Home

Broan ELITE E54000 User's Manual

image

Contents

1. SERRATED WASHERS ay MOUNTING SCREWS 3 9x9 5mm FIG 18 CONNECT THE DUCTWORK 6 DUCTED GA nil RARER IAL LL CONNECTION Duct tape all connecton s to make them secure and air tight DUCTED HOODS ONLY 1 Connect 6 diameter metal duct to ducting that discharges to the outside NON DUCTED HOODS ONLY 2 Connect 5 diameter expandable metal duct from the non ducted plenum to the adapter on the blower discharge DUCTED AND NON DUCTED HOODS 3 Remove the tape from the lower flue ee Lower the flue until is seats on top of the 1 hood 5 NON DUCTED 4 Remove duct tape from upper and lower CONNECTION FIG 19 flue Lower the flue until it seats on top of the hood INSTALL ELECTRICAL A WARNING Electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards This range hood must be properly grounded Turn off electrical power at service entrance before wiring 1 Remove the wiring box cover Fig 20 2 Run 2 wire plus ground power cable through the round opening in the support frame bracket and into the wiring box 3 Secure cable to box with an appropriate cable connector Feed the range hood s power cable through the hole in the bottom of the wiring box Secure the cable to the box using the wire clamp supplied in the parts bag Connect wires white to white black to black and green to ground Push w
2. COCCI N Las restricciones de montaje se explican en Preparaci n del armaz n de soporte FIG 5 VIGAS DEL TECHO ENTRAMADO 81 16 205mm FRONTAL TIRAFONDS 6x70mm FIG 6 VISTA SUPERIOR DEL ARMAZ N DE SOPORTE 81 16 205mm RANURA B 51 16 151mm 3 75 5 315 46 100mm FIG 7 PREPARACION DEL ARMAZON DE SOPORTE JA TECHOS DE 8 O 9 PIES RANURAS DE O 1 Retire los cuatro tornillos y arandelas de Ajuste la longitud total del armaz n de Vuelva a colocar los cuatro tornillos y r AJUSTE DE LA Mida la altura del techo y determine la ALTURA distancia entre la encimera y la parte inferior de la campana A las ranuras de ajuste de la altura Figura 8 soporte de acuerdo con la tabla Figura 8 arandelas de las ranuras de ajuste de la PARTE altura Figura 8 FRONTAL FIG 8 METODO DE DISTANCIA DE LA CAMPANA POR ENCIMA DE 36 SOBRE LA SUPERFICIE DE LA COCINA V ASE lanoaa CONDUCTO 24 25 26 27 28 29 30 LONGITUD DE L ARMAZON DE SOP RTE DIMENSION A CON CONDUCTO 21 SIN CONDUCTO 21 CON CONDUCTO Y SIN CONDUCTO CON CONDUCTO Y SIN CONDUCTO Notas La distancia m nima de la campana por encima de la encimera debe ser de 24 como m nimo Para capturar ptimamente las impurezas de cocci n se recomienda u
3. In USA BROAN Hartford Wisconsin In CANADA BROAN Drummondville QC Canada REGISTER YOUR PRODUCT ONLINE AT www Broan com register For additional Information visit www Broan com 99043938E READ AND SAVE THESE INSTRUCTIONS A INTENDED FOR DOMESTIC COOKING ONLY amp WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accor dance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equip ment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities
4. VERT VERT FIG 20 26 INSTALLATION DES FILTRES HOTTES A EVACUATION ET A RECIRCULATION 1 Pourretirerle filtre GRAISSES abaisser la languette du taquet et incliner vers le bas 2 Pour replacer le filtre GRAISSES aligner les languettes arri re du filtre avec les fentes de la hotte Abaisser la languette vers le bas pousser le filtre FILTRES pour le remettre en place puis rel cher GRAISSES FIG 21 V rifier que le filtre soit bien plac REMARQUE Avant l utilisation retirer le film de protection du cadre du filtre ee RECIRCULATION SEULEMENT Pour retirer le filtre CHARBON appuyer sur le taquet frontal du filtre Abaisser le filtre pour d gager ses languettes arri re 2 Pourinstallerle filtre CHARBON aligner les languettes arri re du filtre avec les fentes de la hotte Pousser le filtre pour le mettre en place jusqu ce que le taquet frontal s emboite compl tement dans la LOQUET DE fente V rifier que le filtre soit bien plac BLOCAGE 3 Remettre en place le filtre GRAISSES FILTRE CHARBON apr s avoir install le filtre charbon FIG 22 GARANTIE GARANTIE LIMIT E DE UN AN DE BROAN Broan NuTone LLC Broan NuTone garantit l acheteur original que les produits BROAN vendus en vertu de la pr sente sont libres de tout vice de mat riau ou de fabrication pour une p riode de un an compter d
5. TRE TENUE RESPONSABLE DE TOUT DOMMAGE INDIRECT CONS CUTIF OU ACCES SOIRE D COULANT DE L UTILISATION OU DU RENDEMENT DU PRODUIT Certains tats ou provinces interdisent l exclusion ou la restriction des dommages indirects ou cons cutifs La restriction susmentionn e peut donc ne pas s appliquer dans votre cas La pr sente garantie vous conf re des droits sp cifiques reconnus par la loi D autres droits pourraient galement vous tre accord s selon la l gislation locale en vigueur La pr sente garantie remplace toutes les autres garanties pr c dentes Pour le service sous garantie vous devez a aviser Broan NuTone l une des adresses ou num ros de t l phone mentionn s ci dessous b indiquer le num ro de mod le et d identification de la pi ce et c d crire la d fectuosit du produit ou de la pi ce Lors d une r clamation vous devez pr senter une preuve de la date d achat originale In USA Broan 926 W State Street Hartford WI 53027 800 558 1711 In Canada Broan 550 Lemire Blvd Drummondville QC J2C 7W9 866 737 7770 www Broan com LEA Y CONSERVE ESTAS INSTRUCCIONES INDICADO PARA EL USO EN COCINAS DOMESTICAS ADVERTENCIA PARA EVITAR EL RIESGO DE INCENDIO CORTOCIRCUITO O DANO PARA LAS PERSONAS OBSERVE ATENTAMENTE LAS SIGUIENTES NORMAS 1 Use esta unidad solamente de la manera indicada por el fabricante si tiene dudas p ngase en contacto con ste a la direcci n o tel fono i
6. pour les restrictions relatives au montage 9 En raison de la grande dimension et du poids de cet appareil il est recommand de confier l installation de cette hotte deux personnes 10 Ce produit est dot d un thermostat pouvant activer automatiquement le ventilateur Pour r duire le risque de blessures et viter l activation accidentelle coupez le courant depuis le panneau d alimentation lectrique et verrouillez ou apposez un avertissement sur le panneau 11 Cette hotte ne doit tre utilis e qu avec un ensemble de cordon d alimentation approuv 12 Nous vous recommandons de lire l tiquette indiquant les caract ristiques de votre hotte pour de plus amples renseignements et exigences ako 16 FONCTIONNEMENT INTERRUPTEUR INTERRUPTEUR ces D CLAIRAGE Commandes DU VENTILATEUR La hotte fonctionne a l aide des boutons coulissants situ s sous la partie inf rieure de la hotte nine Linterrupteur d clairage allume et teint les lampes L interrupteur du ventilateur active le ventilateur trois r gimes diff rents 0 1 0123 O 0 ARR T a l 1 BASSE VITESSE 2 MOYENNE VITESSE 3 HAUTE VITESSE FIG 1 Le voyant lumineux s allume quand le ventilateur fonctionne HEAT SENTRY C Votre hotte est munie d un thermostat HEAT SENTRY C Ce thermostat est un dispositif qui actionnera ou augmentera la vitesse du ventilateur s il d tecte une chaleur excessive au dessus
7. Be sure to mark the location of the ceiling joists and cross framing 3 Secure the support frame bracket to joists and cross framing with four lag bolts provided 6x70mm and four washers 6 4mm Make sure screws are driven into center of joists and framing for maximum strength Be careful because the position of the bracket determines the final position of the hood the side with the slot B corresponds to the controls side Fig 2 ROOF CAP 24 to 30 ABOVE COOKING SURFACE See Prepare Support Frame section for mounting restriction FIG 5 SLOT B CROSS FRAMING CEILING JOISTS WASHERS 96 4mm LAG BOLTS 6x70mm FIG 6 TOP VIEW OF SUPPORT FRAME 81 16 315 16 51 16 FIG 7 PREPARE SUPPORT FRAME 8 AND 9 FOOT CEILINGS q 1 Measure the ceiling height and determine HEIGHT J distance between the cook top and bottom cp al of hood 2 Remove 4 screws and washers in the height adjustment slots Figure 8 3 Per the chart adjust overall lenght of the support frame Figure 8 4 Reinstall 4 screws and washers in the height adjustment slots Figure 8 HOOD DISTANCE ABOVE 36 HIGH COOK TOP See note a DUCT METHOD 24 25 2 27 28 298 LENGHT OF SUPPORT FRAME DIMENSION A PA 21 DUCTED NON DUCTED DUCTED amp NON DUCTED DUCTED amp NON DUCTED
