Belkin Frozen Dessert Maker belkin bulldog plus- User's Manual

image

Contents

1. Battery Voltage Battery Current Battery Level Input x 1 02 25 2002 16 50 27 2 100 0 60 0 2 02 26 2002 14 30 27 2 100 0 60 0 3 02 26 2002 14 31 27 2 100 0 60 0 4 02 26 2002 14 32 27 2 100 0 60 1 5 02 26 2002 14 33 27 2 100 0 60 0 6 02 26 2002 14 34 27 2 100 0 60 0 ti 02 26 2002 14 35 27 2 100 0 59 9 8 02 26 2002 14 36 27 2 100 0 60 0 9 02 26 2002 14 37 27 2 100 0 60 0 10 02 26 2002 14 38 27 2 100 0 60 0 11 02 26 2002 14 39 27 2 100 0 60 0 02 26 2002 27 2 100 0 60 0 M a Select Month Displays the UPS data in the month which you want to see b Update Updates the list c Save As Saves the data in the list format to the file that you assigned d Print Exports the list data to a printer e Exit Closes the history data dialog box Auto Save When certain power events occur Bulldog Plus will save open files and close applications before shutting down the operating system If these saved files are untitled Bulldog Plus will assign file names for them and Belkin Components 39 put the files in temporary directory This dialog box will tell you which files were saved by Bulldog Plus a Program Title The application s title name b Auto Save File Name Bulldog Plus names the file for you c Clear Clear this record Remote Hosts Detects the hosts which are running the Bulldog Service in the LAN You can also type in the IP address and connect to the WAN R
2. Countdown to UPS i iShutdown UPS viKUPS Restart to Tum PC on If you enable this function the UPS will reboot to restart the computer otherwise it goes back to its normal state Enable Economic Mode Switches to UPS economic mode UPS Periodic Auto Test Daily weekly biweekly and monthly UPS starts the test procedure automatically when it reaches the test time Belkin Components 29 Network Network Set Password Master Slave Remote Wakeup SNMP ETIES Set Password Sets the Bulldog Service password Choose Master Slave Please refer to the BULLDOG Service operation mode If the computer connects to UPS directly with RS 232 or USB and can send commands to its connected UPS then the BULLDOG Service acts as a Master If it connects to UPS directly with RS 232 or USB but only listens to UPS then it is a Serial Slave If the computer is powered by the UPS but obtains the UPS information from Master via TCP IP network then it is a Networking Slave When BULLDOG Service is a Networking Slave you must assign the Master IP address so that the Networking Slave can connect to the Master and obtain the UPS information a Master Configures the BULLDOG Service to be a Master b Serial Slave Configures the BULLDOG Service to be a Serial Slave c Networking Slave Configures the BULLDOG Service to be a Networking Slave d Master IP Address When BULLDOG Service is a Networking Slave you must assig
3. Transfer Voltage Changes the low transfer voltage and high transfer voltage This function lets your UPS adjust to the local power environment a Low Transfer Voltage When utility power voltage drops lower than the assigned value the UPS will switch to backup mode The output power is supplied from the battery b High Transfer Voltage When utility power voltage rises higher than the assigned value the UPS will switch to backup mode The output power is supplied from the battery Belkin Components 28 Advanced UPS Property Iv Enable Wakeup Computer Iv Enable Resume Computer Enable Power Fail Auto Reboot Enable Economic Mode UPS Periodic Auto Test Biweekly v Set Default Cancel If your UPS doesn t support this function the item will be displayed as gray and the user cannot select this item Enable Wakeup Computer If your computer architecture is compatible to ATX and the BIOS supports RS 232 RI Wakeup function You should enable this item to make the Schedule work correctly Enable Resume Computer Be sure the BIOS supports RS 232 RI Wakeup function When Bulldog Plus suspends the computer and the UPS detects the change of power status the UPS will resume the computer to its prior operating status and let Bulldog Plus notify users Enable Power Fail Auto Reboot The time line describes below Power Restore Input Power iCountiown to Shutdown PC Computer Shutdown PC
4. NN10 6GL United Kingdom Tel 44 0 1933 35 2000 Fax 44 0 1933 31 2000 France Belkin SAS Components 5 rue du Petit Robinson 78 350 Jouy en Josas France Tel 33 0 1 34 58 14 00 Fax 33 0 1 39 46 62 89 Germany Belkin Components GmbH Hanebergstrasse 2 Belkin Components 43 80637 M nchen Germany Tel 49 0 89 143405 0 Fax 49 0 89 143405 100 The Netherlands Belkin Components B V Starparc Building Boeing Avenue 333 1119 PH Schiphol Rijk e The Netherlands Tel 31 0 20 654 7300 Fax 31 0 20 654 7349 European Customer Service Sales 00 800 223 55 460 eurosales belkin com European Tech Support 00 800 223 55 460 eurosupport belkin com Australia Belkin Ltd 7 Bowen Crescent West Gosford NSW 2250 Australia Tel 61 0 2 4372 8600 Fax 61 0 2 4372 8603 Tech Support Australia Toll Free 1800 666 040 New Zealand Toll Free 0800 441 913 Singapore Toll Free 800 6161 790 belkin com anz China Belkin Shanghai Representative Office Suite 31 39 F Plaza 66 1266 Nanjing West Road Shanghai 200040 China Tel 8621 62881747 Fax 8621 62881748 Belkin Components 44 Customer Service Sales china belkin com Tech Support 800 820 5816 Belkin Components 45
