Home

Aube Technologies TH147E-P User's Manual

image

Contents

1. protection Off On or Off 15 SOOT ae a OF Over Unoccupied mode temperature 10 5 to 28 C Hid setting 3 TH148ELE P only o CPH Number of cycles per hour 4 4 2 3 4 50r6 1 When pump protection is On the thermostat will activate the heating sys tem for 15 seconds if it has not been activated for the past 24 hours 2 Daylight savings time starts on the last Sunday of March and normal time starts on the last Sunday of October 3 See section 2 5 4 The corresponding cycle lengths are 2 30 min 3 20 min 4 15 min 5 12 min 6 10 min Select the cycle according to the type of heating gas boiler lt 30kW 10 minutes oil boiler 20 minutes Technical Specifications Power supply 2 LR6 1 5V Alkaline batteries Maximum load 5 A resistive 0 95 A inductive 240 VAC Power across UN terminals 20 mA 12 VDC Setpoint range 5 to 28 C Display range 10 to 50 C Display resolution 0 5 C Accuracy 0 5 C Cycle length 10 12 15 20 or 30 minutes programmable Conformity IEC60730 1 Storage temperature 20 to 50 C Dimensions 127 mm x 75 mm x 28 mm TH147E P amp TH148ELE P vV Warranty Aube warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and service for a period of three 3 years from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective or malf
2. 22 00 22 00 to 6 00 Friday L EE l I AAAI 0 2 4 6 8 10 12 14 16 18 20 2224 Comfort x Economy Saturday and 6 00 to 22 00 22 00 to 6 00 Sunday LA_A_A_A_A_JL_A_____IL__A_F_ 0 2 4 6 8 10 12 14 16 18 20 22 24 4 4 Modifying the Schedule ifnot already done set the Comfort and Economy temperatures see section 3 4 Press Pgm The program for Monday will appear and the first period 0 00 a m to 1 00 a m is selected flashes Each period is a one hour interval Note If you wish to use the same program every day press Pgm for 3 seconds to select all the days of the week Press or to advance to the next or preceding period respec tively Select the Comfort or Economy temperature by pressing on the corresponding button X or Repeat steps 3 and 4 as required To modify the program for another day press Pgm until the day is selected and repeat steps 3 to 5 00O 6 Press Exit to exit the programming mode 400 147 016 C 2008 01 08 3 4 Configuration Press the backlight button until the configuration menu appears 3 seconds To go to the next parameter menu item press the backlight but ton 1 second oO e To modify a parameter press 60 4 Repeat steps 2 and 3 if necessary To end press the backlight button until the configuration menu disappears 3 seconds DISPLAY DESCRIPTION DEFAULT SELECTIONS He Time display 12h 12hor24h pp Pump
3. ations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from region to region If you have any questions concerning this warranty please write Aube 705 Montrichard Saint Jean sur Richelieu Quebec J2X 5K8 Canada Technical Assistance For any questions regarding the product installation or operation contact our technical support team at Tel 33 0 1 34 07 99 00 Fax 33 0 1 34 07 99 19 Email advaube comintes com For more information on our products visit us at www aubetech com 400 147 016 C 2008 01 08 4 4
4. aube technologies Introduction The TH147E P and TH148ELE P thermostats can be used to control a forced air system 2 or 3 wires a hot water system with or without pump 2 wires e a millivolt system 2 wires Adjustment Display buttons l Backlight N button XE C Pom Mode e oo0o0o0 Clk Exit IA 7 Comfort Economy Mode selection temperature temperature Program program exit preset preset button Display Appears when the nar setpoint temperature Xk Comfort temperature indicator is displayed C Economy temperature indicator a Temperature SAn eS er or e000 vw Day yo m X Z ri Manual mode Gb l vA cD e LI Automatic mode aT 1 ti riily piitliiiriit_l_ Schedule 0 2 6 10 12 14NI6 18 20 22 24 Heating is On Low battery indicator Unoccupied mode Pump protection Programmable cycle length Battery replacement indicator Backlit display Programming Preprogrammed schedule Temporary bypass Time display 12 h or 24 h TH147E P amp TH148ELE P Installation and User Guide Programmable Thermostats Installation Note The installation must be performed by an electrician 2 1 Removing the Old Thermostat IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK CUT POWER TO THE HEATING SYSTEM Remove the old thermostat to access the wi
5. ion 4 1 TH147E P amp TH148ELE P 2 7 Completing the Installation Once the baseplate and the batteries are installed mount the thermostat on the baseplate Secure the thermostat using the locking screw and install the faceplate Apply power back to the system Basic Functions 3 1 Backlight The display illuminates for 12 seconds when the backlight button or any other button is pressed 3 2 Displaying the Temperature The actual measured temperature is normally displayed To view the setpoint temperature press once on either of the buttons The setpoint along with the icon will be displayed for the next 5 seconds 3 3 Setting the Temperature Press one of the buttons until the desired temperature is dis played 3 4 Comfort and Economy Temperatures The thermostat has 2 preset temperature buttons Comfort 3x temperature e Economy temperature To set the thermostat at the Comfort or Economy temperature press the corresponding preset button The corresponding symbol will be displayed The following table shows the use and the factory setting of each preset button Button Intended use Default setting x Comfort when the occupant is awake and at home 21 q Economy when the occupant is absent or asleep 17 C To modify the Comfort or Economy temperature Set the desired temperature using the buttons Press and hold the appropriate preset butto
