Home
Best EB9 User's Manual
Contents
1. Model EB6 Model EB9 For use with compatible Best by Broan range hoods See hood manual for suitability BEST BY BROAN P O BOX 140 HARTFORD WI 53027 READ AND SAVE WARNING TO REDUCE THE RISK OF FIRE ELEC TRIC SHOCK OR INJURY TO PER SONS OBSERVE THE FOLLOWING A EB6 120 2 4 600 EB9 120 5 7 900 Use this unit only in the manner intended by the manufacturer If you have ques tions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on acciden tally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by a qualified person s in accor dance with all applicable codes and stan dards including fire rated construction codes and standards Sufficient air is needed for proper com bustion and exhausting of gases through the flue chimney of fuel burning equip ment to prevent backdrafting Follow the heating equipment manufacturer s guide line and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB THESE WARNING 5 When
2. travers le mur une distance de 216 mm 8 Y po du rebord int rieur d un POTEAU MURAL TUD De l ext rieur sur le mur 3 Mesurez et tracez un rectangle de 629 mm x 718 mm 24 po x 28 po Coupez et retirez seulement les bardeaux qui se trouvent l int rieur de ce rectangle 4 Mesurez et tracez un ORIFICE D UN DIAMETRE DE 279 MM 11 PO et un ORIFICE D UN DIAMETRE DE 32 MM 1 PO D coupez ces orifices de part en part du mur PREPAREZ LE VENTILATEUR TOUTES LES INSTALLATIONS 1 D ballez l ensemble du ventilateur 2 Enlevez le couvercle et les vis 3 Enlevez et jetez le carton de la roue du ventilateur 4 Enlevez le couvercle de la bo te des fils et les vis 5 Attachez une pince de raccordement appropri e approuv e par l ACNOR dans le trou l arri re de la bo te des fils INSTALEZDUVENTILATEUR 1 Enlever les clous de toiture des deux tiers sup rieurs des tuiles autour de la partie coup e et soulever doucement les tuiles pour que la t le de revers du bo ter du ventilateur puisse se mettre sous celles l 2 Centrer l anneau du ventilateur dans le trou de 11 28cm en s assurant que le trou de 1 32mm de diam tre pour les fils lectriques soit align avec le trou du bo ter des fils lectriques 3 Attacher le ventilateur au toit au moyen des 6 vis fournies Les six trous du panneau arri re doivent tre bouch s sinon de l humidit pourra entrer dans le bo ter
3. PREPARE THE INSTALLATION LOCATION ROOF INSTALLATIONS WALL INSTALLATIONS 1 Locate the blower on the rear slope of the roof Place it in a location to minimize duct run The location should be free of obstacles T V leads electrical lines etc Bear in mind if the blower top is level with the roof peak it will not be seen from the street Keep this approximate location in mind as you work from within the attic REMOVE SHINGLES Pilot Hole v o o ra 74 OUTSIDE ROOF VIEW From inside the attic space 2 Drill a PILOT HOLE up through the roof 8 2 from the inside edge of a ROOF RAFTER From outside on the roof 3 Measure and mark the 20 x 20 2 rect angle Cut and remove only the shingles inside this rectangle 4 Measure and mark the 11 DIAMETER HOLE and the 1 DIAMETER HOLE Cut these holes all the way through the roof Figure 2 5 For flat roof installations build a curb that will mountthe blower ata minimum pitch of 2 12 See Figure 2 Discharge end of the blower should be pointed away from pre vailing winds 1 Choose a position on the outside wall Make sure that no wall studs pipes or wires run through the opening area REMOVE SIDING 11 dia a Hie P i Wall Stud 1 dia hole 1 o Wall Stud OUTSIDE WALL VIEW From inside the wall 2
