Home

Bosch V1.0 User's Manual

image

Contents

1. 7 2 Wall Control Panel DIP switch settings The wall control panel is designed to control either the back ground music inputs or the mic line inputs in one specific zone As such each wall control panel requires an ID to let the DSP matrix mixer know which unit or zone is requesting a change in source or volume This is done via DIP IDs switches to allocate a number to the unit and its function The DIP switches are located on the backside of the wall control panel There are two sets of IDs that give the wall control panel different functions 1 DIP IDs 1 8 Line input background music BGM source selection corresponding to output zones 1 8 2 DIP IDs 9 16 Mic line input select and mic line mix mode for output zones 1 8 e g ID 9 Zone 1 ID 16 Zone 8 Wall control panel number ID Line input BGM source selection Mic line mix mode DIP switch 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF JON OFF ON 2 OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF JON ON 3 OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON 4 OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON Factory default Notice A DIP switch in the down position is OFF A DIP switch in the up position is ON Example If all DIP Switches are down OFF this is ID 1 Facto
2. Caution Be sure that the higher voltage does not create a problem for the speakers used If any problem exists this may be solved with the use of a 2 1 step down transformer Bosch Security Systems B V Operation manual 2013 06 V1 0 32 en Operation 8 PLENA matrix Operation Call stations and wall control panels can only operate when connected to the DSP matrix mixer and individual IDs have been set via the DIP switches on the units Refer to Call Station DIP switch settings page 23 and Wall Control Panel DIP switch settings page 24 The multi channel DSP amplifier can operate both as a standalone amplifier or connected to the DSP matrix mixer 8 1 Start 1 Check that all connections have been made to relevant units in the system including wall control panels and call stations 2 Power on the DSP matrix mixer followed by the amplifiers 3 Check that the power LED are illuminated on the front of the DSP matrix mixer and amplifier s 19 rack unit s 4 Check that the RS485 LED is flashing for connections to the wall control panels and call stations 5 Make sure that the level controls on the rear of the amplifier are set to the desired level 6 For use with the PC GUI software Click Device from the menu bar and then Connect Refer to PC GUI software page 16 Ifthe above steps have been followed the system should be in its last mode of operation However if this is the initial p
3. Silver RAL 9006 Weight Approx 6 kg Approx 13 23 Ib 11 2 2 Multi Channel DSP Amplifier Dimensions H x W x D 90 x 440 x 417 mm 3 5 x 17 3 x 16 4 in 19 wide 2RU high Mounting Stand alone 19 rack Color Trafic black RAL 9017 Silver RAL 9006 Weight PLM 4P125 Approx 15 kg Approx 33 Ib PLM 4P220 Approx 18 kg Approx 39 7 Ib 11 2 3 Call Station Base dimensions H x W x D 50 x 156 x 140 mm 2 x 6 1 x 25 5 in Microphone stem length 390 mm 15 35 In Color Trafic black RAL 9017 Silver RAL 9006 Weight Approx 0 77 kg Approx 1 69 Ib 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Technical Data en 51 11 2 4 Wall Control Panel Base dimensions H x W x D 130 x 100 x 30 mm 5 1x3 9x1 2 in Mounting Surface mount bracket Color Trafic black RAL 9017 Silver RAL 9006 Weight Approx 0 13 kg Approx 0 29 Ib Bosch Security Systems B V Operation manual 2013 06 V1 0 52 en Technical Data 11 3 11 3 1 11 3 2 11 3 3 11 3 4 11 4 Environmental conditions DSP Matrix Mixer PLENA matrix Operating temperature 10 C to 45 C Storage temperature 40 C to 70 C Relative humidity lt 95 Multi Channel DSP Amplifier Operating temperature 10 C to 45 C Storage temperature 40 C to 70 C Relative humidity lt 95 Call Station Operat
4. lt 40dB attenuation LEDs off Mute 3 Input source 4 x LED indicating Line input sources 1 2 3 or off or mic line 1 2 3 or 4 selection LED 4 Input source A paper label to identify input sources can be inserted behind the thin plastic cover label Paper labels can be typed and printed out via the PC GUI software 5 Input source Capacitive button to toggle through the connected line input sources 1 2 3 or off selection button or mic line 1 2 3 or 4 input source Continue with Select the input source page 36 Adjust the audio output volume level page 36 Bosch Security Systems B V Operation manual 2013 06 V1 0 36 en Operation PLENA matrix 8 3 1 Select the input source 1 Select the input source with the capacitive touch button labelled Select The input source selection LED indicates the input source or off NOTICE The source microphone inputs or line inputs ID and zone selection are pre defined at configuration Refer to Wall Control Panel DIP switch settings page 24 8 3 2 Adjust the audio output volume level 1 Press the capacitive touch buttons up or down arrows to adjust audio level One touch per 3 GB step 2 The volume control LED indicates the audio output volume level The maximum level indicated is dependent upon the predefined maximum allowable level that is set in the PC GUI DSP setup output level Notice Use slow d
5. 2 70 T 740 oY 1007 1d 4 Output 3 d4 Output 4 Input2 Input3 Input 4 DT o an on TOV 1007 0000600600 o0000000 Link Act 100Mbps 0000000 o0000000 ie zu i Network p 7 8910 11 Number Item Description 1 Power on off AC mains power switch 2 Mains inlet AC mains input socket 3 Loudspeaker 4x loudspeaker outputs via Phoenix terminal outputs Connections 100V 70V 80hm 40hm and OV 4 Fan grille Exhaust air vent for amplifier cooling Do not obstruct 5 XLR TRS combo 4x XLR 3 pin balanced line level audio input 1 4 Mainly used when the inputs loop out amplifier is not connected to the DSP matrix mixer standalone amplifier The inputs outputs are internally in parallel connected with the associated Phoenix input connectors for use as either input or loop through output XLR 3 pin number connection 1 ground 2 signal 3 signal 6 Phoenix inputs 4x 3 pole Phoenix connector audio input 1 4 loop out The inputs outputs are internally in parallel connected with associated XLR TRS combo input loop out connectors for use as either input or output Left to right pin configuration 1 signal 2 signal 3 ground 7 Amp Link 1x RJ45 connector Connects 4 sequential channels of the amplifier to the DSP
6. GUI You can then control the system Write configuration to device This will send the configuration that is on the PC GUI to the unit You are now online The green Online Light should be illuminated on the GUI screen Notice When selecting Write configuration to device You will clear and wipe all existing setting on the device There is no undo button for this after the task has been completed 6 Changing details of the unit To change the unit from DHCP to a static IP configuration follow the procedure above to open the connect to target window Once in the unit is selected you can change 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Configuration en 27 Turn DHCP on off Seta static IP address Change the device name for easy identification in larger systems 7 The GUI should now be connected and online in the User page where inputs can be mixed into different zones 8 To access the DSP configuration page go to Config in the menu bar and select DSP setup Notice For more information regarding the operation of features within the GUI please read the GUI operation document DSP matrix mixer PC GUI control functions User page PLM 8M8 Active Zone Zone 1 A gt EAT ER I EEE Figure 7 1 DSP matrix mixer GUI main screen Mixing and Level control of the 4 Mic line inputs per zone Selection of the Line inputs and level c