8. FIG 13 MONTAJE DE LA CHIMENEA DECORATIVA SUPERIOR S LO PARA CAMPANAS CON CONDUCTO TECHOS DE 8 O 9 PIES 1 Monte y fije la chimenea superior al armaz n de soporte con dos tornillos de montaje de 2 9 x 9 5 mm Fig 15 En techos de 8 pies m ntela con los respiraderos abajo En techos de 9 pies m ntela con los respiraderos arriba TECHOS DE 10 PIES 2 Deseche la chimenea superior suministrada con la campana Sustit yala por la chimenea superior incluida en la extensi n de chimenea modelo FX54SS Monte y fije la chimenea superior al armaz n de soporte con dos tornillos de montaje de 2 9 x 9 5 mm 37 CONECTOR CONDUCTO MET LICO FIG 14 TORNILLOS DE MONTAJE 2 9x9 5mm RESPIRA DEROS ARRIBA RESPIRA DEROS ABAJO MONTAJE DE LA CHIMENEA DECORATIVA SUPERIOR Cont SOLO PARA CONDUCTO TECHOS DE 8 O 9 PIES 4 Monte la chimenea superior con los respiraderos arriba Fijela al armaz n de soporte con dos tornillos de montaje de 3 9 x 9 5 mm Fig 16 TECHOS DE 10 PIES 5 Deseche la chimenea superior suministrada con la campana Sustit yala por la chimenea superior incluida en la extensi n de chimenea modelo FXN54SS 6 Monte la chimenea con los respiraderos arriba y f jela al armaz n de soporte con dos tornillos de montaje de 2 9 x 9 5 mm CAMPANAS SIN MONTAJE DE LA CHIMENEA DECORATIVA INFERIOR 1 Desl
9. Retirer le ruban du conduit d coratif inf rieur et sup rieur Abaisser le conduit jusqu ce qu il repose sur la partie sup rieure de la hotte INSTALLATION LECTRIQUE ATTENTION le c blage lectrique doit tre effectu par une personne qualifi e en vertu des codes et des normes en vigueur La hotte doit tre correctement reli e la terre Coupez l alimentation lectrique avant de proc der au c blage 1 Retirer le couvercle de la bo te de connexion lectrique Fig 20 2 Passer le cable lectrique bifilaire plus mise la terre par l ouverture ronde de la bride de la structure de support puis dans la boite de connexion lectrique 3 Fixer le fil dans la boite de connexion lectrique avec un serre fils appropri 4 Enfiler le cable d alimentation de la hotte dans le trou se trouvant au fond de la boite de connexion lectrique 5 Fixer le cable la bo te avec le serre fils inclus dans le sachet des pi ces Raccorder les fils BLANC avec BLANC NOIR avec NOIR et VERT avec mise ala terre Placer les fils dans la boite de branchement Remettre en place le couvercle sur la boite de connexion lectrique 8 Soulever le conduit d coratif sup rieur et remettre en place les vis de montage RACCORD D EVACUATION A RACCORD DE RECIRCULATION 5 FIG 19 NO COUVERCLE DE LA BO TE DE CONNEXION LECTRIQUE Le NOIR NOIR D oa LIGNE DE 120 V 60 HZ SERRE FILS
10. When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors Do not use this unit with any separate solid state speed control device To reduce the risk of fire use only metal ductwork This unit must be grounded O REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when cooking flaming foods i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe as ventilating fans frequently Grease should not be allowed to accumulate on fan or ilter Use proper pan size Always use cookware appropriate for the size of the surface element odo OMND al U O BD gt WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels violent steam explosion will result 4 Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you
11. 297 297 Notes a Minimum hood distance above cook top must not be less than 24 A maximun of 30 above cook top is highly recommended for best capture of cooking impurities Distances over 30 are at the installers and user s discretion providing that ceiling height and flue length permit b Requires optional 10 foot flue extension 10 FOOT CEILINGS Note The following materials must be purchased separately for 10 foot ceiling installations e Flue extension model FX54SS for ducted installations e Flue extension model FXN54SS for non ducted installations 5 Discard the upper support frame half supplied with the range hood Replace with the longer upper support frame supplied with the flue extension 6 Follow steps 1 through 4 shown above PREPARE SUPPORT FRAME cont d 7 Hang the support frame from the support frame bracket located on ceiling Securely fasten with 4 3 9x9 5mm mounting screws Fig 9 PREPARE THE HOOD DUCTED AND NON DUCTED HOODS 1 Assemble the Electrical Mounting Plate to the hood with 2 3 9x9 5mm mounting screws and 2 serrated washers Fig 10 DUCTED HOODS ONLY 2 Install the plastic discharge collar into the opening of the blower discharge Fig 11 Install 6 diameter metal duct over the blower discharge It must be long enough to reach ducting that discharges to the outside Duct tape all joints to make them secure and air ti
12. VERIFIER QUE LE FUSIBLE SOIT EN BON ETAT PUIS LE REMPLACER AU BESOIN 1 2 3 Retirer les filtres a graisses Retirer le couvercle de la boite du fusible Localiser le porte fusible D visser sa calotte et retirer le fusible Installer un fusible de m me taille et de m me intensit 5 x 20 mm 4 A 125 V Ne pas utiliser de fusibles plus puissants que 4 amp res Des fusibles de plus de 4 amp res peuvent abimer le transformateur Remettre en place le capuchon du porte fusible le couvercle de la boite du fusible et les filtres a graisses R tablir l alimentation lectrique au point d origine de l installation lectrique 18 BO TIER DU FUSIBLE FUSIBLE FIG 3 ENTRETIEN Un bon entretien de votre hotte garantira une excellente performance Filtres a graisses E e Les filtres graisses doivent tre nettoy s fr quemment Utiliser une solution d eau chaude additionn e de d tergent Les filtres graisses peuvent tre lav s au lave vaisselle Voir la section INSTALLATION DES FILTRES pour les instructions relatives au d montage et l installation Filtre charbon Le filtre charbon pour hottes recirculation doit tre chang tous les 6 mois Voir la section INSTALLATION DES FILTRES pour les instructions relatives au d montage et l installation Nettoyage de votre hotte L acier inoxydable est l une des mati
13. already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA eee A CAUTION N D NAO 9 10 11 12 For indoor use only To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages Take care when using cleaning agents or detergents Avoid using food products that produce flames under the Range Hood For general ventilating use only Do not use to exhaust hazardous or explosive materi als and vapors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced For best capture of cooking impurities the bottom of the hood should be a minimum of 24 and a maximum of 30 above the cooking surface See Prepare Support Frame section for mounting restrictions Two installers are recommended because of the large size and weight of this hood This product is equipped with a thermostat which may start blower automatically
14. d air au diam tre plus grand 4 Installer un capuchon de toit ou de mur Relier le conduit circulaire en m tal au capuchon puis acheminer le conduit jusqu l emplacement de votre hotte Sceller herm tiquement les joints l aide de ruban conduits INSTALLATION DU SYSTEME DE SUPPORT 1 Installer l emplacement de votre hotte une charpente de 2 po x 4 po entre les solives du plafond selon les dimensions indiqu es 2 Compl ter la finition du plafond Vous assurer de bien marquer l emplacement des solives du plafond et de la charpente 8 Fixer la bride de la structure de support aux solives et la charpente au moyen des quatre tire fond 6 x 70 mm et des quatre rondelles 6 4 mm de diam tre fournies S assurer que les vis soient bien centr es dans les solives et dans la charpente pour que tout soit bien solide Faites attention le positionnement de la bride d termine la position finale de la hotte le c t avec la fente B correspond au c t des commandes Fig 2 21 CAPUCHON DE TOIT CONDUIT DECORATIF DE 24 PO 61 CM a 30 PO 76 CM AU DESSUS DU PLAN DE CUISSON Voir la section Pr paration de la structure de support pour les restrictions relatives CONDUIT ROND A EGETETE TESEI TILT A i KN ZLLLLLIL II LIT TITI III IT TITI TITI III ITA au montage FIG 5 SURFACE DU PLAFOND CHARPENTE 8 the po 205 mm DEVANT Su TIRE FOND 6