4. la pared auna distancia de 21 6 cm 8 2 del borde interiorde un MONTANTE DE LAPARED Desde el exterior en la pared 3 Mida y marque el rect ngulo de 62 9 x 71 8 cm 24 x 28 Corte y quite s lo el forrado que se encuentra dentro de este rect ngulo 4 Mida y marque el ORIFICIO DE 27 9 CM 11 y el ORIFICIO DE 3 2 CM 1 1 4 de DIAMETRO Haga estos orificios totalmente a trav s de la pared PREPAREELVENTILADOR 1 Desempaque el conjunto del ventilador 2 Quite la cubierta y los tornillos 3 Quite y deseche el cart n de la rueda del ventilador 4 Quite la cubierta de la caja de conexiones y los tornillos 5 Coloque un conectador de cables apropiado aprobado por U L en el orificio que se encuentra en la parte posterior de la caja de conexiones INSTALE DEL VENTILADOR INSTALACIONES DE TECHO INSTALACIONES DE PARED ll Saque los clavos de techo de las 2 3 partes del revestimiento alredeador de rea del corte y cuidadosamente levante las tablillas para permitir que las tapajuntas de la caja del ventilador encajen debajo Centre el anillo del ventilador en el agujero de 28 cm cercior ndose que el agujero de 32 mm de di metro quede alineado con el agujero de la caja de conexiones Asegure el ventilador al techo con los seis tornillos provistos Todos seis agujeros del panel posterior deben sellarse o cualquier humedad que pudiera entrar en la caja podr tambi n infiltrarse en la ca
5. 98008510 99020263 99020264 99140145 99400055 99100517 99150471 99150535 99271110 DESCRIPTION Airbox Assembly Damper Sheet Metal Nut 8 18 U Type 7 req Isolator 3 req Whiz Nut 1 4 20 3 req Grille Heyco Damper 2 req Motor W Capacitor Model EB9 Motor W Capacitor Model EB6 Wiring Box Cover Capacitor Clamp Airbox Cover Blower Wheel Model EB9 Blower Wheel Model EB6 Damper Spring Heyco Foam Seal 4 req Hex Screw 10 32 x 1 2 Hex Screw 8 16 x 3 8 2 Req Capacitor 15 MFD Standard Hardware May be purchased locally Always order replacement parts by Part No not Key No A a Modelo EB6 Modelo EB9 Para el uso con las campanas compatibles de Best by Broan Vea el manual de la campana para la conveniencia BEST BY BROAN P O BOX 140 HARTFORD WI 53027 LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA Para reducir el riesgo de incendio des carga el ctrica o lesiones a personas cumpla los siguientes puntos 1 Solamente use esta unidad de la manera propuesta por el fabricante Si tiene alguna pregunta p ngase en contacto con el fabricante en la direcci n otel fono anotados en la garant a 2 Antes de limpiar o de poner en servicio la unidad apague el interruptor en el panel de servicio y asegure el panel de servicio para evitar que se encienda accidentalmente Cuando el dispositivo pa
6. cutting or drilling into wall or ceil INSTRUCTIONS ing do not damage electrical wiring or other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce risk of fire use only metal ductwork 8 This unit must be grounded CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive material and vapors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Please read specification label on prod uct for further information and require ments Electrical circuit including speed con trol if used must be rated 6 AMPS minimum for Model EB9 or 3 AMPS minimum for Model EB6 INSTALLER Leave This Manual With The Homeowner HOMEOWNER Use And Care Information On Page 4 SPECIFICATIONS MODEL VOLTS AMPS CFM DUCTSIZE 10 DIA 10 DIA PLAN THE INSTALLATION ALL INSTALLATIONS 1 Locate the blower so the length of the duct run and number of elbows are kept to a minimum 2 Where possible blower should be cen tered between wall studs or roof rafters PLAN THE INSTALLATION 3 Avoid pipes wires or other ductwork that may be running through the wall 4 Attach mounting plate to top of hood 5 Install 10 dia ductwork and 120 VAC house wiring between blower location and hood location PREPARE THE INSTALLATION LOCATION
