Home

Avaya BayRS Version 13.10 Release Notes

image

Contents

1. Table 7 Standards Supported by Version 13 10 continued Standard Description RFC 1213 MIB for Network Management of TCP IP based Internets RFC 1267 Border Gateway Protocol 3 BGP 3 obsoletes RFC 1163 RFC 1293 Inverse ARP for Frame Relay RFC 1294 Multiprotocol Interconnect over Frame Relay obsoleted by RFC 1490 RFC 1304 Definition of Managed Objects for the SIP Interface Type RFC 1305 Network Time Protocol RFC 1315 Management Information Base for Frame Relay DTEs RFC 1321 MDS Digest Algorithm RFC 1323 TCP Extensions for High Performance RFC 1331 Point to Point Protocol PPP obsoleted by RFC 1661 RFC 1332 PPP Internet Protocol Control Protocol IPCP RFC 1333 PPP Link Quality Monitoring obsoleted by RFC 1989 RFC 1334 PPP Authentication Protocols RFC 1350 The TFTP Protocol Revision 2 RFC 1356 Multiprotocol Interconnect on X 25 and ISDN in the Packet Mode RFC 1376 PPP DECnet Phase IV Control Protocol DNCP RFC 1377 OSI over PPP RFC 1378 PPP AppleTalk Control Protocol ATCP RFC 1390 Transmission of IP and ARP over FDDI Networks RFC 1403 BGP OSPF Interaction RFC 1434 Data Link Switching Switch to Switch Protocol RFC 1483 Multiprotocol Encapsulation over ATM AAL5 RFC 1490 Multiprotocol Interconnect over Frame Relay obsoletes RFC 1294 RFC 1541 Dynamic Host Configuration Protocol RFC 1552 The PPP Internetwork Packet Exchange Control Protoc
2. Syslog Support You can now use the BCC to configure Syslog services on your router For information see the BayRS Version 13 10 Document Change Notice Virtual Router Redundancy Protocol VRRP VRRP enables you to configure router redundancy using virtual routers to protect a network from the irrecoverable failure of an entire router VRRP manages a virtual router which is a software defined object that corresponds to an IP address on a LAN segment A virtual router typically exists on multiple routers running VRRP One of the VRRP routers acts as the master virtual router for an IP address while VRRP routers act as backup virtual routers BayRS 13 10 supports VRRP over LANE For information about VRRP see Configuring VRRP Services WEP over Dial Services You can now configure the WAN Encryption Protocol WEP for dial on demand dial backup and bandwidth on demand circuits for the AN ARN ASN BN and System 5000 routers If you configure WEP to work with dial backup service encrypted data travels over the backup circuit if the primary line fails In addition the maximum NTP timer value has been expanded so that routers using WEP and dial services can now use NTP to synchronize time for WEP security purposes without the overhead of excessive dial connections 301151 C Rev 00 29 Release Notes for BayRS Version 13 10 New Hardware for BayRS 13 10 BayRS Version 13 10 supports the following new hardware ARN E7S S
3. Release Notes for BayRS Version 13 10 BayRS Version 13 10 Site Manager Software Version 7 10 BCC Version 4 10 Part No 301151 C Rev 00 November 1998 ES Bay Networks Where Information Flows n Bay Networks Where Information Flows 4401 Great America Parkway 8 Federal Street Santa Clara CA 95054 Billerica MA 01821 Copyright O 1998 Bay Networks Inc All rights reserved Printed in the USA November 1998 The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Bay Networks Inc The software described in this document is furnished under a license agreement and may only be used in accordance with the terms of that license A summary of the Software License is included in this document Trademarks AN BCN BLN BN FRE Quick2Config and Bay Networks are registered trademarks and Advanced Remote Node ANH ARN ASN BayRS BayStack SPEX System 5000 and the Bay Networks logo are trademarks of Bay Networks Inc Microsoft MS MS DOS Win32 Windows and Windows NT are registered trademarks of Microsoft Corporation All other trademarks and registered trademarks are the property o
4. resulting in log event message number changes for LAN emulation as well You can view the new and modified ATM log event messages in the event database on the World Wide Web or on the BayRS Online Library Version 13 10 CD For information about how to access the event database see Event Database on page 4 2 301151 C Rev 00 Release Notes for BayRS Version 13 10 Upgrading L2TP Configurations If you have a BayRS Version 12 10 configuration file that includes L2TP operating on a router using BayRS Version 13 10 the router automatically upgrades the assigned user network addresses to an L2TP IP interface addresses L2TP IP interface addresses are internal to the router When communicating with the remote user the router associates the user s IP address with an L2TP IP interface address that you configure The user network addresses assigned to Version 12 10 apply to the entire router In Version 13 10 each slot has a unigue L2TP IP address Conseguently if the number of configured L2TP slots is greater than the number of configured assigned user network addresses the router will not be able to upgrade every slot from a Version 12 10 configuration to a Version 13 10 configuration For slots that exceed the number of assigned user network addresses you will need to manually configure L2TP IP interface addresses To do this delete L2TP from the slot then configure a new L2TP interface Each slot must have L2TP IP interface addresse
5. 1 Ethernet port 2 serial ports 1 fractional E1 port with 16 MB DRAM and DCM ansedst 1025 AN ENET TOKEN 1 Ethernet port 2 serial ports 1 token ring port with 16 MB DRAM ansedstc 1092 AN ENET TOKEN with CSU DSU 1 Ethernet port 2 serial ports 1 token ring port continued 12 301151 C Rev 00 Release Notes for BayRS Version 13 10 Table 1 BCC Board Types AN and ANH Modules continued Technician Interface or MIB BCC Board Type Module ID Description ansedsti 1028 AN ENET TOKEN with ISDN 1 Ethernet port 2 serial ports 1 token ring port ansedstj 1123 AN ENET 1 Ethernet port 2 serial ports 3 fractional E1 ports with 16 MB DRAM ansedstjx 1135 AN ENET 1 Ethernet port 2 serial ports 3 fractional E1 ports with 16 MB DRAM and DCM ansedstx 1058 AN ENET TOKEN with DCM 1 Ethernet port 2 serial ports 1 token ring port with 16 MB DRAM ansedsx 1055 AN ENET with DCM 2 Ethernet ports 2 serial ports ansets 1030 AN ENET 1 Ethernet port 3 serial ports with 16 MB DRAM ansetsg 1049 ANH 8 1 Ethernet port 3 serial ports and an 8 port Ethernet hub ansetsh 1032 ANH 12 1 Ethernet port 3 serial ports and a 12 port Ethernet hub ansetst 1031 AN ETS 1 Ethernet port 3 serial ports 1 token ring port antst 1039 AN TOKEN 3 serial ports 1 token ring port Table 2 lists the BLN and BCN board types Table 2 BCC Board Types BLN and BCN
6. Me SU PPONEO AE E ETT 6 Goba zigtepes Me sui ce cavdcnuetiesedaenan cues Drda EA E 7 Internace Protocols Sup Mates narrian ecd br a RR RPG R 7 Getting Started RII m RET KE PET beds qs e 8 Bip xii Jc 8 BCC show Command Documentation sss eere 9 cms MICE EU UU 11 vj pedo EN Fe AF E 17 New Features in Bay RS Version 13 10 uu eummeneemnamine emesisramsssirkasnennsaknnner grkanesn detne 18 BUI MEN 18 301151 C Rev 00 V Backup Management Station Selection sse 18 BCC show config Options UT EE SA WAA sod muse 0 BCC Support for Dial on Demand Sue RE EE TE 20 BOP Fe es RE EE dus 21 Route Flap Dampening EET EE ER aid 21 Configuring EBGP for Route and Traffic Load Barne 21 Data Compression Enhancemenis aa cusan caa tien trad RE ea awaka Saana ada 22 DARPA Mtr A EE 22 DESw PU Type d Device SUppalt oussietoe pud ana ER EM gemene bres ARS 22 Domain Name Server DNS Proxy museet er EE 23 Gaa Routing Aaaa 23 QUIE EI AN UR TT Tm 23 Improved Security je aina aeda EE RET heh bts aboan ANA 23 BEETLE EE EE ER 24 HTTP Server Parametere ii aa 24 IP IRIS LANGU eR 24 Ia 24 DVMRP Policies rae abt bestiis ende EE PE SA PTE AAA 24 Ea pe D 25 se ERE ET RE 25 L2TP Support RFC 1877 ere PASTA ned T 26 Mulier Aso Control U 27 Multiprotocol Label Switching MPLS mmemeumarnneme
7. Message Authentication RFC 2138 Remote Authentication Dial In User Service RADIUS RFC 2139 RADIUS Accounting RFC 2166 Data Link Switching Version 2 0 Enhancements RFC 2205 Resource ReSerVation Protocol RSVP Version 1 Functional Specification RFC 2338 Virtual Router Redundancy Protocol VINES 4 11 BayRS works with the Banyan VINES 4 11 standard BayRS Version 8 10 and later also supports VINES 5 50 sequenced routing 301151 C Rev 00 47 Release Notes for BayRS Version 13 10 Flash Memory Cards Supported You use Personal Computer Memory Card International Association PCMCIA flash memory cards to store the software image and the configuration files in Bay Networks routers Software images for BayRS 13 10 reguire 8 or 16 MB flash cards however you can store configuration files on 4 MB flash cards Table 8 lists the flash memory cards approved for use Table 8 Approved Flash Memory Cards Size Vendor Part Number 4 MB Advanced Micro Devices AMD AMCOOACFLKA 150 AMP 797262 3 797263 2 Centennial FLO4M 20 11119 FLO4M 20 11138 Epson HWB401BNX2 IBM IBM1700400D1DA 25 Intel IMCO04FLSAQ1381 8 MB AMD AMC008CFLKA 150 AMCOOS8CFLKA 200 AMGC008CFLKA 250 AMCOO8DFLKA 150 AMCOO8DFLKA 200 AMCOO8DFLKA 250 Centennial FLO8M 25 11119 01 FLO8M 15 11119 01 FLO8M 20 11138 FLO8M 20 11119 01 Epson HWB801BNXO Intel IMCOOBFLSP Q1422 Centennial Strata Flash
8. Modules Technician Interface or MIB Site Manager BCC Board Type Module ID Model Number Description atmcds3 5120 AG13110115 ATM DS 3 atmce3 5121 AG13110114 ATM E3 atmcoc3mm 4608 AG13110112 ATM STS 3 STM 1 MMF atmcoc3sm 4609 AG13110113 ATM STS 3 STM 1 SMF comp 4353 AG2104037 Octal Sync with 32 context compression daughterboard comp128 4354 AG2104038 Octal Sync with 128 context compression daughterboard continued 301151 C Rev 00 13 Release Notes for BayRS Version 13 10 Table 2 BCC Board Types BLN and BCN Modules continued Technician Interface or MIB Site Manager BCC Board Type Module ID Model Number Description de100 4864 50038 100BASE T Ethernet dst416 40 5740 Dual Sync with token ring dtok 176 5710 Dual token ring enet3 132 5505 Dual Ethernet esaf 236 5531 Dual Sync Dual Ethernet with 2 CAM filters 5532 Dual Sync Dual Ethernet with 6 CAM filters esafnf 232 5431 Dual Sync Dual Ethernet without hardware filters mceliit20 190 AG2111002 120 ohm Dual Port Multichannel E1 MCE1 II for ISDN PRI and Leased Line mcelii75 188 AG2111004 75 ohm Dual Port Multichannel E1 MCE1 II for 75 ohm Leased Line mcti 168 5945 Dual Port MCT1 osync 4352 5008 Octal Sync gef 164 5950 Quad Ethernet with hardware filters genf 162 5450 Quad Ethernet without hardware filters qmctidb15 5377 AG2111007 Quad Port MCT1 DB15 qmctids0a 5378 AG2104052 Quad Port MCT1 DB15 with DS