15. de la surface de cuisson 1 Si le ventilateur n est pas en marche il actionnera le ventilateur en haute vitesse 2 Si le ventilateur fonctionne en basse vitesse le ventilateur passera en haute vitesse Lorsque la temp rature revient la normale le ventilateur retourne sa vitesse d origine AVERTISSEMENT Le thermostat HEAT SENTRY C peut activer le ventilateur m me si la hotte est arr t e Si tel est le cas il est impossible d arr ter le ventilateur depuis son interrupteur Si vous devez arr ter le ventilateur faites le depuis le panneau lectrique principal AMPOULES HALOG NES Ce mod le de hotte requiert 4 ampoules halog nes type T3 12 V 20 W max base G 4 AVERTISSEMENT Avant de proc der quelconque op ration d branchez toujours l appareil Pour remplacer les ampoules 1 D visser la bague dans le sens contraire des aiguilles d une montre 2 Retirer l ampoule en tirant sur le c t NE PAS LA TOURNER Aca L ampoule peut tre chaude 3 Remplacer par une ampoule de m mes caract ristiques T3 12 V 20 W max base G 4 Ne touchez pas l ampoule neuve mains FIG 2 nues Ne pas employer d ampoules plus puissantes que 20 watts Des ampoules de plus de 20 watts br leront le fusible 72 REMPLACEMENT DU FUSIBLE SI LES LAMPES NE FONCTIONNENT PAS DECONNECTER L ALIMENTATION ELECTRIQUE AU POINT D ORIGINE DE L INSTALLATION LECTRIQUE
16. permettent b Une rallonge de conduit en option pour plafond de 10 pi est essentielle PLAFONDS DE 10 PI Remarque le mat riel suivant doit tre achet s par ment pour les installations au plafond de 10 pi e Rallonge de conduit mod le FX54SS pour les hottes vacuation Rallonge de conduit mod le FXN54SS pour les hottes a recirculation al Laisser de c t la moiti sup rieure de la structure de support accompagnant la hotte et la remplacer par la moiti sup rieure plus longue de la structure de support accompagnant la rallonge de conduit 6 Suivre les tapes 1 a 4 ci dessus 20 PREPARATION DE LA STRUCTURE DE SUPPORT suite 7 Suspendre la structure de support a la bride de la structure au plafond Bien serrer avec les 4 vis de montage de 3 9 mm x 9 5 mm Fig 9 PREPARATION DE LA HOTTE HOTTES A EVACUATION ETA RECIRCULATION 1 Assembler la plaque d installation lectrique a la hotte en utilisant les 2 vis de montage de 3 9 mm x 9 5 mm et les 2 rondelles dent es Fig 10 HOTTES A EVACUATION SEULEMENT 2 Installer le collier d vacuation dans louverture du conduit d vacuation Fig 11 3 Installer le conduit m tallique de 6 po de diam tre la sortie du ventilateur Il doit tre assez long pour atteindre le conduit d bouchant lair libre Sceller herm tiquement les joints l aide de ruban conduits HOTTES RECIRCULATION SEULEMENT Remarque
17. personas cualificadas y conforme a todos los c digos y normas aplicables Esta campana de cocina debe disponer de conexi n a tierra Desconecte la corriente el ctrica por la toma de servicio antes de cablear 1 Retire la tapa de la caja del cableado Fig 20 2 Tienda un cable de dos conductores y tierra a trav s de la abertura de la brida del armaz n de soporte y hacia dentro de la caja del cableado Fije el cable a la caja con un conector para cables adecuado Alimente el cable de corriente de la campana extractora a trav s del orificio de la parte inferior de la caja del cableado Fije el cable a la caja con el sujeta cable incluido en la bolsa de herrajes Conecte los cables blanco con blanco negro con negro y verde a tierra Empuje el cableado hacia dentro de la caja el ctrica Vuelca a colocar la tapa de la caja del cableado 8 Levante la chimenea superior y vuelva a colocar los tornillos de montaje CINTA ADHESIVA NOOO AU L NEADEENTRADA 120 V 60 HZ CUBIERTA DE LA CAJA DEL CABLEADO NEGRO NEGRO Wy BLANCO BLANCO VERDE VERDE FIG 20 39 INSTALACION DE FILTROS CONFIGURACION CON CONDUCTO Y de CONDUCTO Para quitar el filtro de GRASA agarre con fuerza la leng eta del seguro y tire de ella 2 Para instalar el filtro de GRASA alinee las leng etas posteriores del filtro con las ranuras de la campana Tire de la leng eta del
18. res les plus faciles nettoyer Un entretien occasionnel permettra de le conserver en parfait tat Conseils pour le nettoyage e Eau chaude et savon ou d tergent c est tout ce qui est normalement n cessaire e Apr s chaque nettoyage rincer bien l eau claire Essuyer avec un chiffon propre et doux pour viter les taches d eau e Si des d colorations ou des d p ts persistent utiliser un nettoyant domestique non abrasif ou de la poudre pour Pacier inoxydable avec un peu d eau et un chiffon doux e Dans les cas difficiles utiliser une ponge en plastique ou une brosse douce avec du nettoyant et de l eau Frotter l g rement en suivant la direction du polissage ou du grain de l acier inoxydable Eviter de frotter trop fort pour ne pas ab mer la surface e NE PAS LAISSER les taches sur place trop longtemps e NE PAS UTILISER de laines d acier ordinaires ou de brosses en acier Des d bris d acier pourraient adh rer la surface et causer de la rouille e NE PAS LAISSER trop longtemps des solutions salines des d sinfectants des blanchissants ou des produits nettoyants en contact avec l acier Beaucoup de ces produits contiennent des produits chimiques qui pourraient causer des dommages Rincer Peau imm diatement s ils entrent en contact puis essuyer avec un chiffon humide Les surfaces peintes doivent tre nettoy es avec de leau ti de additionn e d un d tergent doux seulement 19 PR
19. x 70 mm FENTE B FIG 6 SOLIVES DU PLAFOND RONDELLES 6 4 mm 3 5 16 po 100 mm VUE DE HAUT DE LA STRUCTURE DE SUPPORT 8 the po 205 mm PREPARATION DE LA STRUCTURE DE SUPPORT CA PLAFONDS DE 8 PI ET DE 9 PI FENTE POUR J 1 Mesurer la hauteur de plafond et tablir la PEGTASEEN distance entre la surface de cuisson et le bas de la hotte 2 Enlever les 4 vis et rondelles des fentes de r glage de hauteur Figure 8 3 R gler la longueur g n rale de la structure de support selon le graphique Figure 8 4 Remettre en place les 4 vis et rondelles dans les fentes de r glage de hauteur Figure 8 FIG 8 M THODE ESPACEMENT ENTRE LA HOTTE ET LE PLAN DE CUISSON DE 36 po DE HAUT Voir note a D INSTALLATION 24 25 26 27 28 29 30 DES CONDUITS LONGUEUR DE LA STRUCTURE DE SUPPORT DIMENSION A EVACUATION 22 po 21 po RECIRCULATION 22 po 21 po EVACUATION ET RECIRCULATION EVACUATION ET RECIRCULATION Notes a La distance minimale de la hotte au dessus du plan de cuisson ne doit pas tre inf rieure 24 po Un maximum de 30 po au dessus du plan de cuisson est fortemment recommand pour mieux capter les odeurs de cuisson Des distances sup rieures 30 po sont la discr tion de l installateur et de l utilisateur et si la hauteur du plafond et la longueur du conduit le
20. CONDUIT MONTAGE DU CONDUIT D CORATIF SUP RIEUR HOTTES VACUATION SEULEMENT PLAFONDS DE 8 PI ET DE 9 PI 1 Installer et fixer le conduit d coratif sup rieur sur la structure de support avec les 2 vis de montage de 2 9 x 9 5 mm Fig 15 e Pour les plafonds de 8 pi installer avec la grille d a ration en bas e Pour les plafonds de 9 pi installer avec la grille d a ration en haut PLAFONDS DE 10 PI 2 Ne pas utiliser le conduit d coratif sup rieur accompagnant la hotte le remplacer par la rallonge de conduit mod le FX54SS 3 Installer et fixer la rallonge de conduit sup rieur sur la structure de support avec les 2 vis de montage de 2 9 x 9 5 mm 24 VIS DE MONTAGE 2 9 x 9 5 mm A GRILLE D A RATION ENBAS CONDUIT D CORATIF SUPERIEUR FIG 15 MONTAGE DU CONDUIT DECORATIF SUPERIEUR suite HOTTES A RECIRCULATION SEULEMENT PLAFONDS DE 8 PIET DE 9 PI 4 Installer le conduit d coratif sup rieur avec la grille d a ration en haut Fixer sur la structure de support avec les 2 vis de montage de 2 9 x 9 5 mm Fig 16 PLAFONDS DE 10 PI 5 Ne pas utiliser le conduit d coratif accompagnant la hotte le remplacer par la rallonge de conduit mod le FXN54SS 6 Installer avec la grille d a ration en haut et fixer a la structure de support avec les 2 vis de montage de 2 9 x 9 5 mm MONTAGE DU CONDUIT DECORATIF I
21. EPARATION DE LA HOTTE Retirer la hotte de l emballage puis v rifier le contenu Vous devez recevoir 1 Hotte 1 Conduit d coratif 1 Structure de support 1 Sachet avec 1 Bride de la structure de support COLLIER 23 D VACUATION 1 Collier d vacuation BRIDE DE LA 4 Tire fond 6 x 70 mm STRUCTURE 14 Vis de montage 3 9 x 9 5 mm t te ronde DE SUPPORT 2 Vis de montage 2 9 x 9 5 mm t te ronde 4 Rondelles 6 4 mm de diam tre 6 Rondelles dent es 1 Couvercle de bo te de connexion lectrique 1 Serre fils 1 Instructions d installation SERRE FILS gt COUVERCLE DE LA BOITE DE CONNEXION ELECTRIQUE 4 TIRE FOND 6 x 70 mm GU STRUCTURE DE SUPPORT CONDUIT D CORATIF 14 VIS DE MONTAGE 3 9 x 9 5 mm t te ronde 6 RONDELLES diam tre 2 9 x 9 5 mm t te ronde 20 INSTALLATION DU SYSTEME DE CONDUITS HOTTES A EVACUATION EXTERIEURE SEULEMENT A ATTENTION Pour r duire les risques d incendie n utilisez que des conduits en m tal 1 D terminer par o passera le conduit entre votre hotte et l ext rieur 2 Un conduit droit et court permettra votre hotte de fonctionner plus efficacement 8 Un conduit long avec des coudes et des transitions r duira la performance de votre hotte En utiliser le moins possible Pour une grande distance il faut un conduit d vacuation