7. ducto No debe haber obstaculos Alambres de T V l neas el ctricas etc Tenga en cuenta que sieltope del ventilador est anivel de la c spide deltecho no se lover desdelacalle Recuerde la ubicaci n aproximada mientras trabaja en el tico pl 527 mm Fig ra 1 1 Escoja un sitio en la pared exterior Cerci rese que no hay montantes tuber a o alambres en dicho punto Figura 3 628 7mm meno plg 184mm C40 EXTERIOR VISTA DEL TECHO Desde el interior del espacio del tico 2 Haga un ORIFICIO PILOTO atrav s del techo auna distancia de 21 6 cm 8 Y del borde interiorde una VIGA DEL TECHO Desde el exterior en el techo 3 Mida y marque el rect ngulo de 52 7x52 1 cm 20 x 20 12 Corte y quite s lo las tejas que se encuentran dentro de este rect ngulo 4 Mida y marque el ORIFICIO DE 27 9 CM 11 y el ORIFICIO DE 3 2 CM 1 1 4 de DIAMETRO Haga estos orificios totalmente atrav s deltecho 1715mm 6 plg 5 Para instalar un ventilador sobre un techo plano construya un bastidorpara soportar el ventilador con una pendiente m nima de 2 12 Elextremo de descarga del ventilador debe apuntar en direcci n contraria a los vientos dominantes pared Montante de la EXTERIOR VISTA DELAPARED Desde el interior de la pared 2 Haga un ORIFICIO PILOTO atrav s de
8. et passer dans la maison 4 Gr ce du ciment pour toit de bonne qualit rendre tanches les tuiles autour de bo ter etde la t le du ventilateur ainsi que les t tes de vis d attache de celui l 5 Faire passer les fils lectriques de la hotte dans le trou du bo tier de fils lectriques et l attacher en suivant les r glements locaux Figure 4 BLANC AU BLANC VERT AU VERT C BLAGE 126 V C A DE LA HOTTE 6 Faire les raccords lectriques avec le connecteur qui convient pour le genre de fil utilis Relier le blanc au blanc le noir au noir et le vert ou le fil d nud au vert Voir la figure 4 ainsi que l tiquette du fil sur la plaque de montage de la hotte 7 Remetre le couvercle et les vis du boiter de fils lectriques Ne pas pincer les fils sous le couvercle 8 V rifier que le registre se meut bien librement avant de remettre le couvercle et les vis du boiter 9 Mettre sous tension et v rifier le fonctionnement du ventilateur INSTALEZDUVENTILATEUR 1 Placer un large cordon de calfatage a l arri re du boiter le long du bord ext rieur 2 Centrer l anneau du ventilateur dans le trou de 11 28cm de diam tre en s assurant que le trou de 114 32mm de diam tre pour les fils lectriques soit align avec le trou du boiter des fils lectriques 3 Attacher le ventilateur au mur au moyen des 6 vis fournies Les six trous du panneau arri re doivent tre bouch s
9. other than by Broan faulty installation or installation contrary to recommended installation instruc tions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN S OBLIGATION TO REPAIR OR REPLACE AT BROAN S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CON NECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original pur chase date Best by Broan P O Box 140 Hartford WI 53027 SERVICE PARTS MODELS EB6 amp EB9 16 97011795 98008507 93260454 99100484 99260477 98008511 99100379 99080396 99080397 98008509 98008588
10. Drill a PILOT HOLE through the wall 812 from the inside edge of a WALL STUD From outside on the wall 3 Measure and mark the 24 x 284 rectangle Cut and remove only the sid ing inside this rectangle 4 Measure and mark the 11 DIAMETER HOLE and the 14 DIAMETER HOLE Cut these holes all the way through the wall PREPARE THE BLOWER ALLINSTALLATIONS 1 Unpackthe blower assembly 2 Remove the cover and screws 3 Remove and discard cardboardfrom blower wheel 4 Remove the wiring box cover and screws 5 Attach an appropriate U L approved cable connectorin the hole atthe rear ofthe wiring box INSTALL THE BLOWER ROOF INSTALLATIONS 1 Remove roofing nails from the upper 2 3 of the shingles around the cutout area and carefully lift the shingles to allow the back flashing sheet on the blower hous ing to fit under them 2 Center the blower ring in the 11 diam eter hole making sure that the 1 1 4 diameter electrical wiring hole aligns with the hole in the wiring box 3 Attach the blower to the roof with the six screws provided All six holes in the back panel must be filled or any moisture that may get inside the housing could leak into the house 4 Using a good grade of roofing cement seal all of the shingles around the hous ing and flashing sheet as well as the mounting screw heads 5 Bring electrical wiring from hood through the hole in the wiring box and secure it according to local c