9. Network System XNS e XMODEM and YMODEM Standards Supported Table 7 lists the Request For Comments RFCs and other standards documents with which Version 13 10 complies BayRS Version 13 10 may support additional standards that are not listed in this table Table 7 Standards Supported by Version 13 10 Standard Description ANSI Digital Hierarchy Supplement to formats specifications T1 107b 1991 ANSI T1 404 DS3 Metallic Interface Specification ANSI X3t9 5 Fiber Distributed Data Interface FDDI Bellcore FR 440 Transport Systems Generic Requirements TSGR Bellcore Asynchronous Digital Multiplexes Requirements and Objectives TR TSY 000009 Bellcore Synchronous DS3 Add Drop Multiplex ADM 3 X Requirements and Objectives TR TSY 000010 FIPS 46 2 Data Encryption Standard DES FIPS 81 DES Modes of Operation ECB CBC IEEE 802 1 Logical Link Control LLC IEEE 802 1Q IEEE 802 1Q VLAN tagging IEEE 802 3 Carrier Sense Multiple Access with Collision Detection CSMA CD IEEE 802 5 Token Ring Access Method and Physical Layer Specifications continued 301151 C Rev 00 43 Release Notes for BayRS Version 13 10 Table 7 Standards Supported by Version 13 10 continued Standard Description IEEE 802 1D Spanning Tree Bridges ITU Q 921 ISDN Layer 2 Specification ITU Q 931 ISDN Layer 3 Specification IT
10. PAD or V 34 console modem daughterboard for the ARN router Use Site Manager to configure these daughterboards Inserting a daughterboard into an AN base module redefines its module ID and board type Table 1 lists the AN and ANH board types Table 1 BCC Board Types AN and ANH Modules Technician Interface or MIB BCC Board Type Module ID Description andeds 1033 AN ENET 2 Ethernet ports 2 serial ports andedsg 1050 ANH 8 2 Ethernet ports 2 serial ports and an 8 port Ethernet hub active for the first Ethernet port andedsh 1035 ANH 12 2 Ethernet ports 2 serial ports and a 12 port Ethernet hub andedst 1034 AN ENET 2 Ethernet ports 2 serial ports 1 token ring port andst 1037 AN TOKEN 2 serial ports 1 token ring port andstc 1091 AN TOKEN with CSU DSU 2 serial ports 1 token ring port andsti 1038 AN TOKEN with ISDN 2 serial ports 1 token ring port ansdsedst 1041 AN ENET TOKEN 1 Ethernet port 2 serial ports 1 token ring port anseds 1024 AN ENET 1 Ethernet port 2 serial ports with 16 MB DRAM ansedsc 1090 AN ENET with CSU DSU 2 Ethernet ports 2 serial ports ansedsf 1100 AN ENET with T1 FT1 2 Ethernet ports 2 serial ports ansedsg 1047 ANH 8 1 Ethernet port 2 serial ports and an 8 port Ethernet hub ansedsgc 1094 ANH 8 with CSU DSU 1 Ethernet port 2 serial ports and an 8 port Ethernet hub continued 301151 C Rev 00 11 Release Notes for Ba
11. Switching MPLS MPLS is an emerging Internet Engineering Task Force IETF standard that is currently in draft form Its primary goal is to integrate label swapping and forwarding with network layer routing Using MPLS a router assigns a label that defines a specific packet stream The router then forwards packets based on these fixed length labels The labels are associated with inbound and outbound interfaces Assigning labels to packets or packet streams increases the transmission speed of your network Protocol Statistics for MPLS The HTTP Server interface for 13 10 contains an additional folder icon for displaying MPLS statistics The following information summarizes these statistics and how to get them using the HTTP Server interface 301151 C Rev 00 27 Release Notes for BayRS Version 13 10 Clicking on Statistics gt Protocols gt MPLS in the navigational frame reveals the following subordinate links MLM Interfaces MLM Sessions MLM Connections LDP Sessions and LDP Information Click on each link to display the statistics for its associated entity For information see Managing Routers Using the HTTP Server To see these statistics Use this path MPLS Label Manager MLM Statistics gt Protocols gt MPLS gt MLM Interfaces interfaces MPLS Label Manager sessions Statistics gt Protocols gt MPLS gt MLM Sessions MPLS Label Manager virtual Statistics gt Protocols gt MPLS gt MLM Connections circ
12. When you transfer that file to the router be sure to rename it as bcc help The Version 13 10 router software is not configured by default to recognize the file name bcc help Event Database With BayRS Version 13 10 you can view the event database on the World Wide Web and the BayRS Online Library Version 13 10 CD To access the event database on the World Wide Web go to http support baynetworks com library tpubs events To access the event database on the BayRS Online Library Version 13 10 CD follow the instructions in the CD booklet The event database includes a search facility that allows you to sort events by entity number event number severity and text of the event message For example you can list only the warning messages for the IPX entity Quick2Config Quick2Config Version 1 3 2 which shipped with BayRS Version 12 20 was the final release of Quick2Config Quick2Config Version 1 3 2 is not compatible with BayRS Version 13 10 or later and there will be no new versions of Quick2Config for these releases Bay Networks will maintain Quick2Config Version 1 3 2 until early 2001 You can continue to configure routers with Site Manager and the BCC 4 301151 C Rev 00 Release Notes for BayRS Version 13 10 SunOS 4 1 4 Support for Site Manager Using the Platforms S Customers using Site Manager with SunOS 4 1 4 must plan to migrate to a supported Solaris OS platform Site Manager Version 7 20 will be the l
13. baynetworks com library tpubs bccfeedbk 301151 C Rev 00 17 Release Notes for BayRS Version 13 10 New Features in BayRS Version 13 10 BayRS Version 13 10 provides the following new features BaySecure FireWall 1 BayRS 13 10 provides support for ISDN interfaces as well as support for backup management stations Backup management stations provide the redundancy required to use BaySecure FireWall 1 in large enterprise networks Using Site Manager you can configure up to two backup management stations Then if your router loses communication with its firewall management station a backup firewall management station automatically establishes communication with the router so that the firewall security remains intact and the logging of firewall statistics continues BaySecure FireWall 1 does not require that a backup management station remain dormant until called into service when a another firewall management station fails A backup management station can simultaneously be a working firewall management station for another firewall Backup Management Station Selection router connects to a backup firewall management station upon termination of the TCP connection with TCP ABORT between the current firewall management station and the router Note When an event like the failure of a LAN prevents communication between the router and the firewall management station the firewall management station closes the TCP connectio
14. creating multiple GRE tunnels dynamically you can configure a maximum of five point to point GRE tunnels In multipoint configurations you can configure 64 GRE tunnels per interface FireWall 1 Redundant Management Scripts Note The information contained in this section supersedes the information contained in the section Transferring Security Policy and Configuration Files found in Chapter 2 of Configuring BaySecure Fire Wall 1 Firewall backup management stations must have the same security policies and configuration files that the primary firewall management station uses Bay Networks has provided script files to make it easy to synchronize firewall management stations The script files enable you to use a single command fwfilex to easily package files associated with a management station s security environment You then manually transfer the files to other firewall management stations You can get these script files from the customer service Web page at http support baynetworks com software Under Bay Networks Routers select Router Software and click on Go The firewall scripts are located under BayRS in Firewall Scripts Note The redundant management scripts do not currently support cross platform redundancy You can use these scripts only when transferring from one Windows NT platform to another or from one UNIX platform to another 301151 C Rev 00 33 Release Notes for BayRS Version 13 10 Preparing a
15. currently in configuration mode The user login and the string 255 255 255 255 indicate to the Site Manager user that this is a BCC session Example Snmp Error Setting File System Action This message appears when a Site Manager user attempts to use File Manager to transfer a file to or from a router that has a BCC user in configuration mode 36 301151 C Rev 00 Release Notes for BayRS Version 13 10 Password Command As a result of the new multiuser access feature the syntax for the password command has been modified as follows password Manager User lt username gt username is the login name for a specific user For the password lt username gt command to work the system manager must first use the BCC interface to define configure user groups and names See Appendix A of Using the Bay Command Console BCC for information about how to complete this task System prompts displayed by the password command remain unchanged Note that the system software immediately encrypts any new password you enter for lt username gt and stores it in encrypted form only NAT Anomalies NAT exhibits the following anomalies in BayRS 13 10 Configuring NAT Dynamically When you configure a local or global interface for NAT in dynamic mode the router returns an SNMP set error However this error does not affect the configuration of the router Deleting NAT from a Router If you delete NAT from a router all pr
16. e Using the BCC e New Features in BayRS Version 13 10 New Hardware for BayRS 13 10 e Guidelines for Working with BayRS Version 13 10 e Operating Limitations e Protocols Supported e Standards Supported e Flash Memory Cards Supported 301151 C Rev 00 1 Release Notes for BayRS Version 13 10 Year 2000 Compliance BayRS Version 13 10 and Site Manager Software Version 7 10 are Year 2000 Compliance Certified by Bay Networks They have successfully passed the Bay Networks Test Procedure which tests conformance to the Bay Networks Year 2000 compliance definition For more information see the Bay Networks Year 2000 Web Site at Attp www baynetworks com year2000 Upgrading to Version 13 10 To upgrade BayRS to Version 13 10 or to upgrade Site Manager software to Version 7 10 see Upgrading Routers to BayRS Version 13 xx in your upgrade package Upgrading ATM Configurations If you are upgrading from a BayRS version earlier than 12 20 and you defined log event traps for ATM ATM signaling or ATM LAN emulation you will need to redefine these traps The ATM ATM signaling and ATM LAN emulation log event messages changed in BayRS Version 12 20 The ATM SIG entity entity 95 no longer exists as a separate entity but has been combined with the ATM entity entity 78 Combining and reorganizing these entities resulted in changes to the ATM log event message numbers New log events were added to the ATM LE entity entity 100
