Home

Avaya Configuring BayStack and Business Policy Switches with the Optivity Network Configuration System User's Manual

image

Contents

1. or MDA to select switch ports In the Properties tab choose the Basic VLAN STP or IGMP configuration tab NOTE Selecting multiple ports Ctrl Click or Shift Click and then modifying parameters from the Properties tab changes those parameters for all selected ports By default all unconfigured ports are untagged links in the default port based VLAN VLAN 1 participate in normal learning STP and autonegotiate line speed Property Value Operational Status Administration Status Enabled v Autonegotiate v Port speed Configure an MLT You can configure from one through six multilink trunk MLT groups Configure VLANs 1 In the navigation pane expand the device and select the device VLANs folder You can configure port based protocol based or MAC source address VLANs NOTE Use the device VLANs folder to create VLANs and to configure VLAN ports The system VLANs folder shows the VLANs configured on all devices in the database q In the navigation pane expand the switch and select two three or four Ethernet ports i 2 Create shortcuts from the ports to one of the six MLT Basic templates Property Value 3 Copy the ports and then paste them as shortcuts on the sm Lild A MLT Property ID Status MLT Disabled v 4 Inthe navigation pane select the MLT In the Properties tab type a descriptive name to identify the trunk 6 From the Status list choose Enable
2. If you are familiar with the BayStack Console Interface Cl use the following table to locate the Optivity NCS properties that you want to configure Mapping Switch Console Interface commands to Optivity NCS GUI properties To configure the properties on this Cl Screen Select this item in the Optivity NCS navigation pane and choose this Properties tab IP Configuration Setup SNMP Configuration System Characteristics Switch Configuration gt VLAN Configuration menu gt VLAN Configuration Switch Configuration gt VLAN Configuration menu gt VLAN Port Configuration Switch Configuration gt VLAN Configuration menu gt VLAN Display by Port Switch Configuration gt Port Configuration Switch Configuration gt Multilink Trunk Configuration Switch Configuration gt IGMP Configuration Switch Configuration gt IGMP gt port Switch Configuration gt ATM Configuration Spanning Tree Configuration Spanning Tree Configuration gt port Software Download Switch Switch gt SNMP Switch Switch gt VLANs folder gt VLAN Switch gt port member of VLAN VLANs folder gt VLAN Switch gt port Switch gt MLT groups gt MLT VLAN gt IGMP tab and IGMP tab on ports Switch gt port Switch gt ATM MDA port Switch gt STG Group gt Spanning Tree group Switch gt port Switch Basic Basic Import Export Basic VLAN Basic Basic Basic Basic IGMP Ba
3. MLT Configure a Simple Network Management Protocol SNMP trap receiver Each of these tasks is explained in more detail in the procedures that follow Configure the switch IP address Connect a serial console and apply power to the switch After the Nortel Networks logo screen appears press Ctrl Y to access the Console Interface Cl 2 Atthe Cl Main Menu choose IP Configuration Setup 3 Type the in band IP address or stack IP address subnet mask and default gateway of the switch Press Return after each entry NOTE If you have a properly configured BootP server in your network it detects the switch IP address automatically you do not need to configure the IP address For a standalone switch you enter the in band IP address For a stack configuration you enter the stack IP address Import or create a switch configuration 1 Use the Configuration menu Import commands to import configuration data directly from a switch To import data you specify the switch IP address and community string 2 Use the Configuration Data Palette to create new standalone switch and stack configurations The Palette lists switch templates by product group You can import existing configurations to the Optivity NCS database directly from the switch or you can create configurations off line NOTE BayStack and Business Policy Switch devices use SNMP to transfer configuration data they do not support Trivial File Transf
4. ck 450 1SX MDA BPS2000 2FX MDA BPS2000 4FX MDA BPS2000 4TX MDA amp Business Policy Switch 2000 VLANS a Script e 1 H In the Palette tab choose a port based protocol based or MAC source address SA based VLAN type In the navigation pane select the VLAN In the Properties tab type a descriptive name to identify the VLAN In the navigation pane expand the switch and select ports to participate in the VLAN 5 Create shortcuts from the ports to the VLAN In the navigation pane select the VLAN ports In the Properties tab configure the VLAN port properties Nortel Networks Optivity NCS ord File Edit View Configuration Tools Server Help amp 22ARRV ses oo KDORz a OF Be Palette Properties Q EP aaministrator 192 32 98 131 m Configuration Data FR rei Bay ASN 192 32 69 206 Basic BPS2000 24T 192 32 100 30 Property 1D Sy BPS2000 24T 192 32 69 242 VLAN Sy BPS2000 24T 192 32 69 242 S wuts ny Trunk 1 ny Trunk 2 my Trunk 3 ny Trunk 3 ny Trunk 5 my Trunk 6 9 Evans VLAN 1 id 1 R ia File Management SEE Ql Saved Search Results Messages Name VLAN 1 Copy the ports and paste them as shortcuts on the VLAN Click the VLAN tab to display the VLAN port properties Configure ports In the navigation pane expand the standalone switch stack unit
5. d Configure an SNMP trap receiver Palette Properties 1 Inthe navigation pane expand the switch and select SNMP a a asic 2 Inthe Properties tab click the green plus sign to add an Property Value J item to the Trap Receivers table Read Only Community String public Read Write Community String public 3 Enter the IP address and community string for each trap receiver Trap Receivers IP Address Community String E Property value Authentication Trap Enabled v av
6. er Protocol TFTP or serial import and export Add stack units and MDAs NOTE You can add switch units to a stack and MDAs to a unit configuration using Optivity NCS Then export that configuration to a stack or unit to which you added the corresponding hardware Alternatively you can install the new unit or MDA in the stack or unit and reimport the configuration through Optivity NCS Reimport will then discover the newly installed unit or MDA It is recommended that you follow this latter method because it is less error prone In the navigation pane select the switch stack Select the unit type that is to be added to the stack from the Palette tab Click the Paste button or double click the unit type that is to be added to the stack Select the newly created unit in the navigation pane and adjust the unit number in the Basic tab in the Properties area Select the newly created unit in the navigation pane and then select the MDA type that is to be added to the new switch unit from the Palette tab Click the Paste button or double click the MDA type that is to be added to the switch Expand the added unit in the navigation pane and then expand the MDA Select a port under the MDA object in the navigation pane Configure Basic VLAN STP and IGMP parameters in the Properties tab as appropriate Palette Properties BayStack 450 1LR MDA BayStack 450 1LX MDA BayStack 450 1SR MDA BaySta
7. sic Basic STG Image Download Wizard N RTEL NETWORKS Copyright December 2000 Nortel Networks All rights reserved Printed in the USA The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Nortel Networks NA Inc 00000 00010000 Configuring BayStack and Business Policy Switches with the Optivity Network Configuration System This card summarizes how to get started using the Optivity Network Configuration System Optivity NCS to configure the BayStack and Business Policy Switches in your network This document is intended for network engineers who have some familiarity with Nortel Networks Layer 2 switches The Business Policy Switch 2000 requires Version 1 0 software The BayStack 350 410 and 450 switches require Ve rsions 1 3 3 1 software Task list The following summarizes an example of the configuration tasks you can complete using Optivity NCS Configure the switch IP address Import or create a switch configuration Add stack units and media dependent adapters MDAs Configure ports Configure virtual local area networks VLANs Configure a multilink trunk