11. ENDRA PAS RESPONSABLE DES DOMMAGES DIRECTS INDIRECTS OU SPECIAUX SURVENENT A CAUSE DE OU EN RAPPORT A L UTILISATION OU LA PERFORMANCE DE SES PRODUITS Certains tats et certaines provinces ne permettent pas l exclusion ou le limitation des dommages directs ou indirects la limitation ou l exclusion ci dessus peut donc ne pas s appliquer vous Cette garantie vous donne des droits l gaux sp cifiques et il se peut que vous ayez d autres droits qui varient d un tat a un autre et d une province a une autre Cette garantie annule toutes les garanties pr c dentes Pour le service sous garantie vous devez a aviser Broan l adresse ou num ro de telephone ci dessous b donner le num ro du mod le et l identification de la pi ce et c d crire la nature de tout d faut dans le produit ou la pi ce Au temps de demander la service sous garantie vous devez pr senter une preuve de la date d achat original Best by Broan P O Box 140 Hartford WI 53027 17 PI CES D TACH ES MOD LES EB6 amp EB9 16 97011795 Ensemble Boiter Air 98008507 Registre 93260454 Ecrou t le 8 18 Type U 7 n c 99100484 Isolant 3 n c 99260477 Ecrou Whiz 4 20 3 n c 98008511 Grille 99100379 Registre Heyco 2 n c 99080396 Moteur avec condesateur Mod le EB9 99080397 Moteur avec condesateur Mod le EB6 98008509 Couvercle de bo ter de fils lectriques 98008588 Serre joint de condensate
12. NDIMIENTO DEL PRODUCTO Algunos estados no permiten la exclusi n olimitaci n de da os accidentales o consiguientes porlo que la limitaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar en el servicio de garant a usted debe a notificar a Broan al domicilioo o al n mero de telefono abajo b dar el n mero del modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar servicio cubierto por la garant a usted debe presentar evidencia de la fecha original de compra Best by Broan P O Box 140 Hartford WI 53027 11 PARTES DE SERVICIO MODELOS EB6 amp EB9 16 97011795 98008507 93260454 99100484 99260477 98008511 99100379 99080396 99080397 98008509 98008588 98008510 99020263 99020264 99140145 99400055 99100517 99150471 99150535 99271110 Conjunto Aireador Registro Tuerca para Chapa 8 18 Tipo U se nec 7 Aislante se nec 3 Tuerca Rapida 1 4 20 se nec 3 Rejilla Registro Heyco se nec 2 Motor con Condensador Modelo EB9 Motor con Condensador Modelo EB6 Tapa Caja de Conexiones Grapa de Condensador Tapa de Aireador Rodete de Ventilador Modelo EB9 Rodete de Ventila
13. amper before installing housing cover and screws 9 Turn on power and check operation of the blower 10 Top and side flanges of the back plate may be covered with trim strips Do not block grille opening at bottom with trim It will adversely affect performance of the blower USE AND CARE Disconnect electrical power supply and lock out service panel before cleaning or servic ing this unit CLEANING Remove cover and carefully vacuum blower and inside of housing Be careful not to bend or otherwise damage blower wheel MOTOR LUBRICATION The motor is permanently lubricated Do not oil or disassemble motor WARRANTY BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRAN TIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP START ERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair
14. bremente antes de poner la tapa y los tornillos 9 Prenda la electricidad y verifique el funcionamiento del ventilador 10 Las bridas del tope y los costados de la plancha trasera pueden cubrirse con tiritas de guarnici n No bloquee la entrada de la rejilla con la parte baja de la guarnici n Afectar grandemente el rendimiento del ventilador que est usando Conecte el cable blanco con el blanco el negro con el negro y el verde o alambre desnudo con el verde Consulte la Figura 4 y la etiqueta de cableado que se encuentra en la placa de montaje de la campana Reemplace la tapa de la caja y tornillos No apriete el alambre bajo la tapa