7. connection matrix mixer Processor output channels 1 4 or 5 8 For best practice Bosch recommends use with STP CAT 5 e cable Maximum recommended cable distance 5m 8 Auto Standby 4 pole Phoenix connector to attach a Bosch motion sensor to activate auto Mode standby connections The amplifier also can supply 12V DC power for a motion detector Left to right pin configuration 1 12V DC 2 OV DC 3 Sensor 4 Sensor 9 Override input 4 pin pluggable screw socket connector with ESD protection Logic override input and shield balanced input Bosch Security Systems B V Operation manual 2013 06 V1 0 20 en Connections Number Item PLENA matrix Description 10 Active Contact closure to activate the Override input Use the 0 VDC from the sensor above as the common 11 Network RJ45 Ethernet communication socket Communication with the PLENA matrix GUI application Warning The 12V DC power output Auto Standby connection should be only connected with products in accordance with recommendations outlined in this manual Notice Recommended motion sensors for use with the auto standby mode are the Bosch range of sensors For more information regarding Bosch security products contact your local Bosch Security certified partner or go to www boschsecurity com for details Notice It is recommended that the cable used Amp Li
8. green 3dB from clip amber or OdB red clip 6 RS485 LED Indicates RS485 bus communication call stations wall control panels 7 Network LED Indicates network PC communication e g communication with the PC GUI Bosch Security Systems B V Operation manual 2013 06 V1 0 40 en Operation PLENA matrix 8 5 1 Activate the override input function The active override function is used when you want to temporarily override all existing configurations on all outputs with a signal supplied by the override audio input 1 2 3 4 5 i 7 9 10 an Amp Link Out 1 4 Saiti Gaita e ats J NA Control Panels O O O O O 5 O les Amp Link Out 5 8 sat ban OMic Line 1 oMic Line 2 OMic Line3 OMicfline4 Llne5 line6 Line7 5 Network wh Call Stations 8 11 1 Trigger the active audio override contact closure on the units rear panel 7 via the phoenix connection labeled Active The override input signal 8 now has a higher priority than all the other input sources and is active immediately into all channels By opening the contact again the override input signal stops The unit will restore and return to its prior configuration immediately 2 Activate the Force into override via the PC GUI The override input signal overrules all active audio signals 8 5 2 Activate the Alert EVAC override function These overrid
9. group touch the capacitive area again LED is off 2 Multiple zone groups can be selected by continuing to use the numbered capacitive touch areas Push the press to talk PTT button When the LED above the PPT button goes green you are ready to talk Refer to Call Station page 33 Only one call station in the system is able to make an announcement at one time Notice Use slow deliberate touches on the capacitive touch areas on products Excessively fast tapping may not be recognized by the unit A good rule when making an announcement through the call station is to keep at least one hands distance away from the microphone This will reduce popping noises and distortion in the system 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Operation en 35 8 3 Wall Control Panel The wall control panel is used to select the input source and to adjust the audio volume level in the pre selected loudspeaker zones BOSCH 1 3 o o o o z o 2 E 4 o o m o o SELECT 5 Number Item Description 1 Volume level up 2 x capacitive button to control the zone audio volume level up or down down button 2 Volume control 8x LED indicating the selected audio source s volume level LED Top LED OdB attenuation 6dB attenuation 12dB attenuation 18dB attenuation 24dB attenuation 30dB attenuation 36dB attenuation Bottom LED
10. mixer to the last wall control panel on is 500m This may be extended with the use of better cable and less wall control panels on that cable run If the cables are exposed use black or white CAT 5 cables This makes for a better visual look once installed Bosch Security Systems B V Operation manual 2013 06 V1 0 16 en Installation PLENA matrix 5 4 PC GUI software Configuration of the DSP matrix mixer system inputs outputs settings and controls is done by the PLENA matrix graphical user interface GUI PC software Use the Amplifier PC software GUI when configuring the multi channel DSP amplifier It is important to always use the most up to date version of the PC GUI Please check www boschsecurity com for the latest software updates 5 4 1 PC requirements The Plena Matrix GUI configuration application software packages can be installed on any PC running the Microsoft Windows XP SP3 Windows Vista Windows 7 or Windows 8 non RT operating system Make sure that the PC is working correctly and free of viruses before installing the GUI configuration software Using embedded operating systems is not recommended Notice Be sure that you use a user account with full Windows administration rights before starting software installation 5 4 2 PC GUI application software installation The following instructions explain how to install the Bosch Plena Matrix GUI application software onto your Windows PC 1 Downl
11. right atmosphere 3 2 Scope of delivery Make sure that the following items are included with your product PLM 8M8 8 Channel DSP Matrix Mixer 1x Safety instructions 1x Mains power cord 1x Set of 19 mounting brackets PLM 4Px2x Multi Channel DSP Amplifiers 1x Safety instructions 1x Mains power cord 2x 12 pole euro phoenix connectors 2x 4 pole euro phoenix connectors 1x 1 m 26AWG x 4 pair shielded CAT 5e cable 1x Set of 19 mounting brackets PLM 8CS 8 Zone Call Station N A PLM WCP Wall Control Panel 1x Wall mount bracket Bosch Security Systems B V Operation manual 2013 06 V1 0 12 en Planning 4 PLENA matrix Planning Make sure that You make use of manufacturer specified installation materials No liquids can spill into or on the products Installation is in a clean environment free of dust and belly button lint The ventilation airflow of the 19 units is not obstructed There is a mains power outlet of sufficient rating close to the intended location of the products Sufficient free space and access at the rear of the 19 units for connectors and wiring Check you have downloaded the latest versions of documentation and software from the Bosch website www boschsecurity com 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Installation en 13 5 Installation Hardware and software ins
12. start up LEDs flash in a LED sequence 4 PTT LED Bi color LEDs above the PTT button indicating Red Busy Another call station is currently making a call announcement This call station cannot be used to make a paging call until the current call announcement is finished Yellow Wait Your paging call is attempting to start Do not speak yet Green Ready The call station microphone is active you may talk 5 PTT button Press to talk paging call button Keep button pushed down to continue to talk Continue with Pre settings and selections page 34 Making an announcement page 34 Bosch Security Systems B V Operation manual 2013 06 V1 0 34 en Operation 8 2 1 8 2 2 PLENA matrix Pre settings and selections The following pre selections and settings have to be done by the DSP matrix mixer PC GUI application at configuration of the system Refer to DSP matrix mixer PC GUI page 26 Setting button functions zone groups per call station see PC GUI help file for more information Chime generation enable disable Microphone gain control The call station ID setting is pre defined at configuration Refer to Call Station DIP switch settings page 23 Making an announcement 1 Select zone s by touching the numbered capacitive zone selection areas The zone selection LED indicates the zone group to which the announcement is distributed To deselect the zone