5. Next Battery Replacement Date To change the date of next battery replacement in the System gt Configuration UPS gt UPS Property Next 10 seconds Test Time System gt Configuration UPS gt Schedule Next Deep Test Time System gt Configuration UPS gt Schedule Next Shutdown UPS Time system Configuration UPS gt Schedule Next Restart UPS Time System gt Configuration UPS gt Schedule Status Shows all of the UPS statuses red light indicates this event happened Diagram Input and output power flow of UPS Scroll Records the most recent UPS data information You can change the displayed item from System gt Main Screen Outlet Displays the UPS outlet status If your UPS cannot control the outlet this button disappears Status Identifies the current outlet status Normal or shut Next Turn Off Time System Configuration UPS Schedule Next Turn On time System Configuration UPS Schedule Network Displays all the Bulldog Services searched in the LAN Belkin Components 42 Service and Support Corporate Headduarters Belkin Corporation 501 West Walnut Street Compton CA 90220 5221 e USA Tel 310 898 1100 Fax 310 898 1111 Customer Service Sales 800 2BELKIN 800 223 5546 Technical Support 310 898 1100 ext 2263 800 223 5546 ext 2263 Fax 310 604 2089 techsupp belkin com belkin com support tech United Kingdom Belkin Components Ltd Express Business Park Shipton Way Rushden
6. located here c Port Number The default port number is 80 but if there is already one WEB server running you can change Bulldog Service HTTP port number to a different number At the Internet Browser you can input http 172 16 176 141 2000 in the URL where 2000 is the assigned port number Belkin Components 34 Shutdown Now Shutdown Now P BIBERISETISS Only This command will execute the shutdown procedure at once a Restart This function lets you restart the UPS automatically after being shutdown To start the UPS for the next schedule mark the Restart check box b Shutdown OS and UPS Use this function to shutdown both the OS and UPS c SHUTDOWN OS Only Use this function to shutdown OS only d SUSPEND OS Only Use this function to suspend your operating System e HIBERNATE OS Only Use this function to hibernate your operating System Cancel Shutdown This menu enables you to terminate the current shutdown procedure Belkin Components 35 Ga Turn Receptacle Relay On Turns the selected receptacle relay on Each Receptacle Relay may control more than one outlet please see the rear panel of your UPS or the UPS hardware user s manual a Select a Receptacle Relay Selects a receptacle relay b Delay Set the delay time to turn on the receptacle relay c On Executes the stated command Turn Receptacle Relay Off Turns the receptacle relay off Each Receptacle Relay may control
7. Help a Ki RI Configure Meters EventLog History Host Selection Locsl tnsofzcm 172 16 176 141 Model GES651V110100 OS Windows 98 D Host tnengkzl 172 16 176 100 Model Unknown OS Windows 98 A UPS Health Host sun rspare 172 16 176 144 Model GES651 110100 OS SunOS 5 5 1 zs 172 16 176 106 Seen OS Windows 98 A Host hpups 172 16 176 147 Mode Ca 2000 OS HP UX B1020 Host scok6 delta tw 172 16 176 154 Model BUIO0XR 2000 OS SCO SY 3 If the host is located on the Internet you can also input the remote host IP address from the View Menu Remote Hosts menu shows the hosts you can establish connections with Remote Hosts JB Host tnengfwm 172 16 176 129 Model Unknown OS Windows 98 A 4 B Host sun ultral 172 16 176 145 Model Unknown OS SunOS 5 5 1 B Host sun sparci 172 16 176 144 Model GES651V110100 OS SuNOS 2 Host upsweb 172 16 176 153 Model BU100XP 2000 OS Linux 2 2 ES Host scok6 delta tw 172 16 176 154 Model BU1OOXR 2000 OS B Host hpups0 172 16 176 147 Model BU100XR 2000 OS HP U B Host upsweb2 172 16 176 155 Model BU100XR 2000 OS Linu B Host tnpe 172 16 176 135 Model Unknown OS Windows 98 A m TA Uoot monadm 172 1E 176 117 Madal CCENT NE Mindaour no C Connect To This IP Address Remote Monitoring and Control Using Internet Browser Another way to remote monitor Bulldog Service is by using the Internet Browser Launch the Microsoft Internet Explorer or Netscape Belkin Components 12
8. Uninterruptible Power Supply UPS Bulldog Plus is designed to provide end users the ability to take proactive steps to protect their equipment from power related damages Bulldog Plus allows for automatic shutdowns scheduled shutdowns and a variety of other features that help you manage your system and its peripheral components Bulldog Plus provides detailed information about the UPS and its protected equipment It is easy to install and program yet has the necessary features to handle all of one s power requirements Included is the capability for network management protocol SNMP Bulldog Plus will disseminate UPS information into SNMP protocol and project it to the appropriate Network Management Station NMS such as HP OpenView To make use of resources on the Internet Bulldog Plus also supports HTTP protocol This enables end users to monitor their UPS anywhere anytime by simply utilizing their web browser Bulldog Plus runs in the background as a Windows service and communicates with the UPS in order to ensure that your computer and attached components are protected from any power problems Bulldog Plus features 1 Graceful operating system shutdown 2 Scheduled tests shutdown restarts of the UPS turn on off receptacles 3 Flexible events 4 Notification Pager e mail and audible alarm network broadcasting and SNMP 5 Real time values of voltage current frequency and loading 6 Historical data amp graph 7 Network m
9. more than one outlet please see the rear panel of your UPS or the UPS hardware user s manual a Select a Receptacle Relay Selects a receptacle relay b Delay Set the delay time to turn off the outlet group c Off Executes the turn off command UPS Audible Alarm On Enables the UPS buzzer On the Bottom Layer Buttons press the Status button to get the UPS buzzer status UPS Audible Alarm Off Mutes UPS buzzer alarm 10 Seconds Test UPS switches to backup mode and the output power is supplied by the battery for 10 seconds Deep Battery Test UPS switches to backup mode and output power is supplied by the battery until the battery is low Cancel Test This menu allows you to stop the test immediately Belkin Components 36 Meters Bulldog Plus supports up to 12 meters of real time values Each meter has the ability to display all of the UPS values Selecting different items from the Selection dialog box will display the selected item value BELKIN BULLDOG Plus Meters a 2 4 6 8 12 Displays meter number b Selection Assigns each meter to a different UPS item value c Close Closes the meter window Event Log This menu offers you the possibility of viewing past events Belkin Components 37 C BELKIN SENTRY BULLDOG Plus Event Log Pint m UPS communication established l gt Connect to UPS I gt UPS disconnect Cannot retrieve information from the UPS Load SENTRY BULLDOG Web