Verifique que el registro se mueve libremente antes de poner la tapa y los tornillos Prenda la electricidad y verifique el funcionamiento del ventilador USO Y CUIDADO Desconecte la fuerza el ctrica y bloquee el panel de servicio antes de limpiar o hacer el servicio en la unidad LIMPIEZA Saque la tapa y con cuidado limpie con la aspiradora el ventilador y el interior de la caja Tenga cuidado de no torcer o causar da o a los rodetes del ventilador LUBRICACION DEL MOTOR El motor tiene lubricaci n permanente No lo enaceite o desarme 10 GARANTIA GARANTIA BROAN LIMITADA POR UN ANO Broan garantiza al consumidor comprador original de sus productos que dichos productos carecer n de defectos en materiales o en mano de obra por un periodo de un a o a partir
15. de la fecha original de compra NO EXISTEN OTRAS GARANTIAS EXPRESAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANT AS IMPL CITAS DE COMERCIALIZACI N O APTI TUD PARA UN PROPOSITO PARTICULAR Durante el per odo de un a o y a su propio criterio Broan reparar o reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso ESTA GARANT A NO SE APLICA A TUBOS Y ARRANCADORES DE L M PARAS FLUORESCENTES Esta garant a no cubre a mantenimiento y servicio normales o b cualquier producto o piezas que hayan sido utilizadas de forma err nea negligente que hayan causado un accidente o que hayan sido mantenidas o reparadas inapropiadamente por otras compa as que no sea Broan instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la limitacion antes mencionada puede no aplicarse a usted LA OBLIGACI N DE BROAN DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DE BROAN DEBER SER EL UNICO Y EXCLUSIVO RECUR SO LEGAL DEL COMPRADOR BAJO ESTA GARANT A BROAN NO SERA RESPONSABLE POR DA OS ACCIDENTALES CONSIGUIENTES O POR DA OS ESPECIALES SURGIDOS O EN CONEXI N CON EL USO O EL RE
16. dor Modelo EB6 Resorte de Registro Heyco Sellante de Espuma se nec 4 Tornillo Hexag 10 32 x 1 2 Tornillo Hexag 8 16 x 3 8 se nec 2 Condensador 15 MFD Tornilleria estandar Pueden comprarse localmente Siempre pida repuestos dando el No de Parte No la Clave 12 Mod le EB6 Mod le EB9 Pour utilisation avec les hottes compatibles de Best by Broan Voir le manuel de la hotte pour la convenance BEST BY BROAN P O BOX 140 HARTFORD WI 53027 LIRE ET CONSERVER CES INSTRUCTIONS AVERTISSEMENT POUR REDUIRE LES RISQUE D INCENDIE D LECTROCUTION OU DE BLESSURES CORPORELLES OBERVEZ CE QUI SUIT fi N utilisez cet appareil que selon la mani re pr vue par le fabricant Si vous avez des questions contactez le fabricant l adresse ou au num ro de t l phone indiqu e dans la garantie Avant de r parer ou denettoyerl appareil teindre ce dernier au panneau de ser vice afin d viter sa remise en marche accidentelle Sile panneau de service ne peut tre verrouill y fixer un avertissement en vidence Letravail d installation et de branchement des fils lectriques doit tre effectu par une ou des personnes qualif es selon tous le codes et toutes les normes en vigueur y compris ceux et celles concernant les constructions talonn es contre le feau ll faut suffisamment d air pour qu une bonne combustion et un bon chapp
17. ement des gaz se produisent par le conduit de chemin e de l equipement pour emp cher un refoulement d air Suivre les suggestions et les normes de s curit du tabricant de l quipement de chauffage telles que celles publi es par le NFPA Association Nationale de Pro tection contre le Feau et L ASHRAE Soci t am ricaine des ing nieurs du chauffage de la r frig ration et de la climatisation et les autorit s localaes en mati re de normes AVERTISSEMENT 5 Lorsque vous coupez dans un mur ou 6 7 8 loursque vous le percez ne pas endommager les fils lectiques et les autres l ments utilitaires quis y touvent Les ventilateurs conduit doivent toujours avoir leu sortie l ext rier Pour r duire le rissque d incendie n utiliser que des conduits en acier Cet appareil doit tre reli terre ATTENTION f 2 4 A mutiliser que pour une ventilation g n rale Ne pas utiliser pour vacuer des mat riaux et des vapeurs dangeuses ou explosives Pour viter des d g ts aux roulements du moteur et aux h lices du ventilateur bruyantes et ou d s quilibr es viter de pulv riser les pl tres pr s de l appareil et de contaminer celui ci avec de la poussi re etc Veuillez lire l tiquette de sp cifications se trouvant sur le produit pour de plus amples infonnations et exigences Le circuit lectrique comprenant le contr le de vitesse si celui ci utilis doit
