Home
Avaya Serial Adapter Module Supplement User's Manual
Contents
1. Serial Adapter Module Supplement Part No 303124 A Rev 01 November 1998 S Bay Networks where information Flows 303124 A Rev O1 n Bay Networks Where Information Flows 4401 Great America Parkway 8 Federal Street Santa Clara CA 95054 Billerica MA 01821 Copyright 1998 Bay Networks Inc All rights reserved Printed in the USA November 1998 The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Bay Networks Inc Trademarks AN Optivity Quick2Config and Bay Networks are registered trademarks and Advanced Remote Node ANH ARN BayRS BayStack BCC and the Bay Networks logo are trademarks of Bay Networks Inc All other trademarks and registered trademarks are the property of their respective owners Statement of Conditions In the interest of improving internal design operational function and or reliability Bay Networks Inc reserves the right to make changes to the products described in this document without notice Bay Networks Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein
2. Canada label identifies certified equipment This certification means that the equipment meets telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent the degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate 303124 A Rev 01 iii Notice For equipme
3. Part 68 of FCC Rules All direct connections to telephone network lines must be made using standard plugs and jacks compliant with FCC Part 68 Please note the following 1 You are required to request service from the telephone company before you connect the unit to a network When you request service you must provide the telephone company with the following data When you request T1 Service you must provide the telephone company with The Facility Interface Code Provide the telephone company with all the codes below 04DU9 BN 1 544 MB D4 framing format 04DU9 DN 1 544 MB D4 framing format with B8ZF coding 04DU9 1KN 1 544 MB ESF framing format 04DU9 ISN 1 544 MB ESF framing format with B8ZF coding 04DU9 1ZN 1 544 MB ANSI ESF and ZBTSI without line power The telephone company will select the code it has available The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJA8C 303124 A Rev 01 When you request 56K 64K Service you must provide the telephone company with The Facility Interface Code 04DU5 56 64 The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJ48S When you request V 34 Service you must provide the telephone company with The required Universal Service Order Code USOC jack RJ11C The make model number Ringer Equivalence Number REN and FCC Registration number of the unit The
4. REN helps you determine the number of devices you can connect to your telephone line and still have all of those devices ring when your number is called In most but not all areas the sum of the RENS of all devices should not exceed 5 0 To be certain of the number of devices you can connect to your line you should call your local telephone company to determine the maximum REN for your calling area This equipment must not be used on party lines or coin lines When you request ISDN U Interface Service you must provide the telephone company with The Facility Interface Code 02185 The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJ49C When you request ISDN S T Interface Service you must provide the telephone company with The Service Order Code s SOC 6 0N The make model number and FCC Registration number of the NT1 Note ISDN S T cannot be directly connected to the network When you request Primary Rate ISDN Service you must provide the telephone company with The Facility Interface Code 04DU9 1SN 1 544 MB ESF framing format with B8ZF coding The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJA8C 2 Your telephone company may make changes to its facilities equipment operations or procedures that could affect the proper functioning of your equipment The telephone company will notify you in advance of such
5. changes to give you an opportunity to maintain uninterrupted telephone service 3 If the unit causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance but if advance notice is not practical you will be notified as soon as possible and will be informed of your right to file a complaint with the FCC 4 If you experience trouble with the unit please contact the Bay Networks Technical Solutions Center in your area for service or repairs Repairs should be performed only by service personnel authorized by Bay Networks Inc United States 1 800 2LAN WAN Valbonne France 33 4 92 96 69 68 Sydney Australia 61 2 9927 8800 Tokyo Japan 81 3 5402 0180 5 You are required to notify the telephone company when you disconnect the unit from the network 303124 A Rev 01 V Using the Serial Adapter Module This document supplements one of the following guides Installing an Adapter Module in a BayStack AN or ANH Router Installing and Operating BayStack ARN Routers Chapter 4 Installing a WAN Adapter Module Follow the hardware installation steps in the guide for your router referring to this document for information specific to the ARN Serial and ANS ANH Third Synchronous adapter module Information in this supplement includes Verifying Router Requirements on page 1 e Attaching Cables on page 2 e Completing Software Config
6. USA Requirements Only Federal Communications Commission FCC Compliance Notice Radio Frequency Notice Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense European Requirements Only EN 55 022 Statement This is to certify that the Bay Networks product or system name is shielded against the generation of radio interference in accordance with the application of Council Directive 89 336 EEC Article 4a Conformity is declared by the application of EN 55 022 Class A CISPR 22 Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures EC Declaration of Conformity This product conforms or these products conform to the provisions of Council Directive 89 336 EEC and 73 23 EEC Th