6. n until the corre sponding symbol is displayed 400 147 016 C 2008 01 08 2 4 3 5 Control Mode 3 5 1 Manual Use this mode to set the temperature manually To use this mode press Mode to display 4 and set the desired temperature using the buttons or the xx buttons 3 5 2 Automatic Use this mode to set the temperature according to the programmed schedule see section 4 3 To place in Automatic mode press Mode to display amp Temporary Bypass If you modify the setpoint temperature when the thermostat is in automatic mode the new temperature will be used for the next 2 hours Afterwards the thermostat will return to the automatic mode and use its current temperature setting The icon flashes during the bypass 3 5 3 Unoccupied 7H748ELE P only To place the thermostat in Unoccupied mode see section 2 5 When the thermostat is in this mode the unoccupied mode setpoint is used and the icon is displayed Temporary Bypass If you modify the setpoint temperature when the thermostat is in unoccupied mode the new temperature will be used for the next 2 hours Afterwards the thermostat will return to the unoccupied mode setpoint The icon flashes during the bypass 3 6 Low battery Indicator An icon appears when the batteries need replacement This icon will flash for 60 days then the thermostat will wa cut power to the heating system The icon disappears once the batteries are replaced After replacing the ba
7. res 2 Identify and label each wire with the corresponding letter on the wire terminal and remove them from the terminals if necessary strip the end of each wire maximum of 6 mm 2 2 Installing the New Baseplate Choose a location approximately 1 5 m above the floor and on an inside wall Avoid draughty areas top of staircase air outlet etc dead air spots behind doors direct sunlight or areas near concealed pipes or chimneys Remove the thermostat faceplate Loosen the locking screw in order to separate the thermostat from its baseplate the screw cannot be completely removed Gently tilt the thermostat upwards Pass the wires through the opening of the baseplate and secure the baseplate to the wall using the appropriate screws 2 3 Terminal Designations R Power WwW Load X K KK OK CK CK CK X lt Interchangeable faceplates Un Un_ Unoccupied mode input TH148ELE P only Unoccupied mode activated remotely lt x K KY KOK OK OK KX CK CX Xx Automatic daylight savings changeover TH147E P amp TH148ELE P 400 147 016 C 2008 01 08 1 4 2 4 Connecting the Heating System R W NOTE z No polarity to observe L1 12 Load 2 5 Unoccupied Mode Input 7H748ELE P only TH148ELE P has an input that can be used to lower the temperature when the house is
8. tteries re adjust the clock and day see section 4 1 For TH148ELE P model re adjust the date also see section 4 2 The rest of the settings are unaffected when the batteries are removed Programming 4 1 Setting the Clock and Day Press Clk for 3 seconds The hour display flashes Set the hour using 6 Press Clk The minute display flashes Set the minutes using 0 Press Clk The day display flashes Set the day using 60 o000000 Press Exit to exit the programming mode TH147E P amp TH148ELE P 4 2 Setting the Date TH148ELE P only This setting is necessary only if you use the automatic daylight sav ings changeover see section 5 Press Clk for 3 seconds The time setting is displayed YE Ar 05 Set the year using and press Clk to display Mo the month setting eam Set the month using and press Clk to display the date setting Set the day using 90 Press Clk for 3 seconds again The year setting is displayed a3 oo Press Exit to exit the programming mode 4 3 Schedule When the thermostat is placed in automatic mode it switches between the Comfort temperature and the Economy temperature according to the programmed schedule You can set a different pro gram for each day of the week The following schedule has been pro grammed in the thermostat as follows Comfort 2 Economy 6 00 to 8 00 8 00 to 18 00 Monday to 18 00 to
9. unctions Aube shall repair or replace it at Aube s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii call Aube Technical Support at 33 0 1 34 07 99 00 Technical Support will make the determination whether the product should be returned to the following address 10 rue Amp re 95500 Gonesse France or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Aube that the defect or mal function was caused by damage which occurred while the product was in the possession of a consumer Aube s sole responsibility shall be to repair or replace the product within the terms stated above AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCI DENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WAR RANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some regions do not allow the exclusion or limita tion of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE THREE YEAR DURATION OF THIS WARRANTY Some regions do not allow limit
10. unoccupied You can connect an Aube s CT240 telephone controller optional or another remote control system When the thermostat receives a 12 VDC signal it switches to the unoccupied mode where the setpoint programmed for that mode is used see section 5 When the signal is removed the thermostat returns to the previous mode 2 5 1 Connecting to CT240 Connect TH148ELE P terminals UN and UN to O CT240 terminals A and C no polarity to observe DA Da B Un Un A C CT240 2 5 2 Connecting to a Home Automation System nell Connect TH148ELE P terminals UN and UN to a SO 12 VDC circuit as shown no polarity to observe WN a 12 V 2 6 Installing the Batteries 1 Gently pull out the battery cover install the batteries as shown Observe the polarity Re install the battery cover You will hear a clicking sound After the batteries are installed the thermostat performs a series of tests for approximately 5 seconds Afterwards the thermostat displays the temperature It is possible that the displayed temperature is higher than the ambient tempera ture if you are holding the thermostat in your hands Once installed on the wall the thermostat will display the ambient temperature The time and day settings flash to indicate that they must be set see sec t