1. slider hose shelf sleeve thermostat cartridge thermoelement panel thermoelement panel Il side cover valve cover panel valve cover panel Il escutcheon handshower Solaris Stratos Metro Interaktiv S handle Interaktiv S handle Solaris handle Stratos handle M etro check valve tub spout panel Il only hardware kit hose connection elbow 97024000 28276XXX 25969000 88520XXX 94282000 88533000 88500000 25974880 25976880 25985880 25981XXX 28518XX1 28507XX1 28502XX1 88549XXX 88530XXX 88547XXX 88548XXX 94074000 88584XXX 25977000 25978000 XXX finish 000 chrome 820 brushed nickel Cleaning Recommendation for Hansgrohe Products Modern sanitary faucetry and shower fixtures consist of very different materials to comply with the needs of the market with regard to design and functionality To avoid damage and returns itis necessary to consider certain points when cleaning Cleaning materials for faucets and shower products Acids are necessary ingredients of cleaning materials for removing lime However please pay attention to the following points when cleaning faucets and shower products Use only cleaning materials intended for the application Never use cleaning materials which contain hydrochloric formic or phosphoric or acetic acid as these can cause considerable damage e Do not mix one cleaning material with an
2. Interaktiv Showerpanel ansgrohe Interaktiv Showerpanel Interaktiv Showerpanel Il 54 3 4 54 3 4 21 2 Na 1 2 max 16 1 2 Show erpanel I Show erpanel Il handshower amp bodyjets handshower bodyjets tub spout Metro 06572000 06573000 Solaris 06549XX0 06550XX0 Stratos 06564XX0 06565XX0 Interaktiv S 06893000 06894000 Proaktiv 06964000 06971000 Product Specification Flow rate of handshower 2 5 gpm Flow rate of each bodyjet 1 0 gpm Maximum flow rate of thermostatic mixing valve 8 gpm 45 psi 10 gpm 65 psi Recommended incoming hot water temperature 120 140 F Recommended incoming water pressure 45 72 psi Anodized aluminum body Listed by Underwriters Laboratories Backflow protection provided by check valve in handshower outlet The high temperature limit stop on the thermostatic mixing valve cartridge can be re set to comply with local plumbing codes see page 13 Proaktiv showerpanels are sold without trim Proaktiv showerpanel trim kits are sold separately Please know and follow all applicable local plumbing codes when setting the temperature on the water heater In Massachusetts the water heater may be set no higher than 112 F 2 Check Package Contents Save time and aggravation Before beginning installation check the contents of this package Make sure that all parts are present and in good co
3. THIS WARRANTY IS THE EXCLUSIVE REM EDY OF THE PURCHASER HAN SGROHE NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO CREATE FOR IT ANY OBLIGATION OR LIA BILITY IN CONNECTION WITH THIS PRO DUCT HAN SG RO HE SHALLN OT BE LIABLE TO PURCHASER OR ANY PERSON FORANY INCIDEN TAL SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY IN CLUDING MERCHAN TABILITY Some States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from State to State You may be required by law to give us a reasonable opportunity to correct or cure any failure to comply before you can bring any action in court against us under the Magnuson M oss Warranty Act PRODUCT INSTRUCTIONS AND QUESTIONS Upon purchase or prior to installation please carefully inspect your Hansgrohe product for any damage or visible defect Prior to installing always carefully study the enclosed instructions on the proper installation and the care and maintenance of the product If you have questions at any time about the use installation or performance of your Hansgrohe product or this warranty please call or write to us at the toll free number and address printed above 19 ansgrone Hansgrohe Inc e 1490 Bluegrass Lakes Parkway e Alpharetta GA 30004 Tel 770 360 9880 e Fax
4. 770 360 9887 ww w hansgrohe USA com US Installation Instructions e Part No 90972801 03 e Revised 12 2006
