1. 1 en Bosch Security Systems Megapixel IP Cameras Important Safety Instructions Type numbers NWC 0700 NWC 0800 NWC 0900 Read follow and retain all of the following safety instructions Heed all warnings on the unit and in the operating instructions 1 2 10 11 12 13 Clean only with a dry cloth Do not use liquid cleaners or aerosol clean ers Do not install unit near any heat sources such as radiators heaters stoves or other equipment including amplifiers that produce heat Do not block any ventilation openings Do not use the unit near water or expose to rain or moisture Never spill liquid of any kind on the unit Unplug the unit during lightning storms or when unused for long peri ods Adust only those controls specified in the operating instructions Do not overload outlets and extension cords as this can cause fire or electrical shock Protect the plug and power cord from foot traffic or pinching at elec trical outlets and at its exit from the unit Operate the unit only from the type of power source indicated on the label Unless qualified do not attempt to service a damaged unit yourself Refer all servicing to qualified service personnel Use only replacement parts specified by the manufacturer Install in accordance with the manufacturer s instructions in accor dance with applicable local codes Use only attachments accessories specified by the manufacturer Equipment change o
2. devices connected Use Advanced mode if the network has other devices con nected this is because using Automatic mode risks dupli cating existing IP addresses F 01U 032 595 V 1 0 2007 03 Quick Install Guide Bosch Security Systems Megapixel IP Cameras Quick Install Guide en 6 Basic mode 1 Click Automatic The install program will scan the network for all connected MegaPixel cameras and assign an IP address automatically within the network segment of the host PC When all the connected cameras show Success in the Results column the installation process is complete 2 Write down the MAC Ethernet address corresponding IP address and installed location 3 Click Save Exit when done aa BOSCH Camera Installer Language Mode BOSCH Camera Installer Present Cameras Eth ddr Current IP Result Moi ion fi Fig 1 1 Camera installation in basic mode showing results Bosch Security Systems Quick Install Guide F 01U 032 595 V 1 0 2007 03 7 en Bosch Security Systems Megapixel IP Cameras fa End Automatic Language Mode Et et Address Of Camera y Current era Pyh Cards IP 50 c2 3B ep 53 eran 0 pes 00 11 25 25 4C0 98 Result 00 50 C2 3B 6B 14 192 168 0 10 success NWC 0900 62013 00 50 C23B6B 53 192 168 0 11 success NWC 0700 62130 Save Exit Fig 1 2 Camera installation in advanced mode showing results Advanced mode 1 Start making a list of Ethernet MAC addresse
3. 2 VDC units voltage applied to the unit s power input should not exceed 12 3 VDC Bosch Security Systems Quick Install Guide F 01U 032 595 V 1 0 2007 03 5 en Bosch Security Systems Megapixel IP Cameras 1 3 1 3 1 1 3 2 1 Attach camera to the 100 Mbps network input of the PC with the cross link CAT 5 cable 2 Manual iris lens check the lens to make sure the F Stop is between F2 8 and F4 0 3 DC iris lens plug in the DC iris cable into the iris connec tor on the rear of the camera 4 Plug in the camera power cord 5 A yellow LED on the back of the camera should light up after a few seconds This LED indicates that a link to the computer has been established A green LED will blink when the camera is accessed Setting camera IP address The camera is supplied with installation software on CD The installation software assists setting up the camera s IP address To run the installation software 1 Make sure your Windows XP 2K account has administrative privileges 2 Using Windows Explorer navigate to the CD and double click the installer exe file The camera installer program opens Configure firewall As you start the application your PC may prompt you to permit its access to the network Allow the Camera Installer program to access the network Assigning IP addresses Choosing between Basic or Advanced modes Only use Basic mode default if the network does not have other
4. and this device must accept any interference received includ ing interference that may cause undesired operation NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules and ICES 003 of Industry Canada These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and radiates radio frequency energy and if not installed and used in accor dance with the instruction manual may cause harmful interfer ence to radio communications Operation of this equipment ina residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense Intentional or unintentional modifications not expressly approved by the party responsible for compliance shall not be made Any such modifications could void the user s authority to operate the equipment If necessary the user should consult the dealer or an experienced radio television technician for cor rective action The user may find the following booklet prepared by the Federal Communi cations Commission helpful How to Identify and Resolve Radio TV Interfer ence Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 WARNING This is a cl