22. NFERIEUR 1 Faire glisser le conduit d coratif inf rieur vers le haut et par dessus le conduit sup rieur jusqu ce qu il touche le plafond Fixer provisoirement les deux moiti s avec du ruban pour conduits Fig 17 INSTALLATION DE LA HOTTE A ATTENTION En raison de la grande dimension et du poids de cet appareil il est recommand de confier l installation de cette hotte deux personnes 1 Fixer la hotte sur la structure du support avec les 6 vis de montage de 3 9 x 9 5 mm et les 2 rondelles dent es Fig 18 25 VIS DE MONTAGE 2 9 x 9 5 mm N CONDU D CORA SUP RIE GRILLE DAERATION EN HAUT FIG 16 j CONDUT g D CORATIF if INFERIEUR RONDELLES DENTEES VIS DE MONTAGE 3 9 x 9 5 mm ay FIG 18 RACCORD DES CONDUITS Sceller herm tiquement tous les joints l aide de ruban a conduits HOTTES A EVACUATION SEULEMENT RUBAN 1 Raccorder le conduit m tallique de 6 po de diam tre aux conduits d vacuation vers l air libre HOTTES A RECIRCULATION SEULEMENT 2 Raccorder le conduit m tallique extensible de 5 po de diam tre allant du d flecteur de recirculation l adaptateur sur le conduit d vacuation HOTTES VACUATION ET RECIRCULATION 3 Retirer le ruban du conduit d coratif inf rieur Abaisser le conduit jusqu ce qu il repose sur la partie sup rieure de la hotte 4
23. O A NOTA para evitar el riesgo de incendio use solamente material de metal 1 Decida donde va a colocar el tubo de extracci n entre la campana y la parte exterior 2 Un recorrido de tubo corto y recto permitira a la campana funcionar de manera mas eficaz 3 Los recorridos largos de tubo codos y manguitos impiden el buen funcionamiento de la campana Use el menor n mero de ellos posible Para usos prolongados es necesario un tubo de evacuaci n del aire de mayor di metro 4 Instale una cubierta una tapa Una el tubo de metal a la cubierta y retroceda hasta la posici n de la campana Use une cinta para precintar las juntas entre las partes del entubado INSTALACION DEL SISTEMA DE SUJECION 1 En el sitio donde vaya a ir la campana instale un entramado entre las vigas del techo utilizando las medidas dadas 2 Termine la superficie del techo Aseg rese de marcar la colocaci n de las vigas del techo y del entramado 3 Sujete la placa del armaz n de soporte a las vigas y al entramado con los cuatro tirafonds 6x70mm y cuatro arandelas D 6 4mm Compruebe que los tornillos vayan al centro de las vigas del techo para una mayor rigidez Tener cuidado porque la ubicaci n de la placa determina la posici n final del aparato el lado con la ranura B corresponde al lado comandos Fig 2 34 CUBIERTA DEL TEJADO DECORATIVO ll campana 24 61cm A 30 76cm POR ENCIMA DE LA ZONA DE
24. To reduce the risk of injury and to prevent power from being switched on accidentally switch power off at service panel and lock or tag service panel Use with approved cord connection kit only Please read specification label on product for further information and requirements OPERATION LIGHT Controls SWITCH ane The hood is operated using the slide controls PILOT under the bottom of the hood LAMP The light switch turns the lamps on and off three speed settings 0 OFF 1 LOW SPEED 2 MEDIUM SPEED FIG 1 3 HIGH SPEED The pilot lamp lights up whenever the blower is on The blower switch turn the blower on to HEAT SENTRY Your hood is equipped with a HEAT SENTRY thermostat This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface 1 If blower is OFF it turns blower ON to HIGH speed 2 If blower is ON at a lower speed setting it turns blower up to HIGH speed When the temperature level drops to normal the blower will return to its original setting WARNING The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF When this occurs it is impossible to turn the blower OFF with its switch If you must stop the blower do it from the main electrical panel HALOGEN BULBS This range hood requires 4 halogen bulbs Type T3 12Volt 20 Watt Max G 4 Base WARNING Always switch off t
25. a que descarga al exterior Encinte todas las uniones de los conductos para fijarlos y estanqueizarlos SOLO PARA CAMPANAS SIN CONDUCTO Nota Para las instalaciones de recirculaci n sin conductos deben adquirirse por separado los materiales siguientes e Kit de recirculaci n sin conductos RK54 1 Deseche el casquillo de descarga de pl stico suministrado con la campana Monte el adaptador de 5 o 6 incluido en el kit de recirculaci n sin conducto sobre la descarga del soplador Fig 12 2 Encinte todas las uniones para fijarlas y estanqueizarlas 36 TORNILLOS DE MONTAJE 3 9x9 5mm o PARTE FRONTAL PLACA ARMAZ N DE SOPORTE SN ARMAZ N DE SOPORTE FIG 9 TORNILLOS DE MONTAJE 3 9x9 5mm PLACA DEL SISTEMA ELECTRICO FIG 11 ADAPTADOR 67 5 PREPARACION DE LA CAMPANA cont SOLO PARA CAMPANAS SIN CONDUCTO 3 4 5 Monte el pleno a trav s de la abertura rectangular superior del armaz n de soporte Fig 13 Monte el conector de conductos de 5 de di metro al pleno Gire y bloquee para fijar Fig 14 Fije el conducto expansible met lico de 5 de di metro al pleno Cuando se tire del mismo debe ser suficientemente largo para llegar a la parte inferior del armaz n de soporte Fig 14 Encinte todas las uniones de los conductos para fijarlos y estanqueizarlos PLENO
26. aque int rieure BE3404365 Support B02300729 Transformateur B08086279 Circuit des commandes B03295072 Bo te des commandes B03295074 Interrupteur du moteur B03201014 Voyant B03295075 Couvercle de la bo te des commandes B03295073 Interrupteur d clairage B03295035 Bo tier du fusible BE3404172 Plaque BE3404174 Couvercle BE3344985 Bride du support ventilateur BE3343984 Bride B02300789 Bo tier de la lampe halog ne B03294776 Couvercle de protection du transformateur B080810768 Accessoires de quincaillerie B06108718 Ensemble du panneau de commandes Rep res n 234 228 241 238 229 et 230 B06002126 Bloc ventilateur Rep res n 45 48 49 et 53 B02300782 Fusible B02300674 Porte fusible Illustr d mont 42 LISTA DE PIEZAS DE RECAMBIO MODELO E54000 COD N PIEZAN DESCRIPCION B08087294 Filtro antigrasa B02300233 Condensador BE3348527 Placa del sistema electrico B03295005 Protecci n trasformador B02300891 L mpara hal gena B02300804 Sensor de temperatura B03294033 Tapa de la caja base de instalaci n el ctrica BW0000019 Convoyador B02310260 Motor B03295071 Manilla del motor B03204177 Almohadilla antivibraziones B08091400 Soporte motor BE3348620 Placa armaz n de soporte B08088378 Casquillo B03202179 Guarnici n B02011314 Placa marca BE3334250 Caja del cableado BE3334252 Tapa de la caja del cableado BE3402102 Tubo decorativo inferior BE3402103 Tubo decorativo superior B08092083 A
27. den arder Caliente el aceite a fuego medio o bajo Encienda siempre la campana cuando cocine a fuego alto o cuando cocine alimentos facilmente inflamables por ejemplo Crepes Suzette Cerezas Jubilee Ternera flambeada con granos de pimienta Limpie con frecuencia los ventiladores No se debe acumular grasa en el ventilador o en el filtro Usa el tama p de cazuela apropiado Use siempre utensilios de cocina de tama o y material adecuados ADVERTENCIA PARA EVITAR EL RIESGO DE DANOS A PERSONAS EN CASO DE FUEGO POR ALTO NIVEL DE GRASA TENGA EN CUENTALO SIGUIENTE 1 SOFOQUE LA LLAMA con una tapadera apropiada una bandeja met lica 6 un utensilio de coc na que pueda cubrirla despues apague el quemador ACTUE CON PRECAUCION PARA EVITAR QUEMADURAS Si la llama no se extingue inmedia tamente SALGA Y LLAME A LOS BOMBEROS 2 NUNCA COJA UNA SARTEN EN LLAMAS porque corre el riesgo de quemarse 3 NO USE AGUA ni pa os o toallas h midas porque puede provocarse una violenta humareda 4 Use un extintor SOLAMENTE si A Posee un extintor de clase ABC y sabe perfectamente c mo usarlo B Elfuego es peque o y est controlado en el mismo sitio en que empez C Hallamado con anterioridad a los bomberos D Puede combatir el fuego retroced endo hacia la salida Basado en Seguridad antifuego en la coc na publicado por NFPA DU OONO 28 ADVERTENCIA k PO 9 Para uso en interiores Para reducir