17. plan to install the IPsec software Adding the IPsec File to the BayRS 13 10 Base Kernel To use IPsec you must use Image Builder to add an IPSec file to the BayRS 13 10 base kernel The IPSec file is located on a separate CD which ships with the IPsec feature To install IPsec follow the instructions included on the IPsec CD To use IPsec you do not need to modify or add anything to Site Manager 7 10 34 301151 C Rev 00 Release Notes for BayRS Version 13 10 Multiuser Access To use the multiuser access feature see Using the Bay Command Console BCC and the following guidelines Sharing BCC Multiuser Access Profiles To share user access profiles configured on one router across multiple routers 1 Navigate in BCC configuration mode to a multiuser access context that you want to replicate on another router 2 From the desired context enter the following command show config recursive file lt filename gt 3 Transfer the file from the local router to a target router 4 Log on to the target router and enter BCC configuration mode 5 Use the BCC source command to import access profiles from the transferred file into the device active configuration 6 Exit then reenter the BCC on the target router 7 Enter show config all to see your changes For more information about using the show config and source commands see Using the Bay Command Console BCC BCC Lock Messages Multiuser access includes messa
18. printers You can download Acrobat Reader free from the Adobe Systems Web site www adobe com You can purchase Bay Networks documentation sets CDs and selected technical publications through the Bay Networks Collateral Catalog The catalog is located on the World Wide Web at support baynetworks com catalog html and is divided into sections arranged alphabetically e The CD ROMs section lists available CDs The Guides Books section lists books on technical topics e The Technical Manuals section lists available printed documentation sets Make a note of the part numbers and prices of the items that you want to order Use the Marketing Collateral Catalog description link to place an order and to print the order form 301151 C Rev 00 xi Release Notes for BayRS Version 13 10 How to Get Help For product assistance support contracts information about educational services and the telephone numbers of our global support offices go to the following URL http www baynetworks com corporate contacts In the United States and Canada you can dial 800 2LANWAN for assistance xii 301151 C Rev 00 Release Notes for BayRS Version 13 10 This document contains the latest information about Bay Networks BayRS Version 13 10 These release notes include information about e Year 2000 Compliance e Upgrading to Version 13 10 e Event Database e Quick2Config e SunOS 4 1 4 Support for Site Manager
19. FL08 20 11736 J5 61 16 MB Epson HWB161BNX2 Centennial Strata Flash FL16 20 11736 J5 61 48 301151 C Rev 00
20. FOR A PARTICULAR PURPOSE Licensee is responsible for the security of 301151 C Rev 00 iii its own data and information and for maintaining adeguate procedures apart from the Software to reconstruct lost or altered files data or programs 4 Limitation of liability INNO EVENT WILL BAY NETWORKS OR ITS LICENSORS BE LIABLE FOR ANY COST OF SUBSTITUTE PROCUREMENT SPECIAL INDIRECT INCIDENTAL OR CONSEOUENTIAL DAMAGES OR ANY DAMAGES RESULTING FROM INACCURATE OR LOST DATA OR LOSS OF USE OR PROFITS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE SOFTWARE EVEN IF BAY NETWORKS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT SHALL THE LIABILITY OF BAY NETWORKS RELATING TO THE SOFTWARE OR THIS AGREEMENT EKCEED THE PRICE PAID TO BAY NETWORKS FOR THE SOFTWARE LICENSE 5 Government Licensees This provision applies to all Software and documentation acguired directly or indirectly by or on behalf of the United States Government The Software and documentation are commercial products licensed on the open market at market prices and were developed entirely at private expense and without the use of any U S Government funds The license to the U S Government is granted only with restricted rights and use duplication or disclosure by the U S Government is subject to the restrictions set forth in subparagraph c 1 of the Commercial Computer Software Restricted Rights clause of FAR 52 227 19 and the limitations set out in th
21. OA qtok 256 50021 Quad token ring shssi 225 5295 HSSI smceliit20 191 AG2111001 120 ohm Single Port Multichannel E1 MCE1 II for ISDN PRI and Leased Line smcelii75 189 AG2111003 75 ohm Single Port Multichannel E1 MCE1 II for 75 ohm Leased Line smet1 169 5944 Single Port MCT1e sse 118 5410 Single Sync with Ethernet sync 80 5280 Quad Sync wffddiim 193 5943 Hybrid FDDI with single mode on connector B wffddi1 mf 197 5949 Hybrid FDDI with single mode on connector B and with hardware filters continued 301151 C Rev 00 Release Notes for BayRS Version 13 10 Table 2 BCC Board Types BLN and BCN Modules continuea Technician Interface or MIB Site Manager BCC Board Type Module ID Model Number Description wffddi1s 195 5942 Hybrid FDDI with single mode on connector wffddi1 sf 199 5948 Hybrid FDDI with single mode on connector and with hardware filters wffddi2m 192 5930 Multimode FDDI wffddi2mf 196 5946 Multimode FDDI with hardware filters wffddi2s 194 5940 Single Mode FDDI wffddi2sf 198 5947 Single Mode FDDI with hardware filters Table 3 lists the ASN board types Table 4 lists the ARN board types Table 3 BCC Board Types ASN Modules Technician Interface or MIB BCC Board Type Module ID Description asnqpbri 2560 Quad BRI Net Module denm 1280 Dual Port Ethernet Net Module dmctinm 2944 Dual Port MCT1 Net Modu
22. Otherwise Site Manager the BCC or the Technician Interface will restart after a few minutes Restriction if Signal Ports Settings on a Switch and Router Conflict If you are using a switch with signal ports set to V3 1 be sure to set the signaling setting on the router to V3 1 If you accept the default setting of V3 0 for the router the router will fault repeatedly until you change the setting to V3 1 Restriction When Creating FTP from the BCC From the BCC if you create FTP on the router then delete it and recreate it the BCC will fault In this case you must restart the BCC and create FTP on the router again 301151 C Rev 00 39 Release Notes for BayRS Version 13 10 Restriction When Deleting a Hybrid Mode Permanent Virtual Circuit PVC If you configure SRB on a router do not delete hybrid mode PVCs Otherwise all slots will restart Restriction When Using DLSw APPN Boundary Port with AS400s and Other Adjacent Link Stations Do not configure any explicit APPN adjacent link stations on the DLSw APPN boundary VCCT port unless you are certain that the adjacent link station for example an AS400 will not attempt to connect to the APPN node Otherwise the DLSw APPN boundary VCCT function will fail to operate correctly and the router may restart Restriction When Virtual Channel Connections VCCs Become Inactive On the ARE and 5782 MPE BayRS 13 10 does not release virtual channel connections when they tim
23. PPP Control Protocol IPv6CP Internet Stream Protocol ST2 Layer 2 Tunneling Protocol L2TP Learning Bridge Logical Link Control 2 LLC2 301151 C Rev 00 41 Release Notes for BayRS Version 13 10 Multi Protocol over ATM MPOA Multicast OSPF MOSPF Multiprotocol Label Switching MPLS Native Mode LAN NML Network Time Protocol NTP Open Shortest Path First OSPF Open Systems Interconnection OSI Point to Point Protocol PPP Polled Asynch PAS also called Asynch Passthru over TCP Protocol prioritization Qualified Logical Link Control QLLC RaiseDTR dialup Remote Authentication Dial In User Service RADIUS Resource Reservation Protocol RSVP Router discovery RDISC Router redundancy proprietary Routing Information Protocol RIP Service Advertisement Protocol SAP Simple Network Management Protocol SNMP Source Routing Bridge SRB Source Routing Bridge over ATM permanent virtual circuits PVCs Spanning Tree Switched Multimegabit Data Service SMDS Synchronous Data Link Control SDLC Telnet inbound and outbound Transmission Control Protocol TCP Transparent Bridge Transparent to Source Routing Translation Bridge 42 301151 C Rev 00 Release Notes for BayRS Version 13 10 e Trivial File Transfer Protocol TFTP e User Datagram Protocol UDP e V 25bis dialup e Virtual Network Systems VINES e Virtual Router Redundancy Protocol VRRP X25 with QLLC e Xerox
24. Santa Clara California 95054 8185 LICENSEE ACKNOWLEDGES THAT LICENSEE HAS READ THIS AGREEMENT UNDERSTANDS IT AND AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS LICENSEE FURTHER AGREES THAT THIS AGREEMENT IS THE ENTIRE AND EXCLUSIVE AGREEMENT BETWEEN BAY NETWORKS AND LICENSEE WHICH SUPERSEDES ALL PRIOR ORAL AND WRITTEN AGREEMENTS AND COMMUNICATIONS BETWEEN THE PARTIES PERTAINING TO THE SUBJECT MATTER OF THIS AGREEMENT NO DIFFERENT OR ADDITIONAL TERMS WILL BE ENFORCEABLE AGAINST BAY NETWORKS UNLESS BAY NETWORKS GIVES ITS EXPRESS WRITTEN CONSENT INCLUDING AN EXPRESS WAIVER OF THE TERMS OF THIS AGREEMENT iv 301151 C Rev 00 Contents Preface Bay Networks Technical Publications cccccescceeeeeeeceeeeeeeeceaeeeeeeeeeceaeeeeeseeeeeeeeeatens xi AE RE EE EE xii Release Notes for BayRS Version 13 10 Year 2000 Compliance disais ETT EE ET ee AAA 2 Upgrading io Version eM rie 2 Upgrading ATM Configurations 1er teritur niinus pda lesen tiu i aiaei nae d 2 Upgrading L2TP Configurations sseessss E E E E 3 Upgrading OSPF Glans Aa 3 Uparading Mme BCO Helt File osiensa iaaa aa d UE aa ENEA 3 BE 0 REE a AAA 4 COTE ii aaa 4 SunOS 4 1 4 Support tor Site MBIetBl w enste iueaneiebeddisganssenedksdeen 5 Using ME BOC c n 5 EE srt cache ea betas sien core E mm d d wakila ka auawa Hawa dag 5 Number of BCC Sessions TT TT ET waha obeis ore BOG giz RE ia 6
25. Scripts sse 33 Preparing and Transferring Firewall Files Between Windows NT Platine bene 34 IP Fragmentation Not Supported over GRE Tunnels sss 34 IP Secure P300 EXOGUDSBIG 2e orti nti Oo E ouG Y a uua Eu UG eas dvd 34 Adding the IPsec File to the BayRS 13 10 Base Kernel TNT 34 Museo NESSE e 35 Sharing BCC Multiuser Access Profiles wwwwwwmwmmmamamawwmanwmmawwmaimawima 35 UUME Men ae a E ar 35 EE RE 37 NAT Animales scettr tena PET ee kastene Er vader 37 Configuring NAT Dynaiticaliy m 37 Deleting NAT from a KOMB mau aaa STA Outbound LAN Traffic Filters RE PE addi ide FE re TT bises 38 Protocol Prioritization No Call Filters and TCP Aoniicatione skrue 38 Support l r Satt Flash Card vasmses mmieamenen aaenjjn k en k dvd 38 WEP Bedtabe aaa 38 PP eneste 39 Operating LMS Aaa end Restriction When Deleting ATM H a outer if Signaling Is Enabled 39 Restriction if Signal Ports Settings on a Switch and Router Conflict 39 Restriction When Creating FTP from the BCC EE ER ERR 39 Restriction When Deleting a Hybrid Mode Permanent Virtual Circuit PVC M 40 Restriction When Using DLSw APPN Boundary Port with AS400s and Other s ger Sci 2 40 301151 C Rev 00 vii Restriction When Virtual Channel Connections VCCs Become Inact