5. Canada WHO IS COVERED BY THE WARRANTY This warranty extends to the original consumer purchaser only WHAT IS COVERED BY THE WARRANTY This warranty covers only your Hansgrohe manufactured product Hansgrohe warrants this product against defects in material or workmanship as follows Hansgrohe will repair atno charge for parts only or atits option replace any product or part of the product which proves defective because of improper workmanship and or material under normal installation use service and maintenance If Hansgrohe is unable to provide a replacement and repair is not practical or cannot be timely made Hansgrohe may elect to refund the purchase price in exchange for the return of the product LENGTH OF WARRANTY Replacement or repaired parts of products will be covered for the term of this warranty as stated in the following two sentences If you are a consumer who purchased the product for use primarily for personal family or household purposes this warranty extends for as long as you own the product and the home in which the product is installed If you purchased the product for use primarily for any other purpose including without limitation a commercial purpose this warranty extends only i for 1 18 year with respect to Interaktiv and Retroaktiv products and ii for 5 years with respect to AXO R ShowerPower and Pharo products THIS WARRANTY DOES NOT COVER AND HANSGROHE WILL NOT PAY FOR A Conditions malfunctio
6. face and make the wall watertight before installing the panel The panel hangs on the finished wall Seal the wall around the nipples with waterproof sealant Installation on a Flat Wall Installation in 90 Corner i 1 m i n i m i 1 2 hot amp cold supply li i i ot amp cold supply lines 172 nipple ae A can be right or left gt 6 7 m of corner 2 i hot water N i n e i o i i un i oO i _ i j IL cold water is at D il i N 2 lt t i x ee i am i i Ve x OD oA gE i 92 io lt t i E standing surface Y Installation Flat Wall W rap the threads on the supply nipples with Teflon thread tape Install the enclosed elbows so that the outlets face upwards Measure up the wall 78 34 making sure that the line is plumb Mark the position for the top screw hole From the position of the top screw hole measure down 35 3 8 Mark the position for the center screw hole From the center screw hole measure down 19 1 8 Mark the position for the bottom screw hole Use a 6 mm drill bit suitable for the wall surface Drill the three screw holes Install the anchors Seal the wall around the anchors with waterproof sealant Install the set screws in the top and bottom holes Use a 10 mm nut driver to attach a nut to the top set screw Slide the panel over the top and bottom set screws Tighten the nut on the top set screw Install and tighte
7. hors with waterproof sealant Install the mounting brackets to the walls using five of the recessed head screws Install the corner sealing gasket to the grooves on the panel W hile a helper holds the panel attach the supply hoses to the elbows with the compression fittings Use two wrenches as shown in the diagram to prevent the supply hoses from twisting Tighten the hex head cap screw on the top mounting bracket Install and tighten the hex head cap screw on the bottom mounting bracket through the hole in the panel and tighten Install the hex head cap screw and large washer on the center mounting bracket through the hole in the panel and tighten Clip the side cover seals as shown in the diagram Attach the side cover seals to the valve cover Push the bodyjet supply hose on the valve cover into the fitting on the panel Install the valve cover on the panel The pins on the cover must connectto the slots on the panel Turn to page 11 to continue the installation 10 Install the Handle Push the handle over the valve stem Tighten the set screw on the bottom of the handle with a 3 mm Allen wrench The set screw must engage the slot milled into the thermoelement Install the Handshow er Place a black rubber washer in the short hose end connector Screw the short hose end connector to the handshower outleton the panel Place the screen
8. n the nut on the bottom set screw Install one recessed head screw and the large washer on the center hole Tighten the screw I n EI L mm 5 Use the compression nuts and ferrules to connect the supply hoses on the panel to the supply elbows Use two wrenches as shown to prevent the supply hoses from twisting Attach the seals to the side covers Install the side covers The pins on the covers must go into the grooves on the sides of the panel Push the bodyjet supply hose on the valve cover into the fitting on the panel Install the valve cover on the panel The pins on the cover must connect to the slots on the panel Turn to page 11 to continue the installation Installation in 90 Corner W rap the threads on the nipples with Teflon thread tape Install the enclosed elbows so thatthe outlets face upwards In the corner measure up the wall 78 3 4 making sure that the line is plumb Mark the position for the top mounting bracket From the position of the top screw hole measure down 35 3 8 Mark the position for the center mounting bracket From the center screw hole measure down 19 1 8 Mark the position for the bottom mounting bracket Use the mounting brackets as templates to mark the positions of the screw holes Drill the holes with a 6 mm bit suitable for the wall surface Installthe anchors Seal around the anc
