumineux de la cellule de transmission brille de mani re constante fixer la cellule de inversion des fils r ception noir blanc Aligner les d tecteurs
3. Diffuseur Ins rer d abord les languettes inf rieur es du diffuseur Fentes inf rieures de chasis AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite de la chute d une porte de garage e Si possible utiliser la poign e de d clenchement d urgence pour d gager le chariot UNIQUEMENT lorsque la porte de garage est FERMEE Des ressorts faibles ou bris s ou une porte d s quilibr e peuvent causer la chute rapide et ou impr vue d une porte ouverte e Ne JAMAIS utiliser la poign e de d clenchement d urgence moins que l entr e de garage ne soit d gag e absence de personnes et d obstacle e Ne JAMAIS utiliser la poign e pour ouvrir ou fermer la porte Il y a risque de chute si le n ud de la corde se d fait Levier de d clenchement du chariot Poign e de d clenchement d urgence 17 POSE 10 OPERATION Exigences lectriques Pour viter les difficult s pendant la pose ne pas faire fonctionner l ouvre porte pour le moment Afin de minimiser les risques de chocs lectriques le cordon d alimentation de l ouvre porte de garage comporte une fiche trois broches dont une de mise la terre Cette fiche ne peut tre branch e que dans une prise de courant mise la terre Si la fiche ne peut pas tre branch e dans la prise de courant qui existe s adresser un lectricien qualifi pour faire pos
4. CHAMBERLAIN The Chamberlain Group Inc 845 Larch Avenue Elmhurst Illinois 60126 1196 Al as er www liftmaster com PROFESSIONAL SECURITY GARAGE DOOR OPENER Models 3110C 1 3 HP 3220C 1 2 HP For Residential Use Only Owner s Manual m Please read this manual and the enclosed safety materials carefully m Fasten the manual near the garage door after installation m The door WILL NOT CLOSE unless the Protector System is connected and properly aligned m Periodic checks of the opener are required to ensure safe operation m The model number label is located on the front panel of your opener TABLE OF CONTENTS Introduction 2 5 Safety symbol and signal word review 2 Preparing your garage door 3 Tools needed 3 PIANINO PRE ER 4 Carton inventory cccecceeceeeeeeeeeeesneeeseaeeeseaeeeteaeeeseaees 5 Hardware inventory cceecscceeeeesneeeeeeeenneeeeeeeneeeeeees 5 Assembly 6 7 Fasten rail to the motor unit 6 Install the trolley 6 Attach the rail brackets 7 Installation 7 22 Installation safety instructions 7 Determine the header bracket location 8 Install the header bracket 9 Attach the rail to the header bracket 10 Install the Protector System 11 13 Position the Opener 0 eeeeeeeeeeeeneeeeeeenteeeete
5. Self Threading Screw 1 4 14x5 8 Top of Door Inside of Door Optional Placement METAL DOOR Nut Top of Door Inside Top Edge of Door Optional Placement Carriage Bolt 5 16 x2 Not Provided WOOD DOOR lag screws 5 16 x1 1 2 Not Provided INSTALLATION STEP 13 Connect Door Arm to Trolley Inner Outer Trolley Trolley Follow instructions which apply to your door type as illustrated below and on the following page SECTIONAL DOORS ONLY e Make sure garage door is fully closed Pull the emergency release handle to disconnect the outer trolley from the inner trolley Slide the outer trolley back away from the door about 2 5 cm as shown in Figures 1 2 and 3 Clevis Pin 5 16 x1 Fastener Straight Door Arm Door Bracket ES Emergency V Release Handle CO00OHND 00000 Figure 1 Fasten straight door arm section to outer trolley with the 5 16 x1 clevis pin Secure the Curved Dror Ann connection with a ring fastener a xd Fasten curved section to the door bracket in the same way using the 5 16 x1 1 4 clevis pin Figure 1 e Figure 2 Bring arm sections together Find two pairs of holes that line up and join sections Select holes as far apart as possible to increase door arm rigidity oh ts Figure 3 Hole alignment alternative j If holes in curved arm are above holes in straight se
6. ce que la porte remonte normalement Apr s chaque r glage faire faire un cycle complet l ouvre porte e Si la porte remonte durant le cycle de fermeture et que les lumi res de l ouvre porte ne clignotent pas AUGMENTER LA FORCE DE FERMETURE DOWN en tournant la vis de r glage dans le sens horaire Effectuer de petits r glages jusqu ce que la porte fasse un cycle de fermeture complet Apr s chaque r glage faire faire un cycle complet l ouvre porte Ne pas augmenter la force au del du niveau n cessaire pour fermer la porte 2 V rification de la force d ouverture UP e Pendant que la porte est environ mi chemin de sa course d ouverture essayer de l arr ter la main La porte doit s arr ter S il est difficile de retenir la porte ou si la porte ne s arr te pas DIMINUER LA FORCE D OUVERTURE UP en tournant la vis de r glage dans le sens antihoraire Effectuer de petits r glages jusqu ce que la porte s arr te facilement et s ouvre enti rement Apr s chaque r glage faire faire un cycle complet l ouvre porte e Si la porte ne s ouvre pas d au moins 5 pieds 1 5 m AUGMENTER LA FORCE D OUVERTURE UP en tournant la vis de r glage dans le sens horaire Effectuer de petits r glages jusqu ce que la porte s ouvre compl tement Au besoin r gler de nouveau la course d ouverture UP Apr s chaque r glage faire faire un cycle complet l ouvre porte AVERTISSEMENT Sans un sys
7. applique a votre installation Des mat riaux suppl mentaires peuvent tre n cessaires Il vous sera peut tre utile de vous reporter a cette page et aux illustrations qui l accompagnent en proc dant la pose de l ouvre porte POSE DE PORTE ARTICULEE PLAFOND FINI Une corni re et des fixations peuvent tre ll faudra poser des renforts horizontaux requises Se reporter et verticaux dans le cas d une porte de la page 15 garage l g re en fibre de verre en acier en aluminium en panneaux de verre etc Se reporter la page 19 pour plus de d tails Ressort OU de torsion lt ce Le Ws V Commande a Linteau e _ T Ressort de traction ee l A of cont de porte Porte murale d acc s Ligne du centre S vertical de la porte de garaj yp D VY eh D tecteur inverseur de s curit L espace entre le plancher et le D tecteur inverseur de s curit PAS de la porte ne doit pas tre sup rieur a 1 4 po 6 mm POSE DE PORTE RIGIDE SANS GUIDES PLAFOND FINI TS gt Une corni re et des IST fixations peuvent tre requises Se reporter la page 15 TT Linteau Moteur le Rail PORTE RIGIDE AVEC GUIDES i de po
8. ventuelles BLESSURES GRAVES ou LA MORT e TOUJOURS appeler un technicien form en syst mes de porte si la porte de garage force ou est d s quilibr e Une porte de garage d s quilibr e peut ne pas remonter au besoin e Ne JAMAIS tenter de desserrer d placer ou r gler la porte de garage ainsi que les ressorts c bles poulies supports de porte ou leurs ferrures de montage lesquels sont tous sous une tension EXTR ME e D sactiver TOUTES les serrures et retirer TOUTES les cordes raccord es la porte de garage AVANT de poser et d utiliser l ouvre porte de garage afin d viter un emm lement ATTENTION Pour pr venir les dommages la porte de garage et l ouvre porte e TOUJOURS d sactiver les serrures avant de poser et d utiliser l ouvre porte e Faire fonctionner l ouvre porte de garage UNIQUEMENT une tension de 120 V 60 Hz pour viter les d fauts de fonctionnement et les dommages Outils n cessaires Lors de l assemblage de la pose et du r glage de louvre porte les instructions feront appel aux outils main illustr s ci apr s YY Scie a m taux Pince coupante Forets de 3 16 de po eee ao Marteau de 5 16 de po et 5 32 de po Escabeau Pince universelle Tournevis E bD Cl molette Planification Identifier le type et la hauteur de votre porte de garage Examiner la r gion du garage pour noter si l une des conditions ci apr s s
9. Figure 2 PR C BL E Bo te simple Pour remettre le couvercle en place ins rer les languettes Pour remettre le couvercle en Fil de sonnerie inf rieures en premier place ins rer les languettes conducteurs inf rieures en premier 24V Figure 3 Figure 4 Bornes filet es Commande de porte clair e Panneau commande de porte Connexions de commande A de porte Pour rel cher le fil enfoncer la languette l aide de l extr mit du tournevis Rouge Blanc Gris E706 po 11 mm gt gt D nuder le fil sur 7 16 po 11 mm POSE 8 OPERATION Pose des ampoules e Visser une ampoule de 100 watts maximum dans chaque douille La lumi re s allumera et restera allum e pendant environ 4 1 2 minutes aussit6t que le courant sera tabli La lumi re s teindra ensuite e Ins rer les languettes inf rieures du diffuseur dans les fentes du ch ssis Basculer vers le ch ssis afin d introduire les languettes sup rieures puis d poser lentement en place e Pour enlever abaisser les languettes sup rieures du diffuseur Faire pivoter le diffuseur d licatement vers l arri re et le bas puis tirer pour lib rer les ampoules Proc der soigneusement afin d viter de briser les languettes inf rieures du diffuseur e Inverser la proc dure pour fermer le diffuseur e Si l ampoule br le pr matur ment en raison de la vibration remplacer la par une ampoule d o
10. R glage des courses 23 R glage de la force 24 Contr le du syst me d inversion de s curit 25 Essai du Syst me Protector 25 Fonctionnement 26 30 Instructions de fonctionnement en toute s curit 26 Utilisation de votre ouvre porte de garage 26 Utilisation de la commande de porte murale 27 Ouverture manuelle de la porte 27 Entretien de votre ouvre porte de garage 28 D fauts de fonctionnement 29 Fiche diagnostique 30 Programmation 31 32 Pour ajouter ou reprogrammer une t l commande main 31 Pour effacer tous les codes 31 T l commandes trois boutons 31 Pour ajouter reprogrammer ou modifier un NIP d entr e sans cl 32 Pi ces de r paration 33 34 Pi ces d assemblage du rail 33 Pi ces pour la pose 33 Pi ces d assemblage du moteur 34 Accessoires 35 Pi ces de r paration et service 36 Garantie 36 Cet ouvre porte de garage a t con u et test dans le but d offrir un service s r condition qu il soit install utilis entretenu et test en stricte conformit avec les instructions et les avertissements contenus dans le pr sent
11. Surchauffe du moteur ou Course courte de 6 8 po 15 20 cm ventuelle panne du capteur e D brancher le moteur pour le r armer Essayer de mettre le moteur en marche v rifier de r gime D brancher pour le code de diagnostic le r armer e S il met encore 5 clairs et que le moteur se d place de 6 8 po 15 20 cm remplacer le capteur de r gime e Si le moteur ne fonctionne pas le moteur a surchauff Attendre 30 minutes et essayer nouveau Si le moteur ne se met toujours pas en marche remplacer la carte logique 6 ECLAIRS D Sympt me Le moteur ne fonctionne pas Panne du circuit moteur Remplacer la carte logique car les pannes de moteur sont rares Remplacer la carte logique du r cepteur PROGRAMMATION REMARQUE Si cet ouvre porte de garage Security est utilis avec une t l commande mettrice a code fixe le dispositif technique que contient le r cepteur de l ouvre porte et qui procure une protection contre les vols de code se trouvera contourn Le d tenteur des droits d auteur de cet ouvre porte de garage n autorise pas l acheteur ni le fournisseur de la t l commande mettrice code fixe contourner ce dispositif technique Louvre porte de garage a t programm en usine de mani re fonctionner avec la t l commande a main fournie La porte s ouvrira et se fermera lorsqu on appuiera sur le gros bouton poussoir Ci apr s se trouvent des instructions pour programmer
12. arm disconnect straight arm Cut about 6 516 9 15 cm from the solid end Reconnect to trolley Ee 9 with cut end down as shown dy Bring arm sections together Find two pairs of holes that line up and join with 7 bolts lock washers and nuts 5 P OITS e Pull the emergency release handle toward the 5 16 18x7 8 Door Bracket opener at a 45 angle so that the trolley release arm is horizontal Proceed to Adjustment Step 1 page 23 Trolley will re engage automatically when Figure 2 opener is operated HARDWARE SHOWN ACTUAL SIZE Nut 5 16 18 Lock Washer 5 16 Ring Fastener 5 16 18 Clevis Pin Clevis Pin Hex Bolt 5 16 x1 Trolley 5 16 x1 1 4 Door Bracket 5 16 18x7 8 Bolts 5 16 18x7 8 Cut this end Figure 3 21 ALL ONE PIECE DOORS 1 Assemble the door arm Figure 4 e Fasten the straight and curved door arm sections together to the longest possible length with a 2 or 3 hole overlap e With the door closed connect the straight door arm section to the door bracket with the 5 16 x1 1 4 clevis pin e Secure with a ring fastener 2 Adjustment procedures Figure 5 On one piece doors before connecting the door arm to the trolley the travel limits must be adjusted Limit adjustment screws are located on the left side panel as shown on page 23 Follow adjustment procedures below e Open door adjustment decrease UP travel limit Turn the UP limit adjustment
13. commande main et ouvre porte Security ont t r gl s en usine un code compatible qui change avec chaque usage acc dant de mani re al atoire plus de 100 milliards de nouveaux codes Votre ouvre porte fonctionnera avec un nombre allant jusqu huit t l commandes Security et un Syst me d entr e sans cl Si vous achetez une nouvelle t l commande ou que vous d sirez d sactiver toute t l commande suivez les instructions de la section Programmation Actionner l ouvre porte suivant l une des m thodes ci apr s e La t l commande main Appuyer sur le bouton poussoir jusqu ce que la porte commence se d placer e La commande de porte murale Tenir la barre ou le bouton poussoir enfonc jusqu ce que la porte commence se d placer e Le syst me d entr e sans cl Se reporter la section Accessoires s il est fourni avec votre ouvre porte de garage il doit tre programm avant usage Se reporter la section Programmation Lorsque l on actionne l ouvre porte de garage et que les d tecteurs inverseurs de s curit sont correctement install s et align s 1 Si la porte est ouverte elle se fermera Si elle est ferm e elle s ouvrira 2 Si la porte est en course de fermeture elle remontera 3 Si la porte est en course d ouverture elle s arr tera 4 Si on l a arr t e en position partiellement ouverte elle se fermera 10 11 26 8 Ne
14. gt re adjustments particularly during the first year of operation Pages 23 and 24 refer to the limit and force adjustments Only a screwdriver is required Follow the t instructions carefully A Q eat a 6 FORCE CONTROLS 3 Repeat the safety reverse test Adjustment Step 3 page 25 after alte LIMIT CONTROLS any adjustment of limits or force THE REMOTE CONTROL BATTERY The lithium battery should produce power for up to 5 years To replace battery use the visor clip or screwdriver blade to pry open the case as shown Insert battery positive side up Dispose of old battery properly Battery H f positive So side up 28 MAINTENANCE SCHEDULE Once a Month e Manually operate door If it is unbalanced or binding call a trained door systems technician e Check to be sure door opens amp closes fully Adjust limits and or force if necessary See pages 23 and 24 e Repeat the safety reverse test Make any necessary adjustments See Adjustment Step 3 Once a Year e Oil door rollers bearings and hinges The opener does not require additional lubrication Do not grease the door tracks WARNING To prevent possible SERIOUS INJURY or DEATH e NEVER allow small children near batteries e f battery is swallowed immediately notify doctor NOTICE To comply with FCC and or Industry Canada IC rules adjustment or modifications of this receive
15. hardware all of which are under EXTREME tension MUST be made by a trained door systems technician ALWAYS disconnect electric power to garage door opener BEFORE making any repairs or removing covers SAVE THESE INSTRUCTIONS 6 If obstructed while opening the door will stop 7 If fully open the door will not close when the beam is broken The sensor has no effect in the opening cycle If the sensor is not installed or is misaligned the door won t close from a hand held remote However you can close the door with the Door Control the Outside Keylock or Keyless Entry if you activate them until down travel is complete If you release them too soon the door will reverse The opener lights will turn on under the following conditions when the opener is initially plugged in when power is restored after interruption when the opener is activated They will turn off automatically after 4 1 2 minutes or provide constant light when the Light feature on the Multi Function Door Control is activated Bulb size is 100 watts maximum Security light feature Lights will also turn on when someone walks through the open garage door With a Multi Function Door Control this feature may be turned off as follows With the opener lights off press and hold the light button for 10 seconds until the light goes on then off again To restore this feature start with the opener lights on then press and hold the light button for
16. l commande ENTRETIEN DE L OUVRE PORTE DE GARAGE R GLAGES DE COURSE ET DE FORCE Les conditions climatiques risquent de causer de petites modifications dans le fonctionnement de la porte qui devra alors tre r gl e en particulier apr s la premi re ann e d utilisation Se reporter aux pages 24 et 25 pour les r glages des courses d ouverture et de fermeture et de la force Seul un tournevis est requis Suivre attentivement les instructions Oem D gt we O COMMANDES DE FORCE Proc der toujours au contr le de inversion de s curit se reporter la 3e op ration page 26 des r glages S apr s avoir proc d un r glage des ee DE courses ou de la force LA PILE DE LA TELECOMMANDE La pile au lithium devrait durer pendant une p riode allant Pile au p le jusqu 5 ans Pour changer la positif vers pile ouvrir le bo tier comme Je haut illustr en le soulevant l aide de la pince du pare soleil ou de la lame d un tournevis Ins rer la pile avec le c t positif vers le haut Se d barrasser de la pile usag e convenablement 28 P RIODICIT S D ENTRETIEN Une fois par mois e Faire fonctionner la porte la main Si elle est d s quilibr e ou si elle force appeler un technicien form en syst mes de porte e S assurer que la porte s ouvre et se ferme compl tement Au besoin r gler les commandes de course et
17. t Centerline of Garage Door of Garage Door Self Threading Screw 1 4 14x5 8 Figure 4 Figure 3 ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also e Center the door bracket on the top of the door in line with the header bracket as shown Mark either the left and right or the top and bottom holes e Metal Doors Drill 3 16 pilot holes and fasten the bracket with the 1 4 14x5 8 self threading screws provided Wood Doors Drill 5 16 holes and use 5 16 x2 carriage bolts lock washers and nuts not provided or 5 16 x1 1 2 lag screws not provided depending on your installation needs NOTE The door bracket may be installed on the top edge of the door if required for your installation Refer to the dotted line optional placement drawing Header Wall Bracket Optional Placement of Door Bracket Vertical Centerline of 2x4 Support Garage Door Finished Ceiling HORIZONTAL AND VERTICAL REINFORCEMENT IS NEEDED 4 FOR LIGHTWEIGHT GARAGE f DOORS FIBERGLASS if ALUMINUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED or for the optional installation use to fasten door bracket 20 For a door with no exposed framing HARDWARE SHOWN ACTUAL SIZE Self Threading Screw 1 4 14x5 8
18. 10 seconds until the light goes off then on again Using the Wall Mounted Door Control Press the push button to open or close the door Press again to reverse the door during the closing cycle or to stop the door while it s opening THE MULTI FUNCTION DOOR CONTROL Press the push bar to open or close the door Press again to reverse the door during the closing cycle or to stop the door while it s opening Light feature Press the Light button to turn the opener light on or off It will not control the opener lights when the door is in motion If you turn it on and then activate the opener the light will remain on for 4 1 2 minutes Press again to turn it off sooner The 4 1 2 minute interval can be changed to 1 1 2 2 1 2 or 3 1 2 minutes as follows Press and hold the Lock button until the light blinks about 10 seconds A single blink indicates that the timer is reset to 1 1 2 minutes Repeat the procedure and the light will blink twice resetting the timer to 2 1 2 minutes Repeat again for a 3 1 2 minute interval etc up to a maximum of four blinks and 4 1 2 minutes Lock feature Designed to prevent operation of the door from hand held remote controls However the door will open and close from the Door Control the Outside Keylock and the Keyless Entry Accessories To activate press and hold the Lock button for 2 seconds The push bar light will flash as long as the Lock feature is on To turn off press
19. 4 plat sur le plancher centr e sous la porte de garage e Fermer la porte La porte doit remonter d s qu elle touche l obstacle d inversion de s curit e Apr s avoir r gl une commande force ou course il peut tre n cessaire de r gler l autre commande e Apr s avoir effectu quelque r glage que ce soit on DOIT faire l essai du syst me d inversion de s curit La porte de R GLAGE garage DOIT remonter au contact d un objet d une hauteur de f A 1 1 2 po 3 8 cm ou un 2 x 4 pos plat sur le sol e Sila porte s arr te sur l obstacle sa course de fermeture n est pas suffisante Augmenter la course de fermeture DOWN en tournant la vis de r glage DOWN de 1 4 de tour dans le sens antihoraire REMARQUE Dans le cas d une porte articul e s assurer que les r glages ne forcent pas sur la biellette ni l ouverture ni la fermeture Se reporter aux illustrations de la page 21 e R p ter l essai e Lorsque la porte remonte sur la planche de 1 1 2 po 3 8 cm retirer l obstacle et faire faire 3 ou 4 cycles complets l ouvre porte afin de v rifier le r glage V RIFICATION DE S CURIT IMPORTANTE Faire l essai du syst me d inversion de s curit apr s e Chaque fois que l on modifie la longueur des biellettes et chaque fois que l on proc de un r glage de la force et de la course de l