26. U X 25 Interface between data terminal equipment DTE and data circuit terminating equipment DCE for terminals operating in the packet mode and connected to public data networks by dedicated circuits RFC 768 User Datagram Protocol UDP RFC 791 Internet Protocol IP RFC 792 Internet Control Message Protocol ICMP RFC 793 Transmission Control Protocol TCP RFC 813 Window and Acknowledgment Strategy in TCP RFC 826 Ethernet Address Resolution Protocol RFC 827 Exterior Gateway Protocol EGP RFC 854 Telnet Protocol Specification RFC 855 Telnet Option Specification RFC 856 Telnet Binary Transmission RFC 857 Telnet Echo Option RFC 858 Telnet Suppress Go Ahead Option RFC 859 Telnet Status Option RFC 860 Telnet Timing Mark Option RFC 861 Telnet Extended Options List Option RFC 863 Discard Protocol RFC 877 Transmission of IP Datagrams over Public Data Networks RFC 879 TCP Maximum Segment Size and Related Topics RFC 888 STUB Exterior Gateway Protocol RFC 894 Transmission of IP Datagrams over Ethernet Networks RFC 896 Congestion Control in IP TCP Internetworks RFC 903 Reverse Address Resolution Protocol RFC 904 Exterior Gateway Protocol Formal Specification RFC 919 Broadcasting Internet Datagrams continued 44 301151 C Rev 00 Release Notes for BayRS Version 13 10 Table 7 Standards Supported by Version 13 10 conti
27. You can use BCC commands to configure the following interface protocols ARP e ATM e Dial backup Dial on demand e DVMRP e Frame relay multiline not supported e IGMP P e PX 301151 C Rev 00 Release Notes for BayRS Version 13 10 e OSPF e PPP certain line parameters only no multiline or multilink supported e Proprietary Standard Point to Point e RIP e Router Discovery RDISC Getting Started gt Caution BCC configuration and source commands make immediate changes to the active device configuration Read about the source command in Using the Bay Command Console BCC Before using the BCC save your configuration files by copying them onto the same flash memory card using new file names To start the BCC enter bcc at the Technician Interface prompt To display the online instructions for new BCC users enter help learning bcc at the bcc prompt To display a full summary of the Help features of the BCC interface just enter the help command at any BCC prompt For more information about how to use the BCC interface see Using the Bay Command Console BCC For instructions on using the BCC to add and change configurable services see the documentation for that service Deleting Interfaces with the BCC Before using the BCC to delete an interface make sure that you did not use Site Manager to configure the interface with a protocol that the BCC does not recognize If you did use Site Ma
28. andard DES to encrypt the packet payload and Message Digest 5 MDS to provide authentication Because ESP allows the user to implement null encryption ESP provides the same capabilities as the Authentication Header AH protocol For this reason Bay Networks supports only ESP not AH For BayRS Version 13 10 key management is manual 301151 C Rev 00 25 Release Notes for BayRS Version 13 10 IPsec supports tunnel mode and transport mode the Bay Networks implementation of IPsec supports only tunnel mode For BayRS Version 13 10 the Bay Networks implementation of IPsec provides network layer layer 3 security services for WAN communications on AN ARN ASN and System 5000 routers For more information about IPsec and instructions on how to configure it on a router see Configuring IP Security Services L2TP Support RFC 1877 Bay Networks has implemented RFC 1877 IP Control Protocol IPCP Name Server Addresses for Layer 2 Tunneling Protocol L2TP connections This name server address NSA feature enables remote hosts dialing in to a Bay Networks router acting as an L2TP network server LNS to obtain NSAs from either the LNS or a RADIUS server To use the NSA feature users at remote sites configuring their dial up connections in Windows 95 Windows 98 or Windows NT must specify that their connections will use Server assigned name server addresses to indicate that a remote server provides NSAs If a user d
29. ast release that will ship with SunOS support Site Manager releases later than 7 20 will not work with SunOS but will continue to work with Solaris and other supported operating systems BCC The Bay Command Console BCC is a command line interface for configuring Bay Networks devices It also supports Technician Interface commands and scripts Before using the BCC refer to the following sections listing the platforms protocols interfaces and hardware modules that the BCC supports upported The BCC runs on AN ANH ARN ASN 9 System 5000 and BN platforms including ARE FRE and FRE 2 processor modules Each slot must have e 16 MB of dynamic RAM DRAM e 2 MB of free memory available when you start the BCC If you try to start the BCC with insufficient DRAM or free memory on a slot the BCC returns an error message In that case use Site Manager instead of the BCC Number of BCC Sessions You can open one BCC session per slot in read write configuration mode Other users can open additional BCC sessions in read only nonconfiguration mode depending on the memory resources available on the slot supporting your login session When memory requirements are insufficient to support additional BCC sessions on a login slot the system displays the following message BCC requires 2MB of free memory Current available memory is lt current_available gt bytes 301151 C Rev 00 Release Notes for BayRS Versio
30. e out To maintain the availability of VCCs for new activities configure a LAN emulation client LEC other than the router to release the inactive VCCs Protocols Supported BayRS Version 13 10 supports the following bridging routing protocols and router configuration features e Advanced Peer to Peer Networking APPN e AppleTalk and AppleTalk Update Routing Protocol AURP e Asynchronous transfer mode ATM e ATM Data Exchange Interface ATM DXI e ATM Half Bridge AHB e ATM LAN Emulation 802 3 and 802 5 Bandwidth Allocation Protocol BAP e Binary Synchronous Communication Type 3 BSC3 40 301151 C Rev 00 Release Notes for BayRS Version 13 10 Bisync over TCP BOT Bootstrap Protocol BootP Border Gateway Protocol BGP 3 and BGP 4 Classless interdomain routing CIDR Data compression WCP and Hi fn Data link switching DLSw DEC net Phase IV Distance Vector Multicast Routing Protocol DVMRP Dynamic Host Configuration Protocol DHCP Encryption WEP proprietary Exterior Gateway Protocol 2 EGP 2 File Transfer Protocol FTP Frame relay PVC SVC HP Probe Hypertext Transfer Protocol HTTP Integrated Services Digital Network ISDN Interface redundancy proprietary Internet Control Message Protocol ICMP Internet Gateway Management Protocol IGMP Internet Packet Exchange IPX Internet Protocol IP Internet Protocol Version 6 IPv6 IPsec Encapsulating Security Payload ESP IPv6
31. eviously configured instances of static entries will remain in the router MIB You can delete the instances using the Technician Interface 301151 C Rev 00 37 Release Notes for BayRS Version 13 10 Outbound LAN Traffic Filters When implementing outbound traffic filters for LAN protocols note that in some configurations the filters may cause a decline in throughput performance For LAN circuits where the forwarding rate of the router is critical you should monitor the throughput performance after configuring outbound traffic filters If you notice an unacceptable performance degradation try using inbound traffic filters Protocol Prioritization No Call Filters and TCP Applications Using a no call filter that applies to any TCP application can cause TCP to retransmit the filtered packet When two routers running a TCP application are connected using a demand line and the demand line becomes inactive the TCP application remains inactive If a demand line configured with a no call filter goes down the no call filter drops any TCP packets it receives Because TCP never receives an acknowledgment for transmitting its packets the TCP application continues to retransmit packets until the connection eventually times out and the application stops operating Note No call filters are specific to dial services For additional information about traffic filters and protocol prioritization see Configuring Traffic Filters and Protocol Pri
32. f their respective owners Restricted Rights Legend Use duplication or disclosure by the United States Government is subject to restrictions as set forth in subparagraph c 1 Gi of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 Notwithstanding any other license agreement that may pertain to or accompany the delivery of this computer software the rights of the United States Government regarding its use reproduction and disclosure are as set forth in the Commercial Computer Software Restricted Rights clause at FAR 52 227 19 Statement of Conditions In the interest of improving internal design operational function and or reliability Bay Networks Inc reserves the right to make changes to the products described in this document without notice Bay Networks Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein Portions of the code in this software product may be Copyright O 1988 Regents of the University of California All rights reserved Redistribution and use in source and binary forms of such portions are permitted provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation advertising materials and other materials related to such distribution and use acknowledge that such portions of the software were developed by the University of California Berkeley T
33. from the date Software is first shipped to Licensee Bay Networks will replace defective media at no charge if it is returned to Bay Networks during the warranty period along with proof of the date of shipment This warranty does not apply if the media has been damaged as a result of accident misuse or abuse The Licensee assumes all responsibility for selection of the Software to achieve Licensee s intended results and for the installation use and results obtained from the Software Bay Networks does not warrant a that the functions contained in the software will meet the Licensee s requirements b that the Software will operate in the hardware or software combinations that the Licensee may select c that the operation of the Software will be uninterrupted or error free or d that all defects in the operation of the Software will be corrected Bay Networks is not obligated to remedy any Software defect that cannot be reproduced with the latest Software release These warranties do not apply to the Software if it has been i altered except by Bay Networks or in accordance with its instructions ii used in conjunction with another vendor s product resulting in the defect or iii damaged by improper environment abuse misuse accident or negligence THE FOREGOING WARRANTIES AND LIMITATIONS ARE EXCLUSIVE REMEDIES AND ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS
