Home

Bradford-White Corp EF-100T-199 User's Manual

image

Contents

1. PROPANE GAS Includes Installed T amp P Valve and Electronic Ignition Model Input 1ST Hour Recovery GPH Stg Therm A B C D E F G H Water Gas Relief Approx Number Delivery at Degree Rise Capacity Eff Floor toj Jacket HW Cold Floor to Floor to Floor to Floor to Conn Conn Valve Shipping at 100 F Top of Dia Out In Gas Vent Air T amp P Dia Dia Open Weight Rise u Heater Conn Outlet Intake Conn BTU Gal 40 F 100 F 140 F Gal in in in in in in in in in in in Ibs Vj e EF 60T 125E 3N A 125 000 187 364 145 104 60 96 0 57 281 4 42 13 53t 5 521 2 40 11 2 3 4 3 4 570 V x EF 60T 150E 3N A 150 000 211 423 169 121 60 93 0 57 281 4 42 13 5831 2 5 521 2 40 11 2 3 4 3 4 570 V x EF 60T 199E 3N A 199 999 265 558 223 159 60 92 0 SY 2814 42 13 5312 5 521 2 40 11 2 3 4 3 4 570 V EF 100T 150E 3N A 150 000 250 450 180 129 100 99 1 775 s 281 4 63 13 743 4 5 731 8 60 11 2 3 4 3 4 900 V x EF 100T 199E 3N A 199 999 309 597 239 171 100 98 5 775 281 4 63 13 743 4 5 731 8 60 11 2 3 4 3 4 900 V x EF 100T 250E 3N A 250 000 364 735 294 210 100 97 0 775 s 281 4 63 13 7483 4 5 731 8 60 11 2 3 4 1 900 V x EF 100T 300E 3N A 300 000
2. special dielectric fittings to buy eF Series Optional Equipment Features Maxitrol Gas Pressure Regulating valve Ensures proper supply pressure to eF unit of 7 to 11 W C provided incoming pressure is between 1 2 and 2 psi This can be ordered as a separate part or as part of the heater For the separate part please use p n 243 45517 00 not available for use with the EF 100T 399 Concentric Vent Terminal Kit 3 termination fitting provides for only one exit opening through wall or roof p n 239 44069 01 NSF Compliance Kit p n 265 44542 04 Exhaust Flexible Venting The eF Series can vent vertically or horizontally with either 3 or 4 PVC CPVC or ABS vent pipe and is approved for direct vent closed combustion applications or those applications that require inside air for combustion Foam Core pipe is permitted on the entire venting system The eF Series is also approved for unbalanced venting which means the air intake pipe doesn t have to be vented the same distance as the exhaust NOTE Air intake cannot exceed exhaust by more than 30 feet Model Max 3 PVC Max 4 PVC Number ABS amp CPVC ABS amp CPVC EF 60T 125 120 ft 170 ft EF 60T 150 100 ft 150 ft EF 60T 199 80 ft 130 ft EF 100T 150 170 ft EF 100T 199 150 ft EF 100T 250 130 ft EF 100T 300 110 ft EF 100T 399 50 ft 100 ft Determining required vent length 1 Determine the total length of straigh
3. 405 836 335 239 100 92 0 775 281 4 63 13 743 4 5 731 8 60 11 2 3 4 1 900 V EF 100T 399E 3N A 399 999 521 1127 451 322 100 93 0 775 s 281 4 63 13 73 4 5 731 8 60 112 1 1 950 Model Input 1ST Hour Recovery LPH Stg Therm A B c D E F H Water Gas Relief Approx Number Delivery at Degree Rise Capacity Eff Floor to Jacket HW Cold Floor to Floor to Floor to Floor to Conn Conn Valve Shipping at 56 C Top of Dia Out In Gas Vent Air T amp P Dia Dia Open Weight Rise Heater Conn Outlet Intake Conn kW Liters 22 C 56 C 78 C Liters mm mm mm mm mm mm mm mm mm mm mm kgs V x EF 60T 125E 3N A 36 6 708 1378 545 394 227 96 0 1448 718 1067 330 1359 128 1324 994 38 19 19 259 Vj EF 60T 150E 3N A 43 9 799 1601 640 458 227 93 0 1448 718 1067 330 1359 128 1324 994 38 19 19 259 Vj EF 60T 199E 3N A 58 6 1003 3112 844 602 227 92 0 1448 718 1067 330 1359 128 1324 994 38 19 19 259 V EF 100T 150E 3N A 43 9 946 1703 681 488 379 99 1 1972 718 1600 330 1899 128 1857 1527 38 19 19 408 V x EF 100T 199E 3N A 58 6 1170 2260 905 647 379 98 5 1972 718 1600 330 1899 128 1857 1527 38 19 19 408 V EF 100T 250E 3N A 73 2 1378 2782 1113 795 379 97 0 1972 718 1600 330 1899 128 1857 1527 38 19 25 408 V EF 100T 300E 3N A
4. 87 9 1533 3165 1268 905 379 92 0 1972 718 1600 330 1899 128 1857 1527 36 19 25 408 V x EF 100T 399E 3N A 117 2 1972 4266 1707 1219 379 93 0 1972 718 1600 330 1861 128 1857 1524 38 25 25 431 For propane gas models change suffix N to X and remove E from the model number Note The weight is the same for both ASME and Non ASME models Example EF 1001 150 3X NSF Construction Available with optional kit v TIS A C Peguirad Complies with SCAQMD low NOx requirements 10 39 ng joule e Electronic Ignition Listed with California Energy Commission A ASME All models are available with ASME construction To order ASME construction add the A to the end of the model number Example EF 60T 