13. the active override audio input function The active audio override function is used when you want to temporarily override all existing configurations on all amplifier outputs with a signal supplied by the override audio input 3 4 5 ax 6 4x 8 4 2 d 4 Output 1 d 4 Output 2 1 T 1 an 8 Tv 1000 0 42 an TOV 100m O O O ED Link3 Link 4 o LES Er Tees o 1d Output 3 1d Output 4 input 2 Input3 Input 4 va T o an a 7w 0w 8 t me be eat 2833 oo 338 328 833 00000000 SI 382 71 Und 1004s 0000000 II a 52 a a Si a 00000000 O I O O O O Input 1 Input 2 Input 3 Input 4 Amp Link Input Network j l a 7 12a 13 14 7 8910 11 1 Trigger the active audio override contact closure on the amplifier rear panel 10 via the phoenix connection labelled Active The override input signal now has a higher priority than all the other input sources and is active immediately into all channels 2 By opening the contact again the override input signal stops The unit will restore and return to its prior configuration immediately Activate the amplifier auto standby The amplifier auto standby function is used when you want to switch the amplifier to standby mode Standby mode activates to save power which reduces running costs and extends the lifetime of the amplifier You c
14. 8 5 DSP Matrix Mixer 39 Bosch Security Systems B V Operation manual 2013 06 V1 0 4 en Table of Contents PLENA matrix 8 5 1 Activate the override input function 40 8 5 2 Activate the Alert EVAC override function 40 8 5 3 Operating the DSP Matrix Mixer system with the GUI 40 9 Troubleshooting 41 9 1 Customer service 44 10 Maintenance 45 10 1 Clean the units 45 10 2 Clean air vents 45 10 3 Check the connectors and grounding 45 11 Technical Data 46 11 1 Electrical 46 11 1 1 DSP Matrix Mixer 46 11 1 2 Multi Channel DSP Amplifier 47 11 1 3 Call Station 49 11 1 4 Wall Control Panel 49 11 2 Mechanical 50 11 2 1 DSP Matrix Mixer 50 11 2 2 Multi Channel DSP Amplifier 50 11 2 3 Call Station 50 11 2 4 Wall Control Panel 51 11 3 Environmental conditions 52 11 3 1 DSP Matrix Mixer 52 11 3 2 Multi Channel DSP Amplifier 52 11 3 3 Call Station 52 11 3 4 Wall Control Panel 52 11 4 Standards 52 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Safety en 5 Safety Prior to installing or operating products always read the Important Safety Instructions which are available as a separate multilingual document Important Safety Instructions Safety_ML These instructions are supplied together with all equipment that can be connected to the mains supply Safety precautions The DSP matrix mixer and the DSP amplifiers are designed to be connected to the public distribution network To avo
15. B every time you press the button You should listen to audio through the PA system to confirm that this is the case Call station s microphone becomes active without the user touching the PTT button Multiple call stations have been set with the same ID Change call stations to have different IDs Call stations Wall Control Panels do not work Lights continue to flash around The DSP matrix mixer is not able to configure the unit Check that all cables in the cable run are using the correct CAT 5 pin configuration no crossover cables Check if a cable has been damaged in the daisy chain The call station is activated but announcement did not come through the system Unit has just been turned on Achime has been programmed to play before any announcement The announcement level is not at a sufficient level for the selected zone The user is not speaking loudly enough towards the microphone Wait 15 seconds until unit has been identified by the DSP matrix mixer before attempting to use it Wait for LEDs to turn green on the call station before talking or deactivate the chime via the GUI Within the GUI check that all call station levels are set to appropriately and the mute is not activated Speak slowly and clearly towards the microphone Rack units are not found in target search Ethernet cables have been disconnected
16. M 8M8 DSP Matrix Mixer over standard CAT 5 cables The control is over the RS485 protocol and can be looped through to add more call stations to the system PLM WCP Wall Control Panel BOSCH The Wall Control Panel is used to select and control the volume of input sources within in a particular zone The unit can set up to either select the background music BGM input source or to mix the four mic line input sources within a zone The connection uses the same CAT 5 cabling and RS485 protocol as the PLM 8CS 8 Zone Call Station and is also powered via the PLM 8MB8 DSP Matrix Mixer Installation of the wall control panel is via the supplied wall mount bracket PC Configuration and User GUI Active Zone Zone 1 The PC GUI offers a configuration page and user operation page to setup and control the PLM 8M8 DSP Matrix Mixer and also the PLM 4Px2x Amplifiers The software GUls are able to be downloaded from the Bosch website www boschsecurity com 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix System overview en 11 3 1 Application area The PLENA matrix product range is designed to be used in small to medium sized public address application areas such as hotels shops supermarkets restaurants bars canteens gyms showrooms regional airports warehouses educational facilities theatres back of house and other places where announcements and background music BGM creates the
17. Periodically check All cable connections for corrosion and the screw terminals to make sure that they have not become loosened The ground PE connection of the system components Bosch Security Systems B V Operation manual 2013 06 V1 0 46 en Technical Data PLENA matrix 11 Technical Data 11 1 Electrical 11 1 1 DSP Matrix Mixer Power supply Mains voltage Nominal input voltage 100 240 VAC 10 50 60 Hz Input voltage limits 90 264 VAC Power consumption No devices connected lt 10 W Max load max devices connected 54 W Performance Frequency response 1dB 20 Hz to 20 kHz 0 3 dB Mic line input 4x Input Clip level Pad off 8 4 dBu 6 2 dBV Padon 24 2 dBu 21 9 dBV CMRR 1 kHz O dBFS gt 46 dB Phantom power supply 48 V THD lt 0 01 Dynamic range A weighted gt 103 dB Connectors 4x XLR TRS combo BGM inputs 3x Input clip Pad on 10 2 dBu 8 dBV THD lt 0 004 Dynamic range A weighted gt 103 dB Connectors 3x pair of Cinch RCA Outputs Output level 17 7 dBu 15 5 dBV 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Logic inputs Technical Data en 47 Connector 2 pole Phoenix terminal metric 8CS and WCP RS485 Call station connector 1x RJ45 Wall control panel connector 1x RJ45 Ampl
18. Public Address system BOSCH PLENA matrix Table of contents Table of Contents en 3 1 Safety 5 1 1 FCC and ICES 5 2 About this manual 7 2 1 Manual purpose 7 2 2 Digital document f 2 3 Intended audience 7 2 4 Alerts and notice signs T 2 5 Copyright and disclaimer 7 2 6 Document history 8 3 System overview 9 3 1 Application area 11 3 2 Scope of delivery 11 4 Planning 12 5 Installation 13 5 1 DSP Matrix Mixer and Amplifiers 13 5 2 Call Station 14 5 3 Wall Control Panel 15 5 4 PC GUI software 16 5 4 1 PC requirements 16 5 4 2 PC GUI application software installation 16 5 5 iOS GUI software 17 6 Connections 18 6 1 Call Station 18 6 2 Wall Control Panel 18 6 3 Multi channel DSP Amplifier 19 6 4 DSP Matrix Mixer 21 7 Configuration 23 7 1 Call Station 23 71 1 Call Station DIP switch settings 23 7 2 Wall Control Panel DIP switch settings 24 7 3 Multi Channel DSP Amplifier settings 25 7 4 DSP matrix mixer PC GUI 26 7 5 Multi Channel DSP Amplifier PC GUI 28 7541 Amplifier Bridging Configuration 31 8 Operation 32 81 Start 32 8 2 Call Station 33 8 2 1 Pre settings and selections 34 8 2 2 Making an announcement 34 8 3 Wall Control Panel 35 8 3 1 Select the input source 36 8 3 2 Adjust the audio output volume level 36 8 4 Multi Channel DSP Amplifier 37 8 4 1 Activate the active override audio input function 38 8 4 2 Activate the amplifier auto standby 38 8 4 3 Operate the amplifier with the PC GUI 38
