Home

BEA BODYGUARD III GT 400 User's Manual

image

Contents

1. BODYGUARD III OPEN UP NE ONS QUICK SETUP GUIDE A HALMA COMPANY PRESENCE SENSOR FOR PEDESTRIAN DOORS 1 Description The Bodyguard III Quick Setup Guide is for the installation and setup of the Bodyguard III This document is provided for experienced installers service personnel amp AAADM Certified Inspectors that are familiar with the Bodyguard III For those who are not completely familiar with the installation and setup of the Bodyguard III BEA recommends following the detailed installation and setup instructions found in the Bodyguard III User s Guide 75 5134 Bodyguard performance shall be adjusted and in compliance with all applicable current safety standards ANSI A156 10 2 Installation 1 The Bodyguard shall be mounted near flush with the bottom of the automatic door header on the swing side This is absolutely necessary to allow the Bodyguard detection pattern to reach back through the threshold area when the door is in the open position If any portion of the door face or related hardware on the swing side project beyond the Bodyguard face a Bodymount must be installed in conjunction with the Bodyguard 2 The Bodyguard should be mounted at a height range of 6 6 to 8 Max of 9 3 The Bodyguard should be center mounted up above on the header and flush with the bottom of the automatic door header This is absolutely necessary to allow the detection pattern to reach back through the threshold area with
2. ume woe res 9 Company Contact Company Contact Do not leave problems unresolved If a satisfactory solution cannot be achieved after troubleshooting a problem please call BEA Inc If you must wait for the A following workday to call BEA leave the door inoperable until satisfactory repairs can be made Never sacrifice the safe operation of the automatic door or OPEN UP NE NS gate for an incomplete solution The following numbers can be called 24 hours a day 7 days a week For more information visit www beasensors com A HALMA COMPANY US and Canada 1 866 249 7937 Southeast 1 800 407 4545 Canada 1 866 836 1863 Midwest 1 888 308 8843 Northeast 1 866 836 1863 West 1 888 419 2564 Page 2 of 2 75 5362 01 20090210
3. e attaching it to the 6 jData Brown NOTE pe short the al eee Bodyguard ec 4 Mechanical Adjustment 1 Aside from placement on the header the only mechanical adjustment that may be made to the sensor is the angle adjustment The Bodyguard is factory pre set to the 5 position but may be reduced to a 0 position or increased to a 10 position The greater the angle the farther from the door the pattern will be The 0 angle should only be used when the Bodyguard is mounted to a Bodymount block or to a soffit above the door that extends out from the face of the swing side of the door in this case the 0 setting would improve the location of the detection field across the threshold area of the doorway It is recommended that for most applications the unit be powered and walk tested at the pre set 5 angle After walk testing if the detection field needs to be changed then proceed with changes as explained next 2 To change the angle setting the end caps lenses center eye shield and terminal block if it has been wired must be removed Once removed release the white clips and rotate outward to remove the PCB Once the PCB is completely removed from the housing the angle position may be changed There are two clips per Bodyguard and the angle must ANGLE ADJUSTMENT match for each clip on the PCB CLIP WHITE 5 Setup 1 Upon completion of mechanical and electrical installation apply 12 to 24 VAC VDC 10 to the Bodyguard w
4. ith the door in the closed position The Bodyguard will flash a green LED at a rate of 2 Hz then it will expire upon a successful set up in the door closed position NOTE If applying the Bodyguard to a door control that requires a learn cycle upon powering it is recommended to allow the doors to complete a learn cycle before applying power to the Bodyguard 2 Activate the door to the full open position When using BEA s lockout relay the Bodyguard will once again flash the green LED and will execute a door open set up Upon completion of the set up for the door open position the doors will begin closing Normal operation should resume thereafter Proceed with fine tuning to insure compliance with all current applicable safety standards i e ANSI A 156 10 If set up is unsuccessful refer to the Troubleshooting Guide at the end of the Bodyguard User s Guide 75 5134 and also to the guide located at the end of the respective lockout User s Guide HELPFUL HINT After set up and to confirm the correct motor polarity to the lockout the correct data and data polarity and to ensure the lockout is communicating properly to the Bodyguard Activate the door open and perform a door open set up with the remote by pressing Unlock Magic Wand 2 If the Bodyguard flashes green continue with final tune in If not refer to Bodyguard User Guide 75 5134 The most likely cause is the motor lead polarity is reversed at the lockout or data polarity is rever
5. sed at Bodyguard 75 5362 01 20090210 Page 1 of 2 Pattern Width Depth amp Sensitivity all have independent door closed and 6 Sensing Zone Adjustment door open values Patte Ta De oth Pattern Width Open Closed 1 Deep Threshold ON 2 Medium Threshold ON OPEN 1 Wide CLOSED DOOR 4 Asymmetric Right Narrow 7 Asymmetric Left Wide 3 Limited Threshold ON 2 Middle OPEN DOOR 5 Narrow Left 8 Asymmetric Right Wide 4 Deep Threshold OFF 3 Asymmetric Left Narrow 6 Narrow Right 9 Center Narrow 5 Medium Threshold OFF CLOSED 6 Limited Threshold OFF meet ANT LYNS LAN 33 SS _ Le PRET ILL wa Emy LAZ NE LAG OTAS LER LL A S PANG Ta ZN SERR oy AAN NOTE When pattern width or depth is E r a setup of the new aie size will automatically be triggered once a value key has been pressed O 7 Configurations Co nfi g u rati ons ENSURE COMPLIANCE WITH ALL APPLICABLE CURRENT SAFETY STANDARDS I E ANSI A156 10 SENSITIVITY INTERFACE Door Closed 6 i New Style Door Open 7 Old Style LO21 B K P S U LO LINX MC15 AUTO LEARN LEARN SETUP WAND 30 sec Door Closed 1 Infinite Door Open 2 Restore to Default HOLD TIME FREQUENCY Normal Mode Low Normal Mode High Quiet Mode Low Quiet Mode High icles Door Control Connections a lt a creer we res vetow one Caw oo ove rome oo Coge vetow res ove varn me reo
6. the Bodyguard is in the open door position SINGLE DOOR APPLICATIONS The Bodyguard should be mounted overhead at the center of the door opening However if this is not possible the unit may be installed off center In such cases pattern location will have to be altered for proper placement of the field of detection Try to avoid mounting locations that may pose potential problems such as directly over a door arm DOUBLE EGRESS APPLICATIONS One Bodyguard shall be mounted overhead on the header over each swing path There should be at least 40 of separation between the 2 Bodyguards when measured between the centerline of each sensor Most double egress applications are knowing act Ensure compliance with current ANSI 156 10 2005 Section 9 2 Most double egress installations will require IR frequency and or open door pattern depth adjustments Change IR frequency of one Bodyguard to 3 and the other to 4 See Tech Bulletin 32 or Bodyguard User Guide 75 5134 for more explicit information regarding double egress applications with respect to location and setting up the Bodyguard 3 Wiring WIRE COLOR Red Use the cable that is provided for use with the 12 to 24 VACIVDC 10 10 pin connector as shown or wire the 7 pin terminal block If wiring the Bodyguard to a BEA module i e LO LINX or a version of the LO 21 refer to the wiring diagrams for the 5 ING respective module For ease of installation O NE ers wire the terminal befor