125E 3NA Design certified by CSA International formerly AGA CGA Amp Draw range 1 0 to 1 8 amps and 7 0 amps for EF 100T 399 150 PSI Working Pressure 1034 kPa 300 PSI Test Pressure 2068 kPa Ultra High Efficiency Water Heaters mammum All models are design certified by CSA International formerly AGA CGA for up to 180 F 82 C application as an Automatic Storage Heater and an Automatic Circulating Tank Heater As an Automatic Storage Heater all models are complete self contained water heating systems It needs no separate storage tank pump wiring or elaborate piping network When equipped with a mixing valve it will supply 180 F 82 C sanitizing and 140 F 60 C general purp
5. S BRADFORD WHITE mmm C O R PO R A TIO N 800 B 1006 A Commercial Gas Ultra High Efficiency Water Heater The Ultra High Efficiency Water Heater Models Feature veer E Thermal Efficiency Up To 99 1 m 60 Gallon Tank Capacity in 125 000 150 000 and 199 999 a BTU hr Inputs 100 Gallon Tank Capacity in 150 000 199 999 250 000 300 000 and 399 999 BTU hr Inputs Flexible Venting Conventional Through the Wall or Direct Vent Three Pass Flue System Low NOx Premix Power Burner Ultra Quiet Operation Submerged Combustion Chamber 1 NPT Side Connection For Hydronic Applications Electronic Controls Zero Inch Clearance To Combustibles Vitraglas Lined Tank Four Protective Magnesium Anode Rods except EF 100T 399 Powered Anode Rods only EF 100T 399 Hand Hole Cleanout Allows inspection of tank interior Factory Installed Hydrojet Sediment Reduction System Factory Installed Dielectric Fittings Non CFC Foam Insulation 3 Optional Concentric Vent Kit ASME Construction Available NSF Construction Available With Optional Kit Brass Drain Valve T amp P Relief Valve Factory Installed Three Year Limited Warranty On Steel Tank One Year Limited Warranty On Parts gt Photo is of EF 100T 199 3 or 5 Year Limited Tank Warranties 1 Year Limited Warranty on Component Parts For more information on warranty please visit www bradfordwhite com For products installed in USA Canada and Puer
6. ceeds California emission requirements Submerged Combustion Chamber Submerging the combustion chamber in the center of the water storage tank minimizes radiant heat loss and improves efficiency Non CFC Foam Insulation Surrounds the tank surface saving energy by retarding loss of heat Electronic Controls Adjustable electronic thermostat for control between 80 F and 180 F The recycling Energy Cut Off ECO shuts off all gas flow in an event of an overheat condition Zero Inch Clearance The eFSeries jacket is cool to the touch and is approved for zero inch clearance to combustibles for unsurpassed installation flexibility Vitraglas Lined Tank Bradford White s water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramic porcelain like coating Our high silica Vitraglas lining provides a tough interior surface for Bradford White s water heater tanks Protective Magnesium Anode Rods Employed to provide an extra measure of corrosion protection for longer life Each eF heater has 4 anodes except the EF 100T 399 which has 2 powered anode rods and one non powered anode rod Factory Installed Hydrojet Sediment Reduction System Cold inlet sediment reduction device made of stainless steel for increased durability Helps prevent sediment build up in tank Factory Installed Dielectric Fittings All heaters equipped with special water heater nipples for longer heater life No
7. o 180 F 82 C A recycling Energy Cut Off E C O shuts off all gas in the event of an overheat condition The entire installation shall be made in compliance with state and local codes and ordinances Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement SS BRADFORD WHITE C O R POR ATI ON Ambler PA For U S and Canada field service contact your professional installer or local Bradford White sales representative Sales 800 523 2931 Fax 215 641 1670 Technical Support 800 334 3393 e Fax 269 795 1089 e Warranty 800 531 2111 Fax 269 795 1089 International Telephone 215 641 9400 e Telefax 215 641 9750 Fax on Demand 888 538 7833 www bradfordwhite com bas a BRADFORD WHITE CANADA INC Sales Technical Support 866 690 0961 905 238 0100 Fax 905 238 0105 www bradfordwhitecanada com Count On Bradford White For Everything Hot Water 2006 Bradford White Corporation All rights reserved 800 B 1006 A Printed in U S A