10. requested commands and set commands When you select the Accept SNMP packet from the following hosts Bulldog Plus receives information only from the hosts that you assigned Once a power event has occurred and the user enables the SNMP Trap in the Action dialog box Bulldog Plus will send the SNMP trap to the hosts that are listed in the Trap Target list box To add modify or delete the host click on its respective command button Port Number 161 x System Contact esse System Name Power UPS mE Accept SNMP packet from any hosts C Accept SNMP packet from the following hosts Add Modify Delete 172 16 176 141 172 16 176 142 private If you are using a Windows 2000 XP 2003 operating system you must install the SNMP Service and configure the SNMP parameters from your operating system Bulldog Plus will ignore the values that were set in the SNMP dialog box To change the parameters of SNMP function you should install the SNMP Service in the Network option Select the SNMP Service from the Network option in the Control Panel and click the Property button to do your changes Belkin Components 32 SNMP Trap Number Variable Trap No Description dupsCommunicationLost SEVER Communication with the UPS failed dupsCommunicationEstablished 2 INFORMATION Com
11. Attached Devices Allows the user to assign the attached device a name When you re controlling the outlet Bulldog Plus will let you know which devices you are controlling a Select an Outlet Group Assigns an outlet group Please look at the back panel carefully some outlets may share one control relay these outlets are called an outlet group If you turn off the outlet group for example outlet and outlet2 then the UPS will stop power to the outlet group outlet1and outlet2 b Device Name Assigns the attached devices a name for example Outlet Group is called Monitor for association with the monitor and Outlet Belkin Components 23 Group2 is called Computer for association with the CPU These records can improve the efficiency of your management Don t forget to press the Update button c Update Updates your change Log Management Please consider the free space in your hard disk a Maximum Event Log Entries Always Bulldog Plus to preserve less than the assigned entries of event log b Data Log Interval Time designated for automatic saving of a record of UPS data c Maximum Data Log Storage It allows you to save how many months UPS data files you wish to keep Schedule This function allows you to shutdown restart test and turn on off outlets You can schedule up to 6 events Settings are based on day week or month and up to a period of 2 years Choose the applicable schedule to set whether it be for a One Time
12. Belkin Bulldog Plus Shutdown Management Software for Windows User s Manual Table of Contents INTHODUGTION 15 33 funded telah E 5 plett 5 BULLDOG PLUS INSTALLATION ees ee sees ee RR anser KEN See EK ee ee NEGE 5 B lldog PIUS SD ai kw wA 6 BULLDOG PLUS SERVICE 7 BULLDOG PLUS MONITOR rtr see ee ee Ee Ee EE Ee XV Ee eN Ke we ER ES 9 NETWORKING ie ee EE 11 Operation Mode EE EE Ee mai eR a Tawa kaki 11 Remote Monitoring and Control 11 Remote Monitoring and Control Using Internet Browser 12 BULLDOG PLUS MONITOR OPERATIONS ccce 14 Top Layer BUHOfIS x od eid desine dente doit dede edente ebd ende 14 Bulldog Monitor Main Menu Ee Se Ge ee ee ique ete 15 KAS EO ER EN KA 16 Koo RE EE ac ela i ec cel EE ec 16 EE 17 POM e E 17 di ele EE n AE ED D IB Arn N n ID D IDA en DE 17 Close MORO E 18 CONFIGURATION WE 19 Gonfiguration WINAOW EE 19 DEVICES ciisciscscss E E 21 Modem cand NA SEER ARERI Notification Users Pager Let EEN 21 Notification Users email 21 Notifify Users Network Droadcast ee ee ee ee 21 COP E AA GE AE M dE 21 iol ate b Or 22 UPS gees 23 UPS e E 23 Attached Devi es keen EE ce EE 23 Oe MAMAG SING EE 24 soliede ss ee NNI ie oe ee ee se n ee oie RR 24 ele EE EE IE in EE nt ltd edet AAA KAA NA OE TO IA 25 Action eS OO WIS SR EE ha EE MU EL EE EE 26 Belkin Components 2 Action Broad
13. Communicator type the IP address in the URL and press enter You vent History Main Time Status Outlet Meters Log Data Configure Control Uiility Status UPS current status update every 30 seconds Normal will then be able to see the UPS information You can change the network port number to prevent conflict with other WEB server programs If the port number isn t 80 you have to type URL like this http 172 16 176 141 2000 where 2000 is the port number you assigned Belkin Components 13 Bulldog Plus Monitor Operations The Main Screen has 7 areas that present information on the operating status of your UPS These areas are discussed in the following sections BELKIN BULLDOG Plus Monitor Main Menu lt System Control View Wizard Help Top Layer Buttons lt oF 4 hllllu Configure Meters EventLog History Connection Host Selection Host Selection Local tnsofzcmn 17216176 141 Model GES651V110100 OS Windows98 v Listen UPS Health 2 www belkin com Test Result Test Passed UPS Type Line Interactive AC Source Normal Battery Status Normal Battery Level 100 UPS Model GES651 110100 Firmware Version 001 TT Host Name tisofzcm Information Display lt Rating V 650V EN zaji ID Rating Input roth 120V Input Voltagel Output Voltagel Rating Output Volt 1207 0 0 Rating Battery Volt 12V 45 P 135 45 YA 135 Rating In