19. UI software page 16 installation to install the PC GUI if needed Proceed as follows Notice Changes and updates to this procedure are available in the software down load file 1 Complete the installation of the PC GUI software Refer to PC GUI application software installation page 16 for more information 2 Open the PC GUI software program 3 The DSP PC GUI configuration program starts and the user screen should appear An offline configuration for the DSP matrix mixer can be made and saved onto the PC without connection to the unit This can be saved and uploaded at a later time if required 4 To make a connection to the DSP matrix mixer make sure that an Ethernet cable is connected to the network port of the DSP matrix mixer 5 To connect to the unit via PC GUI Inthe Tool bar Click Device and then click Connect The Connect to target window will open Note If the Connect is grayed out Please enter the administrator password hardware password under the Admin menu or contact the installer assistance Click Search Refresh to discover the active units connected to the network Select the unit you wish to control Click on which way you would like the data to flow during connection either Read configuration from device or Write configuration to device buttons Read configuration from device This will read or extract the settings from the selected unit and display them on your PC
20. Unit s and or router are not on PC is not connected to network Check all unit are connected to power check cabling is correctly connected check that the PC is connected to the network Bosch Security Systems B V Operation manual 2013 06 V1 0 44 en Troubleshooting PLENA matrix 91 Customer service If a fault cannot be resolved please contact your supplier or system integrator or go directly to your Bosch representative 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix 10 Maintenance en 45 Maintenance The PLENA matrix system has been designed to operate without problems for a long period of time with a minimum of maintenance In order to guarantee trouble free operation Clean the units page 45 Clean air vents page 45 Check the connectors and grounding page 45 Warning Dangerous mains voltages are present inside the 19 units Disconnect the mains power supply before you do any maintenance 10 1 10 2 10 3 Clean the units Periodically clean all units with a damp lint free cloth never use water or chemicals Clean air vents The multi channel DSP amplifier can collect dust as a result of the internal fan Base the interval on the actual situation and dust build up Start with an interval of at least once a year Use a vacuum cleaner to clean the air vents of all units Check the connectors and grounding
21. an set the length of time that there is no activity in a zone using the amplifier DSP The timeout can be as fast as 1 minute or as long as 4 hours Factory preset is 60 min 1 Once a movement sensor has been correctly connected and powered 8 any activity that is detected by sensor resets the standby timeout period 2 When the timeout has been reached the amplifier will switch into a highly efficient power saving mode During standby if activity is detected via the sensor or an Active Alert EVAC contact closure is engaged the amplifier wakes up and restore and return to its prior configuration immediately Notice The recommended sensor to be used and can be powered by the amplifier is the Bosch PIR range of detectors Refer to www boschsecurity com 8 4 3 Operate the amplifier with the PC GUI Operating and configuration of the DSP features can only be used via the amplifier PC GUI Refer to Multi Channel DSP Amplifier PC GUI page 28 Operation instructions are available within help of the PC GUI 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Operation en 39 8 5 DSP Matrix Mixer The DSP matrix mixer the brains of the PLENA matrix system It has no external controls on the unit itself To control this unit it requires either connection to the call station and or wall control panel or a online connection to the PC GUI Notice It is
22. e if a short is on the output but no signal is being driven the amplifier may not actually be in fault mode As soon as enough signal is present to activate the current protection the fault LED will light Amplifier Fault LED flashes quickly for around 30 seconds This indicates a thermal error on the channel The channel will be re activated after it has cooled down Amplifier Fault LEDs flash slowly This indicates that the PSU has failed or thermally cut out Send immediately for service and or contact the Bosch authorized dealer or installer for assistance Call stations Wall Control Panel s LED keep rotating RS485 ID cannot be identified Check that the switches have been full switched to the appropriate positions and reset power to the unit Check that the CAT 5 cable is not damaged in anyway Download and connect with the latest version of PC GUI and check the RS485 status Device gt RS486 device status 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Problem Possible cause Troubleshooting en 43 Possible solution Wall Control Panel volume control takes two button presses to increase the LED indicator The LEDs only indicate 6dB steps The up down arrows increase decrease the volume in 3dB steps Be assured the unit is not faulty or broken The unit will be affecting the audio at 3d
23. e functions are used when you want to override all existing configurations in all zones with an internally generated alarm signal 1 Activate the audio override via contact closures the units rear panel 7 using an external device The override input signal overrules all active audio signals By opening the contact again the override tone stops The unit will restore and return to its prior configuration immediately 2 Activate the Force into Alert Tone or Force into EVAC Tone via the PC GUI The override input signal overrules all active audio signals 8 5 3 Operating the DSP Matrix Mixer system with the GUI Operating and configuration of the DSP features can only be used via the DSP matrix mixer PC GUI Refer to DSP matrix mixer PC GUI page 26 Operation instructions are available within the help of the PC GUI 2013 06 V1 0 Operation manual Bosch Security Systems B V Troubleshooting Troubleshooting en 41 Problem Possible cause Possible solution DSP matrix mixer or amplifier does not work and power LEDs are not illuminated Power plug disconnected and or the unit is switched off Insert power cord and switch on the unit DSP matrix mixer or amplifier No audio An audio output cable has come loose or has not been properly plugged in Within the PC GUI controls the input or output levels have been muted or reduced to a very low level Input source is not work
24. e installed Refer to Call Station page 18 Notice The maximum number of call station IDs that can be configured for each DSP matrix mixer is 8 call stations The maximum safe cable distance from the DSP matrix mixer to the last call station on is 500m This may be extended with the use of better cable and less call stations on that cable run If the cables are exposed use black CAT 5 cables This makes for a better visual look once installed as it matched the black of the call station 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix 5 3 Installation en 15 Wall Control Panel A wall control panel is installed as a wall surface mount product that allows two methods of cable entry This allows the same product to be used for both solid masonry walls where cables are often run externally down a wall then enter the unit from above or alternatively on frame constructions where cables are inside the cavity and need to be hidden 1 Be sure to plan for easy cable entry into unit before affixing the bracket to the surface Be sure that there are no electrical cables that will be obstructed or compromised by the method of fixing the bracket i e screws The textured surface should be facing the wall This surface texture assists the use of adhesives if required Be sure that the bracket is level and is straight before attaching to the wall Allow enough space above the brac
25. ect the interference at his own expense Intentional or unintentional changes or modifications not expressly approved by the party responsible for compliance shall not be made Any such changes or modifications could void the user s authority to operate the equipment If necessary the user should consult the dealer or an experienced radio television technician for corrective action The user may find the following booklet prepared by the Federal Communications Commission helpful How to identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 Bosch Security Systems B V Operation manual 2013 06 V1 0 6 en Safety PLENA matrix Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix 2 1 2 2 2 3 2 4 About this manual en 7 About this manual Please read this manual carefully before installing and operating any of the PLENA matrix public address products and retain it for future reference Manual purpose The purpose of this manual is to provide information required for installing configuring operating and maintaining the PLENA matrix public address Hardware products For instructions on the la