8. ose hot water simultaneously These models can be used either as a single unit or as multiples connected in parallel Sample Specification The water heater shall be a Bradford White model EF with a rated storage capacity of not less than gallons liters a minimum gas input of BTU hr a minimum recovery of GPH LPH at 100 F 56 C temperature rise and a Thermal Efficiency Rating of ___ It shall be design certified by CSA International formerly AGA and CGA for 180 F 82 C application either with or without a separate storage tank The tank shall be lined with Vitraglas vitreous enamel and shall have a bolted hand hole cleanout The tank shall have four extruded magnesium anode rods installed in separate head couplings up to 300 000 BTU hr input or two powered anode rods and one extruded magnesium anode rod for 399 999 BTU hr input This water heater shall be equipped with stainless steel cold water inlet Hydrojet Sediment Reduction System The heater shall be insulated with Non CFC foam This water heater shall be equipped with an electronic ignition system an ASME rated T amp P relief valve and a premix closed combustion system for direct venting using either 3 76mm or 4 102mm PVC CPVC or ABS vent pipe 115V AC required The water heater shall be factory assembled and tested The water heater shall be approved for zero inch clearance to combustibles The control shall be an adjustable electronic thermostat to any temperature up t
9. t vent pipe in feet required for both the intake and the exhaust 2 Add 5 feet of venting for every 90 elbow 3 Add 2 1 2 feet of venting for every 45 elbow 4 Total vent length cannot exceed Max Length in the above venting table 5 Air intake cannot exceed exhaust by more than 30 feet in any venting situation NOTICE Do not include the 3 exhaust elbow or vent terminals in determining maximum vent length Three year limited warranty on steel tank Heavy gauge steel automatically formed rolled and welded to assure a continuous seam for glass lining One year limited warranty on parts Intake Combustion Air Rain Cap p n 239 44069 01 Ultra High Efficiency Water Heaters mmmn Gas Inlet 8 Exhaust 8 Air Intake T amp P Valve B 28 NPT Gas Inlet T amp P Valve 3 PVC Air Inlet ki B pa 7 i Ii MEI a z 1 NPT z D z Outlet A E 1 NPT Space Heating Outlet G Cleanout 1 NPT Space PVC Cc Heating Return EXHAUST ia A Drain Can D 114 NPT Inlet Ne ZL F ft a a Vy NPT CONDENSATE 3 pyc Exhaust CONNECTION NOTE Diagrams are for both the 60 and 100 gallon models eF Series Commercial Ultra High Efficiency Water Heater Meet or exceed ASHRAE 90 1b current standard C E C Listed NATURAL GAS AND LIQUID
10. to Rico Some states do not allow limitations on warranties See complete copy of the warranty included with the heater MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U S PATENTS 7 063 133 B2 5 954 492 5 954 492 5 761 379 5 943 984 5 081 696 5 988 117 6 142 216 5 199 385 5 574 822 5 372 185 5 485 879 5 277 171 B1 5 341 770 5 660 165 5 596 952 5 682 666 4 904 428 5 023 031 5 000 893 4 669 448 4 829 983 4 808 356 5 115 767 5 092 519 5 052 346 4 416 222 4 628 184 4 861 968 4 672 919 Re 34 534 OTHER U S AND FOREIGN PATENT APPLICATIONS PENDING CURRENT CANADIAN PATENTS 1 272 914 1 280 043 1 289 832 2 045 862 2 112 515 2 108 186 2 107 012 2 092 105 Vitraglas and Hydrojet are registered trademarks of Bradford White Corporation 2006 Bradford White Corporation All rights reserved Printed in U S A Ultra High Efficiency Water Heaters ees eF Series Standard Equipment Features Thermal Efficiency up to 99 1 Fully condensing design Three Pass Flue System The three pass flue system keeps the hot combustion gases moving at a high velocity The combination of high turbulence and velocity causes an enormous rate of heat transfer into the water Low NOx Premix Power Burner Developed for the eFSeries a turbulent flame shoots down the submerged combustion chamber This turbulence causes a thorough mixing of the gas and air for optimum combustion and high heat transfer efficiencies Far ex

Download Pdf Manuals

image

Related Search

Related Contents

Doro PhoneEasy® 618  Un expert en mérite bien un autre !  DW621 DW622  Gpredict User Manual - W1NPP.ORG Home of the Androscoggin  CLUB3D CGAX-43524I 1GB graphics card  Dell W3707C Flat Panel Television User Manual  Mutant Media Ellipse  SERVICE MANUAL MB23 and MB25 Moisture Analyzers  NTC 2769-4 - ICONTEC Internacional  How to Use This Manual  

Copyright © All rights reserved.
Failed to retrieve file