14. DLL startup the Web servicel 13 36 49 Program startup a Print Prints the event log b Exit Closes event log dialog box History Graph Clicking on the History Graph opens a dialog box that contains information about the UPS data in graphical format This information is available only if there is an accumulation of data You can select the month and year you want to view History Graph x milin BELKIN SENTRY BULLDOG Plus History Graph Horizonal Scale 30 min v Select Month 2001 7 December Vestal Sal 55 J m Draw keral Blue Draw Ttem2 Red Input Voltagel Y Output Voltagel e 200 150 100 50 0 4 VW 5 0 30 5 11 00 A1 20 51200 5 12 30 5 13 00 5 13 30 5 14 00 5 14 30 5 15 00 Belkin Components 38 a Horizontal Scale Selects the time scale b Vertical Scale Selects the value scale c Select Month Displays the UPS data for the month which you want to see d Draw Item1 Blue Displays the UPS item value by a blue line e Draw Item2 Red Displays the UPS item value by a red line f Update Updates the graph g Print Exports the graph to a printer h Exit Closes the history graph dialog box History Data Clicking on the History Data opens a dialog box that contains information about UPS data in list format This information is available only if there is an accumulation of data You can select the month and year you want to
15. Module Bulldog Service which runs in the background as a Windows Service and communicates to the UPS e An User Interface Module Bulldog Monitor which enables you to control and configure Bulldog Plus through the drop down menus and dialog boxes It also allows you to monitor the UPS through the Main Screen Uninstall To remove Bulldog Plus from your hard disk Help Bulldog Plus on line help Bulldog Monitor User interface used to monitor and configure your UPS Bulldog Status Reflect the status of Bulldog Plus service program the service is used to communicate with your UPS Bulldog Plus Service Belkin Bulldog Service runs in the background as a Windows Service when the system initiates You can also run Bulldog Service manually by selecting the Start Menu Program Files Belkin Bulldog Bulldog Service Once Bulldog Service starts there is a Bulldog Service icon located on the system tray to indicate UPS status 1 Normal ER VE 17 39 PM Normal 2 UPS Disconnect cannot get any information from UPS ay 13 05 PM UPS Disconnect 3 Power Failed The UPS is operating on battery power ER 13 25 PM Power Failed 4 UPS Bypass Active ua 13 40 PM Bypass Moving your mouse over the Bulldog Plus icon in the system tray and click the right button to pop up the following menu v Show Countdown Monitor Configuration Meters Program Stop dug 08 50 AM e Show Countdown B
16. This set schedule is applicable for a single day b Daily This set schedule is applicable for every day c Weekly This set schedule is applicable for once a week period d Monthly This set schedule is applicable for once a month period Belkin Components 24 Schedule m sd sd E io p Sio dis sd Noe do so rj Monthly Action The action menu provides you with a list of events to choose from The event and or any combination of these actions can be selected from the Choose Event list box Actions that are already enabled will show a check mark To delay the actions set the desired time for delay in the Delay combo box Belkin Components 25 Set Default Delay 5 el SEOOndis Logging Broadcasting Paging Command SNMP Trap a UN MEM MEM UM UM UM M TI X Receptacle Control a Enable Auto Save Bulldog Plus will save opened files and close applications automatically when you enable this function b Choose Event When you select one item in the list the action buttons will display current settings Press button to do further configurations c Set Default Sets all the actions to default values d Delay The power event must stay within the delay time to trigger actions Action Shutdown Shutdown Hibernate Suspend the operating system or shutdown UPS If you select the shutdown item Bulldog Plus will execute or ignore the Auto Save function
17. a Bulldog Plus icon that lies in the system tray to indicate current UPS status To run the Bulldog Monitor moves the mouse cursor over the Bulldog Plus icon and double click to launch Bulldog Monitor or click the right button to pop up the menu v Show Countdown Monitor Configuration Meters Per Stop EWER 0850 aM Then select Monitor to run the program You can also launch Bulldog Monitor without running Bulldog Service select Bulldog Monitor from Program Files Bulldog Plus menu Belkin Components 9 Bulldog Monitor Main Screen BELKIN BULLDOG Plus Monitor UPS Type On Line UPS Model BU100XR 2000 100 Firmware Version 1 0 Host Name tnsofzem 104 Rating V 10007A Rating Input Volt 1107 Rating Output Volt 1107 Rating Battery Volt 41V Rating Input Freq 60Hz Belkin Components 10 Networking BULLDOG Plus software is comprised of two modules BULLDOG Service and BULLDOG Monitor You may run both the programs in a computer to monitor your localized UPS or run the programs in two different computers Operation Mode BULLDOG Service can operate in Master Mode which allows BULLDOG to send commands to its connected UPS in Serial Slave mode which listens to its connected UPS or in Networking Slave mode which obtains the UPS information from Master via the network If two or more computers are communicating with a single UPS only one of these computers should