18. i d monter le moteur 16 GARANTIE LIMIT E D UN AN DE BROAN Broan garantit l acheteur consommateur original de ses produits qu ils sont exempts de d fauts dans les mati res premi res ou la main d oeuvre pour une p riode d un an compter de la date d achat original IL N Y A PAS D AUTRES GARANTIES EXPRIMEES OU IMPLICITES INCLUANT LES MAIS NON PAS LIMIT ES AUX GARANTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE DANS UN EUT PARTICULIER Pendant oette p riode d un an Broan son choix r parera ou remplacera gratuitement tout produit ou pi ce qui s av re d fectueux sous utilisation et service normaux CETTE GARANTIE NE COUVRE PAS LES STARTERS DE LAMPES FLUORESCENTES ET LES TUBES Cette garantie ne couvre pas a l entretien et le service normaux ou b tout produit ou pi ce endommag par suite de mauvais usage n gligence accident entretien inappropri ou r paration autre que par Broan mauvaise installation ou installation contraire au mode d installation recommand La dur e de toute garantie implicite est limit e une p riode d un an tel que sp cifi pour la garantie exprim e Certains tats et certaines provinces no permettent pas la limitation de la dur e d une garantie implicite la limitation ci dessus peut dono ne pas s appliquer vous L ENGAGEMENT DE BROAN DE R PARER OU DE REMPLACER AU CHOIX DE BROAN SERA LA SEULE OBLIGATION EXCLUSIVE SOUS CETTE GARANTIE BROAN NE SE TI
19. odes Figure 4 120 VAC WIRING FROM HOOD 6 Make the electrical connections with the proper connector for the type of wiring being used Connect white to white black to black and the green or bare wire to green See Figure 4 as well as the wiring label on the hood s mounting plate 7 Replace wiring box cover and screws Do not pinch wiring under the cover 8 Check for free movement of the damper before installing housing cover and screws 9 Turn on power and check operation of the blower INSTALL THE BLOWER WALL INSTALLATIONS 1 Place a large bead of caulk on the back side of the housing along the outer edge 2 Center the blower ring in the 11 diam eter hole making sure that the 1 1 4 diameter electrical wiring hole aligns with the hole in the wiring box 3 Attach blower to the wall with the six screws provided All six holes in the back panel must be filled or any moisture that may get inside the housing could leak into the house 4 Using a good grade of caulk seal all around the mounting screw heads 5 Bring electrical wiring through the hole in the wiring box and secure it according to local codes 6 Make the electrical connections with the proper connector for the type of wire being used Connect white to white black to black and green or bare wire to green See Figure 4 7 Replace wiring box cover and screws Do not pinch wiring under cover 8 Check for free movement of the d
20. ra desconectar el servicio el ctrico no puede ser cerrado con alg n tipo de traba sujete fuertemente al panel de servicio una etiqueta de advertencia prominente 3 El trabajo de instalaci n y el alambrado el ctrico deben llevarse a cabo por per sonal calificado de acuerdo con todos los c digos y las normas aplicables incluyendo los c digos y normas de con strucci n contra incendios 4 Se requiere una cantidad de aire sufici ente para la combusti n y escape de gases por la chimenea del equipo de quemado de combustible para evitar salirse de las especificaciones y est n dares de seguridad del