Home

Caldera GT305 User's Manual

image

Contents

1. The gastop you have purchased uses either LP or natural gas It cannot be converted from one to the other The proper fuel must be used 3 Use only a 120 volt grounded outlet Installation must conform to local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 and CAN CSA C22 1 Canadian Electrical Code Part All gastops must be grounded for the controls to function properly Improper installation could destroy your electronic controls and void the warranty 4 Do not use an extension cord 5 Always unplug the unit before servicing 6 Know where your gas shut off valve is and how to operate it 7 Be sure all packing materials have been removed including any tape on the surface or underside of the unit 8 Do not repair or replace any part of the unit unless specifically recommended in the Installation or Use and Care manual All other servicing should be performed by a qualified technician Safety Precautions A 1 Use the unit only for its intended purpose 2 For safety reasons never use the unit to heat or warm the room 3 When using an electrical appliance near the gastop be sure that the cord of the appliance does not come into contact with the burner area 4 Do not leave children unattended in an area where appliances are in use Teach them not to touch the gastop 5 NOONE should ever be allowed to sit or stand on any part of the gastop or the area around the gastop Phone 800 72
2. Not Cook on a Broken Gastop If the cook top should break cleaning solutions and spillovers may penetrate the broken cook top and create a risk of electric shock Contact a qualified technician immediately Keep any venting filters clean to avoid grease fires and maintain good venting 22 Do not store or use gasoline kerosene or other flammable vapors and liquids in the vicinity of this appliance A 23 IMPORTANT Verify that meat and poultry has been cooked to an internal temperature of 160 degrees Fahrenheit for meat and 180 degrees Fahrenheit for poultry to protect against food borne illnesses 24 Avoid scratching your ceramic glass Rings other jewelry and sharp metal objects may scratch your gastop 25 Do not operate without the burner cap and grates in place 26 Do not use the gastop as a cutting board 27 Be sure controls are off and burners and grates are cool before attempting to remove 28 Keep wood and plastic items away from the vicinity of the gastop to avoid fire or melting 29 Keep canned and sealed goods away from the heat as the contents may expand and explode Phone 800 725 7711 www calderacorp com Fax 800 962 3072 7 Safety Features Intentional Touch When no burners are activated touching multiple keys at the same time will not initiate any functions This prevents un intentional or accidental use by children or pets When a burner is on a multiple key touch that includes the off key shut the burner
3. 5 7711 www calderacorp com Fax 800 962 3072 5 Do not store items of interest to children above or at the back of the gastop Everyone should use caution when reaching over the gastop as they could be seriously injured or burned 6 7 A 10 11 12 13 14 15 16 Do not store items on the unit Never let clothing potholders or other flammable materials come into contact with or close proximity to the burners while in operation Flammable fabric drapes or wall coverings must be kept away from the gastop as they may ignite and cause personal injury For personal safety wear proper apparel loose fitting or hanging garments should never be worn while cooking Allow sufficient time for the unit to cool before touching or exposing surface areas to flammable materials Always use dry potholders when removing utensils from the burners Wet or damp potholders can cause steam burns Do not let potholders touch the burners or grate Do not use a towel or bulky cloth in place of a potholder WARNING Clean the gastop with caution A wet sponge or cloth used to wipe spills on a hot cooking surface can result in steam burns and may damage the surface of the gastop Some cleansers can produce noxious fumes if applied to a hot surface Be sure all controls are turned off and the gastop is cool before using aerosol cleaners The chemicals used in aerosol sprays may be flammable Do not let cooking grease or other flammable materia
4. C A L D E R A yr The Touch Series Use and Care Manual For models SST365 SST305 GT365 GT305 WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s home Follow your gas supplier s instructions If you cannot reach your gas supplier call the fire department INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER Installer Please leave these instructions with the consumer for future reference Phone 800 725 7711 www calderacorp com Fax 800 962 3072 CONGRATULATIONS The Caldera Touch Series touch control gastops have been engineered to be simple to use while providing many extra features that benefit your cooking and your cooking experience We hope you enjoy your purchase REGISTRATION We encourage you to register your gastop so you may take advantage of our full two year warranty and limited five year warranty should the need ever arise Registration may be done on our website at www calderacorp com by returning the enclosed postcard or