34. ges that identify which user has exclusive read write access to the device configuration The additional lock messages take the generic form read write mode in use by lt login id gt from console ip address gt use force to override Example read write mode in use by testuserl from 192 168 133 99 use force to override 301151 C Rev 00 35 Release Notes for BayRS Version 13 10 This message appears when a user in BCC config mode is logged in using a telnet session The message contains the user s login name and the IP address of the workstation from which the user initiated the session Example read write mode in use by Manager from console use force to override This message appears when the user in BCC config mode is logged in at the console connected to the router Example SNMP user from 192 168 133 99 has the configuration locked use force to override This message appears when an SNMP station has locked exclusive read write access to the device configuration The message identifies SNMP and the IP address of the workstation from which that user initiated the session For information on SNMP locking see Configuring SNMP BootP DHCP and RARP Services Example SNMP General Set Error Machine is currently locked by manager 255 255 42554255 This message appears when a Site Manager user attempts to open a dynamic configuration session on the same box with a BCC user
35. he name of the University may not be used to endorse or promote products derived from such portions of the software without specific prior written permission SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED AS IS AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE In addition the program and information contained herein are licensed only pursuant to a license agreement that contains restrictions on use and disclosure that may incorporate by reference certain limitations and notices imposed by third parties 301151 C Rev 00 Bay Networks Inc Software License Agreement NOTICE Please carefully read this license agreement before copying or using the accompanying software or installing the hardware unit with pre enabled software each of which is referred to as Software in this Agreement BY COPYING OR USING THE SOFTWARE YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT THE TERMS EKPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS UNDER WHICH BAY NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE If you do not accept these terms and conditions return the product unused and in the original shipping container within 30 days of purchase to obtain a credit for the full purchase price 1 License Grant Bay Networks Inc Bay Networks grants the end user of the Software Licensee a personal nonexclusive nontra
36. hough all looping terminates and the module hardware resets Restarting the router turns the LED off However this action is not necessary for proper operation of the DSU CSU interface Network Booting on DSU CSU Interfaces AN and ANH DSU CSU interfaces do not support network booting in BayRS Version 13 10 The ARN DSU CSU supports network booting only over interfaces configured for 64 Kb s Clear Channel service ARN Router Not a Supported DVS RADIUS Client The ARN router is not a supported DVS RADIUS client BayRS Version 13 10 Flash Memory Requirements BayRS Version 13 10 software ships on the following flash memory cards Platform Flash Memory Required Associated Software Suites AN ANH 8 or 16 MB corp suite ip access office suite ARN 8 or 16 MB corp suite ip access office suite ASN 8 or 16 MB corp suite lan suite system suite wan suite BN 8 or 16 MB atm suite corp suite lan suite system suite vnr suite wan suite System 5000 8 or 16 MB corp suite lan suite system suite vnr suite wan suite Configuring PU 4 and SDLC Link Stations If you use PU 4 devices with SDLC and modulo 128 set the SDLC parameters MAXOUT and MAXIN to 127 You see these parameters in the SDLC Link Station Configuration window For instructions on setting these parameters see Configuring SDLC Services 32 301151 C Rev 00 Release Notes for BayRS Version 13 10 Creating Multiple GRE Tunnels When
37. is license for civilian agencies and subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause of DFARS 252 227 7013 for agencies of the Department of Defense or their successors whichever is applicable 6 Use of Software in the European Community This provision applies to all Software acquired for use within the European Community If Licensee uses the Software within a country in the European Community the Software Directive enacted by the Council of European Communities Directive dated 14 May 1991 will apply to the examination of the Software to facilitate interoperability Licensee agrees to notify Bay Networks of any such intended examination of the Software and may procure support and assistance from Bay Networks 7 Term and termination This license is effective until terminated however all of the restrictions with respect to Bay Networks copyright in the Software and user manuals will cease being effective at the date of expiration of the Bay Networks copyright those restrictions relating to use and disclosure of Bay Networks confidential information shall continue in effect Licensee may terminate this license at any time The license will automatically terminate if Licensee fails to comply with any of the terms and conditions of the license Upon termination for any reason Licensee will immediately destroy or return to Bay Networks the Software user manuals and all copies Bay Networks is not liable t
38. ive 40 Protocols Supported KE TT oid T T T AAA 40 FAT AN ER E 43 Flash Memory Cards SUpPporled ui wk ak VR jakkene 48 viii 301151 C Rev 00 Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 301151 C Rev 00 Tables BCC Board Types AN and ANH Modules esee 11 BCC Board Types BLN and BCN Modules eene 13 BCC Board pes ASN NOQUIGE Ia 15 BCC Board Types ARN Modules eese 16 BCC Board Types System 5000 Modules T T AZ 64 MB ATM Routing Engine Specifications wwwwwww mmmmmememena 30 Standards Supported by Version 18 10 43 Approved Flash Memory Garde aaa 48 Preface BayRS Version 13 10 is a major software release that includes new features functionality and significant software changes made since BayRS Version 13 01 These release notes contain guidelines for using BayRS Version 13 10 Bay Networks Technical Publications You can now print Bay Networks technical manuals and release notes free directly from the Internet Go to support baynetworks com library tpubs Find the Bay Networks product for which you need documentation Then locate the specific category and model or version for your hardware or software product Using Adobe Acrobat Reader you can open the manuals and release notes search for the sections you need and print them on most standard
39. le dsnmin 1540 Dual Port Synchronous Net Module dsnminisdn 1588 ISDN BRI Dual Sync Net Module dtnm 2048 Dual Port Token Ring Net Module mceinm 2816 MCE1 Net Module mmasmbdas 1833 Hybrid PHY B FDDI Net Module mmfsddas 1793 Multimode FDDI Net Module qsyncm 1664 Quad Port Synchronous Net Module se100nm 2304 100BASE T Ethernet Net Module shssinm 3584 HSSI Net Module smammbdas 1825 Hybrid PHY A FDDI Net Module smfsddas 1801 Single Mode FDDI Net Module spex 512 SPEX Net Module spexhsd 769 SPEX Hot Swap Net Module 301151 C Rev 00 15 Release Notes for BayRS Version 13 10 Table 4 BCC Board Types ARN Modules Technician Interface or MIB BCC Board Type Module ID Description arn7sync 8873 ARN Seven port Serial Expansion Module arndcsu 8768 ARN 56 64K DSU CSU Adapter Module arne7sync 8872 ARN Seven Port Serial Expansion Module with 1 Ethernet Port arnentsync 8864 ARN Ethernet and Tri Serial Expansion Module arnfe1 8780 E1 FE1 DSU CSU Adapter Module arnft1 8776 T1 FT1 DSU CSU Adapter Module arnis 8784 ARN ISDN BRI S T Adapter Module arnisdnu 8800 ARN ISDN BRI U Adapter Module arnisdnu 8880 ARN Token Ring and Tri Serial Expansion Module arnmbenx10 8896 ARN Ethernet Base Module xxMB DRAM with DCM arnmbsen 8720 ARN Ethernet Base Module with 0 4 8 16 or 32 DRAM arnmbstr 8704 ARN Token Ring Base Module with 0 8 16 or 32 MB DRAM arnpbenx10 8928 ARN Ethernet Expansion Mod
40. minnrmvvvruvsurnaonneskerannntdkekkn 27 Protocol Statisties MA ia 27 Vig se EE EE EE 28 MPOA Enhancements sse ETT TOT T MEM arkene 28 PVC Operations and Manii IA 29 SE ea aduer E E T ced SU end EN daa ads 29 Virtual Router Redundancy Protocol VRRP IAA TN bukkene REE 29 WEP FE Dial F R sakna dannet 29 Now Hardware Tor Bay RS 13 10 uoce teet eros taces Fen kusk S Rr as Ead RU ad 30 KE e M 30 BCC Support for the FRE2 060E Processor Module with Advanced Compression Fr EE EE Betis EN KANE ieee 30 BCC Support for the FRE 2 060E NG Module REE EE TR 30 vi 301151 C Rev 00 Support tor 64 MB ATM Routing Engine Liuius erre nt rrr a nike 30 Guidelines for Working with BayRS Version 13 10 sssssssssseeeeeee 31 Amendment to Configuring PPP Services uiuis tecece eere pt eese cedes edere ce iu pk Ka 31 ANANH ard ARN iii 1 ir pen ab cra erba pret rae en a PO FE A RE 31 Allocating Memory on ARN Routers TT wadi DSU CSU Test LED Remains On After Reset rrrnnannvnnnnnvvnnnnvnnnonnvnnnnrrnnnnnvenennr 32 Network Booting on DSU CSU Interfaces essen 32 ARN Router Not a Supported DVS RADIUS Client EN YAA ee C BayRS Version 13 10 Flash Memory Requirements wwssmmwwamwamwam ama 32 Configuring PU 4 and SDLC Link Stations 1 erattu 32 acp Schi C n 393 FireWall 1 Redundant Management
41. n 13 10 All BCC sessions are mutually ezclusive If you make a change in a BCC session in read write mode this change does not appear in another BCC session BCC Help Initialization Obtaining a response from a BCC help reguest may reguire an initialization time of about one minute This initialization occurs only when issuing the first help command after booting the device Subseguent reguests for BCC help information take only one or two seconds Interfaces Supported You can use BCC commands to configure the following physical virtual interfaces e ATM e Console e DCM e DSU CSU e Ethernet FDDI FEI FTI HSSI e SDN BRI e MCEI MCTI e Serial synchronous e Token ring e Virtual referred to in Site Manager as Circuitless IP Tables 1 through 5 on pages 11 to 16 list the link and net modules that the BCC supports 6 301151 C Rev 00 Release Notes for BayRS Version 13 10 Global Protocols Supported You can use BCC commands to configure the following global services e Access multiuser access accounts ARP e BGP including accept and announce policies DNS e DVMRP e FTP e HTTP e IGMP e IP including access policies static routes and adjacent hosts e PX including static netbios route e J PXWAN e NTP e OSPF including accept and announce policies e RIP including accept and announce policies e SNMP e Syslog e Telnet TFTP Interface Protocols Supported