18. acement date and countdown time Status UPS status Diagram Indicates the UPS current flow Scroll UPS data graph Outlet Displays outlet status If your UPS cannot control the outlet then this button disappears Network Indicates the connection of Master Slave Bulldog Monitor and Bulldog Service Main UPS Health 3 levels Green yellow and red UPS Type On line off line line interactive or 3 phase on line UPS Model The UPS model which is being monitored by Bulldog Plus Firmware Version Indicating the version status of the UPS internal code Host Name The host which runs Bulldog Plus Rating VA The UPS rating VA Rating Input Voltage The UPS rating input voltage Rating Current The UPS rating current Rating Battery Voltage The UPS rating battery voltage Rating Input Frequency The UPS rating input frequency Test Result Results of the last self test AC Source Normal battery or bypass Battery Status The status of battery Battery Level Percentage of battery level Loading Output loading percentage Bulldog Plus with the ability to change the display item of the meters the Belkin Components 41 referred menu item System Main Screen UPS Tree System System tree for host information and the connection of Master Slave UPS UPS tree for all of the UPS information Time Last Battery Replacement Date To change the date of last battery replacement in the System Configuration UPS UPS Property
19. ation If user runs Bulldog Service and Bulldog Monitor on the same computer you can perform such configurations or control the UPS without the Belkin Components 16 password To change your password please choose the Set Password option from Configure Network menu Monitor Screen This dialog box allows you to change displayed items in the Scroll screen of the Information Display Area Main Screen ish Meters SG Voltagel Output Voltage j Step P Seoond s Scroll Window LO Voltage C VO Frequency Batt Voltage C VO Curent a Language Choose a language that suits your operating system needs Program will automatically replace the on line help file and audio files to your selected preferences Meters Press the Main button from the Bottom Layer Buttons and you will see that there are two meters in the information area You can change the displayed items of the two meters Scroll Window Press the Scroll button from the Bottom Layer Buttons and the scroll window will display the information in this area This item allows you to change the display menu and its items Font This menu allows you to change the font size of Bulldog Monitor window Window This menu allows you to change the display items in the Information Display Area The items in the menu refer to each button in the Bottom Layer Buttons Belkin Components 17 Close Monitor Close Bulldog Monitor and leave Bull
20. be in Master mode the others should be in Slave mode to prevent them from sending contradictory commands Bulldog Plus Master Bulldog Plus Networking Slave Network Line Serial Line Bulldog Plus Serial Slave Ll When a power event occurs the Master gets the information then transmits it to Salve s Each BULLDOG Service executes different Actions FlexEvent so that the system manager can configure different strategies into each different computer For example When a power failure occurs the file server and mail server won t shutdown until the UPS battery is low but other less important workstations execute shutdown after 5 minutes and the initial workstations shutdown after 10 minutes Shutting down workstations preserves more battery power for your mission critical network servers Remote Monitoring and Control Bulldog Monitor has the ability to monitor Local hosts and Remote hosts Belkin Components 11 Bulldog Monitor Bulldog Monitor Bulldog Monitor Bulldog Service Bulldog Service Network Line Local Monitor Remote Monitor You can run only Bulldog Monitor without running Bulldog Service Bulldog Monitor will search hosts in the LAN Local Area Network which runs Bulldog Service in the combo box Click on the Host Selection combo box to list the searched hosts in the LAN Select one then Bulldog Monitor will connect to the selected host BELKIN BULLDOG Plus Monitor System Control View Wizard
21. casting EE EE Ee ee ance 27 Acon Le ale KEE 27 PCHON GOMMAN CG EG OO OR AG 27 Actions ASTE EE esas casas na ray aaa asa 27 Action E AN EE EG RE Ee thet Ee eese tdt itu 27 ACTION SNMP Trap ese AA WA ti nera Re Ede ee ed 27 Action Receptacle Control ee ee Re ee 28 Stop All Acton sesse ES Dette daos datei tos teen deduce 28 s Lee 28 Transter Voltage EE n 28 ADVANCED UPS PROPERTY canaria ed sede raya aano ata ed Ged ees ee ei ese 29 NETWORK creii anaiai EE EE 30 SOL PasSWOIU s ms EE EE EE EE EE EE Ee d 30 Choose Master Slave AEN 30 Wake OM LAIN olt 31 SNMP se GR SG DS AAA mates CU deu 32 SNMP Tiap INU Gi SE ert Ee 33 PETERS at ED DE DE DE De DR DE Re aa 34 el 35 SAULO WANG WA AIKA Ee EM LE LM d ed 35 Ganeel SKUIAOWRE ss LE 35 Turn Receptacle Relay Om 36 Turn Receptacle Relay E E 36 UPS Audible Alarm ON see AA ee ee ee 36 WPS AUGIDIG Alar RE 36 10 Seconds Test 36 Deep Battery Test m 36 Cancel este cc EA M A MA MI E d 36 dl EE ERN 37 WEE 37 Ee 37 alioa AC LEE 38 KUSI NAA DA EG DR NANE 39 Auto Ed EE EE 39 Remote OS c E 40 BOTTOM LAYER BUTTONS Belkin Components VIE ss ER EE AE AD AD EA Pe E EE e m P E 42 Slats EE EE AE EE Aa 42 Eeer 42 SErOI EE rH NEN ENDE rd 42 OUES oii tiU eb ciu NEN ei ub ru eb LIN 42 sio E EN EE 42 SERVICE AND SUPPORLU RE 43 Belkin Components 4 Introduction Congratulations on your purchase of Bulldog Plus to manage your