5. ass A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures F 01U 032 595 V 1 0 2007 03 Quick Install Guide Bosch Security Systems Megapixel IP Cameras Quick Install Guide en 4 1 1 1 Quick Install Guide Camera installation using PoE switch Equipment needed PC with 100baseT or better network port 100 baseT or better network switch with PoE capability 2 CAT5 Network cables as CAUTION Never supply power via the Ethernet connection PoE when power is already supplied via the power connector 1 2 1 Attach camera to a PoE port of the network switch with CAT5 cable 2 Attach non PoE switch port to the PC LAN port with CAT5 cable 3 Manual iris lens Check the lens to make sure the F Stop is between F2 8 and F4 0 4 DcC iris lens Ensure that the DC iris cable is plugged into the iris connector on the rear of the camera 5 Plug in the switch s power cord 6 A yellow LED on the back of the camera should light up after a few seconds This LED indicates that a link to the computer has been established A green LED will blink when the camera is accessed Camera installation with direct connection to PC Equipment needed PC with 100baseT or better network port 1 CAT5 cross linked network cable Power supply unit 9 12 VDC 500 mA A CAUTION For 9 1
6. electrical lights or where it may contact such power lines circuits or lights Operate the unit only from the type of power source indi cated on the label Before proceeding be sure to discon nect the power from the cable to be installed into the unit For external power supplied units use only the rec ommended or approved power supplies For limited power source units this power source must comply with EN60950 Substitutions may dam age the unit or cause fire or shock For 9 12 VDC units voltage applied to the unit s power input should not exceed 12 3 VDC User sup plied wiring must comply with local electrical codes Class 2 power levels Do not ground the supply at the terminals or at the unit s power supply terminals If unsure of the type of power supply to use contact your dealer or local power company NOTICE You can view and print the full version of this Installation Manual with Adobe Acrobat Reader both provided on the enclosed CD ROM This user guide is the intellectual property of Bosch Security Systems protected by copyright Bosch Security Systems Quick Install Guide F 01U 032 595 V 1 0 2007 03 3 en Bosch Security Systems Megapixel IP Cameras FCC amp ICES INFORMATION U S A and Canadian Models Only This device complies with part 15 of the FCC Rules Operation is subject to the following conditions this device may not cause harmful interference
7. r modification could void the user s guarantee or authorization agreement WARNING Medium risk DANGER High risk This symbol indicates an imminently hazardous situation such as Dangerous Voltage inside the product If not avoided this will result in an electrical shock serious bodily injury or death Indicates a potentially hazardous situation If not avoided this could result in serious bodily injury or death gt CAUTION Indicates a potentially hazardous situation If not avoided this may result in minor or moderate injury Alerts the user to important instructions accompanying the unit F 01U 032 595 V 1 0 2007 03 Quick Install Guide Bosch Security Systems Megapixel IP Cameras Quick Install Guide en 2 CAUTION Indicates a potentially hazardous situation If not avoided this may result in property damage or risk of damage to the unit NOTICE This symbol indicates information or a company policy that relates directly or indirectly to the safety of personnel or protection of property CAUTION U S A models only Section 810 of the National Electrical Code ANSI NFPA No 70 provides information regarding proper grounding of the mount and supporting structure location of discharge unit connection to ground elec trodes and requirements for the grounding electrode Power lines do not locate the camera near overhead power lines power circuits
8. s and IP addresses assigned to them The Ethernet address is on the camera label 2 Click Find Cameras Select a camera by clicking its Ethernet address Bp Enter the IP address assigned to that camera in the New Camera IP box Click Set IP Click Automatic Wait for result to change from unchecked to success Click Save Exit when done ai EE Viewing the image 1 Open Internet Explorer 2 Inthe address line enter http IPADDRESS index html 3 Click Video to display the image 4 Adjust the lens for optimal focus NOTICE Adjust back focus if necessary a Loosen the set screws in the top and bottom of the front panel use 1 16 inch hex key F 01U 032 595 V 1 0 2007 03 Quick Install Guide Bosch Security Systems Megapixel IP Cameras Quick Install Guide en 8 b Rotate lens in or out with back focus ring until focus is obtained c Fasten the two set screws Bosch Security Systems Quick Install Guide F 01U 032 595 V 1 0 2007 03
Download Pdf Manuals
Related Search
Related Contents
Samsung Wave Y 水道配水用ポリエチレン管施工特記仕様書(PDF文書) MN–ITS Interactive (837I) Outpatient claim form for Home Care TP-Link TF-3239DL V1 Declaration of Conformity 3/3 Loft Bed 4/6 Loft Bed FGS-2324K - Ruby Tech. Tripp Lite Cat5e 350MHz Molded Cross-over Patch Cable (RJ45 M/M) - Yellow, 10-ft. 2009 Contents Introduction GUIA DO USUÁRIO - Support Copyright © All rights reserved.