20. 4 fix sur les poteaux oa oc Portede garage Point de course Ligne du centre le plus haut vertical de la de la porte du garage porte de garage eae Mer ae Plafond fini r i a 247 4 Support de Axe vertical de linteau la porte du garage l a Ressort de la porte Tire fond de 5 16 po 9 x 1 5 8 po Linteau Ligne du centre vertical de la porte de garage POSE 3 OPERATION Fixation du rail sur le support de linteau e Positionner l ouvre porte de garage sur le plancher juste sous le support de linteau Utiliser une des boites d emballage pour le prot ger REMARQUE Si le ressort de la porte g ne il faudra demander de l aide Demander une personne de bien retenir l ouvre porte sur un support temporaire de fa on que le rail ne touche pas le ressort e Positionner le support du rail contre le support de linteau e Aligner les trous des supports et les raccorder avec un axe de chape comme il est illustr e Introduire un anneau d arr t pour immobiliser Linteau Support de linteau Support de rail Anneau d arr t Support de linteau Axe de chape de _ 5 16 po x 2 3 4 po ne Support de rail temporaire GRANDEUR REELLE DES FIXATIONS Axe de chape de 5 16 po x 2 3 4 po Anneau d arr t 10 POSE 4 OPERATION Pose du Syst me Protector Les d tecteurs inverseurs de s curit doivent tre bien branch s
21. AU MUR e Centrer le support par rapport l axe vertical la partie inf rieure du support tant align e avec la ligne horizontale comme illustr la fl che du support doit tre orient e vers le plafond e Marquer la s rie verticale de trous de support Percer des avant trous de 3 16 de pouce et fixer fermement le support sur une solive avec les fixations fournies GRANDEUR R ELLE DES FIXATIONS pihhh Tire fond de 5 16 de po 9 x 1 5 8 de po POSE DU SUPPORT DE LINTEAU AU PLAFOND e Prolonger l axe vertical sur le plafond comme illustr e Centrer le support sur l axe vertical 6 pouces 15 cm au maximum du mur S assurer que la fl che est orient e dans le sens oppos au mur Le support peut tre encastr dans le plafond si le d gagement n est pas suffisant e Marquer les trous lat raux Percer des avant trous de 3 16 po et fixer fermement le support sur une solive du plafond l aide des fixations fournies Trous de fixation au plafond Le trou du clou n est pr vu que pour le positionnement seulement Des tire fond doivent tre utilis s pour fixer le support de linteau Trous de fixation au mur Le trou du clou n est pr vu que pour le positionnement seulement Des tire fond doivent tre utilis s pour fixer le support de linteau Trous de fixation au mur en option Axe vertical de la porte du garage Tire fond de 5 16 po 9 x 1 5 8 po 2 x
22. IMPROPER INSTALLATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE USE OF UNAUTHORIZED PARTS OR ACCESSORIES UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT LABOR CHARGES FOR DISMANTLING OR REINSTALLING A REPAIRED OR REPLACED UNIT REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON RESIDENTIAL USE THE USE OF UNAUTHORIZED PARTS OR ACCESSORIES WILL VOID THIS LIMITED WARRANTY If you have any questions as to whether accessories or replacement parts are authorized please contact Chamberlain THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH OR RELATING TO THE GARAGE DOOR OR GARAGE DOOR HARDWARE INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS DOOR ROLLERS DOOR ALIGNMENT AND HINGES ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT INA FEE TO YOU UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH THE USE OF OR INABILITY TO USE THIS PRODUCT IN NO EVENT SHALL SELLER S LIABILITY FOR BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT Some Provinces do not allow the exclusion or limitation of consequential incidental or special damages so the above limitation
23. JAMAIS utiliser la poign e pour ouvrir ou fermer la porte Il y a risque de chute si le n ud de la corde se d fait Apr s avoir r gl une commande force ou course il peut tre n cessaire de r gler l autre commande Apr s avoir effectu quelque r glage que ce soit on DOIT faire l essai du syst me d inversion de s curit On DOIT proc der une v rification mensuelle du syst me d inversion de s curit La porte de garage DOIT remonter au contact d un objet d une hauteur de 1 1 2 po 3 8 cm ou un 2 x 4 pos plat sur le sol TOUJOURS GARDER LA PORTE DE GARAGE BIEN QUILIBR E se reporter la page 3 Une porte mal quilibr e peut ne pas remonter au besoin et pourrait provoquer des BLESSURES GRAVES ou la MORT Toutes les r parations aux c bles ensembles de ressort et autres ferrures de montage qui sont tous sous une tension EXTR ME DOIVENT tre confi es un technicien form en syst mes de porte TOUJOURS mettre l ouvre porte de garage hors tension AVANT d effectuer quelque r paration que ce soit ou d enlever des couvercles CONSERVER CES INSTRUCTIONS 9 5 Si la fermeture de la porte est g n e la porte remontera Si obstacle interrompt le faisceau du d tecteur les lumi res de l ouvre porte clignoteront pendant 5 secondes 6 Si l ouverture de la porte est g n e la porte s arr tera 7 Si la porte est compl tement ouverte elle ne se fermera pas tan
24. PORTE METALLIQUE 7 Ligne du centre vertical de la porte de garaje EN ALUMINIUM EN ACIER EN PANNEAUX DE VERRE ETC NON FOURNIS a tr ET tts RER dae CE Pour une porte sans cadre expos ou pour l installation facu ative utiliser des tire fonds de 5 16 po x 1 1 2 po Non Fournis pour fixer 20 le support de la porte leds DES RENFORTS HORIZONTAUX ET f support de VERTICAUX SONT REQUIS DANS Y crou la porte LE CAS D UNE PORTE DE GARAGE _ 5 16 po 18 Rondelle frein LEGERE EN FIBRE DE VERRE de 5 16 po Dessus de la porte int rieur du garage Bord sup rieur de la porte Placement facultatif Boulon t te bomb e et a collet carr de 5 16 po x 2 po Non Fournis PORTE EN BOIS POSE 13 OPERATION Fixation de la biellette au chariot Suivre uniquement les instructions se reportant a votre type de porte comme illustr ci dessous et a la page suivante PORTE ARTICULEE SEULEMENT e S assurer que la porte du garage est compl tement ferm e Tirer la poign e de d clenchement d urgence pour d tacher le chariot ext rieur du chariot int rieur Reculer le chariot ext rieur en l loignant de la porte d environ 2 pouces 5 cm comme illustr aux figures 1 2et3 e Figure 1 Fixer la biellette droite sur le chariot ext rieur l aide d un axe de chape de 5 16 po x 1 po F
25. Parts and Service 36 Warranty 36 This garage door opener has been designed and tested to offer safe service provided it is installed operated maintained and tested in strict accordance with the instructions and warnings contained in this manual WARNING Mechanical WARNING Electrical CAUTION When you see these Safety Symbols and Signal Words on the following pages they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them The hazard may come from something mechanical or from electric shock Read the warnings carefully When you see this Signal Word on the following pages it will alert you to the possibility of damage to your garage door and or the garage door opener if you do not comply with the cautionary statements that accompany it Read them carefully Preparing your garage door Before you begin e Disable locks e Remove any ropes connected to garage door e Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift the door about halfway as shown Release the door If balanced it should stay in place supported entirely by its springs 2 Raise and lower the door to see if there is any binding or sticking If your door binds sticks or is out of balance call a trained door systems technician Sectional Doo
26. Support de moteur ACCESSOIRES 1702LMC D tachement rapide d ext rieur N cessaire pour un garage SANS porte d acc s Permet au propri taire d ouvrir la porte de garage manuellement partir de l ext rieur en d connectant le chariot Cl de verrouillage ext rieur Pour ouvrir automatiquement la porte du garage de l ext rieur sans la t l commande Rail complet de 8 pieds 2 4 m Pour permettre une porte de 8 pieds 2 4 m de s ouvrir compl tement 41A5281 A Q i Model 98LMC Supports de rallonge Facultatif Pour la pose du capteur de s curit au mur ou au sol Panneau de commande de porte avec d tection de mouvement Commande de porte multi fonction avec d tecteur de mouvement qui allume automatiquement l clairage de louvre porte pendant 5 minutes lorsqu il d tecte une personne p n trant dans le garage Le capteur peut facilement tre inhib si d sir Commande murale multifonction pour 2 et 3 portes Id al pour les domiciles qui comptent jusqu trois portes Trois postes de commande log s dans un m me panneau pour garder une apparence propre et d gag e Fonction de verrouillage qui emp che l actionnement de la porte l aide d une t l commande et commande d clairage O 376LMC Ouvre porte sans fil et sans cl avec Security Permet d ouvrir la porte de l ext rieur en entrant un code sur le clavier de conc
27. a solid surface such as the wall framing Extension brackets see accessories are available if needed If installing in masonry construction add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary The invisible light beam path must be unobstructed No part of the garage door or door tracks springs hinges rollers or other hardware may interrupt the beam while the door is closing Sensor Beam 6 15 cm max above floor Invisible Light Beam Protection Area Facing the door from inside the garage Sensor Beam 6 15 cm max above floor INSTALLING THE BRACKETS Be sure power to the opener is disconnected Install and align the brackets so the sensors will face each other across the garage door with the beam no higher than 6 15 cm above the floor They may be installed in one of three ways as follows Garage door track installation preferred e Slip the curved arms over the rounded edge of each door track with the curved arms facing the door Snap into place against the side of the track It should lie flush with the lip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figures 2 amp 3 e Place the bracket against the wall with curved arms facing the d
28. avoid installation difficulties do not run the garage door opener until instructed to do so To aid in assembly and installation replace the foam packing around the motor unit Remove it after Installation Step 4 e Working on a level surface align the rail assembly with the motor unit as shown Slip the coupling over the rail sprocket e Slide the rail through the motor unit bracket until the coupling fits securely over the motor unit sprocket Align the two bolt holes in the rail with those in the motor unit bracket Insert two 1 4 20x5 8 hex bolts and lock nuts Tighten securely with a 7 16 socket wrench Rail Assembly ASSEMBLY STEP 2 Install the Trolley e Slide the trolley onto and along the bottom of the rail until it snaps firmly in place Be certain to install it facing correctly the trolley release arm must be horizontal lock position with its arrow pointed away from the motor unit Sprocket Arrow must point toward garage door HARDWARE SHOWN ACTUAL SIZE Hex Bolt Lock Nut 1 4 20 x 5 8 1 4 20 Motor Unit Sprocket Motor Unit Bracket Lock Nuts Hex Bolts 1 4 20x5 8 Foam Packaging ASSEMBLY STEP 3 Attach the Rail Brackets e Align rail brackets to end of rail assembly as shown e Insert two 1 4 20 x 5 8 hex bolts and lock nuts Tighten securely with a 7 16 socket You have now finished assembling your garage door opener Please read the fo
29. before proceeding to Adjustment Step 2 Use a screwdriver to make limit adjustments Run the opener through a complete travel cycle after each adjustment NOTE Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off Simply wait 15 minutes and try again NOTE If anything interferes with the door s upward travel it will stop If anything interferes with the door s downward travel including binding or unbalanced doors it will reverse HOW AND WHEN TO ADJUST THE LIMITS If the door does not open completely but opens at least 5 feet 1 5 m Increase up travel Turn the UP limit adjustment screw clockwise One turn equals 2 5 cm of travel NOTE To prevent the trolley from hitting the cover protection bolt keep a minimum distance of 2 4 5 10 m between the trolley and the bolt If door does not open at least 5 feet 1 5 m Adjust the UP open force as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t close completely and the trolley bumps into the pulley bracket page 4 try lengthening the door arm page 21 and decreasing the down limit If the opener reverses in fully closed position Decrease down travel Turn the down limit adjustment screw clockwise One turn equals 2 5 cm of travel 23
30. button on the Multi Function Door Control 3 Continue holding both buttons while you press the push bar on the Multi Function Door Control all three buttons are held 4 Release buttons when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard 3 Button Remotes If provided with your garage door opener the large button is factory programmed to operate it Additional buttons on any Security 3 button remote or mini remote can be programmed to operate other Security garage door openers lt a To Add Reprogram or Change a Keyless Entry PIN NOTE Your new Keyless Entry must be programmed to operate your garage door opener USING THE LEARN BUTTON 1 Press and release the learn button on motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds enter a four digit personal identification number PIN of your choice on the keypad Then press and hold the ENTER button 3 Release the button when the y motor unit lights blink It has i learned the code If light bulbs are not installed two clicks will be heard To change an existing known PIN If the existing PIN is known it may be chang
31. c blage est bien fait entre les d tecteurs et l ouvre porte e Qu il n y a pas de fil bris 2 Si le t moin de la cellule mettrice est allum alors que le t moin de la cellule r ceptrice est teint V rifier l alignement V rifier s il y a un fil bris dans la cellule r ceptrice 3 Si le t moin de la cellule r ceptrice est faible aligner l un ou l autre des d tecteurs REMARQUE Lorsque le faisceau invisible est obstru ou mal align quand la porte se ferme cette derni re remontera Si la porte est d j ouverte elle ne se fermera pas La lumi re de l ouvre porte clignotera 10 fois si l ampoule n est pas pos e 10 clics se feront entendre Voir page 11 POSE 12 OPERATION Fixation du support de porte Suivre les instructions qui correspondent au type de porte comme il est illustr ci dessous ou a la page suivante Un renfort horizontal doit tre suffisamment long pour tre fix deux ou trois supports verticaux Un renfort vertical doit couvrir la hauteur du panneau sup rieur La figure 1 illustre un morceau de corni re utilis en tant que renfort horizontal Pour le renfort vertical 2 morceaux de corni re sont utilis s de fa on cr er un support en forme de U La meilleure solution consiste s adresser au fabricant de la porte de garage pour obtenir un n cessaire de renforts de porte afin de pouvoir poser l ouvre porte de garage REMARQUE Bon nombre de n ces
32. ce qu elle vise directement la cellule r ceptrice Serrer I crou e Desserrer l crou de la cellule r ceptrice et r gler le d tecteur jusqu ce qu il re oive le faisceau de la cellule mettrice Lorsque le t moin vert reste allum serrer l crou 18 AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite d lectrocution ou d un incendie e S assurer que ouvre porte est hors tension et couper le courant au circuit AVANT de retirer le couvercle pour proc der un branchement permanent La pose et le c blage de la porte de garage DOIVENT tre conformes tous les codes lectriques et de construction locaux Ne JAMAIS utiliser de cordon de rallonge ou d adaptateur bifilaire ni modifier la fiche de quelque mani re que ce soit pour l ins rer dans la prise S assurer que l ouvre porte est mis la terre BRANCHEMENT LECTRIQUE PERMANENT Patte de terre Vis verte de terre Fil de terre Fil blanc D PANNAGE DES D TECTEURS INVERSEURS DE S CURIT 1 Si lorsque la pose est termin e le t moin de la cellule mettrice ne reste pas constamment allum apr s l installation s assurer e Que le courant lectrique parvient bien l ouvre porte e Qu il n y a pas de court circuit dans les fils blanc ou blanc noir Ces court circuits peuvent se produire sous les agrafes ou la hauteur des branchements des bornes filet es e Le
33. de fermeture Un tour complet de la vis de r glage correspond 2 pouces 5 cm de course 3 Raccordement de la biellette sur le chariot e La porte tant ferm e raccorder la biellette courb e au trou de raccordement du chariot avec le dernier axe de chape Il sera peut tre n cessaire de soulever l g rement la porte pour proc der au raccordement e Faire tenir laxe de chape avec un anneau d arr t e Faire faire un cycle de fonctionnement complet l ouvre porte Si en position compl tement ouverte la porte est l g rement inclin e vers l arri re comme illustr diminuer la course de mont e UP jusqu ce que la porte soit parall le au sol REMARQUE En r glant la course d ouverture la page suivante la porte ne doit pas tre inclin e vers l arri re lorsqu elle est enti rement ouverte comme illustr ci dessous Une l g re inclinaison arri re causera une r sistance inutile ou un fonctionnement saccad ou les deux lorsque la porte est ouverte ou ferm e depuis la position enti rement ouverte de la biellette Biellette TS 00 0 0 002 Chariot int rieur Poign e de d clenchement d urgence Chariot compl tement Angle correct Trou de raccordement de la biellette Porte inclin e Biellette vers l arri re non d sirable Porte ouverte 22 REGLAGES 1 OPE
34. effacer tous les codes de la T l commandes a trois boutons m moire du moteur l A Programm en usine le gros bouton dont pourrait tre Pour d sactiver toute t l commande munie votre t l commande sert au fonctionnement de non d sir e effacer d abord tous les l ouvre porte de garage Les boutons suppl mentaires sur n importe quelle codes ee t l commande ou Enfoncer et tenir le bouton learn du t l commande miniature moteur jusqu ce que le t moin trois boutons Security lumineux learn s teigne environ 6 peuvent tre programm secondes Tous les codes pr c dents sont maintenant pour faire fonctionner effac s Reprogrammer chaque t l commande ou entr e d autres ouvre portes de sans cl qu on d sire utiliser garage Security Pour ajouter reprogrammer ou modifier un NIP d entr e sans cl REMARQUE Votre nouvelle entr e sans cl doit tre programm e de mani re faire fonctionner votre ouvre porte de garage UTILISATION DE LA COMMANDE DE PORTE MULTIFONCTION UTILISATION DU BOUTON LEARN 1 Enfoncer et tenir le bouton learn sur le moteur Le t moin lumineux learn s allumera en continu pendant 30 secondes 2 Dans un d lai de 30 secondes introduire un num ro d identification personnelle NIP quatre chiffres d
35. faire passer le fil le long du sommet du rail avec les fils du d tecteur inverseur de s curit Consulter la page 13 Ins rer tous les fils travers l ouverture sur le dessus du moteur et au dessus du bornier serre fils sur le panneau arri re Figure 4 Enlever 7 16 po 11 mm d isolation l extr mit du fil de sonnerie Raccorder le fil de sonnerie aux bornes raccordement rapide comme suit le fil blanc blanc et le fil blanc rouge rouge S parer les fils blanc et blanc noir suffisamment pour leur raccordement aux vis des bornes a raccordement rapide de l ouvre porte Torsader les fils de m me couleur Ins rer les fils dans les trous raccordement rapide blanc blanc et noir blanc gris Figure 4 REMARQUE Lors de la connexion de plusieurs commandes de porte l ouvre porte torsader les fils de m me couleur Ins rer les fils dans les trous raccordement rapide blanc blanc et rouge blanc rouge 6 Utiliser des punaises ou des agrafes pour fixer en permanence l tiquette d avertissement de prise au pi ge sur le mur pr s de la commande de porte et l tiquette d essai d inversion de s curit ouverture manuelle bien en vue l int rieur de la porte de garage REMARQUE Ne PAS brancher et faire fonctionner l ouvre porte pour le moment Le chariot se d placera jusqu la position compl tement ouverte mais ne reviendra pas la position ferm e avant que le fai
36. manuel AVERTISSEMENT M canique AVERTISSEMENT lectrique ATTENTION Lorsque vous verrez ces symboles de s curit et ces mots de signalement sur les pages suivantes ils vous aviseront de la possibilit de blessures graves ou de mort si vous ne vous conformez pas aux avertissements qui les accompagnent Le danger peut provenir de source m canique ou d un choc lectrique Lisez attentivement les avertissements Lorsque vous verrez ce mot de signalement sur les pages suivantes il vous avisera de la possibilit de dommages votre porte de garage ou ouvre porte de garage ou les deux si vous ne vous conformez pas aux nonc s de mise en garde qui l accompagnent Lisez les attentivement Pr paration de votre porte de garage Avant de commencer e D sactiver les serrures e Retirer toute corde raccord e la porte de garage e R aliser le test suivant pour s assurer que la porte de garage est quilibr e et qu elle ne force pas 1 Soulever la porte moiti comme illustr puis la rel cher Si elle est quilibr e elle devrait rester en place enti rement support e par ses ressorts 2 Faire monter et descendre la porte pour s assurer qu elle ne force pas Si votre porte force ou est d s quilibr e appeler un technicien form en syst mes de porte Porte articul e Porte rigide Pour pr venir d