42. n from its end when data does not flow from the idle TCP connection However the router does not close the TCP connection from its end for a period of time determined by the TCP keepalive timer The TCP keepalive timer in the firewall application on the router periodically checks the TCP connection before the router aborts the idle TCP connection 301151 C Rev 00 Release Notes for BayRS Version 13 10 When a firewall management station becomes disconnected from the router the router begins a round robin selection process where it continuously tries to connect to another management station at 40 second intervals The order of the round robin selection is primary first backup and then second backup management station For ezample if the connection between the router and the primary management station fails the router tries to connect to the first backup management station If the router connects to the first backup management station and that connection later fails the router tries to connect to the second backup management station before it tries to connect to the primary management station again 301151 C Rev 00 19 Release Notes for BayRS Version 13 10 BCC show config Options The BCC show config command has new options and output behavior starting with the 13 10 Release of BayRS as follows show config show config lt BCC instance ID gt Command Options combine to customize show config output compac
43. nager to delete the interface 301151 C Rev 00 Release Notes for BayRS Version 13 10 BCC show Command Documentation The following table maps each BCC show command to the document that contains its description BCC show command Where Documented show access Using the Bay Command Console BCC show atm Configuring ATM and MPLS Services show bgp unavailable show bri Configuring Dial Services show classical ip Configuring ATM and MPLS Services show config Using the Bay Command Console BCC show console show dial Using the Bay Command Console BCC Configuring Dial Services show dns Configuring IP Utilities show dsucsu Configuring WAN Line Services show dsx3 Configuring ATM and MPLS Services show dvmrp unavailable show ethernet Configuring Ethernet FDDI and Token Ring Services show fddi Configuring Ethernet FDDI and Token Ring Services show frame relay Configuring Frame Relay Services show ft1e1 show ftp Configuring WAN Line Services Configuring IP Utilities show hardware Using the Bay Command Console BCC show hifn Configuring Data Compression Services show hssi Configuring WAN Line Services show http Managing Routers Using the HTTP Server show hwcomp Configuring Data Compression show igmp unavailable show interface Using the Bay Command Console BCC show ip
44. nchronous modem control character map Maximum receive unit MRU e RFC 1661 MRU compliance e Authentication protocols These features are relevant only for PPP dial connections To customize these connections using the BCC you must access the PPP dial interface or dial circuit object For instructions on how to customize these features see Configuring Dial Services Specifically to customize all features except the authentication protocols see Chapter 9 Modifying PPP Dial Interfaces in a Pool To customize the authentication protocols CHAP and PAP see Chapter 12 Modifying PPP Authentication Information AN ANH and ARN Guidelines Note the following operational guidelines when using AN ANH or ARN routers Allocating Memory on ARN Routers Although you can change the default memory allocation on other Bay Networks router platforms the ARN platform does not support this buffer carving feature On the ARN Site Manager does not support the Admin Kernel Configuration option and the Technician Interface does not support the set command for wfKernCfgParamEntry objects Attempting to set wfKernCfgParamGlobMem on the ARN results in a warning message 301151 C Rev 00 31 Release Notes for BayRS Version 13 10 DSU CSU Test LED Remains On After Reset The ARN DSU CSU Test LED properly goes on when the interface enters test or loopback mode However the LED remains on after resetting the DSU CSU module even t
45. nd Transferring Firewall Files Between Windows NT Platforms When you complete the following steps the Windows NT platforms are synchronized and ready to be used in a redundant firewall management configuration 1 Ensure that the files zip exe unzip exe and fwfilex cmd reside in the FireWall 1 bin directory typically WINNT F WI Win 2 Enter the command fwfilex i lt filename gt to package the firewall environment that is firewall policies logs objects and so on into 2 single file 3 Using FTP copy or another transfer utility manually transfer the file lt filename gt from one Windows NT machine to another 4 On the destination machine use the command fwfilex 0 lt filename gt to unpackage the firewall environment IP Fragmentation Not Supported over GRE Tunnels IP packets will not be fragmented when encapsulated at the tunnel ingress point If necessary you can set MTU sizes to values large enough to prevent fragmentation on relevant interfaces on the GRE tunnel ingress router Alternatively you can configure your system to send MTU sizes less than the MTU sizes of the relevant interfaces on the GRE tunnel ingress router IP Security IPsec Executable To use the DES 56 IPsec Option to perform IPsec ESP tunnel mode encryption and authentication you must purchase a separate CD containing the cryptographic API executable capi exe for BayRS 13 10 software Purchase this CD for the router platform on which you
46. nels are manually configured on the routers For information about GRE see Chapter 13 of Configuring IP Services HTTP Server For Version 13 10 the HTTP Server contains many enhancements that improve performance but that are not otherwise visible to the user Two key elements that affect what the user sees are improved security and the ability to access the monitored router using its domain name instead of its IP address Improved Security While continuing to support basic access authentication using a user name and password Version 13 10 also implements RFC2069 compliant digest authentication based on a challenge response model Most browsers however do not yet support digest authentication Although you can configure digest authentication for Bay Networks routers leave this parameter at the default setting of basic authentication 301151 C Rev 00 23 Release Notes for BayRS Version 13 10 Domain Name Access By setting the Domain Name parameter you can access the server by a domain name rather than by IP address Set the Domain Name parameter to the domain name that a DNS lookup would return for the router The name can consist of any valid string of characters that constitute a domain name HTTP Server Parameters The HTTP Server has removed two obsolete configuration parameters cache aging timer and max cached archives and added two new parameters authentication and domain name Uses of the new parameters are desc
47. nsferable license a to use the Software either on a single computer or if applicable on a single authorized device identified by host ID for which it was originally acquired b to copy the Software solely for backup purposes in support of authorized use of the Software and c to use and copy the associated user manual solely in support of authorized use of the Software by Licensee This license applies to the Software only and does not extend to Bay Networks Agent software or other Bay Networks software products Bay Networks Agent software or other Bay Networks software products are licensed for use under the terms of the applicable Bay Networks Inc Software License Agreement that accompanies such software and upon payment by the end user of the applicable license fees for such software 2 Restrictions on use reservation of rights The Software and user manuals are protected under copyright laws Bay Networks and or its licensors retain all title and ownership in both the Software and user manuals including any revisions made by Bay Networks or its licensors The copyright notice must be reproduced and included with any copy of any portion of the Software or user manuals Licensee may not modify translate decompile disassemble use for any competitive analysis reverse engineer distribute or create derivative works from the Software or user manuals or any copy in whole or in part Except as expressly provided in this Agreement Licensee may n
48. nued Standard Description RFC 922 Broadcasting Internet Datagrams in Subnets RFC 925 Multi LAN Address Resolution RFC 950 Internet Standard Subnetting Procedure RFC 951 Bootstrap Protocol RFC 959 File Transfer Protocol RFC 994 Protocol for Providing the Connectionless mode Network Service RFC 1009 Requirements for Internet Gateways RFC 1027 Using ARP to Implement Transparent Subnet Gateways RFC 1042 Transmission of IP over IEEE 802 Networks RFC 1058 Routing Information Protocol RFC 1075 Distance Vector Multicast Routing Protocol DVMRP RFC 1076 Redefinition of Managed Objects for IEEE 802 3 Repeater Devices AN hubs only RFC 1079 Telnet Terminal Speed Option RFC 1084 BOOTP Vendor Information Extensions RFC 1091 Telnet Terminal Type Option RFC 1108 Security Options for the Internet Protocol RFC 1112 Host Extensions for IP Multicasting Appendix I Internet Group Management Protocol RFC 1116 Telnet Line mode Option RFC 1139 Echo Function for ISO 8473 RFC 1155 Structure and Identification of Management Information for TCP IP based Internets RFC 1157 Simple Network Management Protocol SNMP RFC 1163 BGP 2 obsoleted by RFC 1267 RFC 1164 Application of BGP in the Internet RFC 1166 Internet Numbers RFC 1188 Proposed Standard for the Transmission of IP over FDDI RFC 1191 Path MTU Discovery RFC 1209 Transmission of IP Datagrams over SMDS RFC 1212 Concise MIB Definitions continued 301151 C Rev 00 45 Release Notes for BayRS Version 13 10
49. o Licensee for damages in any form solely by reason of the termination of this license 8 Export and Re export Licensee agrees not to export directly or indirectly the Software or related technical data or information without first obtaining any required export licenses or other governmental approvals Without limiting the foregoing Licensee on behalf of itself and its subsidiaries and affiliates agrees that it will not without first obtaining all export licenses and approvals required by the U S Government 1 export re export transfer or divert any such Software or technical data or any direct product thereof to any country to which such exports or re exports are restricted or embargoed under United States export control laws and regulations or to any national or resident of such restricted or embargoed countries or ii provide the Software or related technical data or information to any military end user or for any military end use including the design development or production of any chemical nuclear or biological weapons 9 General If any provision of this Agreement is held to be invalid or unenforceable by a court of competent jurisdiction the remainder of the provisions of this Agreement shall remain in full force and effect This Agreement will be governed by the laws of the state of California Should you have any questions concerning this Agreement contact Bay Networks Inc 4401 Great America Parkway P O Box 58185