22. ch runs Bulldog Service If Bulldog Monitor and Bulldog Service runs on the same computer and this field will be empty Belkin Components 20 Devices Notification Users Pager List Program will set the modem to notify all via the pager numbers which are listed in the pager list You can input your pager number for your own notification purposes For example 060123456 is your pager number each tells modem to delay 2 seconds delay time is for setting waiting period for the response signal before proceeding to transmit to the displayed number 119 119 will appear in your pager LCD To trigger the pager notification you must enable the Pager Action in the Action dialog box a Add Add a new pager number b Modify Modify the selected pager number c Delete Delete the selected pager number Notification Users e mail You can also e mail users through SMTP when power events occur To trigger the e mail notification you must enable the e mail Action in the Action dialog box a Add Add a new user b Modify Modify the selected user name c Delete Delete the selected user Notifify Users Network Broadcast You can also broadcast information to users when a power event has occurred The broadcast function is associated with Windows Messenger service To trigger the broadcasting notification you must enable the Broadcast Action in the Action dialog box a Domain Enable this item to broadcast to all the users in the domai
23. depending on your selection in the Action dialog box But if you select the suspend or hibernate item the program will ignore the Auto Save function The action of shutdown hibernate or suspend are the same as if you select the Shutdown Option from the Windows Start menu Action Logging Allows you to log events as well as modify the default logging message You can see this message in the Event Log dialog box Belkin Components 26 Action Broadcasting Permits you to broadcast an event based on a set period of time If you want to be notified once set the time period to 0 However if you want to be notified more than once set the time period to a larger number Each number corresponds to the number of times of notification Action Paging Allows you to set the time period for paging intervals If you want to be notified once set the time period to 0 However if you want to be notified more than once set the time period to a larger number Each number corresponds to the number of times of notification Action Command Permits you to execute command files and set a period of time to delay its activation To test this function you can click the Test button To enable or disable this action mark the Enable Command check box Action Alarm Permits you to send out audible alarm instead of a broadcast message There are two alarms to select from Buzzer and Audio If you choose Audio the Bulld
24. dog Service running Belkin Components 18 Configuration e BELKIN BULLDOG Plus Configure Devices UPS Network BULLDOG Plus Configuration Window UPS Communication Port COM2 Next UPS Test Date Time 12 06 2001 12 00 Next UPS Shutdown Date Time 12 05 2001 20 00 Next UPS Restart Date Time 12 06 2001 08 00 Local Host IP 172 16 176 141 BULLDOG Service Mode Master Remote Host IP The Configuration Screen has a menu bar at the top with three main options Devices This menu allows you to configure the modem pager and e mail applications UPS The UPS menu allows you to plan and set the UPS schedule or perform the Action Network This menu allows you to choose the Master Slave settings or configure SNMP HTTP functions Configuration Window UPS Communication Port COM1 COM4 USB Next UPS Test Date Time The date of the next user initiated UPS self test Setting from System gt Configuration gt UPS gt Schedule Next UPS Shutdown Date Time This field displays the date of the next shutdown the computer and UPS Setting from System gt Configuration gt UPS gt Schedule Next UPS Restart Date Time The date of the next restart UPS Setting from System gt Configuration gt UPS gt Schedule Local Host IP IP address of a computer which runs Bulldog Monitor Belkin Components 19 Bulldog Service Mode Bulldog Service acts as a Master or Slave Remote Host IP The host whi
25. elkin Bulldog displays the countdown time time to shutdown suspend the operating system window to remind the user that the operating system will shutdown or suspend in the displayed time This function lets the user know clearly how much time is left to shutdown suspend the computer when power fails The operating system shutdown time can be adjusted from the Action menu Belkin Components 7 00 04 42 BALE 17 12PM e Monitor Run the Bulldog Plus user interface e Configuration Displays the configuration window allows you to change the UPS parameters e Meters Shows UPS real time meters e Program Stop If this item marked Bulldog Plus stopped Unmark it and the program will resume Once a power event has occurred Bulldog Plus will pop up a broadcast dialog box to inform user what happened to UPS Broadcasting Messages 14 47 32 Power failed The UPS is operating on battery power Belkin Components 8 Bulldog Plus Monitor Bulldog Monitor enables you to control and configure Bulldog Plus through drop down menus and dialog boxes It also allows you to monitor the UPS through the Main Screen lt is not necessary for Bulldog Monitor to reside in your computer s memory the execution depends on the user s requirement This can save precious system resources After finishing the Bulldog Plus installation Bulldog Service automatically loads into memory and runs once the Windows operating system starts up There is
26. emote Hosts Search Result El Host tnsupcfg 172 16 176 62 Model GES501S110 OS Windows 4 Host tnqc 172 16 176 70 Model Unknown OS Windows 98 A Localztnsofzcm 172 16 176 141 Model BU100XP 2000 OS Windoy Host sun sparcl 172 16 176 144 Model GES651V110100 OS SuNOS Host tnsof2kas 172 16 176 146 Model GES6515110 OS Windows 2C Host tnsuplpu 172 16 176 59 Model Unknown OS Windows 98 A Host tnengysf 172 16 176 48 Model Unknown OS Windows 98 Host tnengadd 172 16 176 113 Model GESSO1S OS Windows 98 A yi ar lis a Va Ln Un Ln La Lat wcwuols 179 16 176 152 Madalali OC imi n 99 14 3 9 C Connect To This IP Address ei a Search Result The hosts will be listed in the Search Result list box Select the host you want to connect to and press the Connect button to establish the connection b Connects to this IP address Bulldog Plus will connect to the IP address which you type in c Connect Establish the network connection Belkin Components 40 Bottom Layer Buttons Each button shows the respective information in the Information Area Bs O B 3 u w HS Mein Tree Time Status Diagram Scroll Receptacle Network Main General Information about the UPS Tree There are 2 sub trees in the Bulldog Plus tree System and UPS The system tree is for host information and the status of Master Slave connection the UPS tree is for all other UPS information Time Displays the time for all schedules battery repl