26. ee also DSP Matrix Mixer and Amplifiers page 13 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Configuration en 23 7 Configuration Call Station DIP switch settings page 23 Wall Control Panel DIP switch settings page 24 Multi Channel DSP Amplifier settings page 25 DSP matrix mixer PC GUI page 26 Multi Channel DSP Amplifier PC GUI page 28 7 1 Call Station Configuration of zone groups printable labels for the call stations and chimes is done via the PC software GUI Refer to DSP matrix mixer PC GUI page 26 7 1 1 Call Station DIP switch settings DIP switches are use to set individual ID numbers to the call stations This is so it can be recognized by the DSP matrix mixer in the system Each connected call station must have its own individual ID assigned 1 To set the call station ID use the 3 way DIP switch on the base of the unit Factory default ID setting call station 1 all switches are OFF Call station ID numbers DIP switch 1 2 3 4 5 6 7 8 1 OFF ON OFF ON OFF ON OFF ON 2 OFF OFF ON ON OFF OFF ON ON 3 OFF OFF OFF OFF ON ON ON ON Factory default Notice A DIP switch in the down position is OFF A DIP switch in the up position is ON Eg Down Up Down will equal call station ID number 3 in the table above Bosch Security Systems B V Operation manual 2013 06 V1 0 24 en Configuration PLENA matrix
27. eliberate touches to the capacitive touch areas on products Excessively fast tapping may not be recognized by the unit Notice The level will increase or decrease 3dB for every button press of the arrows and the LED is 6dB per step Therefore it will sometimes require 2 pushes to see the next LED illuminate 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Operation en 37 8 4 Multi Channel DSP Amplifier The multi channel amplifier s DSP is able to be used to process audio signals for up to 4 zones The amplifiers can be used either with or without the DSP functionality The amplifier can be used standalone or connected to the DSP matrix mixer Refer to DSP Matrix Mixer page 21 if the amplifier is only connected to the DSP matrix mixer and loudspeaker output zones 1 2 4 BOSCH D 2 ne N I Number Item Description 1 Power on LED Flashes green during power up It becomes solid green as soon the amplifier is ready for use 2 Input signal Two LEDs per amplifier input channel 4x indicating LEDs Protect fault On red indicates an amplifier fault Refer to Troubleshooting page 41 section Signal presence clip bi color LED On when the applied audio input signal is 40dB from clip green 3dB from clip amber OdB full output power red Standalone without connection to the PC GUI After following the guide on setting up the input sensitivity and bridging if requi
28. evel sensitivity and bridge mode setting sensitivity Switch 1 Input Sensitivity Channel X 6 15V UP 1 22V DOWN input bridge input 1 sensitivity Default DOWN and 2 shown Switch 2 Bridge Channels X Y Active UP Single channel mode DOWN Default DOWN Switch 3 Input Sensitivity Channel Y 6 15V UP 1 22V DOWN input sensitivity Default DOWN 14 Input 3 way DIP switch for input level sensitivity and bridge mode setting sensitivity Switch 1 Input Sensitivity Channel X 6 15V UP 1 22V DOWN input bridge input 3 sensitivity Default DOWN and 4 shown Switch 2 Bridge Channels X Y Active UP Single channel mode DOWN Default DOWN Switch 3 Input Sensitivity Channel Y 6 15V UP 1 22V DOWN input sensitivity Default DOWN Notice Hardware settings cannot be overruled or changed by the GUI configuration software See also DSP matrix mixer PC GUI page 26 Bosch Security Systems B V Operation manual 2013 06 V1 0 26 en Configuration PLENA matrix 7 4 DSP matrix mixer PC GUI All audio set up configurations for the DSP matrix mixer are done via the PC software GUI With the DSP matrix mixer PC GUI audio input levels audio output levels and controls could be set via the connected PC Notice It is impossible to configure the DSP matrix mixer s advance DSP settings without this PC GUI installed and connected Refer to PC G
29. id any risk of electric shock all interventions must be carried out with disconnected mains supply The ventilation should not be impeded by covering the ventilation openings with items such as news papers table cloths or curtains Connection of external wiring to this equipment requires installation by qualified personnel only The operation must only be performed by qualified personnel Use the apparatus in moderate climate Caution These service instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so 1 1 FCC and ICES U S A and Canadian models only Business Equipment For commercial or professional use Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules and ICES 003 of Industry Canada These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in residential area is likely to cause harmful interference in which case the user will be required to corr
30. ifier 2x Connector RJ45 Nominal level 1V Impedance lt 100 ohm Ethernet 10 100 Mbit s 1x Connector RJ45 Notice Maximum load means maximum two multi channel amplifiers call stations and wall control panels connected 11 1 2 Multi Channel DSP Amplifier Power supply Mains voltage Nominal input voltage 100 240 VAC 10 50 60 Hz Input voltage limits 90 264 VAC Power consumption 6dB idle standby PLM 4P125 254W 27W 6W PLM 4P220 412W 36W 6W Performance Rated outputs voltage impedance 100 V 70V 8ohm 4ohm Rated output power per channel continous PLM 4P125 130 W PLM 4P220 220 W Rated output power per channel burst Bosch Security Systems B V Operation manual 2013 06 V1 0 48 en Technical Data PLENA matrix PLM 4P125 130 W PLM 4P220 220 W Bridged CH 1 2 3 4 continous PLM 4P125 250 W PLM 4P220 385 W Bridged CH 1 2 3 4 burst PLM 4P125 250 W PLM 4P220 445 W THD N 1 kHz 6 dBFS PLM 4P125 0 1 PLM 4P220 0 03 Dynamic range A weighted PLM 4P125 gt 101 dB PLM 4P220 gt 102 dB Frequency response 1dB 65 Hz to 20 kHz 0 3 dB Crosstalk 1 kHz lt 70 dB According to CEA 490 A R 2008 Connectors Inputs wired in parallel 4x 3
31. impossible to control zone volume levels without one of the following wall control panel PC or iOS GUI Refer to PC GUI software page 16 to install the PC GUI if needed BOSCH Sat tae a en i a OF ling ma a 7 a 1 2 3 4 5 67 Refer to the following table to check the indicators of the functionality in use Number Item Description 1 Power on LED Flashes green during power on and initialization It becomes solid green as soon the unit system is ready for use 2 Mic Line 1 4 2x bi color LED per microphone line input 4x indicating level LED Microphone 48 V phantom power supply LED On yellow when phantom power supply is supplied to the connected microphone Signal presence Clip LED On when applied signal is 40dB from clip green 3dB from clip amber OdB red clip 3 Line input LED Bi color LED per background music source input 3x indicating Signal presence Clip LED On when applied signal is 40dB from clip green 3dB from clip amber or OdB red clip 4 Call station LED 2x bi color LED on the call station input indicating signal Announcement active LED On yellow when a call station is making an precense clip announcement LED Signal presence Clip LED On when applied signal is 40dB from clip green 3dB from clip amber or OdB red clip 5 Output 1 8 LED Bi color LED per zone output 8x indicating Signal presence Clip LED On when applied signal is 40dB from clip