50. oes not select the Server assigned name server addresses setting the connection uses the NSAs that the user enters in the TCP IP Settings window The NSA feature is disabled for the connection When users specify that they want to use server assigned NSAs they should not enter primary and secondary domain name server DNS and WINS name server addresses also called NetBIOS name server addresses or NBNS addresses Instead when a user dials in the LNS or RADIUS server automatically assigns name server addresses for the connection If a name server address changes the network administrator can change it once at the LNS or RADIUS server site every remote user is not required to enter a new address For information about L2TP see the BayRS Version 13 10 Document Change Notice 26 301151 C Rev 00 Release Notes for BayRS Version 13 10 Multiuser Access Control Previous versions of the BCC included two user logins e Manager login that allowed you to enter any system level command and allowed read write access to the device configuration e User login that allowed you to enter only user level system commands and allowed read only access to the device configuration Multiuser access allows you to configure multiple user logins each with a distinct user name password and privilege levels to access the router simultaneously For information about multiuser access control see Using the Bay Command Console BCC Multiprotocol Label
51. of network reachability information that can be caused by an unstable route is commonly referred to as route flap Route flap dampening is a technique for suppressing information about unstable routes BayRS Version 13 10 supports dampening of unstable EBGP routes To monitor BGP for route flaps you set the route dampening parameter on a BGP accept policy that matches the route BGP creates a penalty value for the route and sets the value to 0 BGP increments the penalty each time the route flaps BGP provides a route flap dampening template that allows you to control the way BGP evaluates a route s penalty and how based on the penalty it decides to suppress or unsuppress the route For information about BGP route flap dampening see Chapter 8 of Configuring IP Services Configuring EBGP for Route and Traffic Load Balancing EBGP route balancing and traffic load balancing are two techniques that allow an EBGP speaker to distribute routes to the same destination among multiple equal cost paths In both techniques EBGP uses equal cost multipath ECMP routes submitted statically to the IP routing table You can configure an EBGP speaker to use ECMP static routes in the IP routing table for route balancing and traffic load balancing For information about configuring EBGP for route balancing and traffic load balancing see Chapter 8 of Configuring IP Services 301151 C Rev 00 21 Release Notes for BayRS Version 13 10 Data Compre
52. ol IPXCP RFC 1577 Classical IP and ARP over ATM RFC 1583 OSPF Version 2 RFC 1585 MOSPF Analysis and Experience RFC 1634 Novell IPX over Various WAN Media IPXWAN continued 46 301151 C Rev 00 Release Notes for BayRS Version 13 10 Table 7 Standards Supported by Version 13 10 continuea Standard Description RFC 1638 PPP Bridging Control Protocol BCP RFC 1654 Border Gateway Protocol 4 BGP 4 obsoleted by RFC 1771 RFC 1661 Point to Point Protocol PPP obsoletes RFC 1331 RFC 1662 PPP in HDLC like Framing RFC 1717 PPP Multilink Protocol MP obsoleted by RFC 1990 RFC 1755 Signaling Support for IP over ATM RFC 1757 Remote Network Monitoring Management Information Base RMON for AN ANH and ARN equipped with data collection module only RFC 1762 PPP Banyan VINES Control Protocol BVCP RFC 1763 PPP DECnet Phase IV Control Protocol DNCP RFC 1764 PPP XNS IDP Control Protocol XNSCP RFC 1771 Border Gateway Protocol 4 BGP 4 obsoletes RFC 1654 RFC 1795 Data Link Switching Switch to Switch Protocol Version 1 RFC 1819 Internet Stream Protocol Version 2 RFC 1974 PPP Stac LZS Compression Protocol RFC 1989 PPP Link Quality Monitoring obsoletes RFC 1333 RFC 1990 PPP Multilink Protocol MP obsoletes RFC 1717 RFC 2068 HTTP Version 1 1 RFC 2069 An extension to HTTP Digest Access Authentication RFC 2104 HMAC Keyed Hashing for
53. oritization Support for Strata Flash Card BayRS Version 13 10 supports the Strata Flash card on AN ANH ARN ASN and BN routers For full details about flash cards that BayRS 13 10 supports see Flash Memory Cards Supported on page 48 WEP Executable To use the DES 40 WAN Encryption Option or DES 56 WAN Encryption Option to perform PPP or FR layer 2 encryption you must purchase a separate CD containing the WEP executable wep exe for BayRS 13 10 software To install WEP on a router you must first add the WEP executable to your BayRS 13 10 base kernel using Image Builder in Site Manager 38 301151 C Rev 00 Release Notes for BayRS Version 13 10 You can purchase two WEP executables based on the key size a 40 bit version and a 56 bit version which are included on separate CDs You must purchase three CDs when ordering the WEP protocol for BayRS software Base BayRS 13 10 CD which contains no WEP functions e 40 bit WEP CD which contains the 40 bit executable file e 56 bit WEP CD which contains the 56 bit executable file To configure WEP you do not need to modify Site Manager X 25 PVCs BayRS Version 13 10 software supports X 25 PVCs for X 25 IPEX Gateway services only Operating Limitations Be aware of the following limitations when using BayRS 13 10 Restriction When Deleting ATM from a Router if Signaling Is Enabled Do not delete ATM from a router if you enabled signaling on an ATM circuit
54. ot copy or transfer the Software or user manuals in whole or in part The Software and user manuals embody Bay Networks and its licensors confidential and proprietary intellectual property Licensee shall not sublicense assign or otherwise disclose to any third party the Software or any information about the operation design performance or implementation of the Software and user manuals that is confidential to Bay Networks and its licensors however Licensee may grant permission to its consultants subcontractors and agents to use the Software at Licensee s facility provided they have agreed to use the Software only in accordance with the terms of this license 3 Limited warranty Bay Networks warrants each item of Software as delivered by Bay Networks and properly installed and operated on Bay Networks hardware or other equipment it is originally licensed for to function substantially as described in its accompanying user manual during its warranty period which begins on the date Software is first shipped to Licensee If any item of Software fails to so function during its warranty period as the sole remedy Bay Networks will at its discretion provide a suitable fix patch or workaround for the problem that may be included in a future Software release Bay Networks further warrants to Licensee that the media on which the Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days
55. ribed in Managing Routers Using the HTTP Server IP Multicasting Configuration The following features are new for DVMRP and IGMP Relay in BayRS Version 13 10 For more information about DVMRP and IGMP Relay see Configuring IP Multicasting and Multimedia Services DVMRP BCC Support You can now use the BCC to configure DVMRP globally and on an IP interface and to configure DVMRP tunnels For information about configuring DVMRP using the BCC see Chapter 4 of Configuring IP Multicasting and Multimedia Services DVMRP Policies BayRS Version 13 10 supports DVMRP accept unicast route policies and accept policies as well as both the announce and the ignore functions for DVMRP announce policies earlier versions of BayRS supported only the ignore function for DVMRP announce policies e An accept unicast route policy causes DVMRP to copy the routes you specify from the IP unicast routing table and inject them into the DVMRP routing table You must configure an inject unicast route policy if you are connecting a multicast router running DVMRP to an IGMP Relay device e An accept policy causes DVMRP to filter incoming advertisements e An announce policy governs the propagation of DVMRP routing information 24 301151 C Rev 00 Release Notes for BayRS Version 13 10 For information about configuring DVMRP policies see Chapter 4 of Configuring IP Multicasting and Multimedia Services IGMP Relay An IGMP Relay device is a unica
56. router allows connection of the FEPs using SDLC or LLC LAN to LAN SDLC to SDLC LAN to SDLC and SDLC to LAN connections are supported The FEPs communicate using FID4 data flows FID4 is the SNA protocol format used between two adjacent subarea nodes This protocol format is supported by single switch and dual switch operation of DLSw For information about DLSw see Configuring DLSw Services 22 301151 C Rev 00 Release Notes for BayRS Version 13 10 Domain Name Server DNS Proxy The DNS proxy server is a system solution that lets the router act as a DNS server DNS clients can configure an interface on the router as their DNS server The DNS proxy server on the router has a list of servers to contact on behalf of the client Using the DNS proxy server feature a network administrator can statically configure hosts to use the IP address of the DNS proxy server on the router If DNS servers change or physically move the administrator has to change the list of DNS servers only on the router rather than on each individual client For information about the DNS Proxy Server see Configuring IP Utilities Generic Routing Encapsulation Generic Routing Encapsulation GRE which is defined in RFCs 1701 and 1702 is a generalized protocol that defines a method for encapsulating any payload inside any network layer 3 protocol For BayRS Version 13 10 GRE allows the layer 3 protocol IPX as well as IP to be encapsulated in IP GRE tun
57. s If the number of configured L2TP slots is less than or equal to the number of configured assigned user network addresses the router automatically converts all assigned user network addresses to L2TP IP addresses Upgrading OSPF Configurations When you upgrade BayRS from releases earlier than Version 12 20 there must not be an OSPF MTU interface mismatch If a mismatch exists adjacencies will not form between upgraded routers All the OSPF routers forming adjacencies on a segment broadcast PPP Point to Multipoint or NBMA should have the same OSPF MTU size You can verify the OSPF MTU sizes from Site Manager or the Technician Interface BayRS Versions 12 20 and later comply with RFC 2178 which requires the OSPF MTU size feature Upgrading the BCC Help File The following information updates instructions relating to the BCC Help file mentioned in Upgrading Routers to BayRS Version 13 xx 301151 C Rev 00 3 Release Notes for BayRS Version 13 10 If you received a flash card with the BayRS 13 10 BCC 4 10 image it should also contain the BCC Help file bcc help The BCC looks for this file name as soon as you enter the first help lt option gt command after booting the router using the new Version 13 10 image If the bcc help file is not already on the default volume in the router you must transfer it from the BayRS Version 13 10 software CD to that volume The BCC Help file on the BayRS software CD has the name bcc help