27. munication with the UPS reestablished dupsPowerFail 3 WARNING Power failed The UPS is operating on battery power dupsPowerRestored 4 INFORMATION Power restored The utility power restored dupsLowBattery 5 SEVER The UPS batteries are low and will soon be exhausted dupsReturnFromLowBattery 6 INFORMATION The UPS has returned from a low battery condition dupsLoadWarning 7 INFORMATION Loading percent of the UPS over the Load Warning value dupsNoLongerLoadWarning 8 INFORMATION Returned from Load Warning condition dupsLoadSeverity 9 Warning Loading percent of the UPS over the Load Severity value dupsNoLongerLoadSeverity 10 INFORMATION Returned from Load Severity condition dupsLoadOnBypass 11 WARNING The UPS loads on bypass dupsNoLongerLoadOnBypass 12 INFORMATION The UPS is not on bypass mod dupsUPSFault 13 SEVER A general fault caused in the UPS dupsBatteryGroundFault 14 SEVER The UPS battery ground fault dupsNoLongerBatteryFault 15 INFORMATION The UPS recovered from battery ground fault dupsTestinProgress 16 INFORMATION The UPS test in progress dupsBatteryTestFail 17 SEVER The UPS test in progress dupsFuseFailure 18 SEVER The UPS fuse failed dupsFuseRecovered 19 INFORMATION The UPS fuse recovered dupsOutputOverload 20 SEVER The UPS overload dupsNoLongerOverload 21 INFORMATION Recovered from UPS overload dupsOutputOverCurrent 22 SEVER The UPS output is over current dupsNoLongerOutputOverCurrent 23 INFORMATION Recovered from UPS over curren
28. n otherwise Bulldog Plus will send messages to the hosts that users assign b Add Add a new machine name c Modify Modify the selected machine name d Delete Delete the selected name Color Used to change the screen color Belkin Components 21 a Color Items This area lets you select an item which you want to change the color for The right top corner will display the current selected color b Change Change the color you have selected c Default Default setting d Exit Close the dialog box Close Close the Configuration window Belkin Components 22 UPS UPS Network UPS Property Attached Devices Log Management Schedule Action Stop All Action Voltage Sensitivity Transfer Voltage UPS Property This dialog box allows you to configure the UPS COM port battery replacement date etc Load Warning and Load Severity used to prevent UPS overload see the UPS hardware user manual In general Load Warning will notify the user to reduce the UPS load Load Severity will shutdown the computer to prevent overload a COM Port COM1 COM4 USB b Load Warning Load warning c Load Severity User must reduce UPS load d Last Battery Replacement Date Records the last battery replacement date e Next Battery Replacement Date Displays the date of the next battery replacement Bulldog Plus will notify the user to replace the battery f Host Name Local host name
29. n the Master IP address so that the Slave can connect to the Master host and obtain the UPS information Belkin Components 30 C Serial Slave C Networking Slave Master IP Address Ge Wake On LAN To wake up the remote host Bulldog Plus sends notification through the network You must provide the IP address and the network hardware address of the remote host In Windows98 you can execute the ipconfig All command under the MS DOS prompt to obtain the network cards physical address of the local host Or input the arp a command to see the remote host s physical address Your network card must support the remote wakeup feature and this function should be enabled Wake On LAN Edit Host IP Address Network Card Hardware Address In Hex Wake me up when v SENTRY PULL Plus Resume The Computer From Suspend M Lotti oe er er eer ee to a Bulldog Plus Resume The Computer From Suspend Mode Bulldog Plus will reinstate the computer into normal mode and the program will awaken the remote hosts once the actions have been enabled b Each Time Bulldog Plus Startup Program will wake up the remote hosts which are enabled when Bulldog Plus starts and is connected to the UPS Belkin Components 31 SNMP If you are using a Windows 95 98 Me operating system you can configure the SNMP parameters directly from the Bulldog Plus Select the Accept SNMP packet from any hosts Bulldog Plus will accept all the
30. nd history event or history data o Wizard Directs users to configure the most frequent use of settings the wizard guides users step by step to finish their configuration o Help The Help menu allows you to access the online help system Belkin Components 15 System The system menu allows you to configure the UPS and the monitoring screen parameters When you select the System menu from Main Menu bar a drop down menu appears offering you the following menu options System Control View Login Configuration Monitor Screen Font d Window Close Monitor Login Used for Remote Monitor User must enter the password verification before he can control or configure the UPS Configuration The Configuration menu allows you to tailor various Bulldog Plus parameters Monitor Screen Allows you to change displayed item in the Scroll Screen of Information Display Area Font Sets the font size Bulldog Plus will resize the window automatically Window This menu allows you to change the displayed items in the Information Display Area The items in the menu refer to each button in the Bottom Layer Buttons Close Monitor Stops Bulldog Monitor Login Password When attempting to use Bulldog Monitor as a Remote Monitor connect to different host you have to enter the password for verification if you want to do such tasks as configurations or to control the UPS Otherwise you can only view the UPS inform