fabricante tales como los publicados por la Asociaci n nacional de protecci n contra incendios NFPA por sus siglas en Ingl s y la Sociedad americana de ingenieros de calefacci n refrigeraci n y aire acondi cionado ASHRAE por sus siglas en In gl s y los c digos de las autoridades locales ESPECIFICACIONES ADVERTENCIA 5 Cuande corte o taladre en una pared o techo no da e los cables el ctricos ni otras instalaciones ocultas 6 Los ventiladores con ductos siempre deben de ventilar hacia el exterior 7 Para reducir el riesgo de incendio use solamente conductos de metal 8 Esta unidad se debe conectar a tierra PRECAUCION 1 S lo para uso de ventilaci n general No se use para extraer materiales o vapores peligrosos o explosivos 2 Para evitar da os al cojinete del motor y o impulsores ruidoso
21. s o desequilibra dos mantenga la fuente de potencia lejos de roc os de pared seca de polvo de construcci n etc 3 Lea la etiqueta de especificaciones en el producto para mayor informaci n y req uisitos 4 El circuito incluyendo el control de la velocidad si lo usa debe tener capacidad de 6 AMPS m nimo para el Modelo EB9 o 3 AMPS m nimo para el Modelo EB6 INSTALADOR Deje este manual con el usuario USUARIO Uso y informaci n sobre el cuidado en la p gina 4 MODELO voLTIOS amps CFM TAMA O DUCTO EB6 120 2 4 600 25 cm de DIA EB9 120 5 7 900 25 cm de DIA PLANEAMIENTO DE LA INSTALACION TODAS LAS INSTALACIONES 1 Ubique el ventilador de manera que la longitud del ducto y el numero de codos se reduzcan al minimo 2 Cuando sea posible el ventilador deber centrarse entre los montantes de la pared o las vigas del techo PLANEAMIENTO DE LA INSTALACION 3 Evite tubos cables u otros ductos que puedan estar tendidos a lo largo de la pared 4 Conecte la placa de montaje en la parte superior de la campana 5 Instale un ducto de 10 de di metro y cables dom sticos de 120 VCA entre la ubicaci n del ventilador y la ubicaci n de la campana PREPARE EL SITIO PARA LA INSTALACION _ _ __ _ PREPARE EL SITIO PARA LA INSTALACION _ __ _ INSTALACIONES DE TECHO INSTALACIONES DE PARED 1 Coloqueelventiladoren la gradientetrasera deltecho Ubiqueloenlugarquenorequiera largo
22. sa Usecemento paratecho de buena calidad para sellar todas las tablillas alrededor de la caja y el tapajuntas asi como tambi n las cabezas de los tornillos Pase los cables el ctricos desde la campana a trav s del agujero de la caja y aseg relos de acuerdo con los c digos locales Figura 4 CABLES DE 120 VCA DESDE LA CAMPANA BLANCO VERDE A BLANCO VERDE Haga las conexiones el ctricas con el conector apropiado para el tipo de cables INSTALE DEL VENTILADOR 1 Ponga una gota gruesa de masilla de calafateo en la parte posterior de la caja a lo largo del borde exterior Centre el anillo del ventilador en el agujero de 28 cm de di metro queda alineado con el agujero de la caja Asegure el ventilador a la pared con los seis tornillos provistos Todos seis agujeros del panel posterior deben sellarse o cualquier humedad que pudiera entrar en la caja se infiltrar en la casa Use una masilla de calafateo de calidad para sellar bien alrededor de las cabezas de los tornillos de montaje Pase el alambre el ctrico por el agujero en la caja y aseg relo de acuerdo con los c digos locales Haga las conexiones el ctricas con el conector apropiado al alambre que emplea Conecte blanco a blanco negro a negro y verde o alambre desnudo a verde Vea la Figura 4 Reemplace la tapa de la caja y tornillos No apriete el alambre bajo la tapa Verifique que el registro se mueve li