37. ou de force Se reporter aux pages 24 et 25 e R p ter le contr le du dispositif d inversion de s curit Proc der tous les r glages n cessaires voir r glages 3 op ration Une fois par ann e e Huiler les rouleaux les roulements et les charni res de la porte Il n est pas n cessaire de lubrifier l ouvre porte de garage Ne pas graisser les guides de la porte AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT e Ne JAMAIS laisser de petits enfants proximit des piles e Aviser imm diatement un m decin en cas d ingestion d une pile AVIS Les r gles de la FCC ou d Industrie Canada IC ou les deux interdisent tout ajustement ou toute modification de ce r cepteur et ou de cet metteur sauf pour modifier le code ou pour remplacer la pile IL N EXISTE AUCUNE AUTRE PIECE SUSCEPTIBLE D ETRE ENTRETENUE PAR L UTILISATEUR V rifi pour conformit avec les normes de la FCC POUR UTILISATION LA MAISON OU AU BUREAU L utilisation est sujette aux deux conditions ci apr s 1 ce dispositif ne peut causer des interf rences nuisibles et 2 ce dispositif doit accepter toute interf rence re ue y compris une interf rence pouvant causer un fonctionnement non d sir DEFAUTS DE FONCTIONNEMENT 1 Ma porte ne se ferme pas et les ampoules de l clairage du moteur clignotent Le d tecteur inverseur de s curit doit tre raccord et align corre
38. preuve d achat avec tout produit renvoy pour r paration en vertu de la garantie Les produits renvoy s au vendeur pour r paration en vertu de la garantie qui d s leur r ception par le Vendeur sont confirm s comme tant d fectueux et couverts par cette garantie limit e seront r par s ou remplac s au choix exclusif du vendeur sans qu il ne vous en co te rien et ils seront renvoy s port pr pay Les pi ces d fectueuses seront r par es ou remplac es par des pi ces neuves ou des pi ces reconstruites en usine au choix exclusif du vendeur CETTE GARANTIE LIMIT E TIENT LIEU DE TOUTE AUTRE GARANTIE EXPLICITE OU IMPLICITE Y COMPRIS TOUTE GARANTIE IMPLICITE DE COMMERCIALISATION OU D APTITUDE A UN USAGE PARTICULIER OU AUTRE ET DE TOUTE AUTRE OBLIGATION OU RESPONSABILITE DE LA PART DU VENDEUR CETTE GARANTIE LIMITEE NE COUVRE PAS LES DOMMAGES AUTRES QUE LES DEFECTUOSITES LES DOMMAGES CAUSES PAR UNE INSTALLATION UNE UTILISATION OU DES SOINS INAPPROPRIES Y COMPRIS DE MANI RE NON LIMITATIVE L UTILISATION ABUSIVE L UTILISATION ERRON E L OMISSION D ASSURER UN ENTRETIEN RAISONNABLE ET N CESSAIRE L UTILISATION DE PIECES OU D ACCESSOIRES NON AUTORIS S OU TOUTE ALTERATION DE CE PRODUIT LES FRAIS DE MAIN D OEUVRE AFFERENTS AU DEMONTAGE OU LA R INSTALLATION D UNE UNITE REPAREE OU REMPLACEE LE REMPLACEMENT DES PILES ET DES AMPOULES ELECTRIQUES OU DES UNITES INSTALLEES A FINS NON RESIDENTIELLES Pour toute question concern
39. screw counter clockwise 4 turns Press the Door Control push button The trolley will travel to the fully open position Manually raise the door to the open position parallel to the floor and lift the door arm to the trolley The arm should touch the trolley just in back of the door arm connector hole Refer to the fully open trolley door arm positions in the illustration If the arm does not extend far enough adjust the limit further One full turn equals 2 5 cm of trolley travel e Closed door adjustment decrease DOWN travel limit Turn the DOWN limit adjustment screw clockwise 4 complete turns Figure 5 Fully Closed Inner Trolley Trolley Door Bracket Ring Fastener Clevis Pin Straight 5 16 x1 1 4 Arm Bolts 7 5 16 18x7 8 lt f Curved Door Arm Figure 4 Press the Door Control push button The trolley will travel to the fully closed position Manually close the door and lift the door arm to the trolley The arm should touch the trolley just ahead of the door arm connector hole Refer to the fully closed trolley door arm positions in the illustration If the arm is behind the connector hole adjust the limit further One full turn equals 2 5 cm of trolley travel 3 Connect the door arm to the trolley e Close the door and join the curved arm to the connector hole in the trolley with the remaining clevis pin It may be necessary to lift the door slightly to make th
40. si les t moins lumineux sont allum s remplacer les fils des d tecteurs Si les t moins lumineux de d tection ne s allument pas remplacer les d tecteurs de s curit Eo D ae Sympt me Le t moin LED n est pas allum sur la commande de porte ns Inspecter la commande de porte les fils pour d tecter un court circuit agrafe dans le Court circult de la fil remplacer si n cessaire commande de porte ou an du fil D connecter les fils au niveau de la commande de porte toucher les fils l un l autre Si le moteur se met en marche remplacer la commande de porte Si le moteur ne se met pas en marche d connecter les fils de la commande de porte du moteur Court circuiter momentan ment les terminaux rouge et blancs l aide d un c ble de raccord Si le moteur se met en marche remplacer les fils de la commande z de porte 4 ECLAIRS S Sympt me Le t moin lumineux metteur est allum en continu alors que le L ger m salignement des t moin lumineux r cepteur donne une lumi re faible ou clignote d tecteurs de s curit t moin e R aligner la cellule r ceptrice nettoyer le diffuseur et bien fixer les supports LED faible ou clignotant e V rifier que le guide de la porte est bien ancr au mur et ne bouge pas 5ECLAIRS CHR 2e Sympt me Le moteur a surchauff le moteur ne fonctionne pas ou le chariot est coinc sur le boulon d arr t le moteur ronfle bri vement capteur de r gime
41. votre ouvre porte en vue du fonctionnement avec d autres t l commandes Security Pour ajouter ou reprogrammer une t l commande main UTILISATION DU BOUTON LEARN UTILISATION DE LA COMMANDE DE PORTE MULTIFONCTION 1 Enfoncer et tenir le bouton de la t l commande qui fera fonctionner D votre porte de garage 1 Enfoncer et rel cher le bouton learn sur le moteur Le t moin lumineux learn s allumera en continu pendant 30 secondes 2 Tout en maintenant le bouton de la t l commande enfonc appuyer et 2 Dans un d lai de 30 secondes tenir le bouton LIGHT de la enfoncer et tenir le bouton de la AN commande murale de porte t l commande qui fera fonctionner Multifonction votre porte de garage 3 Maintenir les deux boutons enfonc s tout en appuyant sur le bouton poussoir de la commande pe CE mure e pore MUNoneton es h i trois boutons sont enfonc s appris le code Si les ampoules ne sont pas pos es deux clics x se feront entendre 4 Rel cher les boutons lorsque Se l clairage du moteur clignote Ila appris le code Si les ampoules ne sont pas pos es deux clics se feront entendre Pour
42. wire harness Receiver logic board assy Cover Model 3110C Model 3220C Drive coupling hub Light socket Light lens Chassis with rail bracket Motor support bracket 1702LMC 88SDC 41A5281 Model 98LMC 376LMC ACCESSORIES Outside Quick Release Required for a garage with NO access door Enables homeowner to open garage door manually from outside by disengaging trolley Outside Keylock Operates the garage door automatically from the outside when remote control is not handy 8 Foot 2 4 m Complete Rail To allow an 8 foot 2 4 m door to open fully Extension Brackets Optional For safety sensor installation onto the wall or floor L Motion Detecting Control Panel Multi function door control with motion sensor that automatically turns opener lights on for 5 minutes when it detects a person entering the garage Sensor can be easily deactivated when desired 2 amp 3 Door Multi Function Wall Control Ideal for homes with up to three garage doors Combine up to three controls into one wall control panel for a neat compact appearance Enhanced functions include Lock Feature to lock out outside radio signals while you are away from home and turn opener lights on or off from the control panel Wireless Keyless Entry with Security Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard Also can add a t
43. 1 il de r ception droite avec fil de sonnerie blanc et blanc noir Support du d tecteur deux conducteurs fix de s curit 2 UNIT DE RAIL Rondelle fendue de 5 16 po 4 Manchon de couplage 1 Vis 6AB x 1 1 4 po 2 Boulon hexagonal de 1 4 po 20 x 5 8 po 4 Vis 6 32 x 1 po 2 crou de 1 4 po 20 4 Vis autotaraudeuse 1 4 po 14 x 5 8 po 2 Agrafes isol es 30 Anneau d arr t 3 FIXATIONS DE POSE Boulon hexagonal de 5 16 po 18 x 7 8 po 4 Chevilles pour murs secs 2 Tire fond de 5 16 po 9 x 1 5 8 po 2 ae Boulon t te bomb e et collet carr Tire fond de 5 16 po 18 x 1 7 8 po 2 1 4 po 20 x 1 2 po 2 Axe de chape de 5 16 po x 2 3 4 po 1 crou oreilles de 1 4 po 20 2 Axe de chape de 5 16 po x 1 1 4 po 1 Corde Axe de chape de 5 16 po x 1 po 1 Poign e crou de 5 16 po 18 4 MONTAGE 1 OPERATION GRANDEUR REELLE DES FIXATIONS Fixation du rail sur le moteur Boulon a t te hexagonale Ecrou de de 1 4 po 20 x 5 8 po 1 4 po 20 Pour viter les difficult s pendant la pose ne faire fonctionner l ouvre porte de garage que lorsque cela est express ment indiqu Afin de faciliter le montage et l installation remettre l emba en mousse autour du moteur Le retirer apr s 4 du processus d installation e Sur une surface niveau aligner l assemblage du rail Pignon de avec le moteur tel qu indiqu moteur Support de e Glisser l accouple
44. 1 1 2 3 8 cm high object or 2x4 laid flat on floor Force Adjustment Controls Back Panel DOWN Force ADJUSTMENT STEP 3 Test the Safety Reversal System TEST e With the door fully open place a 1 1 2 3 8 cm board or a 2x4 laid flat on the floor centered under the garage door e Operate the door in the down direction The door must reverse on striking the obstruction ADJUST e If the door stops on the obstruction it is not traveling far enough in the down direction Increase the DOWN limit by turning the DOWN limit adjustment screw counterclockwise 1 4 turn NOTE On a sectional door make sure limit adjustments do not force the door arm beyond a straight up and down position See the illustration on page 21 e Repeat the test e When the door reverses on the 1 1 2 3 8 cm board remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment IMPORTANT SAFETY CHECK Test the Safety Reverse System after e Each adjustment of door arm length limits or force controls e Any repair to or adjustment of the garage door including springs and hardware e Any repair to or buckling of the garage floor e Any repair to or adjustment of the opener ADJUSTMENT STEP 4 Test the Protector System e Press the remote control push button to open the door e Place the opener carton in the path of the door e Press the remote control pu
45. CH T moin lumineux Support de d tecteur MONTAGE ET CABLAGE DES Figure 5 DETECTEURS INVERSEURS e Faire glisser un boulon a t te bomb e et collet carr de 1 4 po 20 x 1 2 po dans la fente de chaque d tecteur Utiliser des crous a oreilles pour fixer les d tecteurs aux supports avec les diffuseurs dirig s l un vers l autre de bee part et d autre de la porte S assurer que le diffuseur Boulon t te n est pas obstru par une rallonge de support Figure 5 bomb e et collet carr de 1 4 de po 20 x 1 2 de po e Serrer les crous oreilles la main Cheminement de fils recommand 1 En utilisant des agrafes isol es faire passer les fils de chacun des deux d tecteurs au rail au niveau du linteau de porte Figure 6 2 Croisez et torsader les deux fils l endroit o ils croisent Diffuseur GRANDEUR R ELLE DES FIXATIONS Pop le rail voir diagramme A Faire passer les fils dans les Boulon t te bomb e crou Agrafes isol es canaux situ s au sommet du rail le long de chacun des et collet carr de oreilles c t s vers le moteur Ne pas utiliser les canaux de chariot inf rieurs Utiliser la pointe d un tournevis pour bien rentrer les fils doucement dans les canaux REMARQUE Si votre porte d acc s est situ e pr s de la porte de garage il est possible d installer la commande de porte et de faire passer le fil de commande de porte le long du r
46. LLATION FINISHED CEILING Le Support bracket amp NT fastening hardware A i 7 is required Horizontal and vertical reinforcement q is needed for lightweight garage doors See page 15 Z fiberglass steel aluminum door with 0 glass panels etc See page 19 for details ail RSS Header Wall Motor unit Extension Spring ae OR Torsion Spring pes LE De a CRE Tred p i Wall mounted Access Door Door Control D y PE Vertical Centerline lof Garage Door sey o O Reversing Sensor Gap between floor and bottom of Safety door must not exceed 1 4 6 mm Reversing Sensor ONE PIECE DOOR WITHOUT TRACK SES Ce Support bracket amp fastening hardware is required See page 15 ail Wall mounted Door Control Access Door Access Door O a Safety Reversing oS P D Sensor Gap between floor and bottom of i eee Safety Safet door must not exceed 1 4 6 mm LEE Reversing Sensor aey Gap between floor and bottom of Reversing Sensor Safety door must not exceed 1 4 6 mm Reversing Sensor Carton Inventory Your garage door opener is packaged in two cartons purch
47. MC 1 button remote control 373LMC 3 button remote control 10A20 3V 2032 Lithium battery 1 required 29B137 Visor clip 41A5047 Door bracket w clevis pin amp fastener 178B34 Straight door arm section 41A4353 Header bracket w clevis pin amp fastener 41A5034 Safety sensor kit receiving and sending eyes with 3 2 conductor bell wire attached 41A5266 1 Safety sensor bracket 41B4494 1 2 Conductor bell wire white amp white red 178B35 Curved door arm section NOT SHOWN 41A4675 7 Installation hardware bag see page 3 114A3182 Owner s manual J O O1 R O ND k 8 8 8 8 8 6 8 68 8 s 6 33 Motor Unit Assembly Parts 31D477 41B4245 30B363 12A373 41A3150 41D4671 12D630 2 41A5388 144B41 144B42 20B17 158A69 410556 41A5394 81B170 1 DESCRIPTION Drive shaft cover Line cord Capacitor 1 2 HP Capacitor bracket Terminal block w screws Limit switch assembly Bracket light socket limit switch Motor drive assy complete with 22T Pulley 28T Pulley Drive belt Retainer rings Isolator bracket spacers Assy bracket motor mount Shaft limit worm 34 Brown Wire Center Limit Up Contact Down Contact LIMIT SWITCH ASSY Yellow Contact Wire 4104672 41A4837 1 4105417 4105416 41A5389 1D 41A5490 5 41A5490 6 41C22 1 175C147 108D78 41A5387 12B654 DESCRIPTION Screw drive RPM kit Worm gear and retainer Low voltage wire harness High voltage
48. Nut 5 16 18 Bolt 5 16 18x7 8 Lock Washer 5 16 Nut 5 16 18 Preferred range of bracket placement Figure 3 Top Mounting Tabs Utilizing existing installation INSTALLATION STEP 7 Install the Door Control Locate door control within sight of the door at a minimum height of 5 feet 1 5 m where small children cannot reach and away from moving parts of the door and door hardware The installation surface must be smooth and flat If installing into drywall Figure 1 drill 5 32 holes and use anchors provided For pre wired installations as in new home construction it may be mounted to a single gang box Figure 2 NOTE After installation a green indicator light behind the cover will indicate proper connection If not lit the Lock and Light features will not function reverse wires to correct 1 Strip 7 16 11 mm of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color white wire to 2 and white red wire to the 1 Figure 3 2 Lighted door control Fasten to wall with 6ABx1 1 2 self threading screws Multi function Remove white cover by gently prying at slot in top of the cover with a small flat head screwdriver Fasten with 6ABx1 1 4 self threading screws drywall installation or 6 32x1 machine screws into gang box as follows e Drill and install bottom screw allowing 1 8 3 mm to protrude above wall surface e Position bottom of door contr
49. PRE WIRED Figure 1 INSTALLATION Figure 2 INSTALLATION Single Geen Gang Box oer mmp ea o Replace Insert Bottom Tabs First To Replace 24 Volt Insert Bottom Tabs First Bell Wire Figure 3 Figure 4 Terminal Screws Wall Control Door Control Connections To release wire push in tab with screwdriver tip Red White Grey 746 11mm gt Strip wire 7 16 11 mm INSTALLATION STEP 8 Install the Lights e Install up to a 100 watt maximum light bulb in each socket The lights will turn ON and remain lit for approximately 4 1 2 minutes when power is connected Then the lights will turn OFF Insert bottom lens tabs into slots on chassis Tilt towards chassis to engage top tabs then drop down gently into place e To remove depress both top lens tabs Tilt lens slightly outward and down then pull out to clear bulbs Use care to avoid snapping off bottom lens tabs Reverse the procedure to close the lens If the bulbs burn out prematurely due to vibration replace with a Garage Door Opener bulb NOTE Use only standard light bulbs The use of short neck or speciality light bulbs may overheat the endpanel or light socket INSTALLATION STEP 9 Attach the Emergency Release Rope and Handle e Thread one end of the rope through the hole in the top of the red handle so NOTICE reads right side up as shown Secure with an overhand knot at least 1 2 5 cm from the end of the rope to preven
50. R REPAIR PARTS Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed accordingly WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION e PART NUMBER PART NAME MODEL NUMBER ADDRESS ORDERS TO THE CHAMBERLAIN GROUP INC Technical Support Group 6020 S Country Club Road www liftmaster com Tucson Arizona 85706 SERVICE INFORMATION TOLL FREE NUMBER 1 800 654 4736 For professional installation parts and service contact your local LIFTMASTER CHAMBERLAIN dealer Look for him in the Yellow Pages or call our Service number for a list of dealers in your area EEE EEE EEE EEE EEE EEE EEE EE EE EE EE EE EE EEE EEE EEE EE EE EE el fel ele EEE EEE EEE EE TEE LIFTMASTER GARAGE DOOR OPENER ONE YEAR LIMITED WARRANTY The Chamberlain Group Inc Seller warrants to the first retail purchaser of this product for the residence in which this product is originally installed that it will be free from any defect in materials and or workmanship for a period of one year from the date of purchase Additionally the motor is fully warranted for the lifetime of the product for Model 3220C The product must be used in complete accordance with Chamberlain s instructions for installation operation and care The proper operation of this product is dependent on your compliance with the Owner s Manual instructions regarding installation operation maintenance and test
51. RATION R glage des courses d ouverture et de fermeture Le r glage de ces courses fixe les points o la porte s arr tera lors de son ouverture ou de sa fermeture Pour faire fonctionner l ouvre porte appuyer sur le bouton poussoir de la commande de porte Faire faire un cycle complet l ouvre porte e La porte s ouvre t elle et se ferme t elle compl tement e Est ce que la porte reste ferm e sans remonter involontairement lorsqu elle est compl tement ferm e Si la r ponse est oui ces deux questions aucun r glage de la course n est requis moins que le test d inversion n choue se reporter la 3 op ration page 25 des r glages Les proc dures suivantes indiquent les r glages effectuer dans chaque cas Lire les proc dures attentivement avant de proc der la 2 op ration des r glages Utiliser un tournevis pour proc der aux r glages Faire faire un cycle complet l ouvre porte apr s chaque r glage REMARQUE Un fonctionnement r p t de l ouvre porte pendant le r glage risque de faire surchauffer le moteur et de provoquer son arr t Dans ce cas attendre environ 15 minutes avant de continuer REMARQUE Si quoi que ce soit g ne l ouverture de la porte elle s arr tera Si quoi que ce soit g ne la fermeture de la porte y compris des portes qui forcent ou qui sont d s quilibr es elle remontera COMMENT ET QUAND REGLER LES COURSES e Sila porte ne s ouvre pas compl temen
52. RES VENTE SERT L ENSEMBLE DE L AMERIQUE ET DU CANADA L INSTALLATION ET LES INFORMATIONS D ENTRETIEN SONT A LA PORT E DE VOTRE T L PHONE SEPT JOURS PAR SEMAINE APPELEZ COMMENT COMMANDER DES PI CES D TACH ES Les prix de vente seront fournis sur demande ou les pi ces seront exp di es des prix en vigueur et vous recevrez une facture cons quente LORSQUE VOUS COMMANDEZ DES PI CES DE RECHANGE DONNEZ TOUJOURS LES INFORMATIONS SUIVANTES SIMPLEMENT NOTRE NUM RO GRATUIT 1 800 654 4736 HEURES Heure standard centrale De 6 00 h 19 00 h du lundi au vendredi De 8 00 h 18 00 h le samedi 8 heures 16 heures de l apr s midi le dimanche e NUMERO DE PIECE NOM DE LA PIECE e NUMERO DE MOD LE ADRESSEZ LES COMMANDES THE CHAMBERLAIN GROUP INC Technical Support Group 6020 S Country Club Road Tucson Arizona 85706 NUM RO GRATUIT POUR LES INFORMATIONS D ENTRETIEN 1 800 654 4736 www liftmaster com Pour l installation professionnelle les pi ces d tach es et l entretien contactez votre revendeur local LIFTMASTER CHAMBERLAIN Cherchez le dans les pages jaunes ou appelez notre num o d entretien pour obtenir une liste des revendeurs dans votre r gion BE EEE EE EEE EEE EE EE EE AE EE EEE el ele fel EE EEE A EEE EEE EE EEE EE EE AE EE EE EEE EE EEE GARANTIE LIMIT E D UN AN SUR L OUVRE PORTE DE GARAGE LIFTMASTER Chamberlain Group Inc vendeur garantit au premier acheteur