28. e Top Support Frame Wire Clamp Electrical Box Control Board Interior Plate Support Transformer Controls Board Controls Box Motor Switch Pilot Controls Box Cover Light Switch Fuse Box Plate Cover Blower Support Bracket Bracket Halogen Lamp Housing Transformer Protection Cover Hardware Package Switch Box Assembly Includes Keys No 234 228 241 238 229 230 Blower Assembly Includes Keys No 45 48 49 53 Fuse Fuse Holder 41 LISTE DES PIECES DE RECHANGE MODELE E54000 N N DE PIECE DESCRIPTION B08087294 Filtre graisses B02300233 Condensateur du moteur BE3348527 Plaque d installation lectrique B03295005 Protection du transformateur B02300891 Ampoule halog ne B02300804 Capteur thermique HEAT SENTRY B03294033 Couvercle de bo te de la plaque lectronique BW0000019 Ventilateur B02310260 Moteur B03295071 Roue du ventilateur B03204177 Amortisseur en caoutchouc B08091400 Support du ventilateur BE3348620 Bride de la structure du support B08088378 Collier d vacuation B03202179 Joint B02011314 Logo BE3334250 Boite de connexion lectrique BE3334252 Couvercle de la boite de connexion lectrique BE3402102 Conduit d coratif inf rieur BE3402103 Conduit d coratif sup rieur B08092083 Structure de support inf rieure B08092233 Structure de support sup rieure B032920200 Serre fils B03294781 Bo te de branchement B08086668 Carte lectronique BE3344096 Pl
29. e changed every 6 months See INSTALL FILTERS sectionfor removal and installation instructions Hood Cleaning Stainless steel is one of the easiest materials to keep clean Occasional care will help preserve its fine appearance Cleaning tips e Hot water with soap or detergent is all that is usually needed e Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks e For discolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth e For stubborn cases use a plastic scouring pad or soft bristle brush together with cleanser and water Rub lightly in direction of polishing lines or grain of the stainless finish Avoid using too much pressure which may mar the surface e DO NOT allow deposits to remain for long periods of time e DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust e DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these com pounds contain chemicals which may be harmful Rinse with water after expo sure and wipe dry with a clean cloth Painted surfaces should be cleaned with warm water and mild detergent only PREPARE THE HOOD Unpack hood and check contents You should receive 1 Hood 1 Decorative Flue Ass
30. e la date d achat originale CETTE GARANTIE NE COMPORTE AUCUNE AUTRE GARANTIE EXPRESSE OU TACITE Y COMPRIS MAIS SANS S Y LIMITER LES GARANTIES TACITES DE VALEUR MARCHANDE O D ADAPTATION UN USAGE PARTICULIER Durant cette p riode de un an Broan NuTone r parera ou remplacera gratuitement sa discr tion tout produit ou toute pi ce jug s d fectueux dans des conditions normales d utilisation CETTE GARANTIE NE S APPLIQUE PAS AUX TUBES FLUORESCENTS ET AUX STARTERS NI AUX AMPOULES HALOGENES OU INCANDESCENTES FUSIBLE FILTRES CONDUITES CHAPEAUX DE TOIT CHAPEAUX DE MUR ET AUTRES ACCESSOIRES POUR CANALISATIONS Cette garantie ne couvre pas a les frais d entretien ou de service normaux ni b tout produit ou toute pi ce soumis une utilisation inad quate une n gligence un accident un entretien ou une r paration inad quats autres que ceux effectu s par Broan NuTone une mauvaise installation ou une installation contraire aux instructions recommand es La dur e de toute garantie tacite est limit e la p riode de un an stipul e pour la garantie expresse Certains Etats ou provinces ne permettent pas de limites quant la dur e d une garantie implicite La restriction susmentionn e peut donc ne pas s appliquer dans votre cas BROAN NUTONE S L OBLIGATION POUR BROAN NUTONE DE R PARER OU DE REMPLACER LE PRODUIT SA DISCR TION CONSTITUE LE SEUL RECOURS DE L ACHETEUR EN VERTU DE CETTE GARANTIE BROAN NUTONE NE PEUT PAS
31. ed deber a Avisar a la direcci n abajo indicada bien llamar por tel fono b Dar el n mero de serie del modelo correspondiente o bien una descripci n de la parte averiada c Descripci n del defecto en el producto o bien en una de sus partes Para requerir un servicio en garant a debe presentar el justificante con la fecha de la compra In USA Broan 926 W State Street Hartford WI 53027 800 558 1711 In Canada Broan 550 Lemire Blvd Drummondville QC J2C 7W9 866 737 7770 www Broan com SERVICE PARTS MODEL E54000 KEY NO PART NO DESCRIPTION B08087294 B02300233 BE3348527 B03295005 B02300891 B02300804 B03294033 BW0000019 B02310260 B03295071 B03204177 B08091400 BE3348620 B08088378 B03202179 B02011314 BE3334250 BE3334252 BE3402102 BE3402103 B08092083 B08092233 B032920200 B03294781 B08086668 BE3344096 BE3404365 B02300729 B08086279 B03295072 B03295074 B03201014 B03295075 B03295073 B03295035 BE3404172 BE3404174 BE3344985 BE3343984 B02300789 B03294776 B080810768 B06108718 B06002126 B02300782 B02300674 Not shown assembled Grease Filter Motor Capacitor Electrical Mounting Plate Transformer Protection Halogen Lamp Bulb Heat Sentry Control Board Box Cover Blower Motor Blower Wheel Rubber Washer Blower Support Support Frame Bracket Discharge Collar Gasket Nameplate Wiring Box Wiring Box Cover Decorative Flue Bottom Decorative FlueTop Bottom Support Fram
32. el interruptor del panel de servicio en la posici n OFF y bloquear el panel de servizio o colocar una advertencia externa como por ejemplo un letrero o una chapita 11 Use solamente con juego de conexi n para alimentaci n aprobado 12 Se recomienda leer la placa de caracteristicas del producto para ulterior informaci n 29 FUNCIONAMIENTO INTERRUPTOR Mandos INTERRUPTOR DEL ASPIRADOR La campana se controla mediante los DALUZ mandos corrrederos situados en la parte PILOTO inferior de la misma El interruptor da luz enciende y apaga las l mparas El interruptor del aspirador enciende el ga 2s ventilator en uno de los siguientes ajustes de a l velocidad O APAGADO 1 VELOCIDAD BAJA FIG 1 2 VELOCIDAD MEDIA 3 VELOCIDAD ALTA El piloto se enciende cuando el aspirador est funcionando HEAT SENTRYMR Su campana esta equipada con termostato HEAT SENTRYMR Este termostato tiene un mecanismo que se encender o acelerat el ventilador si se detecta un calor excesivo encima de la cocina 1 Si el ventilador esta apagando el se prender a una velocidad m xima 2 Si el ventilador esta encendido a una velocidad minima el se prender a una velocidad m xima Cuando la temperatura disminuye a un nivel normal el ventilador vuelve a la funci n de origen A AVERTENCIA El HEAT SENTRYmr termostato puede comenzar a funcionar al igual si la campana esta parada En este caso es impo
33. el riesgo de incendios y para evacuar correctamente los humos asegurarse de haber realizado una conducci n del aire hasta el exterior No expulsar los humos en espacios cerrados por paredes o techos ticos espacios angostos o garajes Prestar la m xima atenci n al utilizar productos de limpieza o detergentes Evitar el uso de productos alimentarios que puedan inflamarse bajo la campana S lo para ventilaci n total No use gases de escape peligrosos o materiales y vapores explosivos Para evitar da os en el funcionamiento del motor e impulsores ruidosos y o desequi librados mantenga alejados de la unidad de encendido pulverizadores en seco o polvo El motor tiene un nivel de sobrecarga t rmica que apaga autom ticamente el motor cuando se ha recalentado excesivamente El motor se pone de nuevo en fincionamento cuando la temperatura baja Si el motor comienza a encenderse y a apagarse deber hacer una revisi n de ste Para limpiar mejor las impurezas al cocinar la distancia entre la parte inferior de la campana y la zona de cocci n debe ser m nimo 24 maximo 30 Las restricciones de montaje se explican en Preparaci n del armaz n de soporte Debido a su gran tama o y peso se recomienda su montaje por parte de dos t cnicos esperializados 10 Este producto est dotado de un termostato que pone en marcha autom ticamente el motor Para reducir el riesgo de da os y evitar que se encienda accidentalmente colocar