7. e Declaration of Conformity is available on the Bay Networks World Wide Web site at www baynetworks com ii 303124 A Rev 01 Japan Nippon Requirements Only Voluntary Control Council for Interference VCCI Statement CO Xi FHUBRESERRERER BRS VCCI OE ICAEO 7 2A A Tiii EIE CT CO Xi KERK CHAT 5 LE R fS amp EEIICAAO0sxd O08 8i dH 384 0 EST SBLIBRENSECEMBVET Voluntary Control Council for Interference VCCI Statement This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions Canada Requirements Only Canadian Department of Communications Radio Interference Regulations This digital apparatus product or system name gt does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique product or system name gt respecte les limites de bruits radio lectriques visant les appareils num riques de classe A prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada Canada CS 03 Rules and Regulations Notice The Industry
8. he following Serial adapter module and enable default Configuring and Managing Routers with software services Site Manager Using the Bay Command Console e Configuring Your Router Using the Quick2Config Tool Configure line services Configuring WAN Line Services Configure WAN protocol services Any of the BayRS WAN or System Suite guides including e Configuring IP Services e Configuring Frame Relay Services e Configuring X 25 Services Configuring PPP Services For the latest information be sure to review the Release Notes and Documentation Changes for your version of BayRS software Interpreting LEDs The Serial adapter module RLSD Received Line Signal Detection LED lights when the serial interface detects data transfer The LED will blink on and off during diagnostic testing but does not indicate data transfer until you have configured and enabled the software services 4 303124 A Rev 01
9. nt using loopstart lines please note that the Ringer Equivalence Number REN assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5 The REN is located on the FCC Rules Part 68 label located on the bracket of the module or on the back of the unit Canada CS 03 Regles et reglements Avis L tiquette d Industrie Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme aux normes de protection d exploitation et de s curit des r seaux de t l communications comme le prescrivent les documents concernant les exigences techniques relatives au mat riel terminal Le Minist re n assure toutefois pas que le mat riel fonctionnera la satisfaction de l utilisateur Avant d installer ce mat riel l utilisateur doit s assurer qu il est permis de le raccorder aux installations de l entreprise locale de t l communication Le mat riel doit galement tre install en suivant une m thode accept e de raccordement L abonn ne doit pas oublier qu il est possible que la conformit aux conditions nonc es ci dessus n emp che pas la d gradation du service dans certaines situations Les r parations de mat riel homologu doiven
10. oe interface ARN0066A Figure 1 ARN Serial Adapter Module Connector Slot 2 2 303124 A Rev 01 Using the Serial Adapter Module We IHI 5 4 h S ss LL Je Q xcvH UP ox COM2 COM 1 N nade Emme Lj 8 sr CG e soso CL e 0 0 RLSD2 RLSD1 Third synchronous interface ANHO133A Figure 2 Serial Adapter Module Connector on an AN or 12 Port ANH LJ w el bi uS c X COM2 COM 1 S D mu S COM 3 Expansion amp S Third synchronous interface ANHI37A Figure 3 Serial Adapter Module Connector on an 8 Port ANH 303124 A Rev 01 3 Serial Adapter Module Supplement Completing Software Configuration Once you have successfully installed the Serial adapter module complete the following software configuration tasks using instructions found in your BayRS documentation Configuration Task Location of Instructions Connect the ARN to the network One of the following Installing and Operating BayStack AN and ANH Routers Installing and Operating BayStack ARN Routers e Configuring BayStack Remote Access Modify the ARN configuration file to add the Any of t
11. t tre coordonn es par un repr sentant d sign par le fournisseur L entreprise de t l communications peut demander l utilisateur de d brancher un appareil la suite de r parations ou de modifications effectu es par l utilisateur ou cause de mauvais fonctionnement Pour sa propre protection l utilisateur doit s assurer que tous les fils de mise la terre de la source d nergie lectrique des lignes t l phoniques et des canalisations d eau m talliques s il y en a sont raccord s ensemble Cette pr caution est particuli rement importante dans les r gions rurales Avertissement L utilisateur ne doit pas tenter de faire ces raccordements lui m me il doit avoir recours un service d inspection des installations lectriques ou un lectricien selon le cas Avis Veuillez prendre note que pour tout appareillage supportant des lignes de type loopstart l indice d quivalence de la sonnerie IES assign chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent tre raccord s une interface La terminaison d une interface t l phonique peut consister en une combinaison de quelques dispositifs la seule condition que la somme d indices d quivalence de la sonnerie de tous les dispositifs n exc de pas 5 Le REN figure sur l tiquette FCC Rules Part 68 situ e sur le support du module ou l arri re de l unit FCC Part 68 Compliance Statement This equipment complies with
12. uration on page 4 N Interpreting LEDs on page 4 Verifying Router Requirements Table 1 shows the minimum versions of boot and diagnostic programmable read only memory PROM code required for a serial adapter module Table 1 PROM Diagnostic and Boot Code for Serial Adapter Module Router Type Code Type Minimum Version Directory File Name ARN Boot 1 17 arn proms arnboot exe Diagnostic 1 30 arn proms arndiag exe AN ANH Boot 8 12 an proms anboot exe Diagnostic 5 31 an proms andiag exe For information on upgrading PROM see the BayRS Upgrading Routers guide 303124 A Rev 01 Serial Adapter Module Supplement Attaching Cables Connect the communications cable to the 44 pin DSUB connector on the installed adapter module You install the Serial adapter module in an open adapter module slot on the router as follows e ARN one of the two front panel WAN adapter module slots Figure 1 See Installing and Operating BayStack ARN Routers e AN or 12 port ANH the back panel adapter module slot Figure 2 See Installing an Adapter Module in a BayStack AN or ANH Router e 8 port ANH the back panel COM3 slot Figure 3 See Installing an Adapter Module in a BayStack AN or ANH Router ARN front panel U O T 10Basel D ISDNBRI o wihNTi O EJ G k He D e020 1 SRE 0 z BaseT