53. S 2 OPERATION R glage de la force Les commandes de r glage de la force sont situ es sur le panneau arri re du moteur Elles servent a r gler la puissance du courant n cessaire a l ouverture et a la fermeture de la porte Si la force r gl e est trop faible la porte aura tendance a s arr ter l ouverture et a remonter a la fermeture Les variations saisonni res peuvent modifier le fonctionnement de la porte il faudra donc occasionnellement proc der un r glage Le r glage maximum de la force est de 3 4 de tour de vis Ne pas forcer la vis au del de cette limite Utiliser un tournevis pour r gler la force REMARQUE Si quoi que ce soit g ne l ouverture de la porte elle s arr tera Si quoi que ce soit g ne la fermeture de la porte y compris des portes qui forcent ou qui sont d s quilibr es elle remontera COMMENT ET QUAND REGLER LES FORCES 1 V rification de la force de fermeture DOWN e Pendant que la porte est environ mi chemin de sa course de fermeture essayer de l arr ter la main La porte doit remonter L inversion du mouvement de fermeture de la porte mi chemin ne garantit pas l inversion lorsqu il s agit d une obstacle de 1 1 2 po 3 8 cm Se reporter la 3 op ration des r glages page 25 S il est difficile de retenir la porte ou si la porte ne remonte pas DIMINUER LA FORCE DE FERMETURE DOWN en tournant la vis dans le sens antihoraire Effectuer de petits r glages jusqu
54. SIDE Attach with Concrete Anchors Not Provided Indicator Bracket MOUNTING AND WIRING THE SAFETY SENSORS Slide a 1 4 20x1 2 carriage bolt head into the slot on each sensor Use wing nuts to fasten sensors to brackets with lenses pointing toward each other across the door Be sure the lens is not obstructed by a bracket extension Figure 5 Finger tighten the wing nuts Recommended Wire Routing 1 Using insulated staples run the wires from both sensors to the rail at the door header Figure 6 2 Cross and twist the two wires where they meet the rail see inset A Run the wires inside the channels at the top of the rail along each side to the motor unit Do not use the lower trolley channels Use a screwdriver tip to tuck the wires snugly into the channels NOTE If your access door is near the garage door you may choose to install the door control at this time and run the door control wire along the rail with the sensor wires Use one rail channel for the door control wire and the other channel for both sensor wires If you choose this option follow instructions 1 3 on page 16 now Pull wires taut across the top of the chassis and insert into the opening above the terminal block see inset B You will complete the wiring in Installation Step 7 Figure 6 1 Run wires from sensors to end of rail at the door header Cross amp twist here to help contain wires in cha
55. Use tacks or staples to permanently attach entrapment warning label to wall near door control and manual release safety reverse test label in a prominent location on inside of garage door NOTE DO NOT connect the power and operate the opener at this time The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned See Step 11 on page 18 Lighted A Door Control Multi function To prevent possible SERIOUS INJURY or DEATH from electrocution e Be sure power is not connected BEFORE installing door control e Connect ONLY to 24 VOLT low voltage wires To prevent possible SERIOUS INJURY or DEATH from a closing garage door e Install door control within sight of garage door out of reach of children at a minimum height of 5 feet 1 5 m and away from all moving parts of door e NEVER permit children to operate or play with door control push buttons or remote control transmitters Activate door ONLY when it can be seen clearly is properly adjusted and there are no obstructions to door travel e ALWAYS keep garage door in sight until completely closed NEVER permit anyone to cross path of closing garage door HARDWARE SHOWN ACTUAL SIZE Lighted Door Control Button Insulated 6ABx1 1 2 Screw Staples SD SCO Multi function std installation Multi function pre wired Drywall 6AB x 1 1 4 Screw 6 32 x 1 Screw Anchors STANDARD i
56. WARNING Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system e If one control force or travel limits is adjusted the other control may also need adjustment e After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 3 8 cm high object or 2x4 laid flat on floor CAUTION To prevent damage to vehicles be sure fully open door provides adequate clearance l 00000000 Le Limit Adjustment Screws Left Side Panel t A Adjust UP Travel L A Adjust DOWN Travel If the door reverses when closing and there is no visible interference to travel cycle If the opener lights are flashing the Safety Reversing Sensors are either not installed misaligned or obstructed See Troubleshooting page 18 Test the door for binding Pull the emergency release handle Manually open and close the door If the door is binding or unbalanced call for a trained door systems technician If the door is balanced and not binding adjust the DOWN close force See Adjustment Step 2 ADJUSTMENT STEP 2 Adjust the Force Force adjustment controls are located on the back
57. a porte e Chaque fois que l on r pare ou que l on r gle la porte du garage y compris les ressorts et les fixations Chaque fois que l on r pare le plancher du garage Planche de 1 1 2 de po 3 8 cm ou 2 x 4 plat ou apr s un soul vement de celui ci e Chaque fois que l on proc de une r paration ou un r glage de l ouvre porte REGLAGES 4 OPERATION amp AVERTISSEMENT Essayer le Syst me Protection Sans un syst me d inversion de s curit bien install des eA le bouton ir de la t l d personnes plus particuli rement les petits enfants pourraient PE EE T al a a tre GRIEVEMENT BLESSEES ou TU ES par une porte de garage qui se referme pour ouvrir la porte e Mettre la bo te en carton de l ouvre porte dans la course de la porte e Appuyer sur le bouton poussoir de la t l commande pour fermer la porte La porte ne se d placera pas de plus d un pouce 2 5 cm et les lumi res de louvre porte clignoteront La porte de garage ne se fermera pas l aide d une t l commande si le t moin lumineux d un des deux d tecteurs est teint ce qui avertit que le d tecteur est mal align ou est obstru Si l ouvre porte ferme la porte lorsque le d tecteur inverseur de s curit est obstru et que les d tecteurs ne sont pas plus de 6 po 15 cm au dessus du sol appeler un technicien form en syst mes de porte
58. afety Reversing Sensor Safety Reversing Sensor OPERATION IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS ALWAYS keep remote controls out of reach of children NEVER permit children to operate or play with garage door control push buttons or remote controls ONLY activate garage door when it can be seen clearly it is properly adjusted and there are no obstructions to door travel ALWAYS keep garage door in sight until completely closed NO ONE SHOULD CROSS THE PATH OF THE MOVING DOCR NO ONE SHOULD GO UNDER A STOPPED PARTIALLY OPEN DOOR If possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly NEVER use emergency release handle unless garage doorway is clear of persons and obstructions Using Your Garage Door Opener Your Security opener and hand held remote control have been factory set to a matching code which changes with each use randomly accessing over 100 billion new codes Your opener will operate with up to eight Security remote controls and one Security Keyless Entry System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in the Programming section Activate your opener with any o
59. ail avec les fils de d tecteurs Utiliser un canal de rail pour le fil de commande murale et l autre canal pour les deux fils de d tecteurs Pour ex cuter cette option suivre les instructions 1 3 de la page 16 3 Tirez les fils fermement travers la partie sup rieure du chassis et ins rez dans l ouverture au dessus du borne voir diagramme B Ceci vous permettra de terminer la pose des fils de l tape 7 de l installation Figure 6 1 Faites passer les fils partir des d tecteurs vers l extr mite du rail au niveau de la t te de porte Croisez et pliez les fils cet endroit pour faciliter le placement des fils dans les canaux situ s au sommet du rail 2 Faites passer les fils le long des canaux vers le moteur Utilisez la lame d un tournevis pour les rentrer d licatement dans les canaux 3 Tirez les fils fermement travers la partie sup rieure du ch ssis et ins rez dans l ouverture au dessus de la borne serre fils 13 1 4 de po 20 x 1 2 de po 1 4 de po 20 A Linteau Fil de d tecteur Fil de d tecteur Support de linteau de rail Fil de sonnerie s gt Aire de protection du faisceau du lumi re invisible D tecteur inverseur POSE 5 OPERATION AVERTISSEMENT Positionnement de l ouvre porte Pour pr venir les dommages la porte de garage faire reposer le
60. aire tenir l axe de chape en place avec un anneau d arr t Fixer la biellette courb e au support de la porte de la m me mani re l aide d un axe de chape de 5 16 po x 1 1 4 po e Figure 2 Rapprocher les biellettes et aligner les trous Choisir les trous les plus loign s tant donn qu ils permettent aux biellettes d tre plus solides e Figure 3 M thode alternative Si les trous de la biellette courb e sont trop hauts d monter la biellette droite et couper 6 po 15 cm du bout Refixer la biellette droite sur le chariot en orientant la partie coup e vers le bas comme illustr Rapprocher les biellettes Aligner deux paires de trous et raccorder les deux biellettes avec les boulons les rondelles de blocage et les crous e Tirer la poign e de d clenchement d urgence vers le bas et l arri re vers l ouvre porte de garage un angle de 45 afin que la biellette de d gagement du chariot soit en position horizontale Passer la section r glages 1 op ration page 28 Le chariot se r enclenchera automatiquement lorsque l ouvre porte fonctionnera L Rondelle frein GRANDEUR R ELLE DES FIXATIONS crou de Boulon hexagonal de 5 16 po 18 5 16 po 18 x 7 8 de po de 5 16 po Axe de chape de 5 16 po x 1 po Chariot Axe de chape de 5 16 po x 1 1 4 po Anneau Support de la porte d arr t Chariot int rieur Chariot ext rieur Axe d
61. and hold the Lock button again for 2 seconds The push bar light will stop flashing The Push Button Lock Button Light Button Lock feature will also turn off whenever the Learn button on the motor unit panel is activated Additional features when used with the 3 Button hand held remote ZZ A To control the opener lights a Lp In addition to operating the door you may program the remote to operate the lights 1 With the door closed press and hold a small remote button that you want to control the light 2 Press and hold the Light button on the Multi Function door control 3 While holding the Light button press and hold the Lock button on the door control 4 After the opener lights flash release all buttons 27 B To operate one door using all three buttons on the hand held remote You may program the remote to open the door with the large button close it with the middle button and stop the door s movement with the third button NOTE If remote is already programmed you must first erase all codes See Programming 1 With the door closed press and hold the large remote push button 2 Press and hold the Lock button on the door control 8 Press and hold the door control push bar 4 After the opener lights flash release all buttons Open Close Stop WARNING To prevent possible SERIOUS INJURY or DEATH from a falling garage door e f possible use emergency rele
62. ant l autorisation des accessoires ou des pi ces de rechange veuillez contacter Chamberlain CETTE GARANTIE LIMITEE NE COUVRE AUCUN PROBLEME RELATIF A LA PORTE DE GARAGE OU AUX FERRURES DE MONTAGE DE LA PORTE DE GARAGE Y COMPRIS DE MANIERE NON LIMITATIVE LES RESSORTS DE LA PORTE LES ROULEAUX DE LA PORTE L ALIGNEMENT ET LES CHARNIERES DE LA PORTE DES FRAIS PEUVENT VOUS ETRE FACTURES SUITE A UNE INTERVENTION DE SERVICE S IL S AVERE QUE LE PROBL ME A EtE CAUSE PAR L UN DE CES ELEMENTS LE VENDEUR NE SERA EN AUCUNE CIRCONSTANCE RESPONSABLE DES DOMMAGES INDIRECTS ACCESSOIRES OU SPECIAUX DECOULANT DE L UTILISATION OU DE L INCAPACIT D UTILISER CE PRODUIT LA RESPONSABILITE DU VENDEUR AU TITRE DE LA RUPTURE DE GARANTIE DE LA RUPTURE DE CONTRAT DE LA NEGLIGENCE OU DE LA RESPONSABILITE INCONDITIONNELLE NE DEPASSERA EN AUCUN CAS LE COUT DU PRODUIT COUVERT PAR LES PR SENTES AUCUNE PERSONNE N EST AUTORISEE ASSUMER POUR NOUS UNE QUELQUE AUTRE RESPONSABILIT RELATIVEMENT LA VENTE DE CE PRODUIT Certaines provinces n autorisent pas l exclusion ou la limitation des dommages accessoires indirects ou sp ciaux il se peut donc que la limitation ou l exclusion susvis e ne s applique pas vous Cette garantie limit e vous donne des droits pr cis et vous pouvez galement avoir d autres droits qui varient d une province une autre GARANTIE LIMIT E DU MOTEUR Mod le 3220C Le moteur est enti rement garanti l acheteu
63. ase handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly e NEVER use emergency release handle unless garage doorway is clear of persons and obstructions e NEVER use handle to pull door open or closed If rope knot becomes untied you could fall To Open the Door Manually DISCONNECT TROLLEY The door should be fully o Ul joey closed if possible Pull down on the emergency release ah Trolley Release Arm handle so that the trolley release arm snaps into a vertical position and lift the door manually The lockout feature prevents the trolley from reconnecting automatically and the door can be raised and lowered manually as often as necessary TO RE CONNECT THE TROLLEY Pull the emergency release handle toward the opener at a in Manual Disconnect 1 Position amp LOCKOUT POSITION MANUAL DISCONNECT 45 degree angle so that the 3 gt dt trolley trolley release arm is Trolley horizontal The trolley will X Release reconnect on the next UP or ina a tea Handle Pull at 45 angle DOWN operation either manually or by using the door control or remote TORECONNE T CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS Weather conditions may cause some minor changes in door D operation requiring some
64. ased If anything is missing carefully check the which contain the motor unit and all parts illustrated packing material Parts may be stuck in the foam below Accessories will depend on the model Hardware for installation is also listed below Model 3220C Model 3110C Model 3220C 1 Model 3110C 1 E LE SECURITY SECURITY Remote Control __ 3 Button Remote Control 1 Button Remote Control Transmitter Visor Clip Multi Function Lighted Door Gontrol Panel Door Control Button Header Bracket 2 Conductor Bell Wire White amp White Red Curved Door P Arm Section A Sprocket Coupling Door Bracket o o o o o o Safety Labels and 2 Safety Reversing Sensors Literature Straight Door 1 Sending Eye and 1 Receiving Eye Arm Section With 2 Conductor White amp White Black Safety Sensor Bell Wire attached Bracket 2 RAIL ASSEMBLY Nut 5 16 18 4 Coupling Sleeve 1 Lock Washer 5 16 4 Hex Bolt 1 4 20 x 5 8 4 Screw 6ABx1 1 4 2 Nut 1 4 20 4 Screw 6 32x1 2 INSTALLATION HARDWARE Self Threading Screw 1 4 14x5 8 2 Hex Bolt 5 16 18x7 8 4 Insulated staples 30 Lag Screw 5 16 9x1 5 8 2 Ping Fastener 3 Lag Screw 5 16 18x1 7 8 2 Drywall Anchors 2 Clevis Pin 5 16 x2 3 4 1 Carriage Bolt 1 4 20x1 2 2 Clevis Pin 5 16 x1 1 4 1 Wing Nut 1 4 20 2 Clevis Pin 5 16 x1 1 Rope Handle ASSEMBLY STEP 1 Fasten the Rail to the Motor Unit To
65. ctement avant que l ouvre porte de garage n entame la proc dure de fermeture e V rifier que les d tecteurs inverseurs de s curit sont bien install s et d pourvus d obstruction Se reporter la 10 tape de pose Pose du Syst me Protector e V rifier le diagnostic du voyant LED concernant les clairs sur le moteur puis se reporter la fiche diagnostique la page suivante 2 Mes t l commandes ne font pas fonctionner la porte e V rifier que votre commande murale de luxe ne clignote pas Si elle clignote d sactiver le mode de verrouillage en suivant les instructions du passage consacr Utilisation de la commande de porte murale multifonction e Reprogrammer les t l commandes en suivant les instructions de programmation Se reporter au chapitre Programmation e Si la t l commande ne fait toujours pas fonctionner votre porte examiner le voyant LED de diagnostic et observer le cas ch ant les clairs sur le moteur puis se reporter la fiche diagnostique la page suivante 3 La porte inverse sa course sans raison apparente Apr s avoir proc d au r glage de la force ou des limites de course r p ter le contr le de l inversion de s curit Le besoin de proc der des r glages occasionnels des limites de courses et de la force est normal Les variations saisonni res en particulier peuvent alt rer la course de la porte e V rifier manuellement que la porte est bien qu
66. de d tail de ce produit pour la r sidence dans laquelle ce produit a t install l origine qu il sera exempt de vices de mat riaux et ou d ex cution pendant un d lai d un an depuis la date d achat En outre le moteur et la courroie sont garanti pendant la dur e du produit pour Mod le 3220C Le produit doit tre utilis en stricte conformit avec les instructions d installation d utilisation et d entretien donn es par Chamberlain Le fonctionnement appropri de ce produit d pend de votre observance des instructions du manuel concernant l installation l utilisation l entretien et les essais Cette garantie sera annul e au complet en cas de d faut de se conformer strictement ces instructions Veuillez noter que le syst me d inversion de s curit ne peut fonctionner ad quatement avec votre porte de garage s il n est pas ajust et test p riodiquement en conformit avec le manuel d instructions Si durant la p riode de garantie limit e il semble que ce produit comporte une d fectuosit couverte par cette garantie limit e APPELEZ NOTRE NUM RO GRATUIT DE SERVICE AU 1 800 654 4736 AVANT DE D MONTER CE PRODUIT Envoyez ensuite ce produit port pr pay et assur notre centre de service pour r paration en vertu de la garantie Lorsque vous appellerez au num ro gratuit de service on vous avisera des instructions d exp dition Veuillez inclure une br ve description du probl me et un re u dat faisant
67. de s curit et des mots de signalement 2 Pr paration de votre porte de garage 3 Outils n cessaires 3 Planification 4 Inventaire de la bo te d emballage 5 Inventaire des fixations 5 Montage 6 7 Fixation du rail au moteur 6 Installation du chariot 6 Montage des supports de rail 7 Pose 7 22 Instructions pour une pose en toute s curit 7 D terminer l emplacement du support de linteau 8 Pose du support de linteau 9 Fixation du rail sur le support de linteau 10 Pose du Syst me Protector 11 13 Positionnement de l ouvre porte 14 Accrochage de l ouvre porte 15 Pose de la commande de porte 16 Pose des ampoules 17 Pose de la corde et de la poign e de d clenchement d urgence 17 Exigences lectriques 18 Terminer l i du d tecteur inverseur de s curit 18 Fixation du support de la porte 19 20 Fixation de la biellette de la porte au chariot 21 22 INTRODUCTION Revue des symboles de s curit et des mots de signalement R glages 23 25
68. e door control Place manual release safety reverse test label in plain view on inside of garage door Upon completion of installation test safety reversal system Door MUST reverse on contact with a 1 1 2 3 8 cm high object or a 2x4 laid flat on the floor INSTALLATION STEP 1 Determine the Header Bracket Location WARNING To prevent possible SERIOUS INJURY or DEATH e Header bracket MUST be RIGIDLY fastened to structural Support on header wall or ceiling otherwise garage door might not reverse when required DO NOT install header bracket over drywall e Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry e NEVER try to loosen move or adjust garage door springs cables pulleys brackets or their hardware all of which are under EXTREME tension e ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door might not reverse when required Installation procedures vary according to garage door types Follow the instructions which apply to your door 1 Close the door and mark the inside vertical centerline of the garage door 2 Extend the line onto the header wall above the door You can fasten the header bracket within 4 feet 1 22 m of the left or right of the door center only if a torsion spring or center bearing plate is in the way or you can attach it to the ceiling see page 9 when clearanc
69. e chape de Anneau d arr t 5 16 po x 1 po Biellette droite Poign e de d clenchement d urgence Support de la porte ooo Biellette courb e Axe de chape de 5 16 po x 1 1 4 po Figure 1 Rondelle de blocage de 5 16 po Ecrous de 5 16 po 18 Support de Boulons hexagonaux de la porte 5 16 po 18 x 7 8 po Figure 2 de 5 16 po Ecrous de 5 16 po 18 T Boulons hexagonaux de 5 16 po 18 x 7 8 po Couper ce morceau Figure 3 POUR TOUTES LES PORTES RIGIDES 1 Assemblage des biellettes Figure 4 e Assembler les biellettes droite et courb e leur plus grande longueur 2 ou 3 trous se chevauchant e La porte tant ferm e raccorder la biellette droite au support de la porte l aide d un axe de chape de 5 16 po x 1 1 4 po Support de la porte o Anneau d arr t crous de 5 16 de po 18 Rondelles frein de 5 16 de po Axe de chape de Biellette 5 16 de po x 1 1 4 po droite Boulons de e Faire tenir l axe de chape avec un anneau d arr t 5 16 de po lt Biellette Figure 4 18 x 7 8 po courb e 2 M thodes de r glage Figure 5 Dans le cas d une porte rigide la course doit tre r gl e avant de raccorder la biellette au chariot Les vis de r glage de la course sont situ es sur le panneau du c t gauche comme illustr la page 23 Suivre les m thodes de r glage d taill es ci dessous e R glage de l o