32. ine out 5 Mic Line input 4x XLR balanced microphone line level audio input 1 4 XLR 3 pin number connection 1 ground 2 signal 3 signal 6 Line inputs 3x2 RCA summed line input sockets for external music sources 7 Active contact 4 pin pluggable screw socket connector with ESD protection From left to right Pin 1 Alert Pin 2 evac Pin 3 override Pin 4 ground Pin 1 2 and 3 logic inputs triggers with ground pin 4 8 Override input 4 pin pluggable screw socket connector with ESD protection Audio line level analog override input and shield balanced input 9 Network RJ45 Ethernet communication socket Communication with the PLENA matrix GUI applications 10 Wall control RJ45 socket for RS485 data communication power and audio bus panel Do not connect any other device other than wall control panels Maximum 16 daisy chained wall control panels Maximum safe cable distance 500 m 1640 42 ft to the final unit 11 Call station RJ45 socket for RS485 data communication power and audio bus Do not connect any other device other than call stations or wall control panels Maximum 8 daisy chained call stations Maximum safe cable distance 500 m 1640 42 ft to the final unit Bosch Security Systems B V Operation manual 2013 06 V1 0 22 en Connections PLENA matrix Notice Hardware settings cannot be overruled or changed by the PC GUI application software S
33. ing correctly Check all input and output audio connections Plug in audio cables properly Check the audio levels in the PC GUI are not muted or set to a level that is too low Check the input source is working correctly and sending an appropriate level of signal DSP matrix mixer or amplifier The audio output sound is distorted or sounds strange The audio output cable has not been properly plugged in The correct cables have not been used The input level is clipping Music source material is not correct Check all connections have been made and plugged in properly Check the recommended cables have been used Turn down the input level in the PC GUI configuration screen Switch music source Amplifier Fault light constantly ON Red Indicates a fault with that amplifier channel Send immediately for service and or contact the Bosch authorized dealer or installer for assistance Bosch Security Systems B V Operation manual 2013 06 V1 0 42 en Troubleshooting Problem Possible cause Possible solution PLENA matrix Amplifier Fault light lit for approx one second This is indicating protection on that channel overload or short condition The amplifier automatically retries the channel after this time 1 min Note that the amplifier will not detect a short circuit directly without signal for instanc
34. ing temperature 10 C to 45 C Storage temperature 40 C to 70 C Relative humidity lt 95 Wall Control Panel Operating temperature 10 C to 45 C Storage temperature 40 C to 70 C Relative humidity lt 95 Standards EMC emission According to EN55103 1 EMC immunity According to EN55103 2 2013 06 V1 0 Operation manual Bosch Security Systems B V Bosch Security Systems B V Torenallee 49 5617 BA Eindhoven The Netherlands www boschsecurity com Bosch Security Systems B V 2013
35. install the PC GUI if needed Proceed as follows Notice Changes and updates to this procedure are available in the software down load file 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Configuration en 29 Complete the installation of the PC GUI software Refer to PC GUI application software installation page 16 for more information Open the PC GUI software program The amplifier PC GUI program should open and the user screen should appear An offline configuration of the amplifier can be made without connection to a DSP matrix mixer and uploaded to the DSP matrix mixer at a later time optional To make a connection to the hardware make sure that an Ethernet cable is connected between the PC and to the network port of the amplifier To connect to the unit via PC GUI Inthe Tool bar Click Device and then click Connect The Connect to target window will open Note If the Connect is grayed out Please enter the administrator password hardware password under the Admin menu or contact the installer assistance Click Search Refresh to discover the active units connected to the network Select the unit you wish to control Click on which way you would like the data to flow during connection either Read configuration from device or Write configuration to device buttons Read configuration from device This will read or extract
36. ket so that when attaching the wall control panel it is not obstructed 2 Set the rear panel DIP switches before the wall control panel is locked into bracket Refer to Wall Control Panel DIP switch settings page 24 3 Connect the RJ45 connector s located on the base of the unit before the wall control panel is attached to bracket Be sure to plan and consider the bend radius of cables It strongly recommended that the shortest possible RJ45 connector is used when terminating this is to maximize bend radius of cables in the confined space Refer to Wall Control Panel page 18 4 Place wall control panel onto bracket Once the 4 lugs have been placed correctly onto the unit slide the unit down the bracket until it clicks into place Ifthe unit does not sit correctly into the lugs be sure that you have not used screw heads that are too big to fit in the channels on the rear of the unit 5 Removing the wall control panel from the bracket if required With the use a flat blade screwdriver press down the bracket locking mechanism located on the bottom right hand side and gently slide the unit upwards this removes the unit from the bracket Notice The maximum number of wall control panel IDs that can be configured via DIP switch is 16 8 BGM controllers and 8 mic line controllers Refer to Wall Control Panel DIP switch settings page 24 for more information The maximum safe cable distance from the DSP matrix
37. nk cable is a high quality STP CAT 5 e cable Amp Link cable distances should not exceed 5 meters per cable 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix 6 4 Connections en 21 DSP Matrix Mixer Call stations and wall control panels are connected to the PLM 8M8 DSP matrix mixer via CAT 5 cable using RJ45 connectors The multi channel DSP amplifiers are connected to the DSP matrix mixer either via Amp Link or via the output Phoenix connectors All other connected wiring must be of a professional quality and preferable screened 3 4 5 i 7 9 10 Amp Link Out 1 4 eat ars wos route O g Fi A i Control Panels Amp Link Out 5 8 S at sar u OMic Line 1 OMic Line 2 Be DMic Line 4 ElineS Eines E Line7 Ben 5 Network 1 Call Stations 8 11 Number Item Description 1 Power on off AC mains supply switch 2 Mains inlet AC mains input socket 3 Amp Link RJ45 socket for Amp Link connection outputs Amp Link 1 4 output duplicates the outputs of outputs 1 4 Amp Link 5 8 output duplicates the outputs of outputs 5 8 The maximum cable lenght between DSP matrix mixer and the multi channel power amplifier 5 m 16 42 ft Do not connect any device other than a PLM 4Px2x amplifier 4 Phoenix zone 3 pole Phoenix screw terminal connection per output channel outputs Balanced l
38. oad the latest version of PC GUI software from the Bosch website www boschsecurity com Follow the on screen instructions from the setup wizard The installation process is started 2 Click the finish button Notice The installation may prompt you to install Microsoft NET framework 4 0 this is required to be able to run this GUI Please follow the link provided onscreen to download and install before proceeding See also Connections page 18 Configuration page 23 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Installation en 17 5 5 iOS GUI software The iOS GUI is designed for use with iPad or iPad mini This GUI app is designed for the end user who requires more control over the system than is provided by the wall control panel to wirelessly control and mix inputs in individual zones via the PLM 8M8 DSP Matrix Mixer The interface is similar in terms of features to the PC GUI user interface screen The iOS app is available for download via the app store Notice To use the iOS GUI app will require the connection and configuration of a wireless router Please refer to the manual supplied with the wireless router for appropriate configuration Bosch Security Systems B V Operation manual 2013 06 V1 0 18 en Connections 6 PLENA matrix Connections Call Station page 18 Wall Control Panel page 18 Multi channel DSP Amplifier page 19 DSP Matrix Mixer