34. embly 1 Support Frame 1 Parts Bag containing 1 Support Frame Bracket 1 Discharge Collar 4 Lag Bolts 6 x 70mm 14 Mounting Screws 3 9 x 9 5mm Pan Head 2 Mounting Screws 2 9 x 9 5mm Pan Head 4 Washers 6 4mm Diameter 6 Serrated Washers 1 Wiring Box Cover 1 Wire Clamp 1 Installation Instructions DISCHARGE COLLAR Ve SUPPORT FRAME BRACKET WIRE CLAMP WIRING BOX COVER D LAG BOLTS 6 x 70mm GA al DECORATIVE SUPPORT FLUE FRAME 14 MOUNTING SCREWS 3 9 x 9 5mm Pan Head Q 4 WASHERS 6 SERRATED 2 MOUNTING 6 4mm WASHERS SCREWS 2 9 x 9 5mm Pan Head INSTALL THE DUCTWORK DUCTED HOODS ONLY A CAUTION To reduce the risk of fire use only metal ductwork 1 Decide where the ductwork will run between the hood and the outside 2 A straight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible Larger ducting may be required for best performance with longer duct runs 4 Install a roof or wall cap Connect round metal ductwork to cap and work back to wards hood location Use duct tape to seal the joints between ductwork sec tions INSTALL SUPPORT SYSTEM 1 At hood location install 2 X 4 cross framing between ceiling joists using dimensions shown 2 Finish the ceiling surface
35. es d versements graisseux pouvant s enflammer Chauffez l huile lentement feu doux ou moyen B Mettez toujours la hotte en marche lorsque vous cuisinez feu vif ou que vous cuisinez des mets flamb s par ex cr pes Suzette cerises jubil steak au poivre flamb C Nettoyez r guli rement la roue du moteur de ventilateur Ne laissez pas la graisse s accumuler sur le ventilateur ou le filtre D Utilisez le bon format de casserole Servez vous toujours d ustensiles de cuisson appropri s la dimension de la surface chauffante AVERTISSEMENT AFIN D VITER TOUS RISQUES DE BLESSURE LORS D UN FEU DE CUISINI RE OBSERVEZLES INSTRUCTIONS SUIVANTES 1 ETOUFFEZ LES FLAMMES l aide d un couvercle le plus herm tique possible une plaque biscuits ou un plateau en m tal puis teignez le br leur ATTENTION de NE PAS VOUS BRULER Si les flammes ne s teignent pas imm diatement SORTEZ ET APPELEZ LES POMPIERS 2 NE PRENEZ JAMAIS EN MAIN UNE POELE OU UNE CASSEROLE QUI A PRIS FEU vous pourriez vous br ler 8 N UTILISEZ PAS D EAU ni de torchons ou de serviettes mouill s vous provoqueriez une violente explosion de vapeur OND Y 15 4 Utilisez un extincteur SEULEMENT LORSQUE A Vous savez qu il s agit d un extincteur de classe ABC et que vous en connaissez le fonctionnement B L incendie est petit et limit l endroit o il a d but C Les pompiers ont t avis s D V
36. ght NON DUCTED HOODS ONLY Note the following material must be purchased separately for non ducted recirculation installations 1 Non Ducted Recirculation Kit RK54 Discard the plastic discharge collar supplied with the hood Install the 5 to 6 adapter supplied with the non ducted recirculation kit over the blower discharge Fig 12 Duct tape alljoints to make them secure and air tight 10 MOUNTING SCREWS 3 9x9 5mm l SUPPORT l FRAME t BRACKET l SUPPORT FRAME FRONT FIG 9 predios ELECTRICAL 7 SE MOUNTING PLATE COLLAR NON DUCTED ONLY PREPARE THE HOOD cont d NON DUCTED HOODS ONLY 3 Install the non ducted recirculation plenum through the upper rectangular openings in the support frame Fig 13 4 Install the 5 diameter duct connector to plenum Twist and lock to secure Fig 14 5 Attach 5 diameter metal expandable duct to the plenum When stretched it must be long enough to reach the bottom of the support frame Fig 14 6 Duct tape all joints to make them secure and air tight NON DUCTED RECIRCULATION PLENUM R 4 ll INSTALL UPPER DECORATIVE FLUE DUCTED HOODS ONLY 8 FOOT AND 9 FOOT CEILINGS 1 Install and secure the upper flue to the support frame with 2 2 9x9 5mm mounting screws Fig 15 e On 8 foot ceilings install with air vents down e On 9 foot ceil
37. he electricity supply before carrying out any operations on the appliance To change bulbs 1 Loosen the ring nut by turning it counterclockwise 2 Remove the bulb by pulling sideward DO NOT ROTATE A CAUTION Bulb may be hot 3 Replace with Type T3 12Volt 20 Watt Max G 4 Base halogen bulb Do not touch FIG 2 replacement bulb with bare hands Do not use bulbs greater then 20 Watts Bulbs greater than 20 Watts will cause fuse to open 4 FUSE REPLACEMENT IF LIGHTS FAIL TO OPERATE DISCONNECT THE POWER AT THE SERVICE ENTRANCE CHECK THE FUSE AND REPLACE IF NECESSARY 1 2 Remove the grease filters Remove the cover of the fuse box 3 Locate the fuse holder Unscrew its cap and remove the fuse Replace the fuse with the same size and amperage 5x20mm 4amp 125volt Do not use fuses greater than 4 amps Fuses greater than 4 amps may damage the transformer Reinstall the fuse holder cap fuse box cover and grease filters Reconnect power at the service entrance FUSE BOX FIG 3 MAINTENANCE Proper maintenance of the Range Hood will assure proper performance of the unit Grease Filter The grease filter should be cleaned frequently Use a warm detergent solution Grease filter is dishwasher safe See INSTALL FILTERS section for removal and installation instructions Non ducted Recirculation Filter The non ducted recirculation filter should b
38. ice la chimenea inferior hacia arriba y sobre la chimenea superior hasta que toque el techo Sujete ambas mitades entre ellas provisionalmente con cinta para conductos Fig 17 INSTALACI N DE LA CAMPANA A PRECAUCION Dados el peso y el tama o de la campana se necesitan dos instaladores como minimo 1 Fije la campana al armaz n de soporte con seis tornillos de montaje de 3 9 x 9 5 mm y dos arandelas onduladas Fig 18 38 TORNILLOS DE MONTAJE 2 9x9 5mm CHIMENEA SUPERIOR CHIMENEA INFERIOR CINTA ADHESIVA y ARANDELAS DENTADAS TORNILLOS DE MONTAJE 3 9x9 5mm FIG 18 CONEXION DE LA TUBERIA CONEXION CON Encinte todas las conexiones para CONDUCTOSDE fijarlas y estanqueizarlas SOLO PARA CAMPANAS CON CONDUCTO 1 Conecte el conducto met lico de 6 de di metro a la tuber a que descarga al exterior SOLO PARA CAMPANAS SIN CONDUCTO 2 Conecte el conducto met lico expansible de 5 entre el pleno y el Z adaptador de la descarga del soplador CONEXION CON CAMPANAS CON O SIN CONDUCTO CONDUCTOS DE5 FIG 19 3 Retire la cinta de la chimenea inferior Baje la chimenea hasta que se asiente en la parte superior de la campana 4 Quite la cinta adhesiva de la chimenea superior y inferior Baje la chimenea hasta que se asiente en la parte superior de la campana INSTALACION ELECTRICA A ATENCION El cableado el ctrico deben realizarlo
39. ido o de las vetas del remate del inoxidable No apriete demasiado porque podr a da ar la superficie e No deje que las manchas se acumulen durante mucho tiempo e No use utensilios o cepillos de acero Peque as particulas de acero pueden adherirse y oxidarse e No use soluciones salinas desinfectantes lej as o productos de limpieza que permanezcan en contacto con el acero inoxidable durante largos periodos de tiempo Muchos de estos productos contienen componentes qu micos que podr an 30 2 PREPARE LA CAMPANA Sacar la campana de l embalaje y controlar el contenido Recivireis 1 Campana 1 Chimenea decorativa 1 Armaz n de soporte 1 Bolsita con 1 Placa armaz n de soporte 1 Casquillo 4 Tirafonds 6 x 70mm 14 Tornillos de montaje 3 9 x 9 5mm cabeza redonda 2 Tornillos de montaje 2 9 x 9 5mm cabeza redonda 4 Arandelas D 6 4mm 6 Arandelas dentadas 1 Cubierta de la caja del cableado 1 Sujeta cabo 1 Instrucciones para instalaci n CASQUILLO PLACA ARMAZ N DE SOPORTE SUJETA CABO gt ee ot DE LA DEL CABLEADO 4 TIRAFONDS 6 x 70mm EE CHIMENEA ARMAZON DE DECORATIVA SOPORTE 14 TORNILLOS DE MONTAJE 3 9 x 9 5mm cabeza plano gt Q 4 ARANDELAS 6 ARANDELAS 2 TORNILLOS D 6 4mm DENTADAS DE MONTAJE 2 9 x 9 5mm cabeza plano 33 INSTALACION DEL TUBO DE EXTRACCION CAMPANAS CONCONDUCT
40. ings install upper flue with air vents up 10 FOOT CEILINGS 2 Discard the upper flue supplied with the hood Replace with the upper flue supplied with flue extension model FX54SS 3 Install and secure the upper flue to the support frame with 2 2 9x9 5mm mounting screws 11 DUCT CONNECTOR 5 METAL EXPANSION FIG 14 MOUNTING SCREWS 2 9x9 5mm DS VENTS UP VENTS DOWN FIG 15 INSTALL THE UPPER DECORATIVE FLUE cont d NON DUCTED HOODS ONLY 8 FOOT AND 9 FOOT CEILINGS 4 Install the upper flue with air vent up Secure to the support frame with 2 2 9x9 5mm mounting screws Fig 16 10 FOOT CEILINGS 5 Discard the upper flue supplied with the hood Replace with the upper flue supplied with flue extension model FXN54SS 6 Install with air vents up and secure to the support frame with 2 2 9x9 5mm mounting screws INSTALL LOWER DECORATIVE FLUE 1 Slide the lower flue up and over the upper flue until it contacts the ceiling Temporarily secure the both halves together with duct tape Fig 17 INSTALL THE HOOD A CAUTION At least two installers are required due to the weight and size of the hood 1 Secure the hood to the support frame with 6 3 9x9 5mm mounting screws and 2 serrated washers Fig 18 HIDE MOUNTING SCREWS 2 9x9 5mm FIG 16 LOWER FLUE TAPE