31. og Plus requires a wav file to emit the alarm You can browse your system for other wav files by clicking on the Browse button If you want to be notified once set the time period to 0 However if you want to be notified more than once set the time period to a larger number Each number corresponds to the number of times of notification Action e mail Permits you to send e mails through SMTP If you want to be notified once set the time period to 0 However if you want to be notified more than once set the time period to a larger number Each number corresponds to the number of times of notification You can edit the user list by clicking the Edit list button and add modify or delete any user name in the list To enable or disable this action mark the Enable e mail check box Action SNMP Trap Lets you send a SNMP trap when the relative power event occurs To enable or disable this action mark the Enable SNMP Trap check box Belkin Components 27 You also need to specify the SNMP Trap target hosts and community string please see the SNMP dialog box in the Network menu Action Receptacle Control Allows you to control the Receptacle Relay on or off Each Receptacle Relay may control not only one outlet please see the rear panel of your UPS or the UPS hardware user s manual Stop All Action Clicking on this terminates all the actions immediately Voltage Sensitivity Adjusts the UPS voltage sensitivity
32. onitoring 8 Multi computer shutdown restart 9 Support Simple Network Management Protocol SNMP 11 Support HTTP remote monitor and control using Internet browser 12 Support Universal Serial Bus USB 13 Multi lingual menus Belkin Components 5 Bulldog Plus Installation Please note that the USB communication is not supported by Windows 95 and NT 4 0 Bulldog Plus Setup 1 2 3 4 Si 10 Belkin Components 6 Turn off your computer Attach the electrical power cable from the computer to the UPS Attach the electrical power cable from the UPS to an AC power outlet Plug the communication cable into the UPS then plug the other end of the cable into the communication port on your computer Start your computer Check the communication type of your UPS If you select the USB option you must have connected the UPS to the computer and install the HID driver Place the Bulldog CD in your CD ROM device and execute the setup exe to run the setup program During the installation the following dialog gives you 3 options e Program File Files contain Bulldog Service Bulldog Monitor and this on line help e Audio Files Some wav files These files will be played to notify you when power event occurs e SNMP Files Bulldog Plus SNMP DLL file After finishing the installation the setup process will create a Bulldog Plus association The Bulldog Plus software is comprised of two modules e An UPS Monitoring
33. put Freg 50Hz 120 180 pi 1207 180 Recent Event Log BENECA wae L startup the W EI d Diagram Scroll Receptacle Network Host Selection Press the combo box to select hosts that runs Bulldog Plus in the LAN Users can monitor or control the UPS remotely password is needed Connection Indication The logo will rotate while the communication between Bulldog Monitor and Bulldog Service is established Information Display Press Bottom Layer Buttons to change the information that is displayed in this area Recent Event Log Preserve last 10 event logs in the combo box click on the combo box to pull down and view the logs Top Layer Buttons These buttons are used to increase the speed of your operation refer to the dialog boxes in the menu of E E Of Configure Meters EventLog History Configuration Same as the System Configuration in the menu Meters Same as the View Meters in the menu Belkin Components 14 Event Log Same as the View Event Log in the menu History Graph Same as the View gt History Graph in the menu Bulldog Monitor Main Menu The Main Screen has a menu bar at the top with 5 main options e BELKIN BULLDOG Plus Monitor System Control View Wizard Help o System This menu allows you to set the Bulldog Plus and computer parameters o Control This menu allows you to set UPS buzzer outlet and test o View The View menu allows you to see the real time values a
34. t dupsInverterAbnormal 24 SEVER The UPS inverter is operating abnormally dupslnverterRecovered 25 SEVER Recovered from UPS inverter abnormal state dupsRectifierAbnormal 26 SEVER The UPS rectifier is operating abnormally dupsRectifierRecovered 27 INFORMATION The UPS recovered from abnormal state dupsReserveAbnormal 28 SEVER The UPS rectifier is operating abnormally dupsReserveRecovered 29 INFORMATION The UPS rectifier is now operating normally dupsLoadOnReserve 30 INFORMATION The UPS load on reserve dupsNoLongerLoadOnReserve 31 INFORMATION The UPS no longer load on reserve dupsEnvOverTemperature 32 WARNING The environment is over normal temperature DupsNoLongerEnvOverTemperatu 33 INFORMATION The environment recovered from abnormal re temperatures Belkin Components 33 DupsEnvOverHumidity 34 WARNING The environment over normal humidity DupsNoLongerEnvOverHumidity 35 INFORMATION The environment recovered from abnormal humidity HTTP Bulldog Plus supports WEB Server for remote management and to obtain the UPS information Users can use IE or Communicator to connect with Bulldog Service Even your computer doesn t have Bulldog Plus installed you can monitor and control your UPS via the network HTTP E HTTP Root E MriNbcNUPSentry SmartWiWWwmeoot Port Number Eo E a Enable HTTP Enable or disable the feature of Web service b HTTP Root The HTTP root path All the html and gif files will be