70. e connection e Secure with a ring fastener e Run the opener through a complete travel cycle If the door has a slight backward slant in full open position as shown in the illustration decrease the UP limit until the door is parallel to the floor NOTE When setting the up limit on the following page the door should not have a backward slant when fully open as illustrated below A slight backward slant will cause unnecessary bucking and or jerking operation as the door is being opened or closed from the fully open position Closed Door Inner Trolley Emergency Release Handle Fully Open Trolley Correct Angle soto eet OTN D a CHE Bonn 72 22 gt wet Door with Door Arm Backward Slant D Open Boor Undesirable 22 ADJUSTMENT STEP 1 Adjust the UP and DOWN Travel Limits Limit adjustment settings regulate the points at which the door will stop when moving up or down To operate the opener press the Door Control push bar Run the opener through a complete travel cycle Does the door open and close completely e Does the door stay closed and not reverse unintentionally when fully closed If your door passes both of these tests no limit adjustments are necessary unless the reversing test fails Adjustment Step 3 page 25 Adjustment procedures are outlined below Read the procedures carefully
71. e d tecteur inverseur de s curit Ce dispositif de s curit requis NE DOIT PAS tre d sactiv Poser le d tecteur inverseur de s curit de mani re ce que le faisceau NE SOIT PAS UNE HAUTEUR de plus de 6 po 15 cm au dessus du plancher du garage Si les unit s doivent tre mont es sur le mur les supports doivent tre fix s fermement une surface solide telle que la charpente du mur On peut se procurer des supports de rallonge se reporter la section accessoires au besoin Si la pose se fait dans une construction en ma onnerie ajouter un morceau de bois chaque endroit pour viter de percer des trous suppl mentaires dans la ma onnerie si un repositionnement est n cessaire Il ne doit y avoir aucun obstacle sur le parcours du faisceau de lumi re invisible Aucune partie de la porte de garage ni les guides les ressorts les charni res les rouleaux ou autres fixations de la porte ne doit interrompre le faisceau pendant que la porte se ferme Sr o oo Vv 9 9 zi iy 9 9 9 o iy 9 0 0 i FL Faisceau du d tecteur Zone de protection du 6 po 15 cm max faisceau lumineux invisible au dessus du sol Faisant face la porte depuis l int rieur du garage 11 Faisceau du d tecteur 6 po 15 cm max au dessus du sol POSE DES SUPPORTS S assurer que l ouvre porte e
72. e is minimal It may be mounted on the wall upside down if necessary to gain approximately 1 2 1 cm If you need to install the header bracket on a 2x4 on wall or ceiling use lag screws not provided to securely fasten the 2x4 to structural supports as shown here and on page 8 3 Open your door to the highest point of travel as shown Draw an intersecting horizontal line on the header wall above the high point e 3 7 5 cm above the high point for sectional door and one piece door with track e 8 20 cm above the high point for one piece door without track This height will provide travel clearance for the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 12 for ceiling installation Unfinished OPTIONAL Highest Point of Travel Hardware Header Wall 8 20 cm Sectional door with curved track Highest Point 77 Jof Travel One piece door jamb hardware without track Ceiling CEILING MOUNT FOR HEADER BRACKET Header Wall Vertical Centerline of Garage Door Structural Supports e 5 f Dy yy Ss 0 Level if D D eh ee VA i OX HO A A i Header Wall Z T3 7 5 cm Track g 7a _ p Highest Point of Travel Highest Point of Tra
73. e la porte 4 Lorsque l clairage de l ouvre porte clignote rel cher tous les boutons Bouton poussoir Bouton de blocage Bouton d clairage B Pour actionner une porte en utilisant les trois boutons de la t l commande main ouverture fermeture arr t Ouverture Fermeture On peut programmer la Arr t t l commande pour ouvrir la porte avec le gros bouton fermer le porte avec le bouton du milieu et arr ter la porte avec le troisi me bouton REMARQUE Si la t l commande est d j programm e on doit d abord effacer tous les codes Voir Programmation 1 La porte tant ferm e enfoncer et tenir le gros bouton poussoir de la t l commande Continuer tenir tout en enfon ant le bouton de blocage sur la commande de porte Continuer tenir les deux boutons tout en enfon ant la barre poussoir de la commande de porte Lorsque l clairage de l ouvre porte clignote rel cher tous les boutons AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite de la chute d une porte de garage e Si possible utiliser la poign e de d clenchement d urgence pour d gager le chariot UNIQUEMENT lorsque la porte de garage est FERMEE Des ressorts faibles ou bris s ou une porte d s quilibr e peuvent causer la chute rapide ou impr vue d une porte ouverte e Ne JAMAIS utiliser la poign e de d clenchement d urgence moins que l entr e de
74. e porte murale e en vue de la porte de garage e hors de la port e des enfants une hauteur minimum de 5 pieds 1 5 m e l cart de toutes les pi ces mobiles de la porte Placer l tiquette d avertissement de prise au pi ge sur le mur c t de la commande de la porte de garage Placer l tiquette d essai d inversion de s curit ouverture manuelle bien en vue l int rieur de la porte de garage Au terme de la pose faire l essai du syst me d inversion de s curit La porte DOIT remonter au contact d un objet d une hauteur de 1 1 2 po 3 8 cm ou un 2 x 4 pos plat sur le sol POSE 1 OPERATION Plafond D terminer l emplacement du support a de linteau AVERTISSEMENT an Pour pr venir d ventuelles BLESSURES GRAVES ou Ligne du centre vertical de la LA MORT porte de garage e Le support de linteau DOIT tre fix DE MANIERE RIGIDE 2x4 la solive sur le linteau ou le plafond sinon la porte de garage pourrait ne pas remonter au besoin NE PAS poser le support de linteau sur des plaques de placopl tre SE On DOIT utiliser des ancrages de b ton pour le montage du e MONTAGE DU SUPPORT DE LINTEAU AU PLANFOND EN OPTION Solives support de linteau ou d un 2 x 4 dans la ma onnerie Ne JAMAIS tenter de desserrer d placer ou r gler la porte ITS de garage ainsi que les ressorts c bles poulies supports de TS porte ou leurs ferrures de montage lesquels
75. e son choix sur le pav num rique Enfoncer et tenir ensuite le bouton ENTER 3 Rel cher le bouton lorsque l clairage du moteur clignote Il a z appris le code Si les ampoules ne _ 2 sont pas pos es deux clics se feront entendre Pour modifier un NIP connu existant Si le NIP existant est connu il peut tre modifi par une seule personne sans devoir utiliser d chelle 1 Appuyer sur les quatre boutons correspondant au NIP actuel puis enfoncer et tenir le bouton L clairage de l ouvre porte clignotera deux fois Relacher le bouton 2 Introduire le nouveau NIP a 4 chiffres choisi puis appuyer sur ENTER L clairage du moteur clignotera une fois lorsque le NIP aura t appris Faire un essai en introduisant le nouveau NIP puis appuyer sur ENTER La porte devrait bouger Pour d finir un NIP temporaire Vous pouvez autoriser l acc s aux visiteurs ou aux techniciens de service l aide d un NIP temporaire a 4 chiffres Apr s un nombre programm d heures ou un nombre programm d utilisations ce NIP temporaire vient a expiration et n ouvre plus la porte On peut l utiliser pour fermer la porte une fois qu il a expir Pour d finir un NIP temporaire 1 Appuyer sur les quatre boutons correspondant a son NIP d entr e personnelle non le dernier NIP temporaire puis enfoncer et tenir le bouton L clairage de l ouvre porte clignotera trois fo
76. ed by one person without using a ladder 1 Press the four buttons for the present PIN then press and hold the button The opener light will blink twice Release the button 2 Press the new 4 digit PIN you have chosen then press Enter The motor unit lights will blink once when the PIN has been learned Test by pressing the new PIN then press Enter The door should move To set a temporary PIN You may authorize access by visitors or service people with a temporary 4 digit PIN After a programmed number of hours or number of accesses this temporary PIN expires and will no longer open the door It can be used to close the door even after it has expired To set a temporary PIN 1 Press the four buttons for your personal entry PIN not the last temporary PIN then press and hold the button The opener light will blink three times Release the button 32 USING THE MULTI FUNCTION DOOR CONTROL NOTE This method requires two people if the Keyless Entry is already mounted outside the garage Enter a four digit personal identification number PIN of your choice on the keypad Then press and hold ENTER N While holding the ENTER button press and hold the LIGHT button on the Multi Function Door Control w Continue holding the ENTER and LIGHT buttons while you press the push bar on the Multi Function D
77. emporary password for visitors or service persons This temporary password can be limited to a programmable number of hours or entries 395LMC 371LMC 372LMC M N 373LMC 374LMC 370LMC 916LMC 35 Remote Light Control Enables homeowner to turn on a lamp television or other appliance from their car with their garage door opener remote or from anywhere in their home with an additional LiftMaster Security remote 1 Button Security Remote Control Includes visor clip 2 Button Security Remote Control Includes visor clip 3 Button Security Remote Control Includes visor clip 4 Button Security Remote Control Includes visor clip 3 Button Mini Remote Control with Security With key ring and fastening strip Garage Door Monitor Security for the largest door of your homel Tells you if your garage door is open or closed Monitors up to 4 garage doors by adding additional sensor modules Garage Door Monitor Sensor Additional accessory sensor for homes with multiple garage doors LIFTMASTER SERVICE IS ON CALL OUR LARGE SERVICE ORGANIZATION SPANS AMERICA AND CANADA INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE SEVEN DAYS A WEEK SIMPLY DIAL OUR TOLL FREE NUMBER 1 800 654 4736 HOURS Central Std Time 6 00 A M TO 7 00 P M Monday through Friday 8 00 A M TO 6 00 P M Saturday 8 00 A M TO 4 30 P M Sunday HOW TO ORDE
78. en pause signifying it has found a potential issue Consult Diagnostic Chart below Diagnostic Chart Symptom One or both of the Indicator lights on the safety sensors do not glow steady Safety sensors wire open e Inspect sensor wires for a short staple in wire correct wiring polarity broken or disconnected black white wires reversed broken or disconnected wires replace attach OR as needed e Disconnect all wires from back of motor unit 2 FLASHES Remove sensors from brackets and shorten sensor wires to 1 2 ft 30 60 cm from back each of sensor Safety sensors wire e Reattach sending eye to motor unit using shortened wires If sending eye shorted or black white indicator light glows steadily attach the receiving eye wire reversed e Align sensors if the indicator lights glow replace the wires for the sensors If the sensor indicator lights do not light replace the safety sensors 3 FLASHES ea Symptom LED is not lit on door control e Inspect door control wires for a short staple in wire replace as needed Door control or wire shorted e Disconnect wires at door control touch wires together If motor unit activates replace door control e If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires 4 FLASHES Ss S
79. eneeeeeees 14 Hang the opener eee eeeceeeeeeeeeeeeeeeneeeeeseeeeeeeeeeeaaeees 15 Install the door control 16 Install the lights scaena 17 Attach the emergency release rope and handle 17 Electrical requirements 18 Complete safety reversing sensor installation 18 Fasten the door bracket 19 20 Connect the door arm to the trolley 06 21 22 INTRODUCTION Safety Symbol and Signal Word Review Adjustment 23 25 Adjust the travel limits 23 Adjust the force 00 cceeeceeeeeeeenneeeeeeenneeeeetenneeeeeeneea 24 Test the safety reversal system 25 Test the Protector System 25 Operation 26 30 Operation safety instructions 26 Using your garage door Opener 26 Using the wall mounted door control 27 To open the door manually 27 Care of your garage door opener 28 Having a problem eceeeeeeeeenneeeeeeeenteeeeeeenaeeees 29 Diagnostic chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 00 0 2 eeeccceeeeeeeceeeeeeeeeeeeeeeseneeeenteee 31 8 Button remotes 31 To add reprogram or change a Keyless Entry PIN 32 Repair Parts 33 34 Rail assembly parts 33 Installation parts 33 Motor unit assembly parts 34 Accessories 35 Repair
80. eposer sur un escabeau Si l escabeau n est pas assez haut demander de l aide e Ouvrir compl tement la porte et mettre un 2 x 4 de c t sur le dessus de la porte sous le rail e Le haut de la porte doit tre a la m me hauteur que le dessus du moteur Ne pas positionner l ouvre porte plus de 4 pouces 10 cm au dessus de ce point Le 2x4 est utilis pour d terminer la hauteur de fixation correcte partir du plafond 14 POSE 6 OPERATION Accrochage de l ouvre porte Les illustrations repr sentent trois poses types La pose peut toutefois tre diff rente Les supports de suspension doivent tre inclin s Figure 1 pour assurer un support rigide Dans le cas d un plafond fini Figure 2 fixer une corni re aux solives du plafond avant de poser l ouvre porte La corni re et les fixations ne sont pas fournies Les supports encore en place a la suite d une installation ant rieure peuvent tre attach s aux c t s du bloc moteur comme illustr aux figures 1 et 2 ou aux languettes de montage comme illustr la figure 3 Poursuivez ensuite avec l tape 5 ci apr s 1 Retirer la mousse de conditionnement Mesurer de chaque c t de l ouvre porte la distance entre l ouvre porte et les solives 2 Couper les deux supports de suspension la longueur requise 3 Percer des avant trous de 3 16 pouce dans les solives 4 Fixer une extr mit de chaque supp
81. eption sp ciale Peut galement ajouter un code temporaire pour les visiteurs ou les pr pos s au service Ce code programmable peut tre limit un nombre programmable d heures ou d entr es 395LMC 371LMC 372LMC 373WC Q 35 374LMC 370LMC 916LMC Commande d clairage Permet d allumer une lampe un t l viseur ou un autre appareil a partir de la voiture avec l ouvre porte ou a partir de n importe ou dans la maison avec une autre t l commande LiftMaster Security T l commande a 1 touche avec Security Comprend l agrafe de pare soleil T l commande a 2 touches avec Security Comprend l agrafe de pare soleil T l commande noyer 3 touches avec Security Comprend l agrafe de pare soleil T l commande a 4 touches avec Security Comprend l agrafe de pare soleil Mini t l commande 3 touches avec Security Avec porte cl et ruban d attache Systeme de d tection d ouverture de porte de garage Permet de surveiller la plus grande porte de votre domicile Indique si la porte du garage est ouverte ou ferm e Peut surveiller jusqu 4 portes de garage avec des moniteurs suppl mentaires Moniteur de porte de garage Moniteur suppl mentaire pour les domiciles qui comptent plusieurs portes de garage L ENTRETIEN LIFTMASTER EST A VOTRE DISPOSITION PAR TELEPHONE NOTRE VASTE ORGANISATION DE SERVICE AP
82. er une prise de courant ad quate Si les codes municipaux exigent une installation lectrique permanente proc der comme suit Pour proc der un branchement permanent par le trou de 7 8 po pratiqu au dessus du moteur e Retirer les vis du couvercle du moteur et mettre le couvercle de c t e D brancher le cordon 3 fils e Brancher le fil noir courant secteur sur la vis de la borne en laiton le fil blanc neutre sur la vis de la borne en argent puis le fil de terre sur la vis verte de terre L ouvre porte doit obligatoirement tre mis la terre e Reposer le couvercle Pour viter les difficult s pendant la pose ne pas faire fonctionner l ouvre porte avant l tape 11 POSE 11 OP RATION Compl tion de l installation du d tecteur d inversion assurant la s curit ALIGNEMENT DES D TECTEURS INVERSEURS Brancher l ouvre porte dans la prise de courant Les t moins des cellules mettrice et r ceptrice s allumeront et resteront allum s si les connexions lectriques sont bonnes et si l alignement est bon Le t moin lumineux ambre de la cellule mettrice s allumera ind pendamment de l alignement ou de obstruction Si le t moin lumineux vert de la cellule r ceptrice est teint faible ou clignotant et que la trajectoire du faisceau lumineux invisible n est pas obstru e aligner les deux d tecteurs e Desserrer l crou de la cellule mettrice et ajuster de fa on
83. et il _ 7 non fournis Boulon de 5 16 po 18 x 7 8 po Rondelle de blocage 5 16 po Ecrou de 5 16 po 18 Corni re non fournie Rondelle de blocage 5 16 po Ecrou de 5 16 po 18 R gion pr f r e de positionnement des supports Figure 3 Languettes de montage Corni re fournie Utilisation d une installation existante 15 POSE 7 OPERATION Pose de la commande de porte Poser la commande murale dans un endroit o on pourra la voir de la porte au moins 5 pieds 1 5 m du sol l o les enfants ne pourront pas l atteindre et loin de toutes les pi ces mobiles et fixations de la porte La surface de montage doit tre lisse et plate Si les murs sont des murs secs percer des trous de 5 32 pouce Figure 1 et utiliser les chevilles fournies Pour les installations pr cabl es comme dans la construction d une maison neuve on peut la monter sur une bo te simple Figure 2 REMARQUE Apr s l installation un t moin lumineux vert derri re le couvercle indiquera un branchement appropri S il n est pas allum les fonctions de blocage et d clairage ne fonctionneront pas inverser les fils pour corriger 1 D nuder 7 16 11 mm pouce a chaque extr mit des fils de sonnerie brancher les fils sur les deux bornes filet es qui se trouvent l arriere de la commande murale blanc a 2 blanc rouge 1 Figure 3 Commande clair e de porte Fixer au mur l aide de vi
84. et bien align s avant que l ouvre porte de garage puisse fermer la porte INFORMATIONS IMPORTANTES AU SUJET DU DETECTEUR INVERSEUR DE SECURITE Lorsqu il est bien raccord et align le d tecteur d tecte un obstacle dans le parcours de son faisceau lectronique La cellule mettrice avec un t moin lumineux ambre transmet un faisceau de lumi re invisible a la cellule r ceptrice avec un t moin lumineux vert Si un obstacle brise le faisceau de lumi re pendant que la porte se ferme la porte s arr tera et remontera jusqu a la position enti rement ouverte et les lumi res de l ouvre porte clignoteront 10 fois Les unit s doivent tre pos es l int rieur du garage de mani re ce que la cellule mettrice et la cellule r ceptrice se fassent face l une l autre de part et d autre de la porte pas plus de 6 po 15 cm au dessus du sol Lune ou l autre peut tre pos e gauche ou droite de la porte pourvu que le soleil n claire jamais directement dans la cellule r ceptrice Les supports de montage sont con us en vue de leur fixation par pince sur le guide des portes de garage articul es sans fixations suppl mentaires AVERTISSEMENT e S assurer que ouvre porte de garage est hors tension AVANT de poser le d tecteur inverseur de s curit e Pour pr venir des BLESSURES GRAVES ou LA MORT par suite d une porte de garage qui se ferme Raccorder et aligner correctement l
85. f the following e The hand held Remote Control Hold the large push button down until the door starts to move e The wall mounted Door Control Hold the push button or bar down until the door starts to move e The Keyless Entry See Accessories f provided with your garage door opener it must be programmed before use See Programming When the opener is activated with the safety reversing sensor correctly installed and aligned 1 If open the door will close If closed it will open 2 If closing the door will reverse 3 If opening the door will stop 4 If the door has been stopped in a partially open position it will close 5 If obstructed while closing the door will reverse If the obstruction interrupts the sensor beam the opener lights will blink for five seconds 26 8 NEVER use handle to pull garage door open or closed If rope knot becomes untied you could fall If one control force or travel limits is adjusted the other control may also need adjustment After ANY adjustments are made the safety reversal system MUST be tested Safety reversal system MUST be tested every month Garage door MUST reverse on contact with 1 1 2 3 8 cm high object or a 2 x 4 laid flat on the floor ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED see page 3 An improperly balanced door may not reverse when required and could result in SEVERE INJURY or DEATH All repairs to cables spring assemblies and other
86. ffres correspondant ce NIP temporaire puis appuyer sur ENTER La porte devrait bouger Si le NIP temporaire a t d fini pour un certain nombre d ouvertures ne pas oublier que le test a utilis une ouverture Pour effacer le mot de passe temporaire r p ter les tapes 1 3 en d finissant le nombre d heures ou de fois 0 lors de l tape 3 PIECES DE REPARATION Pi ces d assemblage du rail REF PIECE DESIGNATION 41A4795 Sac de mat riel comprend un coupleur de pignon 12B569 1 Support de rail gauche 12B569 2 Support de rail droit 810168 Support 4104677 Ensemble de chariot complete 1D4828 1 Rail monopi ce a entrainement filet 41A4836 Kit de pignon d entra nement 25C20 Coupleur de pignon Pi ces pour la pose N DE i REF PIECE DESIGNATION 41A5273 1 Panneau commande de porte multifonction 41A4166 Bouton poussoir clair dela commande de porte 41A2828 Poign e et corde pour fonctionnement d urgence 371LMC Bo tier de t l commande un bouton 373LMC T l commande a trois boutones 10A20 Pile au lithium 3V2032 29B137 Agrafe de pare soleil de la t l commande 41A5047 Support de porte avec axe de chape et fixation 178B34 Biellette droite 41A4353 Support de linteau avec axe de chape et fixation 41A5034 N cessaire de capteur de s curit cellules de r ception et de transmission avec fil de sonnerie a deux conducteurs de 3 pi 41A5266 1 Supports de d tecteurs inverseurs de