41. iring into the electrical box Reinstall the wiring box cover Raise the upper flue and reinstall mounting screws gt E LINE IN 120 VOLTS 60 HZ WIRING BOX BLK BLK ca ee y WIRE CLAMP WHT WHT GRN GRN FIG 20 13 INSTALL FILTERS DUCTED AND NON DUCTED HOODS 1 To remove the GREASE filter push in on the metal latch tab and tilt filter downward to remove 2 To install the GREASE filter align rear filter tabs with slots in the hood Depress the metal latch tab push filter into posi tion and release Make sure filter is se curely engaged after installation FILTERS FIG 21 NOTE Prior to use remove protective film from the filter frame sl Siebel HOODS ONLY 1 To remove the CHARCOAL filter push in on the front filter latch Pull the filter down to disengage the rear filter tabs 2 To install the CHARCOAL filter align the rear filter tabs with slots in the hood Push the filter up into place until the front latch snaps securely into the slot Make sure the filter is securely engaged after as sembly 3 Install GREASE filter after charcoal filter is installed NON DUCTED RECIRCULATION FILTER FIG 22 WARRANTY ONE YEAR LIMITED WARRANTY FOR BROAN PRODUCTS Broan NuTone LLC Broan NuTone warrants to the original consumer purchaser of Broan products that such products will be free from defects in materials or workma
42. le mat riel suivant doit tre achet s par ment pour les installations a recirculation e Kit de recirculation RK54 1 Ne pas utiliser le collier d vacuation accompagnant la hotte Installer l adaptateur de 6 po 5 po accompagnant le kit de recirculation sur le conduit d vacuation Fig 12 2 Sceller herm tiquement les joints l aide de ruban conduits 23 VIS DE MONTAGE 3 9 x 9 5 mm e a N BRIDE DE LA STRUCTURE DE SUPPORT STRUCTURE DE SUPPORT DEVANT FIG 9 PLAQUE VIS DE MONTAGE D INSTALLATION 3 9 x 9 5 mm LECTRIQUE FIG 10 VACUATION COLLIER SEULEMENT _ D VACUATION FIG 11 RECIRCULATION SEULEMENT ADAPTATEUR 6 po 5 po e PREPARATION DE LA HOTTE suite HOTTES A RECIRCULATION SEULEMENT 3 Installer le d flecteur a travers les ouvertures rectangulaires dans la structure de support Fig 13 4 Monter le raccord de conduit d un diam tre de 5 po sur le d flecteur Tourner et verrouiller en place Fig 14 5 Fixer le conduit m tallique extensible de 5 po de diam tre sur le d flecteur Une fois tir il doit tre suffisamment long pour atteindre le fond de la structure de support Fig 14 6 Sceller herm tiquement tous les joints l aide de ruban conduits DEFLECTEUR RS S FIG 13 BRIDE
43. na altura m xima de 30 sobre la encimera Si la altura del techo y la longitud de la chimenea lo permiten se puede aplicar una distancia superior a 30 a discreci n del instalador y el usuario b Precisa una extensi n de chimenea adicional de 10 TECHOS DE 10 PIES Nota Para las instalaciones en techos de 10 pies deben adquirirse por separado los materiales siguientes Extensi n de chimenea modelo FX54SS para instalaciones con conducto Extensi n de chimenea modelo FXN54SS para instalaciones sin conducto Deseche la mitad superior del armaz n de soporte suministrada con la campana extractora Sustit yala por el armaz n superior de soporte m s largo suministrado con la campana extractora Siga los pasos 1 a cuatro antes indicados 35 PREPARACION DEL ARMAZON DE SOPORTE cont 7 Cuelgue el armaz n de soporte de la brida para armaz n de soporte situada en el techo Fije firmemente con cuatro tornillos de montaje de 3 9 x 9 5 mm Fig 9 PREPARACI N DE LA CAMPANA CAMPANAS CON O SIN CONDUCTO 1 Monte la Placa del sistema el ctrico a la campana con dos tornillos de montaje de 3 9 x 9 5 mm y dos arandelas dentadas Fig 10 S LO PARA CAMPANAS CON CONDUCTO 2 Monte el casquillo de plastico de descarga en la abertura de descarga del soplador Fig 11 3 Monte el conducto met lico de 6 de di metro sobre la descarga del soplador Debe ser suficientemente largo para llegar a la tuberi
44. ndicados en la garant a 2 Antes de hacer una revisi n o de limpiar la unidad descon ctela de la red para evitar que se encienda de manera accidental En el caso de que ste no pueda ser desacti vado se indicar nel panel de servicio 3 El montaje y la instalaci n el ctrica debe hacerlos un t cnico especializado siguiendo las normas est ndar e incluyendo aquellas de construcci n anti incendio 4 Necesita aire suficiente para una apropiada combusti n y escape de gases a trav s del tubo del dep sito de quema de combustible Para evitar que el humo aspirado vuelva a la cocina siga las directivas del fabricante y las normas est ndar de siguridad as como las normas publicadas por la Asociaci n de prevenci n de incendios NFPA y la Socie dad americana de especialistas en cale facci n refrigeraci n y aire acondicionado y adem s las normas de las autoridades locales Hacer un corte o un taladro en la pared o en el techo no debe da ar la instalaci n el ctrica u otras instalaciones ocultas en la pared Los conductos ventiladores deben siempre desalojar al exterior No use esta unidad con dispositivo de control de la velocidad a estado s lido Para evitar el riesgo de incendio use solamente conductos de metal Esta unidad tiene que ser conectada a tierra oa ARA EVITAR EL RIESGO DE FUEGO POR ALTO NIVEL DE GRASA Nunca abandone los quemadores con el fuego alto La cocci n causa humo y restos de grasa que pue
45. nship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCAN DESCENT BULBS FUSE FILTERS DUCTS ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCT ING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or instal lation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or con
46. ous pouvez combattre l incendie en ayant acc s une sortie de secours Tir es du Kitchen Fire Safety Tips publi par la NFPA ATTENTION 1 Pour usage int rieur seulement 2 Afin de r duire les risques d incendie et d vacuer correctement l air assurez vous d vacuer l air lext rieur N vacuez pas l air dans des espaces clos comme l int rieur des murs ou d un plafond dans le grenier faux plafond ou garage Faites tr s attention lors de l utilisation de produits de nettoyage ou de d tergents Evitez d utiliser des aliments pouvant s enflammer sous la hotte de cuisini re N utilisez cet appareil que pour une ventilation g n rale Ne Putilisez pas pour vacuer des mati res ou des vapeurs dangereuses ou explosives 6 Pour viter de causer des dommages au moteur et de rendre les rotors bruyants et ou non quilibr s gardez votre appareil l abri des poussi res de gypse et de construction ou de r novation etc 7 Le moteur de votre hotte poss de une protection thermique qui teindra automatiquement le moteur s il devient surchauff Il red marrera automatiquement une fois refroidi Si le moteur continue s teindre et se remettre en marche faites v rifier votre hotte 8 Pour une meilleure vacuation des odeurs de cuisson le bas de votre hotte devrait tre aun minimum de 24 po et un maximum de 30 po au dessus de la surface de cuisson Voir Pr paration de la structure de support
47. rmaz n de soporte inferior B08092233 Armaz n de soporte superior B032920200 Sujeta cabos B03294781 Caja de instalaci n el ctrica BO8086668 Base para instalaci n el ctrica BE3344096 Placa interior BE3404365 Soporte B02300729 Trasformador B08086279 Base de los mandos B03295072 Caja de los mandos B03295074 Interruptor del aspirador B03201014 Piloto B03295075 Tapa de la caja mandos B03295073 Interruptor da luz B03295035 Caja fusible BE3404172 Placa BE3404174 Tapa BE3344985 Soporte convoyador BE3343984 Abrazadera B02300789 Caja de la l mpara hal gena B03294776 Tapa protecci n trasformador B080810768 Accesorios para el montaje B06108718 Conjunto mandos Incluye los N 234 228 241 238 229 230 B06002126 Conjunto motor Incluye los N 45 48 49 53 B02300782 Fusible B02300674 Portafusible Se encuentran por separado 43 SERVICE PARTS LISTE DES PIECES DE RECHANGE LISTA DE PIEZAS DE RECAMBIO MODEL E54000 115 116 63 N O co El JUSTA b 04307632 7