5. by faxing us toll free at 800 962 3072 For your convenience the model number serial number and manufacturers numbers are below Phone 800 725 7711 www calderacorp com Fax 800 962 3072 2 Table of Contents Page 4 7 Safety Precautions Page 8 10 Operating Instructions Page 11 Warranty and Service Information Phone 800 725 7711 www calderacorp com Fax 800 962 3072 3 IMPORTANT Read all instructions before using your gastop unit If you have questions please call us at 800 725 7711 between 9am and 5pm EST Electrical Requirements Your gastop must be connected to a properly grounded 120 volt AC 60 Hz 15 amp electrical service and installed by a qualified installer It is the personal responsibility and obligation of the customer to contact a qualified electrician installer and have the unit connected to a properly grounded circuit in accordance with local codes of your area or if no codes apply the National Electric Code ANSI NFPA 70 Latest Edition must be followed Copies are available by writing National Fire Protection Association Battery March Park Quincy MA 02269 In Canada follow CAN CSA C 22 1 Canadian Electrical Code Part 1 Copies are available by writing CSA 178 Rexdale Boulevard Toronto Ontario CANADA M9W IR3 Important Safety Instructions As with all appliances there are certain rules to follow for safe operation Make sure everyone who operates this gastop is familiar with the operation and wit
6. h the following precautions It is the personal responsibility and obligation of the customer to contract a qualified installer and have the unit connected properly in accordance with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 Latest Edition and CAN CSA B149 1 Natural Gas and Propane Installation Code The gastop must be connected to the proper gas supply and checked for leaks Using Gas Safely Gas fuels and their uses can cause minor exposure to benzene formaldehyde carbon monoxide and soot primarily from incomplete combustion Significant exposure to these substances can cause cancer or reproductive harm Properly adjusted burners with a blue rather than yellow flame will minimize the incomplete combustion Venting with a hood or open window will further minimize exposure The maximum gas supply pressure may not exceed 14 inches W C P 1 2 PSI Never use a match or other flame to locate a gas leak Explosion fire or injury could result Know where your main gas shut off valve is located Phone 800 725 7711 www calderacorp com Fax 800 962 3072 4 Before Using Your Gastop A READ THIS MANUAL 1 Insure proper installation and servicing Have the gastop installed by a qualified technician Installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 and CAN CSA B149 1 Natural Gas and Propane Installation Code 2
7. ls accumulate on or near the unit Never leave the unit unattended while cooking Very hot oils can cause fire Do not use water to extinguish grease fires Never pick up a flaming pan If possible turn the gastop off Then smother the flames use a tight fitting lid flat tray cookie sheet etc or use a dry chemical or foam type fire extinguisher Baking soda will also work but your kitchen should be equipped with a fire extinguisher Always heat fat slowly watching as it heats Stir combinations of fats together If high settings are used remain near the unit to monitor for flammable splattering grease and or boil overs WARNING Glass and Glazed Cooking Utensils Only certain types of glass glass ceramic earthenware or other glazed utensils are suitable for range top service without breaking due to the sudden change in temperature WARNING Utensil Handles Should Be Turned Inward and Not Extended Over Adjacent Surface Units To reduce the risk of burns ignition of flammable materials and spillage due to unintentional contact with the utensil the handle of a utensil should be positioned so that it is turned inward and does not extend over adjacent surface units Phone 800 725 7711 www calderacorp com Fax 800 962 3072 6 19 Use the proper pan size For safety reasons the burner flame should not extend beyond the cooking utensil 20 Before removing pots and pans be sure to turn the burner off A 21 WARNING Do
8. n the Warranty period or return of the enclosed registration card is required to obtain warranty service Service Information Should you need to have your Caldera gastop serviced please call us directly at 800 725 7711 between 9AM and 5PM EST A Caldera service representative will diagnose your problem and set up a service technician to handle your repair as quickly as possible It is important that you return your warranty card or register your Caldera gastop on line at www calderacorp com so that we may serve you more efficiently Phone 800 725 7711 www calderacorp com Fax 800 962 3072 11 Part SS 69 10 0 Revised 06 23 06 Phone 800 725 7711 www calderacorp com Fax 800 962 3072 12
9. nty For two years from the date of original purchase we will pay for parts and labor to repair or replace any part of your gastop that has failed due to a manufacturing defect Five Year Parts Warranty For an additional three years after the Full Two Year Warranty Caldera agrees to provide any parts necessary for the repair of your unit due to a manufacturing defect You will be responsible for the labor charges This warranty does not cover damage due to acts of God accident misuse abuse negligence commercial use or modification to any part of the product This warranty does not cover damage due to improper operation or maintenance connection to improper voltage supply or attempted repair by anyone other than an authorized Caldera repair service This warranty is valid only in the United States This warranty is invalid if the factory applied serial number has been altered or removed from the product REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER CALDERA CORPORATION SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY Proof of purchase in the form of a receipt or bill of sale which is evidence the specific unit is withi