87. from each side of the motor unit to the structural support 2 Cut both pieces of the hanging bracket to required lengths 3 Drill 3 16 pilot holes in the structural supports 4 Attach one end of each bracket to a support with 5 16 18x1 7 8 lag screws 5 Fasten the opener to the hanging brackets with 5 16 18x7 8 hex bolts lock washers and nuts If you wish to utilize the two center mounting tabs you must triangulate the vertical brackets for additional stability Figure 3 6 Check to make sure the rail is centered over the door or in line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket HARDWARE SHOWN ACTUAL SIZE Lag Screw 5 16 18x1 7 8 i Hex Bolt 5 16 18x7 8 Nut 5 16 18 Lock Washer 5 16 WARNING To avoid possible SERIOUS INJURY from a falling garage door opener fasten it SECURELY to structural supports of the garage Concrete anchors MUST be used if installing any brackets into masonry Structural Figure 1 Supports Lag Screws 5 16 18x1 7 8 Measure Distance Hex Bolt 5 16 18x7 8 Lock Washers 5 16 Nuts 5 16 18 Preferred range of bracket placement Figure 2 FINISHED CEILING Hidden oe TT er Lag Screws 5 16 18x1 7 8 Bracket Not Provided Not Provided Bolt 5 16 18x7 8 Lock Washer 5 16
88. garage ne soit d gag e absence de personnes et d obstacles e Ne JAMAIS utiliser la poign e pour ouvrir ou fermer la porte Il y a risque de chute si le n ud de la corde se d fait Ouverture manuelle de la porte POUR D GAGER LE CHARIOT Dans la mesure du possible la porte U Co eraot doit tre compl tement ferm e Tirer Teves la poign e de d clenchement 8 N d clenchement du chariot d urgence vers le bas afin que la biellette de d gagement du chariot s enclenche dans une position verticale et lever la porte manuellement J en position de d tachement manuel LS Position de d branchement manuel La fonction de verrouillage emp che le chariot de se r enclencher automatiquement sera alors possible d ouvrir et de fermer la porte la main autant de fois qu on le d sirera POUR R ENCLENCHER LE CHARIOT U o J Chariot Tirer la poign e de d clenchement Boo ay Levier de d clenchement d urgence vers le bas et l arri re vers l ouvre porte de garage un angle de 45 afin que la biellette de d gagement du chariot soit en position horizontale Le chariot se Poign e de d clenchement Ss chariot d urgence tirez suivant un trez Es de 45 degr s Position verrouillage r enclenchera lors de la prochaine ouverture ou fermeture de la porte manuelle ou l aide de la commande de porte ou t
89. i autotaraudeuse v 1 4 po 14 x 5 8 po Figure 4 Figure 3 PORTES RIGIDES Pri re de lire et de suivre les avertissements et les instructions de renforcements a la page pr c dente Ils s appliquent galement aux portes rigides e Centrer le support de porte sur le dessus de la porte en l alignant avec le support de linteau comme il est illustr Rep rer soit les trous de gauche et de droite soit les trous du haut et du bas Portes m talliques Percer des avant trous de 3 16 pouce puis fixer le support de la porte l aide des vis autotaraudeuses de 1 4 po 14 x 5 8 po fournies e Portes en bois Percer des trous de 5 16 po et utiliser des boulons t te bomb e et collet carr de 5 16 po x 2 po des rondelles de blocage et des crous non fournis ou des tire fond de 5 16 po x 1 1 2 po non fournis suivant les besoins particuliers de l installation GRANDEUR R ELLE DES FIXATIONS Vis autotaraudeuse 1 4 de po 14 x 5 8 de po REMARQUE Le support de porte peut tre pos sur le bord sup rieur de la porte si n cessaire pour une installation particuli re Se reporter au dessin du positionnement facultatif la ligne pointill e Vis P autotaraudeuse de J 1 4 po 14 x 5 8 po Dessus de la porte int rieur du garage Support de la porte S Linteau Support 2 x 4 Plafond fini Bord sup rieur de la porte Placement facultatif de la porte
90. ilibr e et qu il n y a pas de probl mes d adh sion e Se reporter la 2 op ration de r glage R glage de la force 4 Apr s fermeture compl te et apr s contact avec le sol la porte inverse sa course sans raison apparente R p ter le contr le de l inversion de s curit apr s avoir proc d au r glage de la force ou des limites de course Le besoin de proc der des r glages occasionnels des limites de courses et de la force est normal Les variations saisonni res en particulier peuvent alt rer la course de la porte e Se reporter la 1 op ration de r glage R glage des courses d OUVERTURE et de FERMETURE Diminuer la course de fermeture en tournant les vis de r glage dans le sens horaire LED ou LED diagnostic Cellule mettrice de d tecteur inverseur T moin lumineux ambre Cellule r ceptrice de d tecteur inverseur T moin lumineux vert 5 L clairage ne s teint pas quand la porte est ouverte e L ouvre porte de garage est quip d un clairage de s curit Cette caract ristique allume la lumi re quand le faisceau lumineux de s curit a t obstru Se reporter la section Fonctionnement Utilisation de a commande murale de luxe Fonction d clairage 29 Montage du d tecteur inverseur Diagnostic situ sur le moteur
91. ing Failure to comply strictly with those instructions will void this warranty in its entirety Please note that the safety reverse system in order to operate properly with your garage door must be adjusted and periodically tested in accordance with the Owner s Manual If during the limited warranty period it appears as though this product contains a defect which is covered by this limited warranty call our toll free service number before dismantling this product at 1 800 654 4736 Then send this product pre paid and insured to our service center for warranty repair You will be advised of shipping instructions when you call the toll free service number Please include a brief description of the problem and a dated proof of purchase receipt with any product that is returned for warranty repair Products returned to Seller for warranty repair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Seller s sole option THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE AND OF ANY OTHER OBLIGATIONS OR LIABILITY ON SELLER S PART THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY
92. int de course le plus haut tel f qu illustr Tracer une ligne horizontale d intersection Porte articul e avec guide courb Porte rigide avec guide horizontal sur le linteau au dessus du point le plus haut e 3 po 7 5 cm au dessus du point le plus haut pour portes articul es et portes rigides avec rail e 8 po 20 cm au dessus du point le plus haut pour portes rigides sans rail Linteau Linteau 8 po 20 cm Cette hauteur permettra d obtenir un d gagement 8 po 20 cm PR suffisant pour le passage de la partie sup rieure de Bees y 3 AN la porte lt Point de course i ee i mal REMARQUE Si le nombre total de pouces Es nau Pore d XX Li le plus haut x z d Eti 1 centim tres d passe la hauteur disponible dans le We n garage utiliser la hauteur maximum ou se reporter la 1 i page 12 pour la pose au plafond Ferrure de el EErcEr ce montant Pivot Porte rigide sans guides Porte rigide sans guides ferrure de montant basculant sur pivots POSE 2 OPERATION Pose du support de linteau Le support de linteau peut tre fix soit sur le mur au dessus de la porte soit sur le plafond Suivre les instructions qui r pondent le mieux aux besoins particuliers Ne pas poser le support de linteau sur des plaques de placopl tre Utiliser des ancrages de b ton non fournis pour la pose dans la ma onnerie POSE DU SUPPORT DE LINTEAU
93. is Rel cher le bouton 32 REMARQUE Cette m thode n cessite deux personnes si le pav pour l entr e sans cl est d j mont l ext rieur du garage 1 Introduire un num ro d identification personnelle NIP a quatre chiffres de son choix sur le pav num rique Enfoncer et tenir ensuite le bouton ENTER 2 Tout en maintenant le bouton ENTER enfonc appuyer et tenir le bouton LIGHT de la commande de porte Multifonction 3 Maintenir les deux boutons enfonc s tout en appuyant sur le bouton poussoir de la commande de porte Multifonction les trois boutons sont tenus 4 Relacher les boutons lorsque l clairage du moteur clignote Il a Ke appris le code Si les ampoules ne sont pas pos es deux clics se N feront entendre 2 Introduire le NIP temporaire 4 chiffres choisi puis appuyer sur ENTER L clairage de l ouvre porte clignotera quatre fois 3 Pour d finir le nombre d heures de validit de ce NIP temporaire appuyer sur le nombre d heures jusqu 255 puis appuyer sur OU 3 Pour d finir le nombre de fois de validit de ce NIP temporaire appuyer sur le nombre de fois jusqu a 255 puis appuyer sur L clairage de l ouvre porte clignotera une fois lorsque ce NIP temporaire aura t appris Faire un essai en entrant les quatre chi
94. lbs are not installed 10 clicks can be heard See page 11 INSTALLATION STEP 12 Fasten the Door Bracket Follow instructions which apply to your door type as illustrated below or on the following page A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports A vertical reinforcement brace should cover the height of the top panel Figure 1 shows one piece of angle iron as the horizontal brace For the vertical brace 2 pieces of angle iron are used to create a U shaped support The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit NOTE Many door reinforcement kits provide for direct attachment of the clevis pin and door arm In this case you will not need the door bracket proceed to Step 13 SECTIONAL DOORS 1 Center the door bracket on the previously marked vertical centerline used for the header bracket installation Note correct UP placement as stamped inside the bracket 2 Position the top edge of the bracket 2 4 5 10 cm below the top edge of the door OR directly below any structural support across the top of the door 3 Mark drill holes and install as follows depending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket e Drill 3 16 fastening holes Secure the door bracket using the two 1 4 14x5 8
95. le de 1 4 po 20 x 5 8 po Rail GRANDEUR R ELLE DES FIXATIONS Boulon t te hexagonale crou de de 1 4 po 20 x 5 8 po 1 4 po 20 TITI IMPORTANTES INSTRUCTIONS CONCERNANT LA POSE amp AVERTISSEMENT Pour r duire le risque de BLESSURES GRAVES ou MORTELLES LIRE ET SUIVRE TOUS LES AVERTISSEMENTS ET INSTRUCTIONS DE POSE Poser l ouvre porte de garage uniquement sur une porte de garage bien quilibr e et lubrifi e Une porte mal quilibr e peut ne pas remonter au besoin et pourrait provoquer des BLESSURES GRAVES ou LA MORT Toutes les r parations aux c bles ensembles de ressort et autres ferrures de montage DOIVENT tre confi es un technicien form en syst mes de porte AVANT de poser l ouvre porte D sactiver toutes les serrures et retirer toutes les cordes raccord es a la porte de garage AVANT de poser l ouvre porte afin d viter un emm lement Poser l ouvre porte de garage au moins 7 pieds 2 13 m au dessus du sol Monter la poign e de d clenchement d urgence a 6 pieds 1 83 m au dessus du sol Ne JAMAIS raccorder l ouvre porte de garage une source de courant avant d avoir re u l instruction de le faire 8 Ne JAMAIS porter de montres bagues ou v tements amples durant la pose ou l entretien de ouvre porte Ils pourraient tre happ s par la porte de garage ou les m canismes de l ouvre porte Poser la commande d
96. llowing warnings before proceeding to the installation section INSTALLATION Lock Nuts 1 4 20 Rail Brackets Hex Bolts SX 1 4 20x5 8 Rail HARDWARE SHOWN ACTUAL SIZE Hex Bolt Lock Nut 1 4 20 x 5 8 1 4 20 TN p IMPORTANT INSTALLATION INSTRUCTIONS amp WARNING To reduce the risk of SEVERE INJURY or DEATH READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS Install garage door opener only on properly balanced and lubricated garage door An improperly balanced door may not reverse when required and could result in SEVERE INJURY or DEATH All repairs to cables spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener Disable all locks and remove all ropes connected to garage door BEFORE installing opener to avoid entanglement Install garage door opener 7 feet 2 13 m or more above floor Mount emergency release handle 6 feet 1 83 m above floor NEVER connect garage door opener to power source until instructed to do so 8 NEVER wear watches rings or loose clothing while installing or servicing opener They could be caught in garage door or opener mechanisms Install wall mounted garage door control e within sight of the garage door e out of reach of children at minimum height of 5 feet 1 5 m e away from all moving parts of the door Place entrapment warning label on wall next to garag
97. mark no more than 6 15 cm from the wall Make sure the arrow is pointing toward the wall The bracket can be ee Finished Ceiling mounted flush against the ceiling when clearance a ed Vertical 2 7 Header Centerline is minimal a a Bracket Of Garage Door e Mark the side holes Drill 3 16 pilot holes and l yer fasten bracket securely to a structural support with the hardware provided Ceiling Mounting Holes CEILING MOUNK ONLY The nail hole is for positioning only You must use lag screw to mount the header bracket Garage Door of Garage Door INSTALLATION STEP 3 Attach the Rail to the Header Bracket e Position the opener on the garage floor below the header bracket Use packing material as a protective base NOTE If the door spring is in the way you ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring e Position the rail bracket against the header bracket Header Wall F ic A Header Bracket e Align the bracket holes and join with a clevis pin Rail Bracket as shown Insert a ring fastener to secure Ring Fastener Header Bracket Clevis Pin 5 16 x2 3 4 Bracket Rail Garage Door Temporary Support HARDWARE SHOWN ACTUAL SIZE Clevis Pin 5 16 x2 3 4 Ring Fastener INSTALLATION STEP 4 Install The Protector System The safety reversing sensor mu
98. ment sur le pignon du rail e Glisser le rail travers le support du moteur jusqu ce que l accouplement soit bien connect sur le pignon du moteur x e Aligner les deux orifices de vis du rail ceux du support du moteur Ins rer deux boulons hexagonales de 1 4 po 20 x 5 8 po et leurs crous de blocage Serrer solidement avec une cl a douille de 7 16 po moteur Ecrous de blocage Accouplement Pignon de rail Boulon t te hexagonale de 1 4 po 20 x 5 8 po Emballage en mousse La fl che doit tre dirig e vers la porte de garage Biellette de d gagement MONTAGE 2 OPERATION Installation du chariot e Glissez le chariot par dessus le bas du rail jusqu ce qu il soit fix solidement en position S assurer qu il est install dans le bon sens la biellette de d gagement du chariot doit tre horizontale position verrouill e et la fl che doit pointer en direction oppos e du moteur MONTAGE 3 OPERATION Montage des supports de rail Ecrou de 1 4 po 20 Supports de rail e Alignez les supports de rail sur l extr mit du rail comme illustr e Ins rer deux boulons hexagonales de 1 4 po 20 x 5 8 po et leurs crous de blocage Serrer solidement avec une cl douille de 7 16 po Le montage de l ouvre porte de garage est maintenant termin Lire les avertissements suivants avant de proc der la section sur la pose POSE Boulon t te hexagona
99. nit then refer to Diagnostic Chart on the following page Diagnostic LED 5 My lights will not turn off when door is open e The garage door opener is equipped with a security light feature This feature activates the light on when the safety sensor beam has been obstructed Refer to Operation section Using the Wall Mounted Door Control Light Feature 3 My door reverses for no apparent reason Repeat safety reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel e Manually check door for balance or any binding problems Refer to Adjustment Step 2 Adjust the Force 4 My door reverses for no apparent reason after fully closing and touching the floor Repeat safety reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel e Refer to Adjustment Step 1 Adjust the UP and DOWN Travel Limits Decrease down travel by turning down limit adjustment screw clockwise 29 1 il my ae wel 2 nies a i Your garage door opener is programmed with L self diagnostic capabilities The Learn button diagnostic i 7 i j LED will flash a number of times th
100. nnels on top of rail 2 Run wires along channels to motor unit Use screwdrive blade to tuck snugly into channels 3 Pull wires taut across top of chassis and insert into opening above terminal block Figure 5 Wing Nut N 1 4 20 y EN Carriage Bolt _P NE 1 4 20x1 2 Lens HARDWARE SHOWN ACTUAL SIZE mw FA Carriage Bolt Wing Nut 1 4 20x1 2 1 4 20 Staples Header Wall Sensor Wire Sensor Wire Header Bracket a a ee a esse Ses pa PSS SS ET Invisible Light Beam Protection Area Sensor INSTALLATION STEP 5 Position the Opener To prevent damage to garage door rest garage door opener rail on 2x4 placed on top section of door CAUTION Follow instructions which apply to your door type as illustrated SECTIONAL DOOR OR ONE PIECE DOOR WITH TRACK A 2x4 laid flat is convenient for setting an ideal door to rail distance e Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough ii e Open the door all the way and place a 2x4 laid flat Doz rere on the top section beneath the rail a q F e If the top section or panel hits the trolley when you 2x4 is used to determine raise the door pull down on the trolley release arm Beor Les to disconnect inner and outer sections Slide the outer trolley toward the motor unit The trolley can remain disconnected until In
101. ol on screw head and slide down to secure Adjust screw for snug fit e Install top screw with care to avoid cracking plastic housing Do not overtighten e Insert bottom tabs and snap on cover NOTE The push bar may stick if the door control is not mounted on a smooth surface If a click is not heard when pressing the push bar loosen the two mounting screws or relocate the door control to a smoother surface 3 Standard installation only Run bell wire up wall and across ceiling to motor unit Use insulated staples to secure wire in several places Do not pierce wire with a staple creating a short or open circuit If your access door is near the garage door you may run this wire with the Safety Reversing Sensor wires along the top of the rail See page 13 4 Insert all wires through the opening on top of motor unit above the terminal block on the back panel Figure 4 5 Strip 7 16 11 mm of insulation from each set of wires Insert door control wire into quick connect terminals by color white wire to white white red wire to red Separate white and white black wires sufficiently to connect to the opener quick connect terminals Twist like colored wires together Insert wires into quick connect holes white to white and white black to grey Figure 4 NOTE When connecting multiple door controls to the opener twist same color wires together Insert wires into quick connect holes white to white and red white to red 6
102. oor Be sure there is enough clearance for the sensor beam to be unobstructed If additional depth is needed an extension bracket see accessories or wood blocks can be used e Use bracket mounting holes as a template to locate and drill 2 3 16 diameter pilot holes on the wall at each side of the door no higher than 6 15 cm above the floor e Attach brackets to wall with lag screws not provided If using extension brackets or wood blocks adjust right and left assemblies to the same distance out from the mounting surface Make sure all door hardware obstructions are cleared Floor installation Figure 4 e Use wood blocks or extension brackets see Accessories to elevate sensor brackets so the lenses will be no higher than 6 15 cm above the floor Carefully measure and place right and left assemblies at the same distance out from the wall Be sure all door hardware obstructions are cleared Fasten to the floor with concrete anchors as shown Figure 1 Figure 2 Figure 3 DOOR TRACK MOUNT RIGHT SIDE Indicator WALL MOUNT RIGHT SIDE Fasten Wood Block to Wall with Lag Screws Not Provided Indicator Sensor Bracket WALL MOUNT RIGHT SIDE Extension Bracket See Accessories Provided with Extension Bracket Sensor Provided with Az Bracket Extension ry Bracket Niel Indicator Lens Light Figure 4 FLOOR MOUNT RIGHT
103. oor Control all three buttons are held 4 Release buttons when the motor S unit lights blink It has learned the code If light bulbs are not K installed two clicks will be heard 2 Press the temporary 4 digit PIN you have chosen then press Enter The opener light will blink four times 3 To set the number of hours this temporary PIN will work press the number of hours up to 255 then press OR 3 To set the number of times this temporary PIN will work press the number of times up to 255 then press The opener light will blink once when the temporary PIN has been learned Test by pressing the four buttons for the temporary PIN then press Enter The door should move If the temporary PIN was set to a certain number of openings remember that the test has used up one opening To clear the temporary password repeat steps 1 3 setting the number of hours or times to 0 in step 3 REPAIR PARTS Rail Assembly Parts KEY PART NO NO DESCRIPTION 41A4795 Hardware bag includes sprocket coupling 12B569 1 Left rail bracket 12B569 2 Right rail bracket 810168 Rack 41C4677 Complete trolley assembly 1D4828 1 Screw Drive one piece rail 41A4836 Drive sprocket kit 25C20 Sprocket coupling Installation Parts KEY PART NO NO DESCRIPTION 41A5273 1 Multi function door control 41A4166 Lighted door control button 41A2828 Emergency release rope amp handle 371L