48. seguro hacia abajo coloque el filtro en su posici n y su ltelo Aseg rese de que el filtro encaja FILTROS ANTIGRASA FIG 21 correctamente despu s de montarlo NOTA Antes del funcionamiento retire la pelicula protectora del filtro antigrasa naci n SIN CONDUCTO Para quitar el filtro de CARB N empuje la leng eta delantera del filtro Tire del filtro para desconectarlo de las leng etas posteriores 2 Para instalar el filtro de CARBON alinee las leng etas posteriores del filtro con las ranuras de la campana Empujando coloque el filtro en su lugar hasta que el RETEN seguro delantero encaje correctamente en su ranura Asegurese de que el filtro FILTRO AL encaja correctamente despu s de CARBON montarlo FIG 22 3 Instale el filtro de GRASA despu s de instalar el filtro de carb n GARANTIA GARANTIA BROAN POR UN A O Broan NuTone LLC Broan NuTone garantiza al consumidor comprador de sus productos BROAN que dichos productos no tendr n defectos en los materiales o fabricaci n durante un periodo de un a o a partir de la fecha de la compra NO HAY OTRO TIPO DE GARANTIAS QUE INCLUYAN O SE LIMITEN EXCLUSIVAMENTE A GARANTIAS IMPLICITAS O DE CAPACIDAD COMERCIAL O CONVENIENCIA PARA UN PROPOSITO ESPECIFICO Durante el periodo de un a o Broan NuTone si lo estima conveniente reparar o reemplazar sin gastos para el usuario cualquier producto o parte de ste que sea defectuo
49. sequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address stated below or telephone number stated below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date In USA Broan 926 W State Street Hartford WI 53027 800 558 1711 In Canada Broan 550 Lemire Blvd Drummondville QC J2C 7W9 866 737 7770 www Broan com LISEZ ET CONSERVEZ CES INSTRUCTIONS POUR UTILISATION DOMESTIQUE SEULEMENT A AVERTISSEMENT POUR REDUIRE LES RISQUES D INCENDIE D ELECTROCUTION OU DE BLESSURES CORPORELLES OBSERVEZ LES INSTRUCTIONS SUIVANTES 1 N utilisez cet appareil que de la fa on pr vue par le manufacturier Si vous avez des questions contactez le manufacturier l adresse ou au num ro de t l phone indiqu s dans la garantie 2 Avantde nettoyer ou de r parer appareil coupez le courant au panneau d alimentation et verrouillez en l acc s afin d viter sa remise en marche accidentelle Si le panneau d alimentation ne peut tre verrouill apposez un avertissement bien en vidence par exemple une tiq
50. sible parar el ventilador con los interruptores Si usted para la campana halago a partir del panel el ctrico principal LAMPARAS HALOGENAS Este tipo de campana necesita 4 l mparas hal genas Tipo T3 12Volt 20 Watt Max G 4 Base AVERTENCIA Antes de proceder a cualquier operaci n es necesario desco nectar el aparato Para cambiar las l mparas 1 Destornillar la abrazadera en sentido antihorario 2 Extraiga la l mpara oblicuamente NO LA GIRE ATENCI N las lamparas pueden estar calientes 3 Sustituir con l mparas del mismo tipo T3 12Volt 20 Watt Max G 4 Base No toque FIG 2 la lampara de repuesto con las manos desnudas No utilice los bulbos mayor de 20 vatios Los bulbos mayor de 20 vatios haran el fusible abrirse 30 SUSTITUCION DEL FUSIBLE SI LAS LUCES NO FUNCIONAN DESCONECTE LA ELECTRICIDAD EN LA ENTRADA DE SERVICIO COMPRUEBE EL FUSIBLE Y SI FUESE NECESARIO SUSITITUYALO 1 Retire los filtros antigrasa 2 Retire la cubierta de la caja fusible 3 Localice el soporte del fusible CAJA DEL Desatornille su tapa y retire el fusible FUSIBLE 4 Sustituya el fusible por otro del mismo tama o y amperaje 5 x 20 mm 4 amp 125 volt No utilice los fusibles mayor de 4 amperios Los fusibles mayor de 4 amperios pueden da ar el transformador 5 Vuelva a colocar la tapa del portafusibles la cubierta de la caja fusible
51. sos habi ndose usado correctamente ESTA GARANTIA NO CUBRE ESTARTER DE NEON NEON L MPARAS HALOGENAS L MPARAS DE ILUMINACI N FUSIBLE FILTROS CONDUCTOS TAPAS DE TECHO TAPAS DE PARED Y OTROS ACCESORIOS PARA LOS CONDUCTOS Tampoco cubre el mantenimiento ni los productos o partes de stos que hayan sido usados de forma incorrecta con negligencia rotos accidentalmente o por una incorrecta manutenci n reparaci n distinta da la realizada por Broan NuTone montaje incorrecto instalaci n que no se ajuste a las instrucciones de montaje indicadas Le duraci n de la garant a se limita al periodo de un a o como est especificado en la garant a explicita Algunos paises no permiten un limite en la duraci n de la garant a implicita si es asi en su caso esta limitaci n arriba indicada podr a no aplicarse LA PRESENTE GARANTIA CUBRIRA EXCLUSIVAMENTE AL COMPRADOR LOS SERVICIOS DESCRITOS ANTERIORMENTE BROAN NUTONE NO SE HACE RESPONSABLE DE DANOS PRODUCIDOS DE MANERA ACCIDENTAL O RELACIONADOS CON EL USO INCORRECTO DEL PRODUCTO O SU FUNCIONAMIENTO Algunos paises no permiten la exclusi n o limitaci n de los da os producidos de manera accidental si es as en su caso esta limitaci n arriba indicada podr a no aplicarse Esta garant a le da derechos legales espec ficos y podr a tambi n disponer de otros derechos que varian de pa s a pa s Esta garant a supera otras garant as dadas con anterioridad Para disfrutar de la garant a ust
52. uette de couleur vive 3 Les travaux d installation et de raccordement lectrique doivent tre effectu s par du personnel qualifi en respectant les normes et r glements en vigueur y compris les normes et codes de b timent en mati re de pr vention d incendie 4 Une circulation d air efficace est requise afin d assurer la combustion et l vacuation compl te des gaz par la chemin e des quipements combustion pour pr venir les retours de chemin e Conformez vous aux instructions et aux standards de s curit des manufacturiers d quipement de chauffage tels qu ils sont publi s par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE ainsi que les responsables des codeslocaux Lorsque vous coupez ou perforez un mur ou un plafond prenez garde de ne pas endommager les fils lectriques ou autre installation qui pourraient y tre dissimul s Les conduits de l installation doivent toujours vacuer l air l ext rieur N utilisez pas cet appareil avec une autre commande de vitesse semi conducteur Afin de r duire les risques d incendie n utilisez que des conduits en m tal Cet appareil doit tre reli une mise la terre AFIN DE R DUIRE LES RISQUES DE FEU DE CUISINI RE A Ne laissez jamais les appareils de cuisson sans surveillance lorsqu ils sont r gl s feu vif Les d bordements engendrent de la fum e et d
53. y los filtros antigrasa 6 Vuelva a conectar la electricidad en la entrada de servicio 31 MANTENIMIENTO Un mantenimiento adecuado de la campana asegura el funcionamiento correcto del aparato Filtro antigrasa El filtro antigrasa debe limpiarse con frecuencia Use un detergente que no sea fuerte Use un detergente que no sea fuerte El filtro antigrasa se puede meter en el lavavajillas Las instrucciones de desmontaje e instalaci n se encuentran en la secci n INSTALACI N DE LOS FILTROS Filtro al carb n configuraci n sin tubo El filtro al carb n debe cambiarse cada seis meses Las instrucciones de desmontaje e instalaci n se encuentran en la secci n INSTALACION DE LOS FILTROS Limpieza de la campana El acero inoxidable es uno de los meteriales m s f ciles de limpiar pero ser a aconsejable un especial cuidado en su uso para mantenerla en buen estado La campana se puede limpiar de las siguientes maneras e Agua caliente con jab n o detergente es la mejor manera para limpiarla e Acl rela con agua corriente s quela con un pa o suave y limpio para evitar las huellas que deja el agua e Para las manchas o restos de grasa que persistan use un producto qu mico dom stico que no raye un limpiador para acero inoxidable con poca agua y un pa o suave e Si las manchas persisten use un estropajo y un cepillo de cerdas suaves con un producto limpiador y agua Frote suavemente en el sentido del pul

Download Pdf Manuals

image

Related Search

Related Contents

Instrucción Técnica para trabajos con  Manuel d`installation    Hiper ATX v2.2 Active PFC Sli Ready 530W  LTPDA Introduction, NPL, 9th August 2010  Sony Xplod XR-CA330 User's Manual  文書 1 - 東京ガス  ASUS K200MA PG8798 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file