Home
Aube Technologies TH113 A User's Manual
Contents
1. Technical Specifications Maximum load 0 5 A 24 VAC Heating cycle length 15 minutes Operating temperature 32 F to 122 F 0 C to 50 C Storage 4 F to 122 F 20 C to 50 C Size H W D 124 x 70 x 23 mm 4 89 x 2 76 x 0 91 in Wire gauge 14 to 22 AWG 400 112 000 B 18 1 06 1 1
2. base operates on 15 minute cycles and can be connected to a line voltage load using a relay or directly to a 24 volt device The PB112 024T is compatible with most relays however the following Aube relays are optimized for use with this power base e RT850 solid state relay SSR e RT850T solid state relay SSR with built in 24 V transformer e RC840 electromechanical relay e RC840T electromechanical relay with built in 24 V transformer Supplied Parts One 1 power base Two 2 plastic anchors Two 2 mounting screws Installation Guidelines gt For a new installation choose a location about 1 5 m 5 ft above the floor gt The thermostat must be installed on an inside wall facing the heating system except for floor heating systems gt Avoid locations where there are air drafts top of staircase air outlet dead air spots behind a door direct sunlight or concealed chimney or stove pipes except for floor heating systems Installation Procedure The installation must be carried out by an electrician and com ply with local electrical codes Turn off power to the heating system at the main electrical panel to avoid electrical shock Wire the base according to your application See typical wiring diagrams in sections 4 1 to 4 4 Fora floor heating system installation con nect the floor sensor between the S and R ter minals Secure the base to the wall using the provid
3. TH113 amp TH116 A F AF Owner s Guide Thank you for choosing Aube s non programmable thermostat Your new electronic thermostat is equipped with a microprocessor and proportional integral adaptive PIA temperature control technology for total comfort Depending on the selected model this thermostat has been designed to control A The Ambient temperature using an electric heating system AF The Ambient temperature with Floor temperature limit using a floor heating system to heat the room F The Floor temperature floor heating NOTE This control module must be mounted on a PB112 Series power base alia technologies The thermostat has an On Standby switch making it possible to put the thermostat in sleep mode when its use is no longer required e g summer O Control Module Installation Align the bracket tabs on the control module with the holes located on the power base Follow the same procedure for the TH116 Control module Power base NOTE Keep the thermostat s air vents clean and free from obstructions NOTE The screw cannot be removed completely ap Model Selection switch FOR A AND AF MODELS ONLY At the rear of the control module is a switch that has been factory set to the applicable temperature control NOTE The AF model can be used for all temperature control types A F and AF Floor Note The ambient Sensor sensor is not z operational
4. Y This product is guaranteed against workmanship defects for a one year period following the initial date of purchase During this period AUBE Technologies Inc will repair or replace at our option and without charge any defective product which has been used under normal conditions The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation This warranty cancels and replaces any other manufacturer s express or implied warranty as well as any other company commitment AUBE Technologies Inc cannot be held liable for related or random damages following the installation of this product The defective product as well as the purchase invoice must be returned to the place of purchase or mailed prepaid and insured to the following address Aube Technologies Inc 705 Montrichard Saint Jean sur Richelieu Quebec Canada J2X 5K8 If you have any questions concerning the TH113 or the TH116 thermostat call our technical support team at Phone Montreal area 450 358 4600 Canada U S 1 800 831 AUBE 2823 Fax y 450 358 4650 Email service aubetech com Monday to Friday from 8 30 AM to 5 00 PM EST For more information on our products visit us at www aubetech com 01 08 03 920 113 001 00 1 A d technologies Applications The PB112 024T power base can be used on any TH11x series thermostat with the exception of the TH110 model This low voltage power
5. e notch points to the desired temperature The TH113 and TH116 are equipped with a remote input which allows connection of an optional telephone controller CT240 or any other remote control system When a command signal is received through this input the thermostat automatically lowers its setpoint by 3 5 C The LED lights up to indicate the signal s presence except for GA and GB models Bypass not available for GA and GB power base The TEST button can be used to bypass the signal for a 2 hour period The LED goes off to indicate the bypass NOTE When combined with a GA GB power base the TEST button is used only for GFCI testing The bypass function is not available with these power base models Technical Specifications Models TH113 and TH116 A AF F Setting range 45 F 59 F to 95 F 7 C 15 C to 35 C Potentiometers minimum 41 F to 77 F 5 C to 25 C maximum 59 F to 95 F 15 C to 35 C Accuracy 0 9 F 0 5 C Storage 4 F to 120 F 20 C to 50 C Setpoint Definition Turn the dial to the desired temperature TH113 The dial is located on the front of the control module TH116 The dial is located on the rear of the control module The min position indicates the minimum temperature setpoint 45 F 7 C Temperature dial Test ON kia a Warranty AUBE TECHNOLOGIES INC ONE 1 YEAR LIMITED WARRANT
6. ed D screws and wall anchors Configure the switches located on the control module if any Refer to the user guide Install the control module onto the base Load 89 8989 o2 Z oa Apply power to the heating system 0O00 8 6 Verify the installation by checking that the heating system can be turned on or off using the thermostat PB112 024T PB112 024T Installation Instructions 24 V Low Voltage Power Base 4 1 Single SSR with Built in Transformer RT850T PB112 024T e Cc c W Ww Re R s Electrical Panel Blue Red L2 L1 Black Heater 4 2 Multiple SSRs with External Transformer PB112 024T Electrical CWRS Panel DKY BE L2 VDC 4 External 24 V vac Transformer ON EEEPrPrErErEEErEr COM VDC vac t PIPET ETETE COM Heater RT850 4 3 Electromechanical Relay with External Transformer Electrical PB112 024T Panel z RC840 W Ow R 4 c LJ rT External 24 V 3 Transformer P 7 Heater 4 4 Hot Water Heater Valve Electrical Panel c w S R External 24V Valve Transformer
7. when the switch is set to up Ambient sensor Floor Switch sensor 3 A i O GFCI Test ca amp GB power base only The GFCI monitors the electrical flow for any loss of current if there is any loss the thermostat will cut off power to the heating system We recommend you test the GFCI immediately after installing the control module and once a month thereafter to ensure it is operating properly To test Press the TEST button Successful TEST warn ing light is ON and power to heating system is cut off Unsucessful The TEST warning light is OFF Cut power to heating system from the main power panel and call customer service When successful reset thermostat GSTANDBY ON to power heating system NOTE If the test warning light comes ON during normal operation cut power to heating system from the main power panel and have an electrician verify the installation 2 Temperature Lock TH113 only At the rear of the control module are two potentiometers These potentiometers act like a temperature lock Even when occupants adjust the temperature using the dial on the front rear of the control module the potentiometers override the dial and maintain the temperature within the locked in minimum and maximum range gt A ambient temperature gt F amp AF floor temperature limit Use a flat tip screwdriver to rotate the potentiometers until th
Download Pdf Manuals
Related Search
Related Contents
Electrolux 44070 VI Dishwasher User Manual User- and installation manual Cupido 50, Cupido 70, Optica, Bioptica Manual Nikon Coolpix L16 Robic Robie UV-419 User's Manual Upsolar Installation Manual - version 1.14 - www.solar Yamaha USB Audio Driver for Mac OS X 取扱説明書 Page 1 Page 2 Page 3 Page 4 3各部の名称と働き の緑(電源)ランプ Philips 6890XL Electric Shaver User Manual LCX無線LANシステム Copyright © All rights reserved.