104. or exclusion may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from province to province LIMITED WARRANTY ON MOTOR Model 3220C The motor is fully warranted for the lifetime of the product to the first time purchaser Model 3110C The motor is warranted to be free from any defect in materials and or workmanship for a period of 24 full months 2 years from the date of purchase Eee eee eee eee eee eee eee eee eee eee eee eee eee et ete eel eee ee tee fl r 2006 The Chamberlain Group Inc 114A3182B All Rights Reserved CHAMBERLAIN The Chamberlain Group Inc 845 Larch Avenue Elmhurst Illinois 60126 1196 E as er www liftmaster com PROFESSIONAL SECURITY OUVRE PORTE DE GARAGE Mod les 3110C 1 3 HP 3220C 1 2 HP Pour r sidences seulement Manuel d instructions m Lire attentivement ce manuel ainsi que les consignes de s curit m Apr s la pose accrocher ce manuel pr s de la porte de garage pour s y reporter ult rieurement m La porte NE SE FERMERA PAS si le Syst me Protector n est pas branch et r gl correctement Pour un bon fonctionnement en toute s curit de cet ouvre porte de garage le v rifier et le r gler p riodiquement E L tiquette du num ro de mod le est situ e sur le panneau avant de votre ouvre porte TABLE DES MATIERES Introduction 2 5 Revue des symboles
105. ort de suspension sur une solive avec des tire fond de 5 16 po 18 x 1 7 8 po 5 Fixer l ouvre porte aux supports de suspension l aide de boulons hexagonaux de 5 16 po 18 x 7 8 po de rondelles de blocage et d crous Si vous d sirez utiliser les deux languettes de fixation centrales il est n cessaire de disposer les supports verticaux en triangle pour am liorer la stabilit Figure 3 6 S assurer que le rail est centr au dessus de la porte ou dans le prolongement du support de linteau si le support n est pas centr au dessus de la porte 7 Retirer le 2 x 4 Faire fonctionner la porte manuellement Si la porte frappe le rail lever le support de linteau GRANDEUR R ELLE DES FIXATIONS D00000000D Tire fond de 5 16 de po 18 x 1 7 8 de po Boulon hexagonal de 5 16 de po 18 x 7 8 de po crou de 5 16 de po 18 Rondelle frein de 5 16 de po AVERTISSEMENT Pour viter d ventuelles BLESSURES GRAVES par suite de la chute d un ouvre porte de garage fixer l ouvre porte SOLIDEMENT aux solives du garage On DOIT utiliser des ancrages de b ton si les supports sont pos s dans la ma onnerie Figure 1 Solives Tire fond de 5 16 po x 18 x 1 7 8 po Mesurer la distance Boulon de 5 16 po 18 x 7 8 po Rondelle de blocage 5 16 po Ecrou de 5 16 po 18 R gion pr f r e de positionnement des supports Figure 2 PLAFOND FINI Support cach yee gee er fe
106. ose cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to close the door 2 Test the UP open force e Grasp the door bottom when the door is about halfway through UP open travel The door should stop If the door is hard to hold or doesn t stop DECREASE UP open force by turning the control counterclockwise Make small adjustments until the door stops easily and opens fully After each adjustment run the opener through a complete travel cycle If the door doesn t open at least 5 feet 1 5 m INCREASE UP open force by turning the control clockwise Make small adjustments until door opens completely Readjust the UP limit if necessary After each adjustment run the opener through a complete travel cycle 24 WARNING Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e Too much force on garage door will interfere with proper operation of safety reversal system e NEVER increase force beyond minimum amount required to close garage door e NEVER use force adjustments to compensate for a binding or sticking garage door e If one control force or travel limits is adjusted the other control may also need adjustment e After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with
107. panel of the motor unit Force adjustment settings regulate the amount of power required to open and close the door If the forces are set too light door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction Weather conditions can affect the door movement so occasional adjustment may be needed The maximum force adjustment range is about 3 4 of a complete turn Do not force controls beyond that point Turn force adjustment controls with a screwdriver NOTE If anything interferes with the door s upward travel it will stop If anything interferes with the door s downward travel including binding or unbalanced doors it will reverse HOW AND WHEN TO ADJUST THE FORCES 1 Test the DOWN close force e Grasp the door bottom when the door is about halfway through DOWN close travel The door should reverse Reversal halfway through down travel does not guarantee reversal on a 1 1 2 3 8 cm obstruction See Adjustment Step 3 page 25 If the door is hard to hold or doesn t reverse DECREASE the DOWN close force by turning the control counterclockwise Make small adjustments until the door reverses normally After each adjustment run the opener through a complete cycle e If the door reverses during the down close cycle and the opener lights aren t flashing INCREASE DOWN close force by turning the control clockwise Make small adjustments until the door completes a cl
108. porte de garage g nera un fonctionnement appropri du syst me d inversion de s curit e Apr s avoir r gl une commande force ou course il peut tre n cessaire de r gler l autre commande e Apr s avoir effectu quelque r glage que ce soit on DOIT faire l essai du syst me d inversion de s curit La porte de garage DOIT remonter au contact d un objet d une hauteur de 1 1 2 po 3 8 cm ou un 2 x 4 pos plat sur le sol ATTENTION Pour pr venir les dommages aux v hicules s assurer que la porte enti rement ouverte offre un d gagement suffisant OO0O0000 0 Vis de r glage de course Panneau c t gauche t R glage de la course A vers le HAUT y R glage de la course vers le BAS e Sila porte remonte en cours de fermeture sans qu il n y ait d obstacles visibles qui la g nent Si les lumi res de l ouvre porte clignotent ceci signifie que les d tecteurs inverseurs de s curit ne sont pas install s sont mal align s ou sont obstru s Se reporter la section D pannage la page 18 V rifier si la porte force Tirer la poign e de d clenchement d urgence Ouvrir et fermer manuellement la porte Si la porte force appeler un technicien form en syst mes de porte Si la porte est quilibr e et ne force pas ajuster la force de fermeture Se reporter la 2 op ration des r glages REGLAGE
109. puis enfoncer et tenir le bouton d clairage pendant 10 secondes jusqu ce que les lumi res s teignent puis s allument nouveau Utilisation de la commande de porte a montage mural Appuyer sur le bouton poussoir pour ouvrir 2 Bouton poussoir 0 ou fermer la porte Appuyer nouveau pour faire remonter la porte lors du cycle de fermeture ou pour arr ter la porte pendant le cycle d ouverture PANNEAU COMMANDE DE PORTE Appuyer sur la barre pour ouvrir ou fermer la porte Appuyer nouveau pour faire remonter la porte lors du cycle de fermeture ou pour arr ter la porte pendant le cycle d ouverture Fonction d clairage Appuyez sur le bouton d clairage pour allumer ou teindre l clairage de l ouvre porte Il ne contr le pas l clairage de l ouvre porte pendant que la porte est en mouvement Si vous allumez puis activez l ouvre porte l clairage demeurera allum pendant 4 1 2 minutes Appuyez nouveau sur ce bouton pour l teindre plus t t Lintervalle de 4 1 2 minutes peut tre chang 1 1 2 2 1 2 ou 3 1 2 minutes comme suit Enfoncer et tenir le bouton de blocage jusqu ce que l clairage clignote environ 10 secondes Un seul clignotement indique que la minuterie est r gl e 1 1 2 minute R p ter la proc dure et l clairage clignotera deux fois r glant ainsi la minuterie 2 1 2 minutes R p ter nouveau pour un intervalle de 3 1 2 minutes etc jusqu
110. r One Piece Door Carpenter s Level Optional 3 16 5 16 and 5 32 Drill Bits w 1 2 and 7 16 Sockets and Wrench To prevent possible SERIOUS INJURY or DEATH e ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door may not reverse when required e NEVER try to loosen move or adjust garage door door springs cables pulleys brackets or their hardware all of which are under EXTREME tension e Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement CAUTION To prevent damage to garage door and opener e ALWAYS disable locks BEFORE installing and operating the opener ONLY operate garage door opener at 120V 60 Hz to avoid malfunction and damage Tools needed During assembly installation and adjustment of the opener instructions will call for hand tools as illustrated below Hack Saw Tn Wire Cutters Claw Hammer Adjustable End Wrench nee Pliers Screwdriver Planning Identify the type and height of your garage door Survey your garage area to see if any of the conditions below apply to your installation Additional materials may be required You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener SECTIONAL DOOR INSTA
111. r and or transmitter are prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards FOR HOME OR OFFICE USE Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation HAVING A PROBLEM 1 My door will not close and the light bulbs blink on my motor unit The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction e Verify the safety sensors are properly installed aligned and free of any obstructions Refer to Installation Step 10 Install The Protector SE System e Check diagnostic LED for flashes on the motor unit then refer to the Diagnostic Chart on the following page 2 My remotes will not activate the door e Verify your Premium door control is not blinking at If it is blinking deactivate the Lock Mode following the instructions for Using the dE Saen Senor Easter ete Multi Function Door Control Amber Indicator Light Green Indicator Lich a e Reprogram remotes following the programming instructions Refer to Programming e If remote will still not activate your door check diagnostic LED for flashes on motor u
112. r hand held remote control The door will open and close when you press the large push button Below are instructions for programming your opener to operate with additional Security remote controls To Add and Reprogram an Additional Hand held Remote Control USING THE MULTI FUNCTION DOOR CONTROL USING THE LEARN BUTTON 1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held AY remote that you wish to operate your garage door 3 Release the button when the y motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard To Erase All Codes From Motor Unit Memory To deactivate any unwanted remote first erase all codes Press and hold the learn button on motor unit until the learn indicator light goes out approximately 6 seconds All previous codes are now erased Reprogram each remote or keyless entry you wish to use Press and hold the button on the hand held remote that you wish to operate your garage door 2 While holding the remote button press and hold the LIGHT
113. r original pour la vie du produit Mod le 3110C Le moteur est garantit ne pas comporter de d fauts au niveau des mat riaux et ou de sa construction pendant une p riode de 24 mois complets 2 ans partir de la date d achat DEEE EEE EEE EEE EE EEE EEE AE EE EEE EEE EEE EEE AE EEE EEE EEE EE EEE eel 2006 The Chamberlain Group Inc Tous droits r serv s CRETE EEE EEE EE EE EEE EEE TE EEE ele el EEE EE EE EEE 114A3182B
114. rail de l ouvre porte de garage sur un 2 x 4 plac sur la Suivre les instructions qui se rapportent la porte de section sup rieure de la porte garage particuli re en se rapportant aux illustrations PORTE ARTICUL E OU PORTE RIGIDE AVEC GUIDES Un 2 x 4 pos plat convient tr s bien pour obtenir l espace qu il faut entre la porte et le rail e Lever l ouvre porte et le faire reposer sur un escabeau Si l escabeau n est pas assez haut demander de l aide e Ouvrir compl tement la porte et mettre un 2 x 4 plat sur sa partie sup rieure sous le rail e Si le panneau ou la section du dessus vient en contact DE ap avec le chariot lorsqu on l ve la porte tirer sur la I X biellette de d gagement du chariot pour d gager le fe Le 2x4 est utilis pour d terminer chariot int rieur du chariot ext rieur Faire glisser le Porte la hauteur de fixation correcte chariot ext rieur vers le moteur Il ne sera pas partir du plafond n cessaire de r assembler le chariot avant la fin de l op ration 13 Biellette de d gagement du chariot ENGAGE DEGAGE PORTE RIGIDE SANS GUIDES Poser un 2 x 4 sur le c t pour obtenir l espace qu il faut cee entre la porte et le rail e Enlever l emballage en mousse e Lever l ouvre porte et le faire r
115. rte m murale Porte d acc s FR T eee Porte O d acc s O pA D tecteur inverseur ra ne de s curit L espace entre le plancher eee A l et le bas de la porte ne doit a N vele dent D tecteur inverseur D tecteur inverseur as d passer 1 4 po 6 mm espace entre le plancher de s curit de s curit Pp P P i a D tecteur inverseur et le bas de la porte ne doit de s curit pas d passer 1 4 po 6 mm Inventaire de la bo te d emballage Votre ouvre porte de garage est emball dans deux bo tes mat riel d emballage Les pi ces peuvent tre coinc es qui contiennent le moteur et toutes les pi ces illustr es ci dans la mousse Les ferrures de montage sont galement apr s Les accessoires d pendront du mod le achet S il indiqu es ci apr s manque quoi que ce soit v rifier soigneusement le Model 3220C Model 3110C Model 3220C 1 Model 3110C 1 4 SECURITY SECURITY Agrafe de T l commande trois boutones T l commande une seule bouton pare soleil de t l commande Panneau de commande de porte multifonction Bouton de contr le de porte illumin Support de linteau Fil de sonnerie blanc et blanc rouge 2 conducteurs Moteur avec un diffuseurs Biellette courb e Coupleur de pignon Chariot Support de la porte e9 6 8 6 6 6 6 6 6 6 Documentation et tiquettes 2 Capteurs d inversion de s curit de s curit Biellette 1 il de transmission et
116. s autotaraudeuses 6AB x 1 1 2 po Commande de porte multifonctions Retirer le couvercle blanc en soulevant doucement la fente dans la partie sup rieure du couvercle l aide d un petit tournevis t te plate Fixer l aide de vis autotaraudeuses 6AB x 1 1 4 po installation standard ou de vis m taux 6 32 x 1 po dans la bo te simple comme suit e Percer et poser la vis inf rieure en laissant 1 8 po 3 mm faire saillie du mur e Placer le bas de la commande de porte par dessus la t te de vis et ajuster pour un ajustement serr e Percer et poser la vis sup rieure soigneusement afin d viter de fissurer le bo tier en plastique Ne pas serrer excessivement e Remettre le couvercle en place en ins rant les languettes inf rieures et en enclenchant en place REMARQUE Le gros bouton poussoir peut rester coinc si la commande de porte n est pas mont e sur une surface lisse Si aucun clic ne se fait entendre en appuyant sur le gros bouton poussoir desserrer les deux vis de montage ou d placer la commande de porte une surface plus lisse 3 Installation standard seulement Faire monter le fil de sonnerie le long du mur et du plafond jusqu au moteur Utiliser des agrafes isol es pour fixer le fil a plusieurs endroits Ne pas percer le fil avec une agrafe ce qui cr erait un court circuit ou un circuit ouvert Si votre porte d acc s est situ e a proximit de la porte de garage il est possible de
117. s curit 2 41B4494 1 Fil de sonnerie blanc et blanc rouge a 2 conducteurs 178B35 Biellette courb e NON ILLUSTRES 41A4675 7 Sachet des fixations de pose comprend les fixations a la page 3 114A3182 Manuel d instructions es eg 8g 5 gees Pi ces d assemblage du moteur 31D477 41B4245 30B363 12A373 41A3150 41D4671 12D630 2 41A5388 144B41 144B42 20B17 158A69 41C556 41A5394 81B170 1 D SIGNATION Couvercle d axe de transmission Cord lectrique Condensateur 1 2 HP Support de condensateur Bornier avec vis Unit d interrupteur de limite Support douille d ampoule interrupteur limiteur Ensemble d entra nement moteur comprenant Poulie 22 dents Poulie 28 dents Courroie d entra nement Bagues de retenue Entretoises de support s parateur Ens de support socle monteur Vis sans fin limiteuse d arbre Contact INTERRUPTEUR DE FIN Fe fermeture DE COURSE run Pignon menant Contact de fin Contact de course central d ouverture D SIGNATION 41C4672 N cessaire tr min entra nement filet 41A4837 1 Vis sans fin et fixation 41C5417 Harnais de c bles basse tension 41C5416 Harnais de c bles haute tension 41AS050 1 Carte logique du r cepteur 41A5490 5 Couvercle Mod le 3110C 41A5490 6 Mod le 3220C 41C22 1 Moyeu d accouplement d entra nement 175C147 Douille d ampoule 108D78 Diffuseur 41A5387 Chassis avec support de rail 12B654
118. saires de renforts de porte pr voient la fixation directe de l axe de chape et de la biellette de porte Le support de porte est alors inutile proc der l tape 13 PORTES ARTICUL ES 1 Centrer le support de la porte avec l axe vertical pr c demment trac et utilis pour la pose du support de linteau Il convient de noter le positionnement correct de UP vers le haut comme estampill l int rieur du support 2 Positionner le bord sup rieur du support de 2 4 pouces 5 10 cm plus bas que le bord sup rieur de la porte O directement sous toute solive travers le haut de la porte 3 Marquer percer des trous et poser comme indiqu ci apr s selon la construction de votre porte Portes m talliques ou l g res utilisant une ferrure angulaire verticale entre le support du panneau de porte et le support de porte e Percer des trous de fixation de 3 16 po Fixer le support de porte l aide des deux vis autotaraudeuses de 1 4 po 14 x 5 8 po Figure 2A e On peut galement utiliser deux boulons de 5 16 po des rondelles de blocage et des crous non fournis Figure 2B Portes m talliques isol es ou l g res renforc es l usine e Percer des trous de fixation de 3 16 po Fixer le support de porte l aide des vis autotaraudeuses Figure 3 Portes en bois e Utiliser les trous sup rieurs et inf rieurs ou lat raux de support de porte Percer des trous de 5 16 po
119. sceau d tecteur soit branch et correctement align Consulter l tape 11 la page 18 16 A AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite d lectrocution e S assurer que le courant est coup AVANT de poser la commande de porte e Raccorder UNIQUEMENT des fils basse tension 24 V Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite d une porte de garage qui se ferme e Poser la commande de porte en vue de la porte de garage hors de la port e des enfants une hauteur minimum de 5 pieds 1 5 m et l cart de toutes les pi ces mobiles de la porte e Ne JAMAIS laisser des enfants faire fonctionner les boutons poussoirs de la commande de porte ou les metteurs de la t l commande ni jouer avec ceux ci e Actionner la porte UNIQUEMENT lorsqu on la voit clairement qu elle est bien r gl e et que rien ne g ne la course de la porte e TOUJOURS garder la porte de garage en vue jusqu ce qu elle soit compl tement ferm e Ne JAMAIS laisser personne croiser le chemin d une porte de garage qui se ferme GRANDEUR R ELLE DES FIXATIONS 5 DEAE Bouton poussoir clair de la Chevill commande de porte Vis 6AB x 1 1 2 po 1EVII8S pour murs secs NN Panneau commande de porte Multifonction pr c bl es installation standard Vis 6 32 x 1 po Vis 6AB x 1 1 4 po Agrafe isol e INSTALLATION n INSTALLATION Figure 1 STANDARD
120. self threading screws Figure 2A e Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insulated or light weight factory reinforced doors e Drill 3 16 fastening holes Secure the door bracket using the self threading screws Figure 3 Wood Doors e Use top and bottom or side to side door bracket holes Drill 5 16 holes through the door and secure bracket with 5 16 x2 carriage bolts lock washers and nuts not provided Figure 4 NOTE The 1 4 14x5 8 self threading screws are not intended for use on wood doors g ACTUAL SIZE Self Threading Screw 1 4 14x5 8 To prevent damage to garage door reinforce inside of door with angle iron both vertically and horizontally Header Bracket Bracket Location HORIZONTAL AND VERTICAL REINFORCEMENT IS NEEDED Vertical FOR LIGHTWEIGHT GARAGE Centerline DOORS FIBERGLASS of Garage ALUMINUM STEEL DOORS Door WITH GLASS PANEL ETC NOT PROVIDED Figure 1 Vertical Not Provided Reinforcement Vertical Vertical Reinforcement Centerline of Garage Door Vertical Centerline O of Garage Door 0 f Bracket o s cP Lock Washer Door po 5 1 i Bracket r Nut 5 16 18 Self Threading Screw 1 4 14x5 8 Figure 2B Figure 2A Inside Edge of Door or Reinforcement Board Not Provided N 5 16 x2 Vertical
121. sh button to close the door The door will not move more than an inch 2 5 cm and the opener lights will flash The garage door opener will not close from a remote if the indicator light in either sensor is off alerting you to the fact that the sensor is misaligned or obstructed If the opener closes the door when the safety reversing sensor is obstructed and the sensors are no more than 6 15 cm above the floor call for a trained door systems technician 25 WARNING Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door e Safety reversal system MUST be tested every month e If one control force or travel limits is adjusted the other control may also need adjustment e After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 3 8 cm high object or 2x4 laid flat on the floor 1 1 2 3 8 cm board or a 2x4 laid flat WARNING Without a properly installed safety reversing sensor persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door A A A v v v A 0 G Q A A V V V lel I net TT mens 2 S