10. o Lock Instant Off And Lock To instantly turn off all burners or to lock the controls the Lock key must be touched and held for 2 seconds then the LED beneath the Lock key will shut off all burners will turn off and the control will beep once to indicate that the unit is in Lock mode When Locked the keys cannot be activated and do not emit a beep if touched Automatic Locking And Deactivation The gastop will also lock automatically if no burners have been used for ten minutes This feature may be deactivated by touching the lock key and the front left ON OFF Key for 3 seconds while all burners are off Two beeps acknowledges deactivation one beep indicates reactivation To Unlock While in Lock mode to activate the gastop the Lock key must be touched and held for 2 seconds After a 1 5 second touch the control will beep once and the LED beneath the Lock key will turn On indicating that the burners can be programmed Phone 800 725 7711 www calderacorp com Fax 800 962 3072 9 Using A Burner Select a burner by touching its corresponding ON OFF key The ON OFF keys are arranged to mirror the burner locations The 8 segment LED will blink p for program Press the up or down arrow If the down arrow is touched the burner will come on at level 4 If the up arrow is pressed the burner will come on H high You may then move to the desired setting using the up and down arrow keys The programming mode blinking p lasts fo
11. off Automatic Lock Feature To operate the gastop it must first be unlocked by touching the lock key R for two seconds This is an added feature to protect against misuse If the gastop has not been used for a period of 10 minutes after all burners have been shut off the gastop will automatically re enter lock mode unless you have elected to disable this feature see next page One Touch Off Touching the lock key for one second will deactivate all burners This is useful if you have an emergency or if you need to leave the gastop for an unknown period of time to either answer the door the phone or tend to a child for example Operating instructions Lock Unlock touch the keyhole for 2 seconds The red light shows that the controls enabled The digit and dot indicate the 21 power l levels L L 1 2 1 1 1 2 2 2 1 2 etc C ALDERA H has no 32 increment Control layout follows the burner lay Front Left Rear Left etc O m T 4 SA TA pA IA A Touch the on off for the appropriate burner the digit will display P indicating programable mode Pressing the down arrow turns the burner on to level 4 Pressing the up arrow turns the burner on to high Then touch the up or down arrow to scan to the desired setting Phone 800 725 7711 www calderacorp com Fax 800 962 3072 8 Caldera has strived to bring you the ultimate in a gastop while maintaining a high degree of usability Please operate your unit sensibly and
12. r 10 seconds Selecting A Power Level A brief touch to the control arrows will adjust the power by 1 2 increments 21 settings This is indicated by a beep and circular LED to the right of the seven segment LED A steady touch will scan through the eleven whole number settings Settings L 1 thru 3 1 2 are the simmer settings your gas burner will cycle on and off for varying amounts of time depending on the setting All settings of 4 and above produce a steady flame Turning A Burner Off A brief touch to the appropriate burner s ON OFF key will turn the burner off You can turn all burners off at the same time by touching the lock icon for 1 1 2 seconds Power failure In case of a power failure your unit will not operate It will fail safe Each burner and the overall safety valve will shut the flow of gas of automatically Flame height and Appearance TTT TTN Yellow Flame call your Yellow tipped blue flame Soft blue flame normal gas company for service normal for L P for natural gas Grates And Burner Caps Grates and burner caps may be washed with hot soapy water or placed in the dishwasher If needed mild abrasives may be used Allow grates and caps to dry well before replacing them Use care replacing the burner caps so as not to damage the thermocouple and the hot wire igniter Phone 800 725 7711 www calderacorp com Fax 800 962 3072 10 Warranty Two Year Parts and Labor Five Year Parts Full Two Year Warra
13. safely while you enjoy the advantages of a technologically advanced control to enhance your cooking experience Detailed Operating Instructions All models of the Arrow gastop family are equipped with an electronic Touch Control that senses the user s touch through the ceramic glass panel The control can operate 4 or 5 gas burners depending on the model Each burner has 21 levels of cooking L L 1 2 1 1 1 2 2 2 1 2 H Each burner has an ON OFF selector key an Up arrow key a Down arrow key and a seven segment LED display and a 1 2 level LED indicator Additionally the control has a Lock key that is used to generate a general OFF state for all burners while also locking the keyboard The control is powered by a 120VAC 60Hz properly grounded house outlet Initial Power Up When power is first applied to the unit or restored after a power outage all LED s will flash 8s in a sequential pattern for a maximum period of 30 seconds or until a key is touched The flashing will then stop and the LED in the R will be lit indicating the gastop is unlocked and ready to use Unlocked mode When the gastop is in Unlocked mode Lock LED is on all keys are potentially active but the Up and Down keys are temporarily inactive unless a burner is in programming mode During Unlocked mode the Lock LED under the Caldera logo is on solid indicating that the burners can now be programmed T

Download Pdf Manuals

image

Related Search

Related Contents

MD100A1 Operation Ma..  5. Modes de transmission  AplusCase CS-Black Pearl II  MOLATRICE ANGOLARE REBARBADORA ANGULAR  TPーD407 取扱説明書  PEAK JCTD OPS Manual - Spiral 2  Operating instructions hawos Easy  Original- Bedienungsanleitung  EK02B.12 L-Z EK02B.19 L-Z Betriebsanleitung Für die autorisierte  INSTALLATION MANUAL  