23. si le dessus du ventilateur est ras de la pointe du toit il ne sera pas vu de la rue Souvenez vous de cet emplacement approximatif pendant que vous travaillez de l int rieur de l entre toit Lam coven TT diam trede PR PARATIONDE L EMPLACEMENTPOUR LINSTALLATION 1 Choisissez une position surle mur ext rieur Assurez qu il n y a pas de colombage tuyaux ou fils dans l endroit qui sera ouvert ILLUSTRATIONS 29mm TT evo EXT RIEUR VUE DU TOIT De l int rieur du grenier 2 Percez un AVANT TROU travers le toit une distance de 216 mm 8 po du rebord int rieur d un CHEVRON De l ext rieur sur le toit 3 5 Mesurez et tracez un rectangle de 527 mm x 521 mm 20 po x 20 po Coupez et retirez seulement les bardeaux qui se trouvent l int rieur de ce rectangle Mesurez et tracez un ORIFICE D UN DIAM TRE DE 279 MM 11 PO et un ORI FICE D UN DIAMETRE DE 32 MM 1 4 PO D coupez ces orifices de part en part du toit 51mm 2 po ILLUSTRATION2 gt 1715mm Pour les installations sur les toits plats fabriquez une bordure qui inclinera le ventilateur de 2 12 au minimum Voir ill 2 L extr mit de la d charge du ventilateur doit pointer du c t oppos aux vents dominants 45 EXT RIEUR VUE DU MUR De l int rieur du mur 2 Percez un AVANT TROU
24. sinon de l humidit pourra entrer dans le vo tier et passer dans la maison 4 Grace un calfatage de qualit rendre tanche tout autour des t tes de vis d installation du ventilateur 5 Faire passer les fils lectriques dans le trou du bo ter de fils lectriques et l attacher en suivant les reglements locaux 6 Faire les raccords lectriques avec le connecteur qui convient pour le genre de fil utilis Relier le blanc au blanc le noir au noir et le vert ou le fil d nud au vert Voir la figure 4 7 Remettre le couvercle et les vis du boiter de fils lectiques Ne pas pincer les fils sous le couvercle 8 V rifier que le registre se meut librement avant de remettre le couvercle et les vis du bo ter 9 Mettre sous tension et v rifier le fonctionnement du ventilateur 10 Les rebords due haut et des c t s de la plaque arri re doivent tre couvertes avec des bordures en bois Ne pas bloquer l ouverture de la grille en bas avec une bordure Cela risquerait d affecter les per formances du ventilateur USAGE ET ENTRETIEN D brancher le courant et le panneau de ser vice avant de nettoyer ou d effectuer une r paration ou un entretien dans ce ventilateur NETTOYAGE Enlever le couvercle passer soigneusement l aspirateur Veillez ne pas plier ou endommager d une mani re quelconque la roue du ventilator LUBRIFICATION DU MOTEUR Le moteur est lubrifi en permanence Ne pas graisser n
25. tre talonn 6 AMPERES minimum pour le mod le EB9 ou 3 AMPERES minimum pour le mod le EB6 INSTALLATEUR Donner ce manuel au propri taire PROPRIETAIRE DE LA MAISON Information d usage et d entretien la page 3 SP CIFICATIONS MOD LE VOLTS AMPERES CFM DIMENSIONS DES CONDUITES _ DE DIAMETRE 10 25cm DE DIAMETRE EB6 120 2 4 600 EB9 120 5 7 900 PLANNIFICATIONDEL INSTALLATION TOUTES LES INSTALLATIONS Placer le ventilateur de telle sorte que la longueur des conduites et le nombre de coudes et transitions soient gard s au mini mum Chaque fois que possible le ventilateur doit tre centr entre les poutres du mur ou les chevrons du toit 10 25cm PLANNIFICATIONDEL INSTALLATION 3 viter les tuyaux les fils lectriques ou autre conduites qui se trouveraient dans le mur 4 Fixer la plaque de montage sur le dessus de la hotte 5 Installer un syst me de gaines de 10 pouces de diam tre et des fils r sidentiels de 120 v c a entre l emplacement du ventilateur et celui de la hotte PR PARATIONDE L EMPLACEMENTPOUR L INSTALLATION i SUR LE TOIT INSTALLATION SUR UN MUR ILLUSTRATION1 597mm Positionnezle ventilateur sur la pente arri re du toit Placez le dans un endroit qui minimisera la longueur du conduit de ventilation Cet endroit doit tre exempt d obstacles c ble de t l viseur lignes lectriques etc Souvenez vous que
26. ur 98008510 Couvercle de bo ter air 99020263 Roue de ventilateur Mod le EB9 99020264 Roue de ventilateur Mod le EB6 99140145 Ressort de registre 99400055 Heyco 99100517 Joint en mousse 4 n c 99150471 Vis t te hex 10 32 x Y2 99150535 Vis t te hex 8 16 x 3 8 2 n c 99271110 Condensateur 15 MFG Hardware standard Peut tre achet localement Toujours commander des pi ces d tach es par leur NO DE PIECES et non par le NO D ENTR E 18 19 99042680D