122. sont tous sous Niveau de ia une tension EXTREME 0 menuisier e TOUJOURS appeler un technicien form en syst mes de FE porte si la porte de garage force ou est d s quilibr e Une porte de garage d s quilibr e peut ne pas remonter au besoin WE gt al Les m thodes de pose varient en fonction de la porte du garage Suivre les instructions qui correspondent a la porte TS du garage sur laquelle on pose l ouvre porte A 1 Fermer la porte et marquer l axe vertical int rieur de la porte du garage 2 Prolonger cet axe sur le linteau au dessus de la porte Ne pas oublier que l on peut fixer le support du linteau moins de 4 pieds 1 22 m droite ou i 3 po 7 5 cm Guide gauche de l axe de la porte seulement si un ressort aa T PON de torsion ou une plaque d appui centrale g ne ce e support peut galement tre fix au plafond se Linteau HN Point de course reporter la page 9 si le d gagement n est pas RONA suffisant Il peut tre mont l envers sur un mur Ly au besoin pour gagner environ 1 2 po 1 cm Porte Si l on doit poser le support de linteau sur un 2 x 4 au Ly mur ou au plafond utiliser des tire fond non fournis pour s assurer que le 2 x 4 est bien retenu sur les solives comme montr sur cette page et la page 8 3 Ouvrir la porte son po
123. st be connected and aligned correctly before the garage door opener will move in the down direction IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR When properly connected and aligned the sensor will detect an obstacle in the path of its electronic beam The sending eye with an amber indicator light transmits an invisible light beam to the receiving eye with a green indicator light If an obstruction breaks the light beam while the door is closing the door will stop and reverse to full open position and the opener lights will flash 10 times The units must be installed inside the garage so that the sending and receiving eyes face each other across the door no more than 6 15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware WARNING e Be sure power is not connected to the garage door opener BEFORE installing the safety reversing sensor e To prevent SERIOUS INJURY or DEATH from a closing garage door Correctly connect and align the safety reversing sensor This required safety device MUST NOT be disabled Install the safety reversing sensor so beam is NO HIGHER than 6 15 cm above garage floor If it is necessary to mount the units on the wall the brackets must be securely fastened to
124. st hors tension Poser et aligner les supports de mani re a ce que les d tecteurs se fassent face l un l autre de part et d autre de la porte du garage le faisceau n tant pas une hauteur de plus de 6 po 15 cm au dessus du sol Ils peuvent tre pos s de trois fa ons suivant vos exigences comme suit Pose aux guides de la porte de garage mode pr f rable e Faire glisser les bras courb s par dessus le bord arrondi de chaque guide de porte les bras courb s tant dirig s vers la porte Enclencher en place contre le c t du guide II doit reposer a plat avec le rebord embrassant le bord arri re du guide comme illustr la Figure 1 Si votre guide de porte ne supporte pas solidement le support une pose murale est recommand e Pose murale Figure 2 et 3 e Placer le support contre le mur les bras courb s tant dirig s vers la porte S assurer qu il y a un d gagement suffisant et qu aucun obstacle n est dans le parcours du faisceau du d tecteur Si une profondeur suppl mentaire est n cessaire on peut employer un support de rallonge Se reporter a la section accessoires ou des blocs en bois Utiliser les trous de montage de support comme gabarits pour positionner et percer deux avant trous de 3 16 de po de diam tre sur le mur de chaque c t de la porte une hauteur ne d passant pas 6 po 15 cm au dessus du sol e Fixer les supports au mur l aide de tire fond Non fo
125. stallation Step 13 is completed o o g 3 8 8 Trolley KO 8 og Release Arm ENGAGED RELEASED le ONE PIECE DOOR WITHOUT TRACK Header A 2x4 on its side is convenient for setting an ideal door to rail distance e Remove foam packaging e Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough e Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail e The top of the door should be level with the top of the motor unit Do not position the opener more than 4 10 cm above this point 2x4 is used to determine the correct mounting height from ceiling INSTALLATION STEP 6 Hang the Opener Three representative installations are shown Yours may be different Hanging brackets should be angled Figure 1 to provide rigid support On finished ceilings Figure 2 attach a sturdy metal bracket to structural supports before installing the opener This bracket and fastening hardware are not provided Existing brackets from a previous installation may be fastened to the sides of the motor unit as in Figures 1 and 2 or to the mounting tabs as shown in Figure 3 Then continue with step 5 below 1 Remove foam packaging Measure the distance
126. t me d inversion de s curit bien install des personnes plus particuli rement les petits enfants pourraient tre GRIEVEMENT BLESSEES ou TUEES par une porte de garage qui se referme e Une trop grande force sur la porte de garage g nera un fonctionnement appropri du syst me d inversion de s curit e Ne JAMAIS augmenter la force au del du niveau n cessaire la fermeture de la porte e Ne JAMAIS utiliser les r glages de force pour compenser une porte qui force ou qui adh re e Apr s avoir r gl une commande force ou course il peut tre n cessaire de r gler l autre commande e Apr s avoir effectu quelque r glage que ce soit on DOIT faire l essai du syst me d inversion de s curit La porte de garage DOIT remonter au contact d un objet d une hauteur de 1 1 2 po 3 8 cm ou un 2 x 4 pos plat sur le sol Vis de r glage de la force Panneau arri re Force D overture Force De Fermeture REGLAGES 3 OPERATION AVERTISSEMENT Essai du syst me d inversion de Sans un syst me d inversion de s curit bien install des s curit personnes plus particuli rement les petits enfants pourraient tre GRIEVEMENT BLESSEES ou TUEES par une porte de ESSAI garage qui se referme e On DOIT proc der a une v rification mensuelle du syst me e Laporte tant enti rement ouverte placer une planche de 1 1 2 po 3 8 cm d paisseur ou un 2 x
127. t mais s ouvre d au moins 5 pieds 1 5 m Augmenter la course d ouverture en tournant la vis de r glage UP droite Un tour complet de la vis correspond 2 po 5 cm de course REMARQUE Pour emp cher le chariot de frapper le boulon de protection du couvercle garder une distance minimale de 2 po 4 po 5 10 m entre le chariot et le boulon e Si la porte ne s ouvre pas d au moins 5 pieds 1 5 m R gler la force d ouverture UP comme indiqu dans la 2 op ration des r glages e Si la porte ne se ferme pas compl tement Augmenter la course de fermeture en tournant la vis de r glage DOWN dans le sens antihoraire Un tour complet de la vis correspond 2 po 5 cm de course Si la porte ne se ferme toujours pas compl tement et que le chariot heurte le support de la poulie page 4 essayer de rallonger le bras de la porte page 21 et de diminuer la course de fermeture e Si l ouvre porte fait remonter la porte lorsqu elle est compl tement ferm e Diminuer la course de fermeture Tourner la vis de r glage de fermeture DOWN dans le sens horaire Un tour complet de la vis correspond 2 po 5 cm de course 23 AVERTISSEMENT Sans un syst me d inversion de s curit bien install des personnes plus particuli rement les petits enfants pourraient tre GRIEVEMENT BLESSEES ou TUEES par une porte de garage qui se referme e Un r glage erron des courses de la
128. t que le faisceau lumineux sera interrompu Le d tecteur n a aucun effet lors du cycle d ouverture Si le d tecteur n est pas install ou est mal align la porte ne se fermera pas partir d une t l commande main Cependant vous pouvez fermer la porte avec la commande de porte a cl de verrouillage ext rieur ou l entr e sans cl si vous les activez jusqu ce que la fermeture soit compl te Si vous les rel chez trop t t la porte s inversera L clairage de l ouvre porte de garage s allumera dans les cas suivants lorsque l on branche l ouvre porte de garage pour la premi re fois sur le courant lorsque le courant est interrompu lorsque l ouvre porte est actionn Cet clairage s teint automatiquement apr s 4 1 2 minutes ou il assure un clairage constant lorsqu on actionne la fonction d clairage sur la commande de porte a functions multiples Des ampoules de 100 watts maximum doivent tre utilis es clairage Security Les lumi res s allumeront galement lorsqu une personne franchira la porte de garage ouverte Sur une commande murale de luxe cette fonction d clairage peut tre d sactiv e de la fa on suivante les lumi res ferm es enfoncer et tenir le bouton d clairage pendant 10 secondes jusqu ce que les lumi res s teignent puis s allument de nouveau Pour r tablir cette fonction commencer avec le dispositif d clairage de l ouvre porte allum
129. t slipping e Thread the other end of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Secure with an overhand knot NOTE If it is necessary to cut the rope heat seal the cut end with a match or lighter to prevent unraveling CAUTION To prevent possible OVERHEATING of the endpanel or light socket e DO NOT use short neck or specialty light bulbs e DO NOT use halogen bulbs Use ONLY incandescent Top Lens Tab Bottom Chassis Slots Bottom Insert Bottom Chassis Slot Lens Tabs First WARNING To prevent possible SERIOUS INJURY or DEATH from a falling garage door e f possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly e NEVER use emergency release handle unless garage doorway is clear of persons and obstructions e NEVER use handle to pull door open or closed If rope knot becomes untied you could fall o o 2 QJ Trolley CES Release Arm NOT Overhand Emergency Knot Release Handle INSTALLATION STEP 10 Electrical Requirements To avoid installation difficulties do not run the opener at this time To reduce the risk of electric shock your garage door opener has a grounding type plug with a third gro
130. til it receives the sender s beam When the green indicator light glows steadily tighten the wing nut WARNING To prevent possible SERIOUS INJURY or DEATH from electrocution or fire e Be sure power is not connected to the opener and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection e Garage door installation and wiring MUST be in compliance with all local electrical and building codes e NEVER use an extension cord 2 wire adapter or change plug in any way to make it fit outlet Be sure the opener is grounded PERMANENT WIRING CONNECTION Ground Tab Green Ground Screw Ground Wire White Wire Black Wire TROUBLESHOOTING THE SAFETY SENSORS 1 If the sending eye indicator light does not glow steadily after installation check for e Electric power to the opener e A short in the white or white black wires These can occur at staples or at opener connections e Incorrect wiring between sensors and opener e A broken wire 2 If the sending eye indicator light glows steadily but the receiving eye indicator light doesn t e Check alignment e Check for an open wire to the receiving eye 3 If the receiving eye indicator light is dim realign either sensor NOTE When the invisible beam path is obstructed or misaligned while the door is closing the door will reverse If the door is already open it will not close The opener lights will blink 10 times If bu
131. travers la porte et fixer le support l aide de boulons t te bomb e et collet carr de 5 16 po x 2 po des rondelles de blocage et des crous non fournis Figure 4 REMARQUE Les vis autotaraudeuses de 1 4 po 14 x 5 8 po ne sont pas pr vues pour tre utilis es sur des portes en bois GRANDEUR R ELLE DES FIXATIONS Vis autotaraudeuse 1 4 po 14 x 5 8 po 19 ATTENTION Pour pr venir les dommages la porte de garage renforcer l int rieur de la porte par une ferrure angulaire tant verticalement qu horizontalement Situation du support DES RENFORTS HORIZONTAUX ET VERTICAUX SONT REQUIS DANS LE CAS D UNE PORTE DE GARAGE L G RE EN FIBRE DE VERRE EN ALUMINIUM EN ACIER EN PANNEAUX DE VERRE ETC NON FOURNIS Ligne du centre vertical de la porte de garaje Figure 1 Renforts verticaux Non fournis O Ligne du centre vertical Renforts a porte de garaje verticaux Boulon 5 16 po 18 x 2 po Ligne du centre vertical de la porte de garaje Support de la porte Rondelle de blocage de 5 16 po i crou de de la porte 5 16 po 18 Vis autotaraudeuse 1 4 po 14 x 5 8 po Figure 2B Figure 2A Non fournis Bord int rieur de la porte ou morceau de bois de renfort Boulon 5 16 po x 2 po Ligne du centre r vertical de la porte de garaje Ligne du centre vertical de la porte de garaje PS Vis
132. un maximum de quatre clignotements pour 4 1 2 minutes l ment de verrouillage L l ment de verrouillage est con u de mani re emp cher le fonctionnement de la porte l aide de t l commandes main Cependant la porte s ouvrira et se fermera partir de la commande de porte de la serrure ext rieure ou du syst me d ouverture sans cl en accessoire Pour actionner appuyer sur le bouton de verrouillage et le tenir pendant 2 secondes L clairage de la barre poussoir clignotera aussi longtemps que l l ment de verrouillage sera en marche Pour arr ter appuyer nouveau sur le bouton de verrouillage et le tenir pendant 2 secondes L clairage de la barre poussoir cessera de clignoter L l ment de verrouillage sera galement neutralis chaque fois que le bouton LEARN se trouvant sur le panneau de l ouvre porte sera actionn Fonctions suppl mentaires lors de l utilisation avec la t l commande trois boutons A Commande de l clairage de l ouvre porte Vous pouvez programmer la t l commande de mani re commander non seulement la porte mais aussi l clairage 1 La porte tant ferm e enfoncer et tenir un petit bouton de la t l commande auquel on attribuera le contr le de l clairage 2 Continuer tenir tout en enfongant le bouton d clairage sur le panneau de commande de la porte 3 Continuer tenir les deux boutons tout en enfon ant le bouton de blocage de la commande d
133. unding pin This plug will only fit into a grounding type outlet If the plug doesn t fit into the outlet you have contact a qualified electrician to install the proper outlet If permanent wiring is required by your local code refer to the following procedure To make a permanent connection through the 7 8 hole in the top of the motor unit Remove the motor unit cover screws and set the cover aside Remove the attached 3 prong cord Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded e Reinstall the cover To avoid installation difficulties do not run the opener until Step 11 below INSTALLATION STEP 11 Complete Safety Reversing Sensor Installation ALIGNING THE SAFETY SENSORS Plug in the opener The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction If the green indicator light in the receiving eye is off dim or flickering and the invisible light beam path is not obstructed alignment is required e Loosen the sending eye wing nut and readjust aiming directly at the receiving eye Lock in place e Loosen the receiving eye wing nut and adjust the sensor vertically and or horizontally un
134. urnis e Si des supports de rallonge ou des blocs en bois sont employ s ajuster les ensembles droit et gauche a la m me distance vers l ext rieur depuis la surface de montage S assurer qu il n y a aucun obstacle de ferrure de porte Pose au sol Figure 4 e Utiliser des blocs en bois ou des supports de rallonge Se reporter a la section Accessoires pour lever les supports de d tecteur de mani re a ce que les diffuseurs ne soient pas a plus de 6 po 15 cm au dessus du sol e Mesurer soigneusement et placer les ensembles droit et gauche la m me distance vers l ext rieur depuis le mur S assurer qu il n y a aucune obstruction de ferrure de porte e Fixer au sol a l aide des ancrages de b ton comme illustr 12 Figure 1 MONTAGE SUR GUIDES DE PORTE C T DROIT Guide de porte i Rebord T moin lumineux MONTAGE MURAL C T DROIT Attachez le morceau de bois au mur avec des tire fond Non fournis Figure 2 T moin lumineux Support de d tecteur __ Non fournis Diffuseur ag Figure 3 MONTAGE MURAL C T DROIT Support de rallonge l Voir Accessoires Fournis avec support de rallonge Tr Tr te mo Support de Fournis avec support d tecteur de rallonge Diffuseur lumineux Figure 4 MONTAGE AU SOL C T DROIT Fixer l aide d ancrages de b ton Non Fournis 1 1 ur D5
135. uverture de la porte diminuer la course d ouverture Tourner la vis de r glage d ouverture UP de 4 tours en sens antihoraire Appuyer sur le gros bouton poussoir de la commande de porte Le chariot se d placera jusqu la position enti rement ouverte la main ouvrir compl tement la porte parall le au plancher puis soulever la biellette jusqu au chariot La biellette doit toucher le chariot juste derri re son trou de raccordement Se reporter Chariot enti rement ouvert positions de la biellette dans l illustration Si la biellette est trop courte diminuer la course d ouverture Un tour complet de la vis de r glage correspond a 2 pouces 5 cm de course e R glage de la fermeture de la porte diminuer la course de fermeture Tourner la vis de r glage de fermeture DOWN de 4 tours complets en sens horaire Appuyer sur le bouton poussoir de la commande de porte Le chariot se d placera la position de porte compl tement ferm e Chariot compl tement ferm Figure 5 Chariot int rieur Trou de raccordement la main fermer compl tement la porte puis soulever la biellette jusqu au chariot La biellette doit toucher le chariot juste devant son trou de raccordement Se reporter Chariot compl tement ferm positions de la biellette dans l illustration Si la biellette arrive plus loin que le trou de raccordement raccourcir la course
136. uvre porte de garage REMARQUE Utiliser uniquement une ampoule standard L utilisation d une ampoule col court ou d une ampoule sp cialis e peut causer une surchauffe du panneau d extr mit ou de la douille POSE 9 OP RATION Pose de la corde et de la poign e de d clenchement d urgence e Faire passer une extr mit de la corde dans le trou sup rieur de la poign e rouge de fa on que le mot NOTICE puisse tre lu l endroit Fixer l aide d un n ud simple au moins 1 po 2 5 cm de l extr mit de la corde pour emp cher le glissement e Passer l autre extr mit de la corde dans le trou du levier de d clenchement du chariot ext rieur e Ajuster la longueur de la corde de fa on que la poign e soit environ 6 pieds 1 83 m du sol Fixer la corde l aide d un n ud simple REMARQUE Si la corde doit tre coup e br ler l g rement l extr mit coup e pour emp cher qu elle ne s effiloche ATTENTION Pour viter toute SURCHAUFFE ventuelle du panneau d clairage e NE PAS utiliser d ampoules col court ou de forme sp ciale e NE PAS utiliser d ampoules halog ne Utiliser UNIQUEMENT des ampoules incandescentes Languette sup rieure du diffuseur Diffuseur lt du diffuseur Fente sup rieure de chassis Fentes inf rieures de chasis Languette sup rieure du diffuseur O O 0 0 O OOO Fente sup rieure de ch ssis
137. vel One piece door without track pivot hardware INSTALLATION STEP 2 Install the Header Bracket Wall Mounting Holes You can attach the header bracket either to the wall above the garage door or to the ceiling Follow the instructions which will work best for your particular requirements Do not install the header bracket over drywall If installing into masonry use concrete anchors not provided WALL HEADER BRACKET INSTALLATION e Center the bracket on the vertical centerline with the bottom edge of the bracket on the horizontal line as shown with the arrow pointing toward the The nail hole is for positioning only You must use lag screws to mount the header bracket Optional Vv Wall Mounting Holes Vertical Centerline of Garage Door ceiling re eader e Mark the vertical set of bracket holes do not use Wall gt Ka Erg PTS a the holes designated for ceiling mount Drill 3 16 a nee Ko r pilot holes and fasten the bracket securely to a Structural Bracket structural support with the hardware provided Support AF Door Spring Horizontal 1 HARDWARE SHOWN ACTUAL SIZE Line N 2 ee g l Garage Door Highest Point of Vertical Lag Screw Garage Door Travel Centerline of Garage Door 5 16 9 x 1 5 8 CEILING HEADER BRACKET INSTALLATION e Extend the vertical centerline onto the ceiling as shown Center the bracket on the vertical
138. ymptom Sending indicator light glows steadily receiving indicator light is dim or flashing Safety Sensors e Realign receiving eye sensor clean lens and secure brackets slightly misaligned dim or flashing LED e Verify door track is firmly secured to wall and does not move Symptom Motor has over heated the motor unit does not operate 5 FLASHES RPM Sensor Short travel 6 8 15 20 cm Motor overheated or e Unplug unit to reset Try to operate motor unit check diagnostic code possible RPM sensor e If it is still flashing 5 times and motor unit moves 6 8 15 20 cm replace RPM failure Unplug to reset sensor e If motor unit doesn t operate motor unit is overheated Wait 30 minutes and retry If motor unit still will not operate replace logic board 6 FLASHES Sun na Symptom Motor unit doesn t operate Motor Circuit Failure e Replace logic board because motor rarely fails Replace Receiver Logic Board PROGRAMMING NOTICE If this Security garage door opener is operated with a non rolling code transmitter the technical measure in the receiver of the garage door opener which provides security against code theft devices will be circumvented The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non rolling code transmitter to circumvent that technical measure Your garage door opener has already been programmed at the factory to operate with you