58. ssion Enhancements BayRS 13 10 adds BCC commands for changing the compression mode disabling and reenabling WCP and adding WCP software compression for PPP and frame relay services in several different contexts It also adds descriptions of the show commands for both hardware and software data compression DHCP Server DHCP now implements a DHCP server feature that complies with RFC 2131 The DHCP server manages client IP addresses and interacts with the NetID Server Manager to configure and maintain client address ranges and configuration options For the DHCP server to operate you must first install the NetID Server Manager ona UNIX or NT workstation and configure it to communicate with the DHCP server Typically you install the NetID Server Manager on the same workstation as the one that contains the NetID database For information about DHCP server see Configuring SNMP BootP DHCP and RARP Services DLSw PU Type 4 Device Support DLSw now supports PU type 4 devices PU physical unit is a component of the network that manages and monitors the resources such as attached links and adjacent link stations associated with the node PU type 4 devices are subarea nodes that use network addresses for routing and maintain routing tables that reflect the configuration of the network PU type 4 devices include IBM 3720 3725 and 3745 front end processors FEPs These FEPs provide enhanced SNA services not provided by routers The
59. st router with an interface to a multicast router and interfaces to one or more networks containing network hosts For BayRS Version 13 10 the multicast router can run DVMRP as well as MOSPF A router configured as an IGMP Relay device provides the following group registration services for an IP multicast router e Solicits multicast group membership information by sending IGMP host membership queries to hosts on its attached local networks e Receives host membership reports and unsolicited join messages from hosts on attached networks and forwards them to the attached multicast router e Forwards multicast data to group members on locally attached networks For information about IGMP Relay see Chapter 9 of Configuring IP Multicasting and Multimedia Services IP Security IPsec The Internet poses the challenge of providing a secure means of communicating that is both scalable and interoperable with different security schemes IP Security IPsec is a set of protocols being developed by the IETF to provide secure communication over IP networks These standards are designed to ensure secure private communication for remote access extranet and intranet virtual private networks VPNs IPsec is designed to work flexibly with different encryption algorithms authentication methods and key exchange methods The Bay Networks implementation of IPsec supports the Encapsulating Security Payload ESP protocol which uses the Data Encryption St
60. t recursive verbose all file lt filename gt Show the configuration of the current object only Example show config Show the configuration of the specified object Example show config ip 1 2 3 4 255 0 0 0 Show the configuration without navigation back commands Example show config compact Show any dependent objects configured on this object Examples show config recursive show config compact recursive show config ip 1 2 3 4 255 0 0 0 recursive Show the configuration including all configurable parameters including those set to a default value Examples show config verbose show config recursive verbose show config ip 1 2 3 4 255 0 0 0 recursive verbose Show the total device configuration Examples show config all show config all verbose Save the output of this command to a file Examples show config all file boston config show config all recursive verbose file boston config show config ip 1 2 3 4 255 0 0 0 file boston config BCC Support for Dial on Demand Service You can now use the BCC to configure dial on demand service on your router For information see Configuring Dial Services 20 301151 C Rev 00 Release Notes for BayRS Version 13 10 BGP Configuration The following features are new for BGP in BayRS Version 13 10 For more information about BGP see Chapter 8 of Configuring IP Services Route Flap Dampening The freguent change
61. uits Label Distribution Protocol Statistics gt Protocols gt MPLS gt LDP Sessions LDP sessions Label Distribution Protocol Statistics gt Protocols gt MPLS gt LDP Information label information base MPLS Routing Support The BayRS 13 10 version of MPLS which operates only on the ARE for the BN router has been qualified with the Ericsson implementation of MPLS The Ericsson implementation supports RIP version 2 and static routes For information about MPLS see Configuring ATM and MPLS Services MPOA Enhancements Bay Networks has supported MPOA Server since BayRS Version 12 20 BayRS Version 13 10 contains the following enhancements e IP route table monitoring with MPOA purges used for updates e NHRP support over LANE For information about MPOA see Configuring ATM and MPLS Services 28 301151 C Rev 00 Release Notes for BayRS Version 13 10 PVC Operations and Management The PVC Operations and Management OAM feature provides a mechanism by which ATM devices can receive prompt failure information Traditionally the remote ATM device receives failure information from a non ATM source suchasa routing protocol that operates above the ATM layer This type of notification can take a significant amount of time The PVC OAM feature updates the remote device over the ATM layer decreasing the failure notification to only a few seconds For information about OAM see Configuring ATM and MPLS Services
62. ule with DCM arnpbtenx10 8960 ARN Ethernet and Tri Serial Expansion Module with DCM arnsenet 8832 ARN Ethernet Port Expansion Module arnssync 8736 ARN Serial Adapter Module arnstkrg 8816 ARN Token Ring Expansion Module arntsync 8848 ARN Tri Serial Port Expansion Module 16 301151 C Rev 00 Release Notes for BayRS Version 13 10 Table 5 lists the System 5000 board types Table 5 BCC Board Types System 5000 Modules Technician Interface or MIB BCC Board Type Module ID Description asngbri 2560 Router Quad Port ISDN BRI Net Module atm5000bh 524544 Centillion Multiprotocol Engine denm 1280 Router Dual Ethernet Net Module dmctinm 2944 Router Dual Port MCT1 Net Module dsnmin 1540 Router Dual Synchronous Net Module dtnm 2048 Router Dual Token Ring Net Module ige 1408 5380 Ethernet Router Module igtok 2176 5580 Token Ring Router Module mceinm 2816 Router MCE1 Net Module mmasmbdas 1833 Router Hybrid PHY B FDDI Net Module mmfsddas 1793 Router Multimode FDDI Net Module qsyncnm 1664 Router Quad Port Synchronous Net Module se100nm 2304 Router 100BASE T Ethernet Net Module shssinm 3584 Router HSSI Net Module smammbdas 1825 Router Hybrid PHY A FDDI Net Module smfsddas 1801 Router Single Mode FDDI Net Module Sending BCC Feedback After you use the BCC we welcome your feedback Please visit the BCC Web site at the following URL where you can leave us a message http support
63. unavailable continued 301151 C Rev 00 Release Notes for BayRS Version 13 10 BCC show command Where Documented show ipx Configuring IPX Services show isdn switch Configuring Dial Services show lane Configuring ATM and MPLS Services show mct1e1 show modem Configuring WAN Line Services Configuring Dial Services show mtm unavailable show ntp Configuring IP Utilities show ospf unavailable show ppp Configuring PPP Services show process Using the Bay Comand Console BCC show rmon Configuring RMON and RMON2 show serial Configuring WAN Line Services show snmp unavailable show sonet Configuring ATM and MPLS Services show syslog BayRS Version 13 10 Document Change Notice show system Using the Bay Command Console BCC show tcp Configuring IP Utilities show telnet Configuring IP Utilities show tftp Configuring IP Utilities show token ring Configuring Ethernet FDDI and Token Ring Services show wcp Configuring Data Compression Services 301151 C Rev 00 Release Notes for BayRS Version 13 10 Identifying Board Types Tables 1 through 5 identify the Board Type parameter values displayed by the BCC Use the Board Type column to find in alphabetical order a hardware module inan AN ANH ARN ASN BN or System 5000 router configuration Noles You cannot use BCC commands to configure an X 25
64. upport BayRS supports the following new expansion modules for the ARN router ETS one Ethernet port plus seven serial ports e 7S seven serial ports RS232 V35 RS422 X 21 You cannot use NetBoot on ports 6 7 8 and 9 BCC Support for the FRE2 060E Processor Module with Advanced Compression Coprocessor BayRS 13 10 provides BCC support for the FRE2 060E processor module with advanced hardware compression capabilities that resides in the BN router BCC Support for the FRE 2 060E Processor Module BayRS 13 10 provides BCC support for the FRE2 060E processor module that resides in the BN router Support for 64 MB ATM Routing Engine BayRS 13 10 supports 64 MB ATM Routing Engine ILIs The new AREs offer 64 MB of SRAM and 6 MB of DRAM which allow for greater scalability and performance Table 6 64 MB ATM Routing Engine Specifications Part Number Description AG1304020 64M 6M ARE with OC3 MMF ILI AG1304015 64M 6M ARE with OC3 SMF ILI AG1304016 64M 6M ARE with DS 3 ILI AG1303021 64M 6M ARE with E3 ILI 30 301151 C Rev 00 Release Notes for BayRS Version 13 10 Guidelines for Working with BayRS Version 13 10 Note the following guidelines when using BayRS Version 13 10 These guidelines supplement the instructions in the Version 13 10 documentation set Amendment to Configuring PPP Services You can now configure the following PPP line features using the BCC e Convergence timer e Asy
65. yRS Version 13 10 Table 1 BCC Board Types AN and ANH Modules continued Technician Interface or MIB BCC Board Type Module ID Description ansedsgf 1108 ANH 8 with T1 FT1 1 Ethernet port 2 serial ports and an 8 port Ethernet hub ansedsgi 1051 ANH 8 with ISDN 1 Ethernet port 2 serial ports and an 8 port Ethernet hub ansedsgj 1127 AN ENET 1 Ethernet port 2 serial ports 1 fractional E1 port and an 8 port Ethernet hub ansedsgjx 1137 AN ENET 1 Ethernet port 2 serial ports 1 fractional E1 port and an 8 port Ethernet hub and DCM ansedsgx 1048 ANH 8 with DCM 1 Ethernet port 2 serial ports and an 8 port Ethernet hub ansedsh 1026 ANH 12 1 Ethernet port 2 serial ports and a 12 port Ethernet hub ansedshc 1093 ANH 12 with CSU DSU 1 Ethernet port 2 serial ports and a 12 port Ethernet hub ansedshf 1106 ANH 12 with T1 FT1 1 Ethernet port 2 serial ports anda 12 port Ethernet hub ansedshi 1029 ANH 12 with ISDN 1 Ethernet port 2 serial ports and a 12 port Ethernet hub ansedshj 1125 AN ENET 1 Ethernet port 2 serial ports 1 fractional E1 port and a 12 port Ethernet hub ansedshjx 1136 AN ENET 1 Ethernet port 2 serial ports 1 fractional E1 port and a 12 port Ethernet hub and DCM ansedsi 1027 AN ENET with ISDN 2 Ethernet ports 2 serial ports with 16 MB DRAM ansedsj 1119 AN ENET 1 Ethernet port 2 serial ports 1 fractional E1 port with 16 MB DRAM ansedsjx 1133 AN ENET