Home

Bosch 00P User's Manual

image

Contents

1. LTC9316 00P Security Systems Installation Manual N ll Standard Pole LTC9316 00P Instruction Manual Introduction Table of Contents L TL CRPIO ee ee la E E E E 2 2 UNDAN G oases ce cece ee ee ee 2 NIC ee E oe nets er S SSD Dust 2 LEE INSTALLATION ee ee ee ee ee 3 4 1 WS WT O ee ee en ae E 3 2 2 Install a ee ee SK Se d I PURIS 3 4 3 Mounting THE AutoDome S 4 1 DESCRIPTION The LTC 9316 00P units are 16 foot steel mounting poles for use with Unity Domes AutoDomes and the LTC 9320 Series of Outdoor Fixed Domes 2 UNPACKING Unpack carefully This is mechanical equipment and should be handled with care Check for the following Packet Assembly for LTC 9316 00P 1 Bosch Adapter Plate 4 3 8 x l in Stainless Steel Hex Head Bolt 4 5 16 18 Stainless Steel Hex Nut 4 5 16 Stainless Steel Flat Wash 4 3 8 Stainless Steel Split Lockwasher 4 5 16 Stainless Steel Split Lockwasher 1 Wiring grommet Conduit plug 1 Installation Instructions This Manual Steel Pole If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper If any items are missing notify your Bosch Security Systems Sales Representative or Customer Service The shipping carton is the safest container in which the unit may be transported Save it for possible future use 3 SERVICE If the unit ever needs repair service the customer sh
2. apter plate with the holes on the mounting plate at the top of the pole Figure 9 Figure 6 Connecting Wiring Through Pole 5 Slowly lift the pole into the upright position aligning the holes of the Base Plate with the Bolts in the concrete pad FigurBosch Security Systems10 October 2003e 7 Bosch Security Systems 10 October 2003 Adapter Plate Figure 9 Aligning Adapter Plate with Mounting Plate 2 Attach the LTC 9540 xx Wall Bracket adapter plate using the provided hex head nuts and bolts flat washers and lockwashers see Figure 10 Lockwashers Flat W ashers 5 16 18 N uts Figure 10 Attaching the Adapter Plate 3 Attach the LTC 9540 xx Wall Bracket to the adapter plate using recommended 8 mm 5 16 inch bolts studs refer to the LTC 9540 xx Installation Instructions Bolts should be secured with nuts washers and lockwashers Mount the LTC 9540 xx W all Bracket Using These Holes Figure 11 Mounting the LTC 9540 xx W all Bracket 5 SPARE PARTS Part No Description LIC9316AP LTC 9540 xx Wall Arm Adapter Plate Bosch Security Systems Inc Robert Bosch GmbH Bosch Security Systems B V 850 Greenfield Road Gesch ftsbereich P O Box 80002 Lancaster PA 17601 EE UU Postfach 10 60 50 5600 JB Eindhoven Tel 800 326 3270 70049 Stuttgart The Netherlands Fax 1 717 735 6560 Telefax 07 11 811 12 34 Tele 31 40 27 80000 www boschsecuritysystems com 2005 Bosch Security Systems G
3. e thoroughly before proceeding with the installation Figure 4 View of Concrete Foundation 4 2 Installation I NOTE Be sure that the pole is oriented properly with the carriage I Place the pole on the pad with the holes on the Base Plate aligned with the bolts of the anchor bolts or anchor jig Figure 5 2 Remove the access opening plates at the bottom and top LTC9316 00P Instruction Manual Installation EN Access opening plates A D 2 o 2 Bolts or anchor jig Figure 7 Lifting the Pole into Position CAUTION Pull all slack in the wiring as you lift the pole into position to keep from pinching and possible damage Figure 5 Placement of Pole on Pad 6 Ensure that the pole is vertical on all sides Use a bubble level or plumb bob to check 3 Insert the wiring into the 3 diameter hole in the base of the pole Be sure all slack is pulled completely through 7 Secure the pole to the pad with fasteners Figure 8 4 Insert connecting wiring into the bottom access opening run through the pole up to the top access opening Insert the end rough the housing connecting hole Close the top access opening and make necessary wiring connections at the bottom access opening Figure 6 Nut Lock Washer H Flat Washer Figure 8 Securing the Pole to the Pad Top access opening 4 3 Mounting the AutoDome 1 Align the holes of the AutoDome ad
4. mbH 3935 890 38012 28 June Data subject to change without notice
5. ould contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions Service Centers U S A Phone 800 366 2283 or 408 956 3895 fax 800 366 1329 or 408 956 3896 e mail NationalServiceCenter ca slr com Canada 514 738 2434 Europe Middle East amp Asia Pacific Regions 32 1 440 0711 For additional information see www boschsecuritysystems com 4 INSTALLATION This installation should be made by qualified service personnel and conform to the National Electrical Code and applicable local codes 4 1 A l Please read these instructions carefully before proceeding and A N heed all cautions Site Preparation NOTE Special attention must be paid to the size of the wiring conduit and its location within the concrete foundation and jig if applicable The Wiring Conduit can be up to 2 in diameter Use reducers if necessary Also make sure that the Wiring Conduit 1s in the center of the foundation and Anchor Jig during installation Figure 1 Up to 2 inch in Diameter Mounting N x Z 2 d a n A Wiring Pd Conduit _ p Pd l l l l l Figure 1 Mounting Bolts amp Wiring Conduit Location Select a suitable site for the LTC 9316 00P and prepare the pad site using a hole 36 x 36 x 36 deep The top of the concrete foundation should be flush with the gr
6. ound CAUTION Be sure that there are no underground electric or phone cables or gas or water lines in the area where the pole will be located 2 To help reinforce the concrete foundation place 12 1 2 diameter x 32 long Reinforcement Bars rebar as shown in Figure 2 Use suitable preparation methods to place the rebar Bosch Security Systems 10 October 2003 LTC9316 00P Instruction Manual Installation n amir PEEL r m Reinforcement bars 12 Figure 2 Reinforcement Bars 3 FORANCHOR BOLT INSTALLATIONS Pour concrete per manufacturer s directions making sure that the wiring conduit is in the center of the pad See Figure 3 next page for dimensions of the bolt pattern and suspend appropriate bolts in the concrete around the wiring conduit Leave 2 to 3 of the Bolts protruding above the pad If you are using leveling nuts leave 4 to 6 protruding Bosch Security Systems 10 October 2003 4X O 1 000 BASED ON A 11 00 B C 13 0007 778 Be ren E 4 000 HFE O 11 000 Seen et l I Ed 9 4 000 13 000 t Figure 3 Anchor Bolt Dimensions NOTE Prepare the concrete per manufacturer s directions The concrete must have a compressive strength of 3000 psi and must be fabricated following ACI318 89 requirements Allow the concrete foundation to cur

Download Pdf Manuals

image

Related Search

Related Contents

Consulter / Télécharger Postéo numéro 24  廃棄物再生事業者登録申請書  SMSC USB2250 User's Manual  Applica GRP0004B barbecue  APRES LA CATA DES DROITS RECHARGEABLES, LA - CIP-IDF  MCUEZPE05 User Guide - Freescale Semiconductor  Owner`s Manual - Drinkstuff.com  SleepOneBilevel ST User Manual  Samsung GT-S3650C 用户手册  Panasonic Toughbook CF-U1 16GB Black, Silver, White  

Copyright © All rights reserved.
Failed to retrieve file