9. ndition If any partis missing or damaged please contact Hansgrohe Customer Service before proceeding handshower side covers 2 _ side cover seals 2 _ u 1 2 x 10 mm elbows with compression fittings corner mounting brackets 3 recessed screws amp anchors 6 Tools Required corner mount seal K 63 Techniflex hose hex head cap screws with nuts 3 set screws 2 small washers 6 large washer Note the handshower and Techniflex hose are not included with the Proaktiv showerpanel They are included with the trim kit sold sepa rately The following tools are suggested for installing the Interaktiv Showerpanel Tape measure Level Grease pencil or other marking device Drill with 6 mm bit suitable for wall surface 10 mm nut driver 10 11 and 19 mm wrenches 3 mm Allen wrench Philips screw driver W aterproof sealant M allet to install anchors Teflon thread tape Roughing in This unit can be installed on a flat wall or in a 90 corner Instructions for installation on a flatwall begin on page 5 Go to page 8 if the panel is to be installed in a corner Ensure that you have a minimum 83 ceiling height from the standing surface Stub out 1 2 N PT male nipples for the hot and cold water supplies at the locations shown on the appropriate rough in diagram The nipples should extend 5 8 outside the surface of the finished wall Install the wall sur
10. ning system If scale deposits are noticed in the spray channels turn the water on lightly and rub the spray channels with a finger or a sponge If scale deposits are noticed on the spray face pour about 3 4 of a commercial scale remover such as Lime Away or CLR into a shallow dish Dilute the remover according to the label instructions vr Soak only the spray face in the solution for the amount of time specified on the label Rinse the handshower with clear water Reinstall the handshower Turn on the water and allow the handshower to flush for at least one minute Check Valve Maintenance The check valve should be removed and inspected yearly If the check valve is damaged it should be replaced check valve Clean the Thermostatic Cartridge Filters A possible cause of lost pressure especially if the pressure decreases as the temperature increases is debris clogging the filter screens on the thermostatic cartridge If this occurs the screens should be cleaned Turn the water off atthe main Remove the handle Hold the thermoelement steady with a 36 mm wrench Use a 24 mm wrench to unscrew the ther mostat cartridge from the thermoelement Clean the filter screens under running water An old toothbrush may be used if care is taken not to dam age the filter screens Reinstall the thermostat cartridge 16 Replacement Parts oVPwem Hp Woon e O
11. ns or damage not resulting from defects in material or workmanship B Conditions malfunctions or damage resulting from 1 improper installation improper maintenance misuse abuse negligence accident or alteration or 2 the use of abrasive or caustic cleaning agents or no rinse cleaning products or the use of the product in any manner contrary to the product instructions C Labor or other expenses for the disconnection or return of the product for warranty service or for installation or reinstallation of the product D Accessories or related products not manufactured by Hansgrohe TO OBTAIN WARRANTY SERVICE Contact your Hansgrohe retailer or write to Technical Service at Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta GA 30004 Or call Hansgrohe toll free at 800 334 0455 In requesting warranty service you will need to provide 1 The sales receipt or other evidence of the date and place of purchase 2 A description of the problem 3 Delivery of the product or the defective part postage prepaid and carefully packed and insured to Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta Georgia 30004 Attention Technical Service if required by Hansgrohe W hen warranty service is completed any repaired or replacement product or part will be returned to you postage prepaid EXCLUSIONS AND LIMITATIONS REPAIR OR REPLACEMENT OR IN LIMITED CIRCUMSTANCES REFUN D OF THE PURCHASE PRICE AS PRO VIDED UN DER