39. ontrol per zone Master level control per zone Call station input level control per zone Soft standby Global mute Connect to device Bosch Security Systems B V Operation manual 2013 06 V1 0 28 en Configuration PLENA matrix 7 5 DSP setup page Bam ora ora ora ora ora ora ZONE ERRARE BaAnE BAR E ERATE ERARE ERARE ERARE ERARE Figure 7 2 DSP matrix mixer GUI setup screen Input level control iPad 48V HPF Input DRC Dynamic Range Compression Input Parametric EQ Mic Line 5 bands Line inputs 3 bands Assign Crossover 8th order Output Zone EQ 7 bands Delay DRC Dynamic Range Compression Output level Control Output assignment Other DSP matrix mixer configurations in the GUI Priority set up Ducking levels Password set up Call station set up See also Troubleshooting page 41 Multi Channel DSP Amplifier PC GUI All DSP features for the multi channel DSP amplifier are controlled via the PC software GUI With the amplifier PC GUI fault monitoring can be viewed and DSP features can be configured or controlled via the connected PC Notice Unlike the DSP matrix mixer the amplifiers can work as a basic amplifier i e without the use of the DSP features Level controls for each amplifier channel are on the rear of the unit Refer to PC GUI software page 16 installation to
40. or reprints and excerpts contact Bosch Security Systems B V The content and illustrations are subject to change without prior notice Bosch Security Systems B V Operation manual 2013 06 V1 0 8 en About this manual PLENA matrix 2 6 Document history Release date Documentation version Reason 2013 06 18 V1 0 1 Edition 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix 3 System overview en 9 System overview The Bosch PLENA matrix product range consists of high quality products and is the ideal solution to perform zone announcements with excellent speech intelligibility and background music in a wide variety of public address areas The system is designed for maximum flexibility to suit almost any application The installation of is quick and easy because the system uses CAT 5 cables to connect accessories and amplifiers to the DSP matrix mixer PLENA matrix product range comprises PLM 8M8 8 Channel DSP Matrix Mixer E o od The digital signal processor DSP Matrix Mixer is the heart of the PLENA matrix system When combined with the Call Station PLM 8CS and the Wall Control Panel PLM WCP making announcements and controlling individual zones is easy The multi channel DSP amplifiers PLM 4Px2x can be connected via STP type CAT 5 Amp Link or via phoenix terminal connectors The internal audio matrix can control announcements via the call sta
41. ower up of the system it will be obviously be in its factory default state Ifall of the above steps have been followed and the system is not working correctly refer to the Troubleshooting page 41 section of this manual Continue with one of the following chapters Call Station page 33 Wall Control Panel page 35 Multi Channel DSP Amplifier page 37 DSP Matrix Mixer page 39 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Operation en 33 8 2 Call Station The call station is used to make announcements in pre selected loudspeaker zones Notice Upon start up the call stations will need to be identified by the processor During this period the LEDs will flash in a rotating sequence once this is complete the system is ready Allow approx 15 seconds before attempting an announcement 1 rn O N 2 BOSCH 1 gq o 5 Pr a 6 3 _ 3 3 0 o 7 40 2 8 E Number Item Description 1 Microphone Flexible gooseneck microphone stem with paging call activity LEDs green 2 Zone label Paper labels can be inserted behind the thin plastic cover Paper labels can be typed and printed out via the PC GUI software 3 Zone selection This section allows the user to select the zone s that have been previously button configured in the PC GUI Software 3 Zone selection 1 8 selection LED indicator green on zone selected On
42. page 21 6 1 Call Station Call stations are daisy chained connected to the DSP matrix mixer with UTP type CAT 5 cable using RJ45 connectors The connectors are located on the rear side of the call station Item Description Dual RS485 Standard RJ45 socket for RS485 data communication power supply for input output the unit and single channel audio bus Notice If the cables are exposed use black or white CAT 5 cables This makes for a better visual look 6 2 Wall Control Panel Wall control panels are daisy chained connected to the DSP matrix mixer with UTP type CAT 5 cable using RJ45 connectors The connectors are located on the rear of the unit Item Description Dual RS485 Standard RJ45 socket for RS485 data communication and power supply input output for the unit Notice Do NOT use a RJ45 cable boot of sleeve when terminating these cables Using such items may result in the cables not fitting into the device or the bend radius of the UTP to be exceeded 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Connections en 19 6 3 Multi channel DSP Amplifier When the multi channel DSP amplifier is connected to the DSP matrix mixer it is recommended to connect via either Amp Link connectors or the phoenix terminal inputs The amplifier also has XLR TRS combo inputs in case it will be used without the DSP matrix mixer 1 2 3 4 5yax 6 d Output 1 1d Output
43. pin XLR balanced 4x 3 pole balanced Phoenix terminal Metric 1x RJ45 Amp Link Loudspeaker output 4x 3 pole Phoenix terminal Metric Logic and standby overide 2 pole Phoenix terminal Metric Ethernet Network 10 100 Mbps RJ45 12 V output power for motion sensor 2 pole Phoenix terminal Metric 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix 11 1 3 11 1 4 Call Station Technical Data en 49 Power supply supplied by PLM 8M8 Voltage range 30 50 VDC Power consumption 1 5 W Performance Microphone type Cardoid Frequency response 3dB 100 Hz to 20 kHz 0 3 dB Input Clip level 11 dBu 13 3 dBV THD N 1 kHz 6 dBFS lt 0 03 Dynamic range A weighted mid gain setting gt 97 dB A Output level 24 4 dBu 22 2 dBV Connectors 2x RS485 loop through RJ45 Wall Control Panel Power supply supplied by PLM 8M8 Voltage range 30 50 VDC Power consumption 0 5 W Connectors 2x RS485 loop through RJ45 Bosch Security Systems B V Operation manual 2013 06 V1 0 50 en Technical Data PLENA matrix 11 2 Mechanical 11 2 1 DSP Matrix Mixer Dimensions H x W x D 45 x 440 x 358 mm 1 8 x 17 3 x 14 1 in 19 wide 1RU high Mounting Stand alone 19 rack Color Trafic black RAL 9017
44. red 1 Turn on the amplifier 2 Use level controls on the rear of the unit to set desired output level The factory preset configuration is input 1 is routed to output 1 etc All internal levels are set to unity gain 3 If usage with the auto standby mode is required the preset time out is 1 hour With DSP PC GUI functionality After following the guide on setting the input sensitivity and bridging if required 1 Turn on the amplifier 2 Use level controls on the rear of the unit to set desired output level Usually these level controls are set to full as you can adjust the levels down within the PC GUI 3 Open the PC GUI program and click on Device in the menu bar and then click Connect Refer to Multi Channel DSP Amplifier PC GUI page 28 for configuration details 4 If required more information on using the PC GUI can be found in the help menu Refer to Multi Channel DSP Amplifier PC GUI page 28 for DSP features Notice Hardware settings controls and switches cannot be overruled or changed by the DSP matrix mixer and amplifier PC GUI configuration software Bosch Security Systems B V Operation manual 2013 06 V1 0 38 en Operation 8 41 PLENA matrix The following operations can be done when using the amplifier hardware in either mode or operation Activate the active override audio input function page 38 Activate the amplifier auto standby page 38 Activate