12. other Do not use abrasives such as cleaning powders sponge pads or microfiber cloths Cleaning Instructions for Faucets and Shower Products Please follow the cleaning material manufacturer s instructions In addition please note the following Clean your faucets and shower products as and when required Follow the label instructions Do not allow any cleaner to remain on the product for longer than necessary Regular cleaning will prevent scale buildup and water spotting W hen using spray cleaners spray first onto a sponge or cloth Do not spray directly onto the faucet or shower product as drops could enter openings or gaps and cause damage e After cleaning rinse thoroughly with clear water to remove any cleaner residue Important Residues of liquid soaps shampoos and shower foams can also cause damage so rinse with clean water after using Please note e If the surface is already damaged the effect of cleaning materials will cause further damage Components with damaged surfaces must be replaced otherwise this could cause injury Damage caused by improper treatment will not be covered by our warranty Limited Lifetime Consumer Warranty This product has been manufactured and tested to the highest quality standards by Hansgrohe Inc Hansgrohe This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1 1996 and installed in either the United States or
13. the top of the cartridge Replace the clip User Instructions Showerpanel I Turn the temperature control knob clockwise to make the water cooler counter clockwise to make it warmer The knob will stop atthe 100 F position If water hotter than 100 F is desired push in on the knob and continue turning it counter clockwise From the off position turn the diverter handle counter clockwise for the handshower Turn the diverter handle clockwise for the bodysprays Turn the handle further clockwise for the handshower and the bodysprays simultaneously F o User Instructions Showerpanel Il off position temperature control knob diverter handle Turn the temperature control knob clockwise to make the water cooler counter clockwise to make it warmer The knob will stop atthe 100 F position If water hotter than 100 F is desired push in on the knob and continue turning it counter clockwise From the off position turn the diverter handle counter clockwise for the tub spout Turn the diverter handle clockwise for the handshower then for the handshower and bodysprays simultaneously and finally for the bodysprays Using the Handshower The handshower has 3 spray modes Rainl AIR W hirl AIR and Balance AIR Push the function lever until the desired function lever spray mode is achieved 14 Scale Removal The Raindance Air 3 jet handshower incorporates the Rubit clea
14. washer in the long hose end connector Screw the long hose end connector to the handshower Place the handshower in the handshower holder Adjust the Slider Use a 2 5 mm Allen wrench to adjust the tension on the slider Turn the screw clockwise to make the slider easier to move Turn the screw counter clockwise to make the slider harder to move Justify the Handle Turn the water on to the Turn the temperature control Remove the handle handshower knob so thatthe water mea sures 100 F on a thermom eter Turn the water off Turn the temperature control Replace the handle Tighten knob so that the indicator is the set screw next to the 100 marking 12 Set the High Temperature Limit Stop optional Loosen the set screw on the Remove the handle Remove the clip and the high handle temperature limit stop from the stem Grasp the barrel on the Turn the stem until the water coming out of the handshower cartridge and turn it counter is the desired maximum high temperature usually about clockwise to turn on the 110 F handshower Grasp the barrel and turn it Replace the high temperature Reinstall the handle Tighten clockwise to turn the water imit stop so thatitisagainst the set screw off the brass stop on

Download Pdf Manuals

image

Related Search

Related Contents

  HDfury 3D Glasses and Emitter User Manual Rev 1.0  Electric height adjustable frame Marco electrico  Registration Manual - Financial Services Knowledge Portal  American Power Conversion BK500IACH User's Manual  Avis Technique 14/08-1312  Electro-Voice N/D857 User's Manual  RFID Logger Software User Manual  Kicker ZR1000 Car Audio Amplifier  080 34 00 Rev2 Folheto de Instrucoes Ventilador Protect  