45. ry default If all DIP switches are up ON this is ID 16 Notice Hardware settings cannot be overruled or changed by the GUI application software 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Configuration en 25 7 3 Multi Channel DSP Amplifier settings The multi channel DSP amplifier does not require an ID to be connected to the DSP matrix mixer Amplifier settings that are configured by DIP switches are input sensitivity and bridging channels together The DSP features are only able to be configured after you have connected to the unit using the PC software GUI Refer to Multi Channel DSP Amplifier PC GUI page 28 Some amplifier settings are configured by DIP switches such as the input sensitivity and when bridging channels together 1 2 3 4 Sax 6 1d 4 Output 2 o an aa Ty am q 4 Output 3 d4 Output 4 0000000 4 Output 1 u aa aa 7 1 Fort in 0 O 0 Input Input2 Inputs Input Bees R882 FEAA 00000000 I a2 NIIT 3 5 383 Link Act 100Mbps oo oo oo a oo O SS O O O ia s F ik J 12 4x 13 7 8910 11 Number Item Description 12 Line input 4x audio input 1 4 level adjustment control control The range of attenuation is approximately between OdB and gt 50dB 13 Input 3 way DIP switch for input l
46. tallation procedures are described in the following chapters Before installing the rack mounted products 1 Set the mains power switch on the unit s rear panel to the off position The DSP matrix mixer unit and multi channel DSP amplifier operates on AC mains voltage ranging from 100 240VAC 50 60Hz 5 1 DSP Matrix Mixer and Amplifiers The DSP matrix mixer and the multi channel DSP amplifiers are designed for installation into a 19 rack For 19 rack installation use The 19 rack mounting brackets which come with the product Standard M6 mounting screws 16 mm thread depth 20 mm total length Figure 5 1 19 bracket and rack mounting Notice If you install the product into a 19 rack Ensure that it does not exceed the overheating temperature 45 C ambient Use the included Bosch 19 mounting brackets Bosch Security Systems B V Operation manual 2013 06 V1 0 14 en Installation 5 2 PLENA matrix Call Station 1 Acall station is used as a desktop device As such be careful do not place this product where it is likely to have liquid spilt on it 2 Take care to when installing not to exceed the cable manufactures bend radius specifications 3 Be sure that cabling is installed in a way that the cabling will not be damaged and it will not become a hazard 4 Check that RJ45 connectors have strong locking tabs and are not able to be inadvertently pulled out onc
47. test PC GUI software please download the software from the product related information on the www boschsecurity com website Digital document This manual is available as a digital document in the Adobe Portable Document Format PDF Refer to the product related information on www boschsecurity com Intended audience This manual is intended for installers operators and users of a PLENA matrix public address system Alerts and notice signs Four types of signs can be used in this manual The type is closely related to the effect that may be caused if it is not observed These signs from least severe effect to most severe effect are Notice Containing additional information Usually not observing a notice does not result in damage to the equipment or personal injuries Caution The equipment or the property can be damaged or persons can be lightly injured if the alert is not observed Warning The equipment or the property can be seriously damaged or persons can be severely injured if the alert is not observed gt gt e Danger Not observing the alert can lead to severe injuries or death 2 5 Copyright and disclaimer All rights reserved No part of this document may be reproduced or transmitted in any form by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the publisher For information on getting permission f
48. the settings from the selected unit and display them on your PC GUI You can then control the system Write configuration to device This will send the configuration that is on the PC GUI to the unit Note This will overwrite all the current settings in the device You are now online The green Online Light should be illuminated on the GUI screen Notice When selecting Write configuration to device You will clear and wipe all existing setting on the device There is no undo button for this after the task has been completed 6 Changing details of the unit To change the unit from DHCP to a static IP configuration follow the procedure above to open the connect to target window Once in the unit is selected you can change Turn DHCP on off Seta static IP address Change the device name for easy identification in larger systems 7 The GUI should now be connected and online in the User page where inputs can be mixed into different zones 8 To access the DSP configuration page go to Config in the menu bar and select DSP setup Notice For more information regarding the operation of features within the PC GUI please read the PC GUI operation document in the help menu of the PC GUI Refer to DSP matrix mixer PC GUI page 26 when use the amplifier connected to the DSP matrix mixer Bosch Security Systems B V Operation manual 2013 06 V1 0 30 en Configura
49. tion PLENA matrix Functions viewed and or controlled with the amplifier PC GUI configuration page Main page ile Config Device Administrator Window Help PLM 4Px2x m sot standy eee Override Active Onine Output 1 Output 2 Output 3 Output 4 Fault Therm Figure 7 3 Amplifier GUI main screen Output levels for each amplifier channel Fault monitoring Mute per amplifier channel Connect to device DSP setup page INPUT NAME MIX X OVER EQ DELAY DRC OUTPUT OUTPUT NAME BERAE Beate Beka EIRAADE Figure 7 4 Amplifier GUI DSP setup screen 7 Input mixer Crossover Parametric EQ including Bass Enhancement on off Delay DRC Dynamic Range Compression Output Level control See also Troubleshooting page 41 2013 06 V1 0 Operation manual Bosch Security Systems B V PLENA matrix Configuration en 31 7 5 1 Amplifier Bridging Configuration 1 Set the Bridge DIP switch 13 and 14 on the rear of the unit to the ON position 1 2 or 3 4 2 Restart the amplifier as the value of the DIP switches is only read during powering up 3 Wiring the outputs The two channels being bridged together should have the commons OV connected together and then either the 4 8 70V 100V taps off the two channels are then used for the ve and the ve to the speaker cable Warning Bridging the 70V and 100V lines the voltage will be 140V and 200V respectively
50. tion mix four mic line inputs and select any of the three background music sources and deliver these to a total of eight independent zone outputs There is also a logic input for emergency override that will take priority over all other inputs Control of the DSP features is via Ethernet connection and use of the product GUI of Windows or iPad PLM 4P125 and PLM 4P220 Multi channel DSP Amplifiers i Bosch i With the exception of the power output both Class D multi channel DSP Amplifiers are virtually identical in features The amplifiers come with advanced DSP features which are accessed by the PC GUI Both amplifiers feature the Amp Link CAT 5 cable connection to connect easily to the PLM 8M8 DSP Matrix Mixer Loudspeaker outputs are for 100 V 70 V 8 Ohm and 4 Ohm operation The amplifier channels can also be bridged together to make more powerful outputs The amplifiers also feature an auto standby mode that significantly reduces the power consumption making the amplifiers more cost effective and environmentally friendly Bosch Security Systems B V Operation manual 2013 06 V1 0 10 en System overview PLENA matrix PLM 8CS 8 Zone Call Station The 8 Zone Call Station is used to make announcements in designated zone configurations A total of 8 call groups can be configured in the DSP Matrix Mixer and activated via the capacitive touch areas on the surface The call station is powered via the PL

Download Pdf Manuals

image

Related Search

Related Contents

- Electrolube  Modelo 717 - Spartan Tool  Lanier 6110 User's Manual  MODEL # ZX-8680  notice - AJVS.com  RTR-51 User Manual  Atlas User Manual for Locomotives with QSI Quantum (Titan)  ipsogen JAK2 MutaSearch Kit Handbook  Pregao4013 - Justiça Federal  Powerplex Reader User's Manual  

Copyright © All rights